DATA SHEET

Flow

Hach sc200
Universal Controller
with Ultrasonic Flow Sensor
Product Overview
The sc200 Universal Controller with Ultrasonic Sensor
is designed to give highly accurate flow and depth
measurements for your open channel flow monitoring
applications.
From the easy-to-read display to reliable data management
with SD card data transfer, the flow system provides an
economical choice for flow monitoring.
The flow system can be used for a variety of applications
including NPDES permitting requirements and the monitoring
of storm water, inlet flow, final effluent and activated sludge.
It replaces the Hach GLI53 analog controller with advanced
features for easier operator use.
The sc200 controller platform can be configured to operate
either 2 Digital Sensor Inputs, or 1 or 2 Analog Sensor Inputs,
or a combination of Digital and Analog Sensor Inputs.
Customers may choose their communication options from
a variety of offerings ranging from MODBUS RTU to
Profibus DPV1.

New sc200 Controller when combined with the Ultrasonic


Flow Sensor offers accuracy and time-saving features
for your open channel flow monitoring applications.

DW
WW
PW

Features and Benefits

IW

Maximum Versatility

Analog Inputs

Standardized controller eliminates the need for a variety


of dedicated controllers

Enables non-sc analyzer monitoring

Multi-channel controller operates either 1 or 2 sensors


reducing inventory holding costs and providing an
inexpensive option to add a second sensor at a later time
Plug and Play operation with all Hach digital sensors
True dual sensor controller provides 4-20 mA outputs to
transmit primary and secondary measurement values

Accepts mA signals from other analyzers for local display


Consolidates analog mA signals to a digital output

4-20 mA Outputs
Total of six (6) 4-20 mA outputs (2 std/4 optional)
enables up to 3 mA outputs per sensor input

Digital Communication
Display
Large display with scrolling menus for easy set up
Transreflective display stays readable even in sunlight

Data Management
SD Card simplifies data transfer
Standardized accessories for max compatibility

Sensor Inputs
Simplifies analog sensor connections
Works with GLI and Hach digital sensors

MODBUS 232/485 and Profibus


DP V1.0

Ease of Use and Confidence


in Results
New display and guided
calibration procedures reduce
operator error
Password protected SD card
reader offers a simple solution for
data download and transfer
Visual warning system provides
critical alerts

DW = drinking water WW = wastewater municipal PW = pure water / power


IW = industrial water E = environmental C = collections FB = food and beverage

Specifications*
sc200 General Specifications
Display
Graphic dot matrix LCD with LED backlighting
Transreflective
Display Size
48 x 68 mm (1.89 x 2.67 in.)
Display Resolution
240 x 160 pixels
Height x Width x Depth
144 x 144 x 181 mm (5.7 x 5.7 x 7.1 in.)
Weight
1.70 kg (3.75 lb)
Power Requirements
100 240 Vac 10%, 50/60 Hz
24 Vdc -15% + 20%
Operating Temperature
-20 to 60C (-4 to 140F), 0 to 95% RH non-condensing

Digital Communication
MODBUS RS232/RS485, Profibus DPV1 optional
Memory Backup
Flash memory
Electrical Certifications
EMC: CE compliant for conducted and radiated emissions
CISPR 11 (Class A limits), EMC Immunity EN 61326-1
(Industrial limits)
Safety: General Purpose UL/CSA 61010-1 with cETLus
safety mark

UltraSonic Flow Sensor


Flow Rate
0-9999, 0-999.9, 0-99.99 with selectable flow rate units
and multiplier
Volume
0-9,999,999 with selectable volume units

Storage Temperature
-20 to 70C (-4 to 158F), 0 to 95% RH non-condensing

Depth
0-1200.0 inches, 0-100.0 feet, 0-30,000 mm,
or 0-30.00 meters

Analog Output Signal


Two 0/4 to 20 mA isolated current outputs, max 500

Input Filter
999 sec

Operational Mode
Primary or secondary measurement or calculated value
(dual channel only)

Totalizers
8-digit resettable LCD software totalizer

Functional Mode
Linear, Logarithmic, Bi-linear, PID

Totalized Flow
Gal., ft.3, acre-ft., lit., m3

Optional 4 additional 4/20 mA isolated current outputs,


max 500 @ 18-24 Vdc (customer-supplied power source)
Security Levels
Two password protected levels
Enclosure Materials
Polycarbonate, Aluminum (powder coated), Stainless Steel
Mounting Configurations
Wall, pole and panel mounting

Repeatability
0.1% of span
Sensor-to-Controller Distance (max)
100 m (328 ft.)
Calibration Methods
Cal Depth 1 point
Cal Depth 2 point

Enclosure Rating
NEMA 4X / IP 66
Conduit Openings
1/2" NPT Conduit
Relays
Four electromechanical SPDT (Form C) contacts, 1200W,
5 A, 250 Vac
Operational Mode
Primary or secondary measurement, calculated value
(dual channel only) or timer
Functional Mode
Alarm, Timer, Feeder Control, PWM or FM Control,
System Alarm

*Specifications subject to change without notice.

