Eaton Series G Circuit Breaker
Eaton Series G Circuit Breaker
Eaton Series G Circuit Breaker
Australian Standard AS 2184 and
AS 3947-2 Moulded Case Circuit
Breakers.
British Standards Institution
Standard BS 4752: Part 1, Switch-
gear and Control Gear Part 1,
Circuit Breakers.
International Electrotechnical
Commission Recommendations
IEC 60947.2 Circuit Breakers.
Japanese T-Mark Standard
Moulded Case Circuit Breakers.
National Electrical Manufacturers
Association Standards Publication
No. AB1-1975 Moulded Case
Circuit Breakers.
South African Bureau of Standards,
Standard SABS 156, Standard
Specication for Moulded Case
Circuit Breakers.
Swiss Electro-Technical Association
Standard SEV 947.2, Safety
Regulations for Circuit Breakers.
Union Technique de lElectricite
Standard NF C 63-120, Low Voltage
Switchgear and Control Gear
Circuit Breaker Requirements.
Verband Deutscher Elektrotechnike
(Association of German Electrical
Engineers) Standard VDE 0660,
Low Voltage Switchgear and
Control Gear, Circuit Breakers.
Trademarks
Cutler-Hammer is a federally regis-
tered trademark of Eaton Corporation.
CSA is a registered trademark of
Canadian Standards Association.
UL is a registered trademark of
Underwriters Laboratories Inc.
ISO is the registered trademark and
sole property of the International
Organization for Standardization.
NEMA is the registered trademark and
service mark of the National Electrical
Manufacturers Association.
Global Third Party
Certication
Certication marks ensure product
compliance with the total standard
via the third party witnessing of tests
by globally recognized independent
certication organizations.
KEMA is a highly recognized, indepen-
dent international organization that
offers certication and inspection
facilities for equipment in many
industries. The KEMA-KEUR mark is
the highest certication an electrical
product can receive from KEMA.
Our IEC 60947-2 Moulded Case Circuit
Breakers are KEMA tested and certi-
ed. These breakers are also listed
in accordance with UL
489, as well
as CSA C22.2 No. 5-02.
KEMA and UL provide ongoing
follow-up testing and inspections to
ensure that Eaton Moulded Case
Circuit Breakers continue to meet
their exacting standards.
Note:
The Eaton Series G Frames GE, GJ,
GL, GN and GR, although they are UL and
CSA approved, do not carry the UL and CSA
labels on the breakers. For applications that
require UL/CSA labels, please contact your
Eaton representative.
September 2005
2
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GR (15 2500 Amperes)
Vol. 1, Ref. No. [02]
General Information
Eaton Series G Moulded Case
Circuit Breakers provide increased
performance in considerably less
space than standard circuit breakers
or comparable fusible devices.
The G signies global applications:
Series G circuit breakers are marked
with UL, CSA
, CE, IEC and KEMA
KEUR listings. Other advantages
include:
Field-t accessories.
Common accessories through
630 amperes.
Electronic trip units from 20 to
2500 amperes.
UL-listed and IEC-rated, 30 mA
ground fault/earth leakage modules.
Built-in ground fault protection
down to 20 amperes.
The GE, GJ and GL frames are new
circuit breakers designed around
space-saving footprints. The GN and
GR use the proven Cutler-Hammer
Series C
ND and RD designs but use
metric threading on their line and
load conductors.
Eaton Series G Circuit Breakers meet
applicable UL 489 and IEC 60947-2
standards.
The Eaton Series G family includes
ve frame sizes in ratings from 15 to
2500 amperes. Series G offers a choice
of several interrupting capacities up
to 100 kA at 480 volts ac (200 kA at
240 volts ac).
Standard calibration is 40C. For appli-
cations in high ambient temperature
conditions, 50C factory calibration
is available on thermal magnetic
breakers.
The Most Logically Designed
Contact Assembly
The exibility and outstanding
performance characteristics of Eaton
Circuit Breakers are made possible
by the best contact designs in circuit
breaker history. Our patented technol-
ogy creates a high-speed blow-open
action using the electromechanical
forces produced by high-level
fault currents.
Eaton Circuit Breakers are operated by
a toggle-type mechanism that is
mechanically trip-free from the handle
so that the contacts cannot be held
closed against short circuit currents.
Tripping due to overload or short
circuits is clearly indicated by the
position on the handle. This remark-
ably fast and dependable contact
action is designed to enhance safety.
Thorough In-Plant Testing
The quality, dependability and reliability
of every Eaton Circuit Breaker is
ensured by a thorough program
of in-plant testing. Two calibration
tests are conducted on every pole of
every circuit breaker to verify the trip
mechanism, operating mechanism,
continuity and accuracy.
ISO Certication
Eaton Circuit Breakers are manufac-
tured in ISO
certified facilities.
Current Limiting Characteristics
Eaton Series G Circuit Breakers
are current limiting because of their
high repulsion contact arrangement
and use of state-of-the-art arc
extinguishing technology.
Operating Mechanisms
Eaton Circuit Breakers have a toggle
handle operating mechanism, which
also serves as a switching position
indicator. The indicator shows the
positions of: ON, OFF and TRIPPED.
The toggle handle snaps into the
TRIPPED position if the breaker is
tripped by one of its overcurrent, short
circuit, shunt or undervoltage releases.
Before the circuit breaker can be
reclosed following a trip-out, the tog-
gle handle must be brought beyond
the OFF position (RESET). The circuit
breaker can then be reclosed.
As an additional switching position
indicator for GE- to GR-Frame circuit
breakers, there are two windows on
the right and on the left of the toggle
handle, in which the switching state
is indicated by means of the colors
red, green and white corresponding to
the ON, OFF and TRIPPED positions
respectively.
Figure 1. Positions of the Toggle Handle Drive
OFF
RESET
ON
Tripped
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
3
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GR (15 2500 Amperes)
Vol. 1, Ref. No. [03]
Typical Applications
Machine Tool Control Panels
and Motor Control Centers
Designed for these equipment
requirements, including new
world-class accessories.
Panelboards
As both main and branch circuit
protection devices.
Feeder Pillars
In distribution systems to provide
main and branch circuit protection.
Switchgear
In distribution systems to provide
main and branch circuit protection up
to 2500 amperes (GR-Frame).
Bus Bar Trunking Tap-Offs
In bus bar trunking tap-offs to provide
circuit protection.
Individual Enclosures
Completely assembled in enclosures
to meet specic customer
requirements.
Additional Applications
Special versions of each Cutler-Hammer
frame are available to provide safe
equipment control and protection in
mining and other applications. Contact
your Eaton agent or distributor for
additional information.
Figure 2. Typical Eaton Applications
Table 1. Typical Eaton Applications
125 amperes is the maximum NEMA rating for the GE.
630 amperes is not NEMA rated. 600 amperes is the maximum NEMA rating for the GL.
1200 amperes is the maximum NEMA rating for the GN.
Frame Continuous
Ampere
Rating
Range
Trip Unit Type Moulded
Case
Switch
Adjustable
Thermal
Fixed
Magnetic
Fixed
Thermal
Fixed
Magnetic
Adjustable
Thermal
Adjustable
Magnetic
30 mA
Ground
Fault/Earth
Leakage
Digitrip
RMS
Electronic
Trip Units
E 15 160
J 20 250
L 100 630
N 400 1600
R 800 2500
Switchboard
Machine Tool
Control Panel
Bus Bar
Trunking
Tap-Off
Individual
Circuit
Breaker
Enclosure
Panelboard
September 2005
4
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GL
Vol. 1, Ref. No. [04]
Electrical Characteristics
Table 2. Electrical Characteristics
125 amperes is the maximum NEMA rating for the GE.
630 amperes is not NEMA rated. 600 amperes is the maximum NEMA rating for the GL.
Neutral on left side.
Two poles in series.
Not suitable for dc application. 4-pole ground fault not available with neutral protection.
Maximum Rated Current
(Amperes)
GE GJ GL
125, 160
250 400, 630
Breaker Type B E S H E S H C E S H C
Number of Poles 1 2, 3, 4
2, 3, 4
1 2, 3, 4
1 2, 3, 4
2, 3, 4
3, 4
Breaker Capacity (kA rms) ac 50 60 Hz
NEMA
,
UL, CSA
240 Vac 25 25 35 85 85 100 100 65 85 100 200 65 85 100 200
480 Vac 18 25 35 65 25 35 65 100 35 50 65 100
600 Vac 18 25 35 50 18 25 35 50
250 Vdc
10 10 10 35 35 42 42 10 35 42 42 22 22 42 42
IEC 60947-2 220 240 Vac I
cu 25 25 35 85 85 100 100 65 85 100 200 65 85 100 200
I
cs 25 25 35 43 43 50 50 65 85 100 150 65 85 100 150
380 415 Vac I
cu 18 25 40 70 25 40 70 100 35 50 70 100
I
cs 18 25 30 35 25 40 70 75 35 50 70 75
660 690 Vac I
cu 3 4 6 12 12 14 20 12 20 25 35
I
cs 3 3 3 6 6 7 10 6 10 13 18
250 Vdc
I
cu 10 10 10 35 35 42 42 10 35 42 42 22 22 42 42
I
cs 10 10 10 35 35 42 42 10 35 42 42 22 22 42 42
Ampere Range 15 160 A
20 250 A 100 630 A
Trip Units
F= Fixed
A= Adjustable
T= Thermal
M= Magnetic
FT-FM
AT-FM
FT-AM
AT-AM
Electronic (Digitrip RMS 310)
FT-AM
AT-AM
Electronic (Digitrip RMS 310)
Interchangeable
Built-in
Thermal
Magnetic
Fixed Thermal
Adjustable Thermal
Magnetic Fixed Adjustable Adjustable
Electronic
rms
LS
LSI
LSG
LSIG
Dimensions
mm (Inches)
H W D H W D H W D
1-Pole 139.7
(5.50)
25.4 (1.00) 76.0
(2.99)
2-Pole 50.8 (2.00) 177.8
(7.00)
105.0
(4.13)
87.4
(3.57)
3-Pole 76.2 (3.00) 258.0
(10.13)
140.0
(5.48)
104.0
(4.09)
4-Pole 101.6 (4.00) 135.6
(5.34)
183.0
(7.22)
Weight (approximate) kg (lbs.) 1-Pole 2-Pole 3-Pole 4-Pole 2-Pole 3-Pole 4-Pole 3-Pole 4-Pole
0.5 (1.1) 0.9 (2.0 ) 1.4 (3.1) 1.8 (3.9) 5.2 (11.4) 5.2 (11.4) 7.0 (15.3) 7.3 (16.0) 9.1 (20.0)
Utilization Category A A A
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
5
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GN and GR
Vol. 1, Ref. No. [05]
Table 2. Electrical Characteristics (Continued)
The GN and GR MCCBs use metric threading in their line and load terminals. If English (Imperial) threading is needed, use Series C ND and RD MCCBs.
Contact Eaton for more information.
GN 1600 ampere frame is not NEMA rated.
Not KEMA-KEUR listed.
Neutral on right side.
IEC 60947-2 H.5 Annex H is not KEMA-KEUR tested.
Not suitable for dc application. 4-pole ground fault not available with neutral protection.
Available only on Digitrip 610 and 910 trip units.
Maximum Rated Current
(Amperes)
GN
GR
800, 1250 1600
1600, 2000, 2500
Breaker Type S H C
S H H C
Number of Poles 2, 3, 4
2, 3, 4
3, 4
Breaker Capacity (kA rms) ac 50 60 Hz
NEMA,
UL, CSA
240 Vac 65 100 200 125 200
480 Vac 50 65 100 65 100
600 Vac 25 35 50 50 65
IEC 60947-2 220 240 Vac I
cu 85 100 200 85 100 135 200
I
cs 85 100 100 85 100 100 100
380 415 Vac I
cu 50 70 100 50 70 70 100
I
cs 50 50 50 50 50 50 50
660 690 Vac I
cu 20
25
35 20
25 25
35
I
cs 10 13 18 10 13 13 18
250 Vdc I
cu
I
cs
Ampere Range 400 1250 A 1600 A 800 2500 A
Trip Units Electronic (Digitrip RMS 310) Electronic (Digitrip RMS 310, 610 and 910)
Interchangeable
Built-in
Electronic
LI
LS
LSI
LIG
LSG
LSIG
Dimensions
mm (Inches)
H W D H W D
1-Pole
2-Pole
3-Pole 406.0 (16.00) 210.0 (8.25) 140.0 (5.50) 406.0 (16.00) 394.0 (15.50) 229.0 (9.75)
4-Pole 280.0 (11.13) 508.0 (20.00)
Weight (approximate) kg (lbs.) 3-Pole 4-Pole 3-Pole 4-Pole
21.3 (46.8) 28.3 (62.0) 47.0 (103.0) 54.0 (118.4)
Utilization Category A A
September 2005
6
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GR Vol. 1, Ref. No. [06]
Table 3. GE through GR Electrical Characteristics
630 amperes is not NEMA rated. 600 amperes is the maximum NEMA rating for the GL.
