Интерфейсные модули 2012
Интерфейсные модули 2012
Интерфейсные модули 2012
4
Full Line Catalog, Volume 4
Edition: 2012
WAGO Registered Trademarks
CAGE CLAMP
CAGE CLAMP
@
POWER CAGE CLAMP
FIT CLAMP
PUSH WIRE
TOPJOB
TOPJOB
@
WINSTA
WAGO
X-COM
X-COM
@
JUMPFLEX
TO-PASS
ProServe
EPSITRON
picoMAX
-SYSTEM)
Patchboard Systems
Terminal Strips
PUSH WIRE
Telecontrol Technology
loousit|o| Sw|ic|os, PERSPECTO
MINI Connectors
WINSTA
MIDI Connectors
WINSTA
MAXI Connectors
WINSTA
RD Cable Assemblies
WINSTA
KNX Connectors
WINSTA
8-Channel Adapter
857 Series
0
4
All Applications
Sockets for Miniature Switching Relay /
Optocoupler
788 Series
Pluggable Function Modules
286 and 289 Series
Sockets with Industrial Relay
858 Series
Relay Modules and
Optocoupler Modules
859 Series
Relay Modules in
DIN-Rail Mounted Enclosure
789 Series
0
5
Relay socket with pluggable
miniature switching relay
Relay module with pluggable
miniature switching relay
Transducer
Pluggable function modules
Pluggable signal conditioning modules
Pluggable function modules
Nowadays when equipment is designed
many scenarios need to be considered.
Some of which are user and maintenance
friendly, limited budgets, safety, availabi-
lity, space requirements and simplicity in
design and usage.
WAGO AUTOMATION offers interface
modules in various shapes and sizes to
overcome any of the restraints posed by
space requirements.
This enables any demands and needs to
be fulfilled using these different designs,
such as pluggable function and interface
modules, relay and optocoupler modules,
etc.
286 / 786 Series Pluggable Function
Modules
The terminal blocks for pluggable modu-
les offer the greatest degree of flexibility
and maintenance-friendly service.
The terminal block for pluggable modules
is mounted on the carrier rail and wired
like a normal terminal block.
If service is required, this element can be
replaced in one step, without having to
deal with the system wiring. This saves
space and additional wiring effort.
788 Series Relay Sockets with
Pluggable Miniature Switching Relay
The WAGO Series 788 relay socket
forms an excellent basis for switching
applications using pluggable miniature
switching relays (1 or 2 changeover
contacts) in industrial and process auto-
mation.
In order to cover all application areas
with one product family, it is intended to
offer five different groups for the trans-
ducers alone: these include fixed and
configurable isolating amplifiers, passive
isolators, power supply isolators (also for
HART applications), signal duplicators
and temperature transducers for Pt100
and thermocouples.
The optocoupler and relay modules
are ideal additions to a comprehensive
function module program, allowing any
required functions to be implemented in a
control cabinet by means of a pluggable
module system. Large enclosures of the
Series 786 are available for more com-
plex functions, such as transducers.
In addition to its compact design
15x53x86mm (W x H x D), the relay
socket also stands out thanks to a number
of user-oriented features, with the asso-
ciated benefits for the user.
The lever facilitates relay replacement
even when the relay sockets are placed
close to each other.
The sockets can be ordered as complete
components including relay and status
indication or as a single component.
857 Series Transducers and
Relay Modules
The new 6mm-wide WAGO isolation
amplifiers and transducers not only share
a common profile, but in addition one
in line jumper can be used to connect
the supply voltages, etc, to all modules,
doing away with the need to wire each
connection. The smaller relay modules
also fit perfectly in this scenario. The
pluggable relays can simply be replaced
from the top.
0
6
Relay modules in DIN-rail-mountable enclosure DIN-rail-mountable modules - relay modules
Relay socket
Relay module
Optocoupler module DIN-rail-mountable modules - relay modules EnOcean radio receiver in DIN-rail-mountable
enclosure
789 Series Relay Modules in
DIN-Rail-Mountable Enclosure
The range of uses for the WAGO lat-
ching relays and switching relays of
Series 789 spans from simple lighting
controls in building services, such as in
construction of apartments, hotels, office
buildings or parking garages, etc., up to
installations in industrial control cabinets.
The 17.5mm-wide design in series bay
enclosures is particularly well-suited for
installation in distribution boards and
meter mounting boards.
The series bay enclosures are used for
installation of other electronics devices
having a large scope of functions and
higher switching capacities; these come
in sizes of
2 module spaces (35mm) and
4 module spaces (70mm).
PCB terminal blocks and connectors
from the extensive WAGO program can
be installed in the enclosures to obtain
customized development of interface
components.
Installation is quick and
reliable on the 35mm carrier rail.
287 / 288 Series DIN-Rail-Mountable
Modules - Relay Modules and Sockets
The relay and PLC interface modules in
the mounting socket that can be fitted
on carrier rails ensure quick and easy
linking of signals from periphery devices.
The fully wired modules, with up to 16
high-performance relay outputs, provide
for direct switching of actuators and other
coupling elements in the field.
The requisite free-wheeling and reverse
voltage protection diodes are also inte-
grated to ensure a long service life of the
products.
Other interface modules available as:
Multiple modules with plugged relays
that are easy to replace, without affecting
existing wiring.
859 Series Relay Modules and
Optocoupler Modules
The Series 859 is a complete product
series that is ideal for the interface level
in any industrial application, thanks to the
wide range of relays and optocouplers.
These units excel in tight spaces, thanks
to their narrow 6mm design. Simple
commoning at the control and load side
enables quick and easy looping through
of common input and output potential.
Its robust design and the shock-proof
CAGE-CLAMP
connecting technology
used ensures continuous and uninterrup-
ted operation of any kind of system.
0
7
WAGO Transducers and Relay Modules
JUMPLFEX
, 857 Series
The perfect match of housing and elec-
tronics is the key to a highly successful
device. This is exactly what has been
achieved by WAGO with the transducers
and relay modules of the 857 Series.
Analog systems technology Basics
Problems can arise in signal processing
in industrial systems of analog standard
signals (such as 0-10V or 0-20mA) which
can have an adverse effect on overall
fault-free signal processing. Problems
such as potential differentials arising
from interlinked measuring circuits can
be efficiently prevented using WAGO
transducers, with their associated electri-
cal isolation.
Decoupling (Isolation) methods
A basic distinction is made between
active and passive isolation.
Active isolation
Depending on the design and model in
use, devices are available that incorpo-
rate electrical 3-way isolation. 4-way iso-
lation is provided in a signal duplicator.
This means that all inputs, outputs and
supply circuits are electrically isolated
from one another with a 2.5 kV proof
voltage.
This ensures that the greatest possible
safety and reliability is achieved for the
system and any devices connected to the
system. For 3-way isolation provides for
electrical isolation between the transduc-
ers and the control system and between
the control system and the control ele-
ments.
At the input side the devices required
active signals, i.e., the sensor signal is
generated by a dedicated supply volt-
age.
These devices provide a filtered and
amplified signal at the output side.
Passive isolation
A passive isolator draws power for signal
transmission from the input circuit. In this
case, the sensor must supply a power
level adequate for the device and must
also drive the working resistance.
As a result, it must be ensured that the
current-driving power of the sensor is suf-
ficient to drive the maximum current of
20mA via the passive isolator (with the
device-specific voltage drop), as well as
the working resistance.
This can be calculated using the follow-
ing equation:
US UE = UV + 20 mA x RB
Typical equation for a passive isolator
(857-451) for a 20mA signal.
US UE = 2.0 V + 20 mA x 600
US UE = 14 V
Temperature measuring techniques
Resistance thermometers, such as Pt100
sensors, alter their resistance level as a
function of temperature. For example,
a rise in temperature will result in an
increase in the resistance level. This
reistance level is registered by the JUMP-
FLEX
transducer
can be configured for parameterization,
commissioning and diagnostics of field
devices using WAGOframe, a software
based on the FDT/DTM standard.
The WAGOframe FDT frame applica-
tion provides a wizard, which simplifies
the operation of components, such as
WAGO JUMPFLEX
product family is
rounded out by the relay modules that fit
perfectly with the transducers.
A logical enclosure concept with options
for linking all levels offers a variety of
synergy and cost-savings potential. This
allows for efficient optimization of instal-
lation efforts.
The pluggable relays can be replaced
quickly and easily when required.
For further information about the relays
go to pages 10 - 12.
Type of
sensor
Thermocouple
materials
Measuring range
J *) Fe-CuNi -210 C ... +1200 C
K *) NiCr-Ni -200 C ... +1372 C
E *) NiCr-CuNi -200 C ... +1000 C
N *) NiCrSi-NiSi -200 C ... +1300 C
R *) Pt13Rh-Pt +250 C ... +1768 C
S *) Pt10Rh-Pt -50 C ... +1664 C
T *) Cu-CuNi -200 C ... +400 C
B *) Pt30Rh-Pt6Rh +250 C ... +1820 C
C 0 C ... +2320 C
*) Thermocouples based on IEC 584 / EN 60584
Other thermocouples available upon request.
1
2
3
4
3-wire
1
2
3
4
4-wire
0
9
WAGO Relay Modules.
The professional interface
between electronics and peripheral
equipment.
Even in modern automation systems,
electromechanical relays guarantee
a safe connection between process
control systems and process and
signalling systems. They provide:
a high isolation level between input
and output circuit
ability to match different signal levels
signal amplification and/or signal
multiplication, especially for different
potentials in the input and output
circuits.
Modernized relays also offer
the following advantages:
unaffected by electromagnetic fields
and surges
high short-term overload capacity for
the input and output sides
small switching power losses
a module for switching of AC or DC
WAGO AUTOMATION offers a
complete range of relay modules that
provide these functions for a wide range
of applications.
Depending on the function and
operating conditions, the relay modules
are available with different contacts, con-
tact materials, housings and shapes.
The following relay types are also
available: bistable switching relays, time-
delay relays, current pulse switching and
safety relays with force-guided contacts.
AC versions of select relays equipped
with series connected rectifiers
(refer to the wiring diagrams) can be
triggered with AC and DC at the stated
nominal voltage.
The free-wheel function is in this case
actuated by the rectifier.
In order to guarantee a safe operation it
has to be observed that residual volta-
ges due to cable capacitance in case of
long connecting lines or leakage currents
of semi-conductor switches and their pro-
tection circuits are lower than the release
voltage of the relay.
For DC relays, the release voltage is spe-
cified with a value of 5% of the nominal
voltage;
for AC relays it is 15% of the nominal
voltage (acc. to VDE 0435).
If a high residual voltage exists, it is
possible that the relay will not reset.
Addition of a parallel connection of an
RC element of:
R = 100-220
C = 220-470nF
could remedy this situation.
Definitions of several
important technical terms
Coil-side information
The relays can be used within the stated
temperature range with nominal voltage
plus tolerance at 100% contin uous duty
rating.
According to the type and application,
the relays are triggered with DC or AC
signal.
The DC versions (residual ripple 6%)
are, unless otherwise stated, equipped
with LED function indicators, a recovery
diode and a reverse voltage protection
diode.
Alternatively, the 286-904 relay
module is available.
This specially developed module
features a defined release point at
110VAC 10% at an operating
voltage (coil volt age) of 230 VAC.
For a nominal voltage of 12VDC,
the LED is connected in parallel to the coil.
For a nominal voltage 24VDC,
the LED isconnected in series with the coil.
WAGO Relay Modules
0
10
+
<
_
_
_
_
_
_
_
_
_
_
<
_
_
_
_
_
_
_
_
_
_
+
<
_
_
_
_
_
_
_
_
_
_
VDR
+
_
_
_
_
_
_
_
_
_
_
>
R
C
+
<
_
_
_
_
_
_
_
_
_
_
+
connec-
tion ensures a secure, maintenance-free
connection for conductors sized from
0.08 mm
2
to 2.5 mm
2
/AWG 28-12.
Temperature transducers
Temperature sensing in the process
industry is traditionally performed via
Thermocouple or RTD (Platinum Resi-
stance) elements. A popular RTD is the
Pt100 element. Having a nominal resi-
stance of 100 ohm at 0C, and a typical
operating temperature range of 200C
to + 650C, its non-linear characteri-
stics are compensated by the WAGO
signal conditioning module, as the Pt100
element typically meets the IEC 60571
specification.
The WAGO Pt100 signal conditioning
module is suitable for 2- or 3-wire RTD,
with 3-wire RTDs offering greater accura-
cy over longer distances. Thermocouples
consist of two different metals that are
connected at the measuring point and
utilize of the Dissimilar Metal (EMF)
effect, which can be measured at the
open ends of an element.
WAGO analog signal conditioning
modules are designed to work with com-
mon types of J (Iron/Constantan) and
K (Chromel/Alumel) thermocouples,
which comply with IEC standard 60584
Pt. 1, with cold junction compen sation.
WAGO temperature transducers are
available with industry standard output
signals of 0-10 V, 0-20 mA or 4-20 mA.
Additionally, they have an integral wire
break/short circuit detection. Visual
LED fault indication is standard, but the
WAGO modules also include an error
output signal that may be used to initiate
a safe shutdown before serious damage
occurs in the event of a wire break or
short circuit of the measuring sensor.
For this purpose, a transistor switches the
output as soon as the operating voltage
is correct and no error is present in the
measuring circuit on VB-2V. The transistor
blocks the output in the case of an error.
WAGO temperature transducers are
available as follows:
The wire break and short circuit
error output is available on the
Pt100 module.
The wire break function is available-
on the J and K Thermocouple modules.
In the event of wire break, the outputs
switch to the following values:
Output Value
0(4)-20mA 20.5mA
0-10V 14V
With Pt100 modules, and in case of
short circuit, the outputs switch
to 0V or 0mA, respectively.
The mechanical assemble of pluggable
modules for rail-mounted terminal blocks
on DIN 35 rails offers all the advantages
of CAGE CLAMP
connectivity.
Additionally, the separation of wiring and
function levels offer maximum flexibility
and ease of service.
When using insulated thermocouples, terminal 2
has to be connected to 0 V.
In the case of grounded (earthed) thermo couples,
the design is such that terminal 2 is alread connec-
ted to 0 V inside the thermo couple element.
Therefore, it is not necessary to jumper 2 0 V.
For commoning 2 0 V, 4-wire base terminals are
recommended.
0
14
WAGO Interface Modules
WAGO Interface Modules
Interface modules connect electronic to
electromechanical functions at the control
level.
They connect:
signal transmission,
control system field
signal distribution,
control system field.
They allow prefabricated plugs to inter-
face to discrete field wiring.
WAGO AUTOMATION offers a wide
range of interface modules for commonly
used connector types. The use of these
interface modules offers the following
advantages in the system wiring:
easy and time-saving planning and
calculations
rapid wiring, starting and fault
elimination by clearly arranged wiring
and clear pole marking, reduction of
wiring faults
safe and maintenance-free connection
of the signal lines with the
CAGE CLAMP
terminal strips
high packing density creates
space-saving modules
The interface modules are standard in
a universal mounting carrier for DIN 35
carrier rails with the following
connectors:
Subminiature-D connectors
acc. to DIN 41 652 or MIL-C-24308
Interface modules for male and female
connectors are available with 9, 15, 25,
37 or 50 contacts. Compared with the
standard solder connection, the mating
connector with IDC connection offers
additional advantages.
Connectors
acc. to IEC 60603/DIN 41 612,
types C, E and F
These connectors are frequently used for
compact input and output component
groups and are available for
32-, 48- and 64-pole pin and socket con-
nectors, as well as for mating
connectors with solder and IDC contacts.
Ribbon cable connectors
acc. to IEC 60603-1 / DIN 41 651
or MIL-C-83503
Interface modules with 10-, 14-, 16-,
20-, 26-, 34-, 40-, 50- and 64-pole con-
nectors are available for ribbon cable
connectors.
0
15
WAGO EPSITRON 787 Series
High-Performance and Efficient Advanced Power Supplies
PRO Power Supplies
Slimline, 1- and 3-phase, primary switch
mode power supplies feature a wide
input voltage range, stabilized, adjustable
24VDC output voltage and up to 93%
high efficiency. An integrated Power-
Boost (up to 200 % output power for 4
seconds) allows reliable starting of heavy
loads with high inrush currents, eliminating
expensive oversizing of the switch mode
power supply. The TopBoost function,
which provides a much higher output cur-
rent of up to 60A for 50ms, permits use
of standard circuit breakers for protection
on the secondary side. This enables safe
tripping within the time limits required by
the EN 60204 standard.
Select devices utilize the LineMonitor fea-
ture for current and voltage monitoring,
fault memory and parameterization opti-
ons via LCD display, on-unit function keys,
or free monitoring software and available
RS-232 interface from a PC and PLC. This
allows the power supply to replace addi-
tional devices, such as phase failure and
phase sequence monitoring devices or
operational hour meters.
Additionally, the single-phase power sup-
plies have a stand-by mode to switch off
the device output via remote input, while
minimizing power consumption. CAGE
CLAMP
pluggable terminations permit efficient
pre-wiring.
The CLASSIC Power Supplies are avai-
lable in four nominal output voltages:
12VDC, 24VDC or 48VDC, as well as
30.5VDC for AS-Interface networks.
ECO Power Supplies
Single-phase, primary switch mode
power supplies in sturdy metal housing
offer a wide input voltage range from 90
to 264VAC, without manual switching.
The stabilized, front-panel adjustable
24VDC output voltage is protected
against open and short circuits, and
constant current operation is provided in
the overload range. LEDs quickly provide
operational status at a glance. CAGE
CLAMP
0
18
0 20 40 60 s
kV
12
10
8
6
4
2
0
1 kV/ms
0 1 2 s
V
600
500
400
300
200
100
0
0 1 2 s
V
600
500
400
300
200
100
0
0 1 2 s
V
600
500
400
300
200
100
0
L
a
L
a
duration of
surge voltage
a)
or R gas-filled surge
arrester
varistor suppression
diode
applicance to
be protected
Function diagram of a multi-stage surge voltage protection module
Frequently, only one surge arrester is fitted for
cost reasons. However, due to the fact that
one surge arrester alone cannot optimally
ensure several protection functions, combinati-
ons are recommended. Care must be taken to
ensure that the single-stage protection devices
are decoupled sufficiently by inductors or
resistors.
In addition to single-stage surge arresters,
WAGO AUTOMATION also offers multi-
stage surge arresters, combining components
for different applications. These pluggable
modules are snapped into carrier terminal
blocks. These are DIN rail-mounted and offer
secure and maintenance-free
CAGE CLAMP
Transducers
0
24
Function Input Output Electrical Isolation Supply Voltage V
N
Item No. Page
Signal Conditioning
Modules for Standard Signals
0 10 V
0 10 V
2 ways, 4 kV
24 VDC
786-301 278
3 ways, 4 kV 786-321 278
0 20 mA
2 ways, 4 kV 786-302 278
3 ways, 4 kV 786-322 278
4 20 mA
2 ways, 4 kV 786-303 278
3 ways, 4 kV 786-323 278
0 20 mA
0 10 V
2 ways, 4 kV
24 VDC
786-304 279
3 ways, 4 kV 786-324 280
0 20 mA
2 ways, 4 kV 786-305 279
3 ways, 4 kV 786-325 280
4 20 mA
2 ways, 4 kV 786-306 279
3 ways, 4 kV 786-326 280
4 20 mA
0 10 V
2 ways, 4 kV
24 VDC
786-307 279
3 ways, 4 kV 786-337 280
0 20 mA
2 ways, 4 kV 786-308 279
3 ways, 4 kV 786-338 280
4 20 mA
2 ways, 4 kV 786-309 279
3 ways, 4 kV 786-339 280
Function Input Temperature Range Connection Output Electrical Isolation
Supply Voltage
V
N Item No. Page
Temperature
Transducers
Pt 100
0 C ... 100 C
2 wire
0 10 V
24 VDC
286-860 272
3 wire 286-870 272
2 wire
0 20 mA
286-861 272
3 wire 286-871 272
2 wire
4 20 mA
286-862 272
3 wire 286-872 272
-30 C ... +150 C
2 wire
0 10 V
24 VDC
286-860/150--030 274
3 wire 286-870/150--030 274
2 wire
0 20 mA
286-861/150--030 274
3 wire 286-871/150--030 274
2 wire
4 20 mA
286-862/150--030 274
3 wire 286-872/150--030 274
0 C ... 300 C
2 wire
0 10 V
24 VDC
286-860/000-300 275
3 wire 286-870/000-300 275
2 wire
0 20 mA
286-861/000-300 275
3 wire 286-871/000-300 275
2 wire
4 20 mA
286-862/000-300 275
3 wire 286-872/000-300 275
Pt 1000 0 C ... 100 C 2 wire
0 10 V
24 VDC
286-873 276
0 20 mA 286-874 276
4 20 mA 286-875 276
Thermocouple
Type J
0 C ... 750 C
0 10 V
24 VDC
286-863 273
0 20 mA 286-865 273
4 20 mA 286-867 273
Thermocouple
Type K
0 C ... 1000 C
0 10 V
24 VDC
286-864 273
0 20 mA 286-866 273
4 20 mA 286-868 273
786 Seriea
286 Series
Signal Conditioning Modules
Temperature Transducers
0
25
857 Series
JUMPFLEX
Interface Adapters 62 63
WAGO Ribbon Cables 64 67
Miniature Switching Relays, Solid State Relays, Sockets, Accessories, 857 Series 68 71
788 Series
Sockets with Miniature Switching Relay 72 83
Sockets with Solid State Relay 84 85
Miniature Switching Relays, Sockets 86 89
Accessories, 788 Series 90 91
287/288 Series
Mounting Carriers with Miniature Switching Relay 100 111
286 Series
Pluggable Modules Relays, Time Relays, Optocouplers,
S0 Optocouplers, S0 Supply Module, NAMUR Switching Amplifiers,
Current Flow Monitoring, Switches, Bridge Rectifiers,
Fuses, Diode Gates, AND Gate and LED Indicator,
Flip-Flop, Fault Indication 112 151
859 Series
Rail-Mounted Terminal Blocks with Miniature Switching Relay 32 38
Rail-Mounted Terminal Blocks with Optocoupler 39 47
Rail-Mounted Terminal Blocks with Miniature Switching Relays and Optocouplers
with an Extended Input Voltage and Operating Temperature Rangeh 48
Accessories, 859 Series 49
789 Series
Relay Modules in DIN-Rail Mounted Enclosure 152 161
Accessories, Series 789 162
Current Sensor with Bus Connection in DIN-Rail Mountable Enclosure 164 169
3-Channel Rogowski Signal Conditioner 170
4-Channel EnOcean Radio Receiver in DIN-Rail-Mountable Enclosure 172
Manual Control Modules 173
1
31
1
32
Rail-Mounted Terminal Blocks with Miniature Switching Relay
Relay with 1 changeover contact (1u)
for normal switching power
Nominal input voltage V
N
5 V, 12 V, 24 V, 48 V, 60 V, 110 V, 220 V DC
Relay with 1 changeover contact (1u)
for normal switching power
Nominal input voltage V
N
12 V, 24 V, 48 V, 115 V, 230 V AC/DC
Note: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay coils
and contacts.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with miniature
switching relay, for DIN 35 rail
5 V DC 31 mA 859-302 1 12 V AC/DC 15 mA 859-353 1
12 V DC 17 mA 859-303 1 24 V AC/DC 8 mA 859-354 1
24 V DC 10 mA 859-304 1 48 V AC/DC 5.3 mA 859-355 1
48 V DC 6.5 mA 859-305 1 115 V AC/DC 3.5 mA 859-357 1
60 V DC 5.2 mA 859-306 1 230 V AC/DC 3.5 mA 859-358 1
120 V DC 3.5 mA 859-307 1
220 V DC 3.2 mA 859-308 1
Technical Data Accessories see page 49 Accessories see page 49
Contact material AgSnO
2
AgSnO
2
Input voltage range V
N
-15 % ... +10 % V
N
-15 % ... +10 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current (terminal blocks in a row) 5 A 5 A
Max. Switching power (resistive) 1250 VA AC ; DC see load limit curve 1250 VA AC ; DC see load limit curve
Recommended minimum load t 100 mA / 12 V AC/DC t 100 mA / 12 V AC/DC
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
6 min
-1
/ 20 s
-1
Operating power < 320 mW < 300 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength contact-coil (1.2/50 s) 6 kV 6 kV
Surge capacity open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 3 x 10
5
switching operations 3 x 10
4
switching operations
Ambient operating temperature (V
N
) -25 C ... +50 C -25 C ... +50 C
Ambient operating temperature (1.2 x V
N
) -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
A1
+
14
12
11
A2
14
12
11
A1
A2
1
33
1
Relay with 1 changeover contact (1u)
Contacts 5 m Au hard gold plated
for normal switching power
Nominal input voltage V
N
24 V DC
Relay with 1 changeover contact (1u)
Contacts 5 m Au hard gold plated
with an extended
Input voltage range: V
N
-30 % ... +25 %
Operating temperature range: -25 C ... +70 C
for normal switching power
Nominal input voltage V
N
115 V DC
* In order to prevent the gold layer from being damaged
these values should not be exceeded. Higher switching
power leads to evaporation of the gold layer. The resulting
deposits in the enclosure may cause sparkovers between
the coil and the contact.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with miniature
switching relay, for DIN 35 rail
24 V DC 10 mA 859-314 1 115 V DC 3.1 mA 859-317 1
Technical Data Accessories see page 49 Accessories see page 49
Contact material AgSnO
2
+ 5 m Au AgSnO
2
+ 5 m Au
Input voltage range V
N
-15 % ... +20 % V
N
-30 % ... +25 %
Max. switching voltage 36 V DC * 36 V DC *
Max. continuous current (terminal blocks in a row) 50 mA * 50 mA *
Recommended minimum load 10 A / 100 mV 10 A / 100 mV
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
6 min
-1
/ 20 s
-1
Operating power < 320 mW < 320 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength contact-coil (1.2/50 s) 6 kV 6 kV
Surge capacity open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 5 x 10
6
switching operations 5 x 10
6
switching operations
Ambient operating temperature (V
N
) -25 C ... +50 C -25 C ... +70 C
Ambient operating temperature (1.2 x V
N
) -25 C ... +40 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A1
+
14
12
11
A2
A1
+
14
12
11
A2
1
34
Rail-Mounted Terminal Blocks with Miniature Switching Relay
Relay with 1 changeover contact (1u)
Contacts 5 m Au hard gold plated
for normal switching power
Nominal input voltage V
N
230 V AC
Relay with 1 changeover contact (1u)
Contacts 5 m Au hard gold plated
for normal switching power
Nominal input voltage V
N
115 V AC
* In order to prevent the gold layer from being damaged
these values should not be exceeded. Higher switching
power leads to evaporation of the gold layer. The resulting
deposits in the enclosure may cause sparkovers between
the coil and the contact.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with miniature
switching relay, for DIN 35 rail
230 V AC 3.5 mA 859-359 1 115 V AC 3.1 mA 859-360 1
Technical Data Accessories see page 49 Accessories see page 49
Contact material AgSnO
2
+ 5 m Au AgSnO
2
+ 5 m Au
Input voltage range V
N
-15 % ... +10 % V
N
-15 % ... +20 %
Max. switching voltage 36 V DC * 36 V DC *
Max. continuous current (terminal blocks in a row) 50 mA * 50 mA *
Recommended minimum load 10 A / 100 mV 10 A / 100 mV
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
6 min
-1
/ 20 s
-1
Operating power < 820 mW < 370 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength contact-coil (1.2/50 s) 6 kV 6 kV
Surge capacity open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 5 x 10
6
switching operations 5 x 10
6
switching operations
Ambient operating temperature (V
N
) -25 C ... +50 C -25 C ... +50 C
Ambient operating temperature (1.2 x V
N
) -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
14
12
11
A1
~
A2
~
14
12
11
A1
~
A2
~
1
35
1
Relay with 1 changeover contact (1u)
Contacts 5 m Au hard gold plated
for low switching power
Nominal input voltage V
N
220 V DC
Relay with 1 changeover contact (1u)
for normal switching power
Nominal input voltage V
N
115 V AC
* In order to prevent the gold layer from being
damaged these values should not be exceeded.
Higher switching power leads to evaporation of the
gold layer. The resulting deposits in the endosure may
cause sparkover between the coil and the contact.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with miniature
switching relay, for DIN 35 rail
220 V DC 3.2 mA 859-318 1 115 V AC 4.2 mA 859-367 1
Technical Data Accessories see page 49 Accessories see page 49
Contact material AgSnO
2
+ 5 m Au AgSnO
2
Input voltage range V
N
-15 % ... +20 % V
N
10 %
Turn-on threshold relay/LED 95 V AC/ 80 V AC
Turn-off threshold relay/LED 60 V AC/60 V AC
Max. switching voltage 36 V DC * 250 V AC
Max. continuous current (terminal blocks in a row) 50 mA * 5 A
Max. Switching power (resistive) 1250 VA AC ; DC see load limit curve
Recommended minimum load 50 mW t 100 mA / 12 V AC/DC
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
6 min
-1
/ 20 s
-1
Operating power < 750 mW < 820 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength contact-coil (1.2/50 s) 6 kV 6 kV
Surge capacity open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 5 x 10
6
switching operations 3 x 10
4
switching operation
Ambient operating temperature (V
N
) -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0435 (corresp. parts); DIN EN 61810;
DIN VDE 0140, DIN EN 61140 E175199, UL 508; g
DIN VDE 0160, DIN EN 50178; VDE 0435
(corresp. parts); DIN EN 61810; VDE 0140,
DIN EN 61140; g
1
36
Rail-Mounted Terminal Blocks with Miniature Switching Relay
Relay with 1 changeover contact (1u)
defined turn-on/turn-off threshold
for normal switching power
Nominal input voltage V
N
230 V AC
Relay with 1 changeover contact (1u)
with an extended
Input voltage range: V
N
-30 % ... +25 %
Operating temperature range: -25 C ... +70 C
for normal switching power
Nominal input voltage V
N
24 V DC
Note: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay coils
and contacts.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with miniature
switching relay, for DIN 35 rail
230 V AC 4.2 mA 859-368 1 24 V DC 12 mA 859-390 1
Technical Data Accessories see page 49 Accessories see page 49
Contact material AgSnO
2
AgSnO
2
Input voltage range V
N
10 % V
N
-30 % ... +25 %
Turn-on threshold relay/LED 190 V AC / 165 V AC
Turn-off threshold relay/LED 140 V AC / 150 V AC
Max. switching voltage 250 V AC 250 V AC
Max. continuous current (terminal blocks in a row) 5 A 3 A
Max. Switching power (resistive) 1250 VA AC ; DC see load limit curve 750 VA AC ; DC see load limit curve
Recommended minimum load t 100 mA / 12 V AC/DC t 100 mA / 15 V AC/DC
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
6 min
-1
/ 20 s
-1
Operating power < 820 mW < 320 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength contact-coil (1.2/50 s) 6 kV 6 kV
Surge capacity open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 3 x 10
4
switching operation 3 x 10
5
switching operation
Ambient operating temperature (V
N
) -25 C ... +50 C -25 C ... +70 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
14
12
11
A1
~
A2
~
14
12
11
A1
+
A2
1
37
1
Relay with 1 changeover contact (1u)
with an extended
Input voltage range: V
N
30 %
Operating temperature range: -25 C ... +70 C
for normal switching power
Nominal input voltage V
N
110 V DC
Relay with 1 changeover contact (1u)
with an extended
Input voltage range: V
N
40 %
Operating temperature range: -25 C ... +70 C
for normal switching power
Nominal input voltage V
N
24 V DC
NOTE: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay
coils and contacts.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with miniature
switching relay, for DIN 35 rail
110 V DC 2.7 mA 859-391 1 24 V DC 14.4 mA 859-398 1
Technical Data Accessories see page 49 Accessories see page 49
Contact material AgSnO
2
AgSnO
2
Input voltage range V
N
30 % V
N
40 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current (terminal blocks in a row) 3 A 3 A
Max. Switching power (resistive) 750 VA AC ; DC see load limit curve 750 VA AC ; DC see load limit curve
Recommended minimum load t 100 mA / 15 V AC/DC t 100 mA / 12 V AC/DC
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
6 min
-1
/ 20 s
-1
Operating power < 370 mW < 400 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength contact-coil (1.2/50 s) 6 kV 6 kV
Surge capacity open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 1 x 10
7
switching operations
Mechanical life at max. load (resistance) 3 x 10
4
switching operation 3 x 10
4
switching operation
Ambient operating temperature (V
N
) -25 C ... +70 C -25 C ... +70 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nC II T4 / DEMKO 02 ATEX 132280U; g
DIN VDE 0160 and IEC 60255; VDE 0435
(corresp. parts); DIN VDE 0140, DIN EN 61140;
DIN VDE 0115 Part 200; DIN EN 50155; g
14
12
11
A1
+
A2
1
38
Rail-Mounted Terminal Blocks with Miniature Switching Relay
Relay with 1 changeover contact (1u)
Contacts 5 m Au hard gold plated
with an extended
Input voltage range: V
N
-30 % ... +25 %
Operating temperature range: -25 C ... +70 C
for normal switching power
Nominal input voltage V
N
24 V DC
* In order to prevent the gold layer from being damaged
these values should not be exceeded. Higher switching
power leads to evaporation of the gold layer. The resulting
deposits in the enclosure may cause sparkovers between
the coil and the contact.
Description V
N
I
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with miniature
switching relay, for DIN 35 rail
24 V DC 10 mA 859-392 1
Technical Data Accessories see page 49
Contact material AgSnO
2
+ 5 m Au
Input voltage range V
N
-30 % ... +25 %
Max. switching voltage 36 V DC *
Max. continuous current (terminal blocks in a row) 50 mA *
Recommended minimum load 10 A / 100 mV
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
Operating power < 320 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty
Dielectric strength contact-coil 4 kV
Dielectric strength contact-coil (1.2/50 s) 6 kV
Surge capacity open contact 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 2 x 10
7
switching operations
Ambient operating temperature (V
N
) -25 C ... +70 C
Storage temperature -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
VDE 0115 Part 200 / EN 50155; UL 508; EEx nA II T4 /
DEMKO 02 ATEX 132280U
VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
VDE 0115 Part 200 / EN 50155; UL 508; EEx nA II T4 /
DEMKO 02 ATEX 132280U
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A1
+
A2
1
+
2
RL
A1
+
A2
1
+
2
RL
1
40
Rail-Mounted Terminal Blocks with Optocoupler
Optocoupler
Input: 24 V DC
Output: 24 V DC/100 mA
Optocoupler
Input: 5 V DC
Output: 24 V DC/100 mA
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
24 V DC 859-796 1 5 V DC 859-795 1
Technical Data Accessories see page 49 Accessories see page 49
Nominal input voltage (V
N
) 24 V DC 5 V DC
Input voltage range low level 0 V ... 5 V DC 0 V ... 0.8 V DC
Input voltage range high level 18 V ... 30 V DC 2 V ... 6.25 V DC
Input current range 3.8 mA ... 12.5 mA DC 3.8 mA ... 23 mA DC
Current at nominal voltage 9.2 mA DC 17.5 mA DC
Output nominal voltage 24 V DC 24 V DC
Output voltage range 3 V ... 30 V DC 3 V ... 30 V DC
Max. continuous current (20C) 100 mA 100 mA
Max. continuous current (70C) 50 mA 50 mA
Reverse voltage transistor 65 V 65 V
Switch on /switch off time 10 s / 50 s 10 s / 50 s
Max. operating frequency 10 kHz 10 kHz
Leakage current at nominal voltage 25 A 25 A
Voltage drop at output d 1 V d 1 V
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal operating mode continuous duty continuous duty
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Max. operating temperature with reduced current +70 C +70 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nA II T4 / DEMKO 02 ATEX 132280U
VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nA II T4 / DEMKO 02 ATEX 132280U
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A1
+
A2
1
+
2
RL
A1
+
A2
1
+
2
RL
1
1
41
Optocoupler
Input: 24 V DC
Output: 24 V DC/100 mA
Optocoupler
Input: 24 V DC
Output: 24 V DC/3 A
Negative switching
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
24 V DC 859-794 1 24 V DC 859-720 1
Technical Data Accessories see page 49 Accessories see page 49
Nominal input voltage (V
N
) 24 V DC 24 V DC
Input voltage range 16 V ... 30 V DC
Input voltage range low level 0 V ... 5 V DC
Input voltage range high level 16 V ... 30 V DC
Input current range 2 mA ... 5.5 mA DC 2.5 mA ... 5.5 mA DC
Current at nominal voltage 4.2 mA DC 4 mA DC
Output nominal voltage 24 V DC 24 V DC
Output voltage range 9 V ... 60 V DC 10 V ... 30 V DC
Max. continuous current 3 A
Max. continuous current (20C) 100 mA
Max. continuous current (70C) 50 mA
Peak output current 20 A
Reverse voltage transistor 100 V 55 V
Switch on /switch off time 20 s / 120 s 25 s / 75 s
Max. operating frequency 1.5 kHz
Switching frequency f < 500 Hz
IL < 2 A / IL < 1 A / IL < 500 mA f < 1 kHz / f < 2 kHz / f < 3 kHz
Leakage current at nominal voltage 25 A < 25 A
Collector / emitter voltage drop Vce sat d 0.5 V
Voltage drop at output d 2 V
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal operating mode continuous duty continuous duty
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nA II T4 / DEMKO 02 ATEX 132280U
VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nA II T4 / DEMKO 02 ATEX 132280U
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A1
+
A2
1
+
2
RL
A1
+
A2
RL
0V
A
24V
1
42
Rail-Mounted Terminal Blocks with Optocoupler
Optocoupler
Input: 24 V DC
Output: 24 V DC/3 A
Optocoupler
Input: 24 V DC
Output: 3V ... 30 V DC/3A
3 A power optocoupler
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
24 V DC 859-730 1 24 V DC 859-740 1
Technical Data Accessories see page 49 Accessories see page 49
Nominal input voltage (V
N
) 24 V DC 24 V DC
Input voltage range low level 0 V ... 5 V DC 0 V ... 9 V DC
Input voltage range high level 15 V ... 27 V DC 19 V ... 27 V DC
Current at nominal voltage 14 mA DC 7 mA DC
Input wiring Status LED (red) status indication LED (yellow), reverse voltage protection
Output circuit 2-wire, isolated 2-wire, isolated, overvoltage protection
Output nominal voltage 24 V DC 24 V DC
Output voltage range 3 V ... 30 V DC 3 V ... 30 V DC
Max. continuous current 3 A 3 A
Peak output current 25 A 25 A
Reverse voltage transistor 55 V
Voltage drop < 0.4 V < 0.2 V
Switch on /switch off time 25 s / 450 s 25 s / 450 s
Switching frequency f < 350 Hz f < 350 Hz
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal operating mode continuous duty continuous duty
Ambient operating temperature -25 C ... +55 C -25 C ... +55 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-5;
UL 508; EEx nA II T4 / DEMKO 02 ATEX 132280U
IEC 60664 / IEC 60664A / DIN VDE 0110;
degree of pollution 2,
overvoltage category III
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A1
+
A2
RL
+A
-2
-2
13+
14
A2
A1
+
1
1
43
Optocoupler
Input: 230 V AC
Output: 24 V DC/0.5 A
Positive switching increased input frequency
up to 100 Hz
Input voltage up to 270 V AC
Optocoupler
Input: 230 V DC
Output: 24 V DC/0.5 A
Negative switching
859-772
Increased input frequency up to 100 Hz
Input voltage up to 270 V AC
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
230 V AC 859-772 1 230 V AC 859-712 1
Technical Data Accessories see page 49 Accessories see page 49
Nominal input voltage (V
N
) 230 V AC/ 50 Hz ... 60 Hz 230 V AC
Input voltage range low level 0 V ... 90 V AC 0 V ... 90 V AC
Input voltage range high level 175 V ... 270 V AC 175 V ... 250 V AC
Input current range 0.04 mA ... 0.7 mA 0.4 mA ... 0.7 mA
Current at nominal voltage 0.6 mA 0.6 mA
Input wiring Varistor 300 V Varistor 300 V
Output circuit Protection diode, operation indicator Protection diode, operation indicator LED (red)
Output nominal voltage 24 V DC 24 V DC
Output voltage range 20 V ... 30 V DC 20 V ... 30 V DC
Max. continuous current 500 mA 500 mA
Reverse voltage transistor 80 V 80 V
Switch on /switch off time < 30 ms / < 30 ms < 30 ms / < 30 ms
Leakage current at nominal voltage 10 A 10 A
Collector / emitter voltage drop Vce sat < 1.2 V < 1.2 V
Max. output (reverse current) 12 mA 11 mA
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal operating mode continuous duty continuous duty
Ambient operating temperature -25 C ... +55 C -25 C ... +55 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
RL
1
+
3
2
24 V
A
0 V
A2
~
A1
~
A2
~
A1
~
0 V
+24 V
A
RL
1
44
Rail-Mounted Terminal Blocks with Optocoupler
Optocoupler
Input: 5 V DC
Output: 24 V DC/0.5A/25 kHz
Negative switching
Optocoupler
Input: 24 V DC
Output: 24 V DC/0.5A/25 kHz
Negative switching
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
5 V DC 859-702 1 24 V DC 859-708 1
Technical Data Accessories see page 49 Accessories see page 49
Nominal input voltage (V
N
) 5 V DC 24 V DC
Input voltage range low level 0 V ... 1 V DC 0 V ... 5 V DC
Input voltage range high level 4 V ... 6.25 V DC 19 V ... 30 V DC
Input current range 7 mA ... 13 mA 5.7 mA ... 10.2 mA
Current at nominal voltage 9.6 mA DC 7.7 mA DC
Input wiring Reverse voltage protection Reverse voltage protection
Output circuit Protection diode, operation indicator LED (red) Protection diode, operation indicator LED (red)
Output nominal voltage 24 V DC 24 V DC
Output voltage range 20 V ... 30 V DC 20 V ... 30 V DC
Max. continuous current 500 mA 500 mA
Reverse voltage transistor 80 V 80 V
Switch on /switch off time < 7 s / < 15 s < 10 s / < 10 s
Max. operating frequency 10 kHz 10 kHz
Leakage current at nominal voltage < 10 A < 10 A
Collector / emitter voltage drop Vce sat < 1.2 V < 1.2 V
Max. output (reverse current) 11 mA 11 mA
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal operating mode continuous duty continuous duty
Ambient operating temperature -25 C ... +55 C -25 C ... +55 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A2
A1
+
0 V
+24 V
A
RL
A2
A1
+
0 V
+24 V
A
RL
1
1
45
Optocoupler
Input: 24 V DC
Output: 5 V DC/0.5A/25 kHz
Negative switching
Optocoupler
Input: 5 V DC
Output: 24 V DC/0.5 A/10 kHz
Positive switching
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
24 V DC 859-706 1 5 V DC 859-752 1
Technical Data Accessories see page 49 Accessories see page 49
Nominal input voltage (V
N
) 24 V DC 5 V DC
Input voltage range low level 0 V ... 5 V DC 0 V ... 1 V DC
Input voltage range high level 18 V ... 30 V DC 4 V ... 6 V DC
Input current range 8 mA ... 14 mA 7 mA ... 13 mA
Current at nominal voltage 11 mA DC 10 mA
Input wiring Reverse voltage protection Reverse voltage protection
Output circuit Protection diode, operation indicator LED (red) Protection diode, operation indicator LED (red)
Output nominal voltage 5 V DC 24 V DC
Output voltage range 4 V ... 6.25 V DC 20 V ... 30 V DC
Max. continuous current 500 mA 500 mA
Reverse voltage transistor 80 V 80 V
Switch on /switch off time < 7 s / < 15 s < 15 s / < 30 s
Max. operating frequency 10 kHz 10 kHz
Leakage current at nominal voltage < 10 A < 10 A
Collector / emitter voltage drop Vce sat < 1.2 V < 1.2 V
Max. output (reverse current) 7 mA 12.5 mA
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal operating mode continuous duty continuous duty
Ambient operating temperature -25 C ... +55 C -25 C ... +40 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A2
A1
+
0 V
+5 V
A
RL
A2
A1
+
0 V
+24 V
A
RL
1
46
Rail-Mounted Terminal Blocks with Optocoupler
Optocoupler
Input: 24 V DC
Output: 24 V DC/0.5 A/10 kHz
Positive switching
Optocoupler
Input: 24 V DC
Output: 5 V DC/0.5 A/10 kHz
Positive switching
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
24 V DC 859-758 1 24 V DC 859-756 1
Technical Data Accessories see page 49 Accessories see page 49
Nominal input voltage (V
N
) 24 V DC 24 V DC
Input voltage range low level 0 V ... 5 V DC 0 V ... 5 V DC
Input voltage range high level 18 V ... 30 V DC 18 V ... 30 V DC
Input current range 5.5 mA ... 10.6 mA 8 mA ... 14.5 mA
Current at nominal voltage 8 mA 11 mA
Input wiring Reverse voltage protection Reverse voltage protection
Output circuit Protection diode, operation indicator LED (red) Protection diode, operation indicator LED (red)
Output nominal voltage 24 V DC 5 V DC
Output voltage range 20 V ... 30 V DC 4 V ... 6.25 V DC
Max. continuous current 500 mA 500 mA
Reverse voltage transistor 80 V 80 V
Switch on /switch off time < 15 s / < 30 s < 15 s / < 30 s
Max. operating frequency 10 kHz 10 kHz
Leakage current at nominal voltage < 10 A < 10 A
Collector / emitter voltage drop Vce sat < 1.2 V < 1.2 V
Max. output (reverse current) 11 mA 4.5 mA
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal operating mode continuous duty continuous duty
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
VDE 0110 / EN 60664; UL 508;
EEx nA II T4 / DEMKO 02 ATEX 132280U
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
A2
A1
+
0 V
+24 V
A
RL
A2
A1
+
0 V
+5 V
A
RL
1
1
47
Optocoupler
Input: 5 V DC
Output: 230 V AC/0.5 A
Description V
N
Item No.
Pack.
Unit
Rail-mounted terminal blocks with optocoupler, for
DIN 35 rail
5 V DC 859-902 1
Technical Data Accessories see page 49
Nominal input voltage (V
N
) 5 V DC
Input voltage range low level 0 V ... 1 V DC
Input voltage range high level 4 V ... 6.25 V DC
Input current range DC 5.6 mA ... 10.3 mA
Current at nominal voltage 7.7 mA DC
Input wiring Reverse voltage protection
Output circuit varistor /RC module
Output nominal voltage 230 V AC
Output voltage range 24 V ... 260 V AC (50 Hz ... 60 Hz)
Max. continuous current (20C) 500 mA
Surge current (t=20 ms) 30 A
Min. load current 50 mA
Peak reverse voltage Triac 600 V
Switch on /switch off time 10 ms / 10 ms (1 half-wave)
Leakage current at nominal voltage < 1 mA
Voltage drop at output < 1 V
Test voltage input / output 2.5 kV eff.
Nominal operating mode continuous duty
Ambient operating temperature -25 C ... +55 C
Storage temperature -40 C ... +70 C
Dimensions (mm) W x H x L 6 x 56 x 91
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r
(857-358: r pending)
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
857-304
<_________ 94 mm/3.68 in _________>
____________
857-354
<_________ 94 mm/3.68 in _________>
____________
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
A2
A1
1
1
51
8
Relay with 1 changeover contact (1u)
(gold contacts)
for normal switching power
Nominal input voltage
V
N
24 V, 110 V, 220 V DC
Relay with 1 changeover contact (1u)
(gold contacts)
for normal switching power
Nominal input voltage
V
N
24 V, 115 V, 230 V AC/DC
* In order to prevent the gold layer from being damaged
these values should not be exceeded. Higher
switching power leads to evaporation of the gold layer.
The resulting deposits in the enclosure may
cause sparkovers between the coil and the contact.
The values in brackets are valid
if the gold layer is damaged.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
JUMPFLEX
S CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r
(857-368: r pending)
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
857-314
<_________ 94 mm/3.68 in _________>
____________
857-364
<_________ 94 mm/3.68 in _________>
____________
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
A2
A1
S
1
52
JUMPFLEX
Relay
With 2 relays, with 1 make contact (1 a)
for normal switching power
Nominal input voltage
V
N
24 V AC/DC
Note: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay coils
and contacts.
Description V
N
I
N
Item No.
Pack.
Unit
JUMPFLEX
Relais,
for DIN 35 rail
AC/DC 24 V 10 mA 857-1330 1
Technical Data Accessories see pages 68 ... 71
Contact material AgSnO
2
Input voltage range V
N
-15 % ... +20 %
Max. switching voltage 250 V AC
Max. continuous current (terminal blocks in a row) 4 A
Max. Switching power (resistive) AC 1000 VA; DC see load limit curve
Recommended minimum load t 100 mA / 12 V AC/DC
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
Operating power < 300 mW / < 700 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty
Dielectric strength contact-coil 2.5 kV
Surge capacity open contact 1 kV
eff
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 5 x 10
4
switching operations
Ambient operating temperature (V
N
) -25 C ... +60 C
Storage temperature -40 C ... +85 C
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Approvals VDE 0110 / EN 60664; VDE 0435 / EN 61810-1
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
A3
A4
23
24
A1
A2
13
14
1
1
53
1
54
JUMPFLEX
S CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Standards/Specifications EN 61000-6-2 with 859-891 Overvoltage Protection
Module for SSR*, EN 61000-6-4 (* pending)
EN 61000-6-2 with 859-891 Overvoltage Protection
Module for SSR*, EN 61000-6-4, EN 60664-1
(* pending)
Approvals 1*, g*, UL 508
* pending
1, g*, UL 508
* pending
<_________ 94 mm/3.68 in _________>
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
____________
13
N.C.
14
+
R
L
13
14
N.C.
A2
A1
+
R
L
1
1
55
Solid state relay
Input: 230 V AC/DC
Output: 0 V ... 48 V DC / 0.1 A
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Standards/Specifications EN 61000-6-2 with 859-891 Overvoltage Protection
Module for SSR*, EN 61000-6-4, EN 60664-1
(* pending)
Approvals 1, g*, UL 508
* pending
<_________ 94 mm/3.68 in _________>
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
____________
13
14
N.C.
A2
A1
+
R
L
S
1
56
JUMPFLEX
S CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Standards/Specifications EN 60664-1 EN 60664-1
Approvals 1, UL 508 1, UL 508
<_________ 94 mm/3.68 in _________>
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
____________
13
14
N.C.
+
R
L
A2
A1
13
14
N.C.
+
R
L
1
1
57
Solid state relay
Input: 230 V AC/DC
Output: 24 V ... 240 V AC / 1 A
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Standards/Specifications EN 60664-1
Approvals 1, UL 508
<_________ 94 mm/3.68 in _________>
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
____________
A2
A1
13
14
N.C.
+
R
L
S
1
58
JUMPFLEX
S CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Standards/Specifications EN 61000-6-2*, EN 61000-6-4;
*The operator has to take appropriate measures so as to
meet the requirements of immunity to interference for
electrical and electronic devices (acc. to EN 61000-6-2
and GL) on the output side, such as using the 859-890
Overvoltage Protection Module for SSR.
EN 61000-6-2*, EN 61000-6-4, EN 60664-1;
*The operator has to take appropriate measures so as to
meet the requirements of immunity to interference for
electrical and electronic devices (acc. to EN 61000-6-2
and GL) on the output side, such as using the 859-890
Overvoltage Protection Module for SSR.
Approvals 1, g, UL 508 1, g, UL 508
<_________ 94 mm/3.68 in _________>
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
____________
13
14
N.C.
+
R
L
A2
A1
13
14
+
R
L
N.C.
1
1
59
Solid state relay
Input: 230 V AC/DC
Output: 0 V ... 24 V DC / 2 A
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Standards/Specifications EN 61000-6-2*, EN 61000-6-4, EN 60664-1;
*The operator has to take appropriate measures so as to
meet the requirements of immunity to interference for
electrical and electronic devices (acc. to EN 61000-6-2
and GL) on the output side, such as using the 859-890
Overvoltage Protection Module for SSR.
Approvals 1, g, UL 508
<_________ 94 mm/3.68 in _________>
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
____________
A2
A1
13
14
N.C.
+
R
L
S
1
60
JUMPFLEX
Optocouplers
Optocoupler
Input: 2 x 24 VDC
Output: 2 x 9 60 VDC / 0.1 A
Optocoupler
Input: 2 x 24 VDC
Output: 2 x 3 30 VDC / 3 A
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
JUMPFLEX
Optocoupler,
for DIN 35 rail
857-1494 1 857-1430 1
Technical Data Accessories see pages 69 ... 71 Accessories see pages 69 ... 71
Control circuit:
Nominal input voltage (V
N
) 2 x 24 V DC 2 x 24 V DC
Input voltage range V
N
-30 % +25 % V
N
-30 % +25 %
Input voltage range (low level) 0 V ... 5 V 0 V ... 5 V
Input voltage range (high level) 16.8 V ... 30 V 16.8 V ... 30 V
Input current range 3 mA ... 7.8 mA 4.25 mA ... 11 mA
Nominal input current (I
N
) 5.6 mA 7.75 mA
Load circuit:
Switching voltage 2 x DC 9 V ... 60 V 2 x DC 3 V ... 30 V
Max. switching current 2 x 0.1 A DC 2 x 3 A DC
Peak reverse voltage 100 V 55 V
Forward voltage at max. switching current < 2 V < 0.2 V
Leakage current at nominal voltage 25 A 250 A
Switch on/switch off time 20 s / 120 s 25 s / 250 s
Max. switching frequency 1.5 kHz 300 Hz
Dielectric strength control/switching circuit 2.5 kV 2.5 kV
Dielectric strength channel/channel 4 kV 4 kV
Ambient operating temperature -25 C ... +70 C -25 C ... +70 C
Storage temperature -40 C ... +85 C -40 C ... +85 C
Dimensions (mm) W x H x L 6 x 96 x 94 6 x 96 x 94
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
A1
A2
13
14
RL
A3
A4
23
24
RL
A1
A2
13
14
RL
A3
A4
23
24
RL
1
1
61
Optocoupler
Input: 2 x 24 VDC
Output: 2 changeover contacts,
2 x 24 VDC / 0.5 A
Description Item No.
Pack.
Unit
JUMPFLEX
Optocoupler,
for DIN 35 rail
857-1432 1
Technical Data Accessories see pages 69 ... 71
Control circuit:
Nominal input voltage (V
N
) 24 V DC
Input voltage range V
N
-30 % +25 %
Input voltage range (low level) 0 V ... 5 V
Input voltage range (high level) 16.8 V ... 30 V
Input current range 5.3 mA ... 6.3 mA
Nominal input current (I
N
) 5.9 mA
Load circuit:
Switching voltage 2 x DC 3 V ... 30 V
Max. switching current 2 x 500 mA
Min. switching current 2 x 0.5 mA
Forward voltage at max. switching current < 1.5 V
Leakage current at nominal voltage 20 A
Switch on/switch off time 25 s / 250 s
Max. switching frequency 1.5 kHz
Dielectric strength control/switching circuit 3.75 kV
Ambient operating temperature -25 C ... +70 C
Storage temperature -40 C ... +85 C
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
A1
12
11
14
RL
A2
1
22
21
24
RL
1
S
1
62
JUMPFLEX
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
1
2
3 +
4
5
6
7
8
9
10
11
12
13
14
Interface
FLK 14
1
2
3 +
4
5
6
7
8
9
10
11
12
13
14
Interface
FLK 14
1
1
63
8-channel adapter
with SUB-D male connector
Input
Description Item No.
Pack.
unit
JUMPFLEX
Interface
Adapter (Item No. 857-981 and 857-982)
The cables provide fast and easy connection of WAGO I/O modules featuring ribbon
cable connectors. The following WAGO I/O modules and adapters are compatible:
750-1500 (16 DO) -- > 857-981 (DO)
750-1502 (8 DO / 8 DI) --> 857-981 (DO) and 857-982 (DI)
The ribbon cables are available in 1-, 2- and 3-meter lengths -- each has one 20-pole or
two 14-pole female connectors on the ends.
Suitable for system wiring when combined with the JUMPFLEX
Interface
Adapter (Item No. 857-981 and 857-982)
Description Item No.
Pack.
Unit
Description Item No.
Pack.
Unit
WAGO ribbon cable 14/14, 1m long 706-753/300-100 1 WAGO ribbon cable 20/2x14, 1m long 706-7753/304-100 1
WAGO ribbon cable 14/14, 2m long 706-753/300-200 1 WAGO ribbon cable 20/2x14, 2m long 706-7753/304-200 1
WAGO ribbon cable 14/14, 3m long 706-753/300-300 1 WAGO ribbon cable 20/2x14, 3m long 706-7753/304-300 1
Technical Data Technical Data
Connections 2 x 14-pole female connector
acc. to DIN 41651
Connections 1 x 20-pole female connector /
2 x 14-pole female connector to
DIN 41651 Wire cross-section 0.14 mm
2
LiYY
Color coding acc. to DIN VDE 47100 Wire cross-section 0.14 mm
2
LiYY
Current per channel max. 1 A Color coding acc. to DIN VDE 47100
Operating temperature -25 C ... +70 C Current per channel max. 1 A
Degree of protection IP20 Operating temperature -25 C ... +70 C
Length 1 m (706-753/300-100)
2 m (706-753/300-200)
3 m (706-753/300-300)
Degree of protection IP20
Length 1 m ( 706-7753/304-100)
2 m (706-7753/304-200)
3 m (706-7753/304-300)
14-pole female connector 14-pole female connector
20-pole female connector
14-pole female connector 14-pole female connector
1
1
65
WAGO Ribbon Cables
The cables provide fast and easy connection of WAGO I/O modules featuring ribbon
cable connectors. The following WAGO I/O modules and D-sub adapters are
compatible:
750-1500 (16 DO) --> 857-986 (DO)
The ribbon cables are available in 1-, 2- and 3-meter lengths -- each has one 20-pole or
two 15-pole female connectors on the ends.
Suitable for system wiring when combined with the JUMPFLEX
Interface
Adapter (Item No. 857-986)
Description Item No.
Pack.
Unit
WAGO ribbon cable 20/2x15, 1m long 706-7753/306-100 1
WAGO ribbon cable 20/2x15, 2m long 706-7753/306-200 1
WAGO ribbon cable 20/2x15, 3m long 706-7753/306-300 1
Technical Data
Connections 1 x 20-pole female connector to
DIN 41651 / 2 x 15-pole D-sub female
connector to DIN 41652
Wire cross-section 0.14 mm
2
LiYY
Color coding acc. to DIN VDE 47100
Current per channel max. 1 A
Operating temperature -25 C ... +70 C
Degree of protection IP20
Length 1 m (706-7753/306-100)
2 m (706-7753/306-200)
3 m (706-7753/306-300)
20-pole female connector
15-pole D-sub female
connector
15-pole D-sub female
connector
1
66
WAGO Ribbon Cables
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
white
brown
green
yellow
grey
pink
blue
red
black
violet
grey/pink
red/blue
white/green
brown/green
white/yellow
yellow/brown
white/grey
grey/brown
white/pink
pink/brown
acc. to DIN VDE 47100
HE 10 20-pole
contact number
Color coding
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
white
brown
green
yellow
grey
pink
blue
red
black
violet
grey/pink
red/blue
white/green
brown/green
white/yellow
yellow/brown
acc. to DIN VDE 47100
HE 10 16-pole
contact number
Color coding
Description Item No.
Pack.
Unit
WAGO ribbon cable, 20-pole/one free
cable end, lenght 2 m
706-100/1300-200 1
Technical Data
Ports 20-pole female connector/one free
cable end
Wire cross-section 0.14 mm
2
LiYY
Color coding acc. to DIN VDE 47100
Current per channel max. 1 A
Operating temperature -25 C ... +70 C
Degree of protection IP20
Length 2 m
Description Item No.
Pack.
Unit
WAGO ribbon cable, 16-pole/one free
cable end, lenght 2 m
706-100/1602-200 1
Technical Data
Ports 16-pole female connector/one free
cable end
Wire cross-section 0.14 mm
2
LiYY
Color coding acc. to DIN VDE 47100
Current per channel max. 1 A
Operating temperature -25 C ... +70 C
Degree of protection IP20
Length 2 m
1
1
67
WAGO Ribbon Cables
1
2
3
4
5
6
7
8
9
10
11
12
13
14
white
brown
green
yellow
grey
pink
blue
red
black
violet
grey/pink
red/blue
white/green
brown/green
acc. to DIN VDE 47100
HE 10 14-pole
contact number
Color coding
1
2
3
4
5
6
7
8
9
10
white
brown
green
yellow
grey
pink
blue
red
black
violet
acc. to DIN VDE 47100
HE 10 10-pole
contact number
Color coding
Description Item No.
Pack.
Unit
WAGO ribbon cable, 14-pole/one free
cable end, lenght 2 m
706-100/1303-200 1
Technical Data
Ports 14-pole female connector/one free
cable end
Wire cross-section 0.14 mm
2
LiYY
Color coding acc. to DIN VDE 47100
Current per channel max. 1 A
Operating temperature -25 C ... +70 C
Degree of protection IP20
Length 2 m
Description Item No.
Pack.
Unit
WAGO ribbon cable, 10-pole/one free
cable end, lenght 2 m
706-100/1301-200 1
Technical Data
Ports 10-pole female connector/one free
cable end
Wire cross-section 0.14 mm
2
LiYY
Color coding acc. to DIN VDE 47100
Current per channel max. 1 A
Operating temperature -25 C ... +70 C
Degree of protection IP20
Length 2 m
1
68
Miniature Switching Relay, Series 857
Pluggable miniature switching relays
1 changeover contact
Pluggable miniature switching relays
1 changeover contact
(gold contacts)
* In order to prevent the gold layer from being damaged
these values should not be exceeded. Higher
switching power leads to evaporation of the gold layer.
The resulting deposits in the enclosure may
cause sparkovers between the coil and the contact.
The values in brackets are valid
if the gold layer is damaged.
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Pluggable miniature switching relays 12 V DC 857-150 20
24 V DC 857-152 20 24 V DC 857-153 20
The 60 V DC replacement relays must be used with
60 V DC, 110 V DC, 220 V DC and 115 V AC/DC,
230 V AC/DC relay modules.
60 V DC 857-155 20 60 V DC 857-157 20
Technical Data
Contact material AgSnO
2
AgSnO
2
+ 5 Au
Max. switching voltage 250 V AC/DC 36 V* DC / (250 V AC/DC)
Max. continuous current (terminal blocks in a row) 6 A 50 mA* / (6 A )
Max. Switching power (resistive) 1250 VA AC (1250 VA AC)*
Recommended minimum load t 100 mA / 12 V AC/DC t 1 V / 1 mA / 50 mW
Max. switching rate with / without load 6 min
-1
/ 20 s
-1
6 min
-1
/ 20 s
-1
Rated power consumption < 220 mW < 220 mW
Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms 5 ms / 6 ms / 5 ms
Nominal operating mode continuous duty continious duty
Dielectric strength contact-coil 4 kV
eff
4 kV
eff
Surge capacity open contact 1 kV
eff
1 kV
eff
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Mechanical life at max. load (resistance) 5 x 10
4
switching operations 5 x 10
4
switching operations
Ambient operating temperature (V
N
) -25 C ... +60 C -25 C ... +60 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 5 x 15 x 28 5 x 15 x 28
Weight 13,5 g 13,5 g
28 mm
1
5
m
m
5 mm
3,8 mm
A1 A2 12 11 14 A1 A2 12 11 14
1
1
69
8
Solid State Relays, 857 Series
Pluggable replacement optocoupler Pluggable replacement optocoupler
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Item No.
