CT VALVE

Proven Performance in High Speed Gas Compressors

For gas gathering and gas processing compressors


The challenges that high speed compressors pose to valve designers are that they must withstand higher impact rates and resist the sticking effect that occurs when liquids are caught between the sealing elements. The CT Valve uses a webbed valve plate design. The valve plate is made from a high-temperature, highstrength polymer. The spring load is distributed evenly through coil springs located around the outer circumference of the plate. All springs conform to the same spring load which reduces service costs significantly. The valve has been a phenomenal success in the field. Over 300,000 CT valves are operating successfully in gas gathering and gas process compressors, allowing compressor speeds to match the latest engine technology for remote field applications. Recommended operating conditions
Speed (RPM) Max. Working Pressure (psi) Max. Differential Pressure (psi) Compression Ratio Maximum Valve Lift (inches) 1800 5000 2200 <3.5 0.110

High speed compressors require a radically different compressor valve design. The CT valve offers highspeed compressors the same reliable operation and maintenance costs as lower speed units.

To prevent stiction, a wafer plate containing inflexions, is positioned against the guard. The sticking effect is virtually eliminated through the use of this wafer and the flexibility of the non-metallic plate. In the field, the CT Valve has proven its advantages; namely good flow characteristics, high reliability, long life, and simple maintenance.

Special designs and application constraints may alter valve operating parameters. HOERBIGER will optimize the design for special applications.

Plate motion of a suction valve. If valves are over lubricated, it can delay their closure. The sticking effect normally encountered with liquids and lube oil is detrimental at high speed. The CT valve is designed to prevent failure due to oil stiction.

Why choose the CT Valve?

Durable plate materials made from high temperature, high strength polymer that holds up under high, localized stress. It effectively absorbs foreign particles and its flexibility allows it to cope well with the sticking effects caused from liquids and oils.

Oil stiction eliminated with the combination of a flexible, non-metallic valve plate and this wafer plate resting against the retainer. It substantially improves the separation of the plate during valve closure.

Ideal valve dynamics due to the positioning of the coil springs on the outer perimeter. Valve motion is stable with no valve plate wobble. Spring load is evenly distributed which reduces the effects of the opening and closing impacts forces.

Summary Benefits
Excellent flow efficiency for low horsepower consumption per cubic foot delivered Long life even in difficult and contaminated conditions Operates well in lube and non-lube conditions Performs in a wider range of operating conditions

HOERBIGER CORPORATION OF AMERICA, INC. ISO 9001 Registered 3350 Gateway Drive Pompano Beach, FL 33069-4841 Tel: (954) 974-5700 Fax (954) 974-0964 E-mail: mail@hoerbigercorp.com Regional Service Headquarters - HOERBIGER SERVICE, INC., and HOERBIGER (Canada), Ltd. 25057 Anza Drive Santa Clarita, CA 91355 Tel: (661) 257-2888 Toll-Free in CA: (800) 321-3163 Fax: (661) 257-1823 E-mail: hwnrsc@hoerbigercorp.com 77 McCullough Drive, Bay #2 New Castle, DE 19720 Tel: (302) 322-5090 Fax: (302) 322-5680 E-mail: hnernc@hoerbigercorp.com 5405 Consulate Plaza Drive Houston, TX 77032 Tel: (281) 442-2497 Toll-Free: (800) 888-8803 Fax: (281) 442-5926 E-mail: hgcrho@hoerbigercorp.com 330 Brunel Road Mississauga, Ontario L4Z 2C2 Tel: (905) 568-3013 Fax: (905) 568-2407 E-mail: hcl@hoerbigercorp.com 2828 South Utah Avenue Oklahoma City, OK 73108 Tel: (405) 681-3100 Toll-Free: (800) 678-6118 Fax: (405) 681-6519 E-mail: hmcroc@hoerbigercorp.com #108, 10919-96 Avenue Grande Prairie, Alberta T8V 3J4 Tel: (708) 532-1367 Fax: (708) 539-4931 E-mail: hclgp@hoerbigercorp.com

www.hoerbiger-compression.com

Valve Design CT High Endurance Valve with Non-Metallic Valve Plates For High Piston Velocity Applications on Lubricated Air and Gas Compressors
VALVE TYPES: 64 75 88 100 116 127 CET CFT CFT CGT CGT CGT 137 148 158 169 179 CHT CHT CJT CJT CKT

This newest valve design is a development to cope with conditions in the latest high speed Air and Gas cylinders (piston velocities of up to 6 m/s). The design is available with non-metallic valve plates only. It uses a unique steel cushion plate to enhance the life of the valve plate. On valve types 116CGT and larger, coil springs are positioned on the outer perimeter of the plate to cushion the opening and closing motion and to stabilize the plate against wobbling. A slightly curved wafer plate located between guard and cushion plate adds not only an additional dampening element but prevents damaging sticking of plates in lubricated service. The valve is designed with flow efficiency in mind, and seat and guard areas are liberal and balanced with the increased free lift areas. This is a true "long life - high performance" valve available in sizes up to 190 mm diameter. Every HOERBIGER valve is adaptable to existing pocket dimensions and designed to attain the optimum valve lift, spring load, plate thickness and total valve height, based on the operational data of the individual compressor cylinder.

DISCHARGE VALVE ASSEMBLY


spring load wafer spring

total valve lift h +h 2 1

1 2 3 4 5 6 7 8

Valve seat Guide ring Valve plate Cushion plate Closing springs Wafer plate Guard Stud

h1

h2

FIRST IN QUALITY AND DESIGN


HOERBIGER VENTILWERKE GMBH
Braunhubergasse 23 P.O. Box 91 A-1110 Vienna (Austria) Phone (1) 74004-0 Fax (1) 7434222-222 Internet http://www.hoerbiger.com E-mail office@hvw.hoerbiger.com