OIL AND GAS SEPARATION PROCESS

Introduction
The well-streams (or well fluids) produced from well platforms may consist of crude oil,
gas, condensates, water and various contaminants. The purpose of the separator is to
split the flow into desirable fractions. An oil/gas separator is a pressure vessel that is
installed either in an onshore processing station or on an offshore platform. Based on
the vessel configurations, the oil/gas separators can be divided into horizontal, vertical,
or spherical separators. In teams of fluids to be separated, the oil/gas separators can be
grouped into gas/liquid two-phase separator or oil/gas/water three-phase separator. In
this paper, the three phase separator is used as the basis for the discussion and
presentation of the Piping and Instrumentation Diagram (P&ID) of an oil and gas
separation process.
The figure below shows a simplified flow diagram of the oil and gas 1 st stage separation
process.

Figure 1: Oil and Gas 1st Stage Separation Process flow Diagram (Simplified)
Inlet temperature is often in the range of 100-150 degrees C. On the example platform,
the well stream is colder due to Subsea wells and risers.

The pressure is often reduced in several stages but commonly, three stages are used,
and these allow controlled separation of volatile components. The purpose is to achieve
maximum liquid recovery and stabilized oil and gas, and separate water. A large
pressure reduction in a single separator will cause flash vaporization leading to
instabilities and safety hazards.
The retention period is typically 5 minutes, allowing the gas to bubble out, water to settle
at the bottom and oil to be taken out in the middle. In the first stage separator, the water
content is typically reduced to less than 5%.
Figure 2 show the Piping and Instrumentation Diagram (P&ID) of the 1 st stage (3-Phase)
separator.

Figure 2: P&ID of an Oil and Gas 1st Stage (3-Phase) Separator

Piping
Piping is a system of pipes used to convey fluids (liquids and gases) from one location
to another. The engineering discipline of piping design studies the efficient transport of
fluid.
1. Inlet Pipe for the Well Fluids

Figure 3: Inlet Pipe Diagram of an Oil and Gas Separation Process


From oil or gas well, well fluids will enter the 1 st stage separator vessel where its
constituent componentsoil, gas, and water will be separated. A gate valve is situated
along the pipeline at the vessels entrance in order to allow or stop the flow of fluid.
Figure 3 shows illustrates the diagram of this pipe flow.

2. Flare System (Gas Section)


When the set pressure inside the separator
vessel exceeded, the relief valve becomes the
"path of least resistance" as the valve is
forced open and a portion of the fluid (gas or
liquid-gas mixture) is diverted through the
auxiliary route. The diverted fluid cis usually
routed through a piping system known as a
flare header or relief header to a central,
elevated gas flare where it is usually burned
and the resulting combustion gases are
released to the atmosphere. Figure at the left
shows the diagram for this system
3. Outlet Pipe for the Separated Gas (Vapor)
Figure 4: Flare System Diagram in an Oil and
Gas Separation Process

The
gas
Figure 5: Gas Outlet Pipe System in Separation Process
that
has
been separated from the well fluid mixture is directed through a pipe which is equipped
with several valves including a pressure valve which by means is an actuator valve. The
actuator valve works hand in hand with a pressure transmitter (PT) and control (PC) in
order to monitor and regulate the pressure of the gas flowing through the piping system.

4. Outlet Pipe for the Separated Oil

Figure 6: Oil Outlet Pipe System in Separation Process

The oil that has been separated from the well fluid mixture is directed through a pipe
which is equipped with several valves including a level valve which by means is an
actuator valve. The actuator valve works hand in hand with a level transmitter (LT) and
control (LC) in order to monitor and regulate the flow of the oil through the piping
system. The same system is applied in the outlet pipe for the separated water. See
Figures 6 and 7 accordingly.

Figure 7: Water Outlet Pipe System in Separation Process

Separator Vessel
Below are figures showing external (Figure 8) and internal view (illustrated and with the
major components) of the separator vessel (Figure 9).

