Insulate

Seal
Protect

Communications Products

Table

of

Contents

Communication Products
CFSP/CFRP.............................................................................................................................3
Fiber optic splice protector
CFTV......................................................................................................................................5
Adhesive lined tubing for splice and connector protection
CFTV QuickSeal....................................................................................................................7
Adhesive wraparound sleeve for environmental sealing without disconnection
CGEL......................................................................................................................................9
Gel filled closures for environmental protection of coaxial drop splices
CTB-15.................................................................................................................................11
Self fusing tape
DROP...................................................................................................................................13
Drop tubing

Communication Products
Unique Solutions for Broad Band Communications
DSG-Canusa is the leading manufacturer of outside plant protection products
for broad band communications.
Our innovative products prevent water ingress and mechanical damage to
cables, splices and connectors.

USA: 800.422.6872

Canada: 800.845.6808

www.dsgcanusa.com

CFSP/CFRP
Insulate
Seal
Protect

Fiber Optic Splice Protector


A specially designed cross-linked polyolefin tubing system, with meltable liner, providing strength and protection
to optical fiber splices

Features

and

Benefits

Single fiber and ribbon fiber splice protector available


Single holed (preshrunk) ends eliminate improper fiber threading
Smooth, de-burred stainless steel reinforcing member ends decrease the risk of fiber damage during
installation

Extended liner length prevents contact between the fiber and the backbone
Clear sleeve design permits easy centering of splice before heating
Continuous operating temperature: -40C to 60C
Shrink temperature: 90C

Standards

GR-1380 compliant

Typical Applications

Protection of fusion splices in optical networks

CFSP/CFRP

Fiber Optic Splice Protector

Dimensions
Order Number

Nominal Sleeve Length


mm

Inside Diameter of Inner Liner


(min.)

Nominal Support Rod Diameter*

Packaging

in

mm

in

mm

in

pieces/bag

Number of
Splices

CFSP Single Fiber Protectors


CFSP-12-61

61.0

2.40

1.5

0.06

1.2

0.05

100

CFSP-12-45

45.0

1.77

1.5

0.06

1.2

0.05

100

CFSP-12-23

23.0

0.90

1.5

0.06

1.2

0.05

100

1.57

3.0

0.12

1.8

0.07

50

CFRP Ribbon Fiber Protector


CFRP-12

40.0

12

*Support rod for CFSP is made from stainless steel


*Support rod for CFRP is made from ceramic

Ordering

Refer to the table to select the CFSP/CRFP with the desired sleeve length for overlap on each end of the area
to be covered.

Order Example: CFSP-12-61


Packaging: CFSP: 100 pieces per bag; CFRP: 50 pieces per bag
Please contact your Customer Service Representative for information on custom colours, sizes, lengths and
material data sheet.
All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information
presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse
of the product.

USA: 800.422.6872

Canada: 800.845.6808

www.dsgcanusa.com

CFTV

3:1
Shrink Ratio

Insulate
Seal
Protect

Heat Shrink Cable Sleeves


Heat shrink tubing and adhesive liner combination that established the CATV industry standard for splice and
connector protection

Features








and

Benefits

Shrink ratio: 3:1


Craft friendly installation
Exceptional split resistance
CFTV adhesive retains bond providing long term protection
Selective strippability to meet CATV industry specifications
Minimal heat required to produce error free installation without splitting
Thermochromatic lines change colour to signal waterproof seal
Shrinks and seals in half the time of alternative products
Continuous operating temperature: -55C to 110C

Typical Applications

Strain relief of coaxial connectors


Waterproof protection of CATV connectors

CFTV

Heat Shrink Cable Sleeves


Dimensions
Expanded
Order Number

Recovered

Internal Diameter (min.) D


mm

in

0400

10.2

0.40

0750

19.0

1100

27.9

1300

Internal Diameter (max.) d


mm

Wall Thickness (nom.) W

Application Range
Use

for

General

Lengths

in

mm

in

mm

in

in

3.8

0.15

0.08

4.5 - 8.5

.18 - .34

1.2

48

0.75

5.6

0.22

0.08

6.0 - 16.5

.24 - .65

1.2

48

1.10

10.2

0.40

0.08

11.5 - 25.0

.45 - 1.0

1.2

48

33.0

1.30

10.2

0.40

0.08

11.5 - 30.0

.45 - 1.2

1.2

48

1500

38.1

1.50

12.7

0.50

0.08

14.0 - 35.0

.55 - 1.4

1.2

48

1700

43.2

1.70

12.7

0.50

0.08

14.0 - 40.0

.55 - 1.6

1.2

48

2050

52.1

2.05

19.0

0.75

0.08

21.0 - 45.0

.82 - 1.8

1.2

48

2750

69.8

2.75

25.4

1.00

0.08

30.0 - 63.0

1.2 - 2.5

1.2

48

Ordering

Select a dimension which will shrink snugly over the component to be covered. If recovery is restricted the
resulting wall thickness will be less than specified.

