Cleo Brochure 2015
Cleo Brochure 2015
Cleo Brochure 2015
CLEO
PORTABLE
weighs less than 3 lbs
TOUCHSCREEN
easy and intuitive to use
MOBILE
backup battery powered
Field Upgradeable
THERMOMETER
Infinium Capnotrack
The Infinium Capnotrack capnography system is a cutting
edge low flow End-tidal CO2 measuring system.
The
Capnotrack uses a 50/ml per minute sidestream method to
Mounting Solutions
A RELIABLE CONNECTION
ROLLING STAND
Height and tilt adjustable with a large wheel base
allows for smooth and stable mobility.
n
n
n
n
WALL MOUNTS
Height and tilt adjustable wall mounts offer.
n
n
n
n
Class I (on AC power) , internally powered equipment (on battery power):Per I.E.C. 60601-1, clause 2.2.4
Type BF, defibrillation-proof CF - Applied part
70% isopropyl alcohol solution or a nonstaining disinfectant.
Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide
Continuous
IPXO
APPLICATION
NETWORKING
Temperature
Measurement Range:
Typical
Measurement Times:
(after insertion
into measurement site):
Wired Networking:
Wireless Networking:
PERFORMANCE SPECIFICATIONS
Display:
Resolution:
Trace:
Waveforms:
Indicator:
Trend time:
NIBP
Measuring Technology: Automatic oscillating measurement
Cuff Inflating: <30s (0 ~ 300 mmH, standard
adult cuff)
Measuring Period: AVE<40s
Mode: Manual, Auto, STAT
Measuring Interval
in AUTO Mode: 2 min ~ 4 hrs
Pulse Rate Range: 30 bpm ~ 250 bpm
Measuring Range: Adult/Pediatric Mode
SYS: 40 ~ 250 (mmHg)
DIA: 15 ~ 200 (mmHg)
Neonatal Mode
SYS: 40 ~ 135 (mmHg)
DIA: 15 ~ 100 (mmHg)
Resolution: 1mmHg
Pressure Accuracy: Maximum Mean error: 5mmHg
Maximum Standard
deviation: 8mmHg
Overpressure Protection: Adult Mode: 280(mmHg)
Neonatal Mode: 150 (mmHg)
Alarm Limit: SYS: 50 ~ 240 mmHg
DIA: 15 ~ 180 mmHg
Standards: Meets performance standards of
ANSI/AAMI SP10:2002
SPO2
ASpO2:
SpO2% Range:
SpO2 Accuracy:
Pulse Rate Range:
Pulse Rate Accuracy:
Alarm Upper-lower Limit:
SpO2 Probe:
Anti-motion SpO2
0 ~ 100%
2% (70 ~ 100%,non-motion)
3% (70 ~ 100%, motion)
30-250 bpm
2 bpm(non-motion),
3 bpm (motion)
Upper limit 70 ~ 100%,
Lower limit 70 ~ 100%
Red light LED wavelength:
660nm5nm
Infrared light LED wavelength:
940nm10nm
Standards: Meets performance standards
of EN ISO 9919:2005
Pulse Timer:
Patient Accuracy:
Batteries:
Standards:
EtCO2 (OPTION)
Industry standard:
802.11b/g wired network
Frequency Range:
2.412 ~ 2.484 GHz
Connected bedside number:
Up to 16 bedside monitors
Up to 100m indoors
Industry standard 802.11b/g wireless
Supports TCP/IP and UDP/IP Protocols
POWER
ENVIRONMENTAL SPECIFICATIONS
Temperature: Operating: 5 ~ 40 C
Storage: -10 ~ 45 C
Humidity Range: Operating: 80 %
Storage: 80 %
FUSE
3.15A/250V
LCD SPECIFICATIONS
Display Type:
Size (diagonal):
Active Area:
Color arrangement:
Dot pitch:
Display Mode:
Interface:
Surface Treatment:
TOUCHSCREEN SPECIFICATIONS
Type: Four-Wire Analog Resistive Touch Panel
Input Mode: Stylus Pen or Finger
Connector: FPC
Insulation resistance: 25M
Voltage: 7VDC
Chattering: 10ms
Transparency: 80%
Surface hardness: 3H
Durability-surface scratching: Write 100,000
Active force: 80gf
Knock Test: 1,000,000 times
ISO 13485