DI–487

DIAGNOSTICS – AUTOMATIC TRANSMISSION (A340E, A340F)


DIB1F–01

DTC P0710 Transmission Fluid Temperature Sensor ”A”


Circuit

DTC P0712 Transmission Fluid Temperature Sensor ”A”


Circuit Low Input (Onry for 5VZ–FE)

DTC P0713 Transmission Fluid Temperature Sensor ”A”


Circuit High Input (Onry for 5VZ–FE)

CIRCUIT DESCRIPTION
The ATF temperature sensor converts fluid temperature value into a resistance value which is input into the
ECM.
DTC No. DTC Detecting Condition Trouble Area
Either (a) or (b) is detected momentary within 0.5 sec. when
neither P0712 or P0713 is not detected
P0710
(a) ATF temperature sensor resistance is less than 79 Ω.
(b) ATF temperature sensor resistance is more than 156 kΩ.  Open or short in ATF temperature sensor circuit
 ATF temperature sensor
ATF temperature sensor resistance is less than 79 Ω. for 0.5
P0712  ECM
sec. or more
ATF temperature sensor resistance is more than 156 kΩ. for
P0713
0.5 sec. or more

WIRING DIAGRAM

ECM
ATF Temperature
Sensor
2 1 19 26
A7 A7
Y–R
E8 E8 THO*1
*2 *1 THOC*2

L–B 11 18
E8 E7 E2
*2 *1

*1: 3RZ–FE
*2: 5VZ–FE
D10857

2003 TOYOTA TACOMA (RM1002U)

Author: Date: 749


DI–488
DIAGNOSTICS – AUTOMATIC TRANSMISSION (A340E, A340F)

INSPECTION PROCEDURE

1 Check ATF temperature sensor.

PREPARATION:
Remove the ATF temperature sensor.
CHECK:
Measure resistance between terminals of ATF temperature
sensor at 20 °C (68 °F) and 110 °C (230 °F).
20°C (68°F) and OK:
110°C (230°F) Resistance (Approx.):
20 °C (68 °F): 12.1 kΩ
Q07637 110 °C (230 °F): 790 Ω

NG Replace the ATF temperature sensor.

OK

2 Check harness and connector between ATF temperature sensor and ECM
(See page IN–28).

NG Repair or replace the harness or connector.

OK

Check and replace the ECM


(See page IN–28).