Yes
Yes
Yes
Yes
Permissible Ambient Temperature -20 to +70C -20 to +70C -20 to +70C -5 to +60C -5 to +60C
Permissible Load for Various Ambient Temperatures
Close to the Circuit Breaker, Related to the Rated
Current of the Circuit Breaker
Circuit Breakers for Plant Protection
At 40C
At 50C
At 55C
At 60C
At 70C
100%
96%
93%
91%
86%
100%
92%
87%
83%
73%
100%
96%
94%
92%
88%
100%
94%
90%
87%
80%
100%
96%
93%
90%
84%
100%
91%
86%
82%
70%
100%
91%
85%
81%
100%
91%
85%
81%
100%
100%
100%
100%
90%
100%
100%
100%
100%
90%
100%
91%
85%
81%
5.6 Nm
5.6 Nm
Box Terminals
50 to 150 mm
2
35 to 120 mm
2
20 Nm
15 Nm
Box Terminals
95 to 240 mm
2
70 to 150 mm
2
42 Nm
30 Nm
Flat Bar
Terminals
600 A
31 Nm
6 Nm
Flat Bar Terminals
Optional
31 Nm
50 Nm
Flat Bar Terminals
Optional
20 Nm
Conductor Cross Sections for Auxiliary Circuits
with Terminal Connection or Terminal Strip
Solid
Finely Stranded with End Sleeve
With Brought-out Cable Ends
Tightening Torque for Fitting Screws
0.75 to 2.5 mm
2
0.75 to 2.5 mm
2
0.75 to 2.5 mm
2
0.75 to 2.5 mm
2
0.82 (AWG 18) mm
2
0.8 to 1.4 Nm
0.75 to 2.5 mm
2
0.75 to 2.5 mm
2
0.82 (AWG 18) mm
2
0.8 to 1.4 Nm
Up to 2x4 mm
2
Up to 2x2.5 mm
2
0.82 (AWG 18) mm
2
0.8 to 1.4 Nm
Up to 2x4 mm
2
Up to 2x2.5 mm
2
0.82 (AWG 18) mm
2
0.8 to 1.4 Nm
Power Loss per Circuit Breaker at Maximum
Rated Current l
n
(The Power Losses of the
Undervoltage Releases (r Releases) Must Be
Observed if Necessary) at Three-Phase
Symmetrical Load)
For Plant Protection
As Isolating Circuit Breaker
For Starter Combinations
For Motor Protection
50 W
40 W
40 W
75 W
75 W
45 W
75 W
255 W
160 W
160 W
120 W
87/210 W
87/210 W
220/270/400 W
220/270/400 W
9
0
9
0
9
0
September 2005
8
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GR Vol. 1, Ref. No. [08]
Table 3. GE through GR Electrical Characteristics (Continued)
Technical Data GE GJ GL GN GR
Auxiliary Switches
Rated Thermal Current l
th
Rated Making Capacity
6 A
20 A
6 A
20 A
6 A
20 A
6 A
20 A
6 A
20 A
ac (ac-15)
Rated Operational Voltage
Rated Operational Current
230/400/600 V
6/3/0.25 A
230/400/600 V
6/3/0.25 A
230/400/600 V
6/3/0.25 A
600 V
6 A
600 V
6 A
dc (dc-13)
Rated Operational Voltage
Rated Operational Current
125/250 V
0.5/0.25 A
125/250 V
0.5/0.15 A
125/250 V
0.5/0.15 A
125/250 V
0.5/0.25 A
125/250 V
0.5/0.25 A
Backup Fuse
Miniature Circuit Breaker
6/4/4 A
6/4 A
4
6/4/4 A
6/4 A
4
6/4/4 A
6/4 A
4
6/4/4 A
6/4 A
4
6/4/4 A
6/4 A
Releases
Undervoltage Releases (r Releases)
Response Voltage:
Drop (Breaker Tripped) U
s
Pickup (Breaker May Be Switched on) U
s
35 70%
85 110%
35 70%
85 110%
35 70%
85 110%
35 70%
85 110%
35 70%
85 110%
Power Consumption in Continuous Operation at:
50/60 Hz 12 Vac
50/60 Hz 24 Vac
50/60 Hz 48 60 Vac
50/60 Hz 110 127 Vac
50/60 Hz 208 240 Vac
50/60 Hz 380 500 Vac
50/60 Hz 525 600 Vac
12 Vdc
24 Vdc
48 60 Vdc
110 125 Vdc
220 250 Vdc
Maximum Opening Time
0.95 VA
0.72 VA
1.15 1.78 VA
0.96 1.25 VA
1.28 1.68 VA
2.2 3.9 VA
3.4 4.3 VA
0.88 W
0.70 W
1.12 1.76 W
0.94 1.21 W
1.45 1.86 W
50 ms
1.9 VA
3.9 VA
2.5 3.8 VA
1.8 2.4 VA
2.7 3.8 VA
3.4 5.8 VA
3.4 4.3 VA
1.6 W
3.1 W
2.0 3.1 W
1.6 2.2 W
3.1 4 W
50 ms
1.9 VA
3.9 VA
2.5 3.8 VA
1.8 2.4 VA
2.7 3.8 VA
3.4 5.8 VA
3.4 4.3 VA
1.6 W
3.1 W
2.0 3.1 W
1.6 2.2 W
3.1 4 W
50 ms
1.9 VA
2.4 VA
2.3 4.1 VA
3.4 4.2 VA
4.8 6.5 VA
6.8 12.0 VA
2.6 W
3.6 W
3.5 5.5 W
2.9 3.6 W
4.8 6.3 W
62 ms
2.9 VA
3.1 VA
3.4 6.0 VA
3.3 3.8 VA
4.2 7.2 VA
3.8 10.0 VA
3.4 W
4.3 W
4.8 7.2 W
3.3 3.8 W
6.6 7.5 W
62 ms
Shunt Trips
Shunt Trips (f Releases)
Response Voltage:
Pickup (Breaker Tripped) U
s
70 110% 70 110% 70 110% 70 110% 70 110%
Power Consumption in (Short Time) at:
50/60 Hz 24 Vac
50/60 Hz 48 60 Vac
50/60 Hz 48 127 Vac
50/60 Hz 110 240 Vac
50/60 Hz 380 440 Vac
50/60 Hz 380 600 Vac
50/60 Hz 480 600 Vac
12 24 Vdc
48 60 Vdc
110 125 Vdc
220 250 Vdc
10 41 VA
139 210 VA
83 360 VA
418 1080 VA
29 120 W
475 720 W
99 121 W
87 405 VA
710 1105 VA
66 432 VA
127 188 VA
34 60 VA
164 631 W
830 1580 W
112 150 W
40 58 W
87 405 VA
710 1105 VA
66 432 VA
127 188 VA
34 60 VA
164 631 W
830 1580 W
112 150 W
40 58 W
98 475 VA
24 50 VA
67 432 VA
76 110 VA
19 42 VA
145 610 W
67 102 W
121 150 W
46 55 W
612 VA
403 666 VA
396 1896 VA
1596 2156 VA
230 384 VA
396 W
341 528 W
264 350 W
374 475 W
Maximum Load Duration Interrupts Automatically
Maximum Opening Time 50 ms 50 ms 50 ms 62 ms 62 ms
Moulded Case Switch (with High Magnetic Trip)
Unfused kAIC at 480 Vac (415 Vac)
Self-Protected, Will Trip Above:
65 (70)
1250 for GE125;
1600 for GE160
65 (70)
2500
65 (70)
4000/6300
65 (70)
12,500
65 (70)
20,000
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
9
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GL Vol. 1, Ref. No. [09]
dc Switching Duty
The GE- to GL-Frame circuit breakers
are also suitable for switching dc
currents.
The GN- and GR-Frame circuit break-
ers are not suitable for dc currents
due to the solid-state overcurrent
release system.
For switching dc currents, however,
the maximum permissible dc voltage
per conducting path has to be
considered.
For voltages higher than 250 volts,
the series connection of two or three
conducting paths is required.
As the current has to ow through
all conducting paths so as to maintain
the thermal tripping characteristics,
the following circuit arrangements are
recommended. With dc, the trip values
of the instantaneous short circuit
release (n release) are increased
by 30 to 40%.
Table 4. For 3- and 4-Pole Circuit Breakers
Proposed
Circuit
Maximum
Permissible
Vdc U
e
Remarks
250 Vdc Double-pole switching.
If there is no risk of an earth fault, or if any
earth fault which occurs is immediately elimi-
nated (earth fault monitoring), the maximum
permissible dc voltage can be 600 volts.
440 Vdc Double-pole switching (earth system).
The earthed pole must always be assigned to
the individual conducting path, so that two
paths are always in series in the event of an
earth fault.
600 Vdc Single-pole switching (earthed system).
Three conducting paths in series. The earthed
pole must be assigned to the nonswitched
conducting path.
750 Vdc Single-pole switching (earthed system).
Four conducting paths in series. The earthed
pole must be assigned to the nonswitched
conducting path.
NSI-5178a
M
NSI-5179a
M
NSI-5180
M
NSI-5181
M
September 2005
10
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GJ through GR Vol. 1, Ref. No. [010]
Multi-Function Electronic
Trip Units for All Applications
Digitrip RMS Trip Units
True rms Sensing
Digitrip RMS Trip Units utilize our
patented microprocessor-based intelli-
gence to provide true rms sensing,
permitting increased accuracy and
reliable system protection. True rms
sensing is not susceptible to nuisance
tripping when waveforms containing
high harmonic currents are present.
Digitrip RMS 310
Digitrip RMS 310 Electronic Trip Units
are available with Cutler-Hammer
Circuit Breakers J-, L-, N- and R-
Frames 20 through 2500 amperes.
Digitrip RMS 310 Trip Units are avail-
able in four styles with either xed
or adjustable rating plugs which
establishes the continuous ampere
rating of the breaker.
Note: GJ- and GL-Frames have selectable
long time delay (t
LD
) and pickup settings
(I
r
). A rating plug is not required.
Rating Plugs
If rating plugs are needed, they
are marked for 50/60 Hz applications.
Both xed and adjustable rating
plugs are available, providing further
exibility when applied to selectively
coordinated systems.
Note: Digitrip RMS rating plugs are
not interchangeable with Seltronic
rating plugs.
Curve Shaping
When selectively coordinated systems
are called for, Digitrip RMS 310 will
provide a cost-effective solution for a
variety of applications.
The standard Digitrip RMS 310
includes an adjustable short time
pickup setting encompassing an I
2
t
ramp function which provides the
basic LS curve shaping function.
GJ- and GL-Frames have an
adjustable long time delay.
Note: GJ- and GL-Frames have selectable
long time delay (t
LD
) and pickup settings
(I
r
). A rating plug is not required.
The optional Digitrip RMS 310
provides additional at response
short time delay adjustments on
an instantaneous setting to provide
LSI curve shaping capability.
Digitrip RMS 310 Trip Units are
available with ground fault pickup
and at response ground fault delay
which provides the trip unit with full
function LSG and LSIG curve shaping
exibility.
Note: Contact factory for availability of
ground fault for GL-Frame trip unit.
Digitrip RMS 310 Trip Units can effec-
tively coordinate with both sophisti-
cated upstream power breakers as
well as downstream thermal magnetic
breakersmaking Digitrip RMS 310
Trip Units the cost-effective reliable
choice for selectively coordinated
systems.
Thermal Memory
All Digitrip RMS Trip Units incorporate
a long delay. Thermal memory prevents
the system from cumulative overheating
due to repeated overcurrent events that
may occur in quick succession.
Field Testing
A eld test kit is available for Digitrip
RMS 310 trip units.
Digitrip RMS 610 and 910
Digitrip RMS 610 and 910 Trip Units
are available with Cutler-Hammer
R-Frame Circuit Breakers 800 through
2500 amperes. Digitrip 610 and 910
Trip Units provide unparalleled
system protection with the added
convenience of a local display.
Curve Shaping
Digitrip RMS 610 and 910 Trip
Units are available with up to nine
curve shaping choices achieved by
adjusting up to seven switches on the
front of the unit for optimum system
coordination. Maximum curve shaping
exibility is provided by dependent
long and short delay adjustments that
are long delay pickup (I
r
) based,
depicted on the front of the unit by the
blue portion of the time-current curve.
Additional coordination capability
can be provided by utilizing the short
delay and ground fault zone selective
interlocking features available on
these trip units.
RMS 610 RMS 910
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
11
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GR Vol. 1, Ref. No. [011]
System Diagnostics
Digitrip RMS 610 and 910 models of
trip units provide long delay, short
delay, instantaneous, and ground fault
cause of trip LEDs on the front of the
unit. Their display shows a magnitude
of trip information, as well as remote
signal contacts, for improved system
alarming.
System Monitoring
Digitrip 610 and 910 Trip Units
have the capability to monitor
phase currents, as well as neutral or
ground currents. This information is
displayed on a large digital display
mounted on the unit.
Digitrip RMS 910 Trip Units can
also provide the user with power
and energy monitoring capability.
Peak power demand, present power
demand, and total energy, as well as
forward and reverse energy can be
monitored with this unit.
Digitrip RMS 910 Trip Units have the
additional capability of monitoring
line-to-line voltage, as well as system
power factor. Both parameters are dis-
played in the digital display window
and are supported by LEDs to indicate
which parameter is being displayed.
Harmonics Monitoring
Digitrip RMS 910 Trip Units are capa-
ble of displaying values of current
harmonics in the digital display win-
dow. Percentage of harmonic content
can be monitored for each phase,
up to the 27th harmonic. Additionally,
a total harmonic distortion value can
be calculated and displayed.
Communications
Digitrip RMS 910 units have built-in
communications options to allow all
protection, monitoring, and control
information to be transmitted back to a
central location via the Cutler-Hammer
PowerNet system.
Field Testing
Integral eld testing capability is
provided on all 610 and 910 Trip Units.
No additional test set is needed to per-
form both trip and no trip eld testing.
September 2005
12
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GJ through GR Vol. 1, Ref. No. [012]
Digitrip RMS Electronic Trip Unit Selection Guide
Table 5. Digitrip RMS Electronic Trip Unit Selection Guide
Yes Yes No No
Long Delay Setting 0.5 1.0 (l
n
)
0.5 1.0 (l
n
)
0.5 1.0 x (l
n
) 0.5 1.0 x (l
n
)
Long Delay Time I
2
t at 6x 10 Seconds
10 Seconds
2 24 Seconds 2 24 Seconds
Long Delay Thermal Memory Yes Yes Yes Yes
High Load Alarm No No 0.85 x I
r
0.85 x I
r
Short Delay Short Delay Setting 200 800% x (l
n
)
200 800% x (l
n
)
Yes
Var/Frame
25 100% x (l
n
)
25 100% x (l
n
)
I 500 ms
Includes Frame, Trip Unit, End Caps and Metric Mounting Hardware
Replace sufx M or G with W for no line and load terminals. Replace sufx M with G for standard cable terminals included.
16, 32, 63, 160 amperes are not NEMA rated. Maximum NEMA rating for GE is 125 amperes. Adjustable thermal trip units are typically used in IEC
markets and are not NEMA rated.