Order Example: CFTV, 1700


Please contact your Customer Service Representative for information on custom sizes, lengths and material data
sheet.
All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information
presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse
of the product.

USA: 800.422.6872

Canada: 800.845.6808

www.dsgcanusa.com

CFTV QuickSeal

>3:1
Shrink Ratio

Insulate
Seal
Protect

Heat Shrink Wraparound Sleeve


Heat shrink wraparound sleeve with adhesive for complete environmental sealing without the need for
disconnection. Ideal for the protection of housing to housing connectors, retrofit protection of exposed
connectors and the repair of damaged cable or fiber

Features








and

Benefits

Shrink ratio: >3:1


Fast and simple installation without interruption of service
Repair squirrel damaged cable
Proven CANUSA CFTV adhesive ensures an absolutely waterproof seal
Selective strippability to meet CATV industry specifications
Minimal heat required to produce error free installation without splitting
Thermochromatic lines that change colour upon correct shrink temperature
CFTV QuickSeal can be cut to size in field to suit application
Continuous operating temperature: -55C to 110C

Typical Applications

Repair damaged cable and fiber


Retrofit protection of connectors without disconnecting

CFTV QuickSeal

Heat Shrink Wraparound Sleeve

Dimensions
Order
Number

Length

Expanded Internal Diameter


(max.) D

Width

Recovered Internal
Diameter (max.) d

Recovered Wall Thickness


(nom.) W

in

mm

in

mm

in

mm

in

mm

in

mm

36

914

178

1.7

43

0.55

14

0.06

1.5

229

178

1.7

43

0.55

14

0.06

1.5

Installation Notes

CFTV QuickSeal is a one size fits all solution that can accommodate all sizes of cable and connectors.

CFTV QuickSeal can be cut to length and width in the field to fit the specific application. Simply wrap
CFTV QuickSeal around the cable or connector, ensuring adequate overlap, and then firmly apply the
closure to hold CFTV QuickSeal together during the heat shrinking process. Please refer to the installation
instructions included with each CFTV QuickSeal for more detailed information.

Ordering

Please specify the product name plus the options you require.
Order Example: CFTV QuickSeal, 1, 36 in length
Please contact your Customer Service Representative for information on custom sizes, lengths and material data
sheet.
All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information
presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse
of the product.

USA: 800.422.6872

Canada: 800.845.6808

www.dsgcanusa.com

CGEL
Insulate
Seal
Protect

Drop Splice Enclosure


Gel filled closures are a simple, fast and effective method for providing complete environmental protection for
coaxial drop splices

Features



and

Benefits

Single piece, clam shell design, requires no additional tools for installation
Gel filled for complete waterproof protection
Expansion chambers prevent Gel overflow
Accommodates a wide range of environmentally sealed coaxial connectors and cable types including
quad shielded cable

Available in two sizes:


- CE 596 for 59 and 6 series cable

- CE 711 for 7 and 11 series cable

Channel provided to retain messenger cable


Fully re-enterable
Tough outer shell withstands impacts to 5 ft-lb
Withstands extreme temperatures (-45C to
90C

Standards

Meets SCTE IPS-TP-013 (ANSI/SCTE 60

2004) requirements for water immersion and


temperature cycling

Typical Applications

Environmental protection of cable splices

CGEL

Drop Splice Enclosure

Dimensions
Order Number

Nominal Diameter

Lengths

mm

in

mm

in

CE 596

25.4

1.0

116

4.6

CE 711

31.0

1.2

165

6.5

Applicable Cables
Cables: All 59 and 6 series coaxial cables including quad shield with messengers

All 7 and 11 series coaxial cables including quad shield with messengers

Connectors
59

and

6 Series

and

11 Series

DIGCON

D2, Type II and S

D2, S and RG 11

T&B

F Series
SNS Series

SNS Series

Corning GILBERT

GF Type
AHS, UltraEase and Ultra Range

GAF
AHS, UltraEase and Ultra Range

PPC

CMP, EX and AquaTight EX

EX and AquaTight EX

Others

F-Conn, Stirling

F-Conn, Stirling

Ordering

Please specify the product name plus the options you require.
Order Example: CGEL, CE 596
Packaging: 12 pieces per box
All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information
presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse
of the product.