Pack.
Unit
Pluggable optocouplers 857-161 20 857-164 20 857-167 20
Technical Data
Control circuit:
Nominal input voltage (V
N
) 24 V DC 24 V DC 24 V DC
Input voltage range 18 V ... 30 V DC 16 V ... 30 V DC 18 V ... 30 V DC
Nominal input current (I
N
) 7 mA 7 mA 7 mA
Load circuit:
Switching voltage 0 V ... 24 V DC 0 V ... 48 V DC 24 V ... 240 V AC
Peak reverse voltage 33 V 54 V 600 V
Max. switching current 2 A DC 100 mA DC 1 A AC
Forward voltage at max. switching current < 120 mV DC < 1 V DC < 1 V AC
Dielectric strength control/switching circuit 2.5 kV 2.5 kV 2.5 kV
General Specifications
Ambient operating temperature -20 C ... +60 C -20 C ... +60 C -20 C ... +60 C
Storage temperature -40 C ... +70 C -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 5 x 15 x 28 5 x 15 x 28 5 x 15 x 28
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Item No.
Pack.
Unit
Pluggable optocouplers 857-162 20 857-165 20 857-168 20
Technical Data
Control circuit:
Nominal input voltage (V
N
) 60 V DC 60 V DC 60 V DC
Input voltage range 35 V ... 72 V DC 52 V ... 72 V DC 35 V ... 72 V DC
Nominal input current (I
N
) 3 mA 2.8 mA 3.1 mA
Load circuit:
Switching voltage 0 V ... 24 V DC 0 V ... 48 V DC 24 V ... 240 V AC
Peak reverse voltage 33 V 54 V 600 V
Max. switching current 2 A DC 100 mA DC 1 A AC
Forward voltage at max. switching current < 120 mV DC < 1 V DC < 1 V AC
Dielectric strength control/switching circuit 2.5 kV 2.5 kV 2.5 kV
General Specifications
Ambient operating temperature -20 C ... +60 C -20 C ... +60 C -20 C ... +60 C
Storage temperature -40 C ... +70 C -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 5 x 15 x 28 5 x 15 x 28 5 x 15 x 28
1
70
Sockets for Miniature Switching Relay and Optocoupler
Sockets for miniature switching relay and
optocoupler
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid: 0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded: 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
<_________ 94 mm/3.68 in _________>
<
_
_
_
_
_
_
8
1
m
m
/
3
.
1
8
i
n
_
_
_
_
_
_
>
____________
12 V DC 857-303 857-103 857-150
24 V DC 857-304 857-104 857-152
48 V DC 857-305 857-105 857-154
60 V DC 857-306 857-106 857-155
110 V DC 857-307 857-107 857-155
220 V DC 857-308 857-108 857-155
24 V AC/DC 857-354 857-104 857-152
115 V AC/DC 857-357 857-107 857-155
230 V AC/DC 857-358 857-108 857-155
24 V DC 857-314 857-104 857-153
110 V DC 857-317 857-107 857-157
220 V DC 857-318 857-108 857-157
24 V AC/DC 857-364 857-104 857-153
115 V AC/DC 857-367 857-107 857-157
230 V AC/DC 857-368 857-108 857-157
24 V DC 857-704 857-104 857-164
115 V AC/DC 857-707 857-107 857-165
230 V AC/DC 857-708 857-108 857-165
24 V DC 857-714 857-104 857-167
115 V AC/DC 857-717 857-107 857-168
230 V AC/DC 857-718 857-108 857-168
24 V DC 857-724 857-104 857-161
115 V AC/DC 857-727 857-107 857-162
230 V AC/DC 857-728 857-108 857-162
M
i
n
i
a
t
u
r
e
S
w
i
t
c
h
i
n
g
R
e
l
a
y
s
(
g
o
l
d
c
o
n
t
a
c
t
s
)
M
i
n
i
a
t
u
r
e
S
w
i
t
c
h
i
n
g
R
e
l
a
y
s
S
o
l
i
d
S
t
a
t
e
R
e
l
a
y
s
Input Voltage Item No. Socket Replacement Relays or
Optocouplers
Assignment Socket / Replacement Relay / Replacement Optocoupler
1
1
71
Accessories, 857 Series
Push-in type jumper bar Commoning
Description Item No. Pack. Unit
Push-in type jumper bars, light gray, insulated, 18 A 2-way 859-402 200 (8x25)
3-way 859-403 200 (8x25)
4-way 859-404 200 (8x25)
5-way 859-405 200 (8x25)
6-way 859-406 100 (4x25)
7-way 859-407 100 (4x25)
8-way 859-408 100 (4x25)
9-way 859-409 100 (4x25)
10-way 859-410 100 (4x25)
Item no. suffix for colored push-in type jumper bars yellow ... /000-029
red ... /000-005
blue ... /000-006
WMB Multi marking system Marking
Description Item No. Pack. Unit
WMB Multi marking system plain 793-501 5 cards
Marking software and printer/plotter see Section 8
Marking 1 ... 10 (10x) 793-502 5 cards
11 ... 20 (10x) 793-503 5 cards
21 ... 30 (10x) 793-504 5 cards
31 ... 40 (10x) 793-505 5 cards
41 ... 50 (10x) 793-506 5 cards
1 ... 50 (2x) 793-566 5 cards
10 strips with 10 markers, white with black printing
Operating tool Wire connection
Description Item No. Pack. Unit
Operating tool, with partially insulated shaft, Type 2, blade (3.5 x 0.5) mm 210-720 1
1
72
Sockets with Miniature Switching Relay
Relay with 1 changeover contact
and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
12 V, 24 V, 48 V, 60 V, 110 V DC
Relay with 2 changeover contact
and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
12 V, 24 V, 48 V, 60 V, 110 V DC
Load limit curve for 788-303 to 788-307, 788-506,
788-507 and 788-508
Note: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay
coils and contacts.
Description V
N
I
N
Item No.
Pack.
unit
V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
12 V DC 36 mA 788-303 1 12 V DC 36 mA 788-311 1
24 V DC 19.1 mA 788-304 1 24 V DC 19.1 mA 788-312 1
48 V DC 11 mA 788-305 1 48 V DC 11 mA 788-313 1
60 V DC 10.5 mA 788-306 1 60 V DC 10.5 mA 788-314 1
110 V DC 6 mA 788-307 1 110 V DC 6 mA 788-315 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgNi 90/10 AgNi 90/10
Input voltage range V
N
10 % V
N
10 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current 16 A 2 x 8 A
Max. make current (resistive) at a 10 % duty cycle 4 s 30 A (AC) 4 s 15 A (AC)
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve 2 x 2 kVA AC, DC see load limit curve
Max. switching rate with / without load 6 min
-1
/ 1200 min
-1
6 min
-1
/ 1200 min
-1
Operating power 400 mW typ. 400 mW typ.
Pull-in/drop-out/bounce time typ. 7 ms / 3 ms / 3 ms 7 ms / 2 ms / 3 ms
Nominal operating mode continious duty continious duty
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 30 x 10
6
switching operations 30 x 10
6
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 54 x 86 15 x 54 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; UL 508
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; UL 508
300
200
100
50
40
30
20
10
0.1 0.2 0.5 1 2 5 10 20
Current (A)
resistive load
V
o
l
t
a
g
e
(
V
)
1
1
73
Zubehr siehe Seite 74 ... 77 + 80 ... 81
Relay with 1 changeover contact
and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
24 V, 115 V, 230 V AC
Relay with 2 changeover contact
and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
AC 24 V, 115 V, 230 V
Load limit curve for 788-311 to 788-315, 788-512,
788-515 and 788-516
Description V
N
I
N
Item No.
Pack.
unit
V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V AC 34 mA 788-506 1 24 V AC 34 mA 788-512 1
115 V AC 8 mA 788-507 1 115 V AC 8 mA 788-515 1
230 V AC 4.3 mA 788-508 1 230 V AC 3 mA 788-516 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgNi 90/10 AgNi 90/10
Input voltage range V
N
10 % V
N
10 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current 16 A 2 x 8 A
Max. make current (resistive) at a 10 % duty cycle 4 s 30 A (AC) 4 s 15 A (AC)
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve 2 x 2 kVA AC, DC see load limit curve
Max. switching rate with / without load 6 min
-1
/ 1200 min
-1
6 min
-1
/ 1200 min
-1
Operating power 0.75 VA 0.75 VA
Pull-in/drop-out/bounce time typ. 7 ms / 3 ms / 3 ms 7 ms / 2 ms / 3 ms
Nominal operating mode continious duty continious duty
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 10 x 10
6
switching operations 5 x 10
6
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 54 x 86 15 x 54 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; g ; UL 508
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; g ; UL 508
ohmsche Last
Schaltstrom (A)
S
c
h
a
l
t
s
p
a
n
n
u
n
g
(
V
)
S
1
74
Sockets with Miniature Switching Relay
Relay with 1 changeover contact
with gold contacts and and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
24 V DC
Relay with 2 changeover contact
with gold contacts and and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
24 V DC
Load limit curve for 788-404, 788-607 and 788-608
* In order to prevent the gold layer from being damaged
these values should not be exceeded. Higher
switching power leads to evaporation of the gold layer.
The resulting deposits in the enclosure may
cause sparkovers between the coil and the contact.
Description V
N
I
N
Item No.
Pack.
unit
V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V DC 19 mA 788-404 1 24 V DC 19 mA 788-412 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgNi + 5 AU AgNi + 5 AU
Input voltage range V
N
10 % V
N
10 %
Max. switching voltage 250 V AC / 36 V DC* 250 V AC / 36 V DC*
Max. continuous current 50 mA* 2 x 50 mA*
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve 2 x 2 kVA AC, DC see load limit curve
Pull-in/drop-out time typ. 7 ms / 3 ms 7 ms / 3 ms
Nominal operating mode continious duty continious duty
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 2.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 3 x 10
7
switching operations 3 x 10
7
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 54 x 86 15 x 54 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
300
200
100
50
40
30
20
10
0.1 0.2 0.5 1 2 5 10 20
Current (A)
resistive load
V
o
l
t
a
g
e
(
V
)
1
1
75
Relay with 1 changeover contact
with gold contacts and and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
115 V, 230 V AC
Relay with 2 changeover contact
with gold contacts and and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
115 V, 230 V AC
Load limit curve for 788-412, 788-615 and 788-616
* In order to prevent the gold layer from being damaged
these values should not be exceeded. Higher
switching power leads to evaporation of the gold layer.
The resulting deposits in the enclosure may
cause sparkovers between the coil and the contact.
Description V
N
I
N
Item No.
Pack.
unit
V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
115 V AC 8.2 mA 788-607 1 115 V AC 8.2 mA 788-615 1
230 V AC 5 mA 788-608 1 230 V AC 5 mA 788-616 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgNi + 5 AU AgNi + 5 AU
Input voltage range V
N
10 % V
N
10 %
Max. switching voltage 250 V AC / 36 V DC* 250 V AC / 36 V DC*
Max. continuous current 50 mA* 2 x 50 mA*
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve 2 x 2 kVA AC, DC see load limit curve
Pull-in/drop-out time typ. 7 ms / 3 ms 7 ms / 3 ms
Nominal operating mode continious duty continious duty
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 2.5 kV 2.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 3 x 10
7
switching operations 3 x 10
7
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 54 x 86 15 x 54 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; g
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; g
2-pole
resistive load
2 contacts in serie
1 contact
Current (A)
V
o
l
t
a
g
e
(
V
)
S
1
76
Sockets with Miniature Switching Relay
Relay with 1 changeover contact
and status indication
(Relay height: 25 mm)
Nominal input voltage V
N
24 V DC
Relay with 2 changeover contact
and status indication
(Relay height: 25 mm)
Nominal input voltage V
N
24 V DC
Load limit curve for 788-324 and 788-528
Description V
N
I
N
Item No.
Pack.
unit
V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V DC 22 mA 788-324 1 24 V DC 22 mA 788-334 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgCdO AgCdO
Input voltage range V
N
10 % V
N
10 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current 16 A 2 x 8 A
Max. make current (resistive) at a 10 % duty cycle 4 s 25 A (AC) 4 s 14 A (AC)
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve 2 x 2 kVA AC, DC see load limit curve
Max. switching rate with / without load 10 min
-1
/ 1200 min
-1
10 min
-1
/ 1200 min
-1
Operating power 500 mW typ. 500 mW typ.
Pull-in/drop-out/bounce time typ. 8 ms / 2 ms / 4 ms 9 ms / 3 ms / 3 ms
Nominal operating mode continious duty continious duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 30 x 10
6
switching operations 20 x 10
6
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 64 x 86 15 x 64 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; UL 508 (max. 40 C)
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; UL 508 (max. 40 C)
300
200
100
50
40
30
20
10
20 ms
40 ms
60 ms
12 A
16 A
8 A
0.1 0.2 0.5 1 2 5 10 20
Current (A)
V
o
l
t
a
g
e
(
V
)
resistive load
1
1
77
Relay with 1 changeover contact
and status indication
(Relay height: 25 mm)
Nominal input voltage V
N
230 V AC
Relay with 2 changeover contact
and status indication
(Relay height: 25 mm)
Nominal input voltage V
N
230 V AC
Load limit curve for 788-334 and 788-538
Description V
N
I
N
Item No.
Pack.
unit
V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
230 V AC 5.6 mA 788-528 1 230 V AC 5.6 mA 788-538 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgCdO AgCdO
Input voltage range V
N
10 % V
N
10 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current 16 A 2 x 8 A
Max. make current (resistive) at a 10 % duty cycle 4 s 14 A (AC) 4 s 14 A (AC)
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve 2 x 2 kVA AC, DC see load limit curve
Max. switching rate with / without load 10 min
-1
/ 1200 min
-1
10 min
-1
/ 1200 min
-1
Operating power 500 mW typ. 500 mW typ.
Pull-in/drop-out/bounce time typ. 8 ms / 2 ms / 4 ms 9 ms / 3 ms / 3 ms
Nominal operating mode continious duty continious duty
Dielectric strength contact-coil 4 kV 4 kV
Dielectric strength open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 30 x 10
6
switching operations 20 x 10
6
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 64 x 86 15 x 64 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; g ;
UL 508 (max. 40 C)
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; g ;
UL 508 (max. 40 C)
300
200
100
50
40
30
20
10
Current (A)
V
o
l
t
a
g
e
(
V
)
0.1 0.2 0.5 1 2 5 10 20
2 contacts in serie
1 contact
resistive load
S
1
78
Sockets with Miniature Switching Relay
Relay with 1 changeover contact
and status indication
(Relay height: 15 mm)
Nominal input voltage V
N
24 V DC
Description V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V DC 19 mA 788-354 1
Technical Data Accessories see pages 86 ... 91
Contact material Ag alloy
Input voltage range U
N
-15 % ... +20 %
Max. switching voltage 250 V AC
Max. continuous current 16 A
Max. make current (resistive) at a 10 % duty cycle (50 ms) 120 A at 230 V AC
Recommended minimum load > 100 mA / 12 V AC/DC
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve
Operating power 400 mW
Pull-in/drop-out/bounce time typ. 15 ms / 5 ms / -
Nominal operating mode continious duty
Dielectric strength contact-coil 5 kV
Dielectric strength open contact 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Mechanical life 10 x 10
6
switching operations
Mechanical life at max. load (resistance) min. 100.000 switching operations
Service life at lamp load see table lamp loads
Degree of protection IP20
Type of relay ALZ
Ambient operating temperature -25 C ... +50 C
Storage temperature -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 54 x 86
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; UL 508
10 100 1000
100
10
1
DC resistive load
AC resistive load
Switching voltage (V)
S
w
i
t
c
h
i
n
g
c
u
r
r
e
n
t
(
A
)
Type of load Capability Electrical life
Incandescent lamp 2200 W 20.000
Halogen lamp 230 V AC 1400 W 50.000
Halogen trafo 120 VA 20.000
Fluorescent lamp not comp., CB, cos 0,4-0,6 20 x 58 W 25.000
Fluorescent lamp comp., Conv. ballast, C parallel 9 x 58 W 25.000
Fluorescent lamp comp., Conv. ballast, Duo-circuit 600 W 20.000
Fluorescent lamp with electronic ballast 12 x 58 W 25.000
Energy saving lamp 15 W 25 pcs 20.000
Energy saving lamp 13 W 30 pcs 20.000
Energy saving lamp 9 W 38 pcs 20.000
Gas discharge lamp 1000 W 20.000
Dulux-Lamp not compensated 800 W 20.000
Dulux-Lamp compensated 500 W 20.000
Max. capacitance at 230 V AC 60 F min. 5.000
1
1
79
Relay with 1 make contact
and status indication
(Relay height: 25 mm)
Nominal input voltage V
N
24 V DC
Description V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V DC 21.8 mA 788-355 1
Technical Data Accessories see pages 86 ... 91
Contact material AgSnO
2
Input voltage range U
N
-15 % ... +20 %
Max. switching voltage 250 V AC
Max. continuous current 16 A
Max. make current (resistive) at a 10 % duty cycle 4 s 25 A (AC)
Peak inrush current 20 ms / 120 A
Recommended minimum load > 100 mA / 12 V AC/DC
Max. Switching power (resistive) 4 kVA AC, DC see load limit curve
Operating power 500 mW
Pull-in/drop-out/bounce time typ. 8 ms / 2 ms / 2 ms
Nominal operating mode continious duty
Dielectric strength contact-coil 4 kV
Dielectric strength open contact 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Mechanical life 30 x 10
6
switching operations
Service life at lamp load see table lamp loads
Degree of protection IP20
Type of relay RP3SL
Ambient operating temperature -25 C ... +50 C
Storage temperature -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 64 x 86
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II; UL 508
0,1 0,2 0,5 1 2 5 10 20
300
200
100
50
40
30
20
10
resistive load
DC current (A)
D
C
v
o
l
t
a
g
e
(
V
d
c
)
Contact life at dierent lamp loads
Load Switching operations
12 A, 250 V AC, cos = 1 3 x 10
5
TV 8 acc. to UL 508 25 x 10
3
2500 W, 230 V AC Halogen lamp > 10
4
1000 W, 250 V AC Incandesent lamp 2.3 x 10
5
3000 W, 250 V AC Incandesent lamp 3.6 x 10
4
1500 VA, Fluorescent lamp 163 F 10
4
13
14
S
1
80
Sockets with Miniature Switching Relay
Safety relay SR2M (2 changeover contacts)
with forced guided contacts and status
indication
(Relay height: 25 mm)
Nominal input voltage V
N
24 V DC
In accordance with EN 50205, it is only permitted to use
1 make contact / 1 break contact for safety circuits
(11-14 and 22-21 or 12-11 and 21-24)
Description V
N
I
N
Item No.
Pack.
unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V DC 31 mA 788-384 1
Technical Data Accessories see pages 86 ... 91
Contact material AgNi
Input voltage range V
N
10 %
Max. switching voltage 250 V AC
Max. continuous current 6 A
Max. make current (resistive) at a 10 % duty cycle 4 s 14 A (AC)
Recommended minimum load > 50 mW
Max. Switching power (resistive) AC 1500 VA; DC see load limit curve
Max. switching rate with / without load 6 min
-1
/ 300 min
-1
Operating power 700 mW
Pull-in/drop-out time typ. 10 ms / 4 ms
Nominal operating mode continious duty
Dielectric strength contact-coil 4 kV
Dielectric strength open contact 1.5 kV
Dielectric strength contact-contact 3 kV
Clearance and creepage distance contact / coil 8 mm
Adjacent contacts 5.5 mm
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Mechanical life 10 x 10
6
switching operations
Degree of protection IP20
Ambient operating temperature -25 C ... +50 C
Storage temperature -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 64 x 86
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Approvals EN 50205; UL 508
300
200
100
50
40
30
20
10
0.1 0.2 0.5 1 2 5 10 20
Current (A)
V
o
l
t
a
g
e
(
V
)
resistive load
1
1
81
S
1
82
Sockets with Miniature Switching Relay
Relay with 1 changeover contact
Electrical and mechanical status indication
Manual operation
(Relay height: 25 mm)
Nominal input voltage V
N
:
24 V DC, 48 V DC, 110 V DC
Relay with 2 changeover contact
Electrical and mechanical status indication
Manual operation
(Relay height: 25 mm)
Nominal input voltage V
N
:
24 V DC, 48 V DC, 110 V DC
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V DC 16.7 mA 788-341 1 24 V DC 16.7 mA 788-346 1
48 V DC 8.3 mA 788-342 1 48 V DC 8.3 mA 788-347 1
110 V DC 3.6 mA 788-344 1 110 V DC 3.6 mA 788-349 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgNi AgNi
Input voltage range U
N
10 % U
N
10 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current 16 A 2 x 8 A
Max. Switching power (resistive) 4 kVA AC 2 x 2 kVA AC
Operating power 400 mW typ. 400 mW typ.
Responce time/Drop-out time max. 15 ms / 8 ms 15 ms / 8 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1 250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 73 x 86 15 x 73 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Standards/Specifications DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
Switching voltage (V)
S
w
i
t
c
h
i
n
g
c
u
r
r
e
n
t
(
A
)
2 change over contacts
1 change over contact
A1
+
A2
-
14
11
12
14
11
12
24
21
22
A1
+
A2
-
1
1
83
Relay with 1 changeover contact
Electrical and mechanical status indication
Manual operation
(Relay height: 25 mm)
Nominal input voltage V
N
:
24 V AC, 115 V AC, 230 V AC
Relay with 2 changeover contact
Electrical and mechanical status indication
Manual operation
(Relay height: 25 mm)
Nominal input voltage V
N
:
24 V AC, 115 V AC, 230 V AC
Similar to illustration Similar to illustration
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay sockets with pluggable miniature switching
relay, for DIN 35 rail
24 V DC 31.6 mA 788-541 1 24 V DC 31.6 mA 788-546 1
115 V AC 6.6 mA 788-543 1 115 V AC 6.6 mA 788-548 1
230 V AC 3.2 mA 788-544 1 230 V AC 3.2 mA 788-549 1
Technical Data Accessories see pages 86 ... 91 Accessories see pages 86 ... 91
Contact material AgNi AgNi
Input voltage range U
N
10 % U
N
10 %
Max. switching voltage 250 V AC 250 V AC
Max. continuous current 16 A 2 x 8 A
Max. Switching power (resistive) 4 kVA AC 2 x 2 kVA AC
Operating power 0.75 VA typ. 0.75 VA typ.
Responce time/Drop-out time max. 15 ms / 8 ms 15 ms / 8 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1 250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
Degree of protection IP20 IP20
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 73 x 86 15 x 73 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Standards/Specifications DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
Switching voltage (V)
S
w
i
t
c
h
i
n
g
c
u
r
r
e
n
t
(
A
)
2 change over contacts
1 change over contact
A1
A2
14
11
12
A1
A2
14
11
12
24
21
22
S
1
84
Relay Sockets with Solid State Relay
Solid state relay
Input: 24 V DC
Output: 0 V ... 24 V DC / 3.5 A
Solid state relay
Input: 24 V DC
Output: 0 V ... 24 V DC / 5 A
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Relay socket with solid state relay, for DIN 35 rail 788-700 1 788-701 1
Technical Data Accessories see pages 89 ... 91 Accessories see pages 89 ... 91
Control circuit:
Nominal input voltage (V
N
) DC 24 V DC 24 V
Input voltage range DC 18 V ... 30 V DC 15 V ... 30 V
Control current U
N
(20C) 7 mA 10 % 9.3 mA 10 %
Release voltage DC 8 V DC 2.5 V
Control circuit resistance 3.2 k 2.1 k
Load circuit:
Load switching voltage range DC 0 ... 24 V DC 0 ... 30 V
Peak reverse voltage 33 V 36 V
Max. switching current DC 3.5 A DC12/DC13 (DC 5 A)
Min. switching current DC 1 mA
Pull-in time 50 s
Drop-out time 600 s
Switching frequency (max.) 100 Hz at 5 A
Forward voltage at max. switching current < DC 0.1 V DC 0.3 V
Nominal operating mode continuous duty continuous duty
Dielectric strength control/switching circuit 2.5 kV 2.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 2.5 kV / 2 250 V / 2.5 kV / 2
Degree of protection IP 20 IP 20
Ambient operating temperature -20 C ... +60C -40 C ... +60C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 53 x 86 15 x 63 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
13 +
A1
+
A2
-
14 -
13 +
A1
+
A2
-
14 -
1
1
85
Solid state relay
Input: 24 V DC
Output: 24 V ... 240 V AC / 1 A
Solid state relay
Input: 24 V AC/DC
Output: 12 275 VAC / 2 A
Zero voltage switch
Description Item No.
Pack.
unit
V
N
I
N
Item No.
Pack.
Unit
Relay socket with solid state relay, for DIN 35 rail 788-720 1 24 V 10 mA 788-721 1
Technical Data Accessories see pages 89 ... 91 Accessories see pages 89 ... 91
Control circuit:
Nominal input voltage (V
N
) 24 V DC 24 V AC/DC
Input voltage range 18 V ... 30 V DC 15 30 VAC
Control current U
N
(20C) 7 mA 10 % 10 mA
Release voltage 4 V DC 2.5 V AC/DC
Control circuit resistance 3.2 k 2.1 k
Load circuit:
Max. switching voltage 240 V AC 275 VAC
Load switching voltage range 24 ... 240 V AC 12 275 VAC (50/60 Hz)
Peak reverse voltage 600 V 600 V
Max. switching current 1 A AC 2A AC
Forward voltage at max. switching current < 1 V AC < 1.1 VAC
Nominal operating mode continuous duty
Dielectric strength control/switching circuit 3.75 kV 4 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 2.5 kV / 2
250 V / 2.5 kV / 2
Degree of protection IP 20 IP20
Ambient operating temperature -20 C ... +60C -20 C ... +60 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 15 x 53 x 86 15 x 53 x 86
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
A1
+
A2
-
13
14
14 ( ) Last
A1
A2
13 (L)
S
1
86
Accessories, 788 Series
Pluggable miniature switching relays
(Relay height: 15 mm)
1 changeover contact
Pluggable miniature switching relays
(Relay height: 15 mm)
2 changeover contact
Description V
N
Item No.
Pack.
unit
V
N
Item No.
Pack.
unit
Pluggable miniature switching relays 12 V DC 788-150 20 12 V DC 788-152 20
24 V DC 788-154 20 24 V DC 788-156 20
48 V DC 788-158 20 48 V DC 788-160 20
60 V DC 788-162 20 60 V DC 788-164 20
110 V DC 788-166 20 110 V DC 788-168 20
24 V AC 788-170 20 24 V AC 788-172 20
115 V AC 788-174 20 115 V AC 788-176 20
230 V AC 788-178 20 230 V AC 788-180 20
Technical Data
Contact material AgNi AgNi
Switching current 16 A 2 x 8 A
Inrush current 30 A 15 A
Max. switching voltage 250 V AC 250 V AC
Switching power 4 kVA 2 kVA
Min. switching current 10 mA 10 mA
Nominal consumption, typ 400 mW 400 mW
Pull-in/drop-out time typ. 7 ms / 3 ms 7 ms / 3 ms
Nominal operating mode continious duty continious duty
Mechanical life AC coil > 10 x 10
6
switching operations > 5 x 10
6
switching operations
Mechanical life DC coil > 30 x 10
6
switching operations > 30 x 10
6
switching operations
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 2.5 kV
Weight approx. 13.5 g approx. 13.3 g
Degree of protection IP40 IP40
Ambient operating temperature AC coil -40 C ... +70 C -40 C ... +70 C
Ambient operating temperature DC coil -40 C ... +85 C -40 C ... +85 C
Flammability acc. to UL 94 V0 V0
Relay height 15 mm
29.0 12.7
1
5
.
7
3
.
8
Pinning 5 mm Pinning 5 mm
1
1
87
Pluggable miniature switching relays
(Relay height: 15 mm)
1 changeover contact (gold contacts)
Pluggable miniature switching relays
(Relay height: 15 mm)
2 changeover contact (gold contacts)
Description V
N
Item No.
Pack.
unit
V
N
Item No.
Pack.
unit
Pluggable miniature switching relays 24 V DC 788-155 20 24 V DC 788-157 20
115 V AC 788-175 20 115 V AC 788-177 20
230 V AC 788-179 20 230 V AC 788-181 20
Technical Data
Contact material AgNi + 5 m Au AgNi + 5 m Au
Switching current 50 mA* 2 x 50 mA*
Max. switching voltage 36 V* DC 36 V* DC
Switching power min. 50 mW min. 50 mW
Rated power consumption 200 mW DC 200 mW DC
Rated power consumption 0.422 VA AC 0.422 VA AC
Pull-in/drop-out time typ. 7 ms / 3 ms 7 ms / 3 ms
Nominal operating mode continious duty continious duty
Mechanical life AC coil > 3 x 10
7
switching operations > 3 x 10
7
switching operations
Mechanical life DC coil > 3 x 10
7
switching operations > 3 x 10
7
switching operations
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 2.5 kV
Weight approx. 11 g approx. 15 g
Degree of protection IP40 IP40
Ambient operating temperature AC coil -40 C ... +70 C -40 C ... +70 C
Ambient operating temperature DC coil -40 C ... +85 C -40 C ... +85 C
Flammability acc. to UL 94 V0 V0
Relay height 15 mm
29.0 12.7
1
5
.
7
3
.
8
Pinning 5 mm Pinning 5 mm
S
1
88
Accessories, 788 Series
Pluggable miniature switching relays
(Relay height: 25 mm)
1 changeover contact
Pluggable miniature switching relays
(Relay height: 25 mm)
2 changeover contact
Description V
N
Item No.
Pack.
unit
V
N
Item No.
Pack.
unit
Pluggable miniature switching relays 12 V DC 788-182 20 12 V DC 788-183 20
24 V DC 788-184 20 24 V DC 788-185 20
48 V DC 788-186 20 48 V DC 788-187 20
60 V DC 788-188 20 60 V DC 788-189 20
110 V DC 788-190 20 110 V DC 788-191 20
230 V AC 788-192 20 230 V AC 788-193 20
Technical Data
Contact material AgNi
AgSnO (788-192)
AgNi
AgSnO (788-193)
Switching current 16 A 2 x 8 A
Max. switching voltage 250 V AC 250 V AC
Switching power 4 kVA 2 kVA
Min. switching current 100 mA 10 mA
Rated power consumption 500 mW DC 500 mW DC
Rated power consumption 1.2 VA AC 1.2 VA AC
Pull-in/drop-out time typ. 9 ms / 3 ms 9 ms / 3 ms
Nominal operating mode continious duty continious duty
Mechanical life AC coil > 10 x 10
6
switching operations > 10 x 10
6
switching operations
Mechanical life DC coil > 20 x 10
6
switching operations > 20 x 10
6
switching operations
Dielectric strength contact-coil 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 2.5 kV
Weight approx. 18 g approx. 18 g
Degree of protection IP40 IP40
Ambient operating temperature AC coil -40 C ... +70 C -40 C ... +70 C
Ambient operating temperature DC coil -40 C ... +85 C -40 C ... +85 C
Flammability acc. to UL 94 V0 V0
Relay height 25 mm
29.0 12.7
2
5
.
5
3
.
3
Pinning 5 mm Pinning 5 mm
1
1
89
Sockets for Miniature Switching Relay
Sockets for miniature switching relay
1 changeover contact / 2 changeover contact
Description Item No.
Pack.
unit
Socket without relay, for DIN 35 rail
Relay height 15 mm, 1 changeover contact 788-100 1
Relay height 15 mm, 2 changeover contacts 788-102 1
Relay height 25 mm, 1 changeover contact 788-101 1
Relay height 25 mm, 2 changeover contacts 788-103 1
Technical Data
Max. continuous current 16 A / 2 x 8 A
Nominal input voltage (V
N
) depending on relay; max. 250 V AC
Dielectric strength 5 kV (depending on relay)
Max. switching voltage 250 V AC
Max. Switching power (resistive) 4000 VA AC
Nominal operating mode continious duty
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Degree of protection IP20
Ambient operating temperature -25 C ... +70 C (depending on relay)
Storage temperature -40 C ... +80 C
Wire connection CAGE CLAMP
S
Cross sections 0.34 mm ... 2.5 mm / AWG 22 ... 12
Stripped lengths 9 ... 10 mm / 0.37 in
Approvals DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160,
EN 50178; degree of protection II
1 changeover contact 2 changeover contacts
View on pins
Pinning
S
1
90
Accessories, 788 Series
Status indication
Description Power consumption at V
N
Item No. Pack. Unit
Status indication 24 V DC (12 V ... 24 V) 2.4 mA 788-120 50 (2x25)
Status indication 48 V DC (48 V ... 60 V) 1.9 mA 788-121 50 (2x25)
Status indication 110 V DC 1.9 mA 788-122 50 (2x25)
Status indication 24 V AC 2.1 mA 788-123 50 (2x25)
Status indication 115 V AC 1.7 mA 788-124 50 (2x25)
Status indication 230 V AC 1.6 mA 788-125 50 (2x25)
Push-in type jumper bar
788-113 Commoning Push-in type jumper bar
Description Item No. Pack. Unit
Push-in type jumper bar, I max. 18 A 2-way (module/module) 788-113 200 (8x25)
3-way 788-114 100 (4x25)
4-way 788-115 100 (4x25)
6-way 788-116 100 (4x25)
8-way 788-117 100 (4x25)
Push-in type jumper bars, light gray, insulated,
18 A
2-way (intern) 859-402 200 (8x25)
WMB Multi marking system Marking Group marker carrier
Description Item No. Pack. Unit
WMB Multi marking system plain 793-501 5 cards
Marking software and printer/plotter see Section 8
Marking 1 ... 10 (10x) 793-502 5 cards
11 ... 20 (10x) 793-503 5 cards
21 ... 30 (10x) 793-504 5 cards
31 ... 40 (10x) 793-505 5 cards
41 ... 50 (10x) 793-506 5 cards
1 ... 50 (2x) 793-566 5 cards
10 strips with 10 markers, white with black printing
Group marker carrier 209-112 50 (1x50)
1
1
91
Operating tool Wire connection
Description Item No. Pack. Unit
Operating tool, with partially insulated shaft Type 2, blade (3.5 x 0.5) mm 210-720 1
Ferrule
Description Sleeve for mm
2
/ AWG Item No. Pack. Unit
Ferrule, red insulated, 12 mm 2 x 1 mm
2
/ 2 x 18 216-542 500
1
92
Sockets with Industrial Relay
Socket with industrial relay
Coil voltage: 24 V DC
4 changeover contacts
Socket with industrial relay
Coil voltage: 24 V DC
4 changeover contacts (gold contacts)
* In order to prevent the gold layer from being damaged,
these values shall not be exceeded. Higher switching
power leads to evaporation of the gold layer. The resulting
deposits in the enclosure may cause sparkovers between
the coil and the contact.
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Relay socket with industrial relay, for DIN 35 rail 858-304 1 858-314 1
Technical Data Accessories see pages 96 ... 98 Accessories see pages 96 ... 98
Coil
Coil voltage 24 V DC 24 V DC
Rated power 0.9 W 0.9 W
Coil current 36.9 mA 36.9 mA
Operating range 0.8 ... 1.1 x V 0.8 ... 1.1 x V
Holding voltage 50 % of V
N
50 % of V
N
Release voltage 0.1 x V 0.1 x V
Contacts
Contact material AgCe AgCe + 5 m Au
Continuous current 5 A 50 mA*
Inrush current 15 A / 4 s 15 A / 4 s
Max. switching voltage 250 V AC / 30 V DC 30 V DC*
Switching power (max.) AC1 / AC15 1250 VA / 300 VA 1250 VA / 300 VA
1-phase motor load AC3 0.12 kW 0.12 kW
Switching current (max.) DC1 5 A at 30 V DC 5 A at 30 V DC
Min. switching load 12 V / 100 mA 12 V / 100 mA
Switching frequency under load 20 cycles/min. 20 cycles/min.
General Specifications
Mechanical life 20 x 10
6
switching operations 20 x 10
6
switching operations
Electrical life 1 x 10
5
switching operations 1 x 10
5
switching operations
Pull-in/drop-out/bounce time typ. 25 ms / 25 ms / 4 ms 25 ms / 25 ms / 4 ms
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 2.5 kV / 2 250 V / 2.5 kV / 2
Dielectric strength contact-coil (1.2/50 s) 4 kV 4 kV
Dielectric strength contact-coil (AC, 1 min) 1.5 kV 1.5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 1.5 kV 1.5 kV
Ambient operating temperature -25 C ... +70 C (V
L
+ 50 C) -25 C ... +70 C (V
L
+ 50 C)
Storage temperature -40 C ... +80 C -40 C ... +80 C
Dimensions (mm) W x H x L 31 x 73 x 97 31 x 73 x 97
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2.5 mm/
AWG 22 ... 16
2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2.5 mm/
AWG 22 ... 16
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
14
34
24
44
12
32
22
42
11
31
21
41
A1
-
A2
+
14
34
24
44
12
32
22
42
11
31
21
41
A1
-
A2
+
1
1
93
Socket with industrial relay
Coil voltage: 230 V AC
4 changeover contacts
Socket with industrial relay
Coil voltage: 230 V AC
4 changeover contacts (gold contacts)
* In order to prevent the gold layer from being damaged,
these values shall not be exceeded. Higher switching
power leads to evaporation of the gold layer. The resulting
deposits in the enclosure may cause sparkovers between
the coil and the contact.
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Relay socket with industrial relay, for DIN 35 rail 858-508 1 858-518 1
Technical Data Accessories see pages 96 ... 98 Accessories see pages 96 ... 98
Coil
Coil voltage 230 V AC 230 V AC
Rated power 1.2 VA 1.2 VA
Coil current 8.3 mA 8.3 mA
Operating range 0.8 ... 1.1 x V 0.8 ... 1.1 x V
Holding voltage 80 % of V
N
80 % of V
N
Release voltage 0.3 x V 0.3 x V
Contacts
Contact material AgCe AgCe + 5 m Au
Continuous current 5 A 50 mA*
Inrush current 15 A / 4 s 15 A / 4 s
Max. switching voltage 250 V AC / 30 V DC 30 V DC*
Switching power (max.) AC1 / AC15 1250 VA / 300 VA 1250 VA / 300 VA
1-phase motor load AC3 0.12 kW 0.12 kW
Switching current (max.) DC1 5 A at 30 V DC 5 A at 30 V DC
Min. switching load 12 V / 100 mA 12 V / 100 mA
Switching frequency under load 20 cycles/min. 20 cycles/min.
General Specifications
Mechanical life 20 x 10
6
switching operations 20 x 10
6
switching operations
Electrical life 1 x 10
5
switching operations 1 x 10
5
switching operations
Pull-in/drop-out/bounce time typ. 25 ms / 25 ms / 4 ms 25 ms / 25 ms / 4 ms
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 2.5 kV / 2 250 V / 2.5 kV / 2
Dielectric strength contact-coil (1.2/50 s) 4 kV 4 kV
Dielectric strength contact-coil (AC, 1 min) 1.5 kV 1.5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 1.5 kV 1.5 kV
Ambient operating temperature -25 C ... +70 C (V
L
+ 50 C) -25 C ... +70 C (V
L
+ 50 C)
Storage temperature -40 C ... +80 C -40 C ... +80 C
Dimensions (mm) W x H x L 31 x 73 x 97 31 x 73 x 97
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2.5 mm/
AWG 22 ... 16
2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2.5 mm/
AWG 22 ... 16
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
14
34
24
44
12
32
22
42
11
31
21
41
A1
~
A2
~
14
34
24
44
12
32
22
42
11
31
21
41
A1
~
A2
~
S
1
94
Relay Sockets with Industrial Relay
Relay sockets with industrial relay
Coil voltage:
24 VDC, 110 VDC, 220 VDC
4 changeover contacts
Description V
N
I
N
Item No.
Pack.
Unit
Relay socket with industrial relay,
for DIN 35 rail
24 VDC 31.5 mA 858-390 1
110 VDC 7.7 mA 858-392 1
220 VDC 4.3 mA 858-391 1
Technical Data Accessories see pages 96 ... 98
Coil
Input voltage range U
N
-10 % ... +30 %
Contacts
Contact material AgNi 90/10
Max. continuous current 4 x 6 A
Max. make current (resistive) at a 10 % duty cycle 12 A / 20 ms
Max. switching voltage 240 VAC
Max. Switching power (resistive) 4 AC x 1500 VA, DC see load curve
Recommended minimum load 12 V / 10 mA
Pull-in/drop-out/bounce time typ. 15 ms / 18 ms / 8 ms
Mechanical life 30 x 10
6
switching operations
General specifications:
Nominal voltage acc. to IEC 60664-1 250 V / 2.5 kV / 2
Dielectric strength contact-coil 2.5 kV
eff
Surge capacity open contact 1.2 kV
eff
Dielectric strength contact-contact (AC, 1 min.) 2 kV
eff
Ambient operating temperature (V
N
) -40 C ... +70 C
Storage temperature -40 C ... +85 C
Dimensions (mm) W x H x L 31 x 55 x 97
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S
Cross sections 2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2,5 mm
AWG 22 ... 16
Stripped lengths 9 ... 10 mm / 0.37 in
Standards/Specifications EN 61810-1, EN 60664-1
(OT = On-time)
14
34
24
44
12
32
22
42
11
31
21
41
A1
+
A2
-
1
1
95
Relay Sockets with Industrial Relay
Relay sockets with industrial relay
Coil voltage:
24 VDC, 48 VDC, 110 VDC, 220 VDC
2 changeover contacts
Relay socket with industrial relay
Coil voltage:
AC 230 V
2 changeover contacts
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay socket with industrial relay,
for DIN 35 rail
24 VDC 37.5 mA 858-324 1 230 VAC 11 mA 858-528 8
48 VDC 18.5 mA 858-325 8
110 VDC 8.1 mA 858-327 8
220 VDC 4.1 mA 858-328 8
Technical Data Accessories see pages 96 ... 98 Accessories see pages 96 ... 98
Coil
Input voltage range U
N
-20 % ... +10 % U
N
-20 % ... +10 %
Contacts
Contact material AgNi AgNi
Max. continuous current 2 x 12 A 2 x 12 A
Max. make current (resistive) at a 10 % duty cycle 24 A / 4 s 24 A / 4 s
Max. switching voltage 250 VAC 250 VAC
Max. Switching power (resistive) 2 AC x 3000 VA, DC see load curve 2 AC x 3000 VA, DC see load curve
Recommended minimum load 5 V / 5 mA / 0.3 W 5 V / 5 mA / 0.3 W
Pull-in/drop-out/bounce time typ. 13 ms / 3 ms 10 ms / 8 ms
Mechanical life 2 x 10
7
switching operations 2 x 10
7
switching operations
General specifications:
Nominal voltage acc. to IEC 60664-1 250 V / 4 kV / 2 250 V / 4 kV / 2
Dielectric strength contact-coil 2.5 kV
eff
2.5 kV
eff
Surge capacity open contact 1.5 kV
eff
1.5 kV
eff
Dielectric strength contact-contact (AC, 1 min.) 2.5 kV
eff
2.5 kV
eff
Ambient operating temperature (V
N
) -40 C ... +70 C -40 C ... +55 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 31 x 73 x 97
Height from upper-edge of DIN 35 rail
31 x 73 x 97
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S CAGE CLAMP
S
Cross sections 2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2.5 mm/
AWG 22 ... 16
2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2.5 mm/
AWG 22 ... 16
Stripped lengths 9 ... 10 mm / 0.37 in 9 ... 10 mm / 0.37 in
Standards/Specifications EN 61810-1, EN 60664-1 EN 61810-1, EN 60664-1
(OT = On-time)
24
14
22
12
21
11
A1
+
A2
-
24
14
22
12
21
11
A1
A2
S
1
96
Accessories, 858 Series
Pluggable industrial relays, 4 changeover
contacts with integrated LED and recovery
diode and manual operation
Pluggable industrial relays, 4 changeover
contacts with integrated LED and manual
operation
* In order to prevent the gold layerfrom being
damaged these values should not be exceeded.
Higher switching power leads to evaporation of the
gold layer. The resulting deposits in the endosure may
cause sparkover between the coil and the contact.
Description V
N
Item No.
Pack.
unit
V
N
Item No.
Pack.
unit
Pluggable industrial relay 24 V DC 858-150 1 240 V AC 858-151 1
24 V DC* 858-152 1 240 V AC* 858-153 1
Technical Data
Coil
Coil voltage 24 V DC 240 V AC
Rated power 0.9 W 1.2 VA
Coil current 36.9 mA 8.3 mA
Operating range 0.8 ... 1.1 x V 0.8 ... 1.1 x V
Holding voltage 50 % of V
N
80 % of V
N
Release voltage 0.1 x V 0.3 x V
Contacts
Contact material AgCe, AgCe + 5 m Au*AgCe, AgCe + 5 m Au* AgCe, AgCe + 5 m Au*
Continuous current 5 A * 5 A *
Inrush current 15 A / 4 s 15 A / 4 s
Max. switching voltage 250 V AC / 30 V DC 250 V AC / 30 V DC
Switching power (max.) AC1 / AC15 1250 VA / 300 VA 1250 VA / 300 VA
1-phase motor load AC3 0.12 kW 0.12 kW
Switching current (max.) DC1 5 A at 30 V DC 5 A at 30 V DC
Min. switching load 12 V / 100 mA 12 V / 100 mA
Switching frequency under load 20 cycles/min. 20 cycles/min.
General Specifications
Mechanical life 20 x 10
6
switching operations 20 x 10
6
switching operations
Electrical life 1 x 10
5
switching operations 1 x 10
5
switching operations
Pull-in/drop-out/bounce time typ. 25 ms / 25 ms / 4 ms 25 ms / 25 ms / 4 ms
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 2 kV / 2 250 V / 2 kV / 2
Dielectric strength contact-coil (1.2/50 s) 4 kV 4 kV
Dielectric strength contact-coil (AC, 1 min) 1.5 kV 1.5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 1.5 kV 1.5 kV
Ambient operating temperature -25C ... +70C -25C ... +70C
Mounting distance in a row 6 mm 6 mm
Weight approx. 37 g approx. 37 g
28 max 21,5 max
3
5
m
a
x
5
,8
13.2
4.4
6
.4
1
2
.7
1
6
.8
6
.3
1 2 3 4
5 6 7 8
9 10 11 12
13 14
13.2
4.4
6
.4
1
2
.7
1
6
.8
6
.3
1 2 3 4
5 6 7 8
9 10 11 12
13 14
1
1
97
Sockets with Industrial Relay
Socket for industrial relays 2 and 4
changeover contacts
Note: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay
coils and contacts.
Description Item No.
Pack.
Unit
Relay socket for industrial relays, for DIN 35 rail 858-100 1
Technical Data
Nominal input voltage (V
N
) depending on Relay; max. 250 V AC
Max. switching voltage 250 V AC
Max. continuous current 4 x 8 A (4 changeover contacts);
2 x 12 A (2 changeover contacts)
Max. Switching power (resistive) 4000 VA AC
Nominal operating mode continious duty
Dielectric strength 4 kV (depending on relay)
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Degree of protection IP 20
Ambient operating temperature -25 C ... +70 C (depending on relay)
Storage temperature -40 C ... +80 C
Dimensions (mm) W x H x L 31 x 39 x 97
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S
Stripped lengths 9 ... 10 mm / 0.37 in
Cross sections 2 x 0.34 mm ... 2 x 1.5 mm /
1 x 2.5 mm/
AWG 22 ... 16
Approvals IEC60664 / IEC60664A / DIN VDE0110
Degree of pollution 2
Overvoltage category 2
41
31
21
11
44
34
24
14
42
32
22
12
A1
A2
1
98
Accessories, 858 Series
Holding bracket
Description Item No. Pack. unit
Holding bracket for industrial relays (height 33.5 mm ... 35.5 mm) 858-110 1
Push-in type jumper bar
Description Item No. Pack. unit
Push-in type jumper bar 858-402 200
Status indication
Description Power consumption at V
N
Item No. Pack. Unit
Status indication 24 V DC (12 V ... 24 V) 2.4 mA 788-120 50 (2x25)
Status indication 48 V DC (48 V ... 60 V) 1.9 mA 788-121 50 (2x25)
Status indication 110 V DC 1.9 mA 788-122 50 (2x25)
Status indication 24 V AC 2.1 mA 788-123 50 (2x25)
Status indication 115 V AC 1.7 mA 788-124 50 (2x25)
Status indication 230 V AC 1.6 mA 788-125 50 (2x25)
NOTE:
Only required when using relays without integrated operating indicator!
Operating tool
Description Item No. Pack. unit
Operating tool, with partially insulated shaft Type 2, blade (3.5 x 0.5) mm 210-720 1
1
1
99
1
100
Rail Mounted Relay Modules
Relay with 1 make contact Relay direct
soldered with universal mounting carrier
Relay with 1 break contact Relay direct
soldered with universal mounting carrier
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Switching relay module 24 V DC 16 mA 288-364 1 24 V DC 16 mA 288-368 1
24 V AC/DC 16 mA 288-564 1 24 V AC/DC 16 mA 288-568 1
48 V AC/DC 9.1 mA 288-565 1
115 V AC/DC 4.4 mA 288-567 1
Technical Data
Contact material AgNi 0.15 + HV AgNi 0.15 + HV
Max. switching voltage 250 V DC / 250 V AC 250 V DC / 250 V AC
Max. make / break current 4 s 16 A / 8 A 4 s 16 A / 8 A
Max. continuous current 5 A 5 A
Max. switching power (resistive) 100 W/ 1500 VA 100 W/ 1500 VA
Pull-in / operating power 240 mW / 500 mW 240 mW / 500 mW
Pull-in/drop-out/bounce time typ. 4 ms / 6 ms / 2 ms 4 ms / 6 ms / 2 ms
Dielectric strength contact-coil (AC, 1 min) 4 kV 4 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 30 x 10
6
switching operations 30 x 10
6
switching operations
Mechanical life at max. load (resistance) 2 x 10
5
switching operations 2 x 10
5
switching operations
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Dimensions (mm) L x W x H
incl. mounting carrier and relay
13 x 47 x 85 13 x 47 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
Size I with
2 changeover contacts
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Relay socket, for AC/DC relays 288-111 1 288-131 1
Relay socket, for DC relays with free-wheeling diode 288-112 1 288-132 1
Relay socket, for DC relays with free-wheeling diode
and LED
288-113 1 288-133 1
Technical Data
Relay enclosure 14-pole 8-pole
Operating voltage (dependent on the relay voltage) max. 250 V AC/DC max. 250 V AC/DC
Nominal current 5 A 5 A
Max. coil current of the LED version 25 mA 25 mA
Dimensions (mm) L x W x H incl. mounting carrier and
universal mounting feet
42.5 x 32 x 62.5 42.5 x 32 x 62.5
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
Size II with
4 changeover contacts
Description Item No.
Pack.
Unit
Relay socket, for AC/DC relays 288-151 1
Relay socket, for DC relays with free-wheeling diode 288-152 1
Relay socket, for DC relays with free-wheeling diode
and LED
288-153 1
Technical Data
Relay enclosure 14-pole
Operating voltage (dependent on the relay voltage) max. 250 V AC/DC
Nominal current 5 A
Max. coil current of the LED version 25 mA
Dimensions (mm) L x W x H incl. mounting carrier and
universal mounting feet
42.5 x 32 x 62.5
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
A1
+
A2
A2
RL
1
+
3
2
A1
+
A2
A2
1
1
129
Optocoupler
Input 230 V AC
Output 5 V, 15 V, 24 V DC/500 mA
Negative switching
Module width 15 mm / 0.591 in
Optocoupler
Input 230 V AC
Output 5 V, 15 V, 24 V DC/500 mA
Positive switching
Module width 15 mm / 0.591 in
WSB marker cards
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking A1, A2, A2, 1, 3, 2, A1, A2, A2;
Item No.: 209-685
5 cards, each containing 10 strips with 10 markers
Description Output Item No.
Pack.
Unit
Output Item No.
Pack.
Unit
Optocoupler module 5 V DC (3.5 V ... 7 V DC) 286-704 1 5 V DC (3.5 V ... 7 V DC) 286-754 1
15 V DC (10 V ... 20 V DC) 286-706 1 15 V DC (10 V ... 20 V DC) 286-756 1
24 V DC (20 V ... 30 V DC) 286-708 1 24 V DC (20 V ... 30 V DC) 286-758 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal input voltage (V
N
) 230 V AC 230 V AC
Input voltage range 40 V ... 250 V AC 40 V ... 250 V AC
Input current range 0.2 mA ... 2.9 mA AC 0.2 mA ... 2.9 mA AC
Current at nominal voltage 2.6 mA AC 2.6 mA AC
Reverse voltage transistor / Triac 80 V DC 80 V DC
Max. permissible continuous current 500 mA 500 mA
Switch on / Switch off time < 10 ms / < 50 ms < 10 ms / < 40 ms
Leakage current at nominal voltage 2.5 A 2.5 A
Collector / emitter voltage drop Vce sat d 1.2 V d 1.2 V
Max. output (reverse current) 5 mA ; 6 mA ; 5 mA 5 mA ; 7.5 mA ; 7.5 mA
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-619 1 17 mm / 0.669 in 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-609 1 17 mm / 0.669 in 280-609 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in 280-763 1 20 mm/ 0.787 in 280-763 1
RL
1
+
3
2
A1
~
A2
~
A2
~
RL
1
+
3
2
A1
~
A2
~
A2
~
1
130
Pluggable Modules - Optocouplers
Optocoupler
Input 24 V DC
Output 24 V DC/2 A
Negative switching
Module width 15 mm / 0.591 in
Optocoupler
Input 24 V DC
Output 24 V DC/5 A
Negative switching
Module width 15 mm / 0.591 in
WSB marker cards
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking A1, A2, A2, 1, 3, 2, A1, A2, A2;
Item No.: 209-685
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Optocoupler module 286-720 1 286-721 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal input voltage (V
N
) 24 V DC 24 V DC
Input voltage range 15 V ... 30 V DC 15 V ... 30 V DC
Input current range 7.5 mA ... 18 mA DC 7.5 mA ... 18 mA DC
Current at nominal voltage 13.5 mA DC 13.5 mA DC
Output nominal voltage 24 V DC 24 V DC
Output voltage range 15 V ... 40 V DC 15 V ... 40 V DC
Reverse voltage transistor / Triac 50 V DC 50 V DC
Max. permissible continuous current 2 A 5 A
Switch on / Switch off time < 15 s / < 40 s < 20 s / < 80 s
Max. operating frequency 1 kHz 1 kHz
Leakage current at nominal voltage 2.5 A 2.5 A
Collector / emitter voltage drop Vce sat d 0.5 V d 0.5 V
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-619 1 17 mm / 0.669 in 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-609 1 17 mm / 0.669 in 280-609 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in 280-763 1 20 mm/ 0.787 in 280-763 1
RL
1
+
3
2
A1
+
A2
A2
RL
1
+
3
2
A1
+
A2
A2
1
1
131
Optocoupler
Input 5 V DC
Output 24 V DC/500 mA
Positive switching
Module width 15 mm / 0.591 in
Optocoupler
Input 24 V DC
Output 24 V DC/4 A
Positive switching
Module width 15 mm / 0.591 in
WSB marker cards
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking A1, A2, A2, 1, 3, 2, A1, A2, A2;
Item No.: 209-685
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Optocoupler module 286-752/002-000 1 286-723 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal input voltage (V
N
) 5 V DC 24 V DC
Input voltage range 2 V ... 6.25 V DC 15 V ... 30 V DC
Input current range 3.3 mA ... > 18.5 mA 7.9 mA ... 18 mA DC
Current at nominal voltage 14 mA DC 14 mA DC
Output nominal voltage 24 V DC 24 V DC
Output voltage range 20 V ... 30 V DC 20 V ... 30 V DC
Reverse voltage transistor / Triac 80 V DC 100 V DC
Max. permissible continuous current 500 mA 4 A at 6 R
Switch on / Switch off time < 5 s / < 10 s d 15 s / d 25 s
Max. operating frequency 25 kHz 5 kHz
Leakage current at nominal voltage 2.5 A 2.5 A
Collector / emitter voltage drop Vce sat d 1.2 V d 1.2 V
Max. output (reverse current) 12 mA 12 mA
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Approvals IEC 60664 / IEC 60664A / DIN VDE 0110;
pollution degree 2;
overvoltage category III
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules, w
ith 2-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-619 1 17 mm / 0.669 in 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-609 1 17 mm / 0.669 in 280-609 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in 280-763 1 20 mm/ 0.787 in 280-763 1
RL
1
+
3
2
A1
+
A2
A2
RL
1
+
3
2
A1
+
A2
A2
1
132
Pluggable Modules - Optocouplers
Optocoupler
Input 5 V DC 12 V DC 24 V DC
Output 110 V DC/1.6 A
Negative switching
Module width 15 mm / 0.591 in
Optocoupler
Input 5 V DC 12 V DC 24 V DC
Output 230 V AC/50 mA ... 1 A
Module width 15 mm / 0.591 in
WSB marker cards
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking A1, A2, A2, 1, 3, 2, A1, A2, A2;
Item No.: 209-685
Marking A1, A2, A2, 1, 2, 2, A1, A2, A2;
Item No.: 209-686
5 cards, each containing 10 strips with 10 markers
Description Input Item No.
Pack.
Unit
Input Item No.
Pack.
Unit
Optocoupler module 5 V DC (4.5 V ... 6,5 V DC) 286-726 1 5 V DC (3.5 V ... 7.5 V DC) 286-732 1
12 V DC (10 V ... 20 V DC) 286-728 1 12 V DC (9 V ... 18 V DC) 286-733 1
24 V DC (15 V ... 30 V DC) 286-730 1 24 V DC (10 V ... 30 V DC) 286-734 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Input current range 6.5 mA ... 20 mA DC
4 mA ... 12 mA DC
3.5 mA ... 8 mA DC
0.5 mA ... 17 mA DC
4 mA ... 11 mA DC
2 mA ... 8 mA DC
Current at nominal voltage 6.5 mA DC
6.4 mA DC
6.2 mA DC
6 mA DC
Output nominal voltage 110 V DC 230 V AC
Output voltage range 99 V ... 121 V DC 24 V ... 280 V AC
Reverse voltage transistor / Triac 150 V DC 600 V AC
Max. permissible continuous current 1.6 A at 69 R 1 A
Switch on / Switch off time d 20 s / d 0.5 ms 1 half-wave ms / 1 half-wave ms
Max. operating frequency 350 Hz
Leakage current at nominal voltage 3 A 5 mA
Collector / emitter voltage drop Vce sat d 0.5 V
Voltage drop at output < 1.7 V AC
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-619 1 17 mm / 0.669 in 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-609 1 17 mm / 0.669 in 280-609 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in 280-763 1 20 mm/ 0.787 in 280-763 1
RL
1
+
3
2
A1
+
A2
A2
~
RL
1
2
2
A1
+
A2
A2
~
~
~
Z
e
r
o
V
o
lt
s
w
i
t
c
h
1
1
133
Optocoupler
Input 10 V ... 30 V AC/DC
Output 24 V DC/1 mA ... 0.5 A
Negative switching
Module width 15 mm / 0.591 in
Optocoupler
Input 24 V DC
Output 60 V DC/100 mA
Module width 10 mm / 0.394 in
WSB marker cards
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking A1, A2, A2, 1, 3, 2, A1, A2, A2;
Item No.: 209-685
Marking A1, A2, A2, 1, 2, 2, A1, A2, A2;
Item No.: 209-686
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Optocoupler module 286-725 1 286-791 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal input voltage (V
N
) 10 V ... 30 V AC/DC 24 V DC
Input voltage range 10 V ... 30 V AC/DC 15 V ... 30 V DC
Input current range 2 mA ... 7 mA AC/DC 7.5 mA ... 18 mA DC
Current at nominal voltage 14 mA
Output nominal voltage 24 V DC 60 V DC
Output voltage range 20 V ... 30 V DC 20 V ... 60 V DC
Reverse voltage transistor / Triac 80 V DC 80 V DC
Max. permissible continuous current 500 mA 100 mA
Switch on / Switch off time < 5 ms / < 30 ms 10 s / 50 s
Max. operating frequency 3 kHz
Leakage current at nominal voltage max. 2.5 A 2.5 A
Collector / emitter voltage drop Vce sat d 1 V
Max. output (reverse current) 6.5 mA ... 10 mA DC
Voltage drop at output d 2 V
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-619 1 12 mm / 0.472 in 280-618 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in 280-609 1 12 mm / 0.472 in 280-608 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in 280-763 1 15 mm / 0.591 in 280-762 1
RL
1
+
3
2
A1
~
A2
~
A2
~
RL
1
+
2
A1
+
A2
1
134
Pluggable Modules - Optocouplers
Optocoupler
Input 24 V DC
Output 60 V DC/100 mA
Module width 10 mm / 0.394 in
Dual channel optocoupler
2 inputs 2 x 24 V DC
2 outputs 2 x 24 V DC/2 x 250 mA
Module width 20 mm / 0.787 in
WSB marker cards
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking A1, A2, A2, 1, 2, 2, A1, A2, A2;
Item No.: 209-686
Marking A1+, A1+, A2-, A2-, 1, RL1, Rl2, 2;
Item No.: 209-955
Marking A1+, A1+, A2-, A2-, 1+, 1+, A, 2-;
Item No.: 249-651
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Optocoupler module 286-794 1 286-792 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal input voltage (V
N
) 24 V DC 24 V DC
Input voltage range 18 V ... 30 V DC 7.5 V ... 30 V DC
Input current range 2 mA ... 5 mA DC 4 mA ... 19 mA DC
Current at nominal voltage 4 mA DC 15 mA DC
Output nominal voltage 60 V DC 24 V DC
Output voltage range 20 V ... 60 V DC 20 V ... 30 V DC
Reverse voltage transistor / Triac 80 V DC 80 V DC
Max. permissible continuous current 100 mA 250 mA
Switch on / Switch off time 80 s / 100 s < 60 s / < 120 s
Max. operating frequency 1.5 kHz 1.5 kHz
Leakage current at nominal voltage 2.5 A 2.6 A
Collector / emitter voltage drop Vce sat < 2.5 V
Voltage drop at output d 2 V
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +60 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 12 mm / 0.472 in 280-618 1 22 mm / 0.866 in 280-638 1
with 4-conductor terminal blocks, orange separator 12 mm / 0.472 in 280-608 1 22 mm / 0.866 in 280-628 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
15 mm / 0.591 in 280-762 1 25 mm / 0.984 in 280-764 1
RL
1
+
2
A1
+
A2
RL
RL
A1
+
A2
A2
A1
+
1
+
2
3
+
4
1
1
135
Optocoupler with 2 inverted outputs
Input 24 V DC
Output 2 x 24 V DC/500 mA
Module width 20 mm / 0.787 in
Optocoupler with bridge plug and
programmable outputs
Input 24 V DC
Output 24 V DC,
Short-circuit protected, positive switching
Module width 20 mm/ 0.787 in
286-938:
Optocoupler module with short-circuit protected, positive
switching output.