Maximum
Continuous
Ampere
Rating
at 40C
4-Pole
Fixed Thermal
Fixed Magnetic
Fixed Thermal
Fixed Magnetic
Fixed Thermal
Fixed Magnetic
Adjustable Thermal
Fixed Magnetic
Thermal
Range
Fixed Thermal
Fixed Magnetic
Adjustable Thermal
Fixed Magnetic
Thermal
Range
IC Rating: 25 kAIC at 240 Vac IC Rating: 18 kAIC at 415 and 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
160
GEB1015FFG
GEB1016FFG
GEB1020FFG
GEB1025FFG
GEB1030FFG
GEB1032FFG
GEB1035FFG
GEB1040FFG
GEB1045FFG
GEB1050FFG
GEB1060FFG
GEB1063FFG
GEB1070FFG
GEB1080FFG
GEB1090FFG
GEB1100FFG
GEB1125FFG
GEB2015FFG
GEB2016FFG
GEB2020FFG
GEB2025FFG
GEB2030FFG
GEB2032FFG
GEB2035FFG
GEB2040FFG
GEB2045FFG
GEB2050FFG
GEB2060FFG
GEB2063FFG
GEB2070FFG
GEB2080FFG
GEB2090FFG
GEB2100FFG
GEB2125FFG
GEB3015FFM
GEB3016FFM
GEB3020FFM
GEB3025FFM
GEB3030FFM
GEB3032FFM
GEB3035FFM
GEB3040FFM
GEB3045FFM
GEB3050FFM
GEB3060FFM
GEB3063FFM
GEB3070FFM
GEB3080FFM
GEB3090FFM
GEB3100FFM
GEB3125FFM
GEB3160FFM
GEB3020AFM
GEB3025AFM
GEB3032AFM
GEB3040AFM
GEB3050AFM
GEB3063AFM
GEB3080AFM
GEB3100AFM
GEB3125AFM
GEB3160AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
125 160
GEB7015FFM
GEB7016FFM
GEB7020FFM
GEB7025FFM
GEB7030FFM
GEB7032FFM
GEB7035FFM
GEB7040FFM
GEB7045FFM
GEB7050FFM
GEB7060FFM
GEB7063FFM
GEB7070FFM
GEB7080FFM
GEB7090FFM
GEB7100FFM
GEB7125FFM
GEB7160FFM
GEB7020AFM
GEB7025AFM
GEB7032AFM
GEB7040AFM
GEB7050AFM
GEB7063AFM
GEB7080AFM
GEB7100AFM
GEB7125AFM
GEB7160AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
125 160
IC Rating: 35 kAIC at 240 Vac IC Rating: 25 kAIC at 415 and 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
160
GEE2015FFG
GEE2016FFG
GEE2020FFG
GEE2025FFG
GEE2030FFG
GEE2032FFG
GEE2035FFG
GEE2040FFG
GEE2045FFG
GEE2050FFG
GEE2060FFG
GEE2063FFG
GEE2070FFG
GEE2080FFG
GEE2090FFG
GEE2100FFG
GEE2125FFG
GEE3015FFM
GEE3016FFM
GEE3020FFM
GEE3025FFM
GEE3030FFM
GEE3032FFM
GEE3035FFM
GEE3040FFM
GEE3045FFM
GEE3050FFM
GEE3060FFM
GEE3063FFM
GEE3070FFM
GEE3080FFM
GEE3090FFM
GEE3100FFM
GEE3125FFM
GEE3160FFM
GEE3020AFM
GEE3025AFM
GEE3032AFM
GEE3040AFM
GEE3050AFM
GEE3063AFM
GEE3080AFM
GEE3100AFM
GEE3125AFM
GEE3160AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
125 160
GEE7015FFM
GEE7016FFM
GEE7020FFM
GEE7025FFM
GEE7030FFM
GEE7032FFM
GEE7035FFM
GEE7040FFM
GEE7045FFM
GEE7050FFM
GEE7060FFM
GEE7063FFM
GEE7070FFM
GEE7080FFM
GEE7090FFM
GEE7100FFM
GEE7125FFM
GEE7160FFM
GEE7020AFM
GEE7025AFM
GEE7032AFM
GEE7040AFM
GEE7050AFM
GEE7063AFM
GEE7080AFM
GEE7100AFM
GEE7125AFM
GEE7160AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
125 160
Table 6. UL 489/IEC 60947-2 Interrupting Capacity Ratings
120 220 240 277 347 380 415 480 600Y/347 125 250
I
cu
I
cs
I
cu
I
cs
I
cu
I
cs
I
cu
I
cs
I
cu
I
cs
GEB 1
2, 3, 4
35
25
25
25
25
18
18
18
18
10
10
10
10
GEE 2, 3, 4 35 35 25 25 25 18 10 10
GES 1
2, 3, 4
100
85
85
43
43
35
22
40
30
35
22
22
35
35
35
35
GEH 1
2, 3, 4
200
100
100
50
50
65
25
70
35
65
25
25
42
42
42
42
GE Frame
September 2005
14
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GE, 160 Amperes (125 Amperes NEMA) Vol. 1, Ref. No. [014]
Table 7. Complete Circuit Breaker
Includes Frame, Trip Unit, End Caps and Metric Mounting Hardware (Continued)
Replace sufx M or G with W for no line and load terminals. Replace sufx M with G for standard cable terminals included.
16, 32, 63, 160 amperes are not NEMA rated. Maximum NEMA rating for GE is 125 amperes. Adjustable thermal trip units are typically used in IEC
markets and are not NEMA rated.
Table 8. Moulded Case Switches
4-Pole
Fixed Thermal
Fixed Magnetic
Fixed Thermal
Fixed Magnetic
Fixed Thermal
Fixed Magnetic
Adjustable Thermal
Fixed Magnetic
Thermal
Range
Fixed Thermal
Fixed Magnetic
Adjustable Thermal
Fixed Magnetic
Thermal
Range
IC Rating: 85 kAIC at 240 Vac IC Rating: 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
GES1015FFG
GES1016FFG
GES1020FFG
GES1025FFG
GES1030FFG
GES1032FFG
GES1035FFG
GES1040FFG
GES1045FFG
GES1050FFG
GES1060FFG
GES1063FFG
GES1070FFG
GES1080FFG
GES1090FFG
GES1100FFG
GES1125FFG
GES2015FFG
GES2016FFG
GES2020FFG
GES2025FFG
GES2030FFG
GES2032FFG
GES2035FFG
GES2040FFG
GES2045FFG
GES2050FFG
GES2060FFG
GES2063FFG
GES2070FFG
GES2080FFG
GES2090FFG
GES2100FFG
GES2125FFG
GES3015FFM
GES3016FFM
GES3020FFM
GES3025FFM
GES3030FFG
GES3032FFM
GES3035FFM
GES3040FFM
GES3045FFM
GES3050FFM
GES3060FFM
GES3063FFM
GES3070FFM
GES3080FFM
GES3090FFM
GES3100FFM
GES3125FFM
GES3020AFM
GES3025AFM
GES3032AFM
GES3040AFM
GES3050AFM
GES3063AFM
GES3080AFM
GES3100AFM
GES3125AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
GES7015FFM
GES7016FFM
GES7020FFM
GES7025FFM
GES7030FFM
GES7032FFM
GES7035FFM
GES7040FFM
GES7045FFM
GES7050FFM
GES7060FFM
GES7063FFM
GES7070FFM
GES7080FFM
GES7090FFM
GES7100FFM
GES7125FFM
GES7020AFM
GES7025AFM
GES7032AFM
GES7040AFM
GES7050AFM
GES7063AFM
GES7080AFM
GES7100AFM
GES7125AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
IC Rating: 100 kAIC at 240 Vac IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
GEH1015FFG
GEH1016FFG
GEH1020FFG
GEH1025FFG
GEH1030FFG
GEH1032FFG
GEH1035FFG
GEH1040FFG
GEH1045FFG
GEH1050FFG
GEH1060FFG
GEH1063FFG
GEH1070FFG
GEH1080FFG
GEH1090FFG
GEH1100FFG
GEH1125FFG
GEH2015FFG
GEH2016FFG
GEH2020FFG
GEH2025FFG
GEH2030FFG
GEH2032FFG
GEH2035FFG
GEH2040FFG
GEH2045FFG
GEH2050FFG
GEH2060FFG
GEH2063FFG
GEH2070FFG
GEH2080FFG
GEH2090FFG
GEH2100FFG
GEH2125FFG
GEH3015FFM
GEH3016FFM
GEH3020FFM
GEH3025FFM
GEH3030FFM
GEH3032FFM
GEH3035FFM
GEH3040FFM
GEH3045FFM
GEH3050FFM
GEH3060FFM
GEH3063FFM
GEH3070FFM
GEH3080FFM
GEH3090FFM
GEH3100FFM
GEH3125FFM
GEH3020AFM
GEH3025AFM
GEH3032AFM
GEH3040AFM
GEH3050AFM
GEH3063AFM
GEH3080AFM
GEH3100AFM
GEH3125AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
GEH7015FFM
GEH7016FFM
GEH7020FFM
GEH7025FFM
GEH7030FFM
GEH7032FFM
GEH7035FFM
GEH7040FFM
GEH7045FFM
GEH7050FFM
GEH7060FFM
GEH7063FFM
GEH7070FFM
GEH7080FFM
GEH7090FFM
GEH7100FFM
GEH7125FFM
GEH7020AFM
GEH7025AFM
GEH7032AFM
GEH7040AFM
GEH7050AFM
GEH7063AFM
GEH7080AFM
GEH7100AFM
GEH7125AFM
16 20
20 25
25 32
32 40
40 50
50 63
63 80
80 100
100 125
Ampere
Rating
Number
of Poles
Catalogue
Number
125
160
3
3
GEK3125KSM
GEK3160KSM
PG01200003E For more information visit: www.EatonElectrical.com
15
Series G Moulded Case Circuit Breakers
September 2005
15 2500 Amperes for IEC & NEMA Applications
Frame Size GE, 160 Amperes (125 Amperes NEMA) Vol. 1, Ref. No. [015]
Line and Load Terminals
GE-Frame circuit breakers and Moulded case switches have 3T125EF line and load
terminals as standard equipment.
Table 9. Line and Load Terminals
125
125
Aluminum
Aluminum
Cu/Al
Cu/Al
2.5-50
16-95
#14-1/0
#6-3/0
3TA125EF
3TA150EF
160
160
Aluminum
Aluminum
Cu/Al
Cu/Al
35-120
35-120
#3-250
#3-250
3TA160EFK
4TA160EFK
3T125EF
3TA125EF 3TA150EF
3TA160EFK
End Cap Kits
EF3RTWK, 3-Pole Metric (for 3-pole line or load)
EF4RTWK, 4-Pole Metric (for 4-pole line or load)
EF3RTDK, 3-Pole Imperial (for 3-pole line or load)
EF4RTDK, 4-Pole Imperial (for 4-pole line or load)
Control Wire Terminal Kit
For use with steel or stainless
steel terminals only.
Note: Standard line and load terminals
included with GE-Frame MCCBs.
Figure 4. Control Wire Terminal Kit
Table 10. Control Wire Terminal Kit
Interphase Barriers
The interphase barrier is available
for extended insulation between
circuit breaker poles. Specify quantity
when ordering.
Table 11. Interphase Barriers
Base Mounting Hardware
Metric base mounting hardware is
included with a circuit breaker or
Moulded case switch. A DIN rail
adapter is available.
Note: English mounting hardware kit can be
supplied: Catalogue Number BMHE.
Table 12. Base Mounting Hardware
Description Catalogue Number
Package of 12
(Priced Individually)
GCWTK
Description Catalogue Number
Package of 2 EIPBK
DIN Rail Adapter Catalogue Number
3- or 4-Pole EF34DIN
September 2005
16
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GE, 160 Amperes (125 Amperes NEMA) Vol. 1, Ref. No. [016]
Multiwire Connectors
Field-installed multiwire connectors
for the load side (OFF) end terminals.
They are used to distribute the load
from the circuit breaker to multiple
devices without the use of separate
distribution terminal blocks.
Multiwire lug kits include mounting
hardware, insulators and tin-plated
aluminum connectors to replace three
mechanical load lugs. UL listed for
copper only as used on the load side
(OFF) end.
Table 13. GE-Frame Multiwire Connectors
Ordering Information (Package of 3)
Figure 5. Multiwire Connectors
Terminal Shields
The terminal shield is available
for line terminal areas in 2-, 3- and
4-pole circuit breakers. The standard
style number by pole for each terminal
shield is for a package of 2 and is
priced per each package.
Table 14. Terminal Shields
Terminal End Covers (Gas Barrier)
The terminal end cover is available
for 3-pole circuit breakers only. Two
conductor opening sizes are available.
Specify quantity (one per circuit
breaker) when ordering.
Table 15. Terminal End Covers (Gas Barrier)
Maximum
Amperes
Wires
per
Terminal
Wire Size
Range
AWG Cu
Kit
Catalogue
Number
125
125
3
6
14 2
14 6
3TA100E3K
3TA100E6K
Number
of Poles
Standard
Package of 2
IP30
Protection
1P (Load end)
1P (Line end)
2
3
4
EFTS1KA
EFTS1KB
EFTS2K
EFTS3K
EFTS4K
Conductor Opening
Diameter mm (Inches)
Catalogue
Number
6.4 (0.25)
10.4 (0.41)
EEC3K
EEC4K
Terminal Extensions
Table 16. Terminal Extensions
Terminal Spreaders
Table 17. Terminal Spreaders
Figure 6. Terminal Spreaders
Number of Poles Catalogue Number
3
4
EFTES3
EFTES4
Number of Poles Catalogue Number
3
4
EFTEW3
EFTEW4
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
17
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GJ, 250 Amperes Vol. 1, Ref. No. [017]
GJ-Frame, 250 Amperes Selection Guide and Ordering Information
Table 19. Complete Circuit Breaker with Thermal-Magnetic Trip Unit
Includes Frame, Thermal-Magnetic Trip Units, End Caps and Metric Mounting Hardware
Replace sufx M or G with W for no line and load terminals. Replace sufx M with G for standard cable terminals included.
Adjustable thermal trip units are typically used in IEC markets and are not NEMA rated.
Neutral protection is indicated by the fourth character: 4 = 0%, 8 = adjustable 0 or 60% and 9 = 0 or 100%. 4-pole ground fault option does not have
neutral protection.