Figure 8: Separator Vessel

Figure 9: Major Components inside the Separator Vessel


At the crude entrance there is a baffle slug catcher that will reduce the effect of slugs
(Large gas bubbles or liquid plugs). However some turbulence is desirable as this will
release gas bubbles faster than a laminar flow. At the end there are barriers up to a
certain level to keep back the separated oil and water. The liquid outlets from the
separator will be equipped with vortex breakers to reduce disturbance on the liquid table
inside. This is basically a flange trap to break any vortex formation and ensure that only

separated liquid is tapped off and not mixed with oil or water drawn in though these
vortices. Similarly the gas outlets are equipped with demisters, essentially filters that will
remove liquid droplets in the gas.

System Control and Instrumentation


Gate Valve with spectacle blind flange

Gate valves are


primarily designed to
start or stop a flow
(in this case the flow of well fluids)
when a straight line
flow of fluid and minimum flow
restriction
are
needed. In service, these valves
are pretty much kept
either fully open, or fully closed.
When turned open, the disc of the gate is completely removed allowing contents to
pass. Although this gives the valve good shut-off properties and is bidirectional, they
cannot be quickly opened or closed and are sensitive to vibration when open.
A spectacle blind is a safety device used to isolate a section of line or piece of
equipment when the line or equipment needs to be inspected or removed from service.
It is different than a valve in that the blind is a permanent or long term isolation device.
One end of the blind will have an opening to allow flow through the pipe during
operation and the other end is solid to block flow during maintenance.
Relief Valve

The relief valve is a type of valve used to


control or limit the pressure in a system
or vessel which can build up for a
process upset, instrument or equipment
failure, or fire. It is designed or set to
open at a predetermined set pressure to
protect pressure vessels and other
equipment from being subjected to
pressures that exceed their design limits.

Normally Closed Valve


Examples of normally-closed valves are sampling valves,
which are only opened while a sample is taken for test.
Other examples of normally-closed valves are emergency
shut-down valves, which are kept open when the system is
in operation and will automatically shut by taking away the
power supply. This happens when there is a problem with a
unit or a section of a fluid system such as a leak in order to
isolate the problem from the rest of the system.

Flange

The flange in oil and gas applications can be a plate or ring to form a rim at the end of a
pipe when fastened to the pipe (for example, a closet flange). A blind flange is a plate
for covering or closing the end of a pipe. A flange joint is a connection of pipes, where
the connecting pieces have flanges by which the parts are bolted together.
Actuators (Diaphragm or Globe)

Actuators are a means by which a valve can be automated so that no human interaction
with the valve package is necessary to cycle the valve. Actuators can be remotely
operated and can act as shutdown mechanisms in case of an emergency situation,
wherein human interaction can be dangerous.
The diaphragm-style actuator includes a rubber diaphragm and stem in a circular steel
housing. This style of actuators is ideal for valves requiring shorter travel, such as
diaphragm valves and globe valves.

Reducer / Expander

Generally, the control valve size is smaller than the corresponding line size. This change
in diameter should be clearly indicated in the P&ID with reducer and expander. The
former is the component in a pipeline that reduces the pipe size from a larger to a
smaller bore (inner diameter). While the latter on the other hand, expands the pipe size
from a smaller to a larger bore.
Ball Valve (Normally Closed)

An increase in fluid pressure to the actuator is required to cause this valve to open.

Pressure Transmitter

A pressure transmitter senses a pressure and outputs a proportional current signal


which is then transmitted to a monitor or controller

Pressure Controller (mounted in the control room)

Pressure controller receives data reading from pressure transmitter, compared that
reading to a programmed setpoint, and signals a control element (in this case, an
actuator valve) to either close or open depending on the corrective action needs to be
taken.

Level Transmitter

Level transmitter provides an electrical output proportional to the well fluid level in the
separator vessel. It may provide an output upon reaching a specified value (point level)
or repeatedly after each measurement (continuous level).

Level Controller (mounted in the control room)

It regulates the level of the well fluids by processing the reading it receives from the
level transmitter and then, compares the reading from a specified setpoint before it
gives signal to the actuator valves which will either open or close depending on the
corrective action that needs to be taken.