Hatch Data Sheet
Hatch Data Sheet
Hatch Data Sheet
Flow
Hach sc200
Universal Controller
with Ultrasonic Flow Sensor
Product Overview
The sc200 Universal Controller with Ultrasonic Sensor
is designed to give highly accurate flow and depth
measurements for your open channel flow monitoring
applications.
From the easy-to-read display to reliable data management
with SD card data transfer, the flow system provides an
economical choice for flow monitoring.
The flow system can be used for a variety of applications
including NPDES permitting requirements and the monitoring
of storm water, inlet flow, final effluent and activated sludge.
It replaces the Hach GLI53 analog controller with advanced
features for easier operator use.
The sc200 controller platform can be configured to operate
either 2 Digital Sensor Inputs, or 1 or 2 Analog Sensor Inputs,
or a combination of Digital and Analog Sensor Inputs.
Customers may choose their communication options from
a variety of offerings ranging from MODBUS RTU to
Profibus DPV1.
DW
WW
PW
IW
Maximum Versatility
Analog Inputs
4-20 mA Outputs
Total of six (6) 4-20 mA outputs (2 std/4 optional)
enables up to 3 mA outputs per sensor input
Digital Communication
Display
Large display with scrolling menus for easy set up
Transreflective display stays readable even in sunlight
Data Management
SD Card simplifies data transfer
Standardized accessories for max compatibility
Sensor Inputs
Simplifies analog sensor connections
Works with GLI and Hach digital sensors
Specifications*
sc200 General Specifications
Display
Graphic dot matrix LCD with LED backlighting
Transreflective
Display Size
48 x 68 mm (1.89 x 2.67 in.)
Display Resolution
240 x 160 pixels
Height x Width x Depth
144 x 144 x 181 mm (5.7 x 5.7 x 7.1 in.)
Weight
1.70 kg (3.75 lb)
Power Requirements
100 240 Vac 10%, 50/60 Hz
24 Vdc -15% + 20%
Operating Temperature
-20 to 60C (-4 to 140F), 0 to 95% RH non-condensing
Digital Communication
MODBUS RS232/RS485, Profibus DPV1 optional
Memory Backup
Flash memory
Electrical Certifications
EMC: CE compliant for conducted and radiated emissions
CISPR 11 (Class A limits), EMC Immunity EN 61326-1
(Industrial limits)
Safety: General Purpose UL/CSA 61010-1 with cETLus
safety mark
Storage Temperature
-20 to 70C (-4 to 158F), 0 to 95% RH non-condensing
Depth
0-1200.0 inches, 0-100.0 feet, 0-30,000 mm,
or 0-30.00 meters
Input Filter
999 sec
Operational Mode
Primary or secondary measurement or calculated value
(dual channel only)
Totalizers
8-digit resettable LCD software totalizer
Functional Mode
Linear, Logarithmic, Bi-linear, PID
Totalized Flow
Gal., ft.3, acre-ft., lit., m3
Repeatability
0.1% of span
Sensor-to-Controller Distance (max)
100 m (328 ft.)
Calibration Methods
Cal Depth 1 point
Cal Depth 2 point
Enclosure Rating
NEMA 4X / IP 66
Conduit Openings
1/2" NPT Conduit
Relays
Four electromechanical SPDT (Form C) contacts, 1200W,
5 A, 250 Vac
Operational Mode
Primary or secondary measurement, calculated value
(dual channel only) or timer
Functional Mode
Alarm, Timer, Feeder Control, PWM or FM Control,
System Alarm
Engineering Specifications
The controller shall be a microprocessor based instrument.
2. The enclosure shall be 1/2 DIN format, NEMA4X rated for
wall, pole and panel mounting.
Dimensions
The sc200 controller unit can be installed on a surface, panel, or pipe (horizontally or vertically). No tools are needed to connect
the controller unit to any Hach digital sensor. NOTE: Dimensions are in inches [millimeters].
Minimum Spacing Dimensions for Group Mounting
Mounting Dimensions
Bottom View
Ordering Information
sc200 Controller and Module Smart Part Numbering System
LXV404.99. X X X X X
Power
No power cord
No power cord Type-Oinstalled strain reliefs
With EU power cord installed with cord grip
With UK power cord installed with cord grip
With US power cord installed with cord grip
24VCD power supply with no cord or cord grips
Communications Output
Standard (two 4-20mA outputs)
MODBUS 285 & 485
Profibus DP
HART + four 4-20mA analog outputs
Four additional 4-20mA analog outputs
Sensor Input 1
pH & DO
Conductivity
Flow
mA input
Digital
Sensor Input 2
None
pH & DO
Conductivity
Flow
mA input
Digital
Brand
Hach Lange
Hach
Keep it pure.
0
1
2
3
5
7
Make it simple.
Be right.
0
1
3
5
9
1
2
3
4
5
Power Cords
9202900
9203000
Accessories
9220600
8809200
1000G3088-001
9218200
9218100
0
1
2
3
4
5
1
2
For France
HACH LANGE FRANCE, S.A.S.
8, mail Barthlmy Thimonnier
77185 LOGNES cedex
Telephone: 0 820 20 14 14 (In France)
(+33)(1) 69 67 34 00 (General)
Fax: (+33)(1) 69 67 34 99
E-mail: info@hach-lange.fr
www.hach-lange.fr
For Spain
HACH LANGE, S.L.U.
Edif. Arteaga Centrum
C/Larrauri, 1C, 2 Pl.
E-48160 Derio/Vizcaya
Telephone: (+34) 94 657 33 88
Fax: (+34) 94 657 33 97
E-mail: info@hach-lange.es
www.hach-lange.es
For Great Britain
HACH LANGE, LTD.
Pacific WaySalford
Manchester, M50 1DL
Telephone: (+44) 161 872 1487
Fax: (+44) 161 848 7324
E-mail: info@hach-lange.co.uk
www.hach-lange.co.uk