USA: 800.422.6872

Canada: 800.845.6808

www.dsgcanusa.com

10

CTB-15
Insulate
Seal
Protect

Self Fusing Tape


EPR based self fusing tape designed for the Communications industry

Features






and

Benefits

Provides protection where heat/flame is prohibited


Covers any shape including high transition areas and elbows
Clean strippable
Layers fuse together to form a boot that provides complete environmental protection and insulation
UV and ozone resistant
Proven long term protection
Continuous operating temperature: -40C to 90C

Typical Applications

Environmental protection of connectors in tight


locations or when torch is not permitted

Protect connectors in Cable TV, Wireless and


Telecom applications

11

CTB-15

Self Fusing Tape

Dimensions
Order Number

CTB-15

Width

Thickness

Roll Length

mm

in

mm

in

ft

38.1

1.5

0.76

0.03

4.57

15

Application Instructions



The surface of cable and connector should be clean.


Start the tape on cable approximately two inches from connector.
Make sure the tape is stretched during application.
While stretching the tape, make one wrap on cable ensuring the tape is wrapped onto itself as it will only
adhere to itself. Continue wrapping the cable and connector using half overlap layers.

To terminate, wrap the tape onto itself and place your thumb at the termination point and stretch the tape until
it breaks.

Two layers are recommended


The loose end of the termination should be thumbed down.

Ordering

Please specify the product name plus the options you require.
Order Example: CTB-15
All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information
presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse
of the product.

USA: 800.422.6872

Canada: 800.845.6808

www.dsgcanusa.com

12

DROP

3:1
Shrink Ratio

Insulate
Seal
Protect

Drop Tubing
Thin wall heat shrink tubing provides excellent environmental protection and insulation for CATV drop connectors

Features







and

Benefits

Shrink ratio: 3:1


Meltable inner liner encapsulates cable and connection completely
Excellent UV and ozone resistance
Resistant to all fluids and solvents
Accommodates all F-Connectors and cables
Flexible
Continuous operating temperature: -55C to 110C
Shrink temperature: 120C

Typical Applications

Sealing of coaxial drop connectors

13

DROP

Drop Tubing
Dimensions
Expanded
Order
Number

Recovered

Internal Diameter (min.) D

Internal Diameter (max.) d

Wall Thickness (nom.) W

Meltable Wall Thickness


(nom.)

Lengths

mm

in

mm

in

mm

in

mm

in

in

0500

12.7

0.50

5.0

0.19

1.4

0.05

0.9

0.03

1.2

48

0750

19.1

0.75

8.0

0.31

1.7

0.06

1.0

0.04

1.2

48

Ordering

Select a dimension which will shrink snugly over the component to be covered. If recovery is restricted the
resulting wall thickness will be less than specified.

Options:
Colour: Black (BK), Blue (BL)
Order Example: DROP Tubing, 0500, black, unprinted
Please contact your Customer Service Representative for information on custom colours, sizes, lengths and
material data sheet.
All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information
presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse
of the product.

USA: 800.422.6872

Canada: 800.845.6808

www.dsgcanusa.com

14

Americas
DSG-Canusa, a division of ShawCor Inc.
173 Commerce Blvd.
Cincinnati, Ohio 45140
USA
Toll Free:
Telephone:
Fax:
eMail:

800 422 6872


513 683 7800
513 683 7809
sales@dsgcanusa.com

Canada / Asia Pacific


DSG-Canusa, a division of ShawCor Ltd.
25 Bethridge Road
Toronto, Ontario M9W 1M7
Canada
Toll Free:
Telephone:
Fax:
eMail:

800 845 6808


416 743 7111
416 743 7752
sales@dsgcanusa.com

Europe / Middle East / Africa


DSG-Canusa GmbH & Co. KG
HeidestraBe 5
D-53340, Meckenheim
Germany
Telephone:
Fax:
eMail:

www.dsgcanusa.com

49 0 22 25/88 92-0
49 0 22 25/88 92-44
sales@dsg-canusa.de

November 2007

You might also like