Two sockets with plug for programming the output.
Independent of the input signal the output can be switched
over to H (high) or L (low) by means of a bridge plug
(supplied with the module).
The short-circuit protected output is equipped with a current
limiter which limits load currents above 800 mA to
200 mA.
The maximum operating time of the current limiter is 60 s.
Status indication:
Input green LED
Output yellow LED
Short circuit red LED
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Optocoupler module 286-790 1 286-938 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal input voltage (V
N
) 24 V DC 24 V DC
Input voltage range 20 V ... 30 V DC 10 V ... 30 V DC
Input current range 7 mA ... 12 mA DC 4 mA ... 19 mA DC
Current at nominal voltage 9 mA DC 14 mA DC
Output nominal voltage 24 V DC 24 V DC
Output voltage range 20 V ... 30 V DC 20 V ... 30 V DC
Reverse voltage transistor / Triac 100 V DC 50 V DC
Max. permissible continuous current 500 mA 300 mA (800 mA max. 30 s)
Switch on / Switch off time 4 s / 15 s < 5 s / < 25 s
Max. operating frequency 2.5 kHz 20 kHz at 80 R
Leakage current at nominal voltage 2.5 A < 1 A
Collector / emitter voltage drop Vce sat < 1.2 V < 1.1 V
Max. output (reverse current) 5.5 mA (Input high, output low);
3 mA (Input low, output low);
11 mA (Output high) programmed
with bridge plug
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 22 mm / 0.866 in 280-638 1 22 mm / 0.866 in 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in 280-628 1 22 mm / 0.866 in 280-628 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
25 mm / 0.984 in 280-764 1 25 mm / 0.984 in 280-764 1
1+
A1
+
1
A2
A1
+
A2
RL1
RL2
2
RL
1
+
A1
+
A2
A1
+
A2
1
+
A
H
L
1
136
Pluggable Modules - S0 Optocouplers
Power optocoupler
for S0 current meter interface
with AC output
Module width 20 mm / 0.787 in
Power optocoupler
for S0 current meter interface
with DC output
Module width 20 mm / 0.787 in
The optocoupler for the S0 current meter interface sends
counter pulses from the supply lines.
Via this interface the user has the possibility to access data
which is created by pulse generating current meters with a
S0 current meter interface in accordance with DIN 43
864. The user can extract the data without affecting the S0
circuit and use them for their own evaluations, for example,
optimizing energy consumption by reducing peak
demands.
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
S0 interface 286-740 1 286-741 1
Terminal block for pluggable modules, with shunt
resistance
22 mm /
0.866 in wide
286-740/001-000 1 22 mm /
0.866 in wide
286-740/001-000 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Input current 1-Signal (H) > 10 mA ... < 27 mA > 10 mA ... < 27 mA
Input current 0-Signal (L) < 2 mA < 2 mA
Switch-on treshold > 8.5 mA > 8.5 mA
Switch-off treshold < 7 mA < 7 mA
Transmission frequency <100 Hz
Input wiring reverse protection diode reverse protection diode
Operating voltage range 24 V ... 280 V (50 Hz ... 60 Hz) AC 15 V ... 120 V DC
Peak reverse voltage 600 V AC 200 V DC
Continuous current 2 x 1 A 2 x 750 mA
Surge current t = 20 ms 60 A 3 A
Min. load current 30 mA
Voltage drop at I max < 1.2 V < 1.2 V
Leakage current when turned off < 2 mA
Switch on / Switch off time 10 ms / 10 ms 5 ms / 3 ms
Output circuit RC module / varistor suppressor diode
Test voltage input / output 2.5 kV eff. 2.5 kV eff.
Wire connection CAGE CLAMP
CAGE CLAMP
Ambient operating temperature -25 C ... +60 C (at 0.4 A continuous current) -25 C ... +60 C (at 200 mA continuous current)
Storage temperature -40 C ... +80 C -40 C ... +80 C
Approvals DIN VDE 0110 DIN VDE 0110
Mounting position any any
Dimensions (mm) L x H x W incl. terminal block 20 x 82.5 x 73 20 x 82.5 x 73
1
3
14
A1
+
A2
23
24
1
3
14
A1
+
A2
23
24
1
1
137
Pluggable Modules - S0 Optocouplers
Supply module
for passive S0 current meter interface
Module width 25 mm / 0.984 in
This compact module supplies power to passive S0 current
meter interfaces.
Description Item No.
Pack.
Unit
S0 supply module 286-742 1
Technical Data Accessories see pages 150 ... 151
Nominal input voltage (V
N
) 230 V AC
Frequency 50 Hz
Max. output voltage DC (acc. to DIN 43 864) 27 V
Max. output current (acc. to DIN 43 864) 27 mA
Switch on / Switch off time
Test voltage input / output 2.5 kV eff.
Ambient operating temperature 0 C ... +70 C
Storage temperature -40 C ... +80 C
Approvals IEC 60664/ IEC 60664A/ DIN VDE 0110;
IEC 60742/ EN 60742/ VDE 0551
Mounting position any
Dimensions (mm) L x H x W incl. terminal block 25 x 82.5 x 73
Accessories Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 4-conductor terminal blocks, orange separator 27 mm /
1.063 in wide
280-629 1
Wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
Stripped lengths 8 ... 9 mm / 0.33 in
WSB marker card with marking: +/- 209-552 5
Current meter
Power
supply
Passive
S0 interface
Module for
S0 interface
Supply line
(pulse counted)
Power supply
for passiv
S0 interface
L1 N
Supply voltage
Display
PLC
2 electri-
cally isola-
ted outputs
L
N
+
1
138
Pluggable Modules - NAMUR Switching Amplifiers
NAMUR switching amplifier with relay output
(the switching amplifier has got an isolated
output, e.g. for the connection of a PLC)
Module width 20 mm / 0.787 in
NAMUR switching amplifier with relay output
(the electronic output VA provides the status of
the NAMUR sensor)
Module width 20 mm / 0.787 in
NAMUR switching amplifier for the supply of NAMUR
sensors and the evaluation and amplification of the sensor
signals in accordance with DIN 19234 and DIN 50 227.
A line break or a sensor short circuit are monitored by the
module and indicated via LEDs.
LED 1 yellow: Line break
LED 2 yellow: Short circuit
LED 3 red: Output active
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
NAMUR switching amplifier 286-880 1 286-881 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Supply voltage V
B
24 V DC ( 10 %) 24 V DC ( 10 %)
Nominal input current 20 mA 20 mA
Input 2-wire NAMUR proximity sensor 2-wire NAMUR proximity sensor
Nominal voltage 8 V DC 8 V DC
Current limitation 8 mA 8 mA
Signal current (1) t 2 mA t 2 mA
Signal current (0) d 1.7 mA d 1.7 mA
Switching delay 10 ms 10 ms
Max. operating frequency 50 Hz
Short circuit monitoring I t 7 mA I t 7 mA
Line break monitoring I d 0.2 mA I d 0.2 mA
Output relay 1 changeover contact transistor
Contact material AgNi 0.15
Max. switching voltage 250 V AC / 120 V DC 24 V DC
Switching current 3 A 0.5 A
Output voltage VA 22 V 10 %
Max. breaking capacity (resistive) 750 VA AC; DC see load limit curve
Recommended minimum load 100 mA / 10 V AC/DC ( 1 W, 1VA)
Pull-in/drop-out/bounce time typ. 8 ms / 5 ms / 4 ms 8 ms / 5 ms / 4 ms
Dielectric strength contact-coil (AC, 1 min) 4 kV
Dielectric strength open contact 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Mechanical life 1 x 10
8
switching operations
Mechanical life at max. load (resistance) 3 x 10
5
switching operations
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Approvals DIN VDE 0160 and IEC 60255, DIN VDE 0435
(corresponding parts) DIN 19234, DIN 50227
DIN VDE 0160 and IEC 60255, DIN VDE 0435
(corresponding parts) DIN 19234, DIN 50227
0 1 2 3 4 5 6
120
100
80
60
40
20
0
Current (A)
V
o
l
t
a
g
e
(
V
)
24 V
12
+
1 2 3
UV
14
11
11
0 V
Sensor
24 V
+
UA
+
0 V
0 V
1 2 3
UV
Sensor
1
1
139
Pluggable Modules - Switches
1-pole changeover
with changeover rocker switch
Module width 15 mm / 0.591 in
1-pole changeover
with momentary switch
Module width 15 mm / 0.591 in
WSB marker card
Marking S; Item No.: 209-682
Marking 1 ... 10; Item No.: 209-702
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Switching module 286-895 1 286-896 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Max. switching voltage 24 V DC / 250 V AC 24 V DC / 250 V AC
Switching current, resistive 6 A AC 6 A AC
Switching current, inductive 4 A AC 4 A AC
Electrical life t 50.000 switching operations t 50.000 switching operations
Contact gap t 3 mm t 3 mm
Isolation voltage 1250 V 1250 V
Ambient operating temperature -20 C ... +40 C -20 C ... +40 C
Approvals Switch tested acc. to EN 61058-1 Switch tested acc. to EN 61058-1
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-619 1 17 mm / 0.669 in wide 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-609 1 17 mm / 0.669 in wide 280-609 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in wide 280-763 1 20 mm/ 0.787 in wide 280-763 1
1
2
3
1
2
3
1
2
3
1
2
3
1
140
Pluggable Modules - Current Flow Monitoring
AC/DC current flow monitoring module
15 mA DC/35 mA ... 300 mA AC
Module width 20 mm / 0.787 in
AC current flow monitoring module
80 mA ... 6 A
Module width 20 mm / 0.787 in
WSB marker card
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking Lin, Lin, Lout, Lout, 24V, UA, UA, 0V;
Item No.: 209-957
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Current flow monitoring module 286-659 1 286-661 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Current monitoring range 15 mA DC / 35 mA ... 300 mA AC
Current < 15/35 mA Output 24 V DC
Current > 15/35 mA Output 0 V
80 mA ... 6 A AC
Current < 80 mA Output 24 V DC
Current > 80 mA Output 0 V
Voltage range 10 V ... 250 V AC/DC 5 V ... 250 V AC
Nominal power consumption min / max 45 mW / 900 mW 1 mVA / 2.8 VA
Voltage drop 3 V 13 mV ... 460 mV
Response time 5 ms 40 ms
Operating voltage 24 V DC 24 V DC
Power consumption 61 mA 41 mA
Switching current 50 mA 50 mA
Switching voltage 24 V DC 24 V DC
Switching power 1.2 W 1.2 W
Dielectric strength input / output 2 kV 2 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Status indication Operation: LED = green output LOW, current interruption:
LED = red output HIGH
Operation: LED = green output LOW, current interruption:
LED = red output HIGH
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-638 1 22 mm / 0.866 in wide 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-628 1 22 mm / 0.866 in wide 280-628 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
25 mm / 0.984 in wide 280-764 1 25 mm / 0.984 in wide 280-764 1
L
IN
DC/AC
L
OUT
U
I
I
+24V
0V
Output
I
AC
L
OUT
L
IN
+24V
0V
Output
1
1
141
Pluggable Modules - Current Flow Monitoring
DC current flow monitoring module
0.4 A ... 3.5 A 1 make contact
Module width 15 mm / 0.591 in
AC current flow monitoring module
0.2 A ... 3 A, adjustable (286-664)
1 A ... 10 A, adjustable (286-665)
1 changeover contact (1 u)
Module width 25 mm / 0.984 in
WSB marker card
Marking U; Item No.: 209-789
Marking 1 ... 10; Item No.: 209-702
Marking Lin, Lin, Lout, 11, 14, 14, Lin, Lin, Lout;
Item No.: 249-654
Marking Lin, Lin, Lout, Lout, 24V, 11, 12, 14, 0V;
Item No.: 209-997
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Current flow monitoring module 286-662 1 286-664 1
286-665 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Current monitoring range 0.4 A ... 3.5 A DC (-20 C ... +40 C);
0.4 A ... 3 A DC (-20 C ... +60 C);
0.4 A ... 2 A DC (-20 C ... +70 C)
0.2 A ... 3 A AC (286-664)
1 A ... 10 A AC (286-665)
Voltage range 12 V ... 28 V DC
Nominal power consumption min / max 45 mW / 630 mW 9 mVA / 1.3 VA (286-664)
23 mVA / 8.5 VA (286-665)
Switching treshold min. 0.2 A (adjustable) (286-664)
min. 1 A (adjustable) (286-665)
Turn on / off point 0.35 A / 0.07 A
Voltage drop 24 mV ... 210 mV 44 mV ... 430 mV (286-664)
23 mV ... 850 mV (286-665)
Response time 0.5 ms 300 ms (286-664)
200 ms (286-665)
Output 1 make contact 1 changeover contact
Operating voltage 24 V DC
Power consumption 17 mA (286-664)
28 mA (286-665)
Switching current 0.5 A 5 A
Switching voltage 200 V DC 250 V AC
Switching power 10 W 1250 VA
Dielectric strength input / output 1.5 kV 1.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 2.5 kV / 2
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +70 C
Status indication Current < switching treshold LED red, Relay switched
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-619 1 27 mm / 1.063 in wide 280-639 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-609 1 27 mm / 1.063 in wide 280-629 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in wide 280-763 1 30 mm / 1.181 in wide 280-765 1
I
I
I
11
14
14
I
I
I
I
+24V
11
12
14
0V
I
U
1
142
Pluggable Modules - Bridge Rectifiers
Bridge with varistor protection for input
voltage 24 V AC/1 A
Module width 15 mm / 0.591 in
Bridge with varistor protection for input
voltage 250 V AC/1 A
Module width 15 mm / 0.591 in
WSB marker card
Marking V; Item No.: 209-784
Marking 1 ... 10; Item No.: 209-702
Marking +/-; Item No.: 209-652
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Bridge rectifiers 286-830 1 286-840 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Input voltage 24 V AC 250 V AC
Nominal current 1 A 1 A
Current pulse limit 10 A (10 ms) 10 A (10 ms)
Max. charging capacitor 2200 F 500 F
Max. nominal operating voltage input (Varistor) 35 V 250 V
Max. nominal operating voltage output (Varistor) 60 V 300 V
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-619 1 17 mm / 0.669 in wide 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-609 1 17 mm / 0.669 in wide 280-609 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in wide 280-763 1 20 mm/ 0.787 in wide 280-763 1
~
~
+
~
~
+
1
1
143
Bridge rectifier for input voltage
250 V AC/1 A
Module width 10 mm / 0.394 in
Description Item No.
Pack.
Unit
Bridge rectifiers 280-804/281-419 1
Technical Data Accessories see pages 150 ... 151
Input voltage 250 V AC
Nominal current 1 A
Max. charging capacitor 500 F
Ambient operating temperature -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-618 1
with 4-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-608 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
15 mm / 0.591 in wide 280-762 1
~
~
+
1
144
Pluggable Modules - Fuses
Fuse modules for replaceable microfuses
5 x 20 mm; max. 6.3 A
with blown fuse indication LED green
24 V AC/DC
Module width 10 mm / 0.394 in
Fuse modules for replaceable microfuses
5 x 20 mm; max. 6.3 A
with blown fuse indication Neon lamp
230 V AC/DC
Module width 10 mm / 0.394 in
WSB marker card
Marking F1 ... F10; Item No.: 209-787
Marking 1 ... 10; Item No.: 209-702
Marking +/-; Item No.: 209-652
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Fuse module, with blown fuse indication 286-890 1 286-891 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Operating voltage 24 V AC/DC 230 V AC/DC
Max. fuse capacity 6.3 A 6.3 A
Operating power 100 mW 100 mW
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Leakage current in case of blown fuse 5 mA 0.5 mA
Test voltage 2.5 kV 2.5 kV
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-618 1 12 mm / 0.472 in wide 280-618 1
with 4-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-608 1 12 mm / 0.472 in wide 280-608 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
15 mm / 0.591 in wide 280-762 1 15 mm / 0.591 in wide 280-762 1
+
1
1
145
Pluggable Modules - Diode Gates
Diode gate module
with 3, 5, 7 or 9 diodes 1 N 4007,
common anode
Module width see Item No.
Diode gate module
with 3, 5, 7 or 9 diodes 1 N 4007,
common cathode
Module width see Item No.
WSB marker card
Marking V; Item No.: 209-784
Marking 1 ... 10; Item No.: 209-702
Marking +/-; Item No.: 209-652
5 cards, each containing 10 strips with 10 markers
Description Module width Item No.
Pack.
Unit
Module width Item No.
Pack.
Unit
Diode gate module with 3 diodes 10 mm / 0.394 in 286-803 1 10 mm / 0.394 in 286-813 1
with 5 diodes 15 mm / 0.591 in 286-805 1 15 mm / 0.591 in 286-815 1
with 7 diodes 20 mm / 0.787 in 286-807 1 20 mm / 0.787 in 286-817 1
with 9 diodes 25 mm / 0.984 in 286-809 1 25 mm / 0.984 in 286-819 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Operating voltage 250 V AC/DC 250 V AC/DC
Peak reverse voltage 1000 V 1000 V
Rectified current for each diode, resistive 1 A 1 A
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-618 1 12 mm / 0.472 in wide 280-618 1
with 4-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-608 1 12 mm / 0.472 in wide 280-608 1
with 4-conductor terminal blocks, marker plate 15 mm / 0.591 in wide 280-762 1 15 mm / 0.591 in wide 280-762 1
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-619 1 17 mm / 0.669 in wide 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-609 1 17 mm / 0.669 in wide 280-609 1
with 4-conductor terminal blocks, marker plate 20 mm / 0.787 in wide 280-763 1 20 mm/ 0.787 in wide 280-763 1
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-638 1 22 mm / 0.866 in wide 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-628 1 22 mm / 0.866 in wide 280-628 1
with 4-conductor terminal blocks, marker plate 25 mm / 0.984 in wide 280-764 1 25 mm / 0.984 in wide 280-764 1
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 27 mm / 1.063 in wide 280-639 1 27 mm / 1.063 in wide 280-639 1
with 4-conductor terminal blocks, orange separator 27 mm / 1.063 in wide 280-629 1 27 mm / 1.063 in wide 280-629 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
30 mm / 1.181 in wide 280-765 1 30 mm / 1.181 in wide 280-765 1
1
2
5
6
9
10
1
2
5
6
9
10
1
146
Pluggable Modules - AND Gate and LED Indicator
AND gate module
with 6 inputs
Relay output with 1 make contact
Module width 25 mm / 0.984 in
LED indicator module
with 8 LED, common cathode
Module width 25 mm / 0.984 in
WSB marker card
Marking D; Item No.: 209-783
Marking 1 ... 10; Item No.: 209-702
Marking +, -, 1, 2, 3, 13, 14, 4, 5, 6;
Item No.: 249-608
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Gate module 286-826 1 286-822 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Operating voltage 24 V DC 24 V DC
Operating voltage range 24 V ... 27.5 V DC 20 V ... 26 V DC
Gate voltage - input DC 24 V
Power consumption at V
N
max. 34.6 mA 5.1 mA each LED
Relay output make contact
Max. switching voltage 250 V AC / 120 V DC
Max. continuous current 3 A
Max. Switching power (resistive) 120 W / 750 VA
Dielectric strength input / output 2.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 27 mm / 1.063 in wide 280-639 1 27 mm / 1.063 in wide 280-639 1
with 4-conductor terminal blocks, orange separator 27 mm / 1.063 in wide 280-629 1 27 mm / 1.063 in wide 280-629 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
30 mm / 1.181 in wide 280-765 1 30 mm / 1.181 in wide 280-765 1
+
1
2
3
13
14
4
5
6
E1
E6
& A
1
2
3
4
0
5
6
7
8
0
1
1
147
Pluggable Modules - Flip-Flop
Flip-Flop
Operating voltage 24 V DC
Module width 15 mm / 0.591 in
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Flip Flop module 286-825 1
Technical Data Accessories see pages 150 ... 151
Input voltage 24 V DC ( 10 %)
Input current 0.25 mA
Input voltage (High Signal) > 7 V
Input voltage (Low Signal) < 3 V
Pulse frequency 5 kHz
Min. output voltage V
B
- 1.5 V
Max. output current 0.5 A
Operating voltage 24 V DC
Operating voltage range 20 V ... 30 V DC
Power consumption 7.5 mA
Reverse voltage transistor 80 V
Test voltage input/output 2.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Ambient operating temperature 0 C ... +55 C
Accessories Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-609 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
20 mm/ 0.787 in wide 280-763 1
0V
IN
0V
OUT
24V
1
148
Pluggable Modules - Fault Indication
Fault indicator module with reset
Alarm with continuous light with outputs for
visible and audible warning
Auxiliary and fault indication voltage 230 V
AC
Fault indicator module with reset
Alarm with continuous light with outputs for
visible and audible warning
Extensible to collective fault indicator by
means of diode gates Auxiliary and fault
indication voltage 60 V DC
Accessories for collective fault indication (for 286-684)
Diode gate 286-813 to 286-819
Diode gate 289-111 with common cathode,
WSB marker card
Marking D; Item No.: 209-783
Marking 1 ... 10; Item No.: 209-702
Marking L, N, Quitt, Str, A1, A2, Test, N, 14, 24;
Item No.: 249-606
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Fault indicator module with reset 286-681 1 286-684 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal voltage 230 V AC 60 V DC / RW d 6%
Tolerance -10 % ... +5 % 10 %
Power consumption 15 mA 9 mA
Output for visible warning 230 V AC / 0.5 A 60 V DC / 0.5 A
Output for audible warning 230 V AC/2 A electrically isolated make contact
Max. switching voltage 250 V AC
Max. switching current 2 A
Max. switching capacity 500 VA
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-638 1 22 mm / 0.866 in wide 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-628 1 22 mm / 0.866 in wide 280-628 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
25 mm / 0.984 in wide 280-764 1 25 mm / 0.984 in wide 280-764 1
Explanation of signs
Audiable warning
Visible warning
out on
out permanent
light
Fault
Visible warning
Audiable warning
Reset
Test
AC 230 V
L
N N
14
24
Reset
Fault
Test
DC 60 V
DC 60 V
L
N
Test
from
diode gate
Reset
Fault
1
1
149
Fault indicator module with reset
Indication of original fault with single flashing
light
Output for audible warning
Visible warning by LED Extensible to collective
fault indicator by means of diode gates
Accessories for collective fault indication
Diode gate 286-813 to 286-819
Diode gate 289-111 with common cathode
WSB marker card
Marking D; Item No.: 209-783
Marking 1 ... 10; Item No.: 209-702
Marking A1, A2, Quitt, Str, 12, 11, 11, 14;
Item No.: 249-653
5 cards, each containing 10 strips with 10 markers
Description Item No.
Pack.
Unit
Fault indicator module with reset 286-683 1
Technical Data Accessories see pages 150 ... 151
Nominal voltage 24 V DC / RW d 6%
Tolerance 10 %
Power consumption 25 mA
Flashing frequency LED (yellow) 1 Hz
Relay output 1 electrically isolated changeover contact
Max. switching voltage 250 V AC / 120 V DC
Max. switching current 5 A
Max. switching capacity 120 W / 1250 VA
Contact material AgNi 0.15
Dielectric strength contact-coil (AC, 1 min) 2.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C
Accessories Item No.
Pack.
Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-628 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
25 mm / 0.984 in wide 280-764 1
12
11
14
Fault
LED yellow
LED red
Relay
Reset
Explanation of signs
Visible warning
out permanent ashing
light
can be used with diode gate
A1
A2
Reset
Fault
Fault 1
Fault n
14
DC 24 V
11
12 A1+
A2-
from
diode gate
Reset
Fault
1
150
Overview Pluggable Modules Switching Relays
with an extended input voltage and operating temperature range V
N
-30 % ... +25 % Ambient operating temperature -25 C ... +70 C
Switching relay module
Description
Nominal Input
Voltage (V
N
)
Input Voltage Range Max. Switching Voltage Module Width Item No.
Pack.
Unit
Switching relay module, Relay
with 1 changeover contact
24 V DC V
N
-30 % ...+25 % 250 V AC/DC 15 mm / 0.591 in 286-304/004-000 1
Relay with 1 changeover contact 110 V DC V
N
-30 % ...+25 % 250 V AC/DC 15 mm / 0.591 in 286-307/004-000 1
Relay with 2 changeover
contacts
24 V DC V
N
-30 % ...+25 % 250 V AC / 200 V DC 20 mm / 0.787 in 286-312/004-000 1
Relay with 1 break contact and 1
make contact 24 V DC V
N
-30 % ...+25 % 250 V AC / 200 V DC 20 mm / 0.787 in 286-320/004-000 1
Relay with 2 make contacts 24 V DC V
N
-30 % ...+25 % 250 V AC / 200 V DC 20 mm / 0.787 in 286-328/004-000 1
Relais with 2 make contacts and
2 make contacts 24 V DC V
N
-30 % ...+25 % 250 V AC / 200 V DC 25 mm / 0.984 in 286-336/001-000 1
Relay with 3 make contacts and
1 break contact 24 V DC V
N
-30 % ...+25 % 250 V AC / 200 V DC 25 mm / 0.984 in 286-344/004-000 1
Relay with 4 make contacts 24 V DC V
N
-30 % ...+25 % 250 V AC / 30 V DC 25 mm / 0.984 in 286-352/004-000 1
Relay with 1 make contact 24 V DC V
N
-30 % ...+25 % 250 V AC 10 mm / 0.394 in 286-364/004-000 1
Relay with 1 changeover contact 24 V DC V
N
-30 % ...+25 % 36 V DC 15 mm / 0.591 in 286-394/004-000 1
Time relay (on-delay timing) with
1 changeover contact 24 V DC V
N
-30 % ...+25 % 250 V AC / 200 V DC 20 mm / 0.787 in 286-604/004-000 1
Multifunction timing relay with1
changeover contact 24 V DC V
N
-30 % ...+25 % 250 V AC / 120 V DC 20 mm / 0.787 in 286-640/004-000 1
Relay with 1 break contact and 1
make contact 24 V DC V
N
-30 % ...+25 % 250 V AC / 250 V DC 15 mm / 0.591 in 286-906/004-000 1
For additional technical data see: www.wago.com
2-conductor terminal block 4-conductor terminal block
Description Item No. Pack. Unit
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-618 1
with 4-conductor terminal blocks, orange separator 12 mm / 0.472 in wide 280-608 1
with 4-conductor terminal blocks, marker plate 15 mm / 0.591 in wide 280-762 1
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-619 1
with 4-conductor terminal blocks, orange separator 17 mm / 0.669 in wide 280-609 1
with 4-conductor terminal blocks, marker plate 20 mm / 0.787 in wide 280-763 1
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in wide 280-628 1
with 4-conductor terminal blocks, marker plate 25 mm / 0.984 in wide 280-764 1
Terminal block for pluggable modules,
with 2-conductor terminal blocks, orange separator 27 mm / 1.063 in wide 280-639 1
with 4-conductor terminal blocks, orange separator 27 mm / 1.063 in wide 280-629 1
with 4-conductor terminal blocks, marker plate 30 mm / 1.181 in wide 280-765 1
Terminal block for pluggable modules,
with 4-conductor terminal blocks, orange separator 37 mm / 1.457 in wide 280-636 1
Wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14; Stripped lengths 8 ... 9 mm / 0.33 in
1
1
151
WSB Marker Cards
Miniature quick marking card
Description Item No. Pack. Unit
Marking: K 209-782 5 cards
1 ... 10 (10 x) 209-702 5 cards
A1, A2, 13, 14 209-952 5 cards
A1, A2, 11, 12 209-953 5 cards
11, 12, 14, A1, A2, A2, 11, 12, 14 209-994 5 cards
12, A1, A2, 24, 11, 14, 21, 22 209-995 5 cards
A1, A1, A2, A2, 11, 12, 13, 14, 23, 24 209-693 5 cards
12, A1, A2, 23, 24, 11, 13, 14, 21, 22 209-691 5 cards
12, A1, A2, 23, 24, 11, 13, 14, 33, 34 209-690 5 cards
14, A1, A2, 33, 34, 13, 23, 24, 43, 44 209-692 5 cards
A1, A2, 32, 31, 34, 42, 41, 12, 11, 14, 22, 21, 24, 44 249-656 5 cards
L+, 1, L-, L-, 11, 12, 13, 14 209-954 5 cards
A1, A2, A3, 11, 12, 14 249-607 5 cards
A1, A1, A2, A2, 12, 11, 11, 14 209-996 5 cards
A1, A1, St, A2, A2, 12, 11, 11, 14 209-601 5 cards
U1, U2, U3, U4, 0V, 12, 11, 11, 14, 14 209-951 5 cards
U 209-789 5 cards
A1, A2, A2, 1, 3, 2 209-685 5 cards
A1, A2, A2, 1, 2, 2 209-686 5 cards
A1+, A1+, A2-, A2-, 1, RL1, RL2, 2 209-955 5 cards
A1+, A1+, A2-, A2-, 1+, 1+, A, 2- 249-651 5 cards
+/- 209-552 5 cards
1, 2, 3, 0V, +UB, OUT, ERR., 0V 249-622 5 cards
1, 2, 0V, +UB, OUT, ERR., 0V 249-623 5 cards
Lin, Lin, Lout, Lout, 24V, UA, UA, 0V 209-957 5 cards
Lin, Lin, Lout, 11, 14, 14, Lin, Lin, Lout 249-654 5 cards
Iin, Iin, Iout, Iout, 24V, 11, 12, 14, 0V 209-997 5 cards
S 209-682 5 cards
V 209-784 5 cards
F1 ... F10 209-787 5 cards
D 209-783 5 cards
+, -, 1, 2, 3, 13, 14, 4, 5, 6 249-608 5 cards
L, N, Quitt, Strung, Test, N, 14, 24 249-606 5 cards
A1, A2, Quitt, Strung, 12, 11, 11, 14 249-653 5 cards
5 cards, each containing 10 strips with 10 markers
Colored marker cards
Description Item No. Pack. Unit
Marker cards and tags WSB 4 mm/0.157 in (plain) white 209-701 5 cards
Marking software and printer/plotter see Section 8 yellow 209-701/000-002 5 cards
red 209-701/000-005 5 cards
blue 209-701/000-006 5 cards
gray 209-701/000-007 5 cards
orange 209-701/000-012 5 cards
light green 209-701/000-017 5 cards
green 209-701/000-023 5 cards
violet 209-701/000-024 5 cards
5 cards, each containing 10 strips with 10 markers
1
152
Relay Modules in DIN-Rail Mounted Enclosure
Relay with 1 changeover contact (1 u)
Nominal input voltage V
N
24 V DC
Relay with 1 changeover contact (1 u)
Nominal input voltage V
N
24 V DC, 230 V AC/DC
Other coil voltages contact factory
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay modules in DIN-rail mounted enclosure, for
DIN 35 rail
24 V DC 19 mA 789-304 1 24 V AC/DC 20 mA 789-504 1
230 V AC 4.2 mA 789-508 1
Technical Data Accessories see page 162 Accessories see page 162
Contact material AgNi 90/10 AgNi 90/10
Input voltage range V
N
-15 % ... +10 % V
N
-15 % ... +10 %
Max. switching voltage 250 V AC/DC 250 V AC/DC
Max. make current (resistive) at a 10 % duty cycle 4 s 25 A (AC) 4 s 25 A (AC)
Max. continuous current 12 A 12 A
Max. Switching power (resistive) 3000 VA AC, DC see load limit curve 3000 VA AC, DC see load limit curve
Recommended minimum load > 100 mA / 12 V AC/DC > 100 mA / 12 V AC/DC
Operating power 400 mW 0.96 VA
Pull-in/drop-out/bounce time typ. 7 ms / 3 ms / 3 ms 15 ms / 15 ms / 3 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil (AC, 1 min) 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life at 1000 W, AC 250 V 30 x 10
6
switching operations 30 x 10
6
switching operations
Service life at lamp load 1.2 x 10
3
switching operations 1.2 x 10
3
switching operations
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +85 C -40 C ... +85 C
Dimensions (mm) W x H x L 17.5 x 55 x 90 17.5 x 55 x 90
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals DIN VDE 0160 and IEC 60255;
DIN VDE 0435 (corresp. parts)
DIN VDE 0160 and IEC 60255;
DIN VDE 0435 (corresp. parts)
300
200
100
50
40
30
20
10
0.1 0.2 0.5 1 2 5 10 20
Current (A)
resistive load
V
o
l
t
a
g
e
(
V
)
11
12
14
A2
A1
+
A2
A2
~
A1
~
A2
~
11
12
14
1
1
153
Relay with 2 changeover contacts (2 u)
Nominal input voltage V
N
24 V, 48 V, 110 V DC
Relay with 2 changeover contacts (2 u)
Nominal input voltage
V
N
24 V AC/DC, 115 V, 230 V AC
Other coil voltages contact factory
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay modules in DIN-rail mounted enclosure, for
DIN 35 rail
24 V DC 21 mA 789-312 1 24 V AC/DC 22 mA 789-512 1
48 V DC 13 mA 789-313 1 115 V AC 7.6 mA 789-515 1
110 V DC 6 mA 789-315 1 230 V AC 4.2 mA 789-516 1
Technical Data Accessories see page 162 Accessories see page 162
Contact material AgNi 90/10 AgNi 90/10
Input voltage range V
N
-15 % ... +10 % V
N
-15 % ... +10 %
Max. switching voltage 250 V AC/DC 250 V AC/DC
Max. make current (resistive) at a 10 % duty cycle 4 s / 15 A 4 s / 15 A
Max. continuous current 8 A 8 A
Max. Switching power (resistive) 2000 VA AC, DC see load limit curve 2000 VA AC, DC see load limit curve
Recommended minimum load > 100 mA / 12 V AC/DC > 100 mA / 12 V AC/DC
Operating power 400 mW 0.96 VA
Pull-in/drop-out/bounce time typ. 7 ms / 2 ms / 3 ms 7 ms / 2 ms / 3 ms
Nominal operating mode continuous duty continuous duty
Dielectric strength contact-coil (AC, 1 min) 5 kV 5 kV
Dielectric strength open contact 1 kV 1 kV
Dielectric strength contact-contact 2.5 kV 1.5 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 3 x 10
7
switching operations 5 x 10
6
switching operation
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +85 C -40 C ... +85 C
Dimensions (mm) W x H x L 17.5 x 55 x 90 17.5 x 55 x 90
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals DIN VDE 0160 and IEC 60255;
DIN VDE 0435 (corresp. parts)
DIN VDE 0160 and IEC 60255;
DIN VDE 0435 (corresp. parts)
300
200
100
50
40
30
20
10
Current (A)
2-pole
resistive load
2 contacts in serie
1 contact
V
o
l
t
a
g
e
(
V
)
0.1 0.2 0.5 1 2 5 10 20
A1
+
A2
A2
11
24
14
12
22
21
A2
~
A1
~
A2
~
11
24
14
12
22
21
1
154
Relay Modules in DIN-Rail Mounted Enclosure
Relay with 4 make contacts (4 a)
Nominal input voltage V
N
24 V DC
Relay with 4 make contacts (4 a)
Nominal input voltage V
N
12 V, 24 V AC/DC
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay modules in DIN-rail mounted enclosure, for
DIN 35 rail
24 V DC 12 mA 789-352 1 12 V AC/DC 21 mA 789-551 1
24 V AC/DC 12 mA 789-552 1
Technical Data Accessories see page 162 Accessories see page 162
Contact material AuAg10 over AgNi 15 AuAg10 over AgNi 15
Input voltage range V
N
-15 % ... +10 % V
N
-15 % ... +10 %
Max. switching voltage 250 V AC / 30 V DC 250 V AC / 30 V DC
Max. switching current 4 A AC / 3 A DC 4 A AC / 3 A DC
Max. Switching power (resistive) 1000 VA / 90 W, resistive see load limit curve 1000 VA / 90 W, resistive see load limit curve
Recommended minimum load > 100 A / 100 mV DC > 100 A / 100 mV DC
Pull-in/drop-out/bounce time typ. 15 ms / 10 ms / 1 ms 20 ms / 20 ms / 1 ms
Nominal operating mode continuous duty continuous duty
Max. switching frequency with load 6 min
-1
6 min
-1
Dielectric strength contact-coil (AC, 1 min) 1.5 kV 1.5 kV
Dielectric strength open contact 0.75 kV 0.75 kV
Dielectric strength contact-contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
230 V / 2.5 kV / 3 230 V / 2.5 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +85 C -40 C ... +85 C
Dimensions (mm) W x H x L 17.5 x 55 x 90 17.5 x 55 x 90
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals DIN VDE 0110 Part1 / 4.97 IEC 60 664-1;
DIN VDE 0435 (corresp. parts), EN 61 810
DIN VDE 0110 Part1 / 4.97 IEC 60 664-1;
DIN VDE 0435 (corresp. parts), EN 61 810
10
0.1 1 10
100
1000
C
o
n
t
a
c
t
v
o
l
t
a
g
e
(
V
)
Contact current (A)
DC resistive load AC resistive load
A1
+
A2
A2
14 24 34 44
13 23 33 43
14 24 34 44
13 23 33 43
A2
~
A1
~
A2
~
1
1
155
Relay with 2 break and
2 make contacts (2 ar)
Nominal input voltage V
N
24 V DC
Relay with 2 break and
2 make contacts ( 2 ar)
Nominal input voltage V
N
12 V, 24 V AC/DC
Note:Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay coils
and contacts!
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay modules in DIN-rail mounted enclosure, for
DIN 35 rail
24 V DC 12 mA 789-336 1 12 V AC/DC 21 mA 789-535 1
24 V AC/DC 12 mA 789-536 1
Technical Data Accessories see page 162 Accessories see page 162
Contact material AuAg10 over AgNi 15 AuAg10 over AgNi 15
Input voltage range V
N
-15 % ... +10 % V
N
-15 % ... +10 %
Max. switching voltage 250 V AC / 30 V DC 250 V AC / 30 V DC
Max. switching current 4 A AC / 3 A DC 4 A AC / 3 A DC
Max. Switching power (resistive) 1000 VA / 90 W, resistive see load limit curve 1000 VA / 90 W, resistive see load limit curve
Recommended minimum load > 100 A / 100 mV DC > 100 A / 100 mV DC
Pull-in/drop-out/bounce time typ. 15 ms / 10 ms / 1 ms 20 ms / 20 ms / 1 ms
Nominal operating mode continuous duty continuous duty
Max. switching frequency with load 6 min
-1
6 min
-1
Dielectric strength contact-coil (AC, 1 min) 1.5 kV 1.5 kV
Dielectric strength open contact 0.75 kV 0.75 kV
Dielectric strength contact-contact 1 kV 1 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
230 V / 2.5 kV / 3 230 V / 2.5 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +85 C -40 C ... +85 C
Dimensions (mm) W x H x L 17.5 x 55 x 90 17.5 x 55 x 90
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals DIN VDE 0110 Part1 / 4.97 IEC 60 664-1;
DIN VDE 0435 (corresp. parts), EN 61 810
DIN VDE 0110 Part1 / 4.97 IEC 60 664-1;
DIN VDE 0435 (corresp. parts), EN 61 810
10
0.1 1 10
100
1000
C
o
n
t
a
c
t
v
o
l
t
a
g
e
(
V
)
Contact current (A)
DC resistive load AC resistive load
14 24 12 22
13 23 11 21
A2
A1
+
A2
A1
~
A2
~
A2
~
14 24 12 22
13 23 11 21
1
156
Relay Modules in DIN-Rail Mount Enclosure
Relay with 1 changeover contact (1 u),
manual configuration,
electrical and mechanical activation indicator
Relay with 2 changeover contacts (2 u),
manual configuration,
electrical and mechanical activation indicator
Similiar to picture Similiar to picture
Note: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay coils
and contacts.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay module in DIN 35-rail mount enclosure 24 VDC 789-1341 24 VDC 789-1346
Technical Data Accessories see page 162 Accessories see page 162
Coil
Input voltage range U
N
-10% ... +10 % U
N
-10% ... +10 %
Contacts
Contact material AgNi AgNi
Max. continuous current 12 A 2 x 8 A
Max. make current (resistive) at a 10 % duty cycle 16 A 8 A
Max. switching voltage 250 VAC 250 VAC
Max. Switching power (resistive) 3000 VA AC 2 x 2000 VA AC
Pull-in/drop-out/bounce time typ. 15 ms / 8 ms / - 15 ms / 8 ms / -
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
General specifications:
Nominal voltage to EN 60664 250 V / 4 kV / 3 250 V / 4 kV / 3
Dielectric strength contact-coil 5 kV
eff
5 kV
eff
Surge capacity open contact 1 kV
eff
1 kV
eff
Dielectric strength contact-contact (AC, 1 min.) - 1.5 kV
eff
Ambient operating temperature (V
N
) -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 17.5 x 55 x 90 17.5 x 55 x 90
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Standards/Specifications EN 60664-1 EN 60664-1
(OT = On-time)
Switching voltage (V)
S
w
i
t
c
h
i
n
g
c
u
r
r
e
n
t
(
A
)
2 change over contacts
1 change over contact
11
12
14
A1
+
A2
A1
+
A2
11
24
14
12
22
21
1
1
157
Relay Modules in DIN-Rail Mount Enclosure
Relay with 1 changeover contact (1 u),
manual configuration,
electrical and mechanical activation indicator
Relay with 2 changeover contacts (2 u),
manual configuration,
electrical and mechanical activation indicator
Similiar to picture
Note: Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay coils
and contacts.
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay module in DIN 35-rail mount enclosure 230 789-1544 230 789-1549
Technical Data Accessories see page 162 Accessories see page 162
Coil
Input voltage range U
N
-10% ... +10 % U
N
-10% ... +10 %
Contacts
Contact material AgNi AgNi
Max. continuous current 12 A 2 x 8 A
Max. make current (resistive) at a 10 % duty cycle 16 A 8 A
Max. switching voltage 250 VAC 250 VAC
Max. Switching power (resistive) 3000 VA AC 2 x 2000 VA AC
Pull-in/drop-out/bounce time typ. 15 ms / 8 ms / - 15 ms / 8 ms / -
Mechanical life 5 x 10
6
switching operations 5 x 10
6
switching operations
General specifications:
Nominal voltage to EN 60664 250 V / 4 kV / 3 250 V / 4 kV / 3
Dielectric strength contact-coil 5 kV
eff
5 kV
eff
Surge capacity open contact 1 kV
eff
1 kV
eff
Dielectric strength contact-contact (AC, 1 min.) - 1.5 kV
eff
Ambient operating temperature (V
N
) -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) W x H x L 17.5 x 55 x 90 17.5 x 55 x 90
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Standards/Specifications EN 60664-1 EN 60664-1
(OT = On-time)
Switching voltage (V)
S
w
i
t
c
h
i
n
g
c
u
r
r
e
n
t
(
A
)
2 change over contacts
1 change over contact
11
12
14
A1
~
A2
~
11
24
14
12
22
21
A1
~
A2
~
1
158
Relay Modules in DIN-Rail Mounted Enclosure
Latching relay with 1 make contact (1 a)
Nominal input voltage V
N
24 V DC
Latching relay with 1 make contact (1 a)
Nominal input voltage V
N
230 V AC
Lamp load: max. load 1500 W
Fluorescent lamp, dual circuit:
max. load 20 x 58 W series compensated
Electronic ballasts: 10 x 58 W
Description V
N
I
N
Item No.
Pack.
Unit
V
N
I
N
Item No.
Pack.
Unit
Relay modules in DIN-rail mounted enclosure, for
DIN 35 rail
24 V DC 42 mA 789-571 1 230 V AC 10 mA 789-570 1
Technical Data Accessories see page 162 Accessories see page 162
Contact material AgCdO AgCdO
Input voltage range V
N
-15 % ... +10 % V
N
-15 % ... +10 %
Max. switching voltage 400 V AC 400 V AC
Min. switching current 0.1 A 0.1 A
Max. switching current 50 A (20 ms) 50 A (20 ms)
Max. continuous current 16 A 16 A
Max. Switching power (resistive) 4000 VA AC / 300 W DC 4000 VA AC / 300 W DC
Minimum switch-on time 40 ms 40 ms
Minimum break time 180 ms 180 ms
Coil control Impuls Impuls
Fuse protection circuit breaker max. 16 A B-charakteristic circuit breaker max. 16 A B-charakteristic
Nominal operating mode continuous duty continuous duty
Max. switching frequency with load 6 min
-1
6 min
-1
Max. switching frequency without load 4 s
-1
4 s
-1
Dielectric strength contact-coil (AC, 1 min) 4 kV 4 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Mechanical life 1 x 10
5
switching operations 1 x 10
5
switching operations
Mechanical life at max. load (resistance) 5 x 10
4
switching operations 5 x 10
4
switching operations
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Storage temperature -40 C ... +85 C -40 C ... +85 C
Dimensions (mm) W x H x L 17.5 x 55 x 90 17.5 x 55 x 90
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals DIN VDE 0160 and IEC 60255;
DIN VDE 0435 (corresp. parts); DIN VDE 0632
DIN VDE 0160 and IEC 60255;
DIN VDE 0435 (corresp. parts); DIN VDE 0632
A1
+
A2
13
14
A1
~
A2
~
13
14
1
1
159
Relay with 1 make contact (1a),
manual-0-automatic switch
Capability of different lamp loads:
(switching operations acc. to EN 60669)
Note:Inductive loads have to be attenuated by an
appropriate protective circuit in order to protect relay coils
and contacts!
Description V
N
Item No.
Pack.
Unit
Relay modules in DIN-rail mounted enclosure, for
DIN 35 rail
24 V DC 789-323 1
Technical Data Accessories see page 162
Contact material Ag-Legierung
Input voltage range V
N
-15 % ... +20 %
Current input at rated voltage (coil 20 C) 19 mA
Max. switching voltage 250 V AC
Max. make current 120 A at 230 V AC (50 ms)
Max. continuous current 16 A
Max. Switching power (resistive) 4000 VA AC, resistance see load limit curve
Recommended minimum load > 100 mA / 12 V AC/DC
Operating power 400 mW
Pull-in/drop-out/bounce time typ. 15 ms / 5 ms
Nominal operating mode continuous duty
Dielectric strength contact-coil 4
Surge capacity open contact 1
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Mechanical life 10 x 10
6
switching operations
Mechanical life at max. load (resistance) min. 100.000 switching operations
Mechanical life at max. lamp load see "Lamp loads" table
Ambient operating temperature -25 C ... +40 C
Storage temperature -40 C ... +70 C
Dimensions (mm) W x H x L 17,5 x 55 x 90
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
-SYSTEM,
MULTICONNECTION SYSTEM,
TOPJOB
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
Single-wire connection,
without LED
Mounting carrier for DIN 35 rail
Interface module, 8-pole,
for Siemens-SIMATIC
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
Single-wire connection,
with LED
Mounting carrier for DIN 35 rail
Description Width Item No.
Pack.
Unit
Width Item No.
Pack.
Unit
Interface module 44 289-680 1 44 289-681 1
Technical Data
Operating voltage 125 V AC/DC 24 V DC
Nominal current per signal wire 1 A 1 A
Max. total current (supply) 2 A 2 A
Connector contact phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni
Performance level 3 3
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
125 V / 0.8 kV / 2
Dimensions (mm) W x H x L incl.
mounting feet or mounting carrier
W x 48 x 85 W x 48 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
3-wire sensors,
without LED
Mounting carrier for DIN 35 rail
Interface module, 8-pole,
for Siemens-SIMATIC
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
3-wire sensors,
with LED
Mounting carrier for DIN 35 rail
Description Width Item No.
Pack.
Unit
Width Item No.
Pack.
Unit
Interface module 54 289-682 1 54 289-683 1
Technical Data
Operating voltage 125 V AC/DC 24 V DC
Nominal current per signal wire 1 A 1 A
Max. total current (supply) 2 A 2 A
Connector contact phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni
Performance level 3 3
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
125 V / 0.8 kV / 2
Dimensions (mm) W x H x L incl.
mounting feet or mounting carrier
W x 62 x 85 W x 62 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
Single-wire connection,
without LED
Mounting carrier for DIN 35 rail
Interface module, 32-pole,
for Siemens-SIMATIC
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
Single-wire connection,
with LED
Mounting carrier for DIN 35 rail
Description Width Item No.
Pack.
Unit
Width Item No.
Pack.
Unit
Interface module 112 289-684 1 112 289-685 1
Technical Data
Operating voltage 125 V AC/DC 24 V DC
Nominal current per signal wire 1 A 1 A
Max. total current (supply) 2 A / byte 2 A / byte
Connector contact phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni
Performance level 3 3
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
125 V / 0.8 kV / 2
Dimensions (mm) W x H x L incl.
mounting feet or mounting carrier
W x 48 x 85 W x 48 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
3-wire sensors,
without LED
Mounting carrier for DIN 35 rail
Interface module, 32-pole,
for Siemens-SIMATIC
S5-95 U to 155 U,
S7-300/ET 200 M und S7-400
3-wire sensors,
with LED
Mounting carrier for DIN 35 rail
Description Width Item No.
Pack.
Unit
Width Item No.
Pack.
Unit
Interface module 176 289-686 1 176 289-687 1
Technical Data
Operating voltage 125 V AC/DC 24 V DC
Nominal current per signal wire 1 A 1 A
Max. total current (supply) 2 A / byte 2 A / byte
Connector contact phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni phosphor-bronze, 0.38 m Au selectively over 1.3 m Ni
Performance level 3 3
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
125 V / 0.8 kV / 2
Dimensions (mm) W x H x L incl.
mounting feet or mounting carrier
W x 62 x 85 W x 62 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 12 0.08 mm ... 2.5 mm / AWG 28 ... 12
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Application examples see page 197 see page 197
Accessories Spare relay 857-152 Spare relay 857-152
1 16
Rel. 1 Rel. 16
18 20 17 19
F
=
1
A
+F +
11 14 12 161 164 162
1 16
Rel. 1 Rel. 16
18 20 17 19
F
=
1
A
O
N
O
F
F
A
U
T
O
+F +
11 14 12 161 164 162
O
N
O
F
F
A
U
T
O
2
199
2
Relay output module with miniature switching
relay for 16 channels, 1 changeover contact
each (1 u) with integrated status indication,
20-pole ribbon cable connector to DIN 41651
Relay output module with miniature switching
relay for 16 channels, 1 changeover contact
each (1 u) with integrated status indication
and output fuse,
20-pole ribbon cable connector to DIN 41651
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Switching relay module,
for DIN 35 rail
704-5004 1 704-5034 1
Switching relay module without miniature switching
relay, for DIN 35 rail
704-5014 1
Technical Data
Contact material AgNi 90/10 AgNi 90/10
Contact type 1 changeover contact 1 changeover contact
Operating voltage 24 V DC ( 10 %) 24 V DC ( 10 %)
Max. switching voltage 250 V AC / 48 V DC 250 V AC / 48 V DC
Max. continuous current 5 A 5 A
Inrush current 2 s 16 A 2 s 16 A
Max. switching power (resistive) 1250 VA / 50 W 1250 VA / 50 W
Status indication LED green : Channel
LED yellow : Power supply
LED green : Channel
LED yellow : Power supply
Mechanical life 30 x 10
6
switching operations 30 x 10
6
switching operations
Dielectric strength contact-coil (AC, 1 min) 3 kV 4 kV
Dielectric strength contact-contact 1 kV 1 kV
Fuse Supply: 1 A
Relay output:
Supply: 1 A
Relay output: 5 A
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) L x W x H incl. mounting carrier and relay 180 x 50 x 105 247 x 55 x 105
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection Input: 20-pole ribbon cable connector to DIN 41651
Output: CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 12 0.08 mm ... 2.5 mm / AWG 28 ... 12
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Application examples see page 197 see page 197
Accessories Spare relay 788-154 Spare relay 788-154
1 16
Rel. 1 Rel. 16
18 20 17 19
F
=
1
A
+F +
11 14 12 161 164 162
1 16
5
A
5
A
Rel. 1 Rel. 16
18 20 17 19
F
=
1
A
+F +
11 14 12 161 164 162
2
200
Interface Modules for System Wiring
Relay output module with miniature switching
relay for 16 channels, 1 make contact each
(1 a) with integrated status indication,
disconnect terminal block and output fuse,
20-pole ribbon cable connector to DIN 41651
Relay output module with miniature switching
relay for 16 channels, 1 make contact each
(1 a) with integrated status indication, double
disconnect terminal block and output fuse,
20-pole ribbon cable connector to DIN 41651
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Switching relay module,
for DIN 35 rail
704-5054 1 704-5074 1
Technical Data
Contact material AgNi 90/10 AgNi 90/10
Contact type 1 make contact 1 make contact
Operating voltage 24 V DC ( 10 %) 24 V DC ( 10 %)
Max. switching voltage 250 V AC / 48 V DC 250 V AC / 48 V DC
Max. continuous current 2 A 5 A
Max. switching power (resistive) 500 VA / 50 W 1250 VA / 50 W
Status indication LED green : Channel
LED yellow : Power supply
LED green : Channel
LED yellow : Power supply
Mechanical life 30 x 10
6
switching operations 30 x 10
6
switching operations
Dielectric strength contact-coil (AC, 1 min) 4 kV 4 kV
Dielectric strength contact-contact 1 kV 1 kV
Fuse Supply: 1 A
Relay output: 2 A
Supply: 1 A
Relay output: 5 A
Ambient operating temperature -25 C ... +50 C -25 C ... +50 C
Storage temperature -40 C ... +70 C -40 C ... +70 C
Dimensions (mm) L x W x H incl. mounting carrier and relay 240 x 55 x 105 240 x 55 x 105
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection Input: 20-pole ribbon cable connector to DIN 41651
Output: CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 12 0.08 mm ... 2.5 mm / AWG 28 ... 12
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Application examples see page 197 see page 197
Accessories Spare relay 788-154 Spare relay 788-154
C1 C1 C2 C2 1F 1K 8F 8K
2
A
2
A
Rel. 1 Rel. 8
F
=
1
A
+F +
2
A
2
A
Rel. 9 Rel. 16
C3 C3 C4 C4 9F 9K 16F 16K
1 8
18 20 17 19 9 16
5
A
5
A
1
11 14
16
Rel. 1 Rel. 16
161 164
18 20 17 19
F
=
1
A
+F +
2
201
2
Relay output module with miniature switching
relay for 16 channels, 2 changeover contacts
each (2 u) with integrated status indication,
20-pole ribbon cable connector to DIN 41651
Description Item No.
Pack.
Unit
Switching relay module,
for DIN 35 rail
704-5064 1
Technical Data
Contact material AgNi 90/10
Contact type 2 changeover contact
Operating voltage 24 V DC ( 10 %)
Max. switching voltage 250 V AC / 48 V DC
Max. continuous current 5 A
Inrush current 2 s 8 A
Max. switching power (resistive) 1000 VA / 50 W
Status indication LED green : Channel
LED yellow : Power supply
Mechanical life 30 x 10
6
switching operations
Dielectric strength contact-coil (AC, 1 min) 4 kV
Dielectric strength contact-contact 1 kV
Fuse Supply: 1 A
Relay output:
Ambient operating temperature -25 C ... +50 C
Storage temperature -40 C ... +70 C
Dimensions (mm) L x W x H incl. mounting carrier and relay 247 x 50 x 105
Height from upper-edge of DIN 35 rail
Wire connection Input: 20-pole ribbon cable connector to DIN 41651
Output: CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 12 0.08 mm ... 2.5 mm / AWG 28 ... 12
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Application examples see page 197 see page 197
Accessories Spare relay 857-152 Spare relay 857-152
1 8
Rel. 1 Rel. 8
10 9
F
=
1
A
+F +
11 14 12 81 84 82
1 8
Rel. 1 Rel. 8
10 9
F
=
1
A
O
N
O
F
F
A
U
T
O
+F +
11 14 12 81 84 82
O
N
O
F
F
A
U
T
O
2
203
2
WAGO Ribbon Cables
WAGO ribbon cables provide fast and easy connection of WAGO I/O modules
equipped with a ribbon cable connector (750-1400, -1402, -1500, -1501, 1502) to
appropriate interface or relay modules (16-channel) featuring a 20-pole female
connector. The cables are available in 1-, 2- and 3-meter lengths; each has one 20-pole
female connector at both ends.
WAGO ribbon cables provide fast and easy connection of WAGO I/O modules
equipped with a ribbon cable connector (750-1400, -1402, -1500, -1501, 1502) to
appropriate interface or relay modules featuring a 10-pole female connector. For
example, this cable connects 2 relay modules (8-channel) to a WAGO I/O module. The
cables are available in 1- and 2-meter lengths; each has one 20-pole and two 10-pole
female connectors on the ends.
Description Item No.
Pack.
Unit
Description Item No.
Pack.
Unit
WAGO ribbon cable 20/20, lenght 1 m 706-3057/300-100 1 WAGO ribbon cable 20/2x10, lenght 1 m 706-7753/302-100 1
WAGO ribbon cable 20/20, lenght 2 m 706-3057/300-200 1 WAGO ribbon cable 20/2x10, lenght 2 m 706-7753/302-200 1
WAGO ribbon cable 20/20, lenght 3 m 706-3057/300-300 1
Technical Data Technical Data
Connections 2 x 20-pole female connector
acc. to DIN 41651
Connections 1 x 20-pole / 2 x 10-pole female
connector
Wire cross-section 0.14 mm
2
LiYY Wire cross-section 0.14 mm
2
LiYY
Color coding acc. to DIN VDE 47100 Color coding acc. to DIN VDE 47100
Current per channel max. 1 A Current per channel max. 1 A
Operating temperature -25 C ... +70 C Operating temperature -25 C ... +70 C
Degree of protection IP20 Degree of protection IP20
Length 1 m (706-3057/300-100)
2 m (706-3057/300-200)
3 m (706-3057/300-300)
Length 1 m (706-7753/302-100)
2 m (706-7753/302-200)
2
204
Interface Modules
RJ-45 interface module
with shield clamping unit
for WAGO shield (screen) clamping saddle
Mounting carrier for DIN 35 rail
RJ-45 interface module
cross-over connection
Mounting carrier for DIN 35 rail
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Interface module 289-178 1 289-177 1
Technical Data
Connecting cable min. CAT5 min. CAT5
Max. transmission length 100 m 100 m
Connector RJ-45 shielded RJ-45 shielded
Min. mating cycles 1000 1000
Current load d 2.1 A d 2.1 A
Voltage load 35 V AC / 50 V DC 35 V AC / 50 V DC
Insulation resistance > 500 M > 500 M
Dielectric strength contact-contact 1 kV eff. 1 kV eff.
Contact resistance typ. 40 m typ. < 40 m
WAGO shield (screen) clamping saddle 11 mm wide; cable diameter up to 8 mm
Ambient operating temperature -20 C ... +85 C -20 C ... +85 C
Dimensions (mm) W x H x L incl.
mounting feet or mounting carrier
30 x 67 x 85 30 x 51 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
+
+
+
+
+
+
+
+
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
<__________ 85 _________>
<
_
_
_
_
_
_
5
6
_
_
_
_
_
_
>
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
<_____________105 ______________>
+
+
+
+
+
+
+
+
+
+
<
_
_
_
_
_
_
5
6
_
_
_
_
_
_
>
2
209
2
Connection module
for 8 actuators
Connection module
for 8 actuators with ground (earth) contact
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Connection module 289-667 1 289-671 1
Technical Data
Operating voltage 125 V AC/DC 125 V AC/DC
Max. current per connection 1 A 1 A
Max. total current 8 A 8 A
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
125 V / 1.5 kV / 2 125 V / 1.5 kV / 2
Dimensions (mm) W x H x L incl.
mounting feet or mounting carrier
56 x 34 x 85 56 x 34 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
<_________ 85 _________>
<
_
_
_
_
_
_
5
6
_
_
_
_
_
_
>
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
<__________ 85 _________>
<
_
_
_
_
_
_
5
6
_
_
_
_
_
_
>
2
210
Rail-Mounted Modules - Diode Gates
Open diode gate
with 8 diodes 1 N 4007
can be connected individually
Open diode gate
with 8 diodes P 600 B
can be connected individually
* Max. admissible current acc. to the manufacters data
sheet. With all diodes loaded, the continuous current must
be reduced.
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Open diode gate 289-101 1 289-103 1
Technical Data
Operating voltage 250 V AC/DC 100 V AC/DC
Peak reverse voltage 1000 V 100 V
Rectified current for each diode * 1 A 6 A
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +30 C
Dimensions (mm) L x W x H incl. mounting carrier and
universal mounting feet
47 x 31.5 x 65.5 47 x 31.5 x 65.5
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
+
1 2 3 4 5 6 7
8 9 10 11 12 13 14
+
+
1 2 3 4 5 6 7
8 9 10 11 12 13 14
2
213
2
Lamp test circuit module
with 20 diodes for testing 10 lamps with
Mounting feet for DIN 35 rail
LED gate module
with 16 LEDs, common anode or cathode
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Gate module 289-151 1 289-202 1
289-201 1
Technical Data
Operating voltage 250 V AC/DC 24 V DC
Operating voltage range 0 V ... 250 V AC/DC 20 V ... 26 V DC
Power consumption at V
N
5.6 mA each LED
Peak reverse voltage 1600 V
Rectified current for each diode, resistive 1 A
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Dimensions (mm) W x H x L incl.
mounting feet or mounting carrier
69 x 21 x 50 47 x 31.5 x 65.5
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
+
8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9
+
+
2
214
Rail-Mounted Modules - Resistor Gates
Resistor gate
with 1 end commoned,
8 resistors 2 k 2; 1 W
Open resistor gate
with 8 resistors 2 k 7; 0.6 W
individual connection possible
other resistors contact factory
* Max. admissible power dissipation of a single resistor.
With all resistors loaded, the max. admissible power
dissipation must be reduced.
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Resistor gate 289-113 1 289-114 1
Technical Data
Operating voltage 40 V AC/DC 40 V AC/DC
Resistor type DIN 0414 DIN 0207
Temperature coefficient 50 ppm 50 ppm
Tolerance 1% 1%
Power dissipation * 1 W 0.6 W
Ambient operating temperature -25 C ... +40 C -25 C ... +40 C
Dimensions (mm) L x W x H incl. mounting carrier and
universal mounting feet
47 x 31.5 x 65.5 47 x 31.5 x 65.5
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
Transducers
Isolation amplifier, with zero/span adjustment
OUT IN
POWER
5
6
1
2
3
4
7
8
OUT+
GND 2
Us+
GND 3
IN+
GND 1
Us+
GND 3
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
Conguration via:
DIP Switches
Short description:
The configurable 857-400 Isolation Amplifier is used to convert, amplify, filter
and electrically isolate analog standard signals.
