Psychrometric Process
10. You are designing an evaporative cooling system to
ventilate a controlled environment, totally enclosed,
poultry house in a hot and dry climate.
Summer design weather conditions for your location
are 40 degree C Tdb and 20 % RH.
75 m
3
/s of outdoor air will be drawn by the evaporative
cooling system (75% efficiency) and 15 m
3
/s of outdoor
air will be drawn into the house through infiltration.
The birds in the house are expected to produce 250
kW of total heat of which 40% is latent heat. Determine
a) the psychrometric properties of the air mixed by air through
evaporative cooling pad and air through infiltration.
b) the psychrometric properties of the exhausted air.
c) the volumetric flow rate of air exhausted from the house.
d) the rate (L/s) at which water must be supplied to the evaporative
cooling pads by a water pump. When a (water flow/evaporation
rate) ratio of 3 is desire.
75 m
3
/s
4
3
1
2
15 m
3
/s
Evaporative
cooler
infiltration
Poultry
House
State 1
State 2
State 3
= 16.66, = 86.3, = 102.96 kg/s
T
3
= ( * T
1
+ * T
2
) / = 28.69 deg. C
W
3
=( * W
1
+ * W
2
) / = 0.0137 kg/kg
Zoom out
1
M
-
1
M
-
1
M
-
2
M
-
2
M
-
2
M
-
3
M
-
3
M
-
3
M
-
= 75 m
3
/s
v
2
= 0.8689 m
3
/kg
= 86.3 kg/s
4 3
1
2
= 15 m
3
/s
v
1
= 0. 9003 m
3
/kg
= 16.66 kg/s
Evaporative
cooler
infiltration
Poultry
House
T
1
= 40 deg. C
RH
1
= 20 %
W
1
= 0.0092 kg/kg
T
2
= 26.51 deg. C
RH
2
= 67.1 %
W
2
= 0.0146 kg/kg
T
3
= 28.69 deg. C
W
3
= 0.0137 kg/kg
= 102.96 kg/s
100 kW latent
150 kW
sensible heat
AT = 150 / ( * Cp) = 150 /
(102.96*1.006) = 1.448 deg. C
h
fg
= 2501 2.42 * (28.69+1.448)
= 2428 kJ/kg
AW= 100 / ( * h
fg
) = 100 /
(102.96 * 2428) = 0.0004 kg/kg
T
4
= T
3
+ AT = 28.69 + 1.448
= 30.138 deg. C
W
4
= W
3
+ AW = 0.0137 +
0.0004 = 0.0141 kg/kg
3
M
-
1
M
-
2
M
-
M
-
M
-
1
V
-
2
V
-
Zoom in to the limit.
State 3
State 4
s m
M V
M M
/ 47 . 90 8787 . 0 * 96 . 102 *
3
4
4 4
3 4
= = =
=
- -
- -
v
The volumetric flow rate
and properties of states 3 and 4
the rate (L/s) at which water must
be supplied to the cooling pad =
3 * (0.0146 0.0092) * 75 /
0.9003 = 1.3495 kg /s
Reference
Albright, L.D. 1990. Chapter 2
Psychrometrics. Environment Control for
Animals and Plants. An ASAE Textbook.