The inspection report summarizes the condition of parts from a steam turbine. Key findings include corrosion on the turbine rotor shaft, missing impeller key, corroded impeller and casing, and missing bolts. Recommendations are made to clean parts, repair threads, apply new coatings, and manufacture replacement keys. Work done includes cleaning, dimensional inspections, and repairs. Spare parts are also listed.
The inspection report summarizes the condition of parts from a steam turbine. Key findings include corrosion on the turbine rotor shaft, missing impeller key, corroded impeller and casing, and missing bolts. Recommendations are made to clean parts, repair threads, apply new coatings, and manufacture replacement keys. Work done includes cleaning, dimensional inspections, and repairs. Spare parts are also listed.
The inspection report summarizes the condition of parts from a steam turbine. Key findings include corrosion on the turbine rotor shaft, missing impeller key, corroded impeller and casing, and missing bolts. Recommendations are made to clean parts, repair threads, apply new coatings, and manufacture replacement keys. Work done includes cleaning, dimensional inspections, and repairs. Spare parts are also listed.
The inspection report summarizes the condition of parts from a steam turbine. Key findings include corrosion on the turbine rotor shaft, missing impeller key, corroded impeller and casing, and missing bolts. Recommendations are made to clean parts, repair threads, apply new coatings, and manufacture replacement keys. Work done includes cleaning, dimensional inspections, and repairs. Spare parts are also listed.
: PT. Duta Marine TYPE : Force Draft Fan Righ hand
EQUIPMENT : Steam Turbine Location : KN Kakap Natuna : KKK TURBINE QUANTITY : 1 unit Introduction: The Pump has been Inspected on november 03 to 16,2012 at PT Duta Marine /Kakap Natuna, for inventory parts required for completely assemble, After inspecting was done (visual, dimensional, ), generally all Part was found to be corroded Some Parts was found to be missing . The detail incoming inspection as below : No. Qty A. Turbine Rotor Rotor Shaft Finding : - Was found to be medium Corroded and shaft - Corrosion was found on shaft sleeve - Key Coupling was found to be missed Recommend : - Cleaning and record actual mechanical run out - Balancing may required due to missing coating and/or recoating 1 area - Manufacture for new Impeller key Action taken -Dimensionally and visually inspect fill off and filled off Impeller Rotor Finding : - Was found to be filled off ceramic coating - Corrosion was found on shaft sleeve and impeller - Impeller Key was found to be missed Recommend : - Cleaning to remove corroded and apply new painting - All Threads need to be repair Action taken -Dimensionally and visually inspect SUMMARY OF INSPECTION REPORT J OB NO CUSTOMER OEM As Received Turbine Rotor Description Inspection/Recommendation Work Scope 1 2 1 set FMP-10/10 // Rev 0 // 08-05-2008 Page 1 of 9 No. Qty CASING CONE Finding : - was found to be corroded condition Recommend : - Cleaning to remove corroded and apply new painting 1 unit - All Threads need to be repair Action taken -Dimensionally and visually inspect COUPLING Finding : - was found to be Corroded surface Recommend : - Cleaning to Remove corrosion 1 area - Remove High metals for an excellent performance balance with rotor Action taken - Cleaning and Reused it IMPELLER - Impeller during cleaning process Recommend : - Mechanical cleaning by blasting 1 area - And re-coating Action taken - Cleaning by sand papers Cardan Finding : - was found to be Corroded surface - Missing Casing Bolts 44 ea and center bolts 6 Ea Recommend : - Perform Repair for Cleaning and chase Threads Action taken - Cleaning mating surfaces and chase threads Inner Casing During cleaning Finding : - mating Surfaces dirt and existing silicon embodied - Corrosion was found on volutes areas - Missing three Bolts and no gasket Recommend : - Cleaning - Coating and painting Action taken - Cleaning No. Qty 4 SUMMARY OF INSPECTION REPORT Description Inspection/Recommendation Work Scope 3 5 6 1 set 7 1 set SUMMARY OF INSPECTION REPORT Description Inspection/Recommendation Work Scope FMP-10/10 // Rev 0 // 08-05-2008 Page 2 of 9 CASE RING Finding : - was found to be corroded condition Recommend : - Cleaning to remove corroded and apply new painting 2 PLCS - surfaces was found to be scored Action taken - Cleaning - Dimensionally and visually inspect New Bearing Housing Finding : - Mating Part functionally check for compatible Recommend : - Dimensionally inspect for for mating fitting with 2 PLCS - Remove High metals Action taken - Dimensionally and visually inspect IMPELLER LOCK NUT Finding : - All SURFACES l was found to be Eroded Recomm : - Cleaning and remove high metals 1 PLC Action taken - Cleaning NEW BEARING COVER Finding : - Mating Part functionally check for compatible Recomm : - Dimensionally inspect for for mating fitting with - Remove High metals Action taken - Dimensionally and visually inspect NO QTY 1 AISI 1045 44 2 AISI 1045 44 3 AISI 1045 44 4 AISI 1045 8 5 AISI 1045 8 7 ID. 80 MM X 2 MM TEBAL SUS 410 2 8 M 20 X 2 X 15 PANJ ANG SUS 410 2 9 OD.128 ; ID. 80.5 X 20 MM BRONZE 1 10 OD.100 ; ID. 80.7 X 20 MM BRONZE 1 11 OD. 100; ID 80 SPRING RUBBER 2 12 20 X 14 X 120MM PANJ ANG AISI 1045 1 3 4 5 6 2 PLC NAMA BARANG STUD BOLT SELF LOCKING NUT WASHER HEXAGON BOLT NUT AND WASHER LOCK WASHER IMPELLER LOCK NUT DISTANCE RING SHAFT RING LIP SEAL KEY M20 MATERIAL KEBUTUHAN SPARE PART BALLAS PUMP NO. 1 UKURAN M24X3X 83 MM PANJ ANG M24X3 M24 M20 FMP-10/10 // Rev 0 // 08-05-2008 Page 3 of 9