Characteristics:
Zero/span adjustment across the entire measuring range
Calibrated scale switching
Switchable max. operating frequency
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 36.8 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
219
3
= ON 857-400 DIP Switch Adjustability
Dip Switch S1 (2-fold) Dip Switch S2 (6-fold)
Input Signal Output Signal
Max. Operating
Frequency
1 2 1 2 3 4 5 6
0 ... 20 mA 0 ... 20 mA 100 Hz
4 ... 20 mA > 5 kHz
0 ... 10 V
2 ... 10 V
0 ... 5 V
1 ... 5 V
4 ... 20 mA 0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 V
0 ... 5 V
1 ... 5 V
0 ... 10 V 0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 V
0 ... 5 V
1 ... 5 V
2 ... 10 V 0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 V
0 ... 5 V
1 ... 5 V
0 ... 5 V 0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 V
0 ... 5 V
1 ... 5 V
1 ... 5 V 0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 V
0 ... 5 V
1 ... 5 V
Default Settings
Input 0 ... 20 mA
Output 0 ... 20 mA
Max. Operating Frequency 100 Hz
857-401
3
220
JUMPFLEX
Transducers
Isolation amplifier, configurable with digital output
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT+
GND 2
OUT
U,I
Us+
GND 3
POWER
IN+
GND 1
DO
GND 3
5
6
IN
U,I
1
2
DO
3
4
7
8
Conguration via:
DIP Switches Conguration
Software
Short description:
The software-configurable 857-401 Isolation Amplifier converts standard signals and
amplifies, filters and electrically isolates analog standard signals.
Characteristics:
FDT/DTM configuration interface
Digital switching output
Calibrated scale switching
Analog, unipolar and bipolar, standard signals at input
Clipping capability allows analog standard signal limitation to upper range values.
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 42 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I Div2 ABCD T4
Shipbuilding g (pending)
Accessories see pages 268 ... 271
( * Additional setting options are possible via FDT-/DTM configuration tool.)
3
221
3
= ON 857-401
Input Signal
Start Value
DIP S1
1 2 3 4 5 6 7 V mA 2 3 4 5 6 7 V mA
Voltage 0 0 5.5 11
Current -10 -20 6 12
-9.5 -19 6.5 13
-9 -18 7 14
-8.5 -17 7.5 15
-8 -16 8 16
-7.5 -15 8.5 17
-7 -14 9 18
-6.5 -13 9.5 19
-6 -12 10 20
-5.5 -11 10.5
-5 -10 11
-4.5 -9 11.5
-4 -8 12
-3.5 -7 13
-3 -6 14
-2.5 -5 15
-2 -4 16
-1.5 -3 17
-1 -2 18
-0.5 -1 19
0 0 20
0.5 1 21
1 2 22
1.5 3 23
2 4 24
2.5 5 25
3 6 26
3.5 7 27
4 8 28
4.5 9 29
5 10 30
Input Signal
End Value
DIP S1 DIP S2 DIP S1 DIP S2
8 9 10 1 2 3 V mA 8 9 10 1 2 3 V mA
10 20 5.5 11
-10 -20 6 12
-9.5 -19 6.5 13
-9 -18 7 14
-8.5 -17 7.5 15
-8 -16 8 16
-7.5 -15 8.5 17
-7 -14 9 18
-6.5 -13 9.5 19
-6 -12 10 20
-5.5 -11 10.5
-5 -10 11
-4.5 -9 11.5
-4 -8 12
-3.5 -7 13
-3 -6 14
-2.5 -5 15
-2 -4 16
-1.5 -3 17
-1 -2 18
-0.5 -1 19
0 0 20
0.5 1 21
1 2 22
1.5 3 23
2 4 24
2.5 5 25
3 6 26
3.5 7 27
4 8 28
4.5 9 29
5 10 30
DIP Switch S2
Output Signal
Measuring Range Underow Measuring Range Overow
Digital Output DO
Signaling
4 5 6 7 8 9 10
0 20 mA
Lower limit of output range
- 5 % *
Upper limit of output range
+ 2,5 % *
DO not active
4 20 mA
0 10 mA
Lower limit of output range
Upper limit of output range
+ 2,5 %
GND U
N
(switching)
2 10 mA
0 10 V
Lower limit of output range Upper limit of output range U
N
GND
(switching)
2 10 V
0 5 V
Lower limit of output range Upper limit of output range
1 5 V
*acc. to NAMUR NE 43
Default Settings
All DIP switches are in OFF position for delivery.
This is the position used to parameterize the device via FDT/DTB conguration software.
Input
Input signal Voltage
Start value 0 V
End value 10 V
Output
Output signal Current
Start value 0 mA
End value 20 mA
Measuring range underow 0 mA
Measuring range overow 20.5 mA
Digital output DO not active
DIP Switch Adjustability
857-402
3
222
JUMPFLEX
Transducers
Universal Isolation Amplifier
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
U; I
IN
U; I
POWER
5
6
1
2
3
4
7
8
OUT+
OUT-
Us+
GND 3
U+
I+
I+
I-/U-
Conguration via:
DIP Switches Push/Slide Switch
Short description:
The universal 857-402 Isolation Amplifier converts unipolar and bipolar standard signals
and amplifies, filters and electrically isolates analog standard signals.
Characteristics:
Overload protection of current input using reversible fuse
Zero/span adjustment across the entire measuring range (slide switch)
Calibrated scale switching for all 456 signals
Standard analog unipolar and bipolar signals, input/output
Switchable max. operating frequency
Clipping capability allows analog standard signal limitation to upper range values.
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 54.3 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
223
3
= ON 857--402 DIP Switch Adjustability
DIP Switch S2
Output Signal Ranges Reserve Clipping Rocker Switch Lock
1 2 3 4 5 6 7 8
Default setting*
inactive
(analog response)
switched o
0 10 V
active
(limiting response)
switched on
10 V
2 10 V
0 5 V
5 V
1 5 V
0 20 mA
20 mA
4 20 mA
0 10 mA
10 mA
2 10 mA
DIP Switch S1
Input Signal Ranges Zero/Span Adjustment
Max. Operating
Frequency
1 2 3 4 5 6 7 8
Default setting* Inactive < 100 Hz
0 60 mV Active 5 kHz
60 mV
0 100 mV
100 mV
0 150 mV
150 mV
0 300 mV
300 mV
0 500 mV
500 mV
0 1 V
1 V
0 5 V
5 V
0 10 V
10 V
0 ... 50 V
50 V
0 100 V
100 V
0 200 V
200 V
DIP Switch S1
Input Signal Ranges
1 2 3 4 5 6
0 0.3 mA
0.3 mA
0 1 mA
1 mA
0 5 mA
5mA
0 10 mA
10 mA
0 20 mA
20 mA
0 50 mA
50 mA
0 100 mA
100 mA
1 5 V
2 10 V
2 10 mA
4 20 mA
*Default setting
Input 10 V
Output 10 V
Max. operating frequency > 5 kHz
* The input and output range DIP switches must be readjusted when changing the default setting.
More information on measurement range setting is available in 857-402 instruction leaet.
857-409
3
224
JUMPFLEX
Transducers
Bipolar isolation amplifier
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
IN
POWER
5
6
1
2
3
4
7
8
OUT+
OUT-
Us+
GND
U+
U
I+
I
U; I
U; I
Conguration via:
DIP Switches
Short description:
The 857-409 Bipolar Isolation Amplifier converts unipolar and bipolar standard signals
and amplifies, filters and electrically isolates analog standard signals.
Characteristics:
Overload protection of current input using reversible fuse
Zero/span adjustment across the entire measuring range
Calibrated scale switching
Standard analog unipolar and bipolar signals, input/output
Switchable max. operating frequency
Clipping capability allows analog standard signal limitation to upper range values.
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 42 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
225
3
= ON 857-409 DIP Switch Adjustability
Dip Switch S1 (4-fold) Dip Switch S2 (6-fold)
Input Signal Output Signal
Max. Operating
Frequency
Code IN 1 2 3 4 Code OUT 1 2 3 4 5 6
a 20 mA A 20 mA 100 Hz
b 10 mA B 10 mA > 5 kHz
c 10 V C 10 V
d 5 V D 5 V
e 0 20 mA E 0 20 mA
f 4 20 mA F 4 20 mA
g 0 10 mA G 0 10 mA
h 2 10 mA H 2 10 mA
j 0 10 V J 0 10 V
k 2 10 V K 2 10 V
l 0 5 V L 0 5 V
m 1 5 V M 1 5 V
Default Settings
Input 10 V
Output 10 V
Max. Operating Frequency > 5 kHz
857-411, 857-412, 857-413, 857-414, 857-415, 857-416
3
226
JUMPFLEX
Transducers
Isolation amplifiers, fixed setting for voltage or current signals
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT IN
POWER
5
6
1
2
3
4
7
8
OUT+
GND 2
Us+
GND 3
IN+
GND 1
Us+
GND 3
Short description:
The pre-configured isolation amplifiers convert, amplify, filter and electrically
isolate standard analog signals.
Characteristics:
Input/Output: current/voltage signal
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Input signal Output signal Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 49.2 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
3
227
3
857-420
3
228
JUMPFLEX
Transducers
Repeater power supply, configurable with current and voltage output
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
IN
POWER
5
6
1
2
3
4
7
8
OUT+
GND 2
Us+
GND 3
USensor+
IN
GND 1
GND 1
Conguration via:
DIP Switches
Short description:
The 857-420 Repeater Power Supply links 2- or 3-wire transmitters located in
the field. It provides the power required and transmits the analog signals in an
electrically isolated way.
Characteristics:
Power supply to SMART transmitters
Calibrated scale switching
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 46.7 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
229
3
= ON 857-420 DIP Switch Adjustability
Default Settings
Input 0 20 mA
Output 0 20 mA
DIP 6 n.c.
Dip Switch S1 (6-fold)
Input Signal Output Signal
1 2 3 4 5 6
n.c. 0 20 mA 0 20 mA
n.c. 0 20 mA 4 20 mA
n.c. 0 20 mA 0 10 V
n.c. 0 20 mA 2 10 V
n.c. 0 20 mA 0 5 V
n.c. 0 20 mA 1 5 V
n.c. 4 20 mA 0 20 mA
n.c. 4 20 mA 4 20 mA
n.c. 4 20 mA 0 10 V
n.c. 4 20 mA 2 10 V
n.c. 4 20 mA 0 5 V
n.c. 4 20 mA 1 5 V
+
2
3
2
1
3
2
1
3
+
1
2
5
6
+
8
7 +
= =
=
857-420
IN OUT
POWER
24 V DC
3-wire
2-wire
Transmitter
active
Transmitter
passive
Cong
24 V DC
U/I
OUT
+Us
GND
+IN
+Us
GND
Connection assignment
857-421
3
230
JUMPFLEX
Transducers
Repeater power supply, HART
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
IN
POWER
5
6
1
2
3
4
7
8
OUT +
GND 2
Us+
GND 3
USensor+
IN
GND 1
GND 1
Short description:
The 857-421 HART Repeater Power Supply links SMART transmitters located
in the field. It provides the power required and transmits the analog signals in
an electrically isolated way.
Characteristics:
HART communication
Power supply to SMART transmitters
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 47.8 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
231
3
20
4
mA
t
857-421 Simultaneous transmission of analog and digital signals
analog signal
HART - signal (digital)
857-423
3
232
JUMPFLEX
Transducers
Signal splitter with 2 configurable current outputs
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT 1 IN
POWER
5
6
1
2
3
4
7
8
OUT 1+
GND 2
Us+
GND 3
IN+
GND 1
OUT 2+
GND 4
OUT 2
Conguration via:
DIP Switches
Short description:
The 857-423 Signal Splitter converts standard signals and amplifies, filters and
electrically isolates analog standard signals.
Characteristics:
Two configurable current outputs
Calibrated scale switching
Switchable max. operating frequency
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 40.6 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
233
3
= ON 857-423 DIP Switch Adjustability
Default Settings
Input 0 20 mA
Output 1 0 20 mA
Output 2 0 20 mA
Max. Operating Frequency > 1 kHz
Dip Switch S1 (6-fold)
Input Signal
Max. Operating
Frequency
Output Signal 1 Output Signal 2
Code IN 1 2 3 4 Code OUT 5 Code OUT 6
e 0 20 mA > 1 kHz E 1 0 20 mA E 2 0 20 mA
f 4 20 mA 100 Hz F 1 4 20 mA F 2 4 20 mA
j 0 10 V
k 2 10 V
l 0 5 V
m 1 5 V
857-450
3
234
JUMPFLEX
Transducers
Loop-Powered Isolation Amplifier
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
4-20 mA
IN
U, I
N.C.
5
6
1
2
3
4
7
8
Us+
OUT 1
N.C.
N.C.
U+
U --
I+
I --
Conguration via:
DIP Switches
Short description:
The 857-450 Loop-Powered Isolation Amplifier converts analog, unipolar and bipolar,
standard signals. It is also designed to amplify, filter and electrically isolate standard
analog signals.
Characteristics:
No additional supply voltage required
Zero/span adjustment
Analog, unipolar and bipolar, standard signals at input
Calibrated scale switching
Switchable max. operating frequency
Safe 2-way isolation with 2.5 kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 12
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 5 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
235
3
_
+
_
+
4 ... 20 mA
4 ... 20 mA
8 ... 30 V
8 ... 30 V
= ON 857-450 DIP Switch Adjustability
DIP switch (6 positions)
Input Signal Output Signal
Max. Operating
Frequency
1 2 3 4 5 6
4 ... 20 mA
C
u
r
r
e
n
t
4 ... 20 mA
100 Hz
0 ... 20 mA 30 Hz
20 mA
2 10 mA
0 ... 10 mA
10 mA
0 ... 5 mA
5 mA
0 ... 20 V
V
o
l
t
a
g
e
20 V
2 ... 10 V
0 ... 10 V
10 V
1 ... 5 V
0 ... 5 V
5 V
0 ... 2 V
2 V
0 ... 1 V
1 V
Default setting
Input 4 ... 20 mA
Output 4 ... 20 mA
Max. operating frequency 100 Hz
Wiring Material
e.g. 0 ... 10 V
e.g. 0 ... 10 mA
e.g. 787-1002
PLC
Input card, passive
R
Load impedance
PLC
Input card, active
R
Load impedance
230 V AC
857-451
3
236
JUMPFLEX
Transducers
Passive isolator, 1 channel, 2 channels
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT IN
5
6
1
2
3
4
7
8
OUT+
GND 2
N.C.
N.C.
IN+
GND 1
N.C.
N.C.
Short description:
The 1- and 2-channel passive isolators filter and electrically isolate 0(4) - 20mA
analog standard signals.
Characteristics:
No additional supply voltage required
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 33.8 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
857-452
3
237
3
JUMPFLEX
Transducers
Passive isolator, 1 channel, 2 channels
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT 1 IN 1
5
6
1
2
3
4
7
8
OUT 1+
GND 2
OUT 2+
GND 4
IN 1+
GND 1
IN 2+
GND 3
OUT 2 IN 2
Short description:
The 1- and 2-channel passive isolators filter and electrically isolate 0(4) - 20mA
analog standard signals.
Characteristics:
No additional supply voltage required
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 37.8 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
857-800
3
238
JUMPFLEX
Transducers
Temperature transducer for Pt 00, Pt200, Pt500 and Pt1000 as well as resistors 0 ... 1 k; 0 ... 4.5 k
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
IN
5
6
1
2
3
4
7
8
OUT+
GND 1
Us+
GND 2
POWER
Conguration via:
DIP Switches
Short description:
The 857-800 Temperature Transducer records Pt100, Pt200, Pt500 and Pt1000 sensors,
as well as resistors up to 4.5 kOhm, converting the temperature signal into a standard
analog signal on the output side.
Characteristics:
For Pt100, Pt200, Pt500 and Pt1000 sensors, as well as resistors up to 4.5 kOhm
2-, 3-, and 4-wire connection technology
Calibrated scale switching
Sensor's wire break/short circuit
Measuring range underflow/overflow
Clipping capability allows analog standard signal limitation to upper range values
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 42 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
3
239
3
= ON 857-800 DIP Switch Adjustability
DIP Switch S2
Start temperature End temperature
1 2 3 4 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F
75 167 210 410 475 887
-200 -328 0 32 80 176 220 428 500 932
-175 -283 5 41 85 185 230 446 525 997
-150 -238 10 50 90 194 240 464 550 1022
-125 -193 15 59 95 203 250 482 575 1067
-100 -148 20 68 100 212 260 500 600 1022
-90 -130 25 77 110 230 270 518 625 1112
-80 -112 30 86 120 248 280 536 650 1202
-70 -94 35 95 130 266 290 554 675 1247
-60 -76 40 104 140 284 300 572 700 1292
-50 -58 45 113 150 302 325 617 725 1337
-40 -40 50 122 160 320 350 662 750 1382
-30 -22 55 131 170 338 375 707 775 1427
-20 -4 60 140 180 356 400 752 800 1472
-10 14 65 149 190 374 425 797 825 1517
0 32 70 158 200 392 450 842 850 1562
The minimum distance from the start temperature to the end temperature may not fall short of 50K degrees on the Celsius (C) scale or 122K degrees on the Fahrenheit (F) scale.
DIP Switch S1
Wire connection Sensor type Output signal
Measuring range
underow
Measuring range
overow
Wire break Short circuit
1 2 3 4 5 6 7 8 9 10
2-wire Pt100 0 20 mA
Lower limit of output range
- 5 % *
Upper limit of output range
+ 2,5 % *
Upper limit of output range
+ 5 % *
Lower limit of output range
- 12,5 % *
3-wire Pt200 4 20 mA
4-wire Pt500 0 10 mA
Lower limit of output range
Upper limit of output range
+ 2,5 %
Upper limit of output range
+ 5 %
Lower limit of output range
Pt1000 2 10 mA
1 k 0 10 V
Lower limit of output range Upper limit of output range
Upper limit of output range
+ 5 %
Upper limit of output range
+ 5 %
4.5 k 2 10 V
0 5 V
Lower limit of output range Upper limit of output range Lower limit of output range Lower limit of output range
1 5 V
* acc. to NAMUR NE 43
Default Settings
All DIP switches are in OFF position for delivery.
Sensor connection 2-wire
Sensor type Pt 100
Start temperature 0 C
End temperature 100 C
Output signal 0 20 mA
Measuring range underow 0 mA
Measuring range overow 20.5 mA
Wire break 21 mA
Short circuit 0 mA
857-801
3
240
JUMPFLEX
Transducers
Temperature transducer for Pt100, Pt200, Pt500 and Pt1000 * as well as resistors 0 ... 1 k; 0 ... 4.5 k
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
IN
5
6
1
2
3
4
7
8
OUT+
GND 1
Us+
GND 2
POWER
Conguration via:
DIP Switches Conguration
Software
Short description:
The 857-801 Temperature Transducer records Pt100, Pt200, Pt500 and Pt1000 sensors, as well
as resistors up to 4.5 kOhm, converting the temperature signal into a standard analog signal on
the output side..
Characteristics::
FDT/DTM configuration interface
For Pt100, Pt200, Pt500 and Pt1000 sensors, as well as resistors up to 4.5 kOhm
2-, 3-, and 4-wire connection technology
Calibrated scale switching
Sensor's wire break/short circuit
Measuring range underflow/overflow
Clipping capability allows analog standard signal limitation to upper range values.
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 49.2 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
( * Setting of other types of sensors as well as output signal inversion using the
configuration software)
3
241
3
= ON 857-801
DIP Switch S2
Start temperature End temperature
1 2 3 4 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F
75 167 210 410 475 887
-200 -328 0 32 80 176 220 428 500 932
-175 -283 5 41 85 185 230 446 525 997
-150 -238 10 50 90 194 240 464 550 1022
-125 -193 15 59 95 203 250 482 575 1067
-100 -148 20 68 100 212 260 500 600 1022
-90 -130 25 77 110 230 270 518 625 1112
-80 -112 30 86 120 248 280 536 650 1202
-70 -94 35 95 130 266 290 554 675 1247
-60 -76 40 104 140 284 300 572 700 1292
-50 -58 45 113 150 302 325 617 725 1337
-40 -40 50 122 160 320 350 662 750 1382
-30 -22 55 131 170 338 375 707 775 1427
-20 -4 60 140 180 356 400 752 800 1472
-10 14 65 149 190 374 425 797 825 1517
0 32 70 158 200 392 450 842 850 1562
The minimum distance from the start temperature to the end temperature may not fall short of 50K degrees on the Celsius (C) scale or 122K degrees on the Fahrenheit (F) scale.
Default Settings
All DIP switches are in OFF position for delivery.
This is the position used to parameterize the device via FDT/DTB conguration software.
Sensor connection 2-wire
Sensor type Pt 100
Start temperature 0 C
End temperature 100 C
Output signal 0 20 mA
Measuring range underow 0 mA
Measuring range overow 20.5 mA
Wire break 21 mA
Short circuit 0 mA
DIP Switch Adjustability
DIP Switch S1
Wire connection Sensor type Output signal
Measuring range
underow
Measuring range
overow
Wire break Short circuit
1 2 3 4 5 6 7 8 9 10
2-wire Pt100 0 20 mA
Lower limit of output range
- 5 % *
Upper limit of output range
+ 2,5 % *
Upper limit of output range
+ 5 % *
Lower limit of output range
- 12,5 % *
3-wire Pt200 4 20 mA
4-wire Pt500 0 10 mA
Lower limit of output range
Upper limit of output range
+ 2,5 %
Upper limit of output range
+ 5 %
Lower limit of output range
Pt1000 2 10 mA
1 k 0 10 V
Lower limit of output range Upper limit of output range
Upper limit of output range
+ 5 %
Upper limit of output range
+ 5 %
4.5 k 2 10 V
0 5 V
Lower limit of output range Upper limit of output range Lower limit of output range Lower limit of output range
1 5 V
* acc. to NAMUR NE 43
857-810
3
242
JUMPFLEX
Transducers
Temperature transducer for thermocouples of types J and K
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
IN
POWER
5
6
1
2
3
4
7
8
OUT+
GND 1
Us+
GND 2
TC+
TC
Conguration via:
DIP Switches
Short description:
The 857-810 Thermocouple Temperature Transducer is suitable for the connection of type
J and K thermocouples. On the output side, the thermocouple temperature transducer
converts the temperature signal into an analog standard signal.
Characteristics:
For thermocouples of type J and K
Cold junction compensation (on/off)
Calibrated scale switching
Sensor's wire break
Measuring range underflow/overflow
Clipping capability allows analog standard signal limitation to upper range values
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 24 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 44.7 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
3
243
3
= ON 857-810 DIP Switch Adjustability
Default Settings
All DIP switches are in OFF position for delivery.
Cold junction compensation on
Thermocouple Type J
Start temperature 0 C
End temperature 1000 C
Output signal 0 20 mA
Measuring range underow 0 mA
Measuring range overow 20.5 mA
Wire break 21 mA
DIP Switch S1
Cold junction compensation Sensor type Output signal
Measuring range
underow
Measuring range
overow
Wire break
1 2 3 Code OUT 4 5 6 7 8
on J E 0 20 mA
Lower limit of output range
- 5 % *
Upper limit of output range
+ 2,5 % *
Upper limit of output range
+ 5 % *
o K F 4 20 mA
G 0 10 mA
Lower limit of output range
Upper limit of output range
+ 2,5 %
Upper limit of output range
+ 5 %
H 2 10 mA
J 0 10 V
Lower limit of output range Upper limit of output range
Upper limit of output range
+ 5 %
K 2 10 V
L 0 5 V
Lower limit of output range Upper limit of output range Lower limit of output range
M 1 5 V
DIP 9 and 10 n.c. * acc. to NAMUR NE 43
DIP Switch S2
Start temperature End temperature
1 2 3 4 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F
225 437 625 1157 1025 1877
-200 -328 0 32 250 482 650 1202 1050 1922
-175 -283 10 50 275 527 675 1247 1075 1967
-150 -283 20 68 300 572 700 1292 1100 2012
-125 -193 30 86 325 617 725 1337 1125 2057
-100 -148 40 104 350 662 750 1382 1150 2102
-90 -130 50 122 375 707 775 1427 1175 2147
-80 -112 60 140 400 752 800 1472 1200 2192
-70 -94 70 158 425 797 825 1517 1225 2237
-60 -76 80 176 450 842 850 1562 1250 2282
-50 -58 90 194 475 887 875 1607 1275 2327
-40 -40 100 212 500 932 900 1652 1300 2372
-30 -22 125 257 525 977 925 1697 1325 2417
-20 -4 150 302 550 1022 950 1742 1350 2462
-10 14 175 347 575 1067 975 1787 1375 2507
0 32 200 392 600 1112 1000 1832 1400 2552
The minimum distance from the start temperature to the end temperature may not fall short of 100K degrees on the Celsius (C) scale or 212K degrees on the Fahrenheit (F) scale.
857-811
3
244
JUMPFLEX
Transducers
Temperature transducer for thermocouples of types J and K *
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT 1
IN
POWER
5
6
1
2
3
4
7
8
OUT+
GND 1
Us+
GND 2
TC+
TC
Conguration via:
DIP Switches Conguration
Software
Short description:
The 857-811 Thermocouple Temperature Transducer is suitable for the connection of type J and
K thermocouples. On the output side, the thermocouple temperature transducer converts the
temperature signal into an analog standard signal.
Characteristics:
FDT/DTM configuration interface
For thermocouples of type J and K (E, R, N, S, T, B, C)
Cold junction compensation (on/off)
Calibrated scale switching
Sensor's wire break
Measuring range underflow/overflow
Clipping capability allows analog standard signal limitation to upper range values
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 49.2 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
( * Setting of other types of sensors as well as output signal inversion using the
configuration software)
3
245
3
= ON 857-811
Default Settings
All DIP switches are in OFF position for delivery.
This is the position used to parameterize the device via FDT/DTB conguration software.
Cold junction compensation on
Thermocouple Type J
Start temperature 0 C
End temperature 1000 C
Output signal 0 20 mA
Measuring range underow 0 mA
Measuring range overow 20.5 mA
Wire break 21 mA
DIP Switch S2
Start temperature End temperature
1 2 3 4 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F 5 6 7 8 9 10 C F
225 437 625 1157 1025 1877
-200 -328 0 32 250 482 650 1202 1050 1922
-175 -283 10 50 275 527 675 1247 1075 1967
-150 -283 20 68 300 572 700 1292 1100 2012
-125 -193 30 86 325 617 725 1337 1125 2057
-100 -148 40 104 350 662 750 1382 1150 2102
-90 -130 50 122 375 707 775 1427 1175 2147
-80 -112 60 140 400 752 800 1472 1200 2192
-70 -94 70 158 425 797 825 1517 1225 2237
-60 -76 80 176 450 842 850 1562 1250 2282
-50 -58 90 194 475 887 875 1607 1275 2327
-40 -40 100 212 500 932 900 1652 1300 2372
-30 -22 125 257 525 977 925 1697 1325 2417
-20 -4 150 302 550 1022 950 1742 1350 2462
-10 14 175 347 575 1067 975 1787 1375 2507
0 32 200 392 600 1112 1000 1832 1400 2552
The minimum distance from the start temperature to the end temperature may not fall short of 100K degrees on the Celsius (C) scale or 212K degrees on the Fahrenheit (F) scale.
DIP Switch Adjustability
DIP Switch S1
Cold junction compensation Sensor type Output signal
Measuring range
underow
Measuring range
overow
Wire break
1 2 3 Code OUT 4 5 6 7 8
on J E 0 20 mA
Lower limit of output range
- 5 % *
Upper limit of output range
+ 2,5 % *
Upper limit of output range
+ 5 % *
o K F 4 20 mA
G 0 10 mA
Lower limit of output range
Upper limit of output range
+ 2,5 %
Upper limit of output range
+ 5 %
H 2 10 mA
J 0 10 V
Lower limit of output range Upper limit of output range
Upper limit of output range
+ 5 %
K 2 10 V
L 0 5 V
Lower limit of output range Upper limit of output range Lower limit of output range
M 1 5 V
DIP 9 and 10 n.c. * acc. to NAMUR NE 43
857-818
3
246
JUMPFLEX
Transducers
Ni Transducer for Ni 100, Ni 120, Ni 200, Ni 500, Ni 1000
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
IN
5
6
1
2
3
4
7
8
OUT+
GND 1
Us+
GND 2
POWER
Conguration via:
DIP Switches
Short description:
The 857-818 Ni Transducer (Ni = nickel) records signals from Ni sensors
featuring all standard characteristics. On the output side, the NI temperature
transducer converts the temperature signal into a standard analog signal.
Characteristics:
For Ni100, Ni120, Ni200, Ni500 and Ni1000 sensors
Calibrated scale switching
Clipping capability allows analog standard signal limitation to upper range
values
Safe 3-way isolation with 2.5 kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 50 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
247
3
= ON 857-818 DIP Switch Adjustability
DIP Switch S1
Start Temperature End Temperature
8 9 10 C 1 2 3 4 5 T / C 1 2 3 4 5 T / C 1 2 3 4 5 T / C
-60 0 100 200
-50 10 110 210
-40 20 120 220
-30 30 130 230
-20 40 140 240
-10 50 150 250
0 60 160 260
70 170 270
80 180 280
90 190 290
300
DIP Switch S1
Connection Technology Temperature Coe cient Sensor Type
1 2 3 4 5 6 7
2-conductor 6178 ppm/K Ni 100
3-conductor 5000 ppm/K Ni 120
4-conductor 6720 ppm/K Ni 200
Reserve Ni 500
Ni 1000
DIP Switch S2
Output Signal
Measuring Range
Underow
Measuring Range
Overow
Wire Break Short Circuit
6 7 8 Code OUT 9 10
0 20 mA E
Lower limit of output range
-5 % **
2
Upper limit of output range
+2.5 %*
2
Upper limit of output range
5 %*
2
Lower limit of output range
-12.5 % **
2
4 20 mA F
0 10 mA G
Lower limit of output range
Upper limit of output range
+2.5 %
Upper limit of output range
5 %
Lower limit of output range
2 10 mA H
0 10 V J
Lower limit of output range
Upper limit of output
range
Upper limit of output range
5 %
Upper limit of output range
5 %
2 10 V K
0 5 V L
Lower limit of output range
Upper limit of output
range
Lower limit of output range Lower limit of output range
1 5 V M
* but not when lower limit of output range = 0V or 0mA
*
2
acc. to NAMUR NE 43
Default Setting
All DIP switches are in OFF position for delivery.
Sensor connection 2-conductor
Sensor type NI 100
Temperature coe cient 6178 ppm/K
Start temperature 0 C
End temperature 100 C
Output signal 0 20 mA
Measuring range underow 0 mA
Measuring range overow 20.5 mA
Wire break 21 mA
Short circuit 0 mA
857-819
3
248
JUMPFLEX
Transducers
Millivolt transducer; Records all mV signals ranging from -100 mV to +100 mV; 0 mV ... 1000 mV. Application: Recording of lambda probes
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
U,I
IN
mV
POWER
5
6
1
2
3
4
7
8
OUT+
GND 1
Us+
GND 2
IN+
IN
N.C.
N.C.
Conguration via:
DIP Switches Conguration
Software
Short description:
The 857-819 Millivolt Transducer converts input millivolt signals into an analog
standard signal on the output side.
Characteristics:
FDT/DTM configuration interface
Calibrated scale switching
Clipping capability allows analog standard signal limitation to upper range
values
Safe 3-way isolation with 2.5 kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 50 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4
Shipbuilding g
Accessories see pages 268 ... 271
( * Additional setting options are possible via FDT-/DTM configuration tool.)
3
249
3
= ON 857-819
Input
Start value
DIP S1
1 2 3 4 5 6 7 mV 1 2 3 4 5 6 7 mV 1 2 3 4 5 6 7 mV
-34 34
-100 -32 36
-98 -30 38
-96 -28 40
-94 -26 42
-92 -24 44
-90 -22 46
-88 -20 48
-86 -18 50
-84 -16 52
-82 -14 54
-80 -12 56
-78 -10 58
-76 -8 60
-74 -6 62
-72 -4 64
-70 -2 66
-68 0 68
-66 2 70
-64 4 72
-62 6 74
-60 8 76
-58 10 78
-56 12 80
-54 14 82
-52 16 84
-50 18 86
-48 20 88
-46 22 90
-44 24 92
-42 26 94
-40 28 96
-38 30 98
-36 32 100
Input
End value
DIP S1 DIP S2 DIP S1 DIP S2 DIP S1 DIP S2 DIP S1 DIP S2
8 9 10 1 2 3 4 mV 8 9 10 1 2 3 4 mV 8 9 10 1 2 3 4 mV 8 9 10 1 2 3 4 mV
-34 34 100
-100 -32 36 200
-98 -30 38 300
-96 -28 40 400
-94 -26 42 500
-92 -24 44 600
-90 -22 46 700
-88 -20 48 800
-86 -18 50 900
-84 -16 52 1000
-82 -14 54
-80 -12 56
-78 -10 58
-76 -8 60
-74 -6 62
-72 -4 64
-70 -2 66
-68 0 68
-66 2 70
-64 4 72
-62 6 74
-60 8 76
-58 10 78
-56 12 80
-54 14 82
-52 16 84
-50 18 86
-48 20 88
-46 22 90
-44 24 92
-42 26 94
-40 28 96
-38 30 98
-36 32 100
DIP Switch S2
Output signal
Measuring Range Underow Measuring Range Overow
Code OUT 6 7 8 9 10
E 0 20 mA Lower limit of output range - 5 % * Upper limit of output range + 2,5 % *
F 4 20 mA (0 mA / 1,9 mA / 3,8 mA / 0 V / 0,95 V / 1,9 V) (10,25 mA / 20,5 mA / 5,125 V / 10,25 V)
G 0 10 mA
Transducers
KTY Transducer
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
U; I
POWER DO
KTY
5
6
1
2
3
4
7
8
OUT+
GND 1
Us+
GND 2
IN+
IN-
DO
GND 2
Conguration via:
DIP Switches
Short description:
The 857-820 KTY Transducer records signals from KTY sensors featuring all
standard characteristics. On the output side, the KTY temperature transducer
converts the temperature signal into a standard analog signal.
Characteristics:
Supports all standard KTY sensors
Calibrated scale switching
Clipping capability allows analog standard signal limitation to upper range
values
Safe 3-way isolation with 2.5 kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 50 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
251
3
= ON 857-820 DIP Switch Adjustability
DIP Switch S1
Sensor Type
1 2 3 4
KTY81-110, KTY81-120, KTY82-110, KTY82-120
KTY81-121, KTY82-121
KTY81-122, KTY82-122
KTY81-150, KTY82-150
KTY81-210, KTY81-220, KTY82-210, KTY82-220
KTY81-221, KTY82-221
KTY81-222, KTY82-222
KTY81-250, KTY82-250
KTY83-110, KTY83-120,
KTY83-121
KTY83-122
KTY83-150
KTY83-151
KTY84-130, KTY84-150
KTY84-151
KTY16, KTY19, ST13, ST20
DIP Switch S1
Output Signal
Measuring Range
Underow
Measuring Range
Overow
Wire Break Short Circuit
6 7 8 Code OUT 9 10
0 20 mA E
Lower limit of output range
-5 % **
2
Upper limit of output range
+2.5 %*
2
Upper limit of output range
5 %*
2
Lower limit of output range
-12.5 % **
2
4 20 mA F
0 10 mA G
Lower limit of output range
Upper limit of output range
+2.5 %
Upper limit of output range
5 %
Lower limit of output range
2 10 mA H
0 10 V J
Lower limit of output range
Upper limit of output
range
Upper limit of output range
5 %
Upper limit of output range
5 %
2 10 V K
0 5 V L
Lower limit of output range
Upper limit of output
range
Lower limit of output range Lower limit of output range
1 5 V M
* but not when lower limit of output range = 0V or 0mA
*
2
acc. to NAMUR NE 43
Default Setting
All DIP switches are in OFF position for delivery.
Sensor type KTY81-110, KTY81-120, KTY82-110, KTY82-120
Start temperature 0 C
End temperature 100 C
Output signal 0 20 mA
Measuring range underow 0 mA
Measuring range overow 20.5 mA
Wire break 21 mA
Short circuit 0 mA
Digital output not active
DIP Switch S2
Digit Output DO Signaling
9 10
DO not active
DO Us+ switching
DO GND switching
DIP Switch S2
Start Temperature End Temperature
1 2 3 C 4 5 6 7 8 C 4 5 6 7 8 C 4 5 6 7 8 C
-55 0 100 200
-50 10 110 210
-40 20 120 220
-30 30 130 230
-20 40 140 240
-10 50 150 250
0 60 160 260
70 170 270
80 180 280
90 190 290
300
857-809
3
252
JUMPFLEX
Transducers
Potentiometer Position Transducer
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
1 0%
100%
2
3
4 DO
5
6
7
8
OUT
OUT+
GND 1
Us+
GND 2 DO (GND 2)
POWER
IN
Conguration via:
DIP Switches Push/Slide Switch
Short description:
The 857-809 Potentiometer Position Transducer records resistance signals (e.g.,
from potentiometers), converting them into an analog standard signal. The de-
vice is supplied with 24VDC (nominal voltage). Configuration is performed via
DIP switches.
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm 2.5 mm / AWG 28 14
fine-stranded:
0.34 mm 2.5 mm / AWG 22 14
Strip lengths 9 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 49.2 g
Standards and approvals:
r UL 508 (pending)
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
3
253
3
= ON 857-809 DIP Switch Adjustability
Start Value
DIP S1 Resistor
2 3 4 5 6
0
*
0
10
11
12
13
15
16
18
20
22
24
27
30
33
36
39
43
47
51
56
62
68
75
82
91
40
50
60
70
80
90
End Value
DIP S1 DIP S2 Resistor
7 8 9 10 1
100000
*
0
10
11
12
13
15
16
18
20
22
24
27
30
33
36
39
43
47
51
56
62
68
75
82
91
40
50
60
70
80
90
Factor of Initial Value Factor of End Value Output Output Signal Range
2 3 4 5 6 7 8
x1
*
x1
*
Current* 0 10 V/0 20 mA
*
x10 x10 Voltage 2 10 V/4 20 mA
x100 x100 0 5 V/0 10 mA
x1000 x1000 1 5 V/2 10 mA
DIP Switch S2
9 10 Measuring Range Underow Measuring Range Overow Wire Break
Upper limit of output range
*1
+2.5 %
Lower limit of output range
*1
-5 %
Upper limit of output range
*1
+5 %
Transducers
Frequency transducer 0.1 Hz ... 120 kHz
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
in
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT
U, I
IN
f
POWER
5
6
1
2
3
4
7
8
OUT+
GND 2
Us+
GND 3
+8,2 V(Namur)
f
IN
GND 1
NPN/PNP
Conguration via:
DIP Switches
Short description:
The 857-500 Frequency Transducer collects 0.1120kHz signals from
NAMUR, NPN or PNP sensors and converts them into analog standard signals.
Characteristics:
Signal acquisition from NAMUR, NPN or PNP sensors
Calibrated scale switching
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 38.7 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
Refer to following pages for DIP Switch Table and Pin Assignments.
3
258
= ON 857-500
AC/DC
AC
U
t
DIP Switch Adjustability = ON
DIP Switch S1
Source Input Coupling
Operation with disturbed frequency signals for acceptable signal level
(applies only to f
IN
input)
1 2 3 4 5
Frequency generator or NPN/PNP transistor
outputs with pull-up or pull-down resistor
AC/DC High Low
NAMUR AC (without DC), see Figure 1 > 1.5 V < 0.4 V
IN
24 V
0 V
OUT
POWER
BN
BK
BU
+
IN
IN
R
R
24 V
0 V
OUT
POWER
BN
BK
BU
+
IN
24 V
0 V
OUT
POWER
BN
BK
BU
+
24 V
0 V
IN
OUT
POWER
BN
BU
24 V
0 V
IN
OUT
POWER
BN
BU
2-Conductor DC (Mechanical Contact)
857-500, Wiring Material
2-Conductor DC NAMUR Sensor
NPN Transistor Output with Pull-Up Resistor NPN Transistor Output
PNP Transistor Output PNP Transistor Output with Pull-Down Resistor
Frequency Generator
3
260
JUMPFLEX
Transducers
Threshold value switch with analog input and changeover relay output
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
IN+
GND 1
IN
U,I
Us+
GND 2
POWER
DO DO
12
11
14
1
2
3
4
5
6
7
8
Conguration via:
DIP Switches Conguration
Software
Push/Slide Switch
Short description:
The threshold value switch for analog signals monitors analog standard signals and
reports signals exceeding a preset threshold.
Characteristics:
FDT/DTM configuration interface
Digital switching output
Changeover contact relay output
Calibrated scale switching
Threshold value configuration via DIP switches and teach-in function via push/sli-
de switch
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 49 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g
Accessories see pages 268 ... 271
( * Additional setting options are possible via FDT-/DTM configuration tool.)
857-531
3
261
3
= ON 857-531 DIP Switch Adjustability
DIP Switch S1
Congurable rise/fall delay time in sec.
Digital output DO
Signaling
6 7 8 9 10
0 DO not active
1 GND U
N
(switching)
2 U
N
GND
(switching)
3
4
5
8
10
DIP Switch S1
Input signal limits
0.25 V; 0.5 mA
Hysteresis
Code IN 1 2 3 4 5
c 10 V 5 mV; 10 A
j 0 10 V 10 mV, 20 A
k 2 10 V
l 0 5 V
m 1 5 V
d 5 V
0 15 V
0 30 V
a 20 mA
e 0 20 mA
f 4 20 mA
g 0 10 mA
h 2 10 mA
b 10 mA
Default Settings
All DIP switches are in OFF position for delivery.
Input
Input range 10 V
Hysteresis 5 mV
Output
Congurable rise/fall delay time 0 s
Digital output DO not active
Push/Slide Switch Operation:
SP1 SP2
SP1 SP2
SP1 SP2
SP1
SP1
SP1 SP2
SP1 SP2
SP1 SP2
SP1 SP2
SP1 SP2
SP1
SP1
Leave param. mode without
storing a value
Param. mode
Param. mode
Param. mode
Param. mode
Param. mode
Param. mode
Param. mode
Leave
param. mode
Leave
param. mode
Leave
param. mode
Leave
param. mode
Leave
param. mode
Leave
param. mode
Leave
param. mode
Press
for
1 sec.
Yellow
LED
ashes
Red
LED
ashes
briey
No
ashing
LED
857-550
3
262
JUMPFLEX
Transducers
Current transducer AC/DC 0 ... 1 A, 0 ... 5 A
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT IN
POWER
5
6
1
2
3
4
7
8
OUT+
GND 2
Us+
GND 3
IN 1A
(GND 1)
IN 5A
(GND 1)
DO
(GND 3)
GND 1
DO
Conguration via:
DIP Switches
Short description:
The 857-550 Current Transducer measures 01A and 05A AC/DC currents and
converts the input signal to a standard analog signal at the output.
Characteristics:
True RMS measurement or arithmetic mean value
Switchable filter function
Switching between measuring ranges is calibrated
Safe 3-way isolation with 2.5kV test voltage to EN 61140
Extremely fast response times
Measuring range overflow indication
Description Item No.
Pack.
Unit
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 50 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
HW/SW 03/02
3
263
3
= ON 857-550 DIP Switch Adjustability
DIP Switch S1
Input Signal Measuring Method Filter Output Signal
1 2 3 4 5 6
5 A Mean square value o 0 ... 20 mA
1 A Arithmetic mean value active 4 ... 20 mA
0 ... 10 V
2 ... 10 V
0 ... 10 mA
2 ... 10 mA
0 ... 5 V
1 ... 5 V
DIP Switch S1
Measuring Range Underow Measuring Range Overow
Overcurrent
(Input Signal - End Value + 20%)
Digit Output DO
Signaling
7 8 9 10
Lower limit of measuring range - 5 %
*
Upper limit of measuring range + 2.5 %
*
Upper limit of measuring range + 5 %
*
DO not active
Lower limit of measuring range Upper limit of measuring range + 2.5 % Upper limit of measuring range + 5 % DO Us+ switching
Lower limit of measuring range Upper limit of measuring range Lower limit of measuring range DO GND switching
Lower limit of measuring range Upper limit of measuring range Upper limit of measuring range
*
acc. to NAMUR NE 43
Default Setting
All DIP switches are in OFF position for delivery.
Input
Input Signal 0 ... 5 A
Measuring Method Mean square value
Output
Output Signal 0 ... 20 mA
Measuring Range Underow 0 mA
Measuring Range Overow 20.5 mA
Overcurrent 21 mA
Digital Output DO not active
Filter not active
The digital output (DO) signals error messages and can be congured as follows: 24 V 0 V/0 V 24 V.
In order to increase the switching current of the DO, the latter may be expanded by a relay. Thanks to the contour uniformity of Series 857, for example, a 857-304
Relay can be snapped in next to it. This output can be quickly and easily expanded to a switching current of 6A by simply using an adjacent jumper (859-402).
Application example:
Digital Output DO/Signaling
L1
Current
transformer
250 A/ 1 A
LED indication
24 V/500 mA
PLC/
LED indication
e.g. 787-1002
16.8 ... 31.2 V
AC 230 V
857-552
3
264
JUMPFLEX
Transducers
Rogowski-Messumformer
<_________ 94 mm/3.68 in _________> 6 mm/0.23 in
<
_
_
_
_
_
_
_
_
_
9
6
m
m
/
3
.
7
6
i
n
_
_
_
_
_
_
_
_
_
>
____________
_>
_ >
OUT IN
POWER
5
6
1
2
3
4
7
8
OUT+
GND 2
Us+
GND 3
RC1+
(GND 1)
RC2+
(GND 1)
DO
(GND 3)
GND 1
DO
DIP Switches
Conguration via:
Short description:
The Rogowski transducer records RMS values from alternating currents via a Rogowski
coil, converting the input signal into a standard analog signal on the output side.
Characteristics:
Supports different types of Rogowski coils
True RMS measurement (TRMS)
Configurable output signal
Configuration via DIP switch
Safe 3-way isolation with 2.5 kV test voltage to EN 61140
No current bar interruption during installation
Measuring range overflow indication
Description Item No.
Pack.
Unit
Height from upper-edge of DIN 35 rail 857-552 1
Rogowski-Messumformer
Technical Data
Configuration:
Configuration DIP switch
Input:
Input signal RC1 500 A: Sensitivity 10.05 mV
RC2A 2000 A: Sensitivity 40.2 mV
RC2B: Sensitivity 100 mV
50/60 Hz sinusoidal and distorted
sinusoidal signals (e.g. leading edge and
trailing edge)
Frequency range 16 Hz ... 100 Hz
Output:
Output signal Voltage:
0 ... 5 V, 1 ... 5 V, 0 ... 10 V, 2 ... 10 V
Current:
0 ... 10 mA, 2 ... 10 mA,
0 ... 20 mA, 4 ... 20 mA
Overcurrent 0 % or +5 % (e. g. 10.5 V/21 mA)
Overrange / measuring range 0 % or +2.5 %
Load impedance Current 600 , Voltage 1000
Measuring procedure True RMS measurement
Filter (T
10-90
) 600 ms
Output - Digital
Max. switching voltage Supply voltage applied
Max. continuous current 500 mA
General specifications:
Resolution 500A measuring range: 250 mA,
2000A measuring range: 1000 mA
Measuring procedure True RMS measurement
Response time 1.5 ms + signal cycle duration
Voltage supply V
N
24 V DC
Max. operating frequency < 1 kHz
Response time (T
10-90
) max. 60 ms
Technical Data
General specifications:
Linearity 0,1 %
Temperature coefficient 0.01 %/K
Messabweichung < 1 %
Leitungslnge < 3 m (to the Rogowski coil)
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -40 C ... +85 C
Safety and protection:
Test voltage (input/output/supply) 2.5 kV AC, 50 Hz, 1 min.
Connection and type of mounting:
Wire connection CAGE CLAMP
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 36.2 g
Standards and approvals:
Conformity marking 1
r UL 508 (pending)
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g (pending)
Accessories see pages 268 ... 271
Rogowski coils:
RT500: 0758-0950/0000-0500
RT2000: 0758-0950/0000-2000
HW/SW 01/01
3
265
3
= ON 857-552
L1
DIP Switch Adjustability
Default Setting
All DIP switches are in OFF position for delivery.
Input
Input Signal RC1 500 A
Measuring Method Mean square value
Output
Output Signal 0 ... 20 mA
Measuring Range Underow 0 mA
Measuring Range Overow 20.5 mA
Overcurrent 21 mA
Digital Output DO not active
Filter not active
DIP Switch S1
DIP-Schalter S1
Measuring Range Underow Measuring Range Overow
Overcurrent
(Input Signal - End Value + 20%)
Digit Output DO
Signaling
7 8 9 10
(+20 %) Upper limit of measuring range + 2.5 %
*
Upper limit of measuring range + 5 %
*
DO not active
Lower limit of measuring range Upper limit of measuring range + 2.5 % Upper limit of measuring range + 5 % DO Us+ switching
Lower limit of measuring range Upper limit of measuring range Lower limit of measuring range DO GND switching
Lower limit of measuring range Upper limit of measuring range Upper limit of measuring range
Input Signal RC Conguration Input Filter Output Signal
1 2 3 4 5 6
RC1 = RT500 from LEM RC2 = RT2000 from LEM o 0 ... 20 mA
RC2 RC2 = 100 mV e. => 1 kA active 4 ... 20 mA
0 ... 10 V
2 ... 10 V
0 ... 10 mA
2 ... 10 mA
0 ... 5 V
1 ... 5 V
*
acc. to NAMUR NE 43
Application example:
The digital output (DO) signals error messages and can be congured as follows: 24 V 0 V/0 V 24 V.
In order to increase the switching current of the DO, the latter may be expanded by a relay. Thanks to the contour uniformity of Series 857, for example, a 857-304
Relay can be snapped in next to it. This output can be quickly and easily expanded to a switching current of 6A by simply using an adjacent jumper (859-402).
Digital Output DO/Signaling
LED indication
24 V/500 mA
PLC/
LED indication
e.g. 787-1002
16.8 ... 31.2 V
AC 230 V
857-979
3
266
JUMPFLEX
S
Cross sections solid:
0.08 mm ... 2.5 mm / AWG 28 ... 14
fine-stranded:
0.34 mm ... 2.5 mm / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 30 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g
Accessories see pages 268 ... 271
Technical Data
3
267
3
857-979
2
1
Application example:
Power supply for 8 JUMPFLEX modules with plugged interface adapter
WAGO interface adapter, 857-980
WAGO ribbon cable, 706-100/1602-200, 16-pole socket/open-ended
Push-in type jumper bar, 9-way, 859-409
759-370
3
268
WAGOframe
FDT frame application for parameterization, commissioning and diagnostics of devices with DTM device driver
WAGOframe: Parameterizing a JUMPLEX
DTMs.
For example, this wizard guides the user through the different operating modes
of DTM device drivers.
Depending on the PC communication interface used, an appropriate communi-
cation cable including DTM is required.
Description Item No.
Pack.
Unit
WAGOframe 759-370 1
Accessories Item No.
Pack.
Unit
857 Series JUMPFLEX
) or to WAGO-I/O-SYSTEM buscouplers/controllers.
Notice:
Using the WAGO 759-923 USB Service Cable in combination with some of
the programmable fieldbus controllers requires a certain firmware version or
higher:
750-841 as from firmware version 12
750-872/0020-0000 as from firmware version 2
Description Item No.
Pack.
Unit
WAGO USB Communication Cable,
length 2.5 m 750-923 1
WAGO USB Communication Cable,
length 5 m 750-923/000-001 1
Technical Data
USB specification 2.0 compatible/full-speed device
Operating system Microsoft
Windows
2000;
Microsoft
Windows
XP Professional;
Microsoft
Windows
Vista
;
Microsoft
Windows
7
Operating temperature -25 C ... +70 C
Interface USB Type A/m
Length 2.5 m (750-923)
5 m (750-923/000-001)
Connector dimensions (WxHxD) 15 x 50 x 19
Test voltage 2.5 kV, 50 Hz, 1 min.
EMC: 1 - immunity to interference acc. to EN 61000-4-3, EN 61000-4-6
EMC: 1 - emission of interference acc. to EN 55022
3
270
JUMPFLEX
Interface
Adapter (Item No. 857-980)
Description Item No.
Pack.
Unit
Description Item No.
Pack.
Unit
8-channel adapter
with 16-pin ribbon cable connector
Analog
857-980 1 WAGO ribbon cable 16/16, 1m long 706-753/301-100 1
WAGO ribbon cable 16/16, 2m long 706-753/301-200 1
WAGO ribbon cable 16/16, 3m long 706-753/301-300 1
Technical Data Technical Data
Connection type, signal level 16-pin ribbon cable connector
acc. to DIN 41651
Ports 2 x 16-pole female connector
acc. to DIN 41651
Performance level 3 Wire cross-section 0.14 mm
2
LiYY
Contact resistance 20m Color coding acc. to DIN VDE 47100
Current carrying capacity 1A Current per channel max. 1 A
Test voltage 500 V / 50 Hz / 1 min. Operating temperature -25 C ... +70 C
Overvoltage category III Degree of protection IP20
Degree of pollution 2 Length 1 m (706-753/301-100)
2 m (706-753/301-200)
3 m (706-753/301-300)
COMPACT Power
L
N
DC+
DC+
DC -
DC -
Primary switch mode power supply unit
Prepared for class II equipment
Natural convection cooling when horizontally mounted
Stage profile, ideal for distribution boards or distribution boxes
At reduced output current, any type of mounting positions are possible (e.g.,
horizontal, overhead mounting)
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 VDC / 2A
787-1001 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 373 VDC
Input voltage derating < 100 VAC: Ia max. 1.5 A
Frequency 44 ... 66 Hz; 0 Hz
Input current Ii 0.6 A at 110 VAC / 0.4 A at 230 VAC
Discharge current 1mA typ.
Inrush current < 30 A, NTC
Mains failure hold-up time > 10 ms at 110 VAC /
> 80 ms at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC
Output voltage range 10.8 ... 18 VDC adjustable
Output current Io 2 A at 12 VDC
0.75 A at 18 VDC
max. 1.4 A (12 VDC) in any mounting
position
Factory preset 12 VDC
Adjustment accuracy 2 %
Residual ripple < 150 mVpp at 20 MHz
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Va)
Efficiency / power losses:
Efficiency 80 % typ.
Power loss P
V
2.6 W (230 VAC/no load),
6.0 W (230 VAC/rated load)
Max. power loss P
V
6 W typ. (100 VAC / 12 VDC, 2 A)
Fuse protection:
Internal fuse 2 AT
External fuse Circuit breakers 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +55 C
Storage temperature -25 C ... +80 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Enclosure Plastic, light gray,
Flammability class V0 acc. to UL94
Test voltage pri. - sec. 4.2 kV DC
Protection class Prepared for class II equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection < 30 VDC (in the event of a fault)
Short circuit protection yes
No-load proof yes
Feedback voltage max. 20 VDC
Parallel operation yes
Series connection yes
MTBF 500000 h
Connection and type of mounting:
Wire connection Input/Output: WAGO 740 Series
Cross sections Input/Output:
0.08 ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output:
6 ... 7 mm / 0.24 ... 0.28 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 54 x 89 x 59
Length: 55 mm, from upper-edge of DIN 35 rail
Weight 180 g
Standards and approvals:
Standards/Specifications EN 60950 (SELV), EN 61204-3,
UL 60950, UL 508, GL
787-1011
4
285
4
Switched-Mode Power Supply
EPSITRON
COMPACT Power
L
N
DC+
DC+
DC -
DC -
Primary switch mode power supply unit
Prepared for class II equipment
Natural convection cooling when horizontally mounted
Stage profile, ideal for distribution boards or distribution boxes
At reduced output current, any type of mounting positions are possible (e.g.,
horizontal, overhead mounting)
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 VDC / 4A
787-1011 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 373 VDC
Input voltage derating < 100 VAC: Ia max. 3.5 A
Frequency 44 ... 66 Hz; 0 Hz
Input current Ii 0.9 A at 110 VAC / 0.5 A at 230 VAC
Discharge current 1mA typ.
Inrush current < 30 A, NTC
Mains failure hold-up time > 10 ms at 110 VAC /
> 80 ms at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC
Output voltage range 10.5 ... 15.5 VDC adjustable
Output current Io 4 A at 12 VDC
max. 2.4 A in any mounting position
Factory preset 12 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp at 20 MHz
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Va)
Efficiency / power losses:
Efficiency 85 % typ.
Power loss P
V
2.2 W (230 VAC/no load),
8.5 W (230 VAC/rated load)
Max. power loss P
V
9 W typ. (100 VAC / 12 VDC, 4 A)
Fuse protection:
Internal fuse 2 AT
External fuse Circuit breakers 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +55 C
Storage temperature -25 C ... +80 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Enclosure Plastic, light gray,
Flammability class V0 acc. to UL94
Test voltage pri. - sec. 4.2 kV DC
Protection class Prepared for class II equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection < 30 VDC (in the event of a fault)
Short circuit protection yes
No-load proof yes
Feedback voltage max. 20 VDC
Parallel operation yes
Series connection yes
MTBF 500000 h
Connection and type of mounting:
Wire connection Input/Output: WAGO 740 Series
Cross sections Input/Output:
0.08 ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output:
6 ... 7 mm / 0.24 ... 0.28 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 72 x 89 x 59
Length: 55 mm, from upper-edge of DIN 35 rail
Weight 255 g
Standards and approvals:
Standards/Specifications EN 60950 (SELV), EN 61204-3,
UL 60950*, UL 508*, GL
(* pending)
787-1021
4
286
Switched-Mode Power Supply
EPSITRON
COMPACT Power
L
N
DC+
DC+
DC -
DC -
Primary switch mode power supply unit
Prepared for class II equipment
Natural convection cooling when horizontally mounted
Stage profile, ideal for distribution boards or distribution boxes
At reduced output current, any type of mounting positions are possible (e.g.,
horizontal, overhead mounting)
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 VDC / 6.5A
787-1021 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 373 VDC
Input voltage derating max. 6 A (< 100 VAC) /
5.5 A (< 90 VAC)
Frequency 44 ... 66 Hz; 0 Hz
Input current Ii 1.6 A at 110 VAC / 0.9 A at 230 VAC
Discharge current 1mA typ.
Inrush current < 30 A, NTC
Mains failure hold-up time > 15 ms at 110 VAC /
> 100 ms at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC
Output voltage range 10.5 ... 15.5 VDC adjustable
Output current Io 6.5 A at 12 VDC
0.75 A at 18 VDC
max. 3.9 A (12 VDC) in any mounting
position
Factory preset 12 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp at 20 MHz
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Va)
Efficiency / power losses:
Efficiency 87 % typ.
Power loss P
V
< 1 W (no load) /
15 W (rated load)
Max. power loss P
V
15 W typ. (100 VAC / 12 VDC, 6.5 A)
Fuse protection:
Internal fuse 4 AT
External fuse Circuit breakers 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +55 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Enclosure Plastic, light gray,
Flammability class V0 acc. to UL94
Test voltage pri. - sec. 4.2 kV DC
Protection class Prepared for class II equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection < 30 VDC (in the event of a fault)
Short circuit protection yes
No-load proof yes
Feedback voltage max. 20 VDC
Parallel operation yes
Series connection yes
MTBF 500000 h
Connection and type of mounting:
Wire connection Input/Output: WAGO 740 Series
Cross sections Input/Output:
0.08 ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output:
6 ... 7 mm / 0.24 ... 0.28 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 90 x 89 x 59
Length: 55 mm, from upper-edge of DIN 35 rail
Weight 300 g
Standards and approvals:
Standards/Specifications EN 60950 (SELV), EN 61204-3, GL,
UL 60950*, UL 508*
(* pending)
787-1002
4
287
Switched-Mode Power Supply
EPSITRON
COMPACT Power
L
N
DC+
DC+
DC -
DC -
Primary switch mode power supply unit
Prepared for class II equipment
Natural convection cooling when horizontally mounted
Stage profile, ideal for distribution boards or distribution boxes
At reduced output current, any type of mounting positions are possible (e.g.,
horizontal, overhead mounting)
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 VDC / 1.3A
787-1002 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 373 VDC
Input voltage derating < 100 VAC: Ia max. 1 A
Frequency 44 ... 66 Hz; 0H z
Input current Ii 0.7 A at 110 VAC / 0.5 A at 230 VAC
Discharge current 1mA typ.
Inrush current < 30 A, NTC
Mains failure hold-up time > 10 ms at 110 VAC /
> 80 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC
Output voltage range 22.8 ... 26.4 VDC adjustable
Output current Io 1.3 A at 24 VDC
max. 0.9 A in any mounting position
Factory preset 24 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp at 20 MHz
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Va)
Efficiency / power losses:
Efficiency 82 % typ.
Power loss P
V
2.6 W (230 VAC/no load),
7.0 W (230 VAC/rated load)
Max. power loss P
V
7.3 W typ. (100 VAC / 24 VDC, 1.3 A)
Fuse protection:
Internal fuse 2 AT
External fuse Circuit breakers 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +55 C
Storage temperature -25 C ... +80 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Enclosure Plastic, light gray,
Flammability class V0 acc. to UL94
Test voltage pri. - sec. 4.2 kV DC
Protection class Prepared for class II equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection < 40 VDC (in the event of a fault)
Short circuit protection yes
No-load proof yes
Feedback voltage max. 30 VDC
Parallel operation yes
Series connection yes
MTBF 500000 h
Connection and type of mounting:
Wire connection Input/Output: WAGO 740 Series
Cross sections Input/Output:
0.08 ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output:
6 ... 7 mm / 0.24 ... 0.28 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 54 x 89 x 59
Length: 55 mm, from upper-edge of DIN 35 rail
Weight 180 g
Standards and approvals:
Standards/Specifications EN 60950 (SELV), EN 61204-3,
UL 60950, UL 508, GL
787-1012
4
288
Switched-Mode Power Supply
EPSITRON
COMPACT Power
L
N
DC+
DC+
DC -
DC -
Primary switch mode power supply unit
Prepared for class II equipment
Natural convection cooling when horizontally mounted
Stage profile, ideal for distribution boards or distribution boxes
At reduced output current, any type of mounting positions are possible (e.g.,
horizontal, overhead mounting)
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 VDC / 2.5A
787-1012 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 373 VDC
Input voltage derating < 100 VAC: Ia max. 2.0 A
< 90 VAC: Ia max. 1.8 A
Frequency 44 ... 66 Hz; 0 Hz
Input current Ii 1.4 A at 110 VAC / 0.6 A at 230 VAC
Discharge current 1mA typ.
Inrush current < 30 A, NTC
Mains failure hold-up time > 10 ms at 110 VAC /
> 80 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC
Output voltage range 22.8 ... 26.4 VDC adjustable
Output current Io 2.5 A at 24 VDC
max. 1.6 A in any mounting position
Factory preset 24 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp at 20 MHz
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Va)
Efficiency / power losses:
Efficiency 88 % typ.