Maximum
Continuous
Ampere
Rating
at 40C
Magnetic
Range
2-Pole 3-Pole 4-Pole
Fixed
Thermal
Adjustable
Magnetic
Fixed
Thermal
Adjustable
Magnetic
Adjustable
Thermal
Adjustable
Magnetic
Thermal
Range
Fixed
Thermal
Adjustable
Magnetic
Adjustable
Thermal
Adjustable
Magnetic
Thermal
Range
IC Rating: 25 kAIC at 415 and 480 Vac
70
80
90
100
125
150
160
175
200
225
250
350 700
400 800
450 900
500 1000
625 1250
750 1500
800 1600
875 1750
1000 2000
1125 2250
1250 2500
GJE2070FAG
GJE2080FAG
GJE2100FAG
GJE2125FAG
GJE2150FAG
GJE2175FAG
GJE2200FAG
GJE2225FAG
GJE2250FAG
GJE3070FAM
GJE3080FAM
GJE3100FAM
GJE3125FAM
GJE3150FAM
GJE3175FAM
GJE3200FAM
GJE3225FAM
GJE3250FAM
GJE3080AAM
GJE3100AAM
GJE3125AAM
GJE3160AAM
GJE3200AAM
GJE3250AAM
64 80
80 100
100 125
128 160
160 200
200 250
GJE4070FAM
GJE4080FAM
GJE4100FAM
GJE4125FAM
GJE4150FAM
GJE4175FAM
GJE4200FAM
GJE4225FAM
GJE4250FAM
GJE4080AAM
GJE4100AAM
GJE4125AAM
GJE4160AAM
GJE4200AAM
GJE4250AAM
80 100
100 125
128 160
160 200
200 250
IC Rating: 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
70
80
90
100
125
150
160
175
200
225
250
350 700
400 800
450 900
500 1000
625 1250
750 1500
800 1600
875 750
1000 2000
1125 2250
1250 2500
GJS2070FAG
GJS2090FAG
GJS2100FAG
GJS2125FAG
GJS2150FAG
GJS2175FAG
GJS2200FAG
GJS2225FAG
GJS2250FAG
GJS3070FAM
GJS3090FAM
GJS3100FAM
GJS3125FAM
GJS3150FAM
GJS3175FAM
GJS3200FAM
GJS3225FAM
GJS3250FAM
GJS3080AAM
GJS3100AAM
GJS3125AAM
GJS3160AAM
GJS3200AAM
GJS3250AAM
64 80
64 80
80 100
100 125
128 160
160 200
200 250
GJS4070FAM
GJS4090FAM
GJS4100FAM
GJS4125FAM
GJS4150FAM
GJS4175FAM
GJS4200FAM
GJS4225FAM
GJS4250FAM
GJS4080AAM
GJS4100AAM
GJS4125AAM
GJS4160AAM
GJS4200AAM
GJS4250AAM
80 100
100 125
128 160
160 200
200 250
IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
70
80
90
100
125
150
160
175
200
225
250
350 700
400 800
450 900
500 1000
625 1250
750 1500
800 1600
875 1750
1000 2000
1125 2250
1250 2500
GJH2070FAG
GJH2090FAG
GJH2100FAG
GJH2125FAG
GJH2150FAG
GJH2175FAG
GJH2200FAG
GJH2225FAG
GJH2250FAG
GJH3070FAM
GJH3090FAM
GJH3100FAM
GJH3125FAM
GJH3150FAM
GJH3175FAM
GJH3200FAM
GJH3225FAM
GJH3250FAM
GJH3080AAM
GJH3100AAM
GJH3125AAM
GJH3160AAM
GJH3200AAM
GJH3250AAM
64 80
64 80
80 100
100 125
128 160
160 200
200 250
GJH4070FAM
GJH4090FAM
GJH4100FAM
GJH4125FAM
GJH4150FAM
GJH4160FAM
GJH4175FAM
GJH4200FAM
GJH4225FAM
GJH4250FAM
GJH4080AAM
GJH4100AAM
GJH4125AAM
GJH4160AAM
GJH4200AAM
GJH4250AAM
80 100
100 125
128 160
160 200
200 250
Table 18. UL 489/IEC 60947-2 Interrupting Capacity Ratings
I
cu
I
cs
I
cu
I
cs
I
cu
I
cs
I
cu
I
cs
GJE 2, 3, 4 65 65 25 25 25 18 12 6 10 10
GJS 2, 3, 4 85 85 40 40 35 18 12 6 22 22
GJH 2, 3, 4 100 100 70 70 65 25 14 7 22 22
GJC 2, 3, 4 200 150 100 75 100 50 20 10 42 42
GJ Frame
September 2005
18
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GJ, 250 Amperes Vol. 1, Ref. No. [018]
Table 19. Complete Circuit Breaker with Thermal-Magnetic Trip Unit
Includes Frame, Thermal-Magnetic Trip Units, End Caps and Metric Mounting (Continued)
Replace sufx M or G with W for no line and load terminals. Replace sufx M with G for standard cable terminals included.
Adjustable thermal trip units are typically used in IEC markets and are not NEMA rated.
Neutral protection is indicated by the fourth character: 4 = 0%, 8 = adjustable 0 or 60% and 9 = 0 or 100%.
Table 20. Complete GJ Breakers with Electronic Trip Unit
Replace sufx M or G with W for no line and load terminals. Replace sufx M with G for standard cable terminals included.
Neutral CT for LSG and LSIG applied to 4-wire applications must be ordered as a separate item.
Neutral protection 4 = 0%, 6 = 60%, 7 = 100% electronic trip unit neutral protection is not adjustable. 4-pole ground fault option does not have neutral
protection.
Maximum
Continuous
Ampere
Rating
at 40C
Magnetic
Range
2-Pole 3-Pole 4-Pole
Fixed
Thermal
Adjustable
Magnetic
Fixed
Thermal
Adjustable
Magnetic
Adjustable
Thermal
Adjustable
Magnetic
Thermal
Range
Fixed
Thermal
Adjustable
Magnetic
Adjustable
Thermal
Adjustable
Magnetic
Thermal
Range
IC Rating: Component Frame Only 25 kAIC at 415 and 480 Vac
250 GJE2250NN GJE3250NN GJE4250NN
IC Rating: Component Frame Only 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
250 GJS2250NN GJS3250NN GJS4250NN
IC Rating: Component Frame Only 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
250 GJH2250NN GJH3250NN GJH4250NN
Thermal-Magnetic Trip Unit
70
80
90
100
125
150
160
175
200
225
250
350 700
400 800
450 900
500 1000
625 1250
750 1500
800 1600
875 1750
1000 2000
1125 2250
1250 2500
JT2070FA
JT2090FA
JT2100FA
JT2125FA
JT2150FA
JT2160FA
JT2175FA
JT2200FA
JT2225FA
J2T250FA
JT3070FA
JT3090FA
JT3100FA
JT3125FA
JT3150FA
JT3175FA
JT3200FA
JT3225FA
JT3250FA
JT3080AA
JT3100AA
JT3125AA
JT3160AA
JT3200AA
JT3250AA
64 100
80 100
100 125
128 160
160 200
200 250
JT4070FA
JT4090FA
JT4100FA
JT4125FA
JT4150FA
JT4175FA
JT4200FA
JT4225FA
JT4250FA
JT4080AA
JT4100AA
JT4125AA
JT4160AA
JT4200AA
JT4250AA
80 100
100 125
128 160
160 200
200 250
Ampere Rating LS LSI LSG
LSIG
Neutral CT
Neutral protection 4 = 0%, 6 = 60%, 7 = 100% electronic trip unit neutral protection is not
adjustable.
Note: Long time pickup no rating plug.
250 Ampere Settings 250, 225, 200, 175, 160, 150, 125, 100.
160 Ampere Settings 160, 150, 125, 110, 100, 90, 80, 63.
100 Ampere Settings 100, 90, 80, 70, 63, 50, 45, 40.
50 Ampere Settings 50, 45, 40, 32, 30, 25, 20.
Note: Adjustable long time delay 2 24 seconds at 6 x I
r
.
Adjustable short time delay Inst., 120, 300 ms.
Note: Plug-in test kit Catalogue Numbers MTST120V (120 Vac) or MTST230V (230 Vac).
Digitrip 310+ Test Kit
Digitrip 310+ Test Kit Shown with GJ MCCB
GJ Digitrip 310+ Electronic Trip Unit
Ampere
Rating
LS LSI LSG LSIG Neutral CT
50
100
160
250
JT405033
JT410033
JT416033
JT425033
JT405032
JT410032
JT416032
JT425032
JT405035
JT410035
JT416035
JT425035
JT405036
JT410036
JT416036
JT425036
JGFCT050
JGFCT100
JGFCT160
JGFCT250
Table 22. Moulded Case Switches
(Includes Line and Load Collars)
September 2005
20
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GJ, 250 Amperes Vol. 1, Ref. No. [020]
Line and Load Terminals
GJ-Frame circuit breakers include Cu/Al terminals T250FJ as standard.
When optional copper only terminals are required, order by catalogue number.
Table 23. Line and Load Terminals
TA250FJ
Number
of Poles
Catalogue Number
Metric Imperial
3
4
FJ3RTWK
FJ4RTWK
FJ3RTDK
FJ4RTDK
Description Catalogue Number
Package of 14
(Priced Individually)
FJCWTK
Number of Poles Catalogue Number
3
4
FJTES3
FJTES4
Number of Poles Catalogue Number
3
4
FJTEW3
FJTEW4
Multiwire Connectors
Field-installed multiwire connectors
for the load side (OFF) end terminals.
They are used to distribute the load
from the circuit breaker to multiple
devices without the use of separate
distribution terminal blocks.
Multiwire lug kits include mounting
hardware, insulators and tin-plated
aluminum connectors to replace three
mechanical load lugs. UL listed for
copper only as used on the load side
(OFF) end.
Table 28. GJ-Frame Multiwire Connectors
Ordering Information (Package of 3)
Figure 10. GJ-Frame Multiwire Connectors
Base Mounting Hardware
Base mounting hardware is included
with a circuit breaker or Moulded
case switch.
Table 29. Terminal Shields IP30
Table 30. Interphase Barriers
Maximum
Amperes
Wires
per
Terminal
Wire Size
Range
AWG Cu
Kit
Catalogue
Number
250
250
3
6
14 2
14 6
3TA250J3
3TA250J6
Location Number
of Poles
Catalogue Number
Package of 1
Line or Load 2, 3
4
FJTS3K
FJTS4K
Package of 2
Number of Poles Catalogue Number
3
4
FJIPBK
FJIPBK4
PG01200003E For more information visit: www.EatonElectrical.com
21
Series G Moulded Case Circuit Breakers
September 2005
15 2500 Amperes for IEC & NEMA Applications
Frame Size GL, 630 Amperes (600 Amperes NEMA) Vol. 1, Ref. No. [021]
GL-Frame, 630 Amperes
Table 33. Thermal Magnetic Trip Unit
Neutral protection is indicated by the third character: 4 = 0%, 7 = 100%, 8 = adjustable 0 60% and
9 = 0 100%. 4-pole ground fault option does not have neutral protection.
Adjustable thermal, adjustable magnetic trip units are typically used in IEC markets and are
not NEMA rated.
Table 32. Complete Breaker (Includes Frame, Trip Unit, End Caps and Mounting Hardware)
Ampere
Rating
3-Pole
4-Pole (0%)
3-Pole
4-Pole (0%)
Fixed Thermal
Adj. Magnetic
Adj. Thermal
Adj. Magnetic
Fixed Thermal
Adj. Magnetic
Adj. Thermal
Adj. Magnetic
Fixed Thermal
Adj. Magnetic
Adj. Thermal
Adj. Magnetic
Fixed Thermal
Adj. Magnetic
Adj. Thermal
Adj. Magnetic
IC Rating: 35 kAIC at 415 and 480 Vac IC Rating: 50 kAIC at 415 and 480 Vac
250
300
320
350
GLE3250FAM
GLE3300FAM
GLE3350FAM
GLE3250AAM
GLE3320AAM
GLE4250FAM
GLE4300FAM
GLE4350FAM
GLE4250AAM
GLE4320AAM
GLS3250FAM
GLS3300FAM
GLS3350FAM
GLS3250AAM
GLS3320AAM
GLS4250FAM
GLS4350FAM
GLS4350FAM
GLS4250AAM
GLS4320AAM
400
500
600
630
GLE3400FAM
GLE3500FAM
GLE3600FAM
GLE3400AAM
GLE3500AAM
GLE3630AAM
GLE4400FAM
GLE4500FAM
GLE4600FAM
GLE4400AAM
GLE4500AAM
GLE4630AAM
GLS3400FAM
GLS3500FAM
GLS3600FAM
GLS3400AAM
GLS3500AAM
GLS3630AAM
GLS4400FAM
GLS4500FAM
GLS4600FAM
GLS4400AAM
GLS4500AAM
GLS4630AAM
IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac IC Rating: 100 kAIC at 415 and 480 Vac
250
300
320
350
GLH3250FAM
GLH3300FAM
GLH3350FAM
GLH3250AAM
GLH3320AAM
GLH4250FAM
GLH4300FAM
GLH4350FAM
GLH4250AAM
GLH4320AAM
GLC3250FAM
GLC3300FAM
GLC3350FAM
GLC3250AAM
GLC3320AAM
GLC4250FAM
GLC4300FAM
GLC4350FAM
GLC4250AAM
GLC4320AAM
400
500
600
630
GLH3400FAM
GLH3500FAM
GLH3600FAM
GLH3400AAM
GLH3500AAM
GLH3630AAM
GLH4400FAM
GLH4500FAM
GLH4600FAM
GLH4400AAM
GLH4500AAM
GLH4630AAM
GLC3400FAM
GLC3500FAM
GLC3600FAM
GLC3400AAM
GLC3500AAM
GLC3630AAM
GLC4400FAM
GLC4500FAM
GLC4600FAM
GLC4400AAM
GLC4500AAM
GLC4630AAM
Replace sufx M with W for no line and load terminals. Replace sufx M with G for standard cable terminals included.
Neutral protection is indicated by the fourth character: 4 = 0%, 7 = 100%, 8 = adjustable 0 60% and 9 = 0 100%. 4-pole ground fault option does not
have neutral protection.
630 amperes is not NEMA rated. 600 amperes is the maximum NEMA rating for the GL.
Adjustable thermal units are typically used in IEC markets and are not NEMA rated.
Ampere
Rating
3-Pole
4-Pole (0%)
Fixed Thermal/
Adj. Magnetic
Adj. Thermal/
Adj. Magnetic
Fixed Thermal/
Adj. Magnetic
Adj. Thermal/
Adj. Magnetic
250
300
320
350
LT3250FA
LT3300FA
LT3350FA
LT3250AA
LT3320AA
LT4250FA
LT4300FA
LT4350FA
LT4250AA
LT4320AA
400
500
600
630
LT3400FA
LT3500FA
LT3600FA
LT3400AA
LT3500AA
LT3630AA
LT4400FA
LT4500FA
LT4600FA
LT4400AA
LT4500AA
LT4630AA
Table 31. UL 489/IEC 60947-2 Interrupting Capacity Ratings
Circuit
Breaker
Type
Number
of Poles
Interrupting Capacity (kA Symmetrical Amperes)
Volts ac (50/60 Hz) Volts dc
220 240 Vac 380 415 Vac 480 Vac 600 Vac 690 Vac 250 V
I
cu
I
cs
I
cu
I
cs
I
cu
I
cs
I
cu
I
cs
GLE 3, 4 65 65 35 35 35 18 12 9 22 22
GLS 3, 4 85 85 50 50 50 25 20 10 22 22
GLH 3, 4 100 100 70 70 65 35 25 13 42 42
GLC 3, 4 200 150 100 75 100 50 35 18 42 42
GL Frame
Table 34. Moulded Case Switches
4
GLK3400KSM
GLK4400KSM
630
4
GLK3630KSM
GLK4630KSM
Ampere
Rating
IC Rating at
415/480 V
3-Pole
4-Pole
(0%)
630
630
630
630
35/35
50/50
70/65
100/100
GLE3630NN
GLS3630NN
GLH3630NN
GLC3630NN
GLE4630NN
GLS4630NN
GLH4630NN
GLC4630NN
September 2005
22
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GL, 630 Amperes (600 Amperes NEMA) Vol. 1, Ref. No. [022]
Table 36. Electronic Trip Units Digitrip 310+
630 amperes is not NEMA rated. 600 amperes is the maximum NEMA rating for the GL.
Neutral protection: 4= 0%, 6 = 60%, 7 = 100%. Electronic trip unit neutral protection is not
adjustable. 4-pole ground fault option does not have neutral protection.
