Pubali Bank Sylhet
Pubali Bank Sylhet
Pubali Bank Sylhet
DHAKA
Electrical Schedule for Renovation work along with all follor of our present premises of Biswanath Branch, Sylhet. (Rate are inclusive all required VAT and IT material cost and carrying expenses etc.) Item No
INTERNAL WIRING 1
Description of Item Providing & laying of following PVC pipe (Aziz / National polyer brand or equivalent product of other reputed manufacturer) embedded in wall/column /ceiling/floor etc. with all accessories, 18 SWG G.P sheet pull box with 3 mm thick ebonite sheet cover, fixing materials etc. as required including mending the damages good. a) Minimum inner dia 20 mm & minimum wall thickness 1.5 mm b) Minimum inner dia 25 mm & minimum wall thickness 1.5 mm c) Minimum inner dia 40 mm & minimum wall thickness 1.9 mm Concealed conduit wiring with the following PVC insulated stranded cable (BYA) & PVC insulated green/white coloured ECC wire (BYA) throughpre-laid PVC conduit complete with 18 SWG GP sheet pull box with 3mm thick ebonite sheet cover, fixing materials, other accessories etc. as required including mending the damages good. All electrical contacts shall be of brass/ copper connected through connector or soldering ( no twisting shall be allowed) and cables shall be manufactured and tested according to relavent IEC/BDS/BS/VDE standards . The work shall be carried out as per direction /approval/ acceptance of the Engineer. Cables manufactured by BRB/ Paradise/Poly/ Supersign / Transcom(Transtec) or equivalent approved by the Engineering-inCharge. a) 1C-2x1.5 sq.mm. (BYA) cable with 1.5 sq.mm (BYA) ECC b) 1C-2x2.5 sq.mm. (BYA) cable with 2.5 sq.mm (BYA) ECC c) 1 C-2x4 sq.mm. (BYA) cable with 4 sq.mm (BYA) ECC d) 1C-2x6 sq.mm. (BYA) cable with 6 sq.mm (BYA) ECC f) 1C-4x6 sq.mm. (BYA) cable with 6 sq.mm (BYA) ECC g) 1C-2x10 sq.mm. (BYA) cable with 10 sq.mm (BYA) ECC h) 1C-4x10 sq.mm. (BYA) cable with 10 sq.mm (BYA) ECC Concealed conduit wiring with the following PVC insulated and sheathed stranded cable (NYY/)/XLPE insulated and PVC sheathed stranded cable(2XY) & PVC insulated green /white coloured ECC wire (BYA) through pre-laid PVC conduit complete with fixing materials other accessories etc. as required including mending the damages good. All electrical contacts shall be of brass/copper connected through connector or soldering ( no twisting shall be allowed) and cables shall be manufactured and ested according to relavent IEC/BDS/BS/VDE standards . The work shall be carried out as per direction/approval/ acceptance of he Engineer.: Cables manufactured by BRB/ Paradise/ Transcom(Transtec) or equivalent approved by the Engineering-in-Charge.
Quantity Unit
Rate in Tk
Amount in Tk
Rate in Tk
Amount in Tk
260 280 45
Rm Rm Rm
30 40 50
15 20 25
Rm Rm Rm Rm Rm Rm Rm
65 95 130 240
15
Rm
7000
105000
15000
225000 0
0 7000
10000 15000
20000 15000 0
20 5
4400 1100
1800 2400
36000 12000 0
4 1
0 5000
5000 6500
20000 6500
Providing & fixing 250 volts. 5/6 amps, (minimum) concealed type following switch / Switch socket manufactured and tested in accordance with relevant IEC/ VDE/NEMA/BS/JIS standards mounted on required size 18 SWG galvanized plain sheet board of 76.2 mm (3") depth. All electrical contacts shall be of brass/copper Gang Switch/ switch socket of MK/MEM/ Legrand/ Schneider/ABB or equivalent approved by the Engineering-in-Charge a) One gang switch (1-way) b) Two gang switch (1-way) c) Three gang switch (1-way) d) Four gang switch (1-way) e) One gang switch & one 5 amps. 2-pin socket combined f) Gang type Fan Regulator with switch g) Gang type Calling bell Push h) 13A, 3-pin combined switch-socket (Flat type pin) i) 15A, 3-pin combined switch-socket (Round type pin) Providing & fixing 250 V grade call bell on board including required length of PVC twin flexible cord, 25 watt bulb, brass batten holder etc. complete. (Local made best quality). Providing & fixing 250 V grade, 8"dia security alarm bell on board including required length of PVC twin flexible cord. The alarm bell will be covered in three sides by 20 SWG G.I sheet. The lower portion of alarm bell will remain open. The G.I sheet cover are to be painted by white colour enamel paint by written Bengali word "Bipad Sankef'at face of G.I sheet cover by red enamel paint etc. all complete as per direction by the Engineer. Providing & fixing of 18 SWG metal clad 500 volt 3 phase two way change-over switch of following capacity complete with moving & fixed copper contacts, copper buses, brass nuts and bolts, 3mm thick ebonite sheet separators insulators, operating handle etc, complete including necessary hammer painting on enclosure, a) 100 Arnps. rating. Earthing the electrical installation with 40 mm. (1.5") dia G.I. pipe (Earth electrode) having 6.35 mm. dia