Power loss P
V
2.2 W (230 VAC/no load),
8.5 W (230 VAC/rated load)
Max. power loss P
V
10.5 W typ. (100 VAC / 24 VDC, 2.5 A)
Fuse protection:
Internal fuse 2 AT
External fuse Circuit breakers 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +55 C
Storage temperature -25 C ... +80 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Enclosure Plastic, light gray,
Flammability class V0 acc. to UL94
Test voltage pri. - sec. 4.2 kV DC
Protection class Prepared for class II equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection < 40 VDC (in the event of a fault)
Short circuit protection yes
No-load proof yes
Feedback voltage max. 30 VDC
Parallel operation yes
Series connection yes
MTBF > 500000 h
Connection and type of mounting:
Wire connection Input/Output: WAGO 740 Series
Cross sections Input/Output:
0.08 ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output:
6 ... 7 mm / 0.24 ... 0.28 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 72 x 89 x 59
Length: 55 mm, from upper-edge of DIN 35 rail
Weight 255 g
Standards and approvals:
Standards/Specifications EN 60950 (SELV), EN 61204-3,
UL 60950, UL 508, GL
787-1022
4
289
4
Switched-Mode Power Supply
EPSITRON
COMPACT Power
L
N
DC+
DC+
DC -
DC -
Primary switch mode power supply unit
Prepared for class II equipment
Natural convection cooling when horizontally mounted
Stage profile, ideal for distribution boards or distribution boxes
At reduced output current, any type of mounting positions are possible (e.g.,
horizontal, overhead mounting)
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 VDC / 4A
787-1022 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 373 VDC
Input voltage derating on request
Frequency 44 ... 66 Hz; 0 Hz
Input current Ii 1.6 A at 110 VAC / 0.9 A at 230 VAC
Discharge current 1mA typ.
Inrush current < 30 A, NTC
Mains failure hold-up time > 15 ms at 110 VAC /
> 100 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC
Output voltage range 22.8 ... 26.4 VDC adjustable
Output current Io 4 A at 24 VDC
max. 2.4 A in any mounting position
Factory preset 24 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp at 20 MHz
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Va)
Efficiency / power losses:
Efficiency 88 % typ.
Power loss P
V
0.8 W (230 VAC/no load),
13.1 W (230 VAC/rated load)
Max. power loss P
V
14.8 W typ. (264 VAC / 24 VDC, 4 A)
Fuse protection:
Internal fuse 4 AT
External fuse Circuit breakers 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +55 C
Storage temperature -25 C ... +80 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Enclosure Plastic, light gray,
Flammability class V0 acc. to UL94
Test voltage pri. - sec. 4.2 kV DC
Protection class Prepared for class II equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection < 40 VDC (in the event of a fault)
Short circuit protection yes
No-load proof yes
Feedback voltage max. 30 VDC
Parallel operation yes
Series connection yes
MTBF 500000 h
Connection and type of mounting:
Wire connection Input/Output: WAGO 740 Series
Cross sections Input/Output:
0.08 ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output:
6 ... 7 mm / 0.24 ... 0.28 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 90 x 89 x 59
Length: 55 mm, from upper-edge of DIN 35 rail
Weight 310 g
Standards and approvals:
Standards/Specifications EN 60950 (SELV), EN 61204-3,
UL 60950*, UL 508*, GL
(* pending)
787-712
4
290
Switched-Mode Power Supply
EPSITRON
ECO Power
L
N
3
DC+
DC+
DC
DC
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
for DIN 35 rail
787-712 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 130 ... 373 VDC
(use of DC requires external protection)
Frequency 47 - 63 Hz
Input current Ii 0.7 A typ. at 230 VAC;
1.2 A at 115 VAC
Discharge current < 1 mA
Inrush current < 30 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22 ... 28 VDC adjustable
Output current Io 2.5 A at 24 V DC
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 100 mVpp to 20 MHz
Overload behavior Constant power (in overload range:
1.15 ... 1.4 x Ia); shutdown and automatic
restart in the event of a short circuit
Operational indication LED green (24 V DC o.k.),
LED red (overload)
Efficiency / power losses:
Efficiency 82 % typ.
Power loss P
V
8.3 W (at 230 VAC and 2.5 ADC)
Max. power loss P
V
11.5 W (at 110 VAC and 2.75 ADC)
Fuse protection:
Internal fuse F 3.15 A / 250 V
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: NTC
Technical Data
Environmental requirements:
Ambient operating temperature -10 C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 95 % (no condensation)
Derating -3.3 % / K (> 55 C at 230 VAC)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 3 kV AC / 1.5 kV AC / 0.5 kV AC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage 28 VDC
Parallel operation yes
Series connection yes
MTBF 480000 h (acc. IEC 61709)
Connection and type of mounting:
Wire connection CAGE CLAMP
ECO Power
L
N
3
DC+
DC+
DC
DC
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
for DIN 35 rail
787-722 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 130 ... 373 VDC
(use of DC requires external protection)
Frequency 47 - 63 Hz
Input current Ii 1.0 A typ. at 230 VAC;
2.0 A at 115 VAC
Discharge current < 3.5mA
Inrush current < 30 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22 ... 28 VDC adjustable
Output current Io 5 A at 24 V DC
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 100 mVpp to 20 MHz
Overload behavior Constant power (in overload range:
1.15 ... 1.4 x Ia); shutdown and automatic
restart in the event of a short circuit
Operational indication LED green (24 V DC o.k.),
LED red (overload)
Efficiency / power losses:
Efficiency 82 % typ.
Power loss P
V
19.5 W (at 230 VAC and 5 ADC)
Max. power loss P
V
23.5 W (at 110 VAC and 5.5 ADC)
Fuse protection:
Internal fuse F 5 A / 250 V
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: NTC
Technical Data
Environmental requirements:
Ambient operating temperature -10 C ... +60 C
Storage temperature -25 C ... +85 C
Rel. humidity 95 % (no condensation)
Derating -5.33 % / K (> 45 C at 230 VAC)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 3 kV AC / 1.5 kV AC / 0.5 kV AC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage 28 VDC
Parallel operation yes
Series connection yes
MTBF 480000 h (acc. IEC 61709)
Connection and type of mounting:
Wire connection CAGE CLAMP
ECO Power
L
N
3
DC+
DC+
DC
DC
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
for DIN 35 rail
787-732 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 130 ... 373 VDC
(use of DC requires external protection)
Frequency 47 Hz ... 63 Hz
Input current Ii 1.5 A typ. at 230 VAC;
3.0 A at 115 VAC
Discharge current < 3.5mA
Inrush current < 30 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22 ... 28 VDC adjustable
Output current Io 10 A at 24 V DC
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 100 mVpp to 20 MHz
Overload behavior Constant power (in overload range:
1.15 ... 1.4 x Ia); shutdown and automatic
restart in the event of a short circuit
Operational indication LED green (24 V DC o.k.),
LED red (overload)
Efficiency / power losses:
Efficiency 82 % typ.
Power loss P
V
37.5 W (at 230 VAC and 10 ADC)
Max. power loss P
V
53 W (at 110 VAC and 11 ADC)
Fuse protection:
Internal fuse F 5 A / 250 V
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: NTC
Technical Data
Environmental requirements:
Ambient operating temperature -10 C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 95 % (no condensation)
Derating -2.33 % / K (> 55 C at 230 VAC)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 3 kV AC / 1.5 kV AC / 0.5 kV AC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage 28 VDC
Parallel operation yes
Series connection yes
MTBF 480000 h (acc. IEC 61709)
Connection and type of mounting:
Wire connection CAGE CLAMP
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 V DC / 6 A
787-819 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Input voltage derating -5 % / V AC < 95 VAC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.51 A at 230 VAC and 6 ADC
Discharge current 1 mA typ.
Inrush current < 30 A (peak)
Mains failure hold-up time 70 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC, SELV
Output voltage range 11 ... 18 VDC adjustable
Output current Io 6 A at 12 V DC
PowerBoost 12 ADC (for 4 s); 9 ADC (for 8 s)
TopBoost 21 ADC (for 25 ms)
Factory preset 12 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 83 % typ.
Power loss P
V
0.5 W (stand-by) / 3.0 W (no load) /
9.4 W (rated load)
Fuse protection:
Internal fuse 2 AT
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 25 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 40 x 163 x 163
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 800 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950,
UL 508
787-821
4
294
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 V DC / 10 A
787-821 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Input voltage derating -5 % / V AC < 95 VAC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.97 A at 230 VAC and 10 ADC
Discharge current 1 mA typ.
Inrush current < 30 A (peak)
Mains failure hold-up time 35 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC, SELV
Output voltage range 11 ... 18 VDC adjustable
Output current Io 10 A at 12 V DC
PowerBoost 20 ADC (for 4 s); 15 ADC (for 8 s)
TopBoost 60 ADC (for 25 ms);
40 ADC at V
IN
< 110 VAC (for 25 ms)
Factory preset 12 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 87.8 % typ.
Power loss P
V
0.5 W (stand-by) / 5.0 W (no load) /
14.6 W (rated load)
Fuse protection:
Internal fuse 4 AT
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 25 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 57 x 163 x 163
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 1295 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950,
UL 508
787-831
4
295
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 V DC / 15 A
787-831 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Input voltage derating -1.5 % / V AC < 110 VAC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.9 A at 230 VAC and 15 ADC
Discharge current 1 mA typ.
Inrush current < 8 A (active inrush current limitation)
Mains failure hold-up time 30 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC, SELV
Output voltage range 11 ... 18 VDC adjustable
Output current Io 15 A at 12 VDC
PowerBoost 30 ADC (for 4 s); 22.5 ADC (for 8 s)
TopBoost 55 ADC (for 25 ms)
Factory preset 12 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 87 % typ.
Power loss P
V
0.8 W (stand-by) / 4.6 W (no load) /
23.4 W (rated load)
Fuse protection:
Internal fuse 6.3 AT
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 25 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 57 x 163 x 179
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 1480 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950,
UL 508
787-818
4
296
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 3 A
787-818 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Input voltage derating -5 % / V AC < 95 VAC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.51 A at 230 VAC and 3 ADC
Discharge current 1 mA typ.
Inrush current < 30 A (peak)
Mains failure hold-up time 70 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22 ... 29.5 VDC adjustable
Output current Io 3 A at 24 VDC
PowerBoost 6 ADC (for 4 s); 4.5A DC(for 8 s)
TopBoost 14 A DC (for 25 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 87.8 % typ.
Power loss P
V
0.5 W (stand-by) / 3.0 W (no load) /
8.8 W (rated load)
Fuse protection:
Internal fuse 2 AT
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 40 x 163 x 163
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 960 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950,
UL 508
787-822
4
297
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 5 A
787-822 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Frequency 44 Hz ... 66 Hz
Input current Ii 0.97 A at 230 VAC and 5 ADC
Discharge current 1 mA typ.
Inrush current < 15 A
Mains failure hold-up time 35 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22... 29.5 VDC adjustable
Output current Io 5 A at 24 VDC
PowerBoost 10 ADC(for 4 sec.);
7.5 ADC (for another 2 sec.)
TopBoost 21 ADC (for 25 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 87.8 % typ.
Power loss P
V
0.5 W (stand-by) / 5.0 W (no load) /
14.6 W (rated load)
Fuse protection:
Internal fuse 4 AT
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -25C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -2.5 % / K (> 55 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 57 x 163 x 163
Height from upper-edge of DIN 35 rail
Weight 1268 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950,
UL 508
787-832
4
298
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 10 A
787-832 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Frequency 44 Hz ... 66 Hz
Input current Ii 1.2 A at 230 VAC and 10 ADC
Discharge current 1mA typ.
Inrush current Ie (active inrush current limitation)
Mains failure hold-up time 24 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22... 29.5 VDC adjustable
Output current Io 10 A at 24 V DC
PowerBoost 20 ADC(for 4 sec.);
15 ADC (for another 2 sec.)
TopBoost 60 ADC (for 25 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 91.8 % typ.
Power loss P
V
0.8 W (stand-by) / 3.5 W (no load) /
19.7 W (rated load)
Fuse protection:
Internal fuse 6.3 AT
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -25C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -2.5 % / K (> 55 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 57 x 163 x 179
Height from upper-edge of DIN 35 rail
Weight 1485 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950,
UL 508
787-834
4
299
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 20 A
787-834 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Input voltage derating -1.5 % / V AC < 110 VAC
Frequency 50 Hz ... 60 Hz
Input current Ii 2.3 A at 230 VAC and 20 ADC
Discharge current 1 mA typ.
Inrush current < 8 A (active inrush current limitation)
Mains failure hold-up time 25 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22 ... 29.5 VDC adjustable
Output current Io 20 A at 24 V DC
PowerBoost 30 ADC (for 4 s); 25 ADC (for 8 s)
TopBoost 80 ADC (for 25 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 91 % typ.
Power loss P
V
0.8 W (stand-by) / 4.8 W (no load) /
50.2 W (rated load)
Fuse protection:
Internal fuse 10 AT
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Signalising: WAGO 733 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 97 x 171 x 187
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 2300 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950*,
UL 508* (* pending)
787-833
4
300
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
48 V DC / 5 A
787-833 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Input voltage derating -1.5 % / V AC < 110 VAC
Frequency 50 Hz ... 60 Hz
Input current Ii 1.2 A at 230 VAC and 5 ADC
Discharge current 1 mA typ.
Inrush current < 8 A (active inrush current limitation)
Mains failure hold-up time 20 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 48 VDC, SELV
Output voltage range 33 ... 52 VDC adjustable
Output current Io 5 A at 48 V DC
PowerBoost 10 ADC (for 4 s); 7.5 ADC (for 8 s)
TopBoost 30 ADC (for 25 ms)
Factory preset 48 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 91 % typ.
Power loss P
V
0.8 W (stand-by) / 7.4 W (no load) /
21.6 W (rated load)
Fuse protection:
Internal fuse 6.3 AT
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 63 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 57 x 163 x 179
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 1475 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-835
4
301
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L
N
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
48 V DC / 10 A
787-835 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC
Input voltage range 85 ... 264 VAC; 120 ... 350 VDC
(use of DC requires external protection)
Input voltage derating -1.5 % / V AC < 110 VAC
Frequency 50 Hz ... 60 Hz
Input current Ii 2.3 A at 230 VAC and 10 ADC
Discharge current 1 mA typ.
Inrush current < 8 A (active inrush current limitation)
Mains failure hold-up time 20 ms typ. at 230 VAC
Output:
Nominal output voltage Vo nom 48 VDC, SELV
Output voltage range 33 ... 52 VDC adjustable
Output current Io 10 A at 48 V DC
PowerBoost 17.5 ADC (for 4 s); 15 ADC (for 8 s)
TopBoost 60 ADC (for 25 ms)
Factory preset 48 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Signaling Relay contact DC O.K. (changeover
contact)
Efficiency / power losses:
Efficiency 91 % typ.
Power loss P
V
0.8 W (stand-by) / 4.8 W (no load) /
43.2 W (rated load)
Fuse protection:
Internal fuse 10 AT
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 63 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Signalising: WAGO 733 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 97 x 171 x 187
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 2460 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950*,
UL 508* (* pending)
787-840
4
302
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 10 A
787-840 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
(use of DC requires external protection)
Frequency 50 - 60 Hz
Input current Ii 3 x 0.6 A at 340 VAC and 10 ADC
Discharge current 1mA typ.
Inrush current < 30 A
Mains failure hold-up time 22 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22.8 ... 28.8 VDC adjustable
Output current Io 10 A at 24 V DC
PowerBoost 20 ADC (for 4 s); 15 ADC (for 16 s)
TopBoost 70 ADC (for 50 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Vo), LED red (error)
Efficiency / power losses:
Efficiency 91.7 % typ.
Power loss P
V
7.9 W (stand-by) / 19.9 W (rated load)
Fuse protection:
Internal fuse 3 x 1.6 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 1.6 A, setting range: 1.6 ... 2.5 A
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Cross sections Input/Output:
0.08 ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 57 x 163 x 179
Height from upper-edge of DIN 35 rail
Weight 1000 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-842
4
303
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 20 A
787-842 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
(use of DC requires external protection)
Frequency 50 - 60 Hz
Input current Ii 3 x 1.0 A at 340 VAC and 20 ADC
Discharge current 1mA typ.
Inrush current < 30 A
Mains failure hold-up time 13 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22.8 ... 28.8 VDC adjustable
Output current Io 20 A at 24 VDC
PowerBoost 40 ADC (for 4 s); 30 ADC (for 16 s)
TopBoost 80 ADC (for 50 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Vo), LED red (error)
Efficiency / power losses:
Efficiency 92.9 % typ.
Power loss P
V
8.3 W (stand-by) / 34.1 W (rated load)
Fuse protection:
Internal fuse 3 x 2.5 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 2.5 A, setting range: 2.5 ... 4.0 A
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 77 x 171 x 179
Height from upper-edge of DIN 35 rail
Weight 1300 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-844
4
304
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 40 A
787-844 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
(use of DC requires external protection)
Frequency 50 - 60 Hz
Input current Ii 3 x 2.0 A at 340 VAC and 40 ADC
Discharge current 1 mA typ.
Inrush current < 30 A
Mains failure hold-up time 15 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22.8 ... 28.8 VDC adjustable
Output current Io 40 A at 24 VDC
PowerBoost 60 ADC (for 4 s); 50 ADC (for 16 s)
TopBoost 100 ADC (for 50 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior Constant current
Operational indication LED green (Vo), LED red (error)
Efficiency / power losses:
Efficiency 93.6 % typ.
Power loss P
V
7.0 W (stand-by) / 61.5 W (rated load)
Fuse protection:
Internal fuse 3 x 3.2 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 3.2 A, setting range: 2.5 ... 4.0 A
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -5 % / K ( 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 128 x 171 x 205
Height from upper-edge of DIN 35 rail
Weight 2500 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-845
4
305
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
48 V DC / 10 A
787-845 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 3 x 1.1 A at 340 VAC and 10 ADC
Discharge current 1 mA typ.
Inrush current < 30 A (peak)
Mains failure hold-up time 12 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 48 VDC, SELV
Output voltage range 39 ... 53 VDC adjustable
Output current Io 10 A at 48 VDC
PowerBoost 15 ADC (for 4 s); 12.5 ADC (for 16 s)
TopBoost 55 ADC (for 50 ms)
Factory preset 48 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Efficiency / power losses:
Efficiency 93 % typ.
Power loss P
V
0.8 W (stand-by) / 8.2 W (no load) /
38 W (rated load)
Fuse protection:
Internal fuse 3 x 3.2 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 2.5 A, setting range: 2.5 ... 4.0 A
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 63 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Signalising: WAGO 733 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 77 x 171 x 179
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 1900 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3, UL 60950*,
UL 508* (* pending)
787-847
4
306
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
DC O.K.
Stand-by
Primary switch mode power supply with PowerBoost and TopBoost
Stand-by input for switching off the output and minimizing power
consumption
DC OK contact for output monitoring
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
48 V DC / 20 A
787-847 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 3 x 2.0 A at 340 VAC and 20 ADC
Discharge current 1 mA typ.
Inrush current < 30 A (peak)
Mains failure hold-up time 15 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 48 VDC, SELV
Output voltage range 39 ... 53 VDC adjustable
Output current Io 20 A at 48 VDC
PowerBoost 30 ADC (for 4 s); 25 ADC (for 16 s)
TopBoost 80 ADC (for 25 ms)
Factory preset 48 VDC
Adjustment accuracy 1 %
Residual ripple < 70 mV (peak-peak)
Current limitation 1.1 x Io typ.
Overload behavior TopBoost / PowerBoost /Constant current
Operational indication LED green (Vo), LED red (error)
Efficiency / power losses:
Efficiency 94.4 % typ.
Power loss P
V
0.8 W (stand-by) / 5.2 W (no load) /
59.2 W (rated load)
Fuse protection:
Internal fuse 3 x 3.2 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 3.2 A, setting range: 2.5 ... 4.0 A
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -5 % / K (> +45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 (acc. to EN 60529)
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 63 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Signalising: WAGO 733 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 128 x 171 x 205
(incl. female connector)
Length from upper-edge of DIN 35 rail
Weight 3270 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-850
4
307
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
Primary switch mode power supply with PowerBoost and TopBoost
LineMonitor for parameter setting and monitoring
RS-232 serial interface
4 signal outputs
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 10 A
787-850 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
(use of DC requires external protection)
Frequency 50 - 60 Hz
Input current Ii 3 x 0.6 A at 340 VAC and 10 ADC
Discharge current 1 mA typ.
Inrush current < 30 A
Mains failure hold-up time 22 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22.8 ... 28.8 VDC adjustable
Output current Io 10 A at 24 VDC
PowerBoost 20 ADC (for 4 s); 15 ADC (for 16 s)
TopBoost 70 ADC (for 50 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior adjustable (constant current / fuse mode)
Operational indication LED green (Vo), LED yellow (warning),
LED red (error)
Signaling LED, LCD, 4 x signal output 24 V DC,
25 mA
LineMonitor, parameter setting via LCD and RS-232 serial interface
Efficiency / power losses:
Efficiency 91.7 % typ.
Power loss P
V
7.8 W (stand-by) / 19.9 W (rated load)
Fuse protection:
Internal fuse 3 x 1.6 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 1.6 A, setting range: 1.6 ... 2.5 A
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 231 Series
Signalising: WAGO 733 Series
Cross sections Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input/Output: 8 ... 9 mm / 0.33 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 57 x 163 x 179
Height from upper-edge of DIN 35 rail
Weight 1000 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-852
4
308
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
Primary switch mode power supply with PowerBoost and TopBoost
LineMonitor for parameter setting and monitoring
RS-232 serial interface
4 signal outputs
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 20 A
787-852 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
(use of DC requires external protection)
Frequency 50 - 60 Hz
Input current Ii 3 x 1.0 A at 340 VAC and 20 ADC
Discharge current 1mA typ.
Inrush current < 30 A
Mains failure hold-up time 13 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22.8 ... 28.8 VDC adjustable
Output current Io 20 A at 24 VDC
PowerBoost 40 ADC (for 4 s); 30 ADC (for 16 s)
TopBoost 80 ADC (for 50 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior adjustable (constant current / fuse mode)
Operational indication LED green (Vo), LED yellow (warning),
LED red (error)
Signaling LED, LCD, 4 x signal output 24 V DC,
25 mA
LineMonitor, parameter setting via LCD and RS-232 serial interface
Efficiency / power losses:
Efficiency 92.9 % typ.
Power loss P
V
8.3 W (stand-by) / 34.1 W (rated load)
Fuse protection:
Internal fuse 3 x 2.5 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 2.5 A, setting range: 2.5 ... 4.0 A
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Signalising: WAGO 733 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 77 x 171 x 179
Height from upper-edge of DIN 35 rail
Weight 1300 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-854
4
309
4
Switched-Mode Power Supply
EPSITRON
PRO Power
L1
L2
L3
DC+
DC+
DC -
DC -
Primary switch mode power supply with PowerBoost and TopBoost
LineMonitor for parameter setting and monitoring
RS-232 serial interface
4 signal outputs
Parallel operation, series connection possible
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 40 A
787-854 1
Technical Data
Input:
Nominal input voltage Vi nom 3x (2x) 400 ... 500 VAC
Input voltage range 340 ... 550 VAC; 480 ... 780 VDC
(use of DC requires external protection)
Frequency 50 - 60 Hz
Input current Ii 2.0 A at 340 VAC
Discharge current 1mA typ.
Inrush current < 30 A
Mains failure hold-up time 15 ms typ. at 3 x 400 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22.8 ... 28.8 VDC adjustable
Output current Io 40 A at 24 VDC
PowerBoost 60 ADC (for 4 s); 50 ADC (for 16 s)
TopBoost 100 ADC (for 50 ms)
Factory preset 24 VDC
Adjustment accuracy 1 %
Residual ripple < 70mVpp
Current limitation 1.1 x Io typ.
Overload behavior adjustable (constant current / fuse mode)
Operational indication LED green (Vo), LED yellow (warning),
LED red (error)
Signaling LED, LCD, 4 x signal output 24 V DC,
25 mA
LineMonitor, parameter setting via LCD and RS-232 serial interface
Efficiency / power losses:
Efficiency 93.6 % typ.
Power loss P
V
7.0 W (stand-by) / 61.5 W (rated load)
Fuse protection:
Internal fuse 3 x 3.2 AT
External fuse 3 x circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C;
or motor circuit breakers,
setpoint: 3.2 A, setting range: 2.5 ... 4.0 A
An external DC fuse is required for the DC
input voltage
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +55 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -5 % / K (> 45 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection via varistor at primary circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 35 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection Input: WAGO 231 Series
Output: WAGO 831 Series
Signalising: WAGO 733 Series
Cross sections Input:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Signalising:
0.08 mm ... 0.5 mm / AWG 28 ... 20
Strip lengths Input: 8 ... 9 mm / 0.33 in
Output: 13 ... 15 mm / 0.55 in
Signalising: 5 ... 6 mm / 0.22 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 128 x 171 x 205
Height from upper-edge of DIN 35 rail
Weight 2300 g
Standards and approvals:
Standards/Specifications EN 60950, EN 61204-3,
UL 60950, UL 508
787-601
4
310
Switched-Mode Power Supply
EPSITRON
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 V DC / 2 A
787-601 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.3 A typ. at 230 VAC
Discharge current 900 A typ.
Inrush current < 25 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC, SELV
Output voltage range 11 ... 15 VDC adjustable
Output current Io 2 A at 12 VDC
Factory preset 12 VDC
Adjustment accuracy 3 %
Residual ripple < 100 mVpp to 20 MHz
Current limitation from approx. 1.5 x Io
Overload behavior Hiccup
Operational indication LED green (12 V o.k.)
Efficiency / power losses:
Efficiency 80 % typ.
Power loss P
V
4.8 W typ. (230 VAC / 12 VDC, 2 A)
Max. power loss P
V
5.7 W typ. (90 VAC / 12 VDC 2 A)
Fuse protection:
Internal fuse 2 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 24 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes ("hiccup")
No-load proof yes
Feedback voltage max. 20 VDC
Parallel operation no
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
prepared for class I equipment
parallel operation, series connection possible
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 V DC / 4 A
787-611 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.5 A typ. at 230 VAC
Discharge current 700 A typ.
Inrush current < 30 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC, SELV
Output voltage range 11 ... 15 VDC adjustable
Output current Io 4 A at 12 VDC
Factory preset 12 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp to 20 MHz
Current limitation from approx. 1.1 x Io
Overload behavior Constant current
Operational indication LED green (12 V o.k.)
Efficiency / power losses:
Efficiency 85 % typ.
Power loss P
V
7.6 W typ. (230 VAC / 12 VDC, 4 A)
Max. power loss P
V
8.4 W typ. (90 VAC / 12 VDC 4 A)
Fuse protection:
Internal fuse 4 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> 50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 40 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 20 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
prepared for class I equipment
parallel operation, series connection possible
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
12 V DC / 8 A
787-621 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.8 A typ. at 230 VAC
Discharge current 550 A typ.
Inrush current < 50 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 12 VDC, SELV
Output voltage range 11 ... 15 VDC adjustable
Output current Io 8 A at 12 VDC
Factory preset 12 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp to 20 MHz
Current limitation from approx. 1.1 x Io
Overload behavior Constant current
Operational indication LED green (12 V o.k.)
Efficiency / power losses:
Efficiency 87 % typ.
Power loss P
V
12 W typ. (230 VAC / 12 VDC, 8 A)
Max. power loss P
V
17 W typ. (90 VAC / 12 VDC 8 A)
Fuse protection:
Internal fuse 4 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 24 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 20 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 1.3 A
787-602 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.3 A typ. at 230 VAC
Discharge current 900 A typ.
Inrush current < 25 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22 ... 28.8 VDC adjustable
Output current Io 1.3 A at 24 VDC
Factory preset 24 VDC
Adjustment accuracy 3 %
Residual ripple < 100 mVpp to 20 MHz
Current limitation from approx. 1.5 x Io
Overload behavior Hiccup
Operational indication LED green (24 V o.k.)
Efficiency / power losses:
Efficiency 83 % typ.
Power loss P
V
4.9 W typ. (230 VAC / 24 VDC, 1.3 A)
Max. power loss P
V
7 W typ. (90 VAC / 24 VDC 1.3 A)
Fuse protection:
Internal fuse 2 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 40 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes ("hiccup")
No-load proof yes
Feedback voltage max. 30 VDC
Parallel operation no
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
prepared for class I equipment
parallel operation, series connection possible
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 2.5 A
787-612 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.6 A typ. at 230 VAC
Discharge current 700 A typ.
Inrush current < 50 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22 ... 28.8 VDC adjustable
Output current Io 2.5 A at 24 VDC
Factory preset 24 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp to 20 MHz
Current limitation from approx. 1.1 x Io
Overload behavior Constant current
Operational indication LED green (24 V o.k.)
Efficiency / power losses:
Efficiency 90 % typ.
Power loss P
V
7 W typ. (230 VAC / 24 VDC, 2.5 A)
Max. power loss P
V
8 W typ. (90 VAC / 24 VDC 2.5 A)
Fuse protection:
Internal fuse 1.6 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>55 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 40 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 30 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
prepared for class I equipment
parallel operation, series connection possible
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
24 V DC / 5 A
787-622 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.85 A typ. at 230 VAC
Discharge current 550 A typ.
Inrush current < 30 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 V DC, SELV
Output voltage range 22 ... 28.8 VDC adjustable
Output current Io 5 A at 24 VDC
Factory preset 24 VDC
Adjustment accuracy 2 %
Residual ripple < 100 mVpp to 20 MHz
Current limitation from approx. 1.1 x Io
Overload behavior Constant current
Operational indication LED green (24 V o.k.)
Efficiency / power losses:
Efficiency 90 % typ.
Power loss P
V
10 W typ. (230 VAC / 24 VDC, 5 A)
Max. power loss P
V
13 W typ. ( 90 VAC / 24 VDC 5 A)
Fuse protection:
Internal fuse 4 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>55 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 40 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 30 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
prepared for class I equipment
parallel operation, series connection possible
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,,
24 V DC / 10 A
787-632 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 230 VAC; 100 ... 300 VDC
Input voltage range 85 ... 264 VAC; 90 ... 350 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 2 A typ. at 230 VAC
Discharge current 1 mA typ.
Inrush current < 60 Ap
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 24 VDC, SELV
Output voltage range 22.8 ... 28.8 VDC adjustable
Output current Io 10 A at 24 VDC
Factory preset 24 VDC
Adjustment accuracy 3 %
Residual ripple < 200 mVpp at 20 MHz
Current limitation from 1.2 x Ia
Overload behavior Constant current
Operational indication LED green (24 V o.k.), LED red (overload)
Efficiency / power losses:
Efficiency 88% typ.
Power loss P
V
26.9 W typ. (230 VAC / 24 VDC, 10 A)
Max. power loss P
V
32.6 W typ. (90 VAC / 24 VDC 10 A)
Fuse protection:
Internal fuse 6.3 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>50 C); -2 % / K (Ve < 97 VAC)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 33 VDC
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 33 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
thermal overload protection
parallel operation, series connection possible
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
48 V DC / 1 A
787-613 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 0.6 A typ. at 230 VAC
Discharge current 1 mA typ.
Inrush current < 50 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 48 VDC, SELV
Output voltage range 43.2 ... 52.8 VDC adjustable
Output current Io 1 A at 48 VDC
Factory preset 48 VDC
Adjustment accuracy 2 %
Residual ripple < 200 mVpp at 20 MHz
Current limitation from 1.1 x Ia
Overload behavior Constant current
Operational indication LED green (48 V o.k.)
Efficiency / power losses:
Efficiency 86 % typ.
Power loss P
V
7 W typ. (230 VAC / 48 VDC, 1 A)
Max. power loss P
V
7.8 W typ. (264 VAC / 48 VDC 1 A)
Fuse protection:
Internal fuse 1.6 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>60 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 65 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 56 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
thermal overload protection
parallel operation, series connection possible
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
48 V DC / 2 A
787-623 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC; 140 ... 300 VDC
Input voltage range 90 ... 264 VAC; 130 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 1.2 A typ. at 230 VAC
Discharge current 550 A typ.
Inrush current < 50 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 48 VDC, SELV
Output voltage range 42 ... 52.8 VDC adjustable
Output current Io 2 A at 48 VDC
Factory preset 48 VDC
Adjustment accuracy 2 %
Residual ripple < 200 mVpp at 20 MHz
Current limitation from 1.1 x Ia
Overload behavior Constant current
Operational indication LED green (48 V o.k.)
Efficiency / power losses:
Efficiency 90% typ.
Power loss P
V
8.8 W typ. (230 VAC / 48 VDC, 2 A)
Max. power loss P
V
11.4 W typ. (90 VAC / 48 VDC 2 A)
Fuse protection:
Internal fuse 4 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>55 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 65 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 56 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
DC+
DC+
DC -
DC -
thermal overload protection
parallel operation, series connection possible
prepared for class I equipment
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
48 V DC / 5 A
787-633 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC; 140 ... 300 VDC
Input voltage range 85 ... 264 VAC; 90 ... 350 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 2.8 A typ. at 230 VAC
Discharge current 1 mA typ.
Inrush current < 60 A
Mains failure hold-up time > 20 ms at 230 VAC
Output:
Nominal output voltage Vo nom 48 VDC
Output voltage range 43.2 ... 52.8 VDC adjustable
Output current Io 5 A at 48 VDC
Factory preset 48 VDC
Adjustment accuracy 3 %
Residual ripple < 100 mVpp at 20 MHz
Current limitation from 1.1 x Ia
Overload behavior Constant current
Operational indication LED green (48 V o.k.), LED red (overload)
Efficiency / power losses:
Efficiency 89% typ.
Power loss P
V
25.9 W typ. (230 VAC / 48 VDC, 5 A)
Max. power loss P
V
31.2 W typ. (90 VAC / 48 VDC 5 A)
Fuse protection:
Internal fuse 6.3 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>50 C); -2 % / K (Ve < 97 VAC)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 58 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 56 VDC
Parallel operation yes
Series connection yes
Connection and type of mounting:
Wire connection CAGE CLAMP
CLASSIC Power
L
N
ASI+
ASI -
min. cond. cross section acc. to AS-Interface specification: 1.5 mm
2
natural convection cooling when horizontally mounted
encapsulated, for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
for DIN 35 rail
787-692 1
Technical Data
Input:
Nominal input voltage Vi nom 110 ... 240 VAC; 140 ... 300 VDC
Input voltage range (85) 97 ... 264 VAC /
(120) 140 ... 300 VDC
Frequency 50 Hz ... 60 Hz
Input current Ii 1.4 A at 115 VAC / 0.8 A at 230 VAC
Discharge current 600 A typ.
Inrush current < 50 A
Mains failure hold-up time > 50 ms at 230 VAC
Output:
Nominal output voltage Vo nom 30.5 VDC, SELV
Output voltage range 26 ... 33 VDC adjustable
Output current Io 3 A at 30.5 VDC
Factory preset 30.5 VDC
Adjustment accuracy 3 %
Residual ripple < 300 mVpp (< 10 kHz) /
< 50 mVpp (10 kHz ... 20 MHz)
Current limitation from 1.1 x Ia
Overload behavior Constant current
Operational indication LED green (operating condition at Vo)
Efficiency / power losses:
Efficiency 89 % typ.
Power loss P
V
9 W typ. (230 VAC / 30.5 VDC, 3 A)
Max. power loss P
V
14.2 W typ. (264 VAC / 30.5 VDC 3 A)
Fuse protection:
Internal fuse 4 AT / 250 VAC
External fuse C10 or B16 circuit breakers
An external DC fuse is required for the DC
input voltage
Transient overvoltage protection: Varistor
Technical Data
Environmental requirements:
Ambient operating temperature -10C ... +70C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (>55 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class Prepared for class I equipment
Degree of protection IP20 acc. to EN 60529
Overvoltage protection max. 48 VDC (output)
Overload protection via thermal protective circuit
Short circuit protection yes
No-load proof yes
Feedback voltage max. 40 VDC
Parallel operation no
Series connection no
Connection and type of mounting:
Wire connection CAGE CLAMP
L
N
3
DC+ DC TEMP REMOTE
DC+
DC+
DC
DC
ACCU
IN OUT
Primary switch mode power supply with integrated charger and controller for
uninterruptible power supply (UPS)
Battery control technology for smooth charging and predictive maintenance
applications
Potential-free contacts provide function monitoring
Buffer time can be set on-site via rotary switch
Parameter setting and monitoring via RS-232 interface
Prepared for class I equipment
Natural convection cooling when horizontally mounted
Enclosed for use in switchgear cabinets
Description Item No.
Pack.
Unit
Switched-Mode Power Supply,
with Integrated UPS Charger and
Controller, 24VDC / 5A
787-1675 1
Technical Data
Input:
Nominal input voltage Vi nom 100 ... 240 VAC; 110 ... 370 VDC
Input voltage range 85 V ... 264 V AC
Frequency 45 Hz ... 65 Hz; 0 Hz
Input current Ii 1,1 A at 230 VAC and 5 ADC
Inrush current < 30 A
Output:
Nominal output voltage Vo nom 24 VDC
Output voltage range 23.0 28.5 VDC (mains operation)
18.5 27.5 VDC (battery operation)
Output current Io 5 A
Adjustment accuracy 1 %
Residual ripple < 100 mV (peak-peak)
Current limitation 1.1 x Io; TopBoost 24 A
Buffer time 0.5 20 min, IPC mode or constant
(adjustable)
Switch-on threshold (adjustable) 22 VDC (pre-configured),
20 25.5 VDC (configurable via software)
Final load voltage 26 29.5 VDC temperature-controlled
(fixed or adjustable)
Charging current 0.3 A ... 0.6 A
Recommended battery modules 787-876, 787-871, 787-872, 787-873
Operational indication Green LED (DC OK), yellow LED (battery
mode), red LED (warning/fault)
Signaling 3 x 24 VDC signal output, 25 mA and
1 x 30 VDC isolated relay contact, 1 A
Remote input to switch off buffer operation
LineMonitor, parameter setting via RS-232 serial interface
Efficiency / power losses:
Efficiency 89 % typ.
Power loss P
V
4 W (battery operation, 24 VDC, 5 A) /
15 W (mains operation,
240 VAC/24 VDC, 5 A)
Fuse protection:
Internal fuse 4 AT (input side)
External fuse Circuit breakers 6 A, 10 A, 16 A,
characteristic: B or C
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -40 C ... +85 C
Derating -3 % / K (> +50 C)
Degree of pollution 2 (acc. to EN 50178)
Climatic category 3K3 (acc. to EN 60721)
Safety and protection:
Test voltage pri.-sec./ pri.-gr. / sec.-gr. 4.2 kV DC / 2.2 kV DC / 0.7 kV DC
Protection class I
Reverse voltage protection yes
Degree of protection IP20 (acc. to EN 60529)
Feedback voltage max. 35 V DC
Parallel operation yes, max. 3 battery modules for buffer time
extension
Connection and type of mounting:
Wire connection Input/Output/Signals: WAGO 721 Series
Interface: WAGO 733 Series
Cross sections Input/Output/Signals:
0.5 mm ... 10 mm / AWG 20 ... 10
Interface:
0.08 mm ... 2.5 mm / AWG 28 ... 20
Strip lengths Input/Output/Signals:
13 ... 15 mm / 0.55 in
Interface: 8 ... 9 mm / 0.33 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 60 x 127 x 135.5
Length from upper-edge of DIN 35 rail
Weight 440 g
Standards and approvals:
Standards/Specifications EN 60950, UL 60950*, UL 508*,
EN 61000-6-2, EN 61000-6-3
(* pending)
787-870
4
322
EPSITRON
13 14
ON
OUT1 (+) DC 24V (+)
0 V
OUT1 (+)
OUT1 (+)
OUT1 (+)
0 V
2..10A
2..10A
2..10A
2..10A
Compact 4-channel electronic circuit breaker
210 A nominal current, adjustable for each channel via sealable selector
switch
Switch-on capacity > 50000 F per channel
One illuminated bi-color button per channel simplifies switching (on/off),
resetting and on-site diagnosing
Time-delayed switching of channels
24 VDC output as group message (triggered channel)
24 VDC output as channel status message (pulse sequence)
Remote input resets tripped channels or switching on/off any number of
channels via pulse sequence
Description Item No.
Pack.
Unit
Electronic Circuit Breaker,
24 VDC / 4 x 10 A
787-1664 1
Technical Data
Input:
Nominal input voltage Vi nom 24 V DC
Input voltage range 18 ... 30 V DC
Output:
Nominal output voltage Vo nom 4 x 24 V DC
Nominal current max. 4 x 10 ADC
(2, 3, 4, 6, 8, 10 A adjustable for each
channel via selector switch)
Voltage drop 200 mV at 10 A
Trip time Load-dependent (20 ms 100 s)
Switch-on capacity > 50000 F per channel
Switch-on behavior Time-delayed channel switching
(50 100 ms each)
Operational indication Green LED (channel OK),
Red LED (channel triggered)
Signaling 4 x LED (green/red), 1 x 24 VDC group
message , 1 x 24 VDC status message
(pulse sequence)
Remote input Reactivation of all tripped channels via
15 30 VDC pulse for min. 500 ms.
Switching on/off any number of channels
via pulse sequence.
Efficiency / power losses:
Efficiency 99 % typ.
Power loss P
V
1.3 W (stand-by) / 20 W (nominal load)
Fuse protection:
Internal fuse 15 AT per channel
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Safety and protection:
Test voltage 500 V DC (terminals to enclosure)
Protection class III
Reverse voltage protection no
Degree of protection IP20 (acc. to EN 60529)
Overload protection via 33 V suppressor diode at input
Feedback voltage max. 35 VDC
Series connection of several devices not permitted
Parallel operation of single channels not permitted
Connection and type of mounting:
Wire connection Input: WAGO 831 Series
Input/Output: WAGO 721 Series
Cross sections Input:
0.5 mm ... 10 mm / AWG 20 ... 8
Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Strip lengths Input: 13 ... 15 mm / 0.55 in
Input/Output: 8 ... 9 mm / 0.33 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 45 x 90 x 115.5
Length from upper-edge of DIN 35 rail
Weight 170 g
Standards and approvals:
Standards/Specifications UL 60950*, UL 508*, UL 2367*, GL*,
EN 60950, EN 61000-6-2,
EN 61000-6-3 (* pending)
787-1668
4
332
Electronic Circuit Breaker
EPSITRON
13 14
ON
OUT1 (+) DC 24V (+)
0 V
OUT2 (+)
OUT3 (+)
OUT4 (+)
0 V
2..10A
2..10A
2..10A
2..10A
OUT5 (+)
OUT6 (+)
OUT7 (+)
OUT8 (+)
2..10A
2..10A
2..10A
2..10A
Compact 8-channel electronic circuit breaker
210 A nominal current, adjustable for each channel via sealable selector
switch
Switch-on capacity > 50000 F per channel
One illuminated bi-color button per channel simplifies switching (on/off), re-
setting and on-site diagnosing
Time-delayed switching of channels
24 VDC output as group message (triggered channel)
24 VDC output as channel status message (pulse sequence)
Remote input resets tripped channels or switching on/off any number of
channels via pulse sequence
Description Item No.
Pack.
Unit
Electronic Circuit Breaker,
24 VDC / 8 x 10 A
787-1668 1
Technical Data
Input:
Nominal input voltage Vi nom 24 V DC
Input voltage range 18 ... 30 V DC
Output:
Nominal output voltage Vo nom 8x 24 V DC
Nominal current max. 8 x 10 ADC
(2, 3, 4, 6, 8, 10 A adjustable for each
channel via selector switch)
Voltage drop 200 mV at 10 A
Trip time Load-dependent (20 ms 100 s)
Switch-on capacity > 50000 F per channel
Switch-on behavior Time-delayed channel switching
(50 100 ms each)
Operational indication Green LED (channel OK),
Red LED (channel triggered)
Signaling 8 x LED (green/red), 1 x 24 VDC group
message , 1 x 24 VDC status message
(pulse sequence)
Remote input Reactivation of all tripped channels via
15 30 VDC pulse for min. 500 ms.
Switching on/off any number of channels
via pulse sequence.
Efficiency / power losses:
Efficiency 99 % typ.
Power loss P
V
1.3 W (stand-by) / 20 W (nominal load)
Fuse protection:
Internal fuse 15 AT per channel
Technical Data
Environmental requirements:
Ambient operating temperature -25 C ... +70 C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Derating -3 % / K (> +50 C)
Safety and protection:
Test voltage 500 V DC (terminals to enclosure)
Protection class III
Reverse voltage protection no
Degree of protection IP20 (acc. to EN 60529)
Overload protection via 33 V suppressor diode at input
Feedback voltage max. 35 VDC
Series connection of several devices not permitted
Parallel operation of single channels not permitted
Connection and type of mounting:
Wire connection Input: WAGO 831 Series
Input/Output: WAGO-Serie 721
Cross sections Input:
0.5 mm ... 10 mm / AWG 20 ... 8
Input/Output:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Strip lengths Input: 13 ... 15 mm / 0.55 in
Input/Output: 8 ... 9 mm / 0.33 in
Type of mounting DIN-rail mount (EN 60715)
Dimensions and weight:
Dimensions (mm) W x H x L 42 x 127 x 142.5
Length from upper-edge of DIN 35 rail
Weight 800 g
Standards and approvals:
Standards/Specifications UL 60950*, UL 508*, UL 2367*, GL*,
EN 60950, EN 61000-6-2,
EN 61000-6-3 (* pending)
4
333
4
787-880
4
334
EPSITRON
- Redundancy Module
IN
1
+
2
OUT
Redundancy module with 2 inputs for decoupling 2 power supplies
For redundant or uninterruptible power supply
With potential-free contact for input voltage monitoring
Description Item No.
Pack.
Unit
Redundancy Module
24 VDC, 2 x 20 A / 1 x 40 A
787-885 1
Technical Data
Input:
Nominal input voltage Vi nom 2 x 24 V DC
Input voltage range 18 V ... 30 V DC
Input current Ii 2 x 20 A, max. 1 x 40 A
Output:
Nominal output voltage Vo nom 24 V DC
Output voltage range Ve - 1 V DC
Output current Io 20 A, max. 40 A
Operational indication LED green (Vo), 2 x LED yellow (Vi)
Signaling 1 x floating relay contact 30 V DC, 1 A
Efficiency / power losses:
Efficiency 97 % typ.
Power loss P
V
1.5 W open circuit
14 W nominal load (20 A) /
26 W nominal load (40 A)
Fuse protection:
Internal fuse no
Technical Data
Environmental requirements:
Ambient operating temperature -10 C ... +60C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Safety and protection:
Test voltage 500 V DC (terminals to enclosure)
Protection class III
Reverse voltage protection yes
Degree of protection IP20 (acc. to EN 60529)
Feedback voltage max. 33 VDC
Parallel operation yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 831 Series
Relay: WAGO 231 Series
Cross sections Input/Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Relay:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output: 13 ... 15 mm / 0.55 in
Relay: 8 ... 9 mm / 0.33 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 40 x 163 x 181
Height from upper-edge of DIN 35 rail,
T=127mm without pluggable female
Weight 870 g
Standards and approvals:
Standards/Specifications EN 60950, UL 60950, UL 508,
EN 61000-6-2, EN 61000-6-3
787-886
4
337
4
EPSITRON
- Redundancy Module
IN
1
+
2
OUT
Redundancy module with 2 inputs for decoupling 2 power supplies
For redundant or uninterruptible power supply
With potential-free contact for input voltage monitoring
Description Item No.
Pack.
Unit
Redundancy Module
48 VDC, 2 x 20 A / 1 x 40 A
787-886 1
Technical Data
Input:
Nominal input voltage Vi nom 2 x 48 V DC
Input voltage range 36 V ... 54 V DC
Input current Ii 2 x 20 A, max. 1 x 40 A
Output:
Nominal output voltage Vo nom 48 V DC
Output voltage range Ve - 1 V DC
Output current Io 20 A, max. 40 A
Operational indication LED green (Vo), 2 x LED yellow (Vi)
Signaling 1 x floating relay contact 30 V DC, 1 A
Efficiency / power losses:
Efficiency 96 % typ.
Power loss P
V
1.7 W (48 VDC/no load) /
20 W (48 VDC/rated load) (20 A) /
40 W (48 VDC/rated load) (40 A)
Fuse protection:
Internal fuse no
Technical Data
Environmental requirements:
Ambient operating temperature -10 C ... +60C
Storage temperature -25 C ... +85 C
Rel. humidity 30 % ... 85 % (no condensation)
Safety and protection:
Test voltage 500 V DC (terminals to enclosure)
Protection class III
Reverse voltage protection yes
Degree of protection IP20 (acc. to EN 60529)
Feedback voltage max. 60 VDC
Parallel operation yes
Connection and type of mounting:
Wire connection Input/Output: WAGO 831 Series
Relay: WAGO 231 Series
Cross sections Input/Output:
0.5 mm ... 10 mm / AWG 20 ... 8
Relay:
0.08 mm ... 2.5 mm / AWG 28 ... 12
Strip lengths Input/Output: 13 ... 15 mm / 0.55 in
Relay: 8 ... 9 mm / 0.33 in
Type of mounting DIN-rail mounting (EN 60715) in
2 positions
Dimensions and weight:
Dimensions (mm) W x H x L 40 x 181 x 163
Length from upper-edge of DIN 35 rail
Weight 860 g
Standards and approvals:
Standards/Specifications EN 60950, UL 60950*, UL 508*,
EN 61000-6-2, EN 61000-6-3
(* pending)
787-890
4
338
EPSITRON - RS-232 Communication Cable
1 2 3 4 5 6 7 8
RxD
PC
Pin 2 = RxD PC
Pin 3 = TxD PC
Pin 5 = GND
TxD
PC
The 787-890 Communication Cable is used for configuration and
visualization via PC or controller.
It is suitable for all 787 Series devices equipped with an RS-232
serial interface.
PC software for 787 Series devices can be downloaded
at: www.wago.com/epsitron
Function blocks for communication with WAGO-I/O-SYSTEM 750
are also available.
NOTE:
The 787-890 Communication Cable is not electrically isolated.
Description Item No.
Pack.
Unit
RS-232 communication cable 787-890 1
Technical Data
Type of signal RS-232
Ports 1 x 8-pole 734-108 Female Connector
with strain relief
(787-8xx Module side),
1x 9-pole SUB-D female connector
(PC/controller side)
Isolation No
Cross sections 3 x 0.34 mm (AWG 22), shielded
Ambient operating temperature -10C ... +70C
Degree of protection IP20
Length 1.8 m
4
339
4
EPSITRON
(236 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN) 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Accessories
WMB Multi marking system for mounting carrier see page 408
Marker strips for mounting carrier white 709-198 / translucent 709-196
U
E
0V
U
A
0V
Constant
voltage source
U
A2
0V
U
A1
~
~
Constant
voltage source
4
343
4
24 VDC; 5 A
Input 24 VAC +10 %
Electronic overload protection
Output voltage indication by LED
Mounting carrier for DIN 35 rail
Description Item No.
Pack.
Unit
Constant voltage source 24 VDC 288-801 1
Technical Data
Input voltage 24 VAC +10%
Output voltage 24 VDC ( 10 %)
Nominal output current 5 A
Overload protection electronic
Voltage returns after removal of overload after 4 s
Ambient operating temperature 0 C ... +30 C
Weight 600.5 g
Dimensions (mm) W x H x L 170 x 85 x 108
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
(236 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in
Accessories
WMB Multi marking system for mounting carrier see page 408
Marker strips for mounting carrier white 709-198 / translucent 709-196
0V
U
A
~
~
Constant
voltage source
with overload
protection
4
344
Rail-Mounted Modules - Power Supplies
115 VAC / 24 VDC; 0.5 A
Output voltage indication by LED
Mounting carrier for DIN 35 rail
230 VAC / 24 VDC; 0.5 A
Output voltage indication by LED
Mounting carrier for DIN 35 rail
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Power supply, with universal mounting carrier 288-809 1 288-810 1
Technical Data
Nominal input voltage Vi nom 115 VAC 230 VAC
Input voltage range 10 % 10 %
Frequency 50 Hz ... 60 Hz 50 Hz ... 60 Hz
Power consumption at nominal load 30 VA 30 VA
Nominal output voltage Vo nom 24 VDC 24 VDC
Output voltage range 4 % 4 %
Output current Io 0.5 A 0.5 A
Residual ripple d 10 mVss d 10 mVss
Output fuse 0.8 A slow 0.8 A slow
Ambient operating temperature 0 C ... +50 C 0 C ... +50 C
Weight 579 g 552 g
Dimensions (mm) W x H x L 77 x 52 x 106 77 x 52 x 106
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
(236 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN) 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals Transformer acc. to VDE 0551 Transformer acc. to VDE 0551
Accessories
WMB Multi marking system for mounting carrier see page 408 see page 408
Marker strips for mounting carrier white 709-198 / translucent 709-196 white 709-198 / translucent 709-196
+
0,8 A T
L
N
regulator
gray
light gray
orange
blue
+
0,8 A T
L
N
regulator
gray
light gray
orange
blue
4
345
4
230 VAC / 12 VDC; 0.5 A
Output voltage indication by LED
Mounting carrier for DIN 35 rail
115 VAC / 24 VDC; 2 A
Output voltage indication by LED
Mounting carrier for DIN 35 rail
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Power supply, with universal mounting carrier 288-808 1 288-813 1
Technical Data
Nominal input voltage Vi nom 230 VAC 115 VAC
Input voltage range 10 % 10 %
Frequency 50 Hz ... 60 Hz 50 Hz ... 60 Hz
Power consumption at nominal load 23 VA 80 VA
Nominal output voltage Vo nom 12 VDC 24 VDC
Output voltage range 4 % 10 %
Output current Io 0.5 A 2 A
Residual ripple d 10 mVss d 80 mVss
Input fuse 0.8 A medium-slow
Output fuse 0.8 A slow electronic, short-circuit protected
Short-circuit current 2.5 A
Ambient operating temperature 0 C ... +50 C 0 C ... +40 C
Weight 574 g 1969 g
Dimensions (mm) W x H x L 77 x 52 x 106 182 x 98 x 106
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
(256 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN) 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals Transformer acc. to VDE 0551 Transformer acc. to VDE 0551
Accessories
WMB Multi marking system for mounting carrier see page 408 see page 408
Marker strips for mounting carrier white 709-198 / translucent 709-196 white 709-198 / translucent 709-196
+
0,8 A T
L
N
regulator
gray
light gray
orange
blue
+
0,5 A MT
L
N
gray
light gray
orange
blue
regulator
4
346
Rail-Mounted Modules - Power Supplies
230 VAC / 24 VDC; 2 A
Output voltage indication by LED
Mounting carrier for DIN 35 rail
230 VAC / 12 VDC; 0.5 A
230 VAC / 15 VDC; 0.5 A
Output voltage indication by LED
Mounting carrier for DIN 35 rail
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
Power supply, with universal mounting carrier 288-812 1 288-814 1
288-815 1
Technical Data
Nominal input voltage Vi nom 230 VAC 230 VAC
Input voltage range 10 % 10 %
Frequency 50 Hz ... 60 Hz 50 Hz ... 60 Hz
Power consumption at nominal load 80 VA 27 VA
Nominal output voltage Vo nom 24 VDC 12 VDC (288-814)
15 VDC (288-815)
Output voltage range 10 % 4 %
Output current Io 2 A 2 x 0.5 A
Residual ripple d 80 mVss d 10 mVss
Input fuse 0.5 A medium-slow
Output fuse electronic, short-circuit protected 2 x 0.8 A slow
Short-circuit current 2.5 A
Ambient operating temperature 0 C ... +40 C 0 C ... +40 C
Weight 1900 g 675 g (288-814)
665 g (288-815)
Dimensions (mm) W x H x L 182 x 98 x 106 94 x 57 x 106
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
(256 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN) 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals Transformer acc. to VDE 0551 Transformer acc. to VDE 0551
Accessories
WMB Multi marking system for mounting carrier see page 408 see page 408
Marker strips for mounting carrier white 709-198 / translucent 709-196 white 709-198 / translucent 709-196
+
0,5 A MT
L
N
gray
light gray
orange
blue
regulator
+
T
L
N
gray
light gray
orange
blue
dark gray
regulator
regulator
4
347
4
230 VAC / 15 VDC;
2 x 1 A short-circuit proof
Output voltage indication by LED
Mounting carrier for DIN 35 rail
Description Item No.
Pack.
Unit
Power supply, with universal mounting carrier 288-816 1
Technical Data
Nominal input voltage Vi nom 230 VAC
Input voltage range 10 %
Frequency 50 Hz ... 60 Hz
Power consumption at nominal load 53 VA
Nominal output voltage Vo nom 15 VDC
Output voltage range 4 %
Output current Io 2 x 1 A
Residual ripple d 10 mVss
Short-circuit current approx. 1.5 A
Ambient operating temperature 0 C ... +40 C
Weight 1011 g
Dimensions (mm) W x H x L 138 x 87 x 106
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
(256 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in
Approvals Transformer acc. to VDE 0551
Accessories
WMB Multi marking system for mounting carrier see page 408
Marker strips for mounting carrier white 709-198 / translucent 709-196
+
T
L
N
gray
light gray
orange
blue
dark gray
regulator
regulator
4
348
Rail-Mounted Terminal Blocks with DC/DC Converter
DC/DC converter
24 V / 5 V, 0.5 ADCADC
DC/DC converter
24 V / 10 V, 0.5 ADC
Description V
N
/ V
O
Item No.
Pack.
Unit
V
N
/ V
O
Item No.
Pack.
Unit
DC/DC converter, for DIN 35 rail 24 VDC / 5 VDC 2 % 859-801 1 24 VDC / 10 VDC 2 % 859-802 1
Technical Data
Nominal input voltage (V
N
) 24 VDC 24 VDC
Input voltage range 10 ... 30 VDC 15 ... 30 VDC
Output voltage 5 VDC 2 % 10 VDC 2 %
Output current (max.) 500 mA 500 mA
Line regulation, max. (full load, over input voltage range) 2 % 0.5 %
Max. load regulation (no load to full load, nominal input 0.5 % 0.7 %
Efficiency at full load (24 VDC in) 70 % 85 %
Output noise peak-to-peak max. (20 MHz bandwidth) 150 mV 20 mV
Switching frequency 200 kHz (nominal) 200 kHz (nominal)
Isolation non-isolated non-isolated
Reverse voltage protection, input yes yes
Minimum load requirement no no
Max. transient recovery time (recovery time for load
change from 25 % to 75% of full load)
40 s 500 s
Max. startup time (24 VDC in, full load) 3 ms 3 ms
Max. hold time (nominal input voltage, full load) 1 ms 500 s
Input fuse TVS diode TVS diode
Output short circuit protection temporary (short-circuit of the output for 1 minute without
damage to the device)
temporary (short-circuit of the output for 1 minute without
damage to the device)
Temperature coefficient 70 ppm/C 100 ppm/C
Ambient operating temperature 0 C ... +40 C -25 C ... +55 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 14 0.08 ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
4
349
4
DC/DC converter
12 V / 24 V, 250 mADC
DC/DC converter
24 V / 12 V, 0.5 ADC
Description V
N
/ V
O
Item No.
Pack.
Unit
V
N
/ V
O
Item No.
Pack.
Unit
DC/DC converter, for DIN 35 rail 12 VDC / 24 VDC 1 % 859-804 1 24 VDC / 12 VDC 2 % 859-805 1
Technical Data
Nominal input voltage (V
N
) 12 VDC 24 VDC
Input voltage range 8 ... 16 VDC 15 ... 30 VDC
Output voltage 24 VDC 1 % 12 VDC 2 %
Output current (max.) 250 mA 500 mA
Line regulation, max. (full load, over input voltage range) 0.5 % 0.5 %
Max. load regulation (no load to full load, nominal input 0.5 % 0.7 %
Efficiency at full load (24 VDC in) 83 % 85 %
Output noise peak-to-peak max. (20 MHz bandwidth) 40 mV 20 mV
Switching frequency 1.2 MHz (nominal) 200 kHz (nominal)
Isolation non-isolated non-isolated
Reverse voltage protection, input yes yes
Minimum load requirement no no
Max. transient recovery time (recovery time for load
change from 25 % to 75% of full load)
50 s 500 s
Max. startup time (24 VDC in, full load) 8 ms 3 ms
Max. hold time (nominal input voltage, full load) 500 s 500 s
Input fuse TVS diode TVS diode
Output short circuit protection fuse temporary (short-circuit of the output for 1 minute without
damage to the device)
Temperature coefficient 100 ppm/C 100 ppm/C
Ambient operating temperature -25 C ... +55 C -25 C ... +55 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 14 0.08 ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
4
350
Rail-Mounted Modules - DC/DC Converter
24 V / 24 V; 0.21 ADC
Mounting feet for DIN 35 rail
24 V / 18 V; 0.4 ADC
Mounting carrier for DIN 35 rail
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
DC/DC converter 289-913 1 288-895 1
Technical Data
Input voltage 24 VDC 24 VDC
Input voltage range 10 % 18 ... 36 VDC
Output voltage 24 VDC ( 3 %) 18 VDC ( 1 %)
Nominal output current 210 mA 400 mA
Peak output current 315 mA
Efficiency 65 % ... 75 % 82 %
Test voltage input/output 500 VDC 1500 VDC
Short circuit protection Thermal cut-out permanent
Ambient operating temperature -25 C ... +40 C -25 C ... +70 C
Weight 77 g 75.9 g
Dimensions (mm) W x H x L 83 x 25 x 77 50 x 25 x 85
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
(256 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN) 0.08 ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
EMC 1-Immunity to interference acc. to EN 50082-2 (1996) * * Only in conjunction with
DALI/DSI Master Module 750-641
EMC 1-Emission of interference acc. to EN 50081-1 (1993) * * Only in conjunction with
DALI/DSI Master Module 750-641
Accessories
WMB Multi marking system for mounting carrier see page 408
Marker strips for mounting carrier white 709-198 / translucent 709-196
O
U
T
O
U
T
O
U
T
+
O
U
T
+
IN
+
IN
O
U
T
+
O
U
T
289-913
288-895
IN
+
IN
+
IN
IN
S
DC
DC
+
DC 24V DC 24V
DC
DC
+
DC 24V DC 18 V
4
351
4
EPSITRON - Back-Up Capacitor Module
Back-up capacitor module
smoothes unstable
24 VDC power supplies
Mounting carrier for DIN 35 rail
This module is equipped with a capacitor which smoothes
unstable 24 VDC power supplies in case the voltage
tolerances mentioned in our data sheets cannot be
ensured. Reasons for voltage transients could be:
Voltage disconnections (switching transients) on primary
side
Overloads on secondary side
Switching of inductive or capacitive loads
The back-up capacitor module is connected between the
24 V power supply and the electronic device which has to
be protected.
Notice:
If using a non-filtered single-phase power supply, the
capacitor causes a voltage increase.
Description Item No.
Pack.