Note: Long time pickup no rating plug needed.
630 Ampere Settings 630, 600, 500, 400, 350, 315, 300, 250 (315, 630 are IEC ratings only).
600 Ampere Settings 600, 500, 450, 400, 350, 315, 300, 250 (315 is IEC rating only).
400 Ampere Settings 400, 350, 315, 300, 250, 225, 200, 160 (315 is IEC rating only).
250 Ampere Settings 250, 225, 200, 175, 160, 150, 125, 100 (160 is IEC rating only).
Note: Adjustable long time delay 2 24 seconds at 6 x I
r
.
Adjustable short time delay Inst., 120, 300 ms.
Note: Plug-in test kit Catalogue Numbers MTST120V (120 Vac) and MTST230V (230 Vac).
Ampere
Rating
LS LSI LSG LSIG Neutral CT
for LSG & LSIG
3-Pole
250
400
600
630
LT325033
LT340033
LT360033
LT363033
LT325032
LT340032
LT360032
LT363032
LT325035
LT340035
LT360035
LT363035
LT325036
LT340036
LT360036
LT363036
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole
250
400
600
630
LT425033
LT440033
LT460033
LT463033
LT425032
LT440032
LT460032
LT463032
LT425035
LT440035
LT460035
LT463035
LT425036
LT440036
LT460036
LT463036
LGFCT250
LGFCT400
LGFCT600
LGFCT630
Digitrip 310+ Test Kit
Digitrip 310+ Test Kit Shown with GJ MCCB
GL Digitrip 310+ Electronic Trip Unit
PG01200003E For more information visit: www.EatonElectrical.com
23
Series G Moulded Case Circuit Breakers
September 2005
15 2500 Amperes for IEC & NEMA Applications
Frame Size GL, 630 Amperes (600 Amperes NEMA) Vol. 1, Ref. No. [023]
Table 37. IC Rating at 415/480 V Complete GL Breakers with Electronic Trip Unit
(Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware)
Replace sufx M with W for no line and load terminals. Replace sufx M with G for
standard cable terminals included.
630 amperes is not NEMA rated. 600 amperes is the maximum NEMA rating for the GL.
Neutral protection: 4= 0%, 6 = 60%, 7 = 100%. Electronic trip unit neutral protection is not
adjustable. 4-pole with ground fault option does not have neutral protection.
Ampere
Rating
LS LSI LSG LSIG Neutral CT
for LSG & LSIG
3-Pole
GLE325033M
GLE340033M
GLE360033M
GLE363033M
GLE325032M
GLE340032M
GLE360032M
GLE363032M
GLE325035M
GLE340035M
GLE360035M
GLE363035M
GLE325036M
GLE340036M
GLE360036M
GLE363036M
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole
GLE425033M
GLE440033M
GLE460033M
GLE463033M
GLE425032M
GLE440032M
GLE460032M
GLE463032M
GLE425035M
GLE440035M
GLE460035M
GLE463035M
GLE425036M
GLE440036M
GLE460036M
GLE463036M
LGFCT250
LGFCT400
LGFCT600
LGFCT630
3-Pole
GLS325033M
GLS340033M
GLS360033M
GLS363033M
GLS325032M
GLS340032M
GLS360032M
GLS363032M
GLS325035M
GLS340035M
GLS360035M
GLS363035M
GLS325036M
GLS340036M
GLS360036M
GLS363036M
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole
GLS425033M
GLS440033M
GLS460033M
GLS463033M
GLS425032M
GLS440032M
GLS460032M
GLS463032M
GLS425035M
GLS440035M
GLS460035M
GLS463035M
GLS425036M
GLS440036M
GLS460036M
GLS463036M
LGFCT250
LGFCT400
LGFCT600
LGFCT630
3-Pole
GLH325033M
GLH340033M
GLH360033M
GLH363033M
GLH325032M
GLH340032M
GLH360032M
GLH363032M
GLH325035M
GLH340035M
GLH360035M
GLH363035M
GLH325036M
GLH340036M
GLH360036M
GLH363036M
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole
GLH425033M
GLH440033M
GLH460033M
GLH463033M
GLH425032M
GLH440032M
GLH460032M
GLH463032M
GLH425035M
GLH440035M
GLH460035M
GLH463035M
GLH425036M
GLH440036M
GLH460036M
GLH463036M
LGFCT250
LGFCT400
LGFCT600
LGFCT630
September 2005
24
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GL, 630 Amperes (600 Amperes NEMA) Vol. 1, Ref. No. [024]
Line and Load Terminals
Table 38. Line and Load Terminals
4TA631LK
400
400
Copper
Copper
Cu
Cu
500 750 (1)
500 750 (1)
240 380 (1)
240 380 (1)
3
4
3T631LK
4T631LK
630
630
Aluminum
Aluminum
Cu/Al
Cu/Al
2 500 (2)
2 500 (2)
35 240 (2)
35 240 (2)
3
4
3TA632LK
4TA632LK
630
630
Copper
Copper
Cu
Cu
2 500 (2)
2 500 (2)
35 240 (2)
35 240 (2)
3
4
3T632LK
4T632LK
400
400
Aluminum
Copper
Cu/Al
Cu
2 500 (1)
2 500 (1)
35 240 (1)
35 240 (1)
1
1
TA350LK
T350LK
Description Catalogue
Number
3-Pole Terminal Cover
LTS3K
LTS4K
Number
of Poles
Catalogue
Number
3
4
L3RTWK
L4RTWK
Number
of Poles
Catalogue
Number
3
4
LGTEW3
LGTEW4
Number
of Poles
Catalogue
Number
3
4
LGTES3
LGTES4
Description Catalogue
Number
3 (Pack of 2)
4 (Pack of 3)
IPB3
IPB34
Warning
Label
TA350L or
T350L Terminal TA631L, T631L, T632L
or TA632L step-type terminal kits
listed above include LTS3K (3-pole)
or LTS4K (4-pole) terminal
cover and warning label (required
for proper application).
Terminal Cover
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
25
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GN, 1250/1600 Amperes 50 kA at 480 Vac or 415 Vac Vol. 1, Ref. No. [025]
GN-Frame
Table 44. UL 489/IEC 60947-2 Interrupting Capacity Ratings
85 85 50 50 50 25 20
10
H 2, 3, 4
100 100 70 50 65 35 25
13
C
2, 3, 4
85 85 50 50 50 25 20
10
H 2, 3, 4
100 100 70 50 65 35 25
13
GN Frame
1250 Amperes Selection Guide and Ordering Information
September 2005
26
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GN, 1250 Amperes 50 kA at 480 Vac or 415 Vac Vol. 1, Ref. No. [026]
Table 46. Type GNS Standard Interrupting Capacity U
e
Max. 690 Vac, 50 kA l
cu
at 480 Vac or 415 Vac
GN MCCBs are suitable for 40C or 50C applications. Order sufx V3 to eliminate standard 40C labeling.
Unprotected left pole neutral. Insert E for 100% neutral or EH for 60% neutral between W and P (e.g., GNS412T32EHP08).
4-pole with ground fault option does not have neutral protection.
For 2-pole applications, use outer poles of 3-pole moulded case switch.
Maximum
Continuous
Ampere
Rating
at 40C
Number
of Poles
Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit
without Rating Plugs Catalogue Number
Ampere
Rating
Must Add
Proper Rating
Plug Sufx
to Complete
Breaker
Separate
Rating Plugs
L Adj. Long Delay Pickup (By Adj. Rating Plug)
S Adj. Short Delay Pickup with Fixed Short Delay Time
(I
2
t Response) or Adj. Short Delay Time (Flat Response)
I Adj. Instantaneous Pickup by Setting Short Delay Time to Inst.
G Adj. Ground Fault Pickup with Adj. Ground Fault Delay (Flat Response)
LS LSI LSG LSIG
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 8 x I
n
2 8 x I
n
I 300 ms
2 8 x I
n
200 1200 A
I 500 ms
2 8 x I
n
I 300 ms
200 1200 A
I 500 ms
Fixed Adj. Fixed Adjustable
800 2-Pole GNS2800T33W GNS2800T32W GNS2800T35W GNS2800T36W 400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
3-Pole GNS3800T33W GNS3800T32W GNS3800T35W GNS3800T36W 400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
4-Pole
GNS4800T33W GNS4800T32W
400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
NEMA GN 1200 with 1200 A Trip Units is Also Available
1250 2-Pole GNS2125T33W GNS2125T32W GNS2125T35W GNS2125T36W 600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
3-Pole GNS3125T33W GNS3125T32W GNS3125T35W GNS3125T36W 600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
4-Pole
GNS4125T33W GNS4125T32W
600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
Ampere Rating Number of Poles U
e
Max. 690 Vac Catalogue Number
800 3-Pole
4-Pole
GNK3800KSW
GNK4800KSW
MCS Only without
Line and Load Terminals
1250 3-Pole
4-Pole
GNK312KSW
GNK412KSW
MCS Only without
Line and Load Terminals
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
27
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GN, 1250 Amperes 65 kA at 480 Vac, 70 kA at 415 Vac Vol. 1, Ref. No. [027]
Table 48. Type GNH High Interrupting Capacity U
e
Max. 690 Vac, 65 kA I
cu
at 480 Vac, 70 kA I
cu
at 415 Vac
GN MCCBs are suitable for 40C or 50C applications. Order sufx V3 to eliminate standard 40C labeling.
Unprotected left pole neutral. Insert E for 100% neutral or EH for 60% neutral between W and P (e.g., GNS412T32EHP08).
4-pole with ground fault option does not have neutral protection.
Number
of Poles
Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit
without Rating Plugs Catalogue Number
Ampere
Rating
Must Add
Proper Rating
Plug Sufx
to Complete
Breaker
Separate
Rating Plugs
L Adj. Long Delay Pickup (By Adj. Rating Plug)
S Adj. Short Delay Pickup with Fixed Short Delay Time
(I
2
t Response) or Adj. Short Delay Time (Flat Response)
I Adj. Instantaneous Pickup by Setting Short Delay Time to Inst.
G Adj. Ground Fault Pickup with Adj. Ground Fault Delay (Flat Response)
LS LSI LSG LSIG
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 8 x I
n
2 8 x I
n
I 300 ms
2 8 x I
n
200 1200 A
I 500 ms
2 8 x I
n
I 300 ms
200 1200 A
I 500 ms
Fixed Adj. Fixed Adjustable
800 2-Pole GNH2800T33W GNH2800T32W GNH2800T35W GNH2800T36W 400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
3-Pole GNH3800T33W GNH3800T32W GNH3800T35W GNH3800T36W 400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
4-Pole
GNH4800T33W GNH4800T32W
400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
NEMA GN 1200 with 1200 A Trip Units is Also Available
1250 2-Pole GNH2125T33W GNH2125T32W GNH2125T35W GNH2125T36W 600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
3-Pole GNH3125T33W GNH3125T32W GNH3125T35W GNH3125T36W 600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
4-Pole
GNH4125T33W GNH4125T32W
600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
September 2005
28
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GN, 1250 Amperes 100 kA at 480 Vac or 415 Vac Vol. 1, Ref. No. [028]
Table 49. Type GNC Very High Capacity U
e
Max. 690 Vac, 100 kA I
cu
at 480 Vac or 415 Vac
GN MCCBs are suitable for 40C or 50C applications. Order sufx V3 to eliminate standard 40C labeling.
Unprotected left pole neutral. Insert E for 100% neutral or EH for 60% neutral between W and P (e.g., GNS412T32EHP08).
4-pole with ground fault option does not have neutral protection.
Number
of Poles
Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit
without Rating Plugs Catalogue Number
Ampere
Rating
Must Add
Proper Rating
Plug Sufx
to Complete
Breaker
Separate
Rating Plugs
L Adj. Long Delay Pickup (By Adj. Rating Plug)
S Adj. Short Delay Pickup with Fixed Short Delay Time
(I
2
t Response) or Adj. Short Delay Time (Flat Response)
I Adj. Instantaneous Pickup by Setting Short Delay Time to Inst.
G Adj. Ground Fault Pickup with Adj. Ground Fault Delay (Flat Response)
LS LSI LSG LSIG
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 8 x I
n
2 8 x I
n
I 300 ms
2 8 x I
n
200 1200 A
I 500 ms
2 8 x I
n
I 300 ms
200 1200 A
I 500 ms
Fixed Adj. Fixed Adjustable
800 2-Pole GNC2800T33W GNC2800T32W GNC2800T35W GNC2800T36W 400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
3-Pole GNC3800T33W GNC3800T32W GNC3800T35W GNC3800T36W 400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
4-Pole
GNC4800T33W GNC4800T32W
400
450
500
550
P17
P16
P15
P14
400/500/
600/800
P18
8NES400T
8NES450T
8NES500T
8NES550T
400/500/
600/800
A8NES800T1
600
630
700
800
P13
P12
P11
P10
400/500/
630/800
P19
8NES600T
8NES630T
8NES700T
8NES800T
400/500/
630/800
A8NES800T2
NEMA GN 1200 with 1200 A Trip Units is Also Available
1250 2-Pole GNC2125T33W GNC2125T32W GNC2125T35W GNC2125T36W 600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
3-Pole GNC3125T33W GNC3125T32W GNC3125T35W GNC3125T36W 600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
4-Pole
GNC4125T33W GNC4125T32W
600
630
700
800
P07
P06
P05
P04
600/800/
1000/1200
P08
12NES600T
12NES630TW
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
1250
P20
P03
P02
P01
630/800/
1000/1250
P09
12NES900T
12NES1000T
12NES1200T
12NES1250TW
630/800/
1000/1250
A12NES1250T2
PG01200003E For more information visit: www.EatonElectrical.com
29
Series G Moulded Case Circuit Breakers
September 2005
15 2500 Amperes for IEC & NEMA Applications
Frame Size GN, 1600 Amperes 50 kA/70 kA at 415 Vac Vol. 1, Ref. No. [029]
Line and Load Terminals
N-Frame circuit breakers do not include terminals as standard. When copper or
Cu/Al terminals are required, order by catalogue number.
Table 51. Line and Load Terminals
Number
of Poles
Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit and Adjustable Rating Plugs Adjustable
Rating Plug
L Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S Adjustable Short Delay Pickup with Fixed Short Delay Time
(I
2
t Response) or Adjustable Short Delay Time (Flat Response)
I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response)
LS LSI LSG LSIG
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 8 x I
n
2 8 x I
n
I 300 ms
2 8 x I
n
200 1200 A
I 500 ms
2 8 x I
n
I 300 ms
200 1200 A
I 500 ms
1600
3-Pole
4-Pole
GNS316T33WP35
GNS416T33WP35
GNS316T32WP35
GNS416T32WP35
GNS316T35WP35
GN316T36WP35
800/1000/1250/1600
1600 3-Pole
4-Pole
GNH316T33WP35
GNH416T33WP35
GNH316T32WP35
GNH416T32WP35
GNH316T35WP35
GNHS316T36WP35
800/1000/1250/1600
GN MCCBs are suitable for 40C or 50C applications. Order sufx V3 to eliminate standard 40C labeling.
