Micro CHP PDF
Micro CHP PDF
Micro CHP PDF
Micro-Combined Heat and Power (Micro-CHP) Appliances for oneor two-family houses for more energy efficiency
Introduction
Klaus Sommer
Ph.D, ASHRAE, REHVA Fellow, VDI Professor at Cologne University of Applied Sciences Klaus.Sommer@FH-Koeln.de
2 - MatriX cylinder burner Modulation range 4.520 kW Nox <40 mg/kWh CO <50 mg/kWh 3 - Air distribution valve
With the transition towards energy supply which has to be based more and more on energy efficiency and CO2 reduction the decentralized energy systems will play an important role now and in the future. In general the combined heat and power (CHP) technology is a wellknown and established engineering solution for energy efficient energy supply. But it is new that the market is getting ready now also for small-sized CHP units for one- or two-family houses as it was presented at this years ISH in Frankfurt/Germany for example under the topic of Micro-CHP appliances. This article describes these appliances only for the three different technologies Stirling Engine, Internal Combustion Engine and Fuel Cell with the help of some product examples.
Stirling Engine
A B
6 - Control
The Viessmann Vitotwin 300-W (Figure 1) is an example for a Micro-CHP appliance with a Stirling engine (Figure 2) which is hermetically sealed and almost maintenancefree. It runs quietly and therefore it allows an installation close to the living space.
C
The gas fired stirling engine generates 6 kW heat with an efficiency of 81% (gross cv) and 1 kW power with an efficiency of 15% (gross cv) simultaneously. The integrated gas fired peak load boiler of the Vitotwin 300-W can generate heat between 6 kW and 20 kW in
A - Hot area, B - Displacer piston, C - Cold area, D - Working piston, E - Power generation, F - Cylinder retriever
Figure 1. Wall mounted Viessmann Vitotwin 300-W Micro-CHP appliance with a Stirling engine (lower half ) and with integral peak load boiler (upper half ). Image source: www.viessmann.com
Figure 2. Hermetically sealed Stirling engine with the heating-up heat exchanger (hot area) and the displacer piston in the upper part, water-cooled heat exchanger (cold area) in the middle part and working, piston, springs (cylinder retriever), coil and magnets (Linear Generator for electrical output) in the lower part. The displacer piston moves the operating gas 50 times per second from the hot to the cold area. The alternately heated and cooled operating gas expands and contracts what creates pressure waves and that then again let the working piston move. The working piston is a part of the linear generator which produces electricity while the working piston is moving. Image source: www.viessmann.com
30
articles
addition with 98% efficiency (gross cv). Therefore this high-efficient Micro-CHP is suitable for old and new detached houses and also for two-family houses. With an annual consumption of gas of 26 000 kWh or more and power consumption above 3 000 kWh per year the Micro-CHP works with exceptional economy. The stirling engine operates in a heat-led mode. The constantly generated power of 1 kW covers the base load of the electricity demand on site and surplus power is exported to the public grid, which is remunerated. Due to the daily fluctuation of the heat consumption on the one hand and the constantly generated heat during the operation of the Micro-CHP on the other hand the combination with a heating water buffer cylinder is essential (Figure 3).
Figure 3. Viessmann Vitotwin 300-W Micro-CHP appliance with a heating water buffer cylinder. Image source: www.Viessmann.com
Figure 4. Gas-Internal Combustion Engine (singlecylinder four-stroke piston engine). Electrical output 1 kW with efficiency of 26.3%, thermal output 2.5 kW with efficiency of 65.7% and total efficiency of 92% (nett cv). Image source: www.Vaillant.com
Figure 5. Components of the Micro-CHP system of Vaillant ecoPower 1.0: wall-mounted gas-fired peak-load condensing boiler (left), Micro-CHP unit and heat-transfer module with system controller (center), multi-function cylinder with 300 liter or 500 liter capacity and external heat exchanger for domestic hot water (right). Image source: www.vaillant.com
31
articles
Figure 6. Comparison between a separated and a micro-combined heat and power generation. Image source: www.ASUE.de
power generation with a coal-fired power plant together with a gas boiler on site and on the other hand there is a micro-CHP on site. In this example it turns out that the micro-CHP appliance can save 30% of the primary energy compared with the low-efficient power plant solution.
32
articles
Figure 8. Functional principle of the high temperature Solid Oxide Fuel Cell (SOFC); source: Ceramic Fuel Cells Limited. Image source: www.cfcl.com.au
ated thermal output up to 1 kW W the total efficiency of the BlueGen can increase above 80%. For this case of operation the CO2-reduction could be 50% and more compared with a separated heat and power generation of average existing energy efficiency.
Ongoing tests just try to find out how far the BlueGen can cover the annual heat consumption and also the annual electrical consumption of single-family or two-family houses in a power-led mode with a peak load boiler and an optimized heating water buffer cylinder in addition (1).
Conclusion
Compared with separately generated heat and power the gas-fired micro-CHP appliances with stirling engine, internal combustion engine or high temperature solid oxide fuel cell save energy and reduce CO2-production for old and new one- or two-family houses. The heat-led Stirling engine and Internal combustion engine are designed for 1 kW electrical output with an electrical efficiency of 15% and 26.3% and CHP-generated thermal output of 2.5 kW or 6 kW. Together with a peak load boiler the thermal output of these appliances varies up to around 28 kW dependent on the chosen performance of the peak load boiler. The high temperature solid oxide fuel cell is designed for power-led operation with a very high electrical efficiency up to 60% and an electrical output up to 2 kW together with a thermal output up to 1 kW.
Sources
(1) Two-year research project (2011-2013) Analyzing of the real operating characteristics of a high-efficient fuel Cell-based MicroCHP in order to find out the best possible application for residential buildings and to get real system characteristics; project leader Klaus Sommer. Funded by Klimakreis Koeln (www.klimakreis-koeln.de), Rheinenergie (www.rheinenergie.com) and Cologne University of Applied Sciences (www.fh-koeln.de).
Figure 9. Hot module of the BlueGen with the high temperature solid oxide fuel cell stack in the upper part. Image source: www.cfcl.com.au
33