hole across the pipe at 305 mm. interval securedly bonded by soldering with 2 nos.of No2 SWG HDBC earth leads with its protection by 20 mm. (3/4") dia G.I. pipe up-to plinth level run at a depth of 609.6 mm. (2 ft.) below G.L. up-to main board to be earthed including necessary connecting copper sockets, bolts, nuts, etc. complete for maintaining earth resistance within 1 ohm. Depth of bottom of main electrode at 37338 mm. (122.5 ft) from GL & length of electrode 36576 mm. (120 ft). Per set Supplying & fixing AC capacitor type ceiling fan (without regulator) of following specifications and sizes complete with minimum 305 mm. (1 ft) long down rod, aluminum blades, capacitor canopy, (including ceiling rose for connection) etc. connecting PVC wire complete as required . Rated voltage : 220 volts Rated frequency : 50 Hz Rated speed : 300 rpm 10% Input Power : Max 80 watt Service Value : Minimum 2.80 m3/ min/watt Temperatur Rise : Maximum 70C Class of Insulation : Class-E 1422.4 mm. (56") Sweep GEC Delux/ National, tongi or equivalent approved by the Engineering-in-Charge Providing and fixing of following axial flow A.C capacitor type wall mounted exhaust fan complete with blade, steel frame standard wall louver shutter, PVC insulated connecting wire (including ceiling rose for connection) etc complete as required ncluding cutting wall and mending good the damages as per direction of the Engineer-in-charge 10" Exhaust fan plastic body (Foreign made approved by the Engineeringin-Charge) Providing and fixing of wall bracket fan of following sizes complete with blade, frame, built-in regulator, PVC insulated connecting wire (including ceiling rose for connection) etc as required as per direction of the Engineer-in-charge (Foreign made). 12" sweep ( Plastic body and blade ) Providing & fixing U type fan clamp made of 15.87 mm. (5/8") dia MS rod as per sample approved by the Engineer-in-charge. Providing & fixing of 23 watt energy saving lamp on batten type brass holder fitting on 3mm thick ebonite etc. all complete as per direction by the Engineer and sample approved by the Engineer. ENERGY SAVINGS LAMP(CFL) (230V/250V, 50Hz) (Osram/ Philips /Energypac/ Corona/Havells/ GE Edision/ Prodip/ MEP/ Metro /Superstar / Energy or Equivalent approved by the Engineering-in-Charge.) 2 12 7 0 6 2 4 13 1 1 Each Each Each Each Each Each Each Each Each Each
285 400 300 400 500 400 400 400 1000 4000
570 4800 2100 0 3000 800 1600 5200 1000 4000 45000
500 450 950 1050 650 500 500 550 950 1000 1500
1000 5400 6650 0 3900 1000 2000 7150 950 1000 4500
Each 15000
10
set
4000
4000
1500
0 1500
11
Set
100
100
40000
40000
12
Set
4000
8000
13
Set
3500
10500
14
Set
15 16
2 9
Set Set
0 0
500
1000 4950
550
17
Providing & fixing the Concealed type Spot Light fitting of following manufacturers, consisting of min. 120 mm. dia & 184mm height Steel Sheet Carrier (body & arms) with Powder coated Paint & inside powder coated white reflector, E - 27 Holder, Earth terminal, necessary wiring with 2 x 0.4 Sq. mm. Stranded PVC insulated flexible FR Cable etc., suitable for 20/23 watt CFL, Complete (Including Lamp) sample approved by the Engineer. Manufacturere of shade : Gloria lighting / Crescent / Asha / Shwash/ Tachi or Equivalent approved by the Engineering-inCharge. Manufacturers of ENERGY SAVINGS LAMP(CFL) (230V/250V, 50Hz) (Osram/ Philips /Energypac/ Grammen/ Havells/ GE Edision/ Prodip/ MEP/ Metro /Superstar/ Energy or Equivalent approved by the Engineering-in-Charge.) Providing & fixing the 1 x 4' x 40 watt fluorescent tube light itting of following manufacturers, consisting of powder coated 22 SWG sheet steet frame of min. length 1226mm & breadth 60mm, superior quality electronic ballast with one year guarantee, holder, necessary wiring with 2 x 0.4 sq mm PVC nsulated (stranded) flexible FR wire, earth terminal etc. complete (Including lamp) with as per sample approved by the Engineer. Manufacturere of shade : Gloria lighting / Crescent / Asha / Shwash or Equivalent approved by the Engineering-in-Charge.) Providing & fixing the 3X50watt halogen tract light fitting with 3'-O'long track channel, necessary wiring with 2 x 0.4 sq mm PVC insulated (stranded) flexible FR wire, earth terminal etc. complete (Including lamp) with as per sample approved by the Engineer. Manufacturere of shade : Gloria lighting / Crescent / Asha / Shwash or Equivalent approved by the Engineering-in-Charge.)
63
Set
600
37800
18
Set
800
3200
19
Set
4000
8000
Rate in Tk
Amount in Tk
15 20 25
15000
225000 0
10000 15000
20000 15000 0
1800 2400
36000 12000 0
5000 6500
20000 6500
500 450 950 1050 650 500 500 550 950 1000 1500
1000 5400 6650 0 3900 1000 2000 7150 950 1000 4500
1500
0 1500
40000
40000
4000
8000
3500
10500
500
1000 4950
550
600
37800
800
3200
4000
8000