Unprotected left pole neutral. Insert 1 for 100% protected neutral or 6 for 60% protected neutral before WP sufx (e.g., GNS416T336WP35).
4-pole with ground fault option does not have neutral protection.
135 100 70 50 65 50 25
13
C
3, 4
18
GR Frame
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
31
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GR, 2500 Amperes 65 kA at 480 Vac, 70 kA at 415 Vac Digitrip 310 Trip Unit Vol. 1, Ref. No. [031]
Table 57. Type GRH with Digitrip 310 High Interrupting Capacity U
e
Max. 690 Vac, 70 kA I
cu
at 415 Vac
Ground fault equipped trip units available with remote indicating panel. Add R to catalogue number, e.g., GRH316T35RW.
Unprotected left pole neutral. Add P to catalogue number for 100% protected left pole neutral, add E for 60% protected, e.g.,
GRH416T33PW, GRH416T33EW.
Number
of Poles
Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit
without Rating Plugs Catalogue Number
Ampere
Rating
Must Add
Proper Rating
Plug Sufx
to Complete
Breaker
Separate
Rating Plugs
L Adj. Long Delay Pickup (By Adj. Rating Plug)
S Adj. Short Delay Pickup with Fixed Short Delay Time
(I
2
t Response) or Adj. Short Delay Time (Flat Response)
I Adj. Inst. Pickup by Setting Short Delay Time to Instantaneous
G Adj. Ground Fault Pickup with Adj. Ground Fault Delay (Flat Response)
LS LSI LSG
LSIG
2 8 x I
n
I 300 ms
2 8 x I
n
200 1200 A
I 500 ms
2 8 x I
n
I 300 ms
200 1200 A
I 500 ms
Fixed Adj. Fixed Adj.
1600
4-Pole
GRH416T33W GRH416T32W
800
1000
1200
1250
P07
P06
P05
P04
800/1000/
1200/1600
P08
16RES08T
16RES10T
16RES12T
16RES125T
800/1000/
1200/1600
A16RES16T1
1400
1500
1600
P03
P02
P01
800/1000/
1250/1600
P09
16RES14T
16RES15T
16RES16T
800/1000/
1250/1600
A16RES16T2
2000 GRH420T33W GRH420T32W
1000
1200
1250
P15
P14
P13
1000/1200/
1600/2000
P16
20RES10T
20RES12T
A20RES125T
1000/1200/
1600/2000
A20RES20T1
1400
1600
2000
P12
P11
P10
1000/1250/
1600/2000
P17
A20RES14T
A20RES16T
A20RES20T
1000/1250/
1600/2000
A20RES20T2
2500 GRH425T33W GRH425T32W
1200
1250
1600
P34
P35
P36
1200/1600/
2000/2500
P39
25RES12T
25RES125T
A25RES16T
1200/1600/
2000/2500
A25RES25T1
2000
2500
P37
P38
1250/1600/
2000/2500
P40
A25RES20T
A25RES25T
1250/1600/
2000/2500
A25RES25T2
September 2005
32
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GR, 2500 Amperes 100 kA at 480 Vac, 415 Vac Digitrip 310 Trip Unit Vol. 1, Ref. No. [032]
Table 58. Type GRC with Digitrip 310 Very High Interrupting Capacity U
e
Max. 690 Vac, 100 kA I
cu
at 415 Vac
Ground fault equipped trip units available with remote indicating panel. Add R to catalogue number, e.g., GRH316T35RW.
Unprotected left pole neutral. Add P to catalogue number for 100% protected left pole neutral, add E for 60% protected, e.g.,
GRH416T33PW, GRH416T33EW.
Note: GR MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required.
Table 59. Moulded Case Switches
Maximum
Continuous
Ampere
Rating
at 40C
Number
of Poles
Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit
without Rating Plugs Catalogue Number
Ampere
Rating
Must Add
Proper Rating
Plug Sufx
to Complete
Breaker
Separate
Rating Plugs
L Adj.Long Delay Pickup (By Adj. Rating Plug)
S Adj. Short Delay Pickup with Fixed Short Delay Time
(I
2
t Response) or Adj. Short Delay Time (Flat Response)
I Adj. Inst. Pickup by Setting Short Delay Time to Inst.
G Adj. Ground Fault Pickup with Adj. Ground Fault Delay (Flat Response)
LS LSI LSG
LSIG
2 8 x I
n
I 300 ms
2 8 x I
n
200 1200 A
I 500 ms
2 8 x I
n
I 300 ms
200 1200 A
I 500 ms
Fixed Adj. Fixed Adj.
1600
4-Pole
GRC416T33W GRC416T32W
800
1000
1200
1250
P07
P06
P05
P04
800/1000/
1200/1600
P08
16RES08T
16RES10T
16RES12T
16RES125T
800/1000/
1200/1600
A16RES16T1
1400
1500
1600
P03
P02
P01
800/1000/
1250/1600
P09
16RES14T
16RES15T
16RES16T
800/1000/
1250/1600
A16RES16T2
2000 GRC420T33W GRC420T32W
1000
1200
1250
P15
P14
P13
1000/1200/
1600/2000
P16
20RES10T
20RES12T
A20RES125T
1000/1200/
1600/2000
A20RES20T1
1400
1600
2000
P12
P11
P10
1000/1250/
1600/2000
P17
A20RES14T
A20RES16T
A20RES20T
1000/1250/
1600/2000
A20RES20T2
2500
GRC425T33W GRC425T32W
1200
1250
1600
P34
P35
P36
1200/1600/
2000/2500
P39
25RES12T
25RES125T
A25RES16T
1200/1600/
2000/2500
A25RES25T1
2000
2500
P37
P38
1250/1600/
2000/2500
P40
A25RES20T
A25RES25T
1250/1600/
2000/2500
A25RES25T2
Ampere Rating Number of Poles Catalogue Number
1600
2000
3-Pole GRK316WK
GRK320WK
1600
2000
4-Pole GRK416WK
GRK420WK
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
33
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GR, 1250 Amperes Digitrip 610 & 910 Trip Units Vol. 1, Ref. No. [033]
Table 60. Type GR with Digitrip 610 and 910
Digitrip RMS
Interchangeable
Rating Plug
(Order as Individual
Component)
L Adjustable Long Delay Pickup (I
r
) with Adjustable Long Delay Time
S Adjustable Short Delay Pickup with Adjustable Short Delay Time (I
2
t or Flat Response)
I Adjustable Instantaneous Pickup
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I
2
t or Flat Response)
LI LS LSI LIG LSG LSIG Fixed Rating Plug
Long Delay Pickup
Long Delay Time
Short Time Range
Short Time Delay
Instantaneous
Ground Fault Pickup
Ground Fault Delay
0.5 1.0 x I
n
2 24 Seconds
2 6 x I
r
2 6 x M1 & M2
0.5 I.0
n
2 24 Seconds
2 6 x I
r
100 500 ms
0.5 1.0 x I
n
2 24 Seconds
2 6 x I
r
100 500 ms
2 6 x M1 & M2
0.5 1.0 x I
n
2 24 Seconds
2 6 x I
r
2 6 x M1 & M2
0.25 1.0 x In
100 500 ms
0.5 1.0 x I
n
2 24 Sec.
2 6 x I
r
100 500 ms
0.25 1.0 x In
100 500 ms
0.5 1.0 x I
n
2 24 Seconds
2 6 x I
r
100 500 ms
2 6 x M1 & M2
0.25 1.0 x In
100 500 ms
Ampere
Rating
Catalogue
Number
Type GRH with Digitrip 610 High Interrupting Capacity U
e
Max. 690 Vac, 70 kA I
cu
at 415 Vac
1600 3-Pole GRH316T61WP44 GRH316T63WP44 GRH316T62WP44 GRH316T64WP44 GRH316T65WP44 GRH316T66WP44 800
1000
1200
1250
1600
RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A125
RP6R16A160
Includes 1600 A Rating Plug
2000 GRH320T61WP49 GRH320T63WP49 GRH320T62WP49 GRH320T64WP49 GRH320T65WP49 GRH320T66WP49 1000
1200
1250
1600
2000
RP6R20A100
RP6R20A120
RP6R20A125
RP6R20A160
RP6R20A200
Includes 2000 A Rating Plug
2500 GRH325T61WP53 GRH325T63WP53 GRH325T62WP53 GRH325T64WP53 GRH325T65WP53 GRH325T66WP53 1600
2000
2500
RP6R25A160
RP6R25A200
RP6R25A250
Includes 2500 A Rating Plug
Type GRC with Digitrip 610 Very High Interrupting Capacity U
e
Max. 690 Vac, 100 kA I
cu
at 415 Vac
1600 3-Pole GRC316T61WP44 GRC316T63WP44 GRC316T62WP44 GRC316T64WP44 GRC316T65WP44 GRC316T66WP44 800
1000
1200
1250
1600
RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A125
RP6R16A160
Includes 1600 A Rating Plug
2000 GRC320T61WP49 GRC320T63WP49 GRC320T62WP49 GRC320T64WP49 GRC320T65WP49 GRC320T66WP49 1000
1200
1250
1600
2000
RP6R20A100
RP6R20A120
RP6R20A125
RP6R20A160
RP6R20A200
Includes 2000 A Rating Plug
2500
Order one TA2000RD kit per 3-poles. Catalogue number includes bus connection, terminals and
hardware for either line side or load side of 3-pole breaker.
Note: GR MCCBs have metric threading on line and load conductors. Use RD MCCBs if
imperial threading is required.
Figure 13. GR Rear Connector Exploded View
Order one per pole (or two per pole if line and load terminals are required) single terminals
individually packed.
Note: GR MCCBs have metric threading on line and load conductors. Use RD MCCBs if
imperial threading is required.
Maximum
Breaker
Amperes
Terminal
Body
Material
Wire
Type
Hardware AWG/kcmil
Wire Range/
Number
of Conductors
Metric Wire
Range mm
2
Catalogue
Number
Wire Terminals
1600
1600
2000
Aluminum
Copper
Aluminum
Cu/Al
Cu
Cu/Al
Metric
Metric
Metric
500 1000 (4)
1 600 (4)
2 600 (6)
300 500
50 300
35 300
TA1600RDM
T1600RDM
TA2000RDM
Rear Connectors
2000
2000
2500
Copper
Copper
Copper
Metric
Metric
Metric
B2016RDM
B2016RDLM
B2500RDM
Conductor
(Viewed from Front
of Circuit Breaker)
Conductor
(Viewed from Rear
of Circuit Breaker and
Cut Away for Clarity)
Rear Connector (Cu)
B2016RD
B2016RDL (For 100% Application)
(For 1600 A and 2000 A Frames)
Securing
Hardware
Securing Hardware
Cu Only
Terminal
Catalogue
Number
T1600RD
(For 1600 A
Frame Only)
Al/Cu
Terminal
Catalogue
Number
TA1600RD
(For 1600 A
Frame Only)
OR
Figure 14. TA2000RD Wire Terminal
Note: Order one TA2000R0M kit per 3-poles.
Catalogue number includes bus connection,
terminals and hardware for either line side
or load side of 3-pole breaker.
Base Mounting Hardware
Supplied by customer.
Handle Extension
Included with breaker. Additional
handle extensions are available.
Table 62. Handle Extension
Description Catalogue
Number
Single Handle Extension HEX6
NEED ART
FROM PG. 29 OF
PG.29B.01A.T.U
(FEB, 2001)
Breaker Line/Load
Conductors
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
35
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Motor Circuit Protectors Vol. 1, Ref. No. [035]
Motor Circuit Protectors Selection Guide and Ordering Information
Table 63. GE-Frame 600Y/347 Vac Maximum, 250 Vdc Maximum
MCP Trip
Setting
MCP Catalogue
Number
3 A
B
C
D
E
F
.69 .91
1.1 1.3
1.6 1.7
2.0 2.2
2.3 2.5
2.6
9
15
21
27
30
33
HMCPE003A0C
7 A
B
C
D
E
F
1.5 2.0
2.6 3.1
3.7 3.9
4.8 5.2
5.3 5.7
5.8 6.1
21
35
49
63
70
77
HMCPE007C0C
15 A
B
C
D
E
F
3.4 4.5
5.7 6.8
8.0 9.1
10.4 11.4
11.5 12.6
12.7 13.0
45
75
105
135
150
165
HMCPE015E0C
30 A
B
C
D
E
F
3.9 9.1
11.5 13.7
16.1 18.3
20.7 22.9
23.0 25.2
25.3 26.1
90
150
210
270
300
330
HMCPE030H1C
50 A
B
C
D
E
F
11.5 15.2
19.2 22.9
26.9 30.6
34.6 38.3
38.4 42.1
42.2 43.5
150
250
350
450
500
550
HMCPE050K2C
70 A
B
C
D
E
F
16.1 30.6
26.9 32.2
37.6 42.9
48.4 53.7
53.8 59.1
59.2 60.9
210
350
490
630
700
770
HMCPE070M2C
100 A
B
C
D
E
F
23.0 30.6
38.4 46.0
53.8 61.4
69.2 76.8
76.9 84.5
84.6 87.0
300
500
700
900
1000
1100
HMCPE100R3C
100 A
B
C
D
E
F
38.4 46.0
57.6 65.2
76.9 84.5
500
750
1000
1250
1375
1500
HMCPE100T3C
Continuous
Amperes
MCP Trip
Range (Amperes)
MCP Catalogue
Number
250 500 1000
625 1250
750 1500
HMCPJ250D5L
HMCPJ250F5L
HMCPJ250G5L
875 1750
1000 2000
1125 2250
1250 2500
HMCPJ250J5L
HMCPJ250K5L
HMCPJ250L5L
HMCPJ250W5L
Continuous
Amperes
MCP Trip
Range (Amperes)
MCP Catalogue
Number
600 1125 2250
1500 3000
1750 3500
HMCPL600L
HMCPL600N
HMCPL600R
2000 4000
2250 4500
2500 5000
3000 6000
HMCPL600X
HMCPL600Y
HMCPL600P
HMCPL600M
Continuous
Amperes
Cam
Setting
Motor Full Load
Current Amperes
MCP Trip
Setting
MCP Catalogue
Number
800 A
B
C
D
E
F
G
123.1 184.5
184.6 246.1
246.2 307.6
307.2 369.1
369.2 430.7
430.8 492.2
492.3 553.7
1600
2400
3200
4000
4800
5600
6400
HMCP800X7W
1200 A
B
C
D
E
F
G
184.6 276.8
276.9 369.1
369.2 461.4
461.5 553.7
553.8 646.1
646.2 738.4
738.5 830.7
2400
3600
4800
6000
7200
8400
9600
HMCP12Y8W
September 2005
36
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
30 mA Ground Fault (Earth Leakage) Modules Vol. 1, Ref. No. [036]
30 mA Ground Fault
(Earth Leakage) Modules
Clockwise from Left: GJ, GL, GE
MCCBs Shown with Ground Fault
(Earth Leakage) Modules
Eaton offers a 3- and 4-pole 30 mA
ground fault (earth leakage) protection
module for GE, GJ and GL breakers.
