XPD Aligment SoP
XPD Aligment SoP
XPD Aligment SoP
adjustment)
Aligning Dual-Polarized Antennas
Prerequisites
The preceding site commissioning items have been completed at both ends of a microwave link.
The weather conditions at both ends are suitable for outdoor operations, and there is no threat of
rain, snow, fog or other unfavorable conditions that could interfere with the procedure.
Onsite conditions meet the requirements for antennas to work at their given heights, and the
commissioning personnel are trained to work at these heights.
A properly calibrated multimeter is available.
The automatic transmit power control (ATPC) function has been disabled (this function is disabled
by default).
The adaptive modulation (AM) function has been disabled (this function is disabled by default).
Context
NOTE:
The following procedure assumes that the RTN 310s at both ends are installed separately from antennas.
If the RTN 310s at both ends need to be connected directly to an OMT, the OMT should be adjusted
instead of the antenna feed boom.
Procedure
1. Power off the vertically polarized RTN 310s and power on the horizontally polarized RTN 310s
at both ends of the microwave link. Ensure that the antennas at both ends are transmitting
horizontally polarized signals.
2. Adjust the azimuth angle and elevation angle of the antennas at both ends by referring to
Aligning Single-Polarized Antennas, and ensure that the main lobes of the horizontally
polarized signals are aligned.
3. Measure the received signal level (RSL) of the horizontally polarized signals, that is, P1, at the
local end.
a. Use a multimeter to measure the RSL at the RSSI port of the horizontally polarized RTN
310.
b. Calculate the RSL of the horizontally polarized signals, that is, P1, by referring to the
curve diagram delivered with the RTN 310.
4. Adjust the feed boom at the local end, and ensure that the RSL of the vertically polarized
signals reaches the lower threshold (P2).
a. Power on the vertically polarized RTN 310 at the local end.
b. Use a multimeter to measure the RSL at the RSSI port of the vertically polarized RTN
310.
c. Calculate the RSL (P2) of the vertically polarized signals by referring to the curve
diagram in the RTN 310 box.
d. Calculate the XPD1 (XPD1 = P1 - P2).
If...
Then...
Go to 5.
e. Release the feed boom holder slightly, and turn the feed boom slightly until the RSL
reaches the lower threshold and the calculated XPD1 is greater than or equal to 24 dB.
5. At both ends of the microwave link, power off the horizontally polarized RTN 310s and power
on the vertically polarized RTN 310s. Ensure that the antennas at both ends are transmitting
vertically polarized signals.
6. Measure the RSL (P3) of the vertically polarized signals at the local end by referring to 3.
7. Adjust the feed boom at the local end, and ensure that the RSL of the horizontally polarized
signals reaches the lower threshold (P4).
a. Power on the horizontally polarized RTN 310 at the local end.
b. Use a multimeter to measure the RSL at the RSSI port of the horizontally polarized RTN
310.
c. Calculate the RSL (P4) of the horizontally polarized signals by referring to the curve
diagram delivered with the RTN 310.
d. Calculate the XPD2 (XPD2 = P3 - P4).
If...
Then...
Go to 8.
e. Release the feed boom holder slightly, and turn the feed boom slightly until the RSL
reaches the lower threshold and the calculated XPD2 is greater than or equal to 24 dB.
Related Information
In practice, you can align vertically polarized antennas first. If XPD can meet requirements after the
vertically polarized antennas are aligned, you do not need to align horizontally polarized antennas.
Otherwise, you need to go on to align the horizontally polarized antennas.
site A
Site B
SNR[dBm]
XPD
values
from
WebLCT
SNR[dBm]
XPD
values
from
WebLCT
P1 H-pol
P2 V-pol
XPD 1
P3 V-pol
P4 H-pol
XPD 2
The values SNR and XPD values from WebLCT can be extracted directly from the performance
options of the IF boards.