Unit
Back-up capacitor module 288-824 1
Technical Data
Nominal voltage 24 VDC (+25 %)
Nominal current 1 A
Nominal capacity 10000 F
Weight 104.4 g
Dimensions (mm) W x H x L 38 x 81 x 85
Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
(236 Series)
Cross sections 0.08 ... 2.5 mm / AWG 28 ... 12
Stripped lengths 5 ... 6 mm / 0.22 in
Accessories
WMB Multi marking system for mounting carrier see page 408
Marker strips for mounting carrier white 709-198 / transparent 709-196
24V 0V
IN OUT GND
0 V
24V 0V
Power supply
Supply via power
jumper contacts
24 V
WAGO Application: Lighting Control System,
easyCredit Stadium in Nuremberg, Germany
WAGO Products:
WAGO-I/O-SYSTEM with ETHERNET Controllers,
Power Supplies Units and
Rail-Mounted Terminal Blocks
5
352
5
5
280/870 Series
Rail-Mounted Terminal Blocks with Overvoltage Protection 358 361
286 Series
Pluggable Modules - Surge Suppression Devices 362 363
Pluggable Modules - Surge Suppression Devices 364 366
792 Series
Rail-Mounted Terminal Blocks with Overvoltage Protection 354 356
Accessories, 792 Series 357
Overvoltage Protection
5
353
5
354
Rail-Mounted Terminal Blocks with Overvoltage Protection
Overvoltage protection for information
technology systems ME24 24 V DC; for
protection of 2 single lines (line/protected
ground), unbalanced interfaces as well as
RS-485 and RS-422 interfaces
Overvoltage protection for information
technology systems MD24 24 V DC; for
protection of balanced interfaces (line/line)
with electrical isolation (telecommunications)
The coordination characteristics give information about the
let-through energy of the overvoltage protector and the
protection capacity.
Description Nominal Voltage Item No.
Pack.
Unit
Nominal Voltage Item No.
Pack.
Unit
Overvoltage protection in terminal block,
for DIN 35 Rail
24 V DC 792-800 1 24 V DC 792-801 1
Technical Data Accessories see page 357 Accessories see page 357
Nominal voltage DC 24 V DC 24 V
Max. cont. operating voltage 33 V DC / 23 V AC 33 V DC / 23 V AC
Nominal current 0.5 A 0.5 A
Nominal discharge current I
SN
(8/20) s 5 kA per line ; 10 kA total 5 kA per line ; 10 kA total
Voltage protection level at I
N
category C2 d 65 V (line/protected ground); d 110 V (line/line) d 50 V (line/line); d 750 V (line/protected ground)
Voltage protection level at 1 kV/s category C3 d 45 V (line/protected ground); d 90 V (line/line) d 45 V (line/line); d 650 V (line/protected ground)
Coordination characteristics X / 1 X / 1
Series impedance R / line 1.8 1.8
Response time t
a
d 1 ns d 100 ns (line/protected ground); d 1 ns (line/line)
Limiting frequency 6 MHz line/protected ground 6 MHz line/protected ground
Capacitance C d 1.0 nF (line/protected ground); d 0.5 nF (line/line) d 5 pF (line/protected ground); d 1 nF (line/line)
Degree of protection IP00 IP00
Degree of protection with end and intermediate plate IP20 IP20
Operating temperature -40 C ... +80 C -40 C ... +80 C
Storage temperature -40 C ... +80 C -40 C ... +80 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals IEC 61643-21 IEC 61643-21
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
1 3
4 2
1 3
4 2
5
355
5
Overvoltage protection for information
technology systems SD24 24 V DC; for
protection of supply lines (power supply units)
Overvoltage protection for information
technology systems MDEX24 24 V DC; for
protection in intrinsically safe circuits
The coordination characteristics give information about the
let-through energy of the overvoltage protector and the
protection capacity.
Description Nominal Voltage Item No.
Pack.
Unit
Nominal Voltage Item No.
Pack.
Unit
Overvoltage protection in terminal block,
for DIN 35 Rail
24 V DC 792-802 1 24 V DC 792-803 1
Technical Data Accessories see page 357 Accessories see page 357
Nominal voltage DC 24 V DC 24 V
Max. cont. operating voltage 33 V DC / 23 V AC 33 V DC / 23 V AC
Max. Input voltage acc. to EN 50020 U
i
30 V
Max. input current acc. to EN 50020 I
i
0.5 A
Nominal current 10 A 0.5 A
Nominal discharge current I
SN
(8/20) s 5 kA (line/protected ground); 300 A (line/line) 5 kA per line ; 10 kA total
Voltage protection level at I
N
category C2 d 50 V (line/line); d 750 V (line/protected ground) d 1500 V (line/protected ground); d 50 V (line/line)
Voltage protection level at 1 kV/s category C3 d 45 V (line/line); d 650 V (line/protected ground) d 1400 V (line/protected ground); d 45 V (line/line)
Coordination characteristics X / 1 X / 1
Series impedance R / line 1.8
Response time t
a
d 100 ns (line/protected ground); d 1 ns (line/line) d 100 ns (line/protected ground); d 1 ns (line/line)
Limiting frequency 7 MHz 6 MHz
Capacitance C d 12 pF (line/protected ground); d 1 nF (line/line) d 6 pF (line/protected ground); d 1 nF (line/line)
Degree of protection IP00 IP00
Degree of protection with end and intermediate plate IP20 IP20
Operating temperature -40 C ... +80 C -40 C ... +80 C
Storage temperature -40 C ... +80 C -40 C ... +80 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals IEC 61643-21 IEC 61643-21
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
1 3
4 2
1 3
4 2
5
356
Rail-Mounted Terminal Blocks with Overvoltage Protection
Overvoltage protection for information
technology systems MD48LON 48 24 V DC;
for protection of LON networks
(FTT 10 or LPT 10)
Overvoltage protection for information
technology systems MDHF5 5 V DC; for
protection of PROFIBUS networks
The coordination characteristics give information about the
let-through energy of the overvoltage protector and the
protection capacity.
Description Nominal Voltage Item No.
Pack.
Unit
Nominal Voltage Item No.
Pack.
Unit
Overvoltage protection in terminal block,
for DIN 35 Rail
48 V DC 792-804 1 5 V DC 792-805 1
Technical Data Accessories see page 357 Accessories see page 357
Nominal voltage DC 48 V DC 5 V
Max. cont. operating voltage 55 V DC / 38.5 V AC 6 V DC / 4.2 V AC
Nominal current 1.7 A 0.1 A
Nominal discharge current I
SN
(8/20) s 5 kA per line ; 10 kA total 5 kA per line ; 10 kA total
Voltage protection level at I
N
category C2 d 100 V (line/line); d 750 V (line/protected ground) d 27 V (line/line); d 50 V (line/protected ground)
Voltage protection level at 1 kV/s category C3 d 70 V (line/line); d 650 V (line/protected ground) d 14 V (line/line); d 14 V (line/protected ground)
Coordination characteristics X / 1 X / 1
Series impedance R / line 0.4 1
Response time t
a
d 100 ns (line/lineound); d 1 ns (line/protected ground) d 1 ns
Limiting frequency 10 MHz 250 MHz / 180 MHz line/protected ground
Capacitance C d 0.6 pF (line/protected ground); d 10 pF (line/line) d 16 pF (line/protected ground); d 19 pF (line/line)
Degree of protection IP00 IP00
Degree of protection with end and intermediate plate IP20 IP20
Operating temperature -40 C ... +80 C -40 C ... +80 C
Storage temperature -40 C ... +80 C -40 C ... +80 C
Dimensions (mm) W x H x L 6 x 56 x 91 6 x 56 x 91
Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Approvals IEC 61643-21 IEC 61131-3
91 mm/3.58 in
5
6
m
m
/
2
.
2
i
n
1 3
4 2
1 3
4 2
5
357
5
Accessories, 792 Series
Operating tool Wire connection Marking pen
with fibre tip
Test pin End and
intermediate plate
Description Item No. Pack. Unit
End and intermediate plate; 1 mm / 0.039 in thick, gray 859-525 100 (4x25)
Test pin; 1 mm / 0.039 in; test wire for sold. onto test plug 859-500 1 (1x1)
Marking pen for permanent marking 210-110 1
Operating tool, with partially insulated shaft Type 2, blade (3.5 x 0.5) mm 210-720 1
Push-in type jumper
bar Commoning
Description Item No. Pack. Unit
Push-in type jumper bars, light gray, insulated, 18 A 2-way 859-402 200 (8x25)
3-way 859-403 200 (8x25)
4-way 859-404 200 (8x25)
5-way 859-405 200 (8x25)
6-way 859-406 100 (4x25)
7-way 859-407 100 (4x25)
8-way 859-408 100 (4x25)
9-way 859-409 100 (4x25)
10-way 859-410 100 (4x25)
Item no. suffix for colored push-in type jumper bars yellow ... /000-029
red ... /000-005
blue ... /000-006
Miniature quick marking card Marking
Description Item No. Pack. Unit
Miniature WSB Quick marking system plain 248-501 5 cards
Marking software and printer/plotter see Section 8
Marking 1 ...10 (10 x) 248-502 5 cards
11 ... 20 (10x) 248-503 5 cards
21 ... 30 (10x) 248-504 5 cards
31 ... 40 (10x) 248-505 5 cards
41 ... 50 (10 x) 248-506 5 cards
1 ... 50 (2 x) 248-566 5 cards
K 1 ... K 10 (10 x) 248-450 5 cards
K 11 ... K 20 (10 x) 248-451 5 cards
K 100 (10 x) 248-452 5 cards
U 1 ... U 10 (10 x) 248-453 5 cards
U 11 ... U 20 (10 x) 248-454 5 cards
U 100 (10 x) 248-455 5 cards
10 strips with 10 markers, white with black printing
5
358
Rail-Mounted Terminal Blocks with Overvoltage Protection
With varistor
V
BN
AC/DC 24 V ... 110/120 V;
I
SN
60 A ... 130 A
Rated current 20 A
Terminal block width 5 mm/0.197 in
With suppressor diode
V
BN
AC/DC 24 V ... AC 230 V;
I
SN
11 A ... 122 A
Rated current 20 A
Terminal block width 5 mm/0.197 in
Through terminal blocks with the same shape
see Full Line Catalog Volume 1
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Terminal block with surge suppression device and
direct connection to DIN 35 rail
24 V DC 280-502/281-609 50 24 V DC 280-502/281-602 50
48 V DC 280-502/281-610 50 48 V DC 280-502/281-603 50
60 V DC 280-502/281-611 50 60 V DC 280-502/281-604 50
115 V DC 280-502/281-612 50 115 V DC 280-502/281-605 50
24 VAC 280-502/281-613 50 24 VAC 280-502/281-606 50
110/120 VAC 280-502/281-614 50 110/120 VAC 280-502/281-607 50
230 VAC 280-502/281-608 50
Technical Data V
N
Max. Operating
Voltage V
B max.
Nominal Discharge
Current I
SN
Max. Surge
Current I
S max.
Capacity
Protection
Level
Terminal blocks with
varistor
24 V DC 31 V DC 60 A 250 A d 1.25 nF 77 V DC
48 V DC 65 V DC 60 A 250 A d 0.72 nF 135 V DC
60 V DC 85 V DC 130 A 1.2 kA d 0.48 nF 165 V DC
115 V DC 150 V DC 130 A 1.2 kA d 0.22 nF 300 V DC
24 VAC 30 V AC 60 A 250 A d 1.05 nF 93 V AC
110/120 VAC 140 V AC 130 A 1.2 kA d 0.18 nF 360 V AC
Terminal blocks with
suppressor diode
24 V DC 30.8 V DC 122 A d 1 nF 64 V DC
48 V DC 58 V DC 59 A d 0.63 nF 111 V DC
60 V DC 77 V DC 44 A d 0.55 nF 162 V DC
115 V DC 136 V DC 25 A d 0.4 nF 282 V DC
24 VAC 28 V AC 86 A d 0.8 nF 84 V AC
110/120 VAC 133 V AC 18 A d 0.35 nF 388 V AC
230 VAC 253 V AC 11 A d 0.36 nF 706 V AC
Technical Data
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 8 ... 9 mm / 0.33 in 8 ... 9 mm / 0.33 in
Accessories Item No. Pack. Unit Item No. Pack. Unit
End and Intermediate Plate, 2.5 mm/0.098 in thick orange 280-341 100 (4*25) orange 280-341 100 (4*25)
gray 280-340 100 (4*25) gray 280-340 100 (4*25)
<_________ 64 mm/2.52 in __________>
(
_
_
_
_
_
_
_
_
_
5
8
,
5
m
m
/
2
.
3
0
i
n
_
_
_
_
_
_
_
_
)
<_________ 64 mm/2.52 in __________>
(
_
_
_
_
_
_
_
_
_
5
8
,
5
m
m
/
2
.
3
0
i
n
_
_
_
_
_
_
_
_
)
5
359
5
With varistor
V
BN
AC/DC 24 V ... AC 230 V;
I
SN
300 A ... 1 kA
Rated current 20 A
Terminal block width 10 mm/0.394 in
With suppressor diode
V
BN
AC/DC 24 V ... AC 230 V;
I
SN
37 A ... 305 A
Rated current 20 A
Terminal block width 10 mm/0.394 in
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Terminal block with surge suppression device and
direct connection to DIN 35 rail
24 V DC 280-502/281-582 25 24 V DC 280-502/281-589 25
48 V DC 280-502/281-583 25 48 V DC 280-502/281-590 25
60 V DC 280-502/281-584 25 60 V DC 280-502/281-591 25
115 V DC 280-502/281-585 25 115 V DC 280-502/281-592 25
24 V AC 280-502/281-586 25 24 V AC 280-502/281-593 25
110/120 V AC 280-502/281-587 25 110/120 V AC 280-502/281-594 25
230 V AC 280-502/281-588 25 230 V AC 280-502/281-595 25
Technical Data V
N
Max. Operating
Voltage V
B max.
Nominal Discharge
Current I
SN
Max. Surge
Current I
S max.
Capacity
Protection
Level
Terminal blocks with
varistor andend plate
24 V DC 31 V DC 300 A 1 kA d 4.6 nF 77 V DC
48 V DC 56 V DC 300 A 1 kA d 2.8 nF 135 V DC
60 V DC 85 V DC 1 kA 4.5 kA d 1.7 nF 165 V DC
115 V DC 150 V DC 1 kA 4.5 kA d 0.8 nF 300 V DC
24 V AC 30 V AC 300 A 1 kA d 3.5 nF 93 V AC
110/120 V AC 150 V AC 1 kA 4.5 kA d 0.57 nF 360 V AC
230 V AC 275 V AC 1 kA 4.5 kA d 0.32 nF 710 V AC
Terminal blocks with
varistor and end plate
24 V DC 28 V DC 305 A d 2.7 nF 59 V DC
48 V DC 53 V DC 162 A d 1.7 nF 111 V DC
60 V DC 70 V DC 123 A d 1.35 nF 146 V DC
115 V DC 128 V DC 68 A d 0.85 nF 265 V DC
24 V AC 26 V AC 258 A d 2.4 nF 70 V AC
110/120 V AC 133 V AC 46 A d 0.63 nF 388 V AC
230 V AC 253 V AC 37 A d 0.4 nF 706 V AC
Technical Data
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / AWG 28 ... 14
Stripped lengths 8 ... 9 mm / 0.33 in 8 ... 9 mm / 0.33 in
<_________ 64 mm/2.52 in __________>
(
_
_
_
3
9
,
5
m
m
/
1
.
5
6
i
n
_
_
_
)
<_________ 64 mm/2.52 in __________>
(
_
_
_
3
9
,
5
m
m
/
1
.
5
6
i
n
_
_
_
)
5
360
Rail-Mounted Terminal Blocks with Overvoltage Protection
With gas filled surge arrester
V
BN
AC 24 V ... 230 V;
I
SN
5 kA
Rated current 20 A
Terminal block width 10 mm/0.394 in
With gas filled surge arrester
V
BN
AC 24 V ... 230 V;
I
SN
5 kA
Rated current 20 A
Terminal block width 10 mm/0.394 in
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Terminal block with surge suppression device and
direct connection to DIN 35 rail
24 V AC/DC 280-503/281-579 25 24 V AC/DC 870-523/281-579 25
110/120 V AC/DC 280-503/281-580 25 110/120 V AC/DC 870-523/281-580 25
230 V AC/DC 280-503/281-581 25 230 V AC/DC 870-523/281-581 25
Technical Data
Max. operating voltage V
B max.
70 V AC/90 V DC
180 V AC/230 V DC
450 V AC/600 V DC
70 V AC/90 V DC
180 V AC/230 V DC
450 V AC/600 V DC
Nominal discharge current I
SN
5 kA 5 kA
Capacity d 2 pF d 2 pF
Protection level 600 V AC
650 V AC
1100 V AC
600 V AC
650 V AC
1100 V AC
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 14 0.08 mm ... 2.5 mm / 4 mm "f" / AWG 28 ... 14
Stripped lengths 8 ... 9 mm / 0.33 in 6 ... 7 mm / 0.26 in
Accessories Item No. Pack. Unit
End and Intermediate Plate, 2 mm/0.079 in thick gray 870-518 100 (4*25)
orange 870-519 100 (4*25)
<_________ 64 mm/2.52 in __________>
(
_
_
_
3
9
,
5
m
m
/
1
.
5
6
i
n
_
_
_
)
<___________ 70 mm/2.76 in ___________>
(
_
_
_
_
4
0
m
m
/
1
.
5
7
i
n
_
_
_
_
)
5
361
5
With varistor
V
BN
AC/DC 24 V ... AC 230 V;
I
SN
300 A ... 1 kA
Rated current 20 A
Terminal block width 10 mm/0.394 in
With suppressor diode
V
BN
AC/DC 24 V ... AC 230 V;
I
SN
37 A ... 305 A
Rated current 20 A
Terminal block width 10 mm/0.394 in
Description V
N
Item No.
Pack.
Unit
V
N
Item No.
Pack.
Unit
Terminal block with surge suppression device and
direct connection to DIN 35 rail
24 V DC 870-523/281-582 25 24 V DC 870-523/281-589 25
48 V DC 870-523/281-583 25 48 V DC 870-523/281-590 25
60 V DC 870-523/281-584 25 60 V DC 870-523/281-591 25
115 V DC 870-523/281-585 25 115 V DC 870-523/281-592 25
24 V AC 870-523/281-586 25 24 V AC 870-523/281-593 25
110/120 V AC 870-523/281-587 25 110/120 V AC 870-523/281-594 25
230 V AC 870-523/281-588 25 230 V AC 870-523/281-595 25
Technical Data V
N
Max. Operating
Voltage V
B max.
Nominal Discharge
Current I
SN
Max. Surge
Current I
S max.
Capacity
Protection
Level
Terminal block with
varistor
24 V DC 31 V DC 300 A 1 kA d 4.6 nF 77 V DC
48 V DC 56 V DC 300 A 1 kA d 2.8 nF 135 V DC
60 V DC 85 V DC 1 kA 4.5 kA d 1.7 nF 165 V DC
115 V DC 150 V DC 1 kA 4.5 kA d 0.8 nF 300 V DC
24 V AC 30 V AC 300 A 1 kA d 3.5 nF 93 V AC
110/120 V AC 150 V AC 1 kA 4.5 kA d 0.57 nF 360 V AC
230 V AC 275 V AC 1 kA 4.5 kA d 0.32 nF 710 V AC
Terminal block with
suppressor diode
24 V DC 28 V DC 169 A d 2.7 nF 59 V DC
48 V DC 53 V DC 90 A d 1.7 nF 111 V DC
60 V DC 70 V DC 69 A d 1.35 nF 146 V DC
115 V DC 128 V DC 68 A d 0.85 nF 265 V DC
24 V AC 26 V AC 258 A d 2.4 nF 70 V AC
110/120 V AC 133 V AC 46 A d 0.63 nF 388 V AC
230 V AC 253 V AC 37 A d 0.4 nF 706 V AC
Technical Data
Wire connection CAGE CLAMP
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / 4 mm "f" / AWG 28 ... 14 0.08 mm ... 2.5 mm / 4 mm "f" / AWG 28 ... 14
Stripped lengths 6 ... 7 mm / 0.26 in 6 ... 7 mm / 0.26 in
<___________ 70 mm/2.76 in ___________>
(
_
_
_
_
4
0
m
m
/
1
.
5
7
i
n
_
_
_
_
)
<___________ 70 mm/2.76 in ___________>
(
_
_
_
_
4
0
m
m
/
1
.
5
7
i
n
_
_
_
_
)
5
362
Pluggable Modules - Surge Suppression Devices
Single stage suppression for 3-wire control,
signal or power circuits
No interruption of current flow when
changing module 24 V AC/DC
Module width 15 mm / 0.591 in
Single stage suppression for 3-wire control,
signal or power circuits
No interruption of current flow when
changing module 110 V / 120 V AC; 230 V AC
Module width 15 mm / 0.591 in
Note:
For isolation measurements the ground (earth) contact at
the transient suppression module must be disconnected.
WSB marker card
Marking F; Item No.: 209-791
Marking 1 ... 10; Item No.: 209-702
Marking Lin, N, PE Lout, N, PE, Lin, N, PE;
Item No.: 249-655
5 cards, each containing 10 strips with 10 markers
Description U
BN
Item No.
Pack.
Unit
U
BN
Item No.
Pack.
Unit
Surge suppression module 24 V AC/DC 286-836 1 230 V AC 286-835 1
115 V AC 286-835/115-000 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal operating voltage V
BN
24 V AC/DC 230 V AC; 115 V AC
Operating voltage 35 V AC / 45 V DC 275 V AC; 150 V AC
Nominal current 10 A 10 A
Nominal discharge current between L/N and PE 300 A 1 kA
Nominal discharge current between L and N 300 A 1 kA
Max. surge current between L/N and PE 1 kA 4.5 kA
Max. surge current between L and N 1 kA 4.5 kA
Protection level between L/N and PE 700 V 1,3 kV; 1 kV
Protection level between L and N 100 V 700 V; 400 V
Response time between L/N and PE 1 s 1 s
Response time between L and N 25 ns 25 ns
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +85 C -25 C ... +85 C
Dimensions (mm) L x H x W incl. terminal block 17 x 82.5 x 73 17 x 82.5 x 73
L
IN
N
PE
L
OUT
N
PE
L
IN
N
PE
L
OUT
N
PE
5
363
5
Single stage suppression for 3-wire control,
signal or power circuits
No interruption of current flow when
changing module with fault indication
110 V / 120 V AC
Module width 15 mm / 0.591 in
Single stage suppression for 3-wire control,
signal or power circuits
No interruption of current flow when
changing module with fault indication
230 V AC
Module width 15 mm / 0.591 in
Note:
For isolation measurements the ground (earth) contact at
the transient suppression module must be disconnected.
WSB marker card
Marking F; Item No.: 209-791
Marking 1 ... 10; Item No.: 209-702
Marking Lin, N, PE Lout, N, PE, Lin, N, PE;
Item No.: 249-655
5 cards, each containing 10 strips with 10 markers
Description U
BN
Item No.
Pack.
Unit
U
BN
Item No.
Pack.
Unit
Surge suppression module 230 V AC 286-838 1 115 V AC 286-838/115-000 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal operating voltage V
BN
230 V AC 115 V AC
Operating voltage 300 V AC 150 V AC
Nominal current 10 A 10 A
Nominal discharge current between L/N and PE 1 kA 1 kA
Nominal discharge current between L and N 1 kA 1 kA
Max. surge current between L/N and PE 2.5 kA 2.5 kA
Max. surge current between L and N 2.5 kA 2.5 kA
Protection level between L/N and PE 1 kV 800 V
Protection level between L and N 800 V 400 V
Response time between L/N and PE 1 s 1 s
Response time between L and N 25 ns 25 ns
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +85 C -25 C ... +85 C
Dimensions (mm) L x H x W incl. terminal block 17 x 82.5 x 73 17 x 82.5 x 73
L
IN
N
PE
L
OUT
N
PE
L
IN
N
PE
L
OUT
N
PE
5
364
Pluggable Modules - Surge Suppression Devices
Three-stage suppression for 2-wire data,
measuring and control circuits 24 V DC
Module width 20 mm / 0.787 in
Three-stage suppression for 3-wire data,
measuring and control circuits 12 V DC
Module width 20 mm / 0.787 in
Note:
For isolation measurements the ground (earth) contact at the
transient suppression module must be disconnected.
WSB marker card
Marking F; Item No.: 209-791
Marking 1 ... 10; Item No.: 209-702
Marking +/-; Item No.: 209-652
Marking Lin, PE, PE, N, Lout, PE, PE, N;
Item No.: 249-652
5 cards, each containing 10 strips with 10 markers
Description U
BN
Item No.
Pack.
Unit
U
BN
Item No.
Pack.
Unit
Surge suppression module 24 V DC 286-833 1 12 V DC 286-834 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal operating voltage V
BN
24 V DC 12 V DC
Operating voltage 30 V DC 14 V DC
Nominal current 0.1 A 6 A
Nominal discharge current between L/N and PE 1.5 kA
Nominal discharge current between L and N 5 kA
Max. surge current between L/N and PE 1.5 kA
Max. surge current between L and N 5 kA
Protection level between L/N and PE d 22 V
Protection level between L and N d 59 V
Response time between L/N and PE d 10 ns
Response time between L and N d 10 ns
Through resistance / inductivity 20 m / 2 x 7 H 50 m / 14 H
Ambient operating temperature -25 C ... +85 C -25 C ... +85 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules, with 2-
conductor terminal blocks, orange separator 22 mm / 0.866 in 280-638 1 22 mm / 0.866 in 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in 280-628 1 22 mm / 0.866 in 280-628 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
25 mm / 0.984 in 280-764 1 25 mm / 0.984 in 280-764 1
+
U
B
L
IN
PE
N
L
OUT
PE
N
5
365
5
Three-stage suppression for 3-wire data,
measuring and control circuits 24 V DC
Module width 20 mm / 0.787 in
Two-stage suppression for 3-wire control,
signal or power circuits 24 V AC/DC
Module width 20 mm / 0.787 in
Note:
For isolation measurements the ground (earth) contact at the
transient suppression module must be disconnected.
WSB marker card
Marking F; Item No.: 209-791
Marking 1 ... 10; Item No.: 209-702
Marking Lin, PE, PE, N, Lout, PE, PE, N;
Item No.: 249-652
Marking PE, N, Lin, PE, N, Lout;
Item No.: 209-911
5 cards, each containing 10 strips with 10 markers
Description U
BN
Item No.
Pack.
Unit
U
BN
Item No.
Pack.
Unit
Surge suppression module 24 V DC 286-834/024-000 1 24 V AC/DC 286-831 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal operating voltage V
BN
24 V DC 24 V AC/DC
Operating voltage 30 V DC 30 V AC / 38 V DC
Nominal current 6 A 6 A
Nominal discharge current between L/N and PE 1.5 kA 200 A
Nominal discharge current between L and N 1.5 kA
Max. surge current between L/N and PE 1.5 kA 500 A
Max. surge current between L and N 1.5 kA
Protection level between L/N and PE d 59 V d 93 V
Protection level between L and N d 93 V
Response time between L/N and PE d 10 ns d 25 ns
Response time between L and N d 25 ns
Through resistance / inductivity 50 m / 14 H 25 m / 2 x 7 H
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3
Ambient operating temperature -25 C ... +85 C -25 C ... +85 C
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules, with 2-
conductor terminal blocks, orange separator 22 mm / 0.866 in 280-638 1 22 mm / 0.866 in 280-638 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in 280-628 1 22 mm / 0.866 in 280-628 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
25 mm / 0.984 in 280-764 1 25 mm / 0.984 in 280-764 1
L
IN
PE
N
L
OUT
PE
N
L
IN
N
PE
L
OUT
N
PE
5
366
Pluggable Modules - Surge Suppression Devices
Two-stage suppression for 3-wire control,
signal or power circuits 24 V AC/DC
Module width 20 mm / 0.787 in
Two-stage suppression for 3-wire control,
signal or power circuits with filter 115 V DC,
230 V DC, 110 V / 120 V AC, 230 V AC/DC
Module width 25 mm / 0.984 in
Note:
For isolation measurements the ground (earth) contact at
the transient suppression module must be disconnected.
WSB marker card
Marking F; Item No.: 209-791
Marking 1 ... 10; Item No.: 209-702
Marking PE, N, Lin, PE, N, Lout;
Item No.: 209-911
5 cards, each containing 10 strips with 10 markers
Description U
BN
Item No.
Pack.
Unit
U
BN
Item No.
Pack.
Unit
Surge suppression module 24 V AC/DC 286-832 1 115 V DC 286-844 1
110 V/120 V AC 286-843 1
230 V DC 286-841 1
230 V AC 286-842 1
Technical Data Accessories see pages 150 ... 151 Accessories see pages 150 ... 151
Nominal operating voltage V
BN
24 V AC/DC 115 V DC; 110 V/120 V AC
230 V DC; 230 V AC
Operating voltage AC 30 V / 38 V DC 180 V DC; 140 V AC
320 V DC; 250 V AC
Nominal current 6 A 6 A
Nominal discharge current between L/N and PE 200 A 600 A
Nominal discharge current between L and N 1.5 kA 600 A
Max. surge current between L/N and PE 500 A 1.5 kA
Max. surge current between L and N 1.5 kA 1.5 kA
Protection level between L/N and PE d 93 V d 900 V
Protection level between L and N d 59 V d 650 V
Response time between L/N and PE d 25 ns d 1 s
Response time between L and N d 5 ns d 25 ns
Through resistance / inductivity 25 m / 2 x 7 H - / 2 x 0.8 mH
Nominal voltage acc. to VDE 0110 Part 1/4.97,
IEC 60664-1
250 V / 4 kV / 3 250 V / 4 kV / 3
Ambient operating temperature -25 C ... +85 C -25 C ... +85 C
Insertion loss 20 dB ... 40 dB / 0.15 MHz ... 30 MHz
Accessories Item No.
Pack.
Unit
Item No.
Pack.
Unit
Terminal block for pluggable modules, with 2-
conductor terminal blocks, orange separator 22 mm / 0.866 in 280-638 1 27 mm / 1.063 in 280-639 1
with 4-conductor terminal blocks, orange separator 22 mm / 0.866 in 280-628 1 27 mm / 1.063 in 280-629 1
with 4-conductor terminal blocks, marker plate
wire range 0.08 mm ... 2.5 mm / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in
25 mm / 0.984 in 280-764 1 30 mm / 1.181 in 280-765 1
L
IN
N
PE
L
OUT
N
PE
L
IN
N
PE
L
OUT
N
PE
5
367
5
WAGO Application: Plastic Technology
Center (SKZ) in Wrzburg, Germany
WAGO Products:
WAGO-I/O-SYSTEM with ETHERNET
Controllers, DALI and EnOcean Components
6
368
6
6
770 Series
WINSTA
ETHERNET
BACnet
The Benefits for Electronic and Radio Technology
Radio connection:
30m in the building, 300m in open field
WAGO Radio Receiver with EnOcean Technology
Radio Receiver in I/O Module
For the seamless integration of EnOcean
technology into the
WAGO-I/O-SYSTEM 750
The module can be used with any controller
of the WAGO-I/O-SYSTEM 750.
Pre-programmed function blocks make
integration easy
The number of sensors is almost illimited
Item No. 750-642
6
370
66
External Antenna
The antenna fits to all WAGO
products shown here and is
connected using an SMA socket.
The antenna has a magnetic stand
and a 2.5m long coax cable.
Item No. 758-910
Radio Receiver in DIN-Rail Mount Enclosure
The stand-alone solution for DIN-rail mounting:
4-channel radio receiver module in 70mm
DIN-rail mount enclosure.
Version 1: 4 make contacts,
up to 16 A load carrying capacity
Version 2: 4 changeover contacts,
up to 8 A load carrying capacity per channel.
Item No. 789-601 (make contacts)
Item No. 789-602 (changeover contacts)
Radio Receiver in WINSTA
Box
All integrated: e.g. a complete blinds control (2-way
sunblind outputs for 230V/2A) or a 4-channel module
for lighting control (4-way switch output 230V/16A)
with receiver and all required switching relay.
The WINSTA
CAGE CLAMP
Cross sections 0.08 mm ... 2.5 mm / AWG 28 ... 12 (THHN, THWN) 0.08 mm ... 2.5 mm / AWG 28 ... 12 (THHN, THWN)
Stripped lengths 5 ... 6 mm / 0.22 in 5 ... 6 mm / 0.22 in
Standards/Specifications Vibration and shock resistance acc. to IEC 60068-2-6 and
IEC 60068-2-27
Vibration and shock resistance acc. to IEC 60068-2-6 and
IEC 60068-2-27
Accessories: RF magnetic antenna incl. 3m connecting
cable with SMA connector
758-910 758-910
24V DC
+ -
4-channel radio receiver
K1...K4
K1...K4
...
14 13 ... 44 43
LRN
Us
EnOcean
Receiver
24V DC
+ -
4-channel radio receiver
K1...K4
K1...K4
...
14 12 11 ... 44 42 41
LRN
Us
EnOcean
Receiver
6
373
6
WINSTA
Radio Receivers
4-channel radio receiver
with 4 make contacts
2-channel radio receiver
with sunblind outputs
The 4-channel radio receiver is used to switch 4
independent electrical devices. The 2-channel radio
receiver has 2 sunblind outputs that can be controlled
independently from each other. The radio receiver
processes telegrams transmitted by switches using
EnOcean radio technology (STM modules). The outputs
are switched via relay contacts.
Radio receiver for battery-less and wireless sensors
LED indication of switch status
External antenna for optimum transmission range
(required)
Frequency band 868 MHz
Transmitter-to-receiver assignment via learn mode
The state of outputs can be predefined for a power
failure scenario
Wire connection using WINSTA connectors
Illustration and block diagram for 770-629/101-000
Description Item No.
Pack.
Unit
Item No.
Pack.
Unit
WINSTA
Cross sections: 0.08 mm
2
... 2.5 mm
2
/AWG 28 ... 14
Stripped lenghts: 5 ... 6 mm / 0.22 in
Top cover 55 mm/2.17 in Pos. 2 789-122 1
Transparent cover Pos. 4 789-124 1
Release mechanism Pos. 3 789-126 1
3-pole terminal block: CCC* Pos. 5 789-127 1
3-pole terminal block: COC* Pos. 5 789-128 1
3-pole terminal block: CCO* Pos. 5 789-129 1
3-pole terminal block: OCC* Pos. 5 789-130 1
3-pole terminal block: OCO* Pos. 5 789-131 1
3-pole terminal block: OOO* Pos. 5 789-132 1
3-pole terminal block: OOC* Pos. 5 789-133 1
3-pole terminal block: COO* Pos. 5 789-134 1
* C = with clamping spring, O = without clamping spring, enclosure open on the right side
PCB dimensions, horizontal mounting
* less 4.5mm when mounting a vertical PCB on level 1
PCB dimensions vertical mounting (max. PCB thickness 1.5 mm) in level 1;
(max. PCB thickness 1 mm) in level 2 and 3
Pos. 2
Pos. 5
Pos. 5
Pos. 3
Pos. 1
Pos. 4
<__________ __________>
<_________________________ _________________________>
<
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
>
<
_
_
_
_
_
_
_
_
_
_
_
_
_
_
>
> <1
29,2
50,2
4
7
,
5
*
1
9
,
5
*
<__________________35__________________>
<
_
_
_
_
1
4
,9
_
_
_
_
>
<___________________________________76,4___________________________________>
<______________________________67,25______________________________>
>
<
5
<
_
_
1
0
_
_
>
<
_
_
_
_
1
4
,9
_
_
_
_
>
<________________________54________________________>
<__________________44,85__________________>
1,2
>
<
5
<
_
_
1
0
_
_
>
<
_
_
_
_
1
4
,9
_
_
_
_
>
1,2
Level 3
Level 2
Level 1
Level 3
Level 2
Level 1
7
383
7
Accessories, 789 Series
Push-in type jumper bars Commoning
Description Item No. Pack. Unit
Push-in type jumper bars uninsulated, 12-way, to be cut to the required length 789-112 100 (4x25)
Operating tool Wire connection Marking pen with fiber tip
Description Item No. Pack. Unit
Operating tool, with partially insulated shaft Type 2, blade (3.5 x 0.5) mm 210-720 1
Marking pen for permanent marking 210-110 1
Miniature quick marking card Marking
Description Item No. Pack. Unit
Miniature WSB Quick marking system plain 248-501 5 cards
Marking software and printer/plotter see Section 8
Marking 1 ...10 (10 x) 248-502 5 cards
11 ... 20 (10x) 248-503 5 cards
21 ... 30 (10x) 248-504 5 cards
31 ... 40 (10x) 248-505 5 cards
41 ... 50 (10 x) 248-506 5 cards
1 ... 50 (2 x) 248-566 5 cards
K 1 ... K 10 (10 x) 248-450 5 cards
K 11 ... K 20 (10 x) 248-451 5 cards
K 100 (10 x) 248-452 5 cards
U 1 ... U 10 (10 x) 248-453 5 cards
U 11 ... U 20 (10 x) 248-454 5 cards
U 100 (10 x) 248-455 5 cards
10 strips with 10 markers, white with black printing
7
384
Mounting Carrier for DIN-Rail Mounting PCBs
Mounting carrier size 1
Description Item No. Pack. Unit
Lateral cover, size 1, small, 6.35 mm /0.25 in thick 288-601 1
Fixing foot for mounting on DIN 35 rails 288-602 1
Track section, size 1, 1 m /33 long 288-600 1
In order to determine the length of a complete mounting carrier:
Length of PCB: L1
Length of track section: L2 = L1 11 mm /0.433 in
Length of mounting carrier: L3 = L1 + 1.7 mm/0.067 in
with lateral cover size 1, 6.35 mm/0.25 in thick.
Distance between PCB and upper groove of track section is 5 mm/0.197 in PCB tolerances: thickness 1.5 mm 0.2 mm, length/width 0.2 mm; -0.1/+0.3 for milling contours
Marker strips
Description Item No. Pack. Unit
Phillips screw 2.9 x 13* * To be used from a module length of 35 mm/1.378 in. For smaller modules
the lateral covers have to be riveted. Rivet length depends on module length.
Rivets not in the WAGO product range.
210-533 25
7.5x0.5mm on roll 5x1m, white 709-198 1
7.5x0.5mm on roll 5x1m, translucent 709-196 1
<____________ 71,2____________>
<_______________ 85 _______________>
<
_
2
5
,
2
_
>
1
1
1
2
,
7
<
<
L
2
<
_
L
3
_
>
<
_
L
1
_>
<
>
<
>
210-533
288-622
288-620
288-621
Mounting carrier size 2
7
385
7
Mounting Carrier for DIN-Rail Mounting PCBs
Mounting carrier size 2
Description Item No. Pack. Unit
Lateral cover, size 2, small*, 8.75 mm /0.344 in thick 288-621 1
Fixing foot for mounting on DIN 35 rails 288-622 1
Track section, size 2, 1 m /33 long 288-620 1
Mounting carrier size 2, with covering section
Description Item No. Pack. Unit
Lateral cover, size 2, big* 8.75 mm /0.344 in thick 288-626 1
Covering section, size 2, 1 m /33 long 288-627 1
In order to determine the length of a complete mounting carrier:
Length of PCB: L1
Length of track section: L2 = L1 15,8 mm/0.622 in
Length of mounting carrier: L3 = L1 + 1.7 mm/0.067 in
Length of covering section: L4 = L1
with lateral cover, size 2, 8.75 mm/0.344 in thick
Distance between PCB and upper groove of track section is 5 mm/0.197 in PCB
tolerances: thickness 1.5 mm 0.2 mm, length/width 0.2 mm; -0.1/+0.3 for milling
contours
<__________________________ 100 __________________________>
<____________________________ 106 ____________________________>
<
_
_
_
2
5
,2
_
_
_
>
<
1
5
,8
>
<
_
1
7
,5
_
>
<
_
_
_
L
2
_
_
_
>
<
_
_
_
_
_
_
_
L
3
_
_
_
_
_
_
_
>
<
_
_
_
_
_
_
_
L
1
_
_
_
_
_
_
_
>
<__________________________ 100 __________________________>
<____________________________ 106 ____________________________>
<
__
1
7
__
>
<
_
_
_
2
2
_
_
_
>
<
_
_
_
_
2
7
_
_
_
_
>
<
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
7
0
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
>
<
_
_
_
_
_
_
_
_
_
_
4
6
_
_
_
_
_
_
_
_
_
_
>
<__________________________ 100 __________________________>
Abdeckprol
210-533
288-622
288-620
288-621
Mounting carrier size 2
7
386
Mounting Carrier and Feet for DIN-Rail Mounting PCBs
Description Item No. Pack. Unit
Mounting carrier For screw-fixing or DIN-rail mounting with snap-fit type universal mounting feet
(then needs 2 x mounting feet) 288-001 1
Universal mounting foot Snap-fit type, suitable for DIN 15, 32 and 35 rails 288-002 10
Universal mounting foot Suitable for Europa card (100 x 160) mm 288-003 1
Description Item No. Pack. Unit
Mounting foot For screw-fixing to relay modules, holes for fixing screws 2 mm/0.079 in,
PCB hole 3.2 mm/0.126 in, distance 18 mm/0.709 in, 209-120 25
Fixing screw For mounting foot 209-120 209-119 50
Description Item No. Pack. Unit
Mounting foot For snap-fit mounting to relay modules, for fixing hole 3.5 mm/0.138 in,
distance 18 mm/0.709 in, for mounting on DIN 35 rail 209-188 25
>
3
<
2
3
,
5
>
<
_
_
_
3
8
,
5
_
_
_
>
<
_
_
_
_
4
2
,
5
_
_
_
_
>
(
_
1
5
_
)
<
_
_
_
_
4
5
,
5
_
_
_
_
>
<_________65,5 _________>
<__________62,5 __________>
Sockelbefestigung
mit Schraube (M 4)
Positionsanschlag
4 mm
<__________________ 42,4 __________________>
>
0,6
<___
<
_
1
0
,
7
_
>
>
4
,
6
<
>
3
,
2
<
>
6
,
4
<
<_______________34,6 _______________>
<_______18_______>
<______18______>
>
0,6
<___
<
_
1
0
,2
_
>
(_5_)
(
_
5
_)
4
,
5
3
,5
0
,0
5
<__________ 38+0,5 __________>
<__ 18 0,1__>
<_______________34,6 _______________>
<___________________ 42,4 ___________________>
xing holes
screw driver removal holes
printed circuit board
7
387
7
WAGO Application: Stockholm-Arlanda Airport,
Sweden
Automated Passenger Boarding Bridges
WAGO Products:
WAGO-I/O-SYSTEM with DeviceNet Couplers and
Rail-Mounted Terminal Blocks
8
388
8
8
211 Series
WAGO Wire and Cable Marking 410 411
ProServe
Designing, Assembling and Marking 394 399
Mobile Printer, Thermal Transfer Printers and Accessories 400 403
Engraving Plotters with Engraver and Accessorie 404 407
Marking Accessories
WMB Multi Marking System, Miniature Quick Marking Card,
WMB Inline, Marker Cards and Group Marker Carriers 408
210, 249 and 209 Series
Carrier Rails 412
Accessories for Carrier Rails 413
206, 210 Series
Tools, Test and Measurement Tools 414 419
790, 791 Series
Shield (Screen) Connecting System 390 393
Accessories
8
389
Shield (Screen) Connecting System
Description and Handling
Carrier with grounding foot
45 mm/1.772 in long, busbar 90 to the rail
Item No. 790-113
for all sizes of shield (screen) clamping saddles
Using a stand off
with a special slotted carrier rail
Addition of a shield (screen) clamping saddle.
Carrier with grounding foot
45 mm/1.772 in long, busbar parallel to the rail
Item No. 790-114
Carrier with 2 grounding feet
125 mm/4.921 in long, busbar parallel to the rail
Item No. 790-115
Tightenning/releasing a shield (screen) clamping saddle. To attach the clamping saddle, tighten the knurled screw. To remove, unscrew until ratcheted
mechanism is released, then slightly tip saddle and remove the clamping saddle.
8
390
Hole dimensions for panel mounting
Mounting Options Based on Application
carrier with grounding foot, busbar parallel to the rail isolated mounting carriers for a common shield (screen) reference potential,
independent of the housing potential
U-shaped copper busbar 10 mm (0.394 in) x 3 mm (0.118 in)
The WAGO shield (screen) connecting system is highly effective
because the clamping unit can be brought very close to the
unshielded part of the cable. Additionally, the spring material is
part of the clamping saddle, giving good electrical connection
and compensating for any deformation in the braiding. The system
also acts as a partial strain relief.
snap into any metal plate up to max. thickness 3 mm/0.118 in
<_ _>
<
_
_
_
_
>
<________ ________>
> <
>
<
<
_
_
_
_
_
>
2
1
4
4 X
Y
m
a
x
.
3
Shield (screen)
clamping saddle size
Distance X
11 mm 9.5 mm
Distance Y
19 mm 17.5 mm
27 mm 25.5 mm
43 mm 41.5 mm
MHz
100 10 1
-100
- 90
- 80
- 70
- 60
- 50
- 40
- 30
- 20
- 10
0
dB
0.1 0.01
Admissible limiting value
Negative shield (screen) attenuation
8
391
8
8
392
Shield (Screen) Clamping Saddles and Shield (Screen) Clamps
Shield (screen)
clamping saddles
Description Diameter of Connectable Conductor Item No. Pack. Unit
Shield (screen) clamping saddle,
incl. knurled screw
11 mm/0.433 in wide up to 8 mm/0.315 in 790-108 50 (5x10)
19 mm/0.748 in wide 7 mm/0.276 in to 16 mm/0.63 in 790-116 50 (5x10)
27 mm/1.063 in wide 6 mm/0.236 in to 24 m /0.944 in 790-124 50 (5x10)
43 mm/1.693 in wide 22 mm/0.866 in to 40 mm/1.575 in 790-140 50 (5x10)
Note: Not for ground connections!
Recommended tightening torque: 0.5 Nm
Assembly: The shield (screen) clamping saddle is shipped ready for direct connection to the busbar 10 mm (0.394 in) x 3 mm (0.118 in) or to a drilled mounting plate. After
connection, tighten the knurled screw to complete the installation.
Removal: To remove a shield (screen) clamping saddle, unscrew until ratcheted mechanism is released, then slightly tip saddle and remove the clamping saddle.
Assembly Removal
Installation
position delivery
Closed position Removal position
Shield (screen) clamps
Description Diameter of Connectable Conductor Item No. Pack. Unit
Shield (screen) camps H
max
40 mm, B 10 mm 1.5 mm/0.059 in to 6.5 mm/0.256 in 791-107 50
H
max
47 mm, B 17 mm 5 mm/0.197 in to 11 mm/0.434 in 791-111 50
H
max
63 mm, B 23 mm 10 mm/0.394 in to 17 mm/0.670 in 791-117 50
H
max
78 mm, B 30 mm 16 mm/0.631 in to 24 mm/0.946 in 791-124 50
Note: Not for ground connections!
<
_
_
_
_
_
_
_
_
_
_
_
_
_
A
_
_
_
_
_
_
_
_
_
_
_
_
_
>
(_10_)
<__B__>
(_C_)
(_C+3 _)
(_10,1_)
<__17__>
<
_
_
_
_
_
_
_
_
_
_
F
_
_
_
_
_
_
_
_
_
_
>
<__D__>
<
_
_
_
_
_
_
_
_
_
_
_
_
_
_
E
_
_
_
_
_
_
_
_
_
_
_
_
_
_
>
790-108
790-116
790-124
790-140
A
51
53
78
97
B
15
15
15
15
C
8
16
24
40
D
16
16
16
16
E
55
57
83
100
F
42
45
58
73
Dimensions in mm
Item No.
<___ _ B____>
<
_
_
_
_
_
_
_
_
_
_
_
_
_
H
m
a
x
. _
_
_
_
_
_
_
_
_
_
_
_
_
>
3
>
<
<________25________>
393
8
8
Accessories for Shield (Screen) Clamping Saddles and Shield (Screen) Clamps
Carrier with grounding foot
Description Item No.
Pack.
Unit
Carrier with grounding foot bar 90 to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu with tin plating, 45 mm/1.774 in long 790-113 25
Carrier with grounding foot bar parallel to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu with tin plating, 15 mm/0.591 in long 790-110 25
Carrier with grounding foot bar parallel to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu with tin plating, 25 mm/0.986 in long 790-112 25
Carrier with grounding foot bar parallel to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu with tin plating, 45 mm/1.774 in long 790-114 25
Carrier with 2 grounding feet bar parallel to the rail, 10 mm (0.394 in) x 3 mm (0.118 in), bar a. foot Cu with tin plating, 125 mm/4.929 in long 790-115 25
Suitable shield (screen) clamping saddle or shield (screen)
clamps for carrier with grounding foot 790-110 = 790-108;
Carrier with grounding foot 790-112 = 790-108, 790-116, 791-111, 791-117;
Carrier with grounding foot 790-114 = 790-108, 790-116, 790-124, 790-140, 791-107, 791-111, 791-117, 791-124
Carrier rail Stand off Shield termination
Description Item No. Pack. Unit
Carrier rail special slotted, 1000 mm/3.3 long, Cu with tin plating, special lengths on request 790-145 1
Stand off for special slotted carrier rail, use M 5 size screw 790-144 200 (2x100)
Shield termination including cable tie for shield
diameter 5 mm /0.197 in to 10 mm /0.394 in 55 mm/2.169 in long 709-350 100 (4x25)
150 mm/ 5.914 in long 709-352 100 (4x25)
Straight busbar Isolated mounting foot Isolated mounting foot U-shaped busbar
Description Item No. Pack. Unit
Straight busbar, 10 mm (0.394 in) x 3 mm (0.118 in), bar Cu with tin plating 1000 mm/3.3 long 210-133 20 (20x1)
30 mm/1.181 in long 790-133 20 (20x1)
50 mm/1.969 in long 790-134 20 (20x1)
Isolated mounting foot for busbar, with standard screw M 4 x 8 mm 790-100 50 (2x25)
Isolated mounting foot for busbar, with sheet metal screw (3.5 x 9) mm 790-101 50 (2x25)
U-shaped busbar, 10 mm (0.394 in) x 3 mm (0.118 in), Cu with tin plating Dimensions (W x H x L) mm; 63 x 60 x 83 790-190 25 (5x5)
Dimensions (W x H x L) mm; 100 x 60 x 118 790-191 25 (25x1)
Dimensions (W x H x L) mm; 63 x 35 x 83 790-192 25 (5x5)
Dimensions (W x H x L) mm; 100 x 35 x 118 790-193 25 (25x1)
Busbar carrier Busbar carrier, angulate
Description Item No. Pack. Unit
Busbar carrier for busbars, 10 mm (0.394 in) x 3 mm (0.118 in) Cu with tin plating 790-300 10
Busbar carrier, angulate for busbars, 10 mm (0.394 in) x 3 mm (0.118 in) Cu with tin plating 790-301 10
15 <_
3
>
>
<
_ 4
<_______________L _______________>
6
1
0
< >
<
>
<_____________B _____________>
<
_
_
_
_
_
H
_
_
_
_
_
>
101,3
70
1
0
5
7
,6
4
5
101,3
70
2
4
3
6
,6
1
0
WAGO ProServe
Designing, Assembling and Marking
8
394
W
A
G
O
-
I
/
O
-
S
Y
S
T
E
M
7
5
0
8
8
395
The advantages of ProServe are at your disposal every
day. With unique features such as AutoAudit accuracy
checking, ProServe performs much of the work for you,
saving time and money.
Immediate access to professional and sophisticated
features allows for error-free applications, greater
flexibility in your daily business and better customer
service. With 50 years of WAGO expertise at your
disposal, put ProServe to work for you in your next
application.
ProServe
Planning
at a New Level
Benets:
Quick design
Quick ordering
User- friendly
Extensive and user- specic
documentation
Network compatibility
Dierent software products on
a single CD (smartDESIGNER,
productLOCATOR, smartSCRIPT)
A price list is included
...all for free!
smartDESIGNER
productLOCATOR
8
396
smartDESIGNER and
productLOCATOR
Interfaces toCAE and
M-CAD programs
Output in PDF and HTML
Dierent search functions provide
quick item selection
Creation of part lists including product
pictures and custom part numbers
Complex rail assemblies can be
easily designed in 3D
Easy creation of custom part numbers
Creation of custom items to design
third- party products
Default parts (favorites) can be
dened individually, streamlining
design time
Intelligent, user- optimized accuracy
check features
18 languages available
25.000 sales items
Marking:
Direct creation and output
of marking data to plotter or
thermal transfer printer
STEP IGES
DXF DWG
CAD
8
8
397
8
398
Configuration and marking of rail
assemblies and I/O nodes, stand-alone
or combined with CAE systems.
ProServe: Planning at a New Level
Snapping:
WMB Inline markers on con-
tinuous reel can be used in
three positions:
In the center and on each
side
Combining marking strips
with individual WMB mar-
kers
Alternative:
Miniature WSB markers
can be printed on a plotter
Both custom rail assembly and marking
can be easily designed via
WAGO ProServe
Software.
Designing:
The marking strip is
snapped into the cen-
ter marker receptacle profile.
8
8
399
smartMARKING
Lxioos|vo |poti luoci|oos lto C^L sysios,
MS Office and WAGO smartDESIGNER
WSlWG ot||og
^uiooi|c p|oiiot co||btoi|oo
Lxioos|vo ||btoty |oc|uo|og ot|ot cott|ots
Sybo| ||btoty
!oxi |oogi| vot|l|coi|oo
Sovoto| |ooguogos ovo||ob|o
Ouipui ol Losi Lutopooo c|otociots
lu||y copoi|b|o w|i| LG 450 Logtovot
L|toci ouipui io i|oto| itooslot pt|oiot
Ctooi|oo ol cusio ot|ots lot
engraver/plotter
Marking strips (2009 Series) or WMB Inline
markers on continuous reel are printed on a ther-
mal transfer printer.
... for clear marking.
This makes it immediately clear which function
corresponds with each terminal block.
Printing: Three-Line Printing:
258-6000, 258-6100
400
8
Mobile Printer
DYMO RHINO 6000
Print-out preparation:
First, insert the label cartridge. To do this, open the cover on the device and in-
sert the cartridge as shown. Ensure the cartridge visibly and audibly locks into
place. The two blue catches must latch on to the top edge of the cartridge. Then
close the cover.
Turn the unit on. A query will appear in the display about setting the material
width. Select your current label width and confirm it with "OK." The unit is now
ready for use.
Note: You can also work with the unit while it is charging.
Please use the latest driver.
Download: www.wago.com under SERVICE / Download / ProServe
Description Item No.
Pack.
Unit
DYMO RHINO 6000 Mobile Printer
Includes: Hard carrying case, AC adapter,
battery, RHINO CONNECT software and
two marking cartridges with 9 mm and
24 mm adhesive strips
258-6000 1
WAGO supplementary set for DYMO
RHINO 6000
Includes: ProServe CD, ProServe flyer and
quick installation guide for adding on to
an existing manual printer
258-6100 1
Technical Data
Resolution 180 dpi
Tape sizes 9 mm, 11 mm, 19 mm, 24 mm
(other sizes upon request)
Tape styles Permanent polyester, flexible nylon, vinyl,
heat shrink tube
Keyboard style ABC
Tape cutter yes
Shock protection yes
Memory 1000 labels (1 MB)
Symbols yes
Barcodes yes (e.g., Code 39, Code 128,
EAN 8 + 13)
Number of font styles 4
Number of font sizes 7
Number of printed lines 5
Print preview yes
PC connection USB
Display 65 mm x 35 mm
Weight 3500 g
Operating time 8 hours
Battery charge indicator yes
8
401
8
Thermal Transfer Printers
WAGO TP 343 and TP 298
Description Item No.
Pack.
Unit
Description Item No.
Pack.
Unit
258-343 1 258-298 1
TP 343 Thermal Transfer Printer
Resolution 300 dpi, incl. ProServe software; for 2009 and 709 Series marking strips
TP 298 Thermal Transfer Printer
Resolution 300 dpi, incl. ProServe software and 258-178 print roller for WMB Inline and
2009 and 709 Series marking strips
Technical Data Technical Data
Printing method Thermal/thermal transfer Printing method Thermal/thermal transfer
Printhead system Thin-film transfer head Printhead system Thick-film
Print resolution 300 dpi Print resolution 300 dpi
Print speed up to 76 mm/sec. Print speed 100 mm/sec.
Print width 6 - 104 mm (0.25" - 4.09") Print width 108.4 mm
Print length up to 990 mm (39") See-through/reflective sensor standard
RAM memory 2 MB DRAM, 1 MB Flash Processor 32 Bit ColdFire/clock rate 64 MHz
Interfaces Parallel Centronics (LPT), RS-232 (COM),
USB, ETHERNET 10/100 Base T
RAM memory 8 MB RAM
Program memory 4 MB Flash
Sensors Label sensor (material end, foil end, bottom
reflective sensor)
Slot for memory card CompactFlash Type 1
Interfaces ETHERNET 10/100 Base T, RS-232
(COM), USB Other 2 cardboard cores (104 mm) for ink ribbon
rewinder; operating instructions in German
and Englisch
Accessories (optional) Cutter, external unwinder, external
rewinder, CompactFlash memory card
16-512 MB Power supply Universal power supply unit
Operating voltage 100 V ... 240 V AC /
50 Hz ... 60 Hz
Operating voltage 100 V ... 240 V AC /
50 Hz ... 60 Hz, PFC
Dimensions (mm) W x H x L 230 x 200 x 290
(Length with unwinder: approx. 450 mm)
Dimensions (mm) W x H x L 242 x 274 x 446
Weight 10000 g
Enclosure Double-walled plastic Operating temperature 10C ... 35C
Weight 1000 g Rel. humidity 30 % ... 85 %
Safety approvals CE, FCC Class A, UL, CUL, TUV Safety approvals CE, FCC class 1
Accessories 1 x USB cable; 1 x ETHERNET cable;
unwinder set;
marking strips (1 x 2009-110);
ink ribbon (1 x 258-145)
Accessories 1 x USB cable; 1 x serial cable;
marking strips (1 x 2009-110);
ink ribbon (1 x 258-149)
Item No.
Application table for ink ribbon/marking accessories/printer
258-143
Ink Ribbon Marking Accessories Width Printer
resin/wax Labels (paper)
Labels (paper)
for cable marking 211-155 / 211-156
Marking cards for wire marking 211-111 and 211-121
Labels (polyester) up to 76 mm
2009 Series marking strip 2009-xxx
709 Series marking strip 709-xxx
WMB Inline (not printable with TP 343)
Marking Strip Series 2009 2009-xxx
Marking Strip Series 709 709-xxx
WMB Inline (not printable with TP 343)
60 mm
100 mm
38 mm
50 mm
76 mm
resin/wax
resin
resin
resin
258-144
258-145
258-149
258-150
all types
all types
TP 298 & TP 343
TP 298+
all types
Labels (polyester) up to 100 mm 100 mm resin 258-157 all types
8
402
Accessories
Accessories for 3M PL300 Mobile Printer
Marking strips Self-adhesive marking Self-adhesive marking Heat shrink tube Heat shrink tube
Description Item No.
Marking strips white, 11 mm width x 5.5 m 211-611
Adhesive strips white, 9 mm width x 7 m 211-612
Adhesive strips white, 19 mm width x 7 m 211-613
Heat shrink tube white, 9 mm width x 1,5 m 211-614
Heat shrink tube white, 19 mm width x 1.5 m 211-615
Accessories for TT Printer
Ink ribbon for labels Ink ribbon for marker strips
Description Item No.
Ink ribbon for marker strips and WMB Inline resin, 38 mm x 300 m 258-145
resin, 50 mm x 300 m 258-149
Ink ribbon for cable marking 76 mm wide x 300 m 258-150
100 mm wide x 300 m 258-157
Ink ribbon for labels resin/wax, width 60 mm x 300 m 258-143
resin/wax, width 100 mm x 300 m 258-144
All ink ribbons are suitable for TP 298 and TP 343 printers. For detailed ordering information, please refer to the
"Application table for ink ribbon/marking accessories/printer"
External coil mounting system Cutter TP 298 Spare roller TP 298
Description Item No.
External coil mounting system for 8,000 WMB Inline markers (2009-135) 258-169
Cutter TP 298 258-161
Spare roller TP 298 for labels (up to device series no. 40,000) 258-162
Spare roller TP 298 for labels (from device series no. 40,000) 258-177
Spare roller TP 298 for WMB Inline (device series no. 40,000) 258-166
Spare roller TP 298 for WMB Inline (from device series no. 40,000) 258-178
Carrying case for TP 298 258-171
Carrying case for TP 343 258-342
Retractable handle for carrying case TP 298 / TP 343 258-173
WMB Inline Marking strips
Description Item No.
WMB Inline, pitch 4 mm, stretchable, 4 mm ... 4.2 mm, on roll white, 2,000 markers 2009-114
WMB Inline, pitch 5 mm, stretchable, 5 mm ... 5.2 mm, on reel white, 1,500 markers 2009-115
WMB Inline, pitch 5 mm, stretchable, 5 mm ... 5.2 mm, on reel white, 8,000 markers 2009-135
Marking strips for TOPJOB
409
8
8
WAGO Wire and Cable Marking
Wire marking
Cable marking
The following marker cards are available:
Marker cards for plotter marking ...
Remove the rest of the card by twisting it off
... or marker cards on roll
for thermal transfer printing
Slide the marker card into the marking sleeve receptacle.
Changing the marking is also
possible after the wire has been connected
Fix the 211-129 marking sleeve using cable ties to
individual wire or cable
Self-laminating labels are available on A4 sheets
for the laser printer (plotter)
or are supplied on roll for the thermal transfer
printer
Remove the printed label from the sheet or roll and wrap
it around the wire or cable.