The module does not restrict the use
of other breaker accessories. UL-listed
modules are available for GJ and GL
MCCBs. The IEC-rated GE module
is side mounted for circuits up to
125 amperes, while the GJ and GL
modules are both bottom mounted for
circuits up to 160 and 250 amperes (GJ),
or 400 and 630 amperes for the GL.
The module is completely self-contained
since the current sensor, relay and
power supply are located inside the
product. Current pickup settings are
selectable from 0.03 10 amperes for
all IEC-rated modules and GJ UL-listed
module, and 0.03 30 amperes for
the GL UL-listed modules. Time delays
are also selectable from Instantaneous
1.0 seconds for 0.10 ampere settings
and above. A current pickup setting
of 0.03 amperes defaults to an Instan-
taneous time setting regardless of
the time dials position. Two alarm
contacts come as standard: a 50% pre-
trip and a 100% after trip, both based
only on earth leakage current levels.
Figure 15. UL-Rated GL-Frame Earth Leakage Module Faceplate
Figure 16. IEC-Rated GL-Frame Earth Leakage Module Faceplate
Product Selection
Table 67. GE-Frame Earth Leakage Modules,
IEC (Side Mounted, 230 415 Vac, 50/60 Hz)
Table 68. GJ-Frame Ground Fault Modules,
UL-Rated (Bottom Mounted,
120 480 Vac, 50/60 Hz)
Table 69. GJ-Frame Earth Leakage Modules,
IEC (Bottom Mounted, 230 415 Vac, 50/60 Hz)
Table 70. GL-Frame Ground Fault Modules,
UL-Rated (Bottom Mounted,
120 480 Vac, 50/60 Hz)
Table 71. GL-Frame Earth Leakage Modules,
IEC (Bottom Mounted, 230 415 Vac, 50/60 Hz)
Amperes Poles Catalogue
Number
125
125
3
4
ELESE3125W
ELESE4125W
Amperes Poles Catalogue
Number
150
150
3
4
ELJBN3150W
ELJBN4150W
250
250
3
4
ELJBN3250W
ELJBN4250W
Amperes Poles Catalogue
Number
160
160
3
4
ELJBE3160W
ELJBE4160W
250
250
3
4
ELJBE3250W
ELJBE4250W
Amperes Poles Catalogue
Number
400
400
3
4
ELLBN3400W
ELLBN4400W
600
600
3
4
ELLBN3600W
ELLBN4600W
Amperes Poles Catalogue
Number
400
400
3
4
ELLBE3400W
ELLBE4400W
630
630
3
4
ELLBE3630W
ELLBE4630W
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
37
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Special Features and Accessories Vol. 1, Ref. No. [037]
Special Features and
Accessories
Internal Accessories
Alarm Lockout
The alarm switches operate when
the circuit breaker is tripped by a short
circuit or overcurrent, but also when
it is tripped by a shunt trip or under-
voltage release.
Auxiliary Switches
Auxiliary switches are used for
signaling and control purposes.
The various functions of the auxiliary
switches (changeover) are shown in
Figure 18.
Shunt Trips
The shunt trip is used for remote
tripping.
The coil of the shunt trip is rated only
for short-time operation.
It is not permissible with the circuit
breaker open to apply a continuous
opening command to the shunt trip
in order to prevent the breaker from
closing. This means that interlocking
circuits with continuous commands
may not be set up with shunt trips.
Undervoltage Releases
The circuit breaker cannot be closed
until the undervoltage release is ener-
gized. If the release is not energized,
the circuit breaker can only perform
an idle switching operation.
Frequent idle switching actions
should be avoided as they shorten the
endurance of the circuit breaker.
Accessory Congurations for GE GR Circuit Breakers
Figure 17. Internal Accessory Congurations
Figure 18. Contact Making by the Auxiliary
and Alarm Switches as a Function of the
Switching Position of the Circuit Breaker
September 2005
38
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Special Features and Accessories Vol. 1, Ref. No. [038]
Special Calibration
Special non-UL listed calibrations
are available for certain ambient
temperatures other than 40C and
for frequencies other than 50/60 Hz
or dc. Reduced interrupting ratings
will apply for 400 Hz applications.
50C Calibration
Note: Breakers equipped with electronic trip
units can operate reliably in ambient tem-
peratures of 50C. Add sufx V3 to GN
MCCBs to remove standard 40C labeling.
Add sufx V to catalogue number
for complete thermal magnetic
breaker when ordering listed ampere
ratings for breakers to be used in 50C
ambients. 50C ambient MCCBs are
not UL listed.
Contact Eaton for availability.
Moisture-Fungus Treatment
All Eaton Circuit Breaker cases are
Moulded from glass-polyester which
does not support the growth of fungus.
Any parts which are susceptible to
the growth of fungus will require
special treatment.
Order by description.
Table 72. Calibrations and Treatment
Table 73. External Accessories and Test Kit
Provision only.
Test Kit
Electronic Portable Test Kit
STK2 STK2
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
39
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Accessories Vol. 1, Ref. No. [039]
Table 74. Accessories
A1L5RPK A1L6RPK
2 Make/2 Break Left A2L5LPK
Right ALM2M2BEPK
A2L5RPK A2L6RPK
Auxiliary Switch 1A, 1B Left A1X5LPK
Right AUX1A1BPK A1X5RPK
2A, 2B Left A2X5LPK
Right AUX2A2BPK A2X5RPK A2X6RPK
3A, 3B Left A3X5LPK
Right A3X5RPK
4A, 4B Left
Right A4X6RPK
Auxiliary Switch /Alarm Lockout Left AA115LPK
Right AUXALRMEPK
AA115RPK
Shunt Trip Standard 120 Vac Left SNT120CPK SNT5LP11K
Right SNT6P11K
240 Vac Left SNT120CPK SNT5LP11K
Right SNT6P11K
24 Vdc Left SNT060CPK SNT5LP03K
Right SNT6P03K
48 Vdc Left SNT060CPK SNT5LP23K
Right SNT6P23K
380 600 Vac Left SNT480APK
Right
220 250 Vdc or 380 440 Vac SNT5LP14K SNT6P14K
480 600 Vac SNT5LP18K SNT6P18K
Shunt Trip Low Energy Left LST5LPK
Right LST6RPK
Undervoltage Release Mechanism 120 Vac Left UVR120APK UVH5LP08K
Right UVH6RP08K
208 240 Vac Left UVR240APK UVH5LP11K
Right UVH6RP11K
24 Vdc, Vac Left UVR024CPK UVH5LP21K
Right UVH6RP21K
48 Vdc Left UVR048DPK UVH5LP23K
Right UVH6RP23K
12 Vdc, Vac Left UVR012CPK
Right
48 Vac Left UVR048APK UVHLP05K
Right UVHRP05K
120 Vdc Left UVR125DPK UVHLP26K
Right UVHRP26K
220 250 Vdc Left UVR250DPK UVHLP28K
Right UVHRP28K
380 500 Vac Left UVR480APK UVHLP29K
Right UVHRP29K
525 600 Vac Left UVR600APK
Right
12 Vdc Left UVHLP20K
Right UVH6RP20K
12 Vac Left UVHLP02K
Right UVH6RP02K
Make
Break
a
b
ST
c
UV
September 2005
40
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Plug-in Blocks and Drawout Cassettes Vol. 1, Ref. No. [040]
Plug-in Blocks
Plug-in adapters simplify installation
and front removal of circuit breakers.
Plug-ins are available for rear connec-
tion applications on 3- and 4-pole
circuit breakers. Trip on drawout
interlock kits are included. Stabs for
GE, GJ and GL plug-ins rotate 90 for
exible installation. Use terminal
shields for IP30 protection.
GL Breaker with Plug-in Block
Product Selection
Table 75. Plug-in Blocks
GE
GJ
GL
3, 4
3, 4
3, 4
PIILEG
PIILJG
PIILLG
Terminal Shields IP30
GE
GE
3
4
EFTS3K
EFTS4K
GJ
GJ
3
4
FJTS3K
FJTS4K
GL
GL
3
4
LTS3K
LTS4K
Drawout Cassette
Drawout Cassette
The Drawout Cassette is currently
for use with the standard 3-pole 65
and 100 kA/480 Vac, 1600 ampere and
2000 ampere GR circuit breakers only.
It consists of two separate components:
the movable mechanism which is
factory mounted to the circuit breaker
frame (shown in photo above) and the
stationary mechanism which is housed
in the cassette and shipped separately.
The drawout mechanism has four
positions.
Connected The breaker is fully
connected to the primary stabs and
secondary contacts.
Test The breaker is not connected
to the primary stab but is connected
to the secondary contacts.
Disconnected Both the primary
stabs and the secondary contacts
are disconnected.
Withdraw The breaker can
be removed from the cassette.
Table 76. GR Drawout Cassette
Stationary
Mechanism
RD20DOS (without shutters)
RD20DOSS (with shutters)
100 kA/480 Vac Version
Movable
Mechanism
RD20DOM
Stationary
Mechanism
RD20DOS (without shutters)
RD20DOSS (with shutters)
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
41
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Handle Mechanisms Vol. 1, Ref. No. [041]
Handle Mechanisms
Overview
Handle mechanisms are used to
operate Moulded case circuit breakers,
Moulded case switches and motor
circuit protectors. They are available
in three basic congurations Flange
Mounted, Through-the-Door and
Direct (Close-Coupled) providing
safe, dependable operation and ease
of installation.
Flange Mounted
Flex Shaft
Through-the-Door
Universal Rotary
Direct (Close Coupled)
Universal Direct
Euro IEC
Handle mechanisms are typically used
on enclosed circuit breakers, control
panels and motor control centers
in many different applications. Eaton
Electrical has a handle mechanism
for virtually any need.
Flange Mounted Handle
Mechanisms
The Flex Shaft
Flange Mounted handle mechanisms
mount on the ange of an enclosure
door. The Flex Shaft is an extra
heavy-duty mechanism that includes
a exible shaft in various lengths,
0.9 m (3 feet) through 3 m (10 feet)
for use with various size enclosures.
The Flex Shaft handle will accept up
to three padlock shackles, each with
a maximum diameter of 9.5 mm
(3/8 inch). Can be used with NEMA 12
fabricated enclosures. An optional
handle is available for Flex Shaft
that is suitable for use with NEMA 4
environments.
Flex Shaft comes preset from the
factory, requiring only minor eld
adjustments on installation, which
takes about 10 minutes a signicant
time savings compared to installation
of other types of ange handle mecha-
nisms. The Flex Shaft mechanism
also takes up less interior enclosure
space than competitive designs and
the handle ts standard ange cutouts.
Flex Shaft handle can be remotely
mounted from breaker, where an
operator can use it by funneling
the cable through conduit.
Flex Shaft is UL listed under File
E64893 and meets CSA requirements.
Note: NEMA 4X handle mechanisms are
available. Add Sufx X to the complete
Catalogue Number.
Original narrow handle design
(No C Sufx) is available. Remove C
from Catalogue Number.
Note: When selecting the length of
shaft, ensure minimum bending radius
of 4 inches (101.6 mm) is maintained to
operate properly.
The standard method of shipment
includes the mechanism preset at
the factory; however, minor eld
adjustments may be required.
Flex Shaft Ordering Information
Table 77. Flex Shaft Ordering Information
Note: Add Sufx L to the complete Catalogue Number for 152.4 mm (6-inch) handle.
Flex Shaft Accessories (E- through R-Frame)
Table 78. Standard Door Hardware
(Required Adapter Kit)
Table 79. Door Hardware Adapter Kit
(Required on Standard Door Hardware)
Table 80. NEMA 12 Safety Door
Hardware for Flex Shaft
N/A
N/A
LHMFS04
F5S04CI
F6S04
F5S05CI
F6S05
F5S06CI
F6S06
LHMFS07
N/A
N/A
N/A
N/A
N/A
N/A
LHMFS10
F5S10CI
N/A
Latch Panel Height
in mm (Inches)
Catalogue
Number
2 Point
2 Point
3 Point
Up to 762.0 (30.00 )
Up to 1016.0 (40.00)
Over 1016.0 (40.00)
DH1R
DH2R
DH3R
Description Catalogue Number
Door Hardware
Adapter Kit
AMTDHA
Handle Length
in mm (Inches)
Catalogue
Number
101.6 (4.00)
152.4 (6.00)
C361KJ4
C361KJ6
Roller Latch
C361KR
NEMA
Type
IP
Type
1
3R
12
4/4X
IP20
IP55
IP54
IP66
September 2005
42
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Handle Mechanisms Vol. 1, Ref. No. [042]
Through-the-Door Handle
Mechanisms
Universal Rotary
The Eaton Universal Rotary is suitable
for use with NEMA 12 enclosure
types. An optional NEMA 4/4X handle
mechanism is also available. All rotary
handle mechanisms include a handle
Lock Off, to prevent turning the
breaker ON while in the OFF position.
All Rotary handles indicate ON/OFF/
Tripped/Reset positions, however,
Universal Rotary has the added feature
of international markings for ON (I)
and OFF (O). The Universal Rotary is
made of Moulded material.
The Universal Rotary mechanisms
for GE, GJ and GL MCCBs can be
operated by hand with the door open
or locked off to prevent operation
with the door open.
For the GN-Frame MCCBs, a Eaton
Rotary with a metal handle (Table 83)
is also available.
