DI28
DI28
DI28
CIRCUIT DESCRIPTION
The ATF temperature sensor converts fluid temperature value into a resistance value which is input into the
ECM.
DTC No. DTC Detecting Condition Trouble Area
Either (a) or (b) is detected momentary within 0.5 sec. when
neither P0712 or P0713 is not detected
P0710
(a) ATF temperature sensor resistance is less than 79 Ω.
(b) ATF temperature sensor resistance is more than 156 kΩ. Open or short in ATF temperature sensor circuit
ATF temperature sensor
ATF temperature sensor resistance is less than 79 Ω. for 0.5
P0712 ECM
sec. or more
ATF temperature sensor resistance is more than 156 kΩ. for
P0713
0.5 sec. or more
WIRING DIAGRAM
ECM
ATF Temperature
Sensor
2 1 19 26
A7 A7
Y–R
E8 E8 THO*1
*2 *1 THOC*2
L–B 11 18
E8 E7 E2
*2 *1
*1: 3RZ–FE
*2: 5VZ–FE
D10857
INSPECTION PROCEDURE
PREPARATION:
Remove the ATF temperature sensor.
CHECK:
Measure resistance between terminals of ATF temperature
sensor at 20 °C (68 °F) and 110 °C (230 °F).
20°C (68°F) and OK:
110°C (230°F) Resistance (Approx.):
20 °C (68 °F): 12.1 kΩ
Q07637 110 °C (230 °F): 790 Ω
OK
2 Check harness and connector between ATF temperature sensor and ECM
(See page IN–28).