GE Circuit Breakers
GE Circuit Breakers
GE Circuit Breakers
imagination at work
1882
First Arc Blast Arrester
1894
1918
1935
AE and AL Oilfilm Trip Devices
1946
AK-1 Breaker and EC-1 Trip Device
1955
AK-2 Stored Energy Design and EC-2 Trip Device
1960
AKD-5 Switchgear
1966
AK-3 Static Power Sensor Trip Breaker
1971
AKE, AKL Replacement D/O Breaker
First High First MetalVoltage, Oil Clad Immersed Switchgear Switch/Circuit Breaker
Operating buttons: ON/OFF Breaker status contacts: OPEN/CLOSED Closing spring status: CHARGED/DISCHARGED
Rating plug
Accessories
There are more than 20 different types of factory installed and loose accessories available for the EntelliGuard G circuit breaker. Whether its a bell alarm contact, key interlock or redundant shunt trips, we have the accessory combinations to meet your need! Factory-Installed Accessories Motor Operators Closing Devices Shunt Trip for Ground Fault UVR with Fixed Time Delay Second Shunt Trip or UV Release Auxiliary Switches & Contacts Bell Alarm & Trip Annunciation Trip Annunciation Breaker Mounted Key Interlocks Mechanical Interlocks Fixed Breakers Mechanical Interlocks Drawout Breakers Network Interlock
Shipped Loose Accessories Carriage Position Switch Coil Signaling Contact Module Contact Wear Indicator Door Interlock Electrical Close Switch Lock Kits Lifting Truck Mechanical Operation Counter Pushbutton Padlock Device Ready-to-Close Switch Secondary Disconnect Block Spring Charged Contact UVR Time Delay Modules Bell Alarm Contact
1977
AKD-6 Switchgear with AKR Breakers ECS, SST Solid State Trip Devices
1978
AKJ-50/T50 Replacement Breakers
1980
AKD-8 Switchgear and MVT-9 Trip Unit
1985
AKR-30S Breaker
1986
RMS9 and Epic Trip Units
1993
1994
1998
WavePro Breaker and AKD-10 Switchgear
2005
EntelliGuard Breaker and Entellisys Switchgear
2008
EntelliGuard G Breaker, EntelliGuard TU Trip Unit and AKD-20 Switchgear
Power Leader AKR-125 Products 5000A with MVT Breaker Plus and PM Trip Unit
Here are some of the ways that is accomplished: Multiple Short Time bands under 100ms optimally fit above the Instantaneous clearing times. Alternate Instantaneous setting (RELT) mitigates arc flash hazard while maintaining complete selectivity during normal operation. Remote activation can be safely achieved with off-the-shelf devices or, for networked systems, RELT can be activated via the communications port. RELT annunciation can be direct or indirect, either locally on the equipment or remotely via control devices or the industrial network. Adjustable ST and GF Zone Selective Interlocking optimizes restrained and unrestrained bands. Zone Selective Instantaneous protection, multiple zone protection, 3 cycle clearing and selectivity are provided simultaneously. Instantaneous trip adjusts up to 30X trip plug rating.
X X X X
X X X
UL489
Interrupting Rating Tier UL 489 Devices, ICCB Type 240V 480V 600V 1/2S Withstand S 65,000 65,000 50,000 42,000 N 65,000 65,000 65,000 42,000 H 85,000 85,000 65,000 50,000 P 100,000 100,000 65,000 50,000 M 100,000 100,000 100,000 65,000 L 150,000 150,000 100,000 85,000 Envelope 1 400-1200 400-2000 X X X X Envelope 2 2500-3000 400-3000 X X X X X X Envelope 3 3000 4000-6000
NOTE: GE internal quality testing requirements exceeded 20,000 mechanical and electrical operations.
NOTE: GE internal quality testing requirements exceeded 20,000 mechanical and electrical operations.
DC Ratings
Envelope 2 Type M Amps 800-3000 Rated Endurance (Operations) Short Interrupting Minimum Mechanical Minimum Electrical Minimum Electrical Current (A) Endurance Endurance at 600 VDC Endurance at 1000 VDC 30,000 12,500 500 500
imagination at work
DEA-462B (05/12)