The transparent laminate protects the marking
8
410
8
411
8
WAGO Wire and Cable Marking
Marking sleeve 12 mm Marking sleeve 23 mm Marking sleeve 23 mm, for cable tie
Description Item No. Pack. Unit
Marking sleeve 12 mm, for wire 1.6 mm ... 3.2 mm or 0.25 mm ... 1.5 mm 211-112 2000
2.2 mm ... 4.5 mm or 0.5 mm ... 4 mm 211-113 2000
3.7 mm ... 5.9 mm or 2.5 mm ... 6 mm 211-114 1000
4.8 mm ... 7.5 mm or 6 mm ... 16 mm 211-115 1000
Marking sleeve 23 mm, for wire 1.6 mm ... 3.2 mm or 0.25 mm ... 1.5 mm 211-122 2000
2.2 mm ... 4.5 mm or 0.5 mm ... 4 mm 211-123 2000
3.7 mm ... 5.9 mm or 2.5 mm ... 6 mm 211-124 1000
4.8 mm ... 7.5 mm or 6 mm ... 16 mm 211-125 1000
Marking sleeve for cable tie 23 mm, for wires from 10 mm 211-129 1000
Cable tie (2.5 x 100) mm 807-090/101-100 1000
Marker card (12 mm)
for Printer
Marker card (12 mm)
for Plotter
Marker card (23 mm)
for Printer
Marker card (23 mm)
for Plotter
Description Item No. Pack. Unit
Marker card for TT Printer 12 mm 211-121 1
23 mm 211-111 1
Marker card for Plotter 12 mm
(258-370 Carrier Plates are required for plotting)
211-120 30
23 mm
(258-370 Carrier Plates are required for plotting)
211-110 18
Labels on roll Labels on DIN A4 sheets Dimensions of self-laminating label
Description Item No. Pack. Unit
Labels on roll for thermal transfer printer Marker surface "S"=8 mm, "B"=18 mm, "L"=35 mm for max. cable 9 mm,
9.000 labels per roll
211-155 1
Marker surface "S"=13 mm, "B"=23 mm, "L"=51 mm for max. cable 12 mm,
5.000 labels per roll
211-156 1
Labels on DIN A4 sheets for laser printer
(258-383 Carrier Plates are required for plotting)
Marker surface "S"=9 mm, "B"=17 mm, "L"=35 mm for max. cable 8 mm,
70 labels per roll
211-150 20
Marker surface "S"=13 mm, "B"=21 mm, "L"=56 mm for max. cable 14 mm,
32 labels per roll
211-151 25
8
412
Carrier Rails
Steel carrier rail
acc. to EN 60715
Steel carrier rail Steel carrier rail
acc. to EN 60715
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
Steel rail, I
N
76 A (referred to a length of 1 m)
35 x 7.5 mm, 1 mm/0.039 in thick, 2 m long, unslotted
Steel rail, I
N
125 A (referred to a length of 1 m)
35 x 15 mm, 1.5 mm/0.059 in thick, 2 m long, unslotted
Steel rail, I
N
125 A (referred to a length of 1 m)
35 x 15 mm, 2.3 mm/0.091 in thick, 2 m long, unslotted
210-113 10 210-114 10 210-118 10
Hole width 25 mm; hole spacing 36 mm, slotted Steel rail, I
N
125 A (referred to a length of 1 m)
35 x 15 mm, 1.5 mm/0.059 in thick, 2 m long, slotted 210-112 10
Hole width 18 mm; hole spacing 25 mm, slotted 210-197 10
210-115 1
Steel carrier rail
galvanized
Copper carrier rail Aluminum carrier rail
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
Steel rail,
35 x 7.5 mm, 1 mm/0.039 in thick, 2 m long, unslotted
Aluminum carrier rail, I
N
76 A (referred to a length of
1 m)
35 x 8.2 mm, 1.5 mm/0.059 in thick, 2 m long, unslotted
Angled support bracket,
without screw
210-505 1 210-148 10
35 x 7.5 mm, 1 mm/0.039 in thick, 2 m long, slotted 210-196 20 Screw M 5 x 8
210-504 1 210-149 100
35 x 15 mm, 1.5 mm/0.059 in thick, 2 m long, unslotted
210-506 1
35 x 15 mm, 1.5 mm/0.059 in thick, 2 m long, slotted
210-508 1
<____ 35 ____>
<___ 27 ___>
>
7
,
5
<
>
<
_
1
<_
36_> (_25_)
>
<
5
,
2
20001,5
<____ 35 ____>
<___ 27 ___> 2000 1,5
>
<
_
1
1
5
(
_
1
5
_
)
>
<
_
1
,
5
2000 1,5
<____ 35 ____>
<__ 24__>
>
<
_
1
1
5
(
_
1
5
_
)
_
_
_
_
_
>
<
2
,
2
-
2
,
5
<____ 35 ____>
<___ 27 ___>
>
7
,
5
<
>
<
_
1
20001,5
>
<
_
1
_
_
_
_
_
>
<
<____ 35 ____>
<__ 24 __>
2
,
2
-
2
,
5
(
_
1
5
_
)
1
5
<____ 35 ____>
<__ 28,2 __>
>
<
1
1
5
>
<
_
1
,
6
8
,
2
20001,5
8
413
8
Accessories for Carrier Rails
End stop for DIN 35 rail
End stop width 6 mm / 0.236 in
Angled support bracket Rail end cap,
for DIN 35 rail (7.5 mm/0.29 in high)
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
End stop, for DIN 35 rail
6 mm/0.236 in wide
Angled support bracket,
without screw
Rail end cap,
for DIN 35 rail (7.5 mm/0.29 in high)
249-116 100 (4 x 25) 210-148 10 209-109 50
End stop, for DIN 35 rail Screw M 5 x 8
249-117 50 (2 x 25) 210-149 100
Snap on - Thats it!
Assembling the WAGO screwless end stops is as simple
and quick as snapping a WAGO railmounted terminal
block onto the rail.
Without any tools!
This way rail-mounted terminal blocks are safely secured at
low cost against any mouvement on all carrier rails DIN 35
acc. to DIN EN 50022 (35 x 7.5 mm; 35 x 15 mm).
Entirely without screws!
The secret of the excellent tight fit lies in the two small
clamping plates which keep the end stop in position, even if
the rails are mounted vertically.
Simply snap on - and forget!
In addition, costs are considerably reduced when using
large numbers of end stops.
A further advantage is that three marker receptacles for all
WAGO marker systems for rail-mount terminal blocks and a
snap-in hole for WAGO adjustable height group marker
carriers offer individual marking possibilities.
Snap on ...
... that's it!!
<___ 45 mm/1.77 in ___>
<
_
2
8
m
m
/
_
_
>
1
.
1
i
n
7
M 5
3
5
<___ 60 ___>
<______ 72 ______>
<
_
_
4
8
_
_
>
>
1
8
<
8
414
Operating tool
Operating tool
with partially insulated shaft
for optimum handling of terminal blocks
Operating tool
with partially insulated shaft
Set
Operating tool
with partially insulated shaft, short
for optimum handling of terminal blocks
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
Operating tool, with partially insulated shaft,
type 1, blade (2.5 x 0.4) mm
Operating tool, with partially insulated shaft,
Set
Operating tool, type 1, short, straight blade
(2.5 x 0.4) mm, with partially insulated shaft
210-719 1 210-722 1 210-647 1
Operating tool, with partially insulated shaft,
type 2, blade (3.5 x 0.5) mm
Operating tool, type 2, short, straight blade
(3.5 x 0.5) mm, with partially insulated shaft
210-720 1 210-657 1
Operating tool, with partially insulated shaft,
type 3, blade (5.5 x 0.8) mm
Operating tool, type 1, short, angled blade
(2.5 x 0.4) mm, with partially insulated shaft
210-721 1 210-648 1
Operating tool, type 2, short, angled blade
(3.5 x 0.5) mm, with partially insulated shaft
210-658 1
Wiring example showing
WAGO-I/O-SYSTEM 750
The operating tool are particularly appropriate for the
operation of front-entry terminal blocks and connectors.
(The picture shows the WAGO-I/O-SYSTEM 750)
8
415
8
Cable Strippers
Cable stripper
for round cables with an outer diameter
from 2.5 mm to 11 mm
Cable stripper
for round cables with an outer diameter
from 4.5 mm to 40 mm
Item No. Pack. Unit Item No. Pack. Unit
Cable stripper
for round cables with an outer diameter
from 2.5 mm to 11 mm
Cable stripper
for round cables with an outer diameter
from 4.5 mm to 40 mm
206-171 1 206-174 1
Item No. Pack. Unit Item No. Pack. Unit
Spare blade for 2.5 mm to 11 mm Spare blade for 4.5 mm to 40 mm
206-170 1 206-173 1
206-171 Cable Stripper:
10-position adjustment wheel ensures repeatable
stripping results
Fine adjustability via 10-position blade cutting depth
adjustment
Strips the sheath from multi-core and fiber optic cables
up to 11 mm/0.43 inch diameter
Safe and easy to use through closed stripping cavity
206-174 Cable Stripper:
Safe and easy to use: Three locking positions for
circular, longitudinal and spiral cuts
High cable stripping capacity of up to 40 mm/1.57
inch diameter
Well balanced, ergonomic design features rests for
thumb, index and pinky fingers to ease raising of the
cable retention hook
Replacement blades can be stored within the tool body
Handling instructions for 206-171 cable stripper
Handling instructions for 206-174 cable stripper
8
416
Wire Strippers
Microstrip wire stripper
0.14 mm ... 1.5 mm/AWG 24 ... 16 "solid" and
"stranded"
Wire cutter up to 1.5 mm/AWG 16 "solid" and
"stranded"
Quickstrip 10 wire stripper
0.02 mm ... 10 mm/AWG 28 ... 8 "stranded"
(6 mm/AWG 10 "solid")
Wire cutter up to 10 mm/AWG 8 "stranded"
(1.5 mm/AWG 16 "solid")
Quickstrip 16 wire stripper
4 mm ... 16 mm
Wire cutter up to 10 mm/AWG 12 ... 6 "stranded"
(1.5 mm/AWG 16 "solid")
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
Microstrip wire stripper Quickstrip 10 wire stripper Quickstrip 10 wire stripper
206-501 1 206-124 1 206-125 1
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
Spare stripping
complete
Standard blade cassette
0.02 mm ... 10 mm/AWG 34 ... 8
Blade cassette 16 mm
4.0 mm ... 16 mm/AWG 12 ... 6
206-502 1 206-126 1 206-128 1
Spare blade for wire cutter "V" blade cassette
0.02 mm ... 4 mm/AWG 34 ... 12 for PTFE 206-503 1
206-127 1
Automatic adjustment to wire size.
No damage to wire strands.
Gripping pressure of jaws adjusts automatically to wire
insulation diameter.
Full cycle strip - jaws open after stripping, ensures no
nicked strands.
Exact strip length may be set by sliding of red setting
stop.
Replaceable stripping jaw assembly.
Self-sharpening, fully protected wire cutter, also
replaceable.*
Glass fiber reinforced polyamide tool body.
* for Microstrip Cutting of wire. Stripping of wire.
Operating instructions are enclosed in the packaging.
8
417
8
Cable Cutter and Crimping Tools
Cable cutter acc. to VDE
for copper and aluminum wires
up to 35 mm/AWG 2
Weight 200 g
Variocrimp 4 Crimping Tool
0,25 mm
2
- 4 mm
2
/ AWG 22 - 12
Weight 400,5 g
Variocrimp 16 Crimping Tool
6 mm
2
- 16 mm
2
/ AWG 10 - 6
Weight 579,5 g
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
Cable cutter Variocrimp 4 crimping tool, for insulated and
uninsulated ferrules, crimping range of 0.25 4 mm
2
Variocrimp 16 crimping tool, for insulated and
uninsulated ferrules, crimping range of 6 16 mm
2
206-118 1
206-204 1 206-216 1
Application notes
With Variocrimp 4, the built-in crimping pressure
control automatically adjusts force to the conductor
cross section used.
With Variocrimp 16, it is necessary to select the wire
gauge on the tool before crimping.
Only one crimping station is needed to handle the
specified conductor size range.
Uniform, compact crimping on all four sides for high
conductor retention.
No need to center the conductor into the ferrule.
Conductor and ferrule insertion possible from both sides
(for left- and right-handers).
Built-in ratchet mechanism ensures gas-tight crimp
connection.
Crimping tools open automatically after crimping
operation is complete.
Ergonomical handles.
Cutting A perfect gastight crimp, both electrically and
mechanically reliable.
What is a gas-tight connection?
In a gas-tight connection, the conductor and the ferrule are compressed together, eliminating all spaces. Under normal
atmospheric conditions, neither a liquid nor a gaseous medium can penetrate into the crimped connection.
Oxidation between crimped single conductors is prevented, ruling out nearly any increase in the crimped connection
resistance. In some exceptional cases, minute, isolated spaces may be present. These can be considered to be closed off
on account of the twisted wires, however.
Inadequate crimping can allow the conductor to be pulled out of the connection. Hollow spaces also remain in which
oxidation can form. Oxidation leads to an increase in contact resistance.
Elevated resistance is detrimental for signal transmission, as the signal flow is damped (weakened), and for power
transmission, as power loss and, hence a temperature increase due to contact (risk of fire) can result.
Crimping tools with built-in ratchets are recommended, such as the WAGO Variocrimp tools. These tools only open after
the crimping process has been fully completed. Space-saving crimping from all four sides is ideal for spring clamp
termination.
Cross section data for ferruled conductors indicated for WAGO products is based on this crimping method.
8
418
Test and Measurement Tools
WAGO Profi LCD+
2-pole voltage tester with LCD display
6 - 1000 V AC/DC
WAGO Profi LED+
2-pole voltage tester with LED display
6 - 1000 V AC/DC
Item No. Pack. Unit Item No. Pack. Unit
WAGO Profi LCD+
2-pole voltage tester with LCD display
Measuring range: 6 V ... 1000 V AC/DC
Degree of protection: IP65
Resistance measurement: up to 2000 ,
removable test probes, 4 mm
WAGO Profi LED+
2-pole voltage tester with LED display
Measuring range: 6 V ... 1000 V AC/DC,
Degree of protection: IP65
Resistance measurement: up to 2000 ,
removable test probes, 4 mm
206-807 1 206-806 1
Item No. Pack. Unit Item No. Pack. Unit
Replacement test probes, 4 mm (2 pcs) Replacement test probes, 4 mm (2 pcs)
206-808 25 206-808 25
Additional product features for WAGO Profi LCD+:
Automatic measurement range selection
Single-pole phase testing AC >100 V
Two-pole sequence testing (R and L)
Continuity testing
FI/RCD testing (30 mA) via buttons
One-hand operation for SCHUKO and CEE sockets
LED torch lamp function
Automatic backlight
Auto power-off function
CAT IV 1000 V
TV/GS tested and approved
IEC/EN 61243-3 (DIN VDE 0682-401)
Additional product features for WAGO Profi LED+:
Automatic measurement range selection
Single-pole phase testing AC >100 V
Two-pole sequence testing (R and L)
Continuity testing
FI/RCD testing (30 mA) via buttons
One-hand operation for SCHUKO and CEE sockets
LED torch lamp function
CAT IV 1000 V
TV/GS tested and approved
IEC/EN 61243-3 (DIN VDE 0682-401)
WAGO Profi LCD+ and WAGO Profi LED+
- Improved socket contact via 4 mm test probes
- Removable test probes for small test ports (suitable for all
WAGO terminal blocks)
8
419
8
WAGO Multi Tester
Digital multimeter
600 V AC/DC
10 A AC/DC
WAGO Amp Tester
Digital clamp meter
0.01 - 200 A AC/DC
Testboy
Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit
WAGO Multi Tester
Digital multimeter with contact-less voltage tester
Measuring range: 600 V AC/DC
10 A AC/DC
Resistance measurement: up to 20 M
Includes: carrying case
WAGO Amp Tester
Digital clamp meter
Measuring range: 0.01 A ... 200 A AC/DC
Degree of protection: IP44
True RMS measuring method
Includes: carrying case
Testboy,
with integrated flashlight
Voltage range 120 V to 1000 V AC
206-810 1 206-815 1 206-804 1
Item No. Pack. Unit
Replacement test leads, red/black
206-811 1
Additional product features for WAGO Multi Tester:
Contact-less voltage test AC >100 V (optical and
acoustical)
Resistance measurement up to 20 M
Acoustical continuity test
Diode test
Data hold function
Auto power-off function
LED torch lamp function
CAT IV 600 V
TV/GS tested and approved
IEC/EN 61010-1 (DIN VDE 0411)
Additional product features for WAGO Amp Tester:
AC and DC current measurement
True RMS measurement
Data hold function
Maximum jaw opening: 21 mm
Compact design for measuring in tight spaces
Resolution: 0.01 A at 40 A
Resolution: 0.1 A at 200 A
Sampling rate: 3 times per second
Auto power-off function
CAT III 300 V
TV/GS tested and approved
IEC/EN 61010-1 (DIN VDE 0411)
A device that will reliably detect AC voltage in cables,
sockets, fuses, switches, outlets, etc.
The voltage tester detects:
Live conductors
Cable breaks
Blown fuses
Defective switches
Defective lamps
9
420
WAGO Application: Opdenho Technologie GmbH
in Hennef, Germany
Control Systems for Weighing, Mixing and
Conveyance of Bulk Material and Liquids
WAGO Products:
WAGO-I/O-SYSTEM with PROFIBUS Couplers,
Rail-Mounted Terminal Blocks
9
9
9
421
Technical Section
Technical Support 422 423
CE Marking and EC Directives 424
General Technical Information for Electrical Equipment
in Hazardous Environments 425
Electromagnetic Compatibility and Mechanical Strength
(Industrial- and Residential Areas) 426
Electromagnetic Compatibility and Mechanical Strength
(Ship Building Area) 427
Specifications and Test Results 428 431
Electrical Engineering Laboratory:
Product Safety for Our Customers 432 433
WAGO Online, eBooks, DVD AUTOMATON 434 435
WAGO Seminars 436 437
Product Support From
Your national WAGO company
or distributor.
Contact
Consulting Services
So|oci|oo ol i|o l|o|obus
0so ol copoooois
Cob|ooi|oo ol copoooois
Coopotoi|oo w|i| oi|ot
suppliers
9
422
The Very Beginning...
Experienced
!to|ooo sioll
lLC & lC cooito|
Mu|i|p|o l|o|obusos
ltogto|og |ooguogos
ltoocis.
Automotive industry
Moc||oo bu||o|og
C|o|co| |oousity
Food processing
Building automation
Process engineering
Process control
and many more
We will help you
ltoouci oocuooioi|oo
Moouo|s
^pp||coi|oo ooios
y io|op|ooo
Oos|io
9
9
423
CE conformity marking:
!|o CL coolot|iy ot||og coos|sis ol i|o
c|otociots "CL, w|i| i|o lo||ow|og sct|pi.
Couooui Lutopoooo [Lutopooo
Couo|iy}
!|o CL ot||og s|o|| bo oll|xoo io i|o
o|ocit|co| ou|pooi, ot |l i|oi |s ooi pos
s|b|o, io i|o so||osi poc||og uo|i. W|i|
i|o CL ot||og, ooulociutots oiiosi coo
lot|iy ol i|o|t ptooucis io i|o to|ovooi
directives.
lo ooo|i|oo io i|o CL ot||og, i|o oou
lociutot ptov|oos oo LC Loc|otoi|oo
ol Coolot|iy lot i|o ptoouci. !||s LC
Loc|otoi|oo ol Coolot|iy usi bo toio|
ned and submitted to a national surveil
|ooco oui|ot|iy upoo touosi. LC o|toci|
vos oto b|oo|og |ogo| togu|oi|oos ol i|o
Lutopooo Couo|iy. !|o|t goo| |s i|o
|otoo|zoi|oo ol |ogo| ooo oo|o|sitoi|vo
togu|oi|oos |o i|o vot|ous LC obot sio
ios, |o otoot io ptovooi itooo obsituci|oos
ouo io o|llotooi ooi|ooo| togu|oi|oos.
lo otoot io ot|oi o ptoouci, |i usi
cop|y w|i| i|o to|ovooi o|toci|vos. !|o
ptoouci oy bo suboci io sovoto| o|toc
i|vos, o.g. i|o LMC ooo i|o |ow vo|iogo
directives.
The EC directives are legally binding
spoc|l|coi|oos ol i|o Lutopooo 0o|oo.
!|o|t o| |s i|o o||goooi ol |ogo| ooo
oo|o|sitoi|vo spoc|l|coi|oos |o i|o vot|ous
LC obot sioios, |o otoot io ptovooi
itoo|og ||ootoocos ot|s|og lto o|llotooi
ooi|ooo| spoc|l|coi|oos.
In order to launch a product on the
ot|oi |i |os io cop|y w|i| i|o to|ovooi
directives. Several directives may apply
io o ptoouci, lot oxop|o i|o LMC ooo
i|o |ow vo|iogo o|toci|vos.
2006/95/EC
Low Voltage Directive
!|o soloiy ol o|ocit|co| ou|pooi |s
guotooiooo by i|o Low \o|iogo L|toci|vo.
This directive covers complete electrical
ou|pooi oos|gooo lot uso w|i| o vo|
iogo toi|og ol boiwooo 50 ooo 1000\
lot o|iotooi|og cuttooi ooo boiwooo 75
ooo 1500\ lot o|toci cuttooi. ltooucis
lo|||og w|i||o i|o scopo ol i|o Low \o|
iogo L|toci|vo i|oi oto oos|gooo |o suc|
o woy i|oi i|oy coo bo usoo |o oi|ot
o|ocit|co| oov|cos ooo w|oso soloiy, lot
i|o osi poti, |s oopoooooi oo |ow i|oso
copoooois woto bu||i |oio i|o ooo pto
ouci ooo w|oi looiutos i|o ooo ptoouci
|os oto ool|ooo os bos|c copoooois |o
occotoooco w|i| i|o Low \o|iogo L|toc
i|vo.* !|o Low \o|iogo L|toci|vo oooso'i
apply to basic components.
2004/108/EC
EMC Directive
!|o LMC L|toci|vo |p||os i|oi o pto
ouci usi ooi i|o |||is ol i|o too|oioo
electromagnetic disturbance and also
requires that a product must be immune
io o|ocitoogooi|c |oiotlotooco. L|oc
tromagnetic passive components or
copoooois w|i| oo o|toci luoci|oo, |||o
tos|siots, o|ooos, copoc|iots, sw|ic||og
to|oys ot cob|os [|o i|o lot ol poss|vo
pt|oioo c|tcu|i bootos} oto ooi coos|ootoo
os oppotoius w|i||o i|o ooo|og ol i|o
LMC L|toci|vo.
Machinery Directive
!|o Moc||ooty L|toci|vo ooos ooi opp|y
to WAGO products.
94/9/EC Ex Protection Directive,
ATEX 100a
Goooto| ioc|o|co| |olotoi|oo lot o|oc
trical equipment in hazardous environ
ments.
CE Marking and EC Directives
9
424
1
2
2
1
l|ooso tolot io i|o oouo|s lot oto |olotoi|oo oo oxp|os|oo ptoioci|oo.
General Technical Information for Electrical Equipment in
Hazardous Environments
Zone 22
Looo 21
Looo 20
Harzardous Environments
Hazardous environments are areas in
w||c| i|o oiosp|oto oy bocoo
oxp|os|vo. Lxp|os|vo oiosp|oto |s
ool|ooo os o |xiuto ol |go|iob|o
subsioocos |o i|o lot ol gosos,
vopots ot |xiutos w|i| o|t uooot
atmospheric conditions in critically
|xoo toi|os suc| i|oi oxcoss|vo ||g|
iopotoiuto, otcs ot spot|s oy couso
oo oxp|os|oo.
LlN LN 11271 ooo o|| oi|ot to|oioo
siooootos i|oi oto cooo|y |oowo
divide up hazardous areas according
io i|o |||o|||ooo ol i|o occuttooco ol oo
oxp|os|vo oiosp|oto |oio i|o lo||ow|og
zooos.
Hazardous environments as a result
ol cobusi|b|o gosos, vopots ot |si.
Zone 0:
Atoo |o w||c| oo oxp|os|vo gos,o|t |x
ture is continuously present or
ptosooi lot |oog pot|oos.
Zone 1:
Atoo |o w||c| oo oxp|os|vo
atmosphere can occur during normal
operation.
Zone 2:
Atoo |o w||c| oo oxp|os|vo
oiosp|oto |s uo|||o|y io occut uooot
ooto| opotoi|oo ooo |l |i ooos |i w|||
bo lot o s|oti pot|oo.
Hazardous areas caused by
combustible dust
Zone 20:
^too |o w||c| oo oxp|os|vo ousiy
oiosp|oto |s ptosooi potooooi|y,
lot |oog pot|oos ot ltouooi|y ooo
|o w||c| oopos|is ol cobusi|b|o ousi
ol uo|oowo ot oxcoss|vo i||c|ooss oy
bo lotoo. Lusi oopos|is o|ooo oto ooi
gtouoos lot c|oss|l|coi|oo os Looo 20.
Zone 21:
^too |o w||c| oo oxp|os|vo ousiy
oiosp|oto |s ptosooi occos|ooo||y
under normal operating conditions and
|o w||c| oopos|is ot |oyots ol
combustible dust can generally be
present.
Zone 22:
^too |o w||c| oo oxp|os|vo ousiy
oiosp|oto |s ooi |||o|y io occut out|og
ooto| opotoi|oo ooo, |l |i occuts, w|||
oo|y ox|si lot o s|oti pot|oo, ot |o w||c|
occuu|oi|oos ot |oyots ol cobusi|b|o
dust are present.
Zone 2
Looo 1
Looo 0
Looo 0 Looo 0
Looo 1
9
9
425
Electromagnetic Compatibility and Mechanical Strength
(Industrial and Residential Areas)
Mechanical strength acc. to IEC 61131-2 (2007)
Test Specication Frequency Range Limit Values
lLC 0082 vibration 5 z l < 9 z 1.75 op||iuoo [potooooi}
2.5 op||iuoo [s|oti iot}
9 z l < 150 z 0.5 g [potooooi}
1 g [s|oti iot}
Noio oo v|btoi|oo iosi.
o} ltouoocy c|oogo. ox. 1 ociovo,|ouio
b} \|btoi|oo o|toci|oo. 2 oxos
lLC 008227 s|oc| 15 g
Noio oo s|oc| iosi.
o} !ypo ol s|oc|. |o|l s|oo
b} S|oc| outoi|oo. 11 s
c} S|oc| o|toci|oo. 2x |o pos|ivo ooo 2x |o oogoi|vo o|toci|oo
lot ooc| ol i|o i|too uiuo||y potpooo|cu|ot oxos ol i|o iosi
specimen
Emission of interference for residential areas acc. to EN 61000-6-3 (2007)
Test Specication Limit Values/ Frequency Range Distance
Quasi Peak
LN 550121 ^C supp|y, coooucioo ... 5 o[\} 150 |z ... 500 |z
LN 550112 5 o[\} 500 |z ... 5 Mz
0 o[\} 5 Mz ... 20 Mz
LN 550121 LC supp|y, 79 o[\} 150 |z ... 500 |z
LN 550112 ooio, coooucioo 72 o[\} 500 |z ... 20 Mz
LN 550122 radiated 20 o[\,} 20 Mz ... 220 Mz 10
27 o[\,} 220 Mz ... 1 Gz 10
LN 55022 !o|ocouo|coi|oos, 84 ... 74 o[\} 150 |z ... 500 |z
Mo|os cooooci|oo 74 o[\} 500 |z ... 20 Mz
Emission of interference for industrial areas acc. to EN 61000-6-4 (2007)
Test Specication Limit Values/ Frequency Range Distance
Quasi Peak
LN 550121 ^C supp|y, coooucioo 79 o[\} 150 |z ... 500 |z
LN 550112 72 o[\} 500 |z ... 20 Mz
LN 550122 radiated 40 o[\,} 20 Mz ... 220 Mz 10
47 o[\,} 220 Mz ... 1 Gz 10
LN 55022 !o|ocouo|coi|oos, 97 ... 87 o[\} 150 |z ... 500 |z
Mo|os cooooci|oo 87 o[\} 500 |z ... 20 Mz
Immunity to interference for industrial areas acc. to EN 61000-6-2 (2005)
Test Specication Test Values Evaluation Criteria *)
LN 100042 LSL 4 |\,8 |\ [cooioci,o|t} B
LN 100042 electromagnetic elds 10 \,. 80 Mz ... 1 Gz A
2\,. 1.4 Gz ... 2.0 Gz A
1\,. 2.0 Gz ... 2.7 Gz A
LN 100044 burst 1 |\,2 |\ [ooio,supp|y} B
LN 100045 surge Loio. , 1 |\ [||oo . ||oo , ||oo . ooti|} B
LC supp|y. 0.5 |\ , 0.5 |\ [||oo . ||oo , ||oo . ooti|} B
^C supp|y. 1 |\ , 2 |\ [||oo . ||oo , ||oo . ooti|} B
LN 10004 RF distrurbances 10 \, 80 ^M [0.15 Mz ... 80 Mz} A
LN 100048 Mogooi|c lo|o 20 ^, 50,0z A
*} Ct|iot|o ^. !|o oov|co usi wot| |o occotoooco w|i| i|o togu|oi|oos out|og ooo oliot i|o iosi.
Ct|iot|o . !|o oov|co usi wot| |o occotoooco w|i| i|o togu|oi|oos oliot i|o iosi.
9
42
Electromagnetic Compatibility and Mechanical Strength
(Ship Building Area)
Immunity to interference acc. to Germanischer Lloyd (2003)
Test Specication Test Values Evaluation Criteria *)
lLC 100042 LSL |\,8 |\ [cooioci,o|t} B
lLC 100042 electromagnetic elds 10 \, 80 Mz ... 2 Gz A
lLC 100044 burst 1 |\ ,2 |\ [ooio,supp|y} A
lLC 100045 sutgo, LC supp|y 0,5 |\ ,1 |\ [||oo . ||oo , ||oo . ooti|} A
sutgo, ^C supp|y 0,5 |\ ,1 |\ [||oo . ||oo , ||oo . ooti|} A
lLC 10004 RF distrurbances 10 \ 80 ^M [0.15 ... 80 Mz} A
Type Test ^l o|situtboocos [|otoo|c wovos} 2 \, 2 W A
Type Test high voltage 755 \ LC
1500 \ ^C
*} Ct|iot|o ^. !|o oov|co usi wot| |o occotoooco w|i| i|o togu|oi|oos out|og ooo oliot i|o iosi.
Ct|iot|o . !|o oov|co usi wot| |o occotoooco w|i| i|o togu|oi|oos oliot i|o iosi.
Emission of interference acc. to Germanischer Lloyd (2003)
Test Specication Limit Values/ Frequency Range Distance
Quasi Peak
Type Test LMC 1, coooucioo 9 ... 50 o[\} 10 |z ... 150 |z
[o||ows lot s||p bt|ogo 0 ... 50 o[\} 150 |z ... 250 |z
cooito| opp||coi|oos} 50 o[\} 250 |z ... 20 Mz
Type Test LMC 1, too|oioo 80 ... 52 o[\,} 150 |z ... 200 |z 3 m
[o||ows lot s||p bt|ogo 52 ... 24 o[\,} 200 |z ... 20 Mz 3 m
cooito| opp||coi|oos} 54 o[\,} 20 Mz ... 2 Gz 3 m
oxcopi lot. 24 o[\,} 15 Mz ... 15 Mz 3 m
Type Test LMC 2, coooucioo 120 ... 9 o[\} 10 |z ... 150 |z
[o||ows lot oc||oo too 79 o[\} 150 |z ... 250 |z
opp||coi|oos} 72 o[\} 250 |z ... 20 Mz
Type Test LMC 2, too|oioo 80 ... 50 o[\,} 150 |z ... 20 Mz 3 m
[o||ows lot oc||oo too 0 ... 54 o[\,} 20 Mz ... 100 Mz 3 m
opp||coi|oos} 54 o[\,} 100 Mz ... 2 Gz 3 m
oxcopi lot. 24 o[\,} 15 Mz ... 15 Mz 3 m
Mechanical strength acc. to Germanischer Lloyd (2003)
Test Specication Frequency Range Limit Values
lLC 0082 v|btoi|oo [coiogoty ^, C} 2 z l < 12,2 z 1.0 ^p||iuoo [potooooi}
12.2 z l < 100 z 0.7 g [potooooi}
Noio oo v|btoi|oo iosi.
o} ltouoocy c|oogo. ox. 1 ociovo,|ouio
b} \|btoi|oo o|toci|oo. 2 oxos
lLC 0082 v|btoi|oo [coiogoty ^L} 2 z l < 25 z 1. ^p||iuoo [potooooi}
25 z l < 100 z 4 g [potooooi}
Noio oo v|btoi|oo iosi.
o} ltouoocy c|oogo. ox. 1 ociovo,|ouio
b} \|btoi|oo o|toci|oo. 2 oxos
9
9
427
Specifications and Test Results
lo poti|cu|ot i|o lo||ow|og siooootos opp|y
io i|o oos|go ooo i|o opp||coi|oo ol i|o
iot|oo| b|oc|s ooo coooociots cooio|ooo |o
i||s coio|og.
LlN \LL 0100.198211
Coosituci|oo ol ||g| cuttooi |osio||oi|oos
w|i| oo|oo| vo|iogos up io 1000\
LN 501101.2004
\LL 01051.20050
Opotoi|oo ol o|ocit|co| |osio||oi|oos
lLC 1140.2001,^1.2004 [oo|loo}
LN 1140.2002,^1.200
\LL 01401.200702
ltoioci|oo ogo|osi o|ocit|c s|oc| Cooo
ospocis lot |osio||oi|oo ooo ou|pooi
lLC 041.2007
LN 041.2007
\LL 01101.200801
losu|oi|oo cooto|ooi|oo lot ou|pooi w|i||o
|owvo|iogo sysios loti 1. lt|oc|p|os,
requirements and tests
lLC 02041.2005 [oo|loo}
LN 02041.200
\LL 01121.20070
Soloiy ol oc||ooty L|ocit|co| ou|pooi
ol oc||oos loti 1. Goooto| tou|tooois
LN 50178.1997
\LL 010.199804
L|ocitoo|c ou|pooi lot uso |o powot
installations
lLC 22051.200
LN 22051.200
\LL 01852051.20010
ltoioci|oo ogo|osi ||g|io|og loti 1.
General principles
lLC 0001.1989
cott|gooou Motc| 1990
L 588.1 S1.1991
\LL 04221.19940
|g| vo|iogo iosi ioc|o|uos, poti 1.
general specications and test
requirements
lLC 0085.2007
LN 0085.2008
\LL 02011.200808
L|ocit|co| |osu|oi|oo !|oto| ovo|uoi|oo
and designation
lLC 0529.1989 ^1.1999
LN 0529.1991 ^1.2000
\LL 04701.200009
Logtoos ol ptoioci|oo ptov|ooo by
ooc|osutos [ll cooo}
lLC 0021.1991 ^1.1992
LN 0021.1998
Coooociots lot ltouooc|os bo|ow 2 Mz
lot uso w|i| pt|oioo bootos loti 1. Gooot|c
spoc|lcoi|oo. Goooto| tou|tooois ooo
gu|oo lot i|o ptopotoi|oo ol ooio||
spoc|lcoi|oos, w|i| ossossoo uo||iy
lLC 1984.2001
LN 1984.2001
\LL 027.200209
Coooociots Soloiy tou|tooois ooo iosis
lLC 09991.1999
LN 09991.2000
\LL 0091.200012
Cooooci|og oov|cos L|ocit|co| coppot
cooouciots, Soloiy tou|tooois lot
sctowiypo ooo sctow|ossiypo c|op|og
uo|is loti 1. Goooto| tou|tooois ooo
poti|cu|ot tou|tooois lot c|op|og uo|is
lot cooouciots 0.2 up io 25
lLC 0172.199
LN 0172.199
Gtop||co| sybo|s lot o|ogtos
loti 2. Sybo| o|ooois, uo||ly|og
symbols and other symbols having
general application
lLC 15581.2005
LN 15581.2005
\LL 05701.20007
Soloiy ol powot itooslotots, powot
supp||os, toociots ooo s|||ot ptooucis
loti 1. Goooto| tou|tooois ooo iosis
lLC 0921.2002
LN 0921.2004
\LL 02221.200508
Sw|ic|os lot |ouso|o|o ooo s|||ot lxoo
o|ocit|co| |osio||oi|oos loti 21. loti|cu|ot
tou|tooois L|ocitoo|c sw|ic|os
lLC 094771.2002
Cott|gooou 1.2002
LN 094771.2002
\LL 0111.200207
Lowvo|iogo sw|ic|goot ooo cooito|goot
loti 71. ^oc|||oty ou|pooi !ot|oo|
b|oc|s lot coppot cooouciots
lLC 099822.2002, oo|loo
LN 099822.2004
\LL 01222.200502
Cooooci|og oov|cos lot |owvo|iogo c|tcu|is
lot |ouso|o|o ooo s|||ot putposos loti
22. loti|cu|ot tou|tooois lot cooooci|og
oov|cos os sopotoio ooi|i|os w|i| sctow|oss
type clamping units
lLC 09471.2007
LN 09471.2007
\LL 00100.200804
Lowvo|iogo sw|ic|goot ooo cooito|goot
loti 1. Goooto| tu|os
lLC 09475.1999
LN 09475.2000
\LL 00212.200012
Lowvo|iogo sw|ic|goot ooo cooito|goot
loti 5. Cooito| c|tcu|i oov|cos ooo
sw|ic||og o|ooois, LC |oiotloco lot
ptox||iy soosots ooo sw|ic||og op||lots
[N^M0k}
lLC 04291.1999 ^1.2004
LN 04291.1999 ^1.2004
\LL 00500.200501
Lowvo|iogo sw|ic|goot ooo cooito|goot
ossob||os loti 1. !ypoiosioo ooo
poti|o||y iypoiosioo ossob||os
lLC 05551.1982 1si oo|i|oo
LN 0555 poti 1, oo|i|oo 1987
\LL 08281.19870
L|siutboocos |o supp|y sysios cousoo by
household appliances and similar electrical
ou|pooi, poti 1. oolo|i|oos
lLC 0715.1981 ^1.1995
LN 0715.2001
L|oos|oos ol |owvo|iogo sw|ic|goot ooo
cooito|goot Siooooto|zoo ouoi|og oo
to||s lot oc|oo|co| suppoti ol o|ocit|co|
oov|cos |o sw|ic|goot ooo cooito|goot
installations
lLC 09501.2005, oo|loo
LN 09501.200
\LL 08051.20011
lolotoi|oo ioc|oo|ogy ou|pooi Soloiy
loti 1. Goooto| tou|tooois
lLC 0127.1994 ^1.199
^2.2002
LN 0127.1994 ^1.199 ^2.2002
\LL 0820.200210
M|o|oiuto lusos loti . luso|o|oots lot
|o|oiuto luso||o|s
9
428
LN 50155.2007
\LL 0115200.200802
ko||woy opp||coi|oos L|ocitoo|c ou|pooi
usoo oo to|||og sioc|
LN 5009022.199 Cott|gooou.1997
^1.2002 ^2.2007
\LL 082922.200711
oo ooo u||o|og L|ocitoo|c Sysios
[LS} loti 22. Sysio ovotv|ow
General technical requirements;
German version
lLC 00991.1991 ^1.1999
LN 00991.1994 ^1.1999
\LL 0751.200008
Sutgo ottosiots loti 1. Noo||ooot tos|siot
iypo goppoo sutgo ottosiots lot o.c. sysios
lLC 1421.1998 Cott|gooou 1998,
modied
LN 14211.2002 ^11.2007
\LL 07511.200708
Lowvo|iogo sutgo ptoioci|vo oov|cos
loti 11. Sutgo ptoioci|vo oov|cos coooocioo
io |owvo|iogo powot sysios
Requirements and tests
lLC 14221.2000 Cott|gooou.
2001
LN 14221.2001
\LL 084521.200202
Low vo|iogo sutgo ptoioci|vo oov|cos
loti 21. Sutgo ptoioci|vo oov|cos coooocioo
to telecommunications and signalling
ooiwot|s, lotlotooco tou|tooois ooo
testing methods
lLC 15081.1998 Cott|gooou 1999
LN 15081.2001
\LL 08021.200211
luoci|ooo| soloiy ol o|ocit|co|,o|ocitoo|c,
ptogtoob|o o|ocitoo|c soloiyto|oioo
sysios loti 1. Goooto| tou|tooois
lLC 201.2005
LN 201.2005
\LL 011250.200510
Soloiy ol oc||ooty luoci|ooo| soloiy
ol soloiyto|oioo o|ocit|co|, o|ocitoo|c ooo
programmable electronic control systems
Interfaces - Fieldbuses
LlN 2591.198105
L|ocit|co| c|otociot|si|cs lot uobo|oocoo
ooub|ocuttooi |oiotc|oogo c|tcu|is
LN 502251.2002
Industrial communications subsystem based
oo lSO 11898 [C^N} lot cooito||otoov|co
|oiotlocos loti 1. Goooto| tou|tooois
lLC 17841.2007
LN 17841.2008
loousit|o| couo|coi|oo ooiwot|s ltol|os
loti 1. l|o|obus ptol|os
lLC 11582.2007
LN 11582.2008
loousit|o| couo|coi|oo ooiwot|s
l|o|obus spoc|lcoi|oos loti 2. l|ys|co|
layer specication and service denition
lLC 1158x
LN 1158x
LlN LN 1158x
loousit|o| couo|coi|oo ooiwot|s
l|o|obus spoc|lcoi|oos loti x
Explosion Protection
lLC 00790.2004, oo|loo
LN 00790.200
\LL 01701.200705
L|ocit|co| oppotoius lot oxp|os|vo gos
oiosp|otos loti 0. Goooto| tou|tooois
lLC 00797.200
LN 00797.2007
\LL 0170.200708
Lxp|os|vo oiosp|otos loti 7. Lu|pooi
ptoioci|oo by |octoosoo soloiy o
lLC 007911.200
LN 007911.2007
\LL 01707.200708
Lxp|os|vo oiosp|otos loti 11. Lu|pooi
ptoioci|oo by |oit|os|c soloiy |
lLC 007914.2007
LN 007914.2008
\LL 0151.200905
Lxp|os|vo oiosp|otos loti 14. L|ocit|co|
|osio||oi|oos oos|go, so|oci|oo ooo otoci|oo
lLC 007915.2005
LN 007915.2005
\LL 01701.20005
L|ocit|co| oppotoius lot oxp|os|vo gos
oiosp|otos loti 15. Coosituci|oo, iosi
ooo ot||og ol iypo ol ptoioci|oo o
electrical apparatus
lLC 12410.2004, oo|loo
Cott|gooou Nov. 2005
LN 12410.200
\LL 0170150.200707
L|ocit|co| oppotoius lot uso |o i|o ptosooco
ol cobusi|b|o ousi loti 0. Goooto|
requirements
lLC 12411.2004
LN 12411.2004
\LL 0170151.20050
L|ocit|co| oppotoius lot uso |o i|o ptosooco
ol cobusi|b|o ousi loti 1. ltoioci|oo by
ooc|osutos iL
lLC 124111.2005
Cott|gooou lobtuoty 200
LN 124111.200
\LL 01701511.200707
L|ocit|co| oppotoius lot uso |o i|o ptosooco
ol cobusi|b|o ousi loti 11. ltoioci|oo by
|oit|os|c soloiy |L
9
9
429
Specifications and Test Results (continued)
Environmental Testing
lLC 0082.2007
LN 0082.2008
\LL 0482.200810
Lov|tooooio| iosi|og loti 2. !osis
!osi lc. \|btoi|oo [s|ouso|oo|}
lLC 008227.1987
LN 008227.1992
os|c oov|tooooio| iosi|og ptocooutos
loti 2. !osis, iosi Lo ooo gu|oooco. S|oc|
lLC 008242.2002
LN 008242.2002
Lov|tooooio| iosi|og loti 242. !osis
!osi Kc. Su|p|ut o|ox|oo iosi lot cooiocis
and connections
lLC 008242.2002
LN 008242.2002
Lov|tooooio| iosi|og loti 242. !osis
!osi Ko. yotogoo su|p||oo iosi lot cooiocis
and connections
EMC Requirements
lLC 10001.2005
LN 10001.2007
\LL 08291.200710
L|ocitoogooi|c copoi|b|||iy [LMC}
loti 1. Gooot|c siooootos luo|iy lot
tos|oooi|o|, cootc|o| ooo ||g|i|oousit|o|
environments
lLC 10002.2005
LN 10002.2005
\LL 08292.20002
L|ocitoogooi|c copoi|b|||iy [LMC}
loti 2. Gooot|c siooootos luo|iy lot
industrial environments
lLC 10002.200
LN 10002.2007
\LL 08292.200709
L|ocitoogooi|c copoi|b|||iy [LMC}
loti 2. Gooot|c siooootos L|ss|oo
siooooto lot tos|oooi|o|, cootc|o| ooo
||g|i|oousit|o| oov|toooois
lLC 10004.200
LN 10004.2007
\LL 08294.200709
L|ocitoogooi|c copoi|b|||iy [LMC}
loti 4. Gooot|c siooootos L|ss|oo
siooooto lot |oousit|o| oov|toooois
lLC 100022.2005
LN 100022.200
\LL 08282.20010
L|ocitoogooi|c copoi|b|||iy [LMC}
loti 22. L||is L||is lot |otoo|c cuttooi
o|ss|oos [ou|pooi |opui cuttooi 1 ^
pot p|oso}
lLC,ClSlk 11.2002 ^1.2004,
oo|loo ^2.200
LN 55011.2007 ^2.2007
\LL 087511.200711
loousit|o| sc|ooi|lc ooo oo|co| [lSM} too|o
ltouoocy ou|pooi
L|ocitoogooi|c o|siutbooco c|otociot|si|cs
L||is ooo oi|oos ol oosutoooi
lLC,ClSlk 22.2005, oo|loo ^1.2005
LN 55022.200 ^1.2007
\LL 087822.200805
lolotoi|oo ioc|oo|ogy ou|pooi koo|o
o|siutbooco c|otociot|si|cs L||is ooo
oi|oos ol oosutoooi
lLC,ClSlk 24.1997, oo|loo ^1.2001
^2.2002
LN 55024.1998 ^1.2001 ^2.2002
\LL 087824.200210
lolotoi|oo ioc|oo|ogy ou|pooi
luo|iy c|otociot|si|cs L||is ooo
oi|oos ol oosutoooi
lLC 12221.2008
LN 12221.2008
\LL 08422021.200811
L|ocit|co| ou|pooi lot oosutoooi,
cooito| ooo |obotoioty uso LMC
tou|tooois loti 21. luo|iy
tou|tooois lot soloiyto|oioo sysios ooo
lot ou|pooi |oiooooo io potlot
soloiyto|oioo luoci|oos [luoci|ooo| soloiy}
General industrial applications
9
420
PLC
lLC 11211.2002
LN 11211.2002
ltogtoob|o cooito||ots
loti 1. Goooto| |olotoi|oo
lLC 11212.2007
LN 11212.2007
\LL 0411500.200804
ltogtoob|o cooito||ots
loti 2. Lu|pooi tou|tooois ooo iosis
lLC 11212.2002
LN 11212.2002
ltogtoob|o cooito||ots
loti 2. ltogto|og |ooguogos
Relays
lLC 18101.2008
LN 18101.2008
\LL 0425201.200902
L|ocitooc|oo|co| o|oooioty to|oys
loti 1. Goooto| tou|tooois
lLC 18102.2005
LN 18102.2005
\LL 0425120.20001
L|ocitooc|oo|co| o|oooioty to|oys
loti 2. ko||ob|||iy
lLC 18105.1998
LN 50205.2002
\LL 04252022.200201
L|ocitooc|oo|co| ooospoc|loo i|o
o||otooi||og to|oys loti 5. losu|oi|oo
coordination
lLC 02555.2000
LN 02555.2001
\LL 0425120.200112
L|ocit|co| to|oys loti 5. losu|oi|oo
cooto|ooi|oo lot oosut|og to|oys ooo
ptoioci|oo ou|pooi kou|tooois ooo
tests
UL Directives
0L 1059, ^NSl 1059.200112
!ot|oo| b|oc|s
0L 48L.200905
Lu|pooi w|t|og iot|oo|s lot uso w|i|
o|u|ou ooo,ot coppot cooouciots
0L 508.199901
Industrial control equipment
^NSl,lS^12.12.01.2007
Noo|ocooo|vo o|ocit|co| ou|pooi lot uso
|o C|oss l ooo C|oss ll, L|v|s|oo 2 ooo C|oss
lll, L|v|s|oos 1 ooo 2 |ozotoous [c|oss|loo}
locations
Ship Classications
^S [^ot|coo utoou ol S||pp|og}
Sioo| \osso|s 2008
loti 4. \osso| Sysios ooo Moc||ooty
\ [utoou \ot|ios}
ku|os lot i|o c|oss|lcoi|oo ol sioo| s||ps ooo
oshore units
LN\ [Loi Nots| \ot|ios}
Loi Nots| \ot|ios' ku|os lot C|oss|lcoi|oo ol
S||ps, |g| Spooo & L|g|i Ctoli ooo
Loi Nots| \ot|ios' OFs|oto Siooootos.
2007
GL [Gotoo|sc|ot L|oyo} 2002
ku|os lot C|oss|lcoi|oo ooo Coosituci|oo
VI Additional Rules and Guidelines
7 Gu|oo||oos lot i|o lotlotooco ol !ypo
Test
2 !osi kou|tooois lot L|ocit|co|,L|ocitoo|c
Lov|cos ooo Sysios
Lk [L|oyos kog|siot} 2002
Type Approval System
!osi Spoc|lcoi|oo Nubot1199
klN^ [kog|sito lio||ooo Novo|o}
ku|os lot i|o c|oss|lcoi|oo ol s||ps
loti C - Moc||ooty, sysios ooo lto
ptoioci|oo C|.2, Soci., !ob|o1
Lo|i|oo 2008
S [loooto| Mot|i|o ooo yotogtop||c
^goocy} 2005
Coti|lcoio oo oosutoooi ol solo o|siooco
to the standard magnetic and steering
ogooi|c coposs |o occotoooco w|i| lSO
k 95 ooo LlN LN 0945 Soci|oo 11.2
Kk [Kotooo kog|siot ol S||pp|og}
L|si ol ^pptovoo Mooulociutots ooo !ypo
^pptovoo Lu|pooi, li. , C|. 1, Soc. 2 ol
i|o ku|os lot C|oss|lcoi|oo ol Sioo| S||ps
NKK [N|ppoo Ko|| Kyo|o|} Lo|i|oo 2009
Gu|oooco lot i|o ^pptovo| ooo !ypo
^pptovo| ol Moiot|o|s ooo Lu|pooi lot
Mot|oo 0so
lkS [lo|s|| koosit Sioi|ow} 2002
lub||coi|oo No. 11,l
Lov|toooio| !osis oo Mot|oo Lu|pooi
9
9
421
9
432
The WAGO laboratory in Minden is an accredited test lab for electrical and mechanical tests on terminal
blocks and connectors, as well as for environment simulations.
Accreditation, as ISO/IEC 17011:2004 denes, is a third party-attestation related to a conformity assessment
body conveying formal demonstration of its competence to carry out specic conformity assessment tasks.
Accreditation, according to DIN EN ISO/IEC 17025, is granted by the Deutsche Akkreditierungsstelle GmbH
DAkkS (German Accreditation Oce GmbH DAkkS). This national accreditation oce, which was established
by the German Federal Ministry for Economics and Technology (BMWi), certies that our test laboratory is
ocially recognized as possessing the necessary expertise to conduct dened tests and types of tests indepen-
dently and objectively.
Through obtaining the accreditation, the following objectives were achieved:
Cusioot tou|tooois
Wot|low opi||zoi|oo
C|oot|y oolooo ptocossos
C|oot otgoo|zoi|oo ooo situciuto
Greater transparency
Coos|siooi, ||g|uo||iy |obotoioty iosi|og
Mox|u itocoob|||iy
!tocoob|o oosutoooi tosu|is
Susio|oob|o uo||iy owotoooss
Conductor reten-
tion force testing
Vibration- and
shock-resistance
testing
Electrical Engineering Laboratory:
Product Safety for Our Customers
Visitor center
High-voltage test
9
433
9
9
434
WAGO online
You want to get informed on our products
quickly and conveniently?
You want more information on our
company? No problem!
At www.wago.com you will nd a wealth
of information on WAGO:
lolotoi|oo oo out copooy
!|o |oiosi ptoouci oows
!|o oowosi oouo|s, ooio s|oois,
brochures and yers in dierent formats
Loios lot i|o ooxi so|oots,
|olotoi|oo ovoois, tooos|ows, itooo
fairs and much more...
We are continuously working on improving
i|o sotv|co soci|oo ol out wobs|io. lo ooo|i|oo
to product documentation and information
tosoutcos [|o boi| lLl ooo oboo| lotoi},
software downloads are also available from
this section.
ll you |ovo ooy uosi|oos oo o poti|cu|ot
iop|c, p|ooso uso out co||boc| sotv|co ooo
we will call you back whenever it is
convenient for you.
Koop upioooio. \|s|i us oo||ool
www.wago.com
Keep up-to-date.
Visit us online!
9
435
9
Start: index.html
Release 2012/03-021
No. 0888-0412/0021-0101
www.wago.com
AUTOMATION
Tools and Docs
by W
AGO. This work is protected by copyright. All rights reserved by the ow
ner a
nd
p
ro
d
u
c
e
rs. A
n
y
u
n
a
u
th
o
riz
e
d
c
o
p
y
in
g
, h
irin
g
, le
n
d
in
g
o
r p
u
b
l i c
p
e
r f o
r m
a
n
c
e
o
f t h
i s
D
V
D
i s p
r o
h
i b
i t e
d
.
Rel. 021
2012/03-021
AUTOMATION Tools and Docs
eBooks
lo i|o sotv|co soci|oo ol out wobs|io, you w||| loo i|o |oiosi ptoouci coio|ogs ooo btoc|utos os |oiotoci|vo
ooo|s. ^ sootc| ooo zoo luoci|oo o||ows you io u|c||y loo oxoci|y w|oi you oto |oo||og lot.
!|o oyoo|c cooiooi o|os |oolog i|toug| i|o pogos uc| oos|ot, ooo |l you ptolot o |otocopy, s|p|y
print out the pages you want to read.
lo ooo|i|oo io i|o |oiosi ioc|o|co| oocuooioi|oo, i||s
L\LkOM o|so cooio|os out ^0!OM^!lON ptoouci
catalogs and brochures as interactive eBooks.
!|o ioc|o|co| oocuooioi|oo |oc|uoos s|oti oosct|pi|oos,
opp||coi|oo ooios, ooio s|oois ooo oouo|s lot o|| out
^0!OM^!lON ptooucis.
Specic information resources on our electronic
copoooois coo bo v|owoo |o lLl lotoi. ll you oto
to|uciooi io |ool i|toug| oss|vo coio|ogs, you coo o|so
btowso o|| ^0!OM^!lON coio|ogs uoo btoc|utos os
ooo|s, ol coutso, w|i| sootc| ot |oywoto luoci|oo.
lo ooo|i|oo, o|| W^GOl,OSS!LM soliwoto ptooucis
[w||c| coo o|so bo louoo oo out wobs|io} coo bo o|toci|y
|osio||oo lto i|o L\LkOM.
L\L AUTOMATION !oo|s ooo Locs
9
436
WAGO Seminars Learn Today
Benefit Tomorrow
Experience has shown that
practice makes perfect. The focus
of every WAGO training seminar
is on practical, hands-on learning.
No question goes unanswered
and no one is overlooked in
WAGO training courses made
up of small groups.
Learning is effective in a group.
Ideas can be discussed and ex-
changed while experiences can
be shared all for the benefit of
the participants.
Innovative ideas and advanced technology are
the driving forces behind the development and
creation of WAGOs market-leading products.
Maximize the benefits of WAGO products
through optimal application knowledge
gained at WAGO training seminars. The skills and
expertise gained in our effective, user-oriented pre-
sentations will save you time and help you use our
products to their fullest capacity.
Product-related and customer-specic training seminars
Setting the Bar with Your Goals
Practical Topics Small Groups Teamwork
9
437
9
WAGO Seminars
Efficient and Practical Training
Current sem
inars at:
www.wago.com/seminare
Special
com
pany sem
inars
Product-Related Seminars
In addition to these open seminars, we also offer customer-spe-
cific courses as company seminars to address your companys
particular needs.
Upon request, we can also conduct these courses at your location.
We regularly offer product-related training courses on the
following:
Building and industrial automation
Programming of automation components
Fieldbus systems
WAGO Seminars Experience the benets
of rst-hand knowledge and expertise
straight from the source!
Your instructor is a specialist and knows all the ins
and outs of the topic. Carefully developed, each
WAGO training seminar ensures that every minute
spent is an eective investment of your expertise.
Request your registration form by e-mail:
training@wago.com
Contact Your Local
WAGO Company.
Customer-Specic Training Seminars
10
438
10
10
10
439
Index
Item Number Index
WAGO Locations
Index 440 445
Item Number Index 446 451
WAGO Locations Worldwide 452 453
Catalog
Catalog (Page)
Catalog Catalog
1 = Full Line Catalog Volume 1 (Rail-Mounted Terminal Block Systems), 2 = Full Line Catalog Volume 2 (Connectors and PCB Terminal Blocks)
3 = Full Line Catalog Volume 3 (I/O-SYSTEM), 4 = Full Line Catalog Volume 4 (Interface Modules), 5 = Full Line Catalog Volume 5 (WINSTA
)
f.-e. = front-entry, s.-e. = side-entry
Catalog (Page) Catalog (Page)
Catalog (Page)
A
Actuator and actuator LED terminal blocks
rail-mounted terminal blocks 1
Actuator cables 3
Additional modules for matrix patchboards 1
Addressing tool 3
Alu Plus contact paste 1, 2
Analog input modules 3
Analog output modules 3
Analog signal conditioning modules
- pluggable 4(278-280)
AND gate modules
- pluggable 4(146)
Angled female connectors
see MULTI CONNECTION SYSTEM, 100%
protected against mismating, classic/standard
version 2
Angled support brackets 1, 3
Antenna (SMA plug) 4(374), 3
Approvals 1, 2, 3
Approvals for WAGO-I/O-SYSTEM 3
AS-Interface master module 3
AS-Interface switch mode power supply 4(320), 3
Assembly tools for 294 Series 1
B
Back-up capacitor module 4(351), 3
BACnet congurator 3
Banana plugs 1
Binary spacer module 3
Bipolar isolation amplier 4(224)
Bistable relays
- DIN-rail-mountable 4(107)
- pluggable 4(121)
Block I/O SYSTEM 3
Bluethooth I/O module 3
Bridge rectiers 4(142-143)
Building automation 3
Bus coupler units for KNX/EIB applications 2
Busbar terminal blocks 1
C
Cable assemblies
- WINSTA
MINI 5
- WINSTA
MIDI 5
- WINSTA
RD 5
- WINSTA
KNX 5
Cable assembly 3
Cable marking 4(410-411), 1, 3
Cable stripper 4(415), 1, 2, 3, 5
Cables and connectors 3
Cables and connectors for eldbus systems 3
Cables, pre-assembled
WINSTA
MINI 5
WINSTA
MIDI 5
WINSTA
RD 5
WINSTA
KNX 5
CAGE CLAMP
connection 4(2), 1, 2, 3
CAGE CLAMP
S connection 4(2), 1, 2, 3
CAL
eldbus components 3
CANopen
eldbus components 3
Carrier rails 4(412), 1, 2, 3
C
Carrier terminal blocks, f.-e. 1
- double-deck, triple-deck terminal blocks 1
X-COM
S-SYSTEM-MINI 1
TOPJOB
S 1
X-COM
-SYSTEM 1
X-COM
S-SYSTEM 1
CC-Link eldbus connector 3
CC-Link eldbus coupler 3
CE marking 4(426), 1, 2, 3
Chassis-mount terminal strips 1
Coding keys 2
Coding pin, WINSTA
5
Coding, WINSTA
5
Collective carrier for jumpers 1
Combi PCB terminal blocks 2
Combi strips 2
Comb-style jumper bars 1, 2
Comb-style jumper bars 2
Commissioning software 4(268), 3
Common potential matrix patchboards 1
Commoning strips for PCB terminal blocks 2
Compact block terminal blocks 1
COMPACT PUSH WIRE
S 1
- WINSTA
5
- X-COM
-SYSTEM 1
Connectors for junction boxes 1
Constant voltage sources
- DIN-rail-mountable 4(242-243), 3
Control panel 3
Covers for rail-mounted terminal blocks 1
Crimping tools for ferrules 1, 2
CT/VT terminal blocks
see Disconnect/Test terminal blocks
Current ow monitoring modules
- pluggable 4(140-141)
Current-carrying capacity curves
- PCB terminal blocks 2
- X-COM
-SYSTEM 1
- MULTI CONNECTION SYSTEM
D
DALI/DSI master module 3
Data exchange coupler 3
Data exchange module 3
DC drive controller 3
DC/DC converter
- Rail-mounted terminal block 4(348-349)
- DIN-rail-mountable 4(350)
Decade marker carrier 1
Decentralized building automation 3
Delta jumpers 1
Derating curves
see current-carrying capacity curves
MULTI CONNECTION SYSTEM 2
Device connectors
- WINSTA
MINI 5
- WINSTA
MIDI 5
DeviceNet
eldbus components 3
Dierencial inputs and dierential measurement
inputs
see Analog input modules 3
Digital impulse interface 3
Digital input modules 3
Digital output modules 3
Diode double-deck terminal blocks, f.-e. 1
TOPJOB
S 1
Diode gate modules
- DIN-rail-mountable 4(210-211)
- pluggable 4(145)
Diode modules, for carrier or through terminal
blocks, pluggable 1
Diode terminal blocks, f.-e. 1
TOPJOB
S 1
Diode triple-deck terminal blocks, f.-e. 1
TOPJOB
S 1
Direct printing
- MICRO 2
- MINI 2
- MIDI 2
- MAXI 2
Disconnect terminal blocks, f.-e.,
- angled type
with pivoting knife disconnect 1
- horizontal type
Double-deck terminal blocks 1
with disconnect tab 1
Disconnect/Test terminal blocks, f.-e.
- angled type
for use with voltage transformer circuits or current
transformer circuits 1
- horizontal type
with pivoting knife disconnect 1
TOPJOB
S 1
with pivoting disconnect link 1
Disconnect/Test terminal blocks, s.-e. 1
Disconnection tools for 294 Series 1
Distribution box, WINSTA
5
Distribution cables (sensor/actuator) 3
Distribution connector, WINSTA
- MINI 5
- MIDI 5
- KNX 5
Distribution installation terminal blocks
see also Multilevel installation terminal blocks
Distribution terminal blocks, f.-e.
see TOPJOB
S 1
DLL MODBUS
/TCP software 3
Documentation 4(434-435), 3
Double pin headers
see MULTI CONNECTION SYSTEM MIDI
Index
10
440
Catalog Catalog Catalog
Catalog (Page) Catalog (Page) Catalog (Page)
D
Double-deck headers
MULTI CONNECTION SYSTEM 2
Double-deck Terminal Blocks, f.-e. 1
TOPJOB
S 1
diode terminal blocks, LED terminal blocks 1
TOPJOB
S 1
Double-deck terminal strips for PCBs 2
Double-potential terminal blocks, f.-e. 1
TOPJOB
S 1
for matrix patching 1
Down counter see Up/down counters
D-Sub eldbus connector 3
DVD AUTOMATION Tools and Docs 4(435), 3
E
e-Books 4(435), 3
EC directives 4(426), 1
EDS les see Conguration les
for building custom circuits 4(378-379)
for rail-mounted terminal blocks 4(380)
Empty housings
Rail-mounted terminal block empty housings 4(381)
Enclosures for WAGO-I/O-SYSTEM 750 3
End module 3
End stops
- for DIN 15 rail 1
- for DIN 35 rail 4(413), 1, 3
Engraving plotter with engraver 4(404-405), 3
EnOcean radio switching receiver 4(272), 3
EnOcean radio technology 4(370-371), 3
EnOcean switches 4(374), 3
EPSITRON
S 1
Double-potential terminal blocks, f.-e. 1
Through terminal blocks, f.-e.