Table 82. Universal Rotary Ordering
Information
GE-Frame
152.4 (6.00)
304.8 (12.00)
609.6 (24.00)
Black
Black
Black
EHMVD06B
EHMVD12B
EHMVD24B
152.4 (6.00)
304.8 (12.00)
609.6 (24.00)
Red
Red
Red
EHMVD06R
EHMVD12R
EHMVD24R
GJ-Frame
152.4 (6.00)
304.8 (12.00)
609.6 (24.00)
Black
Black
Black
FJHMVD06B
FJHMVD12B
FJHMVD24B
152.4 (6.00)
304.8 (12.00)
609.6 (24.00)
Red
Red
Red
FJHMVD06R
FJHMVD12R
FJHMVD24R
GL-Frame
152.4 (6.00)
304.8 (12.00)
609.6 (24.00)
Black
Black
Black
KLHMVD06B
KLHMVD12B
KLHMVD24B
152.4 (6.00)
304.8 (12.00)
609.6 (24.00)
Red
Red
Red
KLHMVD06R
KLHMVD12R
KLHMVD24R
GN-Frame
152.4 (6.00) Black HMVD5B
GR-Frame
235.0 (9.00) Black HMVD6B
Shaft
Length in
mm (Inches)
Handle
Colour
Complete
Catalogue Number
NEMA
1, 3R, 12
NEMA
4/4X
152.4 (6.00)
304.8 (12.00)
406.4 (16.00)
609.6 (24.00)
Black
Black
Black
Black
WHM5R06
WHM5R12
WHM5R16
WHM5R24
WHM5R06X
WHM5R12X
WHM5R16X
WHM5R24X
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
43
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Handle Mechanisms Vol. 1, Ref. No. [043]
Direct (Close-Coupled)
Handle Mechanisms
Universal Direct (GE GL)
Direct (Close-Coupled) Handle
Mechanisms mount directly to the
circuit breaker. They are used in shal-
low enclosures where the standard
variable depth Through-the-Door type
mechanism is not practical or cannot
be used. They are typically for applica-
tions where high volume, standardized
enclosures are being fabricated.
The Universal Direct handle
mechanism is designed exclusively for
the new Eaton GE, GJ and GL circuit
breakers. It is available as standard
with a door interlock to prevent open-
ing the enclosure while the circuit
breaker is in the ON position. It is also
available without a door interlock.
The Universal Direct handle mecha-
nism is UL 489 listed, IEC 60947-1/2
and meets CSA requirements.
The Euro IEC Direct handle mechanism
is designed for GN and GR MCCBs.
The Euro IEC Direct handle mechanism
is 60947-112.
Table 84. Universal Direct Ordering Information
Table 85. Euro IEC Direct Ordering Information
Frame White Handle Colour Red Handle Colour
with Interlock without Interlock without Interlock
Catalogue Number
GE
GJ
GL
EHMCCBI
JHMCCBI
LHMCCBI
EHMCCB
JHMCCB
LHMCCB
EHMCCR
JHMCCR
LHMCCR
Frame Catalogue Number
Black Handle
GN
GR
HMVD5B
HMVD6B
September 2005
44
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [044]
Time Current Curves
Tripping Characteristics
The operating values specied for
the inverse time overcurrent releases
(thermal overload releases, a
releases) are mean values of the scat-
ter bands of all setting ranges from the
cold state and with uniform current
loading of the conducting paths.
The tripping characteristics of the
instantaneous (electromagnetic) short
circuit releases (n releases) are
based on the rated phase current I
n
which in the case of circuit breakers
with adjustable thermal overload
releases is also the upper value of the
setting range. With a lower setting
current, a correspondingly higher
multiple is obtained for the operating
current of the n release.
Figure 19. Tripping Time Characteristics
(Thermal Memory)
0 1 5
Type GE
Tripping characteristics of GE
circuit breakers for plant protection,
n release xed setting = 400 600 for
breaker 15 45 A; over 50 A = 10x I
n
.
Figure 20. GE Time Current Curve
Type GJ
Tripping characteristics of GJ
circuit breakers for plant protection,
n release adjustable.
Figure 21. GJ Time Current Curve for
Thermal Magnetic Trip Units
Type GL
Figure 22. GL Time Current Curve for Thermal Magnetic Trip Units
100 2 4 6 8 101 2 4 6 8 102 2 4 6 8 103
10000
5000
3000
2000
1000
500
300
200
100
50
30
20
10
5
3
2
1
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
T
I
M
E
I
N
S
E
C
O
N
D
S
CURRENT IN MULTIPLES OF I
n
(a)
50-125
20
25
30-32
15-16
35
40
45 (c)
(d)
Max. Trip Time
Min. Trip
Time
100 2 4 6 8 101 2 4 6 8 102 2 4 6 8 103
10000
5000
3000
2000
1000
500
300
200
100
50
30
20
10
5
3
2
1
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
T
I
M
E
I
N
S
E
C
O
N
D
S
CURRENT IN MULTIPLES OF I
n
(b)
10XIn
(a)
5XIn
Max. Trip Time
Min.
Trip
Time
(c)
(d)
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
45
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [045]
Figure 23. GL Electronic Trip Unit Long Delay Response and Short Delay with I
2
t Response Curve
September 2005
46
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [046]
Figure 24. GL Electronic Trip Unit Long Delay Response and Short Delay with Flat Response Curve
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
47
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [047]
Figure 25. GL Electronic Trip Unit Ground Fault Delay Response Curve
September 2005
48
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [048]
Type GN
Tripping characteristics of GN
circuit breakers with solid-state
overcurrent release.
Working Temperature Range
The tolerance bands shown are appli-
cable to an ambient temperature range
of -5 to +60C at the circuit breaker.
Figure 26. GN Time Current Curve for Digitrip 310 Trip Unit
1 2 3 4 5 6 8 10 15Xl
r
7200
1000
500
200
100
50
20
10
5
2
1
.5
.2
.1
.05
.02
.01
.005
T
I
M
E
I
N
S
E
C
O
N
D
S
CURRENT IN MULTIPLES OF I
n
1.5 10 15 20 30 40 60 80 100 200 kA
Setting for l
d
as Multiples of l
r
(7x l
r
Not Shown)
2X
3X
4X
5X
6X
8X
7 X
Notes:
Inverse-time overload release a
l
r
Set current (adjustable)
Short time delayed short circuit release
l
d
Tripping current (adjustable)
t
d
Delay time (adjustable)
Instantaneous short circuit release n
l
i
Tripping current (fixed setting)
t
d
300 ms
200 ms
100 ms
n
s
a
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
49
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [049]
Figure 27. GN Ground Fault Delay Response Curve for Digitrip 310 Trip Unit
Series G GN Frame Circuit Breakers
The NES Digitrip RMS 310 Trip Units are AC only devices that employ microprocessor based
technology that provides true RMS current sensing means for proper correlation with thermal
characteristics of conductors and equipment. They are used with Circuit Breaker Types GNS,
GNH and GNC.
Curve accuracy applies from -20C to +55C ambient.
Digitrip RMS 300 trip units are suitable for functional field testing with Test Kit Cat. No. STK2.
For field testing using primary injection methods, follow NEMA publication AB-4.
September 2005
50
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [050]
Type GR
Tripping characteristics of GR
circuit breakers with solid-state
overcurrent release.
Working Temperature Range
The tolerance bands shown are appli-
cable to an ambient temperature range
of -5 to +60C at the circuit breaker.
Figure 28. GR Time Current Curve for Digitrip 310 Trip Unit
1 2 3 4 5 6 8 10 15Xl
r
7200
1000
500
200
100
50
20
10
5
2
1
.5
.2
.1
.05
.02
.01
.005
T
I
M
E
I
N
S
E
C
O
N
D
S
CURRENT IN MULTIPLES OF I
n
1.5 10 15 20 30 40 60 80 100 200 kA
Setting for l
d
as Multiples of l
r
(7X l
r
Not Shown)
2X
3X
4X
5X
6X
8X
7 X
t
d
300 ms
200 ms
100 ms
n
s
a
Notes:
Inverse-time overload release a
l
r
Set current (adjustable)
Short time delayed short circuit release
l
d
Tripping current (adjustable)
t
d
Delay time (adjustable)
Instantaneous short circuit release n
l
i
Tripping current (fixed setting)
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
51
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Vol. 1, Ref. No. [051]
Figure 29. GR Ground Fault Delay Response Curve for Digitrip 310 Trip Unit
Series G GR Frame Circuit Breakers
Equipped with Type Digitrip RMS 310 Trip Units for Ground Fault Protection.
They are used with Circuit Breakers Types GRH and GRC.
Curve accuracy applies from -20C to +55C ambient.
Digitrip RMS 310 trip units are suitable for functional field testing with test kit Cat. No. STK2.
For field testing using primary injection methods, follow NEMA publication AB-4.
September 2005
52
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GR Vol. 1, Ref. No. [052]
Current Limiting Curves
Current Limiting Characteristics and Maximum I
2
t Values
Type GE/GJ/GL
Figure 30. Current Limiting Characteristics
for GE to GL, 50/60 Hz 380/415/480 Vac
Type GE/GJ/GL
Figure 31. Current Limiting Characteristics for
GE to GL, 50/60 Hz 600/660/690 Vac
Type GE/GJ/GL
Figure 32. Maximum I
2
t Values for GE to GL,
50/60 Hz 380/415/480 Vac
Type GE/GJ/GL
Figure 33. Maximum I
2
t Values for GE to GL,
50/60 Hz 600/660/690 Vac
Type GN/GR
Figure 34. Current Limiting Characteristics Ip
for GN to GR, 50/60 Hz 380/415/480 Vac
Type GN/GR
Figure 35. Maximum I
2
t Values for GN to GR,
50/60 Hz 600/660/690 Vac
0.3
5 7 10 20 30 50 kA 100
200
kA
100
80
60
40
20
10
8
6
4
2
C
U
T
-
O
F
F
C
U
R
R
E
N
T
I
D
SHORT CIRCUIT CURRENT I
Srms
0.2
E
J
L
cos =0.25
5 7 10 20 30 50 kA 100
200
kA
100
80
60
40
20
10
8
6
4
2
C
U
T
-
O
F
F
C
U
R
R
E
N
T
I
D
SHORT CIRCUIT CURRENT I
Srms
0.3
0.2
E
J
L
cos =0.25
5 7 10 20 30 50 kA 100
100
80
60
40
20
10
6
4
2
1
I
2
t
V
A
L
U
E
X
1
0
5
SHORT CIRCUIT CURRENT I
Srms
L
8
J
E
5 7 10 20 30 50 kA 100
100
80
60
40
20
10
6
4
2
1
I
2
t
V
A
L
U
E
X
1
0
5
SHORT CIRCUIT CURRENT I
Srms
L
8
A
2
s
J
E
5 7 10 20 30 50 kA 100
200
kA
100
80
60
40
20
10
8
6
4
2
C
U
T
-
O
F
F
C
U
R
R
E
N
T
I
D
SHORT CIRCUIT CURRENT I
Srms
0.3
0.2
R
N
0.5
cos =0.25
5 7 10 20 30 50 kA 100
100
80
60
40
20
10
6
4
2
1
I
2
t
V
A
L
U
E
X
1
0
6
SHORT CIRCUIT CURRENT I
Srms
8
A
2
s
N
R
R
N
Notes:
50/60 Hz 380/415 VAC
50/60 Hz 660/690 VAC
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
53
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GE through GJ Vol. 1, Ref. No. [053]
Dimensions
Figure 36. GE-Frame Dimensions in mm (Inches)
Figure 37. GJ-Frame Dimensions in mm (Inches)
Front View 3-Pole Front Cover Cutout SideView
70.4
(.77)
77.0
(3.03)
139.7
(5.50)
3.6 (.14) R
47.0
(1.85)
33.0 Dia.
(1.30)
23.9 (0.94)
22.9
(0.90)
11.9 (0.47)
C
L
CC
76.2
(3.00)
Handle
C
L
CC
Breaker
Front View 3-Pole Front Cover Cutout SideView
104.9
(4.13)
31.8 (1.25)
16.0 (0.63)
4.8 (0.19) R
87.4
(3.44)
177.8
(7.00)
100.3
(3.95)
(4.00)
77.7
(3.06)
52.1 (2.05)
27.0 (1.06)
12.7
(0.50)
C
L
CC
Handle
7.1 (0.28)
101.6
September 2005
54
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Sizes GL through GR Vol. 1, Ref. No. [054]
Figure 38. GL-Frame Dimensions in mm (Inches)
Note: TA63IL, T63IL, T632L, TA632L terminals add 30.2 mm (1.19 inches) to line or load side of GL. LTS3K or LTS4K terminal covers add
54.1 mm (2.13 inches) to line or load side of GL.
Figure 39. GN-Frame Dimensions in mm (Inches)
141.7
(5.58)
257.3
(10.13)
103.1
(4.06)
139.2
(5.48)
48.8
(1.92)
61.7
(2.43)
80.3
(3.16)
6.4 R
(0.25)
50.8
(2.00)
68.3
(2.69)
136.7
(5.38)
BREAKER
4-Pole
235.0
(9.25)
C
L
CC
Breaker
Front View 3-Pole Front Cover Cutout
406.4
(16.00)
87.4 (3.44)
6.4 (0.25) R
Side View
C
L
CC
Handle
139.7
(5.50)
209.6
(8.25)
43.6 (1.72)
96.7
(3.81)
38.1 (1.50)
162.1
(6.38)
81.0 (3.19)
4.8 (0.19) R
September 2005
PG01200003E For more information visit: www.EatonElectrical.com
55
Series G Moulded Case Circuit Breakers
15 2500 Amperes for IEC & NEMA Applications
Frame Size GR Vol. 1, Ref. No. [055]
Figure 40. GR-Frame Dimensions in mm (Inches)
368.3
(14.50)
184.2
(7.25)
(5.10)
(7.75)
4.1 R
(0.16)
Front View 3-Pole Front Cover Cutout
C
L
Breaker
406.4
(16.00)
209.6
(8.25)
393.7
(15.50)
333.5
(13.13)
166.9
(6.57)
(9.70)
381.0
(15.00)
4 Holes
11.2 Dia.
(0.44)
C
L
Handle
330.2
(13.00)
57.2 (2.25)
Tee
Connectors
May Be
Rotated 90
171.5
(6.75)
228.6
(9.00)
Side View
11.2 R
(.44)
129.5
246.4
196.9
September 2005
56
For more information visit: www.EatonElectrical.com PG01200003E
Series G Moulded Case Circuit Breakers
Vol. 1, Ref. No. [056]
Notes
2005 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. PG01200003E / Z3680
October 2005
Eaton Electrical Inc.
1000 Cherrington Parkway
Moon Township, PA 15108
United States
For more information or to locate
regional product support, please visit
us at www.EatonElectrical.com
Eatons electrical business is a global leader in electrical
control, power distribution, and industrial automation products
and services. Through advanced product development, world-
class manufacturing methods, and global engineering services
and support, Eatons electrical business provides customer-
driven solutions under brand names such as Cutler-Hammer,
Powerware, Durant, Heinemann, Holec and MEM, which
globally serve the changing needs of the industrial, utility,
light commercial, residential, and OEM markets. For more
information, visit www.EatonElectrical.com.
Eaton Corporation is a diversified industrial manufacturer with
2004 sales of $9.8 billion. Eaton is a global leader in electrical systems
and components for power quality, distribution and control; fluid
power systems and services for industrial, mobile and aircraft equipment;
intelligent truck drivetrain systems for safety and fuel economy; and
automotive engine air management systems, powertrain solutions
and specialty controls for performance, fuel economy and safety.
Eaton has 57,000 employees and sells products to customers in more
than 125 countries. For more information, visit www.eaton.com.