NBG 12LR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

September 17, 2001

DN-6840 F-710

NBG-12LR and NBG-12LRA

Dual-Action Agent Release Stations


Section: Releasing Panels

California
State Fire
Marshal

GENERAL
The NBG-12LR and NBG-12LRA are Agent Release Stations designed for use with NOTIFIER Fire Alarm Control
Panels with releasing capabilities and RP Series Releasing Systems.

FEATURES

7150-0028:199
S692

Approved

Non-coded, dual action operation.


Made with durable polycarbonate.
Optional surface backbox.
NBG-12LRA includes:
" Abort switch.
" Power-on indication.
" Released indication.
" Manual release (dual-action).
NBG-12LR includes:
" Dual-action release only.

APPLICATIONS
The NBG-12LRA and NBG-12LR are ideal for areas such
as clean rooms and computer rooms where a chemical
agent is used to extinguish a fire.
NBG-12LRA

Agent release station with abort switch,


Release LED, Normal LED.

NBG-12LR

Dual-action agent release station.

SBA-10

Surface backbox for NBG-12LRA.

SB-10

Surface backbox for NBG-12LR.

NOTIFIER

6840RA12.wmf

PRODUCT LINE INFORMATION

Dual-Action NBG-12LRA
(shown activated)
This document is not intended to be used for installation purposes. We try to keep our
product information up-to-date and accurate. We cannot cover all specific applications or
anticipate all requirements. All specifications are subject to change without notice.
For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118
12 Clintonville Road, Northford, Connecticut 06472
DN-6840 09/17/01 Page 1 of 2

6840LR12.wmf

WIRING

Dual-Action NBG-12LR
NOTIFIER

6840wir1.wmf

*NOTE: Mount End-of-Line Resistor on the last unit.


*Mount 4.7K ELR on the last unit when abort switch and manual release switch are
connected to control panel circuits. Mount 47K resistor on last unit when abort switch and
manual release switch are connected to monitor module or control module. Refer to
control panel manual for the listed ELR. Refer to the following documents when connecting to the control panel: S-500/TC-2 (P/N 15019/15023); S-5000/TCM-2 (P/N 15583/
15805); RP-1002 (P/N 15151); AFP-200 (P/N 15511), AFP-400 (P/N 50253).

DIMENSIONS, BACKBOXES

12345678901234
12345678901234
12345678901234

12345678901234
Normally
Open
12345678901234
12345678901234
12345678901234
Abort
Switch
12345678901234
12345678901234

6840wir2.wmf

6840sbba.wmf

NBG-12LRA (rear view)


Agent Release Pull Station
Page 2 of 2 DN-6840 09/17/01