Engineering Specifications
The controller shall be a microprocessor based instrument.
2. The enclosure shall be 1/2 DIN format, NEMA4X rated for
wall, pole and panel mounting.

7. The controller shall have options for MODBUS RS232,


MODBUS RS485 and Profibus DPV1 communication.
8. The display contrast shall be adjustable.

3. The controller shall offer both 100240 Vac 50/60 Hz and


24 Vdc power options.

9. The Menu shall be available in at least 19 different


languages.

4. The controller shall offer two analog 0/4-20 mA output


signals with independent PID control functions and
optional four additional 4-20 mA outputs.

10. The controller shall have 2 Data logs, 128 kb each.


The logged data shall be downloadable on a SD card
in XML format.

5. The controller shall accept the Sensor Module for the


Ultra Sonic Flow sensor.

11. The flow meter shall be Hach Company sc200 Flow


Controller with Ultrasonic Sensor.

6. The controller shall have single channel and dual channel


options.

Dimensions
The sc200 controller unit can be installed on a surface, panel, or pipe (horizontally or vertically). No tools are needed to connect
the controller unit to any Hach digital sensor. NOTE: Dimensions are in inches [millimeters].
Minimum Spacing Dimensions for Group Mounting

Mounting Dimensions

Bottom View

Ordering Information
sc200 Controller and Module Smart Part Numbering System

Old U53 Sensor


0 0 3 0 2

LXV404.99. X X X X X
Power
No power cord
No power cord Type-Oinstalled strain reliefs
With EU power cord installed with cord grip
With UK power cord installed with cord grip
With US power cord installed with cord grip
24VCD power supply with no cord or cord grips
Communications Output
Standard (two 4-20mA outputs)
MODBUS 285 & 485
Profibus DP
HART + four 4-20mA analog outputs
Four additional 4-20mA analog outputs
Sensor Input 1
pH & DO
Conductivity
Flow
mA input
Digital
Sensor Input 2
None
pH & DO
Conductivity
Flow
mA input
Digital
Brand
Hach Lange
Hach

Keep it pure.

0
1
2
3
5
7

Make it simple.
Be right.

For current price information,


technical support, and ordering
assistance, contact the Hach office
or distributor serving your area.

0
1
3
5
9

In the United States and all countries


except Europe, contact:
HACH COMPANY
4539 Metropolitan Court
Frederick, MD 21704-9452, U.S.A
Telephone: (800) 368-2723
Fax: 301-874-8459
E-mail: hachflowsales@hach.com
www.hachflow.com

1
2
3
4
5

Ultrasonic sensor with 10 ft. cable


Ultrasonic sensor with 30 ft. cable
Ultrasonic sensor with 100 ft. cable

Power Cords
9202900
9203000

sc200 power cord with strain relief, 125 Vac


sc200 power cord with strain relief, 230 Vac, European-style plug

Accessories
9220600
8809200
1000G3088-001
9218200
9218100

In Europe for all countries except


France, Spain and Great Britain:
FLOW-TRONIC
Rue J.H. Cool 19a
B-4840 Welkenraedt, Belgium
Telephone: +32-87-899797 or 899799
Fax: +32-87-899790
E-mail: info@flow-tronic.com
www.flow-tronic.com

0
1
2
3
4
5

Ultrasonic Flow Sensors


U53S010
U53S030
U53S100

At Hach, its about learning from


our customers and providing the
right answers. Its more than
ensuring the quality of water
its about ensuring the quality of
life. When it comes to the things
that touch our lives...

sc200 Weather and Sun Shield with UV Protection Screen


sc200 UV Protection Screen
Weather Protection Cover
SD card reader (USB) for connection to PC
4 GB SD card

Lit. No. 2767


L10 Printed in U.S.A.
Hach Company, 2010. All rights reserved.
In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time.

1
2

For France
HACH LANGE FRANCE, S.A.S.
8, mail Barthlmy Thimonnier
77185 LOGNES cedex
Telephone: 0 820 20 14 14 (In France)
(+33)(1) 69 67 34 00 (General)
Fax: (+33)(1) 69 67 34 99
E-mail: info@hach-lange.fr
www.hach-lange.fr
For Spain
HACH LANGE, S.L.U.
Edif. Arteaga Centrum
C/Larrauri, 1C, 2 Pl.
E-48160 Derio/Vizcaya
Telephone: (+34) 94 657 33 88
Fax: (+34) 94 657 33 97
E-mail: info@hach-lange.es
www.hach-lange.es
For Great Britain
HACH LANGE, LTD.
Pacific WaySalford
Manchester, M50 1DL
Telephone: (+44) 161 872 1487
Fax: (+44) 161 848 7324
E-mail: info@hach-lange.co.uk