- angled type 1
TOPJOB
1
TOPJOB
S 1
- horizontal type 1
TOPJOB
S 1
Modular terminal blocks and terminal strips with
xing anges or mounting feet
- f.-e. 1
- s.-e. 1
PCB terminal blocks 2
Miniature through terminal blocks, f.-e. for DIN 15
rail and DIN 35 rail 1
MINI ground conductor terminal blocks for DIN 15
and DIN 35 rails 1
Ex i
Fieldbus modules 3
Terminal blocks see Through terminal blocks
Ex Technical information 4(425), 1, 3
Extended input voltage and temperature range
4(48)
F
Feedthrough pluggable connectors for PCBs
see MULTI CONNECTION SYSTEM 2
Feedthrough terminal strips
for PCB 2
Felt-tip pen 4(49), 1, 2, 3
Female and male connectors
see Connectors, for ex. for racks
Female PCB connectors 2
Female PCB terminal blocks 2
Female plugs
see MULTI CONNECTION SYSTEM 2
X-COM
-SYSTEM 1
X-COM
S-SYSTEM-MINI 1
X-COM
S-SYSTEM 1
Female sockets for elevator shaft technology 2
Ferrules 4(91), 1, 2
TOPJOB
S 1
4-conductor chassis-mount terminal strips 1
Field side connection module 3
Field side power supply lter module 3
Fieldbus components 3
Fieldbus connectors 3
Fieldbus controllers 3
Fieldbus couplers 3
Filter modules 3
Fire load
FIT CLAMP
connection
(insulation displacement connection) 1
Fixing ange MCS-MIDI 100% protected against
mismating
- 5 mm 2
- 7.5 mm 2
Fixing ange MCS-MIDI Classic
- 5/5.08 mm 2
- 7.5/7.62 mm 2
Fixing ange MCS-MINI
3.5/3.81 mm 2
Flip-Flop module 4(147)
Function blocks for building automation 3
Function modules 4(112)
Fuse plugs
- for carrier terminal blocks 1
Fuse terminal blocks, f.-e.
- angled type
for mini-automotive blade-style fuses 1
with pivoting fuse holder 1
- horizontal type, TOPJOB
S 1
with pivoting fuse holder 1
Fuse terminal blocks, s.-e. 1
G
Gate modules
- DIN-rail-mountable 4(210-214)
- pluggable 4(145-146)
Ground conductor disconnect terminal blocks, f.-e. 1
TOPJOB
S 1
Ground conductor disconnect terminal blocks, s.-e. 1
Ground conductor terminal blocks with insulation
displacement
(FIT CLAMP
) connection 1
Ground conductor terminal blocks, f.-e.
- angled type 1
Supply terminal blocks 1
TOPJOB
S 1
- horizontal type 1
5mm wide; 4mm 1
Double-deck terminal blocks 1
G
Ground conductor terminal blocks, f.-e.
Triple-deck terminal blocks 1
TOPJOB
S
Ground conductor terminal blocks, miniature type for
DIN 15 and DIN 35 rails 1
Ground conductor terminal blocks, s.-e. 1
High-current terminal blocks 1
Group marker carriers 4(408), 1, 3
TOPJOB
S 1
GSD les
see Conguration les
H
h-distribution connector
- WINSTA
MINI 5
- WINSTA
MIDI 5
Headers for double-deck assembly MULTI
CONNECTION SYSTEM 2
High-current connectors 1, 2
High-current PCB terminal blocks 2
High-current, rail-mounted terminal blocks with
POWER CAGE CLAMP connection 1
I
I/O enclosures 3
I/O modules
see WAGO-I/O-SYSTEM 3
I/O modules for severe conditions
- WAGO-I/O-SYSTEM 755 3
I/O-SYSTEMS 3
IEC/EN specications 4(428-431), 1, 2, 3
II/O-LIGHTBUS eldbus components 3
Incremental encoder interface 3
see LED gates, LED indicators, LED terminal
blocks
Industrial compact PC 3
Industrial PC 3
Industrial relays 4(92-98)
Industrial switches 3
Input voltage range, extended 4(48, 150)
Insulation displacement (FIT CLAMP
) connection 1
Insulation stop
for matrix patchboards 1
for rail-mounted terminal blocks 1
for MCS 2
Integrated end plate for group formation
Loss of pin spacing 2
INTERBUS
eldbus components 3
Interface modules 4(Section 2)
- for ETHERNET 4(204-206)
- for ERNI mating connector 4(186)
- for Harting mating connector 4(186)
- for Siemens SIMATIC 4(191-194)
- for connectors 4(186-189)
- with header 4(185)
- with D subminiature connector 4(176-183)
Interface software 3
Interference-free in safety functions 3
Intermediate coupler, WINSTA
- MIDI 5
Internal data bus extension modules 3
10
441
10
Catalog
Catalog (Page)
Catalog Catalog
1 = Full Line Catalog Volume 1 (Rail-Mounted Terminal Block Systems), 2 = Full Line Catalog Volume 2 (Connectors and PCB Terminal Blocks)
3 = Full Line Catalog Volume 3 (I/O-SYSTEM), 4 = Full Line Catalog Volume 4 (Interface Modules), 5 = Full Line Catalog Volume 5 (WINSTA
)
f.-e. = front-entry, s.-e. = side-entry
Catalog (Page) Catalog (Page)
Catalog (Page)
I
Intruder detection
see Digital input modules 3
IO-Link Master 3
Item number index 4(446-451), 1, 2, 3, 5
J
Jumpers for rail-mounted terminal blocks
see push-in type wire jumpers, staggered jumpers,
step-down jumpers
JUMPFLEX
Transducers 4(Section 3)
Sockets with solid state relay 4(54-61)
Sockets with miniature switching relay 4(50-52)
Junction and distribution connectors, MICRO for
KNX/EIB applications 2
K
KAMMRELAIS
4(110-111)
KNX IP controller 3
KNX/EIB/TP1 module 3
L
Labeling 1, 2, 3
Lamp demonstration connector
(Service connector) 1
Lamp test circuit gate modules
- DIN-rail-mountable 4(213)
Latching relays 4(158)
LED and neon indicators, pluggable 1
LED gate modules
- DIN-rail-mountable 4(213)
- pluggable 4(146)
LED terminal blocks, f.-e. 1
TOPJOB
S 1
LED terminal blocks, f.-e.
double-deck terminal blocks 1
TOPJOB
S 1
LED terminal blocks, f.-e.
triple-deck terminal blocks 1
TOPJOB
S 1
Lighting connectors 1
Lighting control DALI/DSI 3
Lighting protection 4(352-366)
Linect
5
Linux
controller 3
Locking levers
- WINSTA
MINI 5
- WINSTA
MIDI 5
Lockout cap, WINSTA
- MINI 5
- MIDI 5
Lockout caps 2
Longitudinal switching disconnect
terminal blocks 1
LONWORKS
eldbus components 3
Luminaire connectors 1
M
Magnetic antenna 4(374), 3
Male and female connectors
see Connectors, for ex. for racks
Manual control module 4(173)
Manuals for eldbus components 3
Marker branches 1
Marker cards
Miniature WSB Quick marking system
(miniature WSB cards) 4(408), 1, 2, 3
Self-adhesive marker strips, computer-marked 1, 2
WAGO Multi marking system
(WMB cards) 4(408), 1, 2, 3
WAGO WSB Quick marking system
(WSB cards) 4(408), 1
Marker carrier 3
Marker carriers 1
Marker for WAGO group marker carriers 4(408), 1,
3
Marker strips for TOPJOB
S 1
Marker strips, self-adhesive 2, 3
Marker tags 1
Marking 4(408), 1, 2, 3, 5
Material specication for insulation materials,
contact materials, contact surface 1, 2
Measurement and disconnect terminal blocks
see Disconnect terminal blocks for test and
measurement
MICRO PUSH WIRE
connectors for
junction boxes 1
Millivolt transducer 4(248-249)
Miniature ground conductor terminal blocks, f.e.
for DIN 15 and DIN 35 rails 1
Miniature switching relays 4(32-38, 50-52)
Miniature through terminal bolcks, f.-e.
for DIN 15 and DIN 35 rails 1
Miniature WSB Quick marking system
(marker cards) 4(408), 1, 2, 3
MODBUS
eldbus components 3
Modular feedthrough terminal blocks 2
Modular female PCB connectors 2
Modular PCB terminal blocks
fuse terminal blocks, terminal blocks, terminal
blocks for test and measurement 2
f.-e. and s.-e., high-current terminal blocks 2
1-conductor 2
2-conductor 2
Modular terminal blocks and terminal strips
see terminal strips and modular terminal blocks
see PCB terminal blocks
Modular test plug adapters see Test plug adapters
Modular WAGO-I/O-SYSTEM 750 3
Module in DIN-rail mount enclosure
- Manual control module 4(173)
- Radio switching receiver 4(172)
- Switching relay 4(152-159)
- for building custom circuits 4(382)
Modules for self-assembly 4(215)
Mounting adapter
222 Series 1
243 Series 1
273 Series 1
773 Series 1
2273 Series 1
Mounting carrier for MULTI CONNECTION
SYSTEM 2
Mounting carrier
for isolated mounting on carrier rails 1
Mounting carriers and feet for snap-t mounting to
PCBs 4(386-387)
Mounting carriers for DIN-rail mounting PCBs
4(384-385)
M
Mounting plates, for WINSTA
distribution
connectors
- MINI 5
- MIDI 5
- IDC 5
MULTI CONNECTION SYSTEM MICRO 100%
protected against mismating, pin spacing
- 2.5mm 2
- 2.5mm press-in technology 2
- 2.5mm reow soldering 2
MULTI CONNECTION SYSTEM MIDI 100%
protected against mismating, pin spacing
- 5mm 2
- 5mm press-in technology 2
- 7.5mm 2
MULTI CONNECTION SYSTEM MIDI Classic, pin
spacing
- 5mm, 5.08mm 2
- 5mm reow technology 2
- 7.5mm, 7.62mm 2
- 7,5 mm reow technology 2
MULTI CONNECTION SYSTEM MINI 100% protec-
ted against mismating, pin spacing
- 3.5mm 2
- 3.5mm press-in technology 2
- 3.5mm reow soldering 2
- 3.81mm 2
- 3.81mm press-in technology 2
- 3.81mm reow soldering 2
- MINI HD 2
- MINI HD reow soldering 2
MULTI CONNECTION SYSTEM, accessories 2
Multifunction timing relay 4(127)
Multilevel installation terminal blocks
TOPJOB
see ZKGT
TOPJOB
S 1
Multilevel PCB terminal strips, double-deck,
triple-deck, quadruple-deck terminal strips 2
Multilevel terminal blocks
see multilevel installation terminal blocks
Double-deck, triple-deck, quadruple-deck terminal
blocks 1
TOPJOB
S 1
Multi-port device taps for DeviceNet 3
Multirange timing relay, pluggable 4(126)
N
NAMUR switching amplier modules 4(138)
N-conductor disconnect terminal blocks
TOPJOB
1
TOPJOB
S 1
Neon indicator modules, plugable 1
O
OPC server for MODBUS-/TCP 3
Operating lever 2
Operating stickers 1, 2
Operating tool 4(414), 1, 2, 3, 5
TOPJOB
1
TOPJOB
S 1
Optocoupler modules
- Rail-mounted terminal block 4(39-47)
- pluggable 4(128-135)
Order form available on request
10
442
Catalog Catalog Catalog
Catalog (Page) Catalog (Page) Catalog (Page)
P
Parameterization les
see Conguration les 3
Parameterizing software 4(236)
Patching systems
Common potential matrix 1
Terminal blocks for matrix patching (3-conductor
double potential terminal blocks) 1
Terminal blocks for matrix patching and common
potential terminal blocks (4-level terminal blocks,
8-level terminal blocks) 1
Matrix patchboards with CAGE CLAMP
connection 1
PCB terminal blocks 2
PERSPECTO 3
Phase selection
WINSTA
MIDI
WINSTA
MIDI 5
WINSTA
IDC 5
Pin modules for rail-mounted terminal blocks for
Wire-Wrap
and Thermi-Point
1
Plotters and accessories 4(Section 8), 1, 3
Pluggable fuse modules
- for carrier terminal blocks 1
- for double-deck, triple-deck terminal blocks 1
Pluggable wiring 3
Plugs
WINSTA
MINI 5
WINSTA
MIDI 5
WINSTA
MAXI 5
WINSTA
KNX 5
- MULTI CONNECTION SYSTEM 2
X-COM
-SYSTEM 1
Plugs for elevator shaft technology 2
POWER CAGE CLAMP termination 1
TOPJOB
S 1
TOPJOB
1
TOPJOB
S 1
Power supplies
- DIN-rail-mountable 4(Section 4), 3
- Constant voltage sources 4(342-343), 3
- Power supplies, DIN-rail-mountable
4(344-347), 3
- Power supplies, in shielded-metal housing
4(284-321), 3
Power supply connectors 1
Press-in technology
PCB terminal blocks 2
MULTI CONNECTION SYSTEM, 3.5mm, 3.81mm,
5mm
Primary switch mode power supply units
4(Section 4), 3
Printers and accessories 4(400-406), 1, 3
PROFIBUS eldbus components 3
PROFINET eldbus connectors 3
PROFINET I/O eldbus components 3
PROFIsafe, safety modules 3
Programmable eldbus controllers 3
Programming interface, wireless 3
ProServe
connection 1
PUSH WIRE
S 1
Q
Quadruple-deck terminal strips for PCBs 2
Quadruple-deck, rail-mounted terminal blocks for fast
electric motor wiring 1
TOPJOB
S 1
R
Radio adapter 3
Radio receiver in DIN-rail mountable enclosure
4(372), 3
Radio receiver in WINSTA
box 3
Radio receiver module 3
Rail end cap, for DIN 35 rail 4(413), 3
Rail-mounted modules for building custom circuits
4(215)
with CAGE CLAMP
connection 1
with CAGE CLAMP
S connection 1
with FIT CLAMP
(IDC) connection 1
with coupler function 4()
with overvoltage protection 4(Section 5)
for building custom circuits 4(Section 7)
with POWER CAGE CLAMP connection 1
Rail-mounted terminal blocks for fast electric motor
wiring (quadruple-deck) 1
TOPJOB
S 1
Railway applications 4(48, 150)
Reel (THR)
- PCB 2
- MCS 2
Reow soldering: MULTI CONNECTION SYSTEM 2
- 2.5mm 2
- 3.5mm/3.81mm 2
- 5mm 2
- 7,5 mm 2
Reow soldering: PCB terminal blocks 2
Relay modules
- in DIN-rail mount enclosure 4(152-159)
- terminal blocks 4(32-49)
- with miniature relay 4(50-91)
- DIN-rail-mountable 4(Section 1)
- pluggable 4(112-127)
Relay output module 3
Relay socket
- DIN-rail-mountable
- with miniature relay
Repeater power supply 3
Repeater power supply, HART 4(230-231)
Resettable fault indication modules
- pluggable 4(148-149)
Resistance sensors 3
Resistive temperature device (RTD) input module 3
Resistor bridges (strain gauge) 3
Resistor gate modules
- DIN-rail-mountable 4(214)
Ribbon cables 5
RJ-45 connection 4(204-205), 3
RJ-45 connectors 3
RJ-45 interface module 4(204-205)
RS-232 serial interface 3
RS-485 serial interface 3
RTC module 3
S
S0 optocoupler modules 4(136)
S0 supply modules 4(137)
S
Safety modules 3
Sales worldwide 1, 2, 3
Same potential terminal blocks and terminal blocks
for matrix patching, 4-level terminal blccks, 8-level
terminal blocks 1
SCHUKO, see WINSTA
MINI 5
- WINSTA
MIDI 5
Shield connecting system,
shield clamping saddle 4(390-393), 1, 3
Shield terminal blocks
- angled type 1
TOPJOB
5
Siemens-SIMATIC 4(232-233)
Signal splitter 4(232-233)
Snap-in connectors, WINSTA
- MINI 5
- MIDI 5
Snap-in mounting feet, MCS-MIDI Classic
- 5/5.08mm 2
- 7.5/7.62mm 2
Snap-in mounting feet, MCS-MIDI, 100% protected
against mismating
- 5mm 2
- 7.5mm 2
Socket 4(Section 1)
Sockets
WINSTA
MINI 5
WINSTA
MIDI 5
WINSTA
MAXI 5
WINSTA
KNX 5
Software 1, 2, 3
WAGO SCRIPT 2
WAGOframe 4(268), 2, 3
Software tool 3
Solder pin strips 2
Solid state relays 4(Section 1, )
Spacer of same shape 1, 2
Spacers 2
Spacers for sensor and actuator
terminal blocks 1
Specialty I/O modules 3
Specications IEC/EN 4(428-431), 1, 2, 3
Specications UL - Underwriters Laboratories USA
- Tests and test procedures per UL standards 1, 2
10
443
10
Catalog
Catalog (Page)
Catalog Catalog
1 = Full Line Catalog Volume 1 (Rail-Mounted Terminal Block Systems), 2 = Full Line Catalog Volume 2 (Connectors and PCB Terminal Blocks)
3 = Full Line Catalog Volume 3 (I/O-SYSTEM), 4 = Full Line Catalog Volume 4 (Interface Modules), 5 = Full Line Catalog Volume 5 (WINSTA
)
f.-e. = front-entry, s.-e. = side-entry
Catalog (Page) Catalog (Page)
Catalog (Page)
S
SPEEDWAY 3
SSI transmitter interface 3
Staggered jumpers for rail-mounted terminal blocks 1
TOPJOB
S 1
Star point jumpers 1
Step-down jumpers for through terminal blocks
- f.-e. 1
- s.-e. 1
TOPJOB
S 1
Stepper controller 3
Stepper module 3
Strain relief housings
for MCS-MINI 2
for MCS-MIDI 2
for WINSTA
- MINI 4(), 5
- MIDI 5
Strain relief plates
for MCS-MICRO 2
for MCS-MINI / MINI HD 2
for MCS-MIDI 2
for MULTI CONNECTION SYSTEM MICRO, MIDI,
MINI
for 294 Series 1
Stripping knife for at cables 5
Stripping tools 4(416), 1, 2, 3, 5
Subsidiaries and representatives,
WAGO worldwide 4(452-453), 1, 2, 3, 5
Supply module 3
Supply module, WINSTA
IDC 5
Supply modules
see power supply modules
Supply terminal blocks,
ground terminal block
TOPJOB
1
TOPJOB
S 1
N-conductor disconnect terminal blocks
TOPJOB
1
TOPJOB
S 1
Surge suppression devices
- Rail-mounted terminal blocks 4(362-367)
- pluggable 4(362-367)
Switchgear cabinet drawer 1
Switchgear cabinet socket 1
Switching modules 4(159)
- pluggable 4(139)
Switching modules, changeovers, pluggable 4(139)
Switching relay modules
- in rail-mounted terminal blocks
- in DIN-rail-mount enclosure
- DIN-rail-mountable
- pluggable
System I/O modules 3
System wiring 4(191-202), 3
T
T marker tag 1
Tape (THR)
- PCB 2
- MCS 2
Tap-o modules
WINSTA
IDC 5
T-distribution connector
- WINSTA
MINI 5
- WINSTA
MIDI 5
- WINSTA
KNX 5
Technical information
general 1, 2, 3, 5
T
Technical information
hazardous areas 1, 3
for use with miniature metric fuses 1
Technical support 3
Telecontrol technology 3
Telecontroller 3
Temperature range, extented 4(48, 150), 3
Temperature transducer modules 4(272-276)
Temperature transducers 4(238-251)
Terminal block marking 1, 2
Terminal blocks and terminal strips with xing anges
or snap-in mounting feet 1
- f.-e. 1
- s.-e. 1
Terminal blocks for PCBs 2
Terminal blocks for pluggable modules, f.-e.
4(, , , 378-379)
- f.-e. 1
- s.-e. 1
Terminal strips for electrical devices 1
Terminal strips for PCBs
with locking slide, 2
Double-deck terminal strips, 2
Triple-deck terminal strips, 2
Quadruple-deck terminal strips, 2
f.-e. and s.-e., 2
for press-in technology, 2
for reow soldering, 2
High-current terminal strips, 2
with nger operated levers, 2
2-conductor 2
Test pin 2
Test plug adapters for
255, 256, 257 Series PCB terminal blocks 2
MULTI CONNECTION SYSTEM 2
Test plug modules for 2
translate 2
Testboy 4(), 1, 2, 3
Tests and testing procedures 1, 2
Electrical tests, environmental tests, mechanical
tests, material tests 2
Thermal transfer printers 4(401), 1, 3
Thermocouple 3
Threaded anges
- MINI 2
- MIDI 2
- MINI HD 2
Threshold value switch 4(260-261)
Through terminal blocks with insulation displacement
connection (FIT CLAMP
) 1
Through terminal blocks, f.-e.
- angled type 1
for transformer circuits 1
suitable for fuse terminal blocks for automotive
blade-style fuses 1
TOPJOB
S 1
TOPJOB
S 1
Through terminal blocks, miniature for DIN 15 rail
and DIN 35 rail 1
Through terminal blocks, s.-e. 1
High-current through terminal blocks 1
Time delay relay modules
- pluggable 4(122-127)
Tools 4(414-417), 1, 2, 3, 5
T
TO-PASS
3
TOPJOB
connection
Through terminal blocks 1
N-conductor disconnect terminal blocks 1
Power distribution disconnect terminal blocks 1
Shield (screen) terminal blocks 1
Ground conductor terminal blocks 1
Tools 1
TOPJOB
S connection
Diode and LED terminal blocks 1
Double-potential terminal blocks 1
Double-deck terminal blocks 1
Triple-deck terminal blocks 1
Through terminal blocks 1
Multilevel installation terminal blocks 1
N-conductor disconnect terminal blocks 1
Power distribution disconnect terminal blocks 1
Test plug adapter 1
Ground conductor terminal blocks 1
Disconnect terminal blocks for test and measure-
ment 1
Fuse terminal blocks 1
Fuse plugs 1
Fuse disconnect terminal blocks with
pivoting fuse holder 1
Connectors 1
Supply terminal blocks for distribution boxes 1
Touch monitor 3
Training 4(436-437), 3
Transducers 4(Section 3)
Transverse switching terminal blocks 1
Triple-deck installation terminal blocks
see TOPJOB
Triple-deck terminal blocks, f.-e. 1
TOPJOB
S 1
diode terminal blocks, LED terminal blocks
TOPJOB
S 1
Triple-deck terminal strips for PCBs 2
TTY interface 3
U
UL specications - Underwriters Laboratories USA
1, 2
Up/down counters 3
User manual on eldbus components 3
V
Variable resistor terminal blocks, f.-e. 1
Vertically movable marking system 1
Vibration velocity/bearing condition monitoring 3
Visu Panel 3
Voltage sources, constant 4(342-343), 3
Voltage tester 4(418-419), 2, 3
W
WAGO
- worldwide 4(452-453), 1, 2, 3, 5
WAGO ProServe 4(Section 8), 1, 3
WAGO CAGE CLAMP
connection 1, 2, 3
WAGO CAGE CLAMP
S connection 1, 2, 3
10
444
Catalog Catalog Catalog
Catalog (Page) Catalog (Page) Catalog (Page)
W
WAGO online 3
WAGO OPC 3
WAGO ribbon cables 4(Section 1), 3
WAGO services 1, 3
WAGO SPEEDWAY 3
WAGOframe 4(268), 3
WAGO-I/O-CHECK 3
WAGO-I/O-IPC 3
WAGO-I/O-PRO 3
WAGO-USB-Service-Cable 4(269), 3
WCB Combi marking system 1
Web Panel 3
WFB Continuous marking strips 1
WINSTA
5
WINSTA
S 1
Wire marking 4(410-411), 1, 3
Wireless technology 3
Wire-tap branch connectors
for ex. in elevator shaft technology 2
Wiring aid, WINSTA
5
Wiring, pluggable 3
WMB Inline 4(408), 1, 3
WMB Multi marking system 4(408), 1, 2, 3
WSB Quick marking system 4(408), 1, 2
X
X-COM
S-SYSTEM
Carrier terminal blocks 1
Female plugs with
CAGE CLAMP
S connection 1
X-COM
-SYSTEM
- Carrier terminal blocks 1
- Female plugs with
CAGE CLAMP
connection 1
- Male connectors with
CAGE CLAMP
connection 1
- Headers with solder pins 1
10
445
10
Item no. Page Item no. Page Item no. Page Item no. Page
206 Series
206-118 417
206-124 416
206-125 416
206-126 416
206-127 416
206-128 416
206-170 415
206-171 415
206-173 415
206-174 415
206-204 417
206-216 417
206-501 416
206-502 416
206-503 416
206-804 419
206-806 418
206-807 418
206-808 418
206-810 419
206-811 419
206-815 419
209 Series
209-109 413
209-112 90
209-119 386
209-120 386
209-188 386
209-501 379
209-501/000-002 408
209-501/000-005 408
209-501/000-006 408
209-501/000-007 408
209-501/000-012 408
209-501/000-017 408
209-501/000-023 408
209-501/000-024 408
209-552 137
209-601 151
209-682 151
209-685 151
209-686 151
209-690 151
209-691 151
209-692 151
209-693 151
209-701 151
209-701/000-002 151
209-701/000-005 151
209-701/000-006 151
209-701/000-007 151
209-701/000-012 151
209-701/000-017 151
209-701/000-023 151
209-701/000-024 151
209-702 151
209-782 151
209-783 151
209-784 151
209-787 151
209-789 151
209-951 151
209-952 151
209-953 151
209-954 151
209-955 151
209-957 151
209-994 151
209-995 151
209-996 151
209-997 151
210 Series
210-110 49
210-112 412
210-113 412
210-114 412
210-115 412
210-118 412
210-133 393
210-148 412
210-149 412
210-196 412
210-197 412
210-492 379
210-504 412
210-505 412
210-506 412
210-508 412
210-533 384
210-620 383
210-647 414
210-648 414
210-657 414
210-658 414
210-701 403
210-703 403
210-704 403
210-705 403
210-705/000-002 403
210-706 403
210-706/000-002 403
210-707 403
210-707/000-002 403
210-708 403
210-710 403
210-719 414
210-720 49
210-721 414
210-722 414
210-732 403
211 Series
211-110 403
211-111 403
211-112 403
211-113 403
211-114 403
211-115 403
211-120 403
211-121 403
211-122 403
211-123 403
211-124 403
211-125 403
211-129 403
211-135 403
211-150 403
211-151 403
211-155 403
211-156 403
211-161 403
211-162 403
211-211 403
211-611 402
211-612 402
211-613 402
211-614 402
211-615 402
216 Series
216-542 91
248 Series
248-450 49
248-451 49
248-452 49
248-453 49
248-454 49
248-455 49
248-501 49
248-502 49
248-503 49
248-504 49
248-505 49
248-506 49
248-566 49
249 Series
249-116 413
249-117 413
249-606 151
249-607 151
249-608 151
249-622 151
249-623 151
249-651 151
249-653 151
249-654 151
249-656 151
258 Series
258-139 406
258-140 406
258-141 406
258-143 402
258-144 402
258-145 402
258-146 406
258-147 406
258-149 402
258-150 402
258-157 402
258-161 402
258-162 402
258-166 402
258-169 402
258-171 402
258-173 402
258-177 402
258-178 402
258-200 405
258-226 406
258-227 406
258-228 406
258-229 406
258-298 401
258-326 406
258-327 406
258-328 406
258-329 406
258-342 402
258-343 401
258-350 404
258-361 407
258-362 407
258-363 407
258-364 407
258-365 407
258-366 407
258-367 407
258-368 407
258-369 407
258-370 407
258-371 407
258-372 407
258-373 407
258-374 407
258-375 407
258-377 407
258-378 407
258-379 407
258-380 407
258-381 407
258-382 407
258-383 407
258-387 407
258-388 407
258-389 407
258-390 407
258-391 407
258-392 407
258-393 407
258-394 407
258-396 407
258-397 407
258-398 407
258-399 407
258-410 407
258-426 406
258-426/000-005 406
258-427 406
258-427/000-005 406
258-428 406
258-428/000-005 406
258-429 406
258-429/000-005 406
258-450 404
258-451 404
258-452 406
258-452/000-002 406
258-452/000-003 406
258-452/000-004 406
258-452/000-005 406
258-452/000-007 406
258-452/000-010 406
258-453 406
258-454 407
258-455 407
258-456 407
258-457 406
258-458/000-002 406
258-458/000-004 406
258-470 407
258-471 407
258-472 407
258-473 407
258-6000 400
258-6100 400
Item Number Index)
446
10
Item no. Page Item no. Page Item no. Page Item no. Page
280 Series
280-101 380
280-340 358
280-341 358
280-502/281-582 359
280-502/281-583 359
280-502/281-584 359
280-502/281-585 359
280-502/281-586 359
280-502/281-587 359
280-502/281-588 359
280-502/281-589 359
280-502/281-590 359
280-502/281-591 359
280-502/281-592 359
280-502/281-593 359
280-502/281-594 359
280-502/281-595 359
280-502/281-602 358
280-502/281-603 358
280-502/281-604 358
280-502/281-605 358
280-502/281-606 358
280-502/281-607 358
280-502/281-608 358
280-502/281-609 358
280-502/281-610 358
280-502/281-611 358
280-502/281-612 358
280-502/281-613 358
280-502/281-614 358
280-503/281-579 360
280-503/281-580 360
280-503/281-581 360
280-601 380
280-606 380
280-608 112
280-609 113
280-610 380
280-616 380
280-618 112
280-619 113
280-621 380
280-628 115
280-629 117
280-636 118
280-638 115
280-639 117
280-681 380
280-686 380
280-762 112
280-763 113
280-764 115
280-765 117
280-801 380
280-802 380
280-803 380
280-804 380
280-804/281-419 143
280-833 380
280-901 380
280-916 380
286 Series
286-110 378
286-111 378
286-112 378
286-113 378
286-302 113
286-303 113
286-304 113
286-304/004-000 150
286-305 113
286-306 113
286-307 113
286-307/004-000 150
286-308 113
286-310 115
286-311 115
286-312 115
286-312/004-000 150
286-313 115
286-314 115
286-315 115
286-316 115
286-318 116
286-319 116
286-320 116
286-320/004-000 150
286-321 116
286-322 116
286-324 116
286-326 116
286-327 116
286-328 116
286-328/004-000 150
286-329 116
286-330 116
286-332 116
286-334 117
286-335 117
286-336 117
286-336/001-000 150
286-337 117
286-338 117
286-339 117
286-342 117
286-343 117
286-344 117
286-344/004-000 150
286-345 117
286-346 117
286-347 117
286-350 118
286-351 118
286-352 118
286-352/004-000 150
286-353 118
286-354 118
286-355 118
286-364 112
286-364/004-000 150
286-365 112
286-366 112
286-368 112
286-369 112
286-370 112
286-375 118
286-376 119
286-380 121
286-381 121
286-384 119
286-394 114
286-394/004-000 150
286-395 114
286-426 123
286-427 123
286-428 123
286-440 124
286-442 124
286-444 124
286-446 124
286-448 124
286-450 124
286-460 125
286-462 125
286-464 125
286-470 125
286-472 125
286-474 125
286-502 113
286-503 113
286-504 113
286-505 113
286-506 113
286-507 113
286-508 113
286-510 115
286-511 115
286-512 115
286-513 115
286-514 115
286-515 115
286-516 115
286-520 116
286-536 117
286-540 117
286-544 117
286-547 117
286-548 117
286-552 118
286-555 118
286-556 118
286-564 112
286-566 112
286-567 112
286-568 112
286-570 121
286-571 121
286-578 118
286-579 118
286-594 114
286-600 122
286-602 122
286-604 122
286-604/004-000 150
286-610 122
286-612 122
286-614 122
286-616 126
286-640 127
286-640/004-000 150
286-659 140
286-661 140
286-662 141
286-664 141
286-665 141
286-681 148
286-683 149
286-684 148
286-700 128
286-701 128
286-702 128
286-704 129
286-706 129
286-708 129
286-720 130
286-721 130
286-723 131
286-725 133
286-726 132
286-728 132
286-730 132
286-732 132
286-733 132
286-734 132
286-740 136
286-740/001-000 136
286-741 136
286-742 137
286-750 128
286-751 128
286-752 128
286-752/002-000 131
286-754 129
286-756 129
286-758 129
286-790 135
286-791 133
286-792 134
286-794 134
286-803 145
286-805 145
286-807 145
286-809 145
286-813 145
286-815 145
286-817 145
286-819 145
286-822 146
286-825 147
286-826 146
286-830 142
286-831 365
286-832 366
286-833 364
286-834 364
286-834/024-000 365
286-835 362
286-835/115-000 362
286-836 362
286-838 363
286-838/115-000 363
286-840 142
286-841 366
286-842 366
286-843 366
286-844 366
286-860 272
286-860/000-300 275
286-860/150-030 274
286-861 272
286-861/000-300 275
286-861/150-030 274
286-862 272
286-862/000-300 275
286-862/150-030 274
286-863 273
286-864 273
286-865 273
286-866 273
286-867 273
286-868 273
286-870 272
286-870/000-300 275
286-870/150-030 274
286-871 272
286-871/000-300 275
286-871/150-030 274
286-872 272
286-872/000-300 275
286-872/150-030 274
286-873 276
286-874 276
286-875 276
286-880 138
286-881 138
286-890 144
286-891 144
286-895 139
286-896 139
286-904 120
286-906 120
286-906/004-000 150
286-938 135
447
10
10
Item no. Page Item no. Page Item no. Page Item no. Page
287 Series
287-474 107
287-475 106
287-774 103
287-804 104
287-814 104
287-824 104
287-834 104
287-853 105
287-854 105
288 Series
288-001 110
288-002 110
288-003 386
288-111 110
288-112 110
288-113 110
288-131 110
288-132 110
288-133 110
288-151 111
288-152 111
288-153 111
288-304 101
288-312 102
288-320 106
288-364 100
288-368 100
288-380 107
288-412 109
288-413 109
288-414 109
288-415 109
288-416 109
288-418 109
288-422 109
288-423 109
288-424 109
288-425 109
288-426 109
288-428 109
288-435 108
288-437 108
288-504 101
288-508 101
288-512 102
288-554 101
288-564 100
288-565 100
288-567 100
288-568 100
288-600 384
288-601 384
288-602 384
288-620 385
288-621 385
288-622 385
288-626 385
288-627 385
288-758 102
288-761 102
288-762 102
288-800 342
288-801 343
288-808 345
288-809 344
288-810 344
288-812 346
288-813 345
288-814 346
288-815 346
288-816 347
288-824 351
288-895 350
289 Series
289-101 210
289-102 215
289-103 210
289-105 211
289-111 212
289-113 214
289-114 214
289-121 212
289-131 215
289-151 213
289-172 205
289-174 206
289-175 206
289-176 205
289-177 204
289-178 204
289-201 213
289-202 213
289-401 185
289-402 185
289-403 185
289-404 185
289-405 185
289-406 185
289-407 185
289-408 185
289-409 185
289-422 187
289-423 187
289-424 187
289-425 187
289-426 187
289-427 187
289-430 188
289-431 188
289-434 186
289-436 186
289-440 176
289-441 176
289-442 176
289-443 176
289-444 176
289-445 176
289-446 176
289-447 176
289-448 176
289-449 176
289-450 178
289-451 178
289-452 178
289-453 178
289-454 178
289-455 178
289-456 178
289-457 178
289-458 178
289-459 178
289-501 185
289-502 185
289-503 185
289-504 185
289-505 185
289-506 185
289-507 185
289-508 185
289-509 185
289-510 185
289-522 188
289-523 189
289-526 188
289-527 189
289-531 189
289-540 177
289-541 177
289-542 177
289-543 177
289-544 177
289-545 177
289-546 177
289-547 177
289-548 177
289-549 177
289-550 179
289-551 179
289-552 179
289-553 179
289-554 179
289-555 179
289-556 179
289-557 179
289-558 179
289-559 179
289-575 180
289-576 180
289-577 180
289-578 180
289-585 180
289-586 180
289-587 180
289-588 180
289-611 184
289-612 184
289-613 184
289-614 184
289-615 184
289-616 184
289-617 184
289-618 184
289-619 184
289-620 181
289-621 181
289-623 181
289-624 181
289-650 182
289-652 182
289-664 208
289-665 208
289-666 208
289-667 209
289-671 209
289-680 192
289-681 192
289-682 193
289-683 193
289-684 194
289-685 194
289-686 195
289-687 195
289-720 183
289-721 183
289-722 183
289-723 183
289-725 183
289-726 183
289-727 183
289-728 183
289-822 190
289-907 342
289-913 350
289-965 164
289-966 164
704 Series
704-5003 202
704-5004 199
704-5013 202
704-5014 199
704-5024 198
704-5034 199
704-5044 198
704-5054 200
704-5064 201
704-5074 200
706 Series
706-100/1300-200 66
706-100/1301-200 67
706-100/1303-200 67
706-100/1602-200 66
706-3057/300-100 203
706-3057/300-200 203
706-3057/300-300 203
706-753/300-100 64
706-753/300-200 64
706-753/300-300 64
706-753/301-100 64
706-753/301-200 64
706-753/301-300 64
706-7753/302-100 203
706-7753/302-200 203
706-7753/304-100 65
706-7753/304-200 65
706-7753/304-300 65
706-7753/306-100 65
706-7753/306-200 65
706-7753/306-300 65
709 Series
709-118 403
709-119 403
709-120 403
709-177 402
709-178 402
709-196 384
709-198 384
709-350 393
709-352 393
750 Series
750-923 268
758 Series
758-910 374
758-912 374
758-940/001-000 374
758-940/002-000 374
758-940/003-000 374
758-940/004-000 374
759 Series
759-370 268
770 Series
770-103 373
770-113 373
770-114 373
770-629/101-000 373
770-629/102-000 373
Item Number Index
16 Bit)
448
10
Item no. Page Item no. Page Item no. Page Item no. Page
786 Series
786-101 378
786-102 378
786-103 378
786-301 278
786-302 278
786-303 278
786-304 279
786-305 279
786-306 279
786-307 279
786-308 279
786-309 279
786-321 278
786-322 278
786-323 278
786-324 280
786-325 280
786-326 280
786-337 280
786-338 280
786-339 280
787 Series
787-1001 284
787-1002 287
787-1011 285
787-1012 288
787-1021 286
787-1022 289
787-1664 331
787-1668 332
787-1675 321
787-601 310
787-602 313
787-611 311
787-612 314
787-613 317
787-621 312
787-622 315
787-623 318
787-632 316
787-633 319
787-692 320
787-712 290
787-722 291
787-732 292
787-818 296
787-819 293
787-821 294
787-822 297
787-831 295
787-832 298
787-833 300
787-834 299
787-835 301
787-840 302
787-842 303
787-844 304
787-845 305
787-847 306
787-850 307
787-852 308
787-854 309
787-860 328
787-861 330
787-862 329
787-870 322
787-871 325
787-872 326
787-873 327
787-875 323
787-876 324
787-880 334
787-881 335
787-885 336
787-886 337
787-890 338
787-895 339
787-896 340
787-897 341
788 Series
788-100 89
788-101 89
788-102 89
788-103 89
788-113 90
788-114 90
788-115 90
788-116 90
788-117 90
788-120 90
788-121 90
788-122 90
788-123 90
788-124 90
788-125 90
788-150 86
788-152 86
788-154 86
788-155 87
788-156 86
788-157 87
788-158 86
788-160 86
788-162 86
788-164 86
788-166 86
788-168 86
788-170 86
788-172 86
788-174 86
788-175 87
788-176 86
788-177 87
788-178 86
788-179 87
788-180 86
788-181 87
788-182 88
788-183 88
788-184 88
788-185 88
788-186 88
788-187 88
788-188 88
788-189 88
788-190 88
788-191 88
788-192 88
788-193 88
788-303 72
788-304 72
788-305 72
788-306 72
788-307 72
788-311 72
788-312 72
788-313 72
788-314 72
788-315 72
788-324 76
788-334 76
788-341 82
788-342 82
788-344 82
788-346 82
788-347 82
788-349 82
788-354 78
788-355 79
788-384 80
788-404 74
788-412 74
788-506 73
788-507 73
788-508 73
788-512 73
788-515 73
788-516 73
788-528 77
788-538 77
788-541 83
788-543 83
788-544 83
788-546 83
788-548 83
788-549 83
788-607 75
788-608 75
788-615 75
788-616 75
788-700 84
788-701 84
788-720 85
788-721 85
789 Series
789-112 162
789-120 382
789-122 382
789-124 382
789-126 382
789-127 382
789-128 382
789-129 382
789-130 382
789-131 382
789-132 382
789-133 382
789-134 382
789-1341 156
789-1346 156
789-1544 157
789-1549 157
789-304 152
789-312 153
789-313 153
789-315 153
789-323 159
789-325 160
789-329 161
789-336 155
789-352 154
789-504 152
789-508 152
789-512 153
789-515 153
789-516 153
789-535 155
789-536 155
789-551 154
789-552 154
789-570 158
789-571 158
789-601 172
789-602 172
789-620 164
789-621 166
789-622 168
789-652 170
789-810 173
789-811 173
790 Series
790-100 393
790-101 393
790-108 392
790-110 393
790-112 393
790-113 393
790-114 393
790-115 393
790-116 392
790-124 392
790-133 393
790-134 393
790-140 392
790-144 393
790-145 393
790-190 393
790-191 393
790-192 393
790-193 393
790-300 393
790-301 393
791 Series
791-107 392
791-111 392
791-117 392
791-124 392
792 Series
792-800 354
792-801 354
792-802 355
792-803 355
792-804 356
792-805 356
793 Series
793-3501 408
793-4501 408
793-501 71
793-502 71
793-503 71
793-504 71
793-505 71
793-506 71
793-5501 408
793-566 71
807 Series
807-090/101-100 403
449
10
10
Item no. Page Item no. Page Item no. Page Item no. Page
857 Series
857-104 70
857-107 70
857-108 70
857-1330 52
857-1430 60
857-1432 61
857-1494 60
857-150 68
857-152 68
857-153 68
857-155 68
857-157 68
857-161 69
857-162 69
857-164 69
857-165 69
857-167 69
857-168 69
857-303 50
857-304 50
857-305 50
857-306 50
857-307 50
857-308 50
857-314 51
857-317 51
857-318 51
857-354 50
857-357 50
857-358 50
857-364 51
857-367 51
857-368 51
857-400 218
857-401 220
857-402 222
857-409 224
857-411 226
857-412 226
857-413 226
857-414 226
857-415 226
857-416 226
857-420 228
857-421 230
857-423 232
857-450 234
857-451 236
857-452 237
857-500 256
857-531 260
857-550 262
857-552 264
857-704 54
857-707 54
857-708 55
857-714 56
857-717 56
857-718 57
857-724 58
857-727 58
857-728 59
857-800 238
857-801 240
857-809 252
857-810 242
857-811 244
857-818 246
857-819 248
857-820 250
857-979 266
857-980 270
857-981 62
857-982 62
857-986 63
858 Series
858-100 97
858-110 98
858-150 96
858-151 96
858-152 96
858-153 96
858-304 92
858-314 92
858-324 95
858-325 95
858-327 95
858-328 95
858-390 94
858-391 94
858-392 94
858-402 98
858-508 93
858-518 93
858-528 95
859 Series
859-110 381
859-302 32
859-303 32
859-304 32
859-305 32
859-306 32
859-307 32
859-308 32
859-314 33
859-317 33
859-318 35
859-353 32
859-354 32
859-355 32
859-357 32
859-358 32
859-359 34
859-360 34
859-367 35
859-368 36
859-384 48
859-386 48
859-390 36
859-391 37
859-392 38
859-393 48
859-394 48
859-397 48
859-398 37
859-399 48
859-402 49
859-403 49
859-404 49
859-405 49
859-406 49
859-407 49
859-408 49
859-409 49
859-410 49
859-500 49
859-501 381
859-525 49
859-702 44
859-706 45
859-708 44
859-712 43
859-720 41
859-730 42
859-740 42
859-752 45
859-756 46
859-758 46
859-772 43
859-791 39
859-793 39
859-794 41
859-795 40
859-796 40
859-801 348
859-802 348
859-804 349
859-805 349
859-902 47
870 Series
870-518 360
870-519 360
870-523/281-579 360
870-523/281-580 360
870-523/281-581 360
870-523/281-582 361
870-523/281-583 361
870-523/281-584 361
870-523/281-585 361
870-523/281-586 361
870-523/281-587 361
870-523/281-588 361
870-523/281-589 361
870-523/281-590 361
870-523/281-591 361
870-523/281-592 361
870-523/281-593 361
870-523/281-594 361
870-523/281-595 361
2009 Series
2009-110 402
2009-114 402
2009-115 402
2009-135 402
Item Number Index
16 Bit)
10
450
Item no. Page Item no. Page Item no. Page Item no. Page
10
451
10
Argentina
Bruno Schillig S.A.
Arenales 4030, B1604CFD
Florida, PBA
Phone +54 11 4730 1100
Fax +54 11 4761 7244
wago@schillig.com.ar
Australia
Kontact Group
Building Automation & WINSTA Systems
Oce: 730 Springvale Rd
Mulgrave Victoria 3170
P.O. Box 3003, Wheelers Hill VIC 3150
Tel. +61 03 95602757
Fax +61 03 95601727
sales@kontactgroup.com.au
NHP ELECTRICAL ENGINEERING
PRODUCTS PTY LTD
43-67 River Street
Richmond, Victoria, 3121, P.O. Box 199
Phone +61 3 9429 2999
Fax +61 3 9429 1075
export@wago.com
Austria
WAGO Kontakttechnik Ges.m.b.H.
Laxenburger Strae 244
1230 Wien
Phone +43 1 6150780
Fax +43 1 6150775
info.at@wago.com
Azerbaijan
AZ Technics LTD
Zul V. Alizade
Y.Safarov str.33 , AZ1025,
Baku
Republic of Azerbaijan
Tel. +994 12 4968335
Fax +994 12 4968334
info@AZtechnics.az
Belarus
UP FEK
pr-t Pushkina 29-B
220015 Minsk
Phone +375 17 2102189
Fax +375 17 2102189
wago@fek.by
Belgium
WAGO Kontakttechnik
Excelsiorlaan 11
1930 Zaventem
Phone +32 2 7179090
Fax +32 2 7179099
info-be@wago.com
Bosnia and Herzegovina
please contact WAGO Bulgaria
Brazil
WAGO Eletroeletrnicos Ltda
Rua Amrico Simes 1470
So Roque da Chave
Itupeva SP Brasil 13295-000
Phone +55 11 4591 0199
Fax +55 11 4591 0190
info.br@wago.com
Bulgaria
WAGO Kontakttechnik GmbH & Co. KG
Business Center Serdika
2E Akad. Ivan Geshov Blvd.
Building 1, Floor 4, Oce 417
1330 Soa
Phone +359 2 489 46 09
Fax +359 2 928 28 50
info-BG@wago.com
Canada
please contact WAGO USA
Chile
Desimat Chile
Av Puerto Vespucio 9670
Pudahuel Santiago
Phone +56 2 7470152
Fax +56 2 7470153
ventaschile@desimat.cl
China
WAGO ELECTRONIC (TIANJIN) Co. LTD
No.5, Quan Hui Road, Wuqing Development Area
Tianjin 301700
Phone +86 22 59617688
Fax +86 22 59617668
info-cn@wago.com
Columbia
T.H.L. Ltda.
Cra. 49 B # 91-33
Bogot
Phone +57 1 621 85 50
Fax +57 1 621 60 28
ventas-thl@thl-ltda.com
Croatia
M.B.A. d.o.o. za trgovinu i zastupanje
Frana Supila 5
51211 Matulji HR
Phone +385 51 275-736
Fax +385 51 275-066
mba@ri.htnet.hr
Croatia
GENERA CTR d.o.o.
- just for automation technology -
Siget 18 b
10020 Zagreb
Phone +385 13647849
Fax +385 13636662
wago@geneza.hr
Czech Republic
WAGO Elektro spol. sr. o.
Rozvodova 1116/36
143 00 Praha 4 - Modany
Phone +420 261 090 143
Fax +420 261 090 144
info.cz@wago.com
Denmark
WAGO Danmark
Filial of WAGO Kontakttechnik GmbH & Co. KG
Lejrvej 17
3500 Vrlse
Phone +45 44 357777
Fax +45 44 357787
salg.dk@wago.com
Ecuador
ECUAINSETEC CIA LTDA
El Zurriago 177 y El Vengador
P.O. Box 17-16-016
Quito
Phone +593 2 2 26 91 48
Fax +593 2 2 46 18 33
g.castro@ecuainsetec.com.ec
Egypt
IBN Engineering Instrumentation & Control
71 a El Shaheed Ahmed Hamdi St.
King Faisal, Giza
Phone +20 2 7214350
Fax +20 2 7221709
sales@ibnengineering.com
Estonia
Eltarko O
Laki 14 - 502
10621 Tallinn
Phone +372 651 7731
Fax +372 651 7786
andres@eltarko.ee
Finland
WAGO Kontakttechnik GmbH & Co. KG
Filial i Finland
Vellamonkatu 30 B
00550 Helsinki
Phone +358 9 7744 060
Fax +358 9 7744 0660
tilaus@wago.
France
WAGO CONTACT SAS
Paris Nord 2
83 Rue des Chardonnerets
B.P. 55065 - Tremblay en France
95947 - ROISSY CDG CEDEX
Phone +33 1 48172590
Fax +33 1 48632520
info-fr@wago.com
Germany
WAGO Kontakttechnik GmbH & Co. KG
Postfach 28 80, 32385 Minden
Hansastrae 27
32423 Minden
Phone +49 571 887-0
Fax +49 571 887-169
info@wago.com
WAGO Kontakttechnik GmbH & Co. KG
Waldstrae 1
99706 Sondershausen
Phone +49 3632 659-0
Fax +49 3632 659-100
info@wago.com
Great Britian
WAGO Limited
Triton Park, Swift Valley Industrial Estate
RUGBY
Warwickshire, CV21 1SG
Phone +44 1788 568008
Fax +44 1788 568050
uksales@wago.com
Greece
PANAGIOTIS SP. DIMOULAS - BIOMAT
DIMOULAS AUTOMATIONS
Kritis Str. 26
10439 Athen
Tel. +30 210 883 3337
Fax +30 210 883 4436
wago.info@dimoulas.com.gr
Hong Kong
National Concord Eng., Ltd.
Unit A-B, 5/F.
Southeast Industrial Building
611-619 Castle Peak Road
Tsuen Wan, N.T.
Phone +852 24292611
Fax +852 24292164
sales@nce.com.hk
Hungary
WAGO Hungria KFT
Ipari Park, Gyr u. 2
2040 Budapest
Phone +36 23 502-170
Fax +36 23 502-166
info.hu@wago.com
Iceland
S. Gudjonsson ehf.
Audbrekku 9-11
202 Kopavogur
Phone +354 520-4500
Fax +354 520-4501
export@wago.com
India
WAGO & CONTROLS (INDIA) LTD.
C-27, Sector-58, Phase-III
Noida-201 301
Gautam Budh Nagar (U.P)
Phone +91 120 2 580409 10
Fax +91 120 2 580081
info@wagoindia.com
Indonesia
please contact WAGO Singapore
Iraq
please contact WAGO Middle East
Iran
Patsa Industry
No. 2 Bahar St.
South Shiraz Ave
P.O. Box.: 15875-1698
14369 Tehran
Phone +98 21 88047626
Fax +98 21 88040886
info.uae@wago.com
Ireland
Drives & Controls
Unit F4, Riverview Business Park
Nangor Road
Dublin 12
Phone +353 1 4604474
Fax +353 1 4604507
wago@drivesandcontrols.ie
Israel
Comtel Israel Electronic Solutions Ltd.
Bet Hapaamon
20 Hataas Street
P.O. Box 66
44425 Kefar-Saba
Phone +972 9 76 77 240
Fax +972 9 76 77 243
sales@comtel.co.il
Italy
WAGO ELETTRONICA SRL
Via Parini 1
40033 Casalecchio di Reno (BO)
Phone +39 051 6132112
Fax +39 051 6272174
info-ita@wago.com
Japan
WAGO Co. of JAPAN Ltd.
Nittetsu ND-Tower Building 4F
Kameido 1-5-7
Koto-Ku
Tokyo 136-0071
Phone +81 3 5627 2050
Fax +81 3 5627 2055
info-jp@wago.com
Kazakhsta
TOO INTANT
ul. Muratbaeva, d. 61
050026 Almaty
Phone +7 727 2371492
Fax +7 727 2980151
info@intant.kz
TOO Technik-Trade
ul. i. A. Protosanova, 81
070004 Ust-Kamenogorsk
Phone +7 7232 254064
Fax +7 7232 253251
info@technik.kz
Korea
Mahani Electric Co. Ltd.
792-7 Yeoksam-Dong
Kangnam-Gu, 135-080
Seoul, Korea
Phone +82 2 2194 3300
Fax +82 2 2194 3397
export@wago.com
Kosovo
please contact WAGO Bulgaria
Kuwait
Kuwait Controls Company
Al Sour Street, Above Lufthansa Airline
Safat Kuwait 13062
Phone +965 222 54300
Fax +965 224 33698
info.uae@wago.com
Latvia
INSTABALT LATVIA SIA
Vestienas iela 6
Rga, LV-1035
Phone +371 790 1188
Fax +371 790 1180
info@instabalt.lv
Lebanon
Gemayel Trading & Contracting
Antonins Project
P.O. BOX 70-1096
Antelias, Lebanon
Phone +961 4 521 029
Fax +961 4 521 029
gtc.libanon@gmail.com
WAGO Worldwide Companies and Representatives
452
10
Lithuania
INSTABALT LIT UAB
Savanori 187
Vilnius, 2053
Phone +370 52 322 295
Fax +370 52 322 247
info@instabalt.lt
Luxembourg
please contact WAGO Belgium
Macedonia
please contact WAGO Bulgaria
Malaysia
WAGO Representative Oce Malaysia
No 806, Block A4, Leisure Commerce Square,
No 9, Jalan PJS 8/9, 46150 Petaling Jaya,
Selangor Darul Ehsan, Malaysia
Phone +60 3 7877 1776
Fax +60 3 7877 2776
kian.guan.tan@wago.com
HPH Materials (M) Sdn Bhd
No. 4, Jalan Nilam 1/6
Suban Hi-Tech Industrial Park
40000 Shah Alam
Selangor, D.E. Malaysia
Phone +60 3 5638 2213
Fax +60 3 5638 8213
info@hphmaterials.com
Setia Raya Teknik Sdn. Bhd.
40 & 42 Jalan SS15/4
Subang Jaya, 47500 P.J.
Selangor D.E. Malaysia
Phone +60 3 5633 5511
Fax +60 3 5633 3411
sales@setiaraya.com.my
Mexico
WAGO SA de CV
Av. Del Marques 38 Bodega 3
P. I. Bernardo Quintana
76240 El Marques, Quertaro
Phone +52 442 221 5946
Fax +52 442 221 5063
Toll-Free: 001-800-309-5975
info.mx@wago.com
Netherlands
WAGO Nederland
Laan van de Ram 19
7324 BW Apeldoorn
Phone +31 55 36 83 500
Fax +31 55 36 83 599
info-nl@wago.com
New Zealand
NHP NZ
7 Lockhart Place
Mt Wellington
New Zealand
Phone +64 9 2761967
Fax +64 9 2761992
export@wago.com
Norway
WAGO Norge NUF
Jerikoveien 20
1067 Oslo
Phone +47 22 30 94 50
Fax +47 22 30 94 51
info.no@wago.com
Pakistan
FuziLogiX Automation & Control
Suit No. 14, 5th Floor, Shan Arcade
New Garden Town, Lahore
Pakistan
Phone +92 42 594 1503 - 4
Fax +92 42 585 1431
info@fuzilogix.com
Peru
Desimat Peru
Av. Velasco Astete 2371
Surco Lima
Phone +51 1 2752776
Fax +51 1 2752765
export@wago.com
Philippines
please contact WAGO Singapore
Poland
WAGO ELWAG sp. z o. o.
ul. Pikna 58 a
50-506 Wrocaw
Phone +48 71 3602970
Fax +48 71 3602999
wago.elwag@wago.com
Portugal
MORGADO & CA. LDA - SEDE
Estrada Exterior da
Circunvalao 3558/3560
Apartado 1057
4435 Rio Tinto
Phone +351 22 9770600
Fax +351 22 9770699
export@wago.com
Republic of Moldova
Electroservice Slavinschi T.T.
str. Bolgarskaia 9, oce 6
2001 Kishinev
Phone +373 22 274427
Fax +373 22 224481
es@es.mldnet.com
Romania
WAGO Kontakttechnik GmbH & Co. KG
WAGO Representative Oce Bucharest
Str. Nicolae G. Caraml Nr. 26, Bl. 1D, Et. 3, Ap. 7, Sect. 1, OP52
014144-Bucuresti, Romania
Tel. +40-(0)31 421 85 68
Fax +40-(0)21 232 02 31
info-ro@wago.com
VDR & Servicii srl
Str. Valeriu Branite, nr. 60, ap.1, sector 3
Romania
Phone +40 21 3225074/76
Fax +40 21 3225075
oce@componente-automatizari.ro
Russia
WAGO Kontakt Rus
Gostinichny proezd 4B
127106 Moscow
Russia
Phone +7 495 9874790
Fax +7 495 9874791
info.ru@wago.com
WAGO Branch oce
Ekaterinburg
Phone +7 343 216 3426
WAGO Branch oce
Novosibirsk
Phone +7 383 217 9244
WAGO Branch oce
St. Petersburg
Phone +7 812 312 1918
Saudi Arabia
Ali Zaid Al Quraishi & Partners Electrical Services of S.A.
Al Quraishi Center, King Khalid Street
P.O. Box 7386
Dammam - 31462
Phone +966 3 8351155
Fax +966 3 8352297
info.uae@wago.com
Serbia
please contact WAGO Bulgaria
Tagor Electronic doo
Tihomira Brankovica 21
18000 Nis
Tel. +381 18 575545
Fax +381 18 217125
ana.aleksic@tagor.rs
Singapore
WAGO Electronic Pte Ltd
10 Upper Aljunied Link
#04-04 Johnson Controls Building
Singapore 367904
Phone +65 62866776
Fax +65 62842425
info-sing@wago.com
Slovakia
WAGO Elektrik spol. s r. o
Odborrska 52
83102 Bratislava
Tel. +421 2 4569 2503
export@wago.com
Proelektro spol. s r.o.
Na barine 22
84103 Bratislava Lama
Tel. +421 2 4569 2503
info@wago.sk
Slovenia
GENERA d.o.o.
Prevale 10
1236 Trzin
Phone +386 14393050
Fax +386 14393090
genera@genera.si
IC elektronika d.o.o.
Vodovodna cesta 100
1000 Ljubljana
Phone +386 15680110
Fax +386 15689107
info@ic-elect.si
South Africa
Shorrock Automation (Pty) Ltd
Postnet Suite # 219
Private Bag X 8,Elardus Park
0047 Pretoria
Phone +27 12 4500300
Fax +27 12 4500322
sales@shorrock.co.za
Spain
DICOMAT S.L.
Avda. de la Industria, 36
Apartado Correos, 1.178
28108 - Alcobendas (Madrid)
Phone +34 91 6621362
Fax +34 91 6610089
info@dicomat.com
Sweden
WAGO Sverige
WAGO Kontakttechnik GmbH
Tyskland Filial
Box 639, 17527 Jrflla
Datavgen 9 A, 17543 Jrflla
Phone +46 858410680
Fax +46 858410699
info.se@wago.com
Switzerland
WAGO CONTACT SA
Rte. de lIndustrie 19
Case Postale 168
1564 Domdidier
Phone +41/26 676 75 86
Fax +41/26 676 75 01
info.switzerland@wago.com
Syria
Zahabi Co.
8/5 Shouhadaa St., P.O. Box 8262
Aleppo
Phone +963 21 21 22 235 / 6
Fax +963 21 21 24 768
info.uae@wago.com
Taiwan R.O.C.
WAGO Contact, Ltd.
5F., No.168, Jiankang Rd
Zhonghe City
Taipei County 23585, Taiwan
Phone +886 2 22250123
Fax +886 2 22251511
info.taiwan@wago.com
Thailand
WAGO Representative Oce Thailand
4th Floor, KS Building
213/6-8 Rachada Phisek Road
Ding Daeng Bangkok 10320
Phone +66 2 6935611
Fax +66 2 6935612
wago@asianet.co.th
US Power Distribution Co., Ltd.
4th Floor K.S. Building
213/6-8 Rachada Phisek Road
Ding Daeng, Bangkok 10400
Phone +66 2 2763040
Fax +66 2 2763049
wago@asianet.co.th
Turkey
WAGO Elektronik Sanayi ve Ticaret Ltd. ti.
Yukan Dudullu Mahallesi Bayraktar Bulvan
34775 mraniye - Istanbul
Trkiye
Tel. +90 216 472 1133
Fax +90 216 472 9910
info.tr@wago.com
Ukraine
NPP Logicon
Predslavinskaya street, 39, oce 303
03150 Kiev
Phone +380 44 5228019
Fax +380 44 2611803
info@logicon.ua
OOO Mikropribor
ul. Kotelnikova, 4
03115 Kiev
Phone +380 44 5369386
Fax +380 44 5369387
sales@micropribor.kiev.ua
United Arab Emirates (UAE)
WAGO Middle East (FZC)
SAIF Zone, Q4-282
P.O. Box: 120665
Sharjah, UAE
Phone +971 6 5579920
Fax +971 6 5579921
info.uae@wago.com
USA
WAGO Corporation
N120 W19129 Freistadt Road
Germantown, WI 53022
Phone +1 262 255 6222
Fax +1 262 255 3232
Toll-Free: 1-800 DIN Rail (346-7245)
info.us@wago.com
Venezuela
PETROBORNAS, C.A.
C.C. PLAZA AEROPUERTO - PISO 1 - LOCAL P1 - B - 03
(8015) UNARE - PUERTO ORDAZ - ESTADO BOLVAR
REPBLICA BOLIVARIANA DE VENEZUELA
Tel. +58 286 994 3406
Fax +58 286 994 5249
info@petrobornas.net
Vietnam
please contact WAGO Germany (Minden)
Version: 10/2011
Current addresses at www.wago.com
453
10
10
Notes
454
10
455
10
10
5
1
2
6
6
1
3
8
0
8
8
8
-
6
0
0
4
/
0
3
0
0
-
3
6
0
1
C
a
t
a
l
o
g
I
N
T
E
R
F
A
C
E
E
L
E
C
T
R
O
N
I
C
2
0
1
2
G
B
0
6
/
2
0
1
2
-
0
0
P
r
i
n
t
e
d
i
n
G
e
r
m
a
n
y
S
u
b
j
e
c
t
t
o
d
e
s
i
g
n
c
h
a
n
g
e
s