Inert Gas Generator Specification #Igg-8000 SIZE 8000

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

DETEGASA TECHNICAL SPECIFICATION

INERT GAS GENERATOR IGG-8000

INERT GAS GENERATOR SPECIFICATION N IGG-8000 SIZE 8000

AUTONOMOUS GENERATOR SIZE 8000 NM3/H.


201.1. CHARACTERISTICS Model Capacity Delivery pressure Discharge temperature IGG-8000 8000 Nm3 /H 1500 mm.w.g. 5 degrees C. above sea water inlet temperature.(Max. 32C).

Gas Composition.Nitrogen (N2) Sulphur Oxides (SO2+SO3) Hydrogen (H2) Dewpoint 84%. 100 PPM. Max. 100 PPM. Max. 100% Saturated Oxigen (O2) CO Inert trace gases Soot 2 - 4%. 150 PPM. Max. Balance. 0 (on Bacharach scales)

This unit is also able to deliver the same amount of air for gas freeing with the same dewpoint.

DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, S.A. (D.E.T.E.G.A.S.A.) Address: CTRA. CASTRO / MEIRAS, VALDOVIO, 15550 LA CORUA, SPAIN P.O. BOX: 566 - 15480 EL FERROL - (LA CORUA) - SPAIN PHONE: +34-981-494000 FAX: +34-981-486352

E-MAIL: WEB:

detegasa@jet.es admin@detegasa.com www.detegasa.com

DETEGASA TECHNICAL SPECIFICATION

INERT GAS GENERATOR IGG-8000

201.2 Fuel

SUPPLY DATA Marine Diesel Oil. 70 Degrees C. Min. Inlet Pressure Consumption 0,6 m WC. 625 Kg/hr.

Flashpoint Instruments air.Quality Supply pressure Electricity.Power supply 2 x 100% blower - Oil pump - Controls KW

Free of dirt, oil and water. Max. 7 Kg/cm2. Supply System. 440V - 60Hz - 3PH. rating HP/actual KW ratingHP/actual KW 0,6 Kw.

Capacity Min. 5 Kg/cm2.

0,3 Nm3/h.

Control supply 200/112 3/1.8

220V-60Hz-1PH.

Cooling water for combustion chamber and scrubber.Consumption Inlet pressure 700 m3/h. 2,3 Kg/cm2. Max. 1,2 Kg/cm2. Min. Outlet pressure Combustion air.Inlet temperature Average pressure 40 degrees C. Max. 760 mm. mercury. Relative humidity 90% Max. 0,6 m WC. or less. Quality Inlet temperature 5 mm. mesh filtered. 32 degrees C. Max. 0 degrees C. Min.

Cooling water for deck water seal.Consumption 10 m3/h. Quality Mesh filtered.

201.3. COMBUSTION CHAMBER. TYPE Construction.Material Enclosure Cooling Flow bricklining Elements.DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, S.A. (D.E.T.E.G.A.S.A.) Address: CTRA. CASTRO / MEIRAS, VALDOVIO, 15550 LA CORUA, SPAIN P.O. BOX: 566 - 15480 EL FERROL - (LA CORUA) - SPAIN PHONE: +34-981-494000 FAX: +34-981-486352

HORIZONTAL.

stainless steel 316L two concentrical pipes forming a cooling water jacket. by circulating seawater Distribute and controlled to avoid scaling or hot spots. No briclining is necessary in order to avoid maintenance

E-MAIL: WEB:

detegasa@jet.es admin@detegasa.com www.detegasa.com

DETEGASA TECHNICAL SPECIFICATION

INERT GAS GENERATOR IGG-8000

Seawater low level switch Pilot and main burner High security U.V. cell. Sight glass. Air supply The pilot burner incorporates atomization nozzle and ignition electrodes to ignite the Air D.O. mixture. provided with air flow for cooling and cleaning purposes. provided with air flow for cooling and cleaning purposes. to pilot and main burner for combustion.

201.4. MAIN BURNER. Connection type nozzles combustion head Capacity flanged to the top of the combustion chamber high turbulence high pressure for D.O. atomization fitted with deflectors for a perfect mixing of air and D.O. Either of fixed flow or variable flow with a turn-down capability of 1:3.

201.5. SCRUBBER TYPE Description.The inert gas coming from the combustion chamber has a high temperature and high SO2 contents. Cooling/scrubbing section the gases are cooled down and washed by means of spray nozzles The gases pass through the outer side of the scrubber following a helical path where they are washed again and most of SO and SO2 are eliminated. Demister Separates the water droplets as the inert gas is leaving the generator. Made of polypropilene net and the casing is stainless steel AISI 316L. Accesories.Spray nozzles. Seawater high level switch. Inspection Door. Necessary connections. HORIZONTAL. MATERIAL Stainless Steel 316L.

DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, S.A. (D.E.T.E.G.A.S.A.) Address: CTRA. CASTRO / MEIRAS, VALDOVIO, 15550 LA CORUA, SPAIN P.O. BOX: 566 - 15480 EL FERROL - (LA CORUA) - SPAIN PHONE: +34-981-494000 FAX: +34-981-486352

E-MAIL: WEB:

detegasa@jet.es admin@detegasa.com www.detegasa.com

DETEGASA TECHNICAL SPECIFICATION

INERT GAS GENERATOR IGG-8000

211

OPERATION OF THE SYSTEM.

COMBUSTION - CHAMBER PRESSURE - CONTROL SYSTEM.In order to have a good combustion with a constant quantity of oxigen it is very important to maintain a constant pressure inside the combustion chamber independent of pressure variations in the ships distribution system. For this purpose we include in the system the inert gas generator pressure-control valve. (Item 107) of flow Diagram. DECK MAIN PRESSURE CONTROL.The pressure in the inert gas main is controlled by venting part of the inert gas through the excess gas control valve. (Item 118). The position of this valve is automatically controlled by the excess gas controller installed in the cargo control-room panel and thus the pressure in the inert gas main is also controlled. CAPACITY CONTROL.The inert gas generator can be designed to produce either a variable amount of inert gas (in order to match the inert gas generator output with the demand), or a fixed amount. If of Variable flow, the capacity control is achieved by adjusting the amount of fuel-oil and combustion air by means of a mechanical linkage in the burner, controlling the amount of air an D.O. The amount of air is adjusted in the burner itself by moving the servo in such a way that the air passage is changed. There is also a mechanical linkage to change the fuel-oil nozzles as the quantity of air is changed. CONTROL OF OXYGEN CONTENT.In our supply an O2 analyzer with continous reading and alarm will be included. Also one O2 recorder is included in our scope of supply. There will be two alarms, low and high O2 content. The high alarm protects the tanks atmosphere against high O2 contents and the low alarm protects the unit against under stoichiometric combustion. The alarm condition will not stop the generator, so the operator can adjust the equipment to correct the O2 content. When the O2 content is too high the inert gas is purged to the atmosphere.

DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, S.A. (D.E.T.E.G.A.S.A.) Address: CTRA. CASTRO / MEIRAS, VALDOVIO, 15550 LA CORUA, SPAIN P.O. BOX: 566 - 15480 EL FERROL - (LA CORUA) - SPAIN PHONE: +34-981-494000 FAX: +34-981-486352

E-MAIL: WEB:

detegasa@jet.es admin@detegasa.com www.detegasa.com

DETEGASA TECHNICAL SPECIFICATION

INERT GAS GENERATOR IGG-8000

800 S S

STANDARD SCOPE SUPPLY. Engineering. Inert Gas Generator according to the specification and including the following: . Combustion chamber . Refrigeration Jacket. . Scrubber. . Main and pilot burners. . Demister. . Spray nozzles. . Instrumentation. . D.O. Pumps. . High and low level switches One skid containing 2 fans 100% capacity each, including: . . . Electric motors. Couplings. Antivibration foundation.

S S S S S S S S

Two air fan discharge valves. Two flexible joints for fan discharge pipes. One O2 fixed analyzer. One IGG pressure regulating valve. (Item 107). One inert gas purge to atmosphere valve (Item 118). One inert gas deckmain pressure regulating valve.(Item 119). One safety valve (For deck installation upstream of deck water seal).(Item 145). One Deck water seal including the following elements: . Heating coil. . Flow switch. . Low level switch. . Demister. One inert Gas non - return valve. (Item 131). One inert Gas deck main isolation valve. (Item 132). One P/V. Breaker. One Main control Console "A" located in I.G.G. Room. One Auxiliary control Panel "D" located in cargo control Room. Instrument in navigation bridge Console E. One Pneumatic Panel "B" located in I G G Room. Instrumentation external to control panels, including all the control elements that would be required for the correct operation of the system.

S S S S S S S S

DRAWING LIST FLOW DIAGRAM (4 PAGES) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IGG-000G-F01I PNEUMATIC FLOW DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IGG-000G-N01I INERT GAS GENERATOR GENERAL ARRANGEMENT . . . . . . . . . . . . . . . . . . . . . IGG-000G-G01I PRESSURE VACUUM BREAKER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RPV-000G-G01I DECK SEAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SC-000G-G01I

DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, S.A. (D.E.T.E.G.A.S.A.) Address: CTRA. CASTRO / MEIRAS, VALDOVIO, 15550 LA CORUA, SPAIN P.O. BOX: 566 - 15480 EL FERROL - (LA CORUA) - SPAIN PHONE: +34-981-494000 FAX: +34-981-486352