Atkinson Dynamics
Atkinson Dynamics
Atkinson Dynamics
Model AD-56
Model AD-27
Model AD-57
12 VDC
24VDC
120VAC, 50/60 Hz
240VAC, 50/60 Hz
8.0 Watts
11.7 Watts
11.3 Watts
11.3 Watts
20.0 Watts
39.6 Watts
28.8 Watts
30.5 Watts
1.47 A
1.65 A
0.240 A
0.127 A
Temperature
-31F to 150F
-31F to 150F
-31F to 150F
-31F to 150F
Shipping Weight
10 lbs.
10 lbs.
10 lbs. 11 oz.
10 lbs. 11 oz
Dimensions
See Figure 20
See Figure 20
See Figure 20
See Figure 20
Ratings
Supply Voltage
Audio Power
Output (Max.)
Power Consumption
(Max.)
Operating Current
(nominal)
Operating
Table 1
-1-
Function/Feature
Call button
Master mode
Slave mode
Number Group
-1
Remote power
-2
-3
-4
-6
-7
-8
Miscellaneous
-M22
-M34
-M44
MASTER UNITS:
C Models default to Master, or speaker, mode. In Master mode, the unit acts as a speaker and
broadcasts audio signals generated elsewhere in the intercom system. Depressing the Talk switch
turns the unit into a microphone and enables the user to broadcast to all other intercoms in the
system. Releasing the switch returns the unit to Master mode. Figure 4 illustrates a Master/Slave
intercom system.
SLAVE UNITS:
D Models default to Slave, or microphone, mode. In Slave mode, the unit is designed to serve
as a hands-free microphone with transmission to all Master units in the intercom system. The
Slave unit will act as a speaker and broadcast audio transmissions only when the Talk switch of
any Master unit in the intercom system is depressed. Figure 4 illustrates a Master/ Slave intercom
system.
CALL BUTTON:
A Models are equipped with a Call switch. Depressing the call switch transmits an 890Hz tone
to all units in the intercom system.
CAUTION
The call signal is louder than normal voice messages being carried on the line. Do not depress the
call switch while carrying on a conversation with someone on the system. This will subject the
listener to very loud sound levels.
The volume of the call signal is affected by the volume control on the receiving unit, so if volume is
turned all the way down at a receiving station, the call signal will not be heard.
MICROPHONE:
-7 Hand-Held Noise Cancelling Microphones are recommended for use in environments with
high levels of ambient noise. Keying the microphone overrides the default mode of the intercom
and enables audio transmission to all Master units in the intercom system. Figure 2 illustrates a
common intercom system where hand-held microphones are used.
-2-
B. Unpacking.
After unpacking the Atkinson Dynamics Intercom, examine it for damage that may have
occurred in transit. If the equipment has been damaged, do not attempt to install or operate it,
and file a claim immediately with the carrier stating the extent of the damage. Carefully check
all envelopes, shipping labels and tags before removing or destroying them.
Before attempting to install the intercom, be sure that all parts listed in the KIT CONTENTS
LIST have been supplied.
C. Kit Contents List.
Qty.
1
Description
Resistor, 1K, 1W
Part Number
101216
D. Mounting.
CAUTION
The selection of the mounting location for the device, its controls and the routing of the wiring
is to be accomplished under the direction of the facilities and the safety engineer.
NOTE
Intercoms supplied with flexible cords for connection to field wiring are not intended
for permanent mounting.
The intercom is intended to be mounted on any relatively flat and rigid surface by the two
mounting ears on the exterior of the housing. Figure 9 is a dimensional outline drawing
showing the proper mounting configuration. The two mounting ears are 13/32" diameter holes
spaced 5.68" apart. Hardware for mounting the intercom to the surface shall be provided by the
installer.
WARNING
This unit is heavy and should be mounted on a rigid surface capable of supporting the weight
of the intercom.
WARNING
For shipboard applications, installations shall be in accordance with the United States Coast Guard,
Title 46 CRF, Parts 110-113.
For units using the noise cancelling hand-held microphone, install the supplied microphone
mounting clip on any rigid surface near the intercom. Avoid locating the microphone where it
may be exposed to excessive moisture or dust.
E. Electrical Connections.
Plug each intercom into a nearby power source with a protective earth grounding. The plug
should remain readily accessible for disconnection. Connect the audio inputs in parallel.
Audio wires should be sized properly by your licensed installation electrician for your
specified application.
Optional: A 1K, 1W resistor is included in a kit with each intercom. Installing the resistor
across the audio lines helps to reduce noise in certain environments. Only one resistor needs to
be installed on the lines for any system installation.
See figures 1 through 19 for typical intercom connections and wiring information.
-4-
F. Service.
1. General.
Federal Signal will service your equipment or provide technical assistance with any
problems that cannot be handled locally.
Any units returned to Atkinson Dynamics for service, inspection, or repair must be
accompanied by a Return Material Authorization. This R.M.A can be obtained only from the
factory by calling (888)751-1500.
At this time a brief explanation of the service requested or the nature of the malfunction,
should be given.
Address all communications and shipments to:
ATKINSON DYNAMICS
Service Department
2645 Federal Signal Drive
University Park, IL 60466-3195
-5-
2. Replacement Parts.
WARNING
Replace fuse with GMC-1/2 only. DO NOT substitute.
Description
Belt switch assembly
Connector, 3-Position (12/24V PC Boards)
Cover plate gasket
Fuse, GMC-1/2
Headset assembly
Knob, volume control
Microphone assembly
PC Board, 120VAC
PC Board, 120VAC, w/headset
PC Board, 12V, AD-26
PC Board, 12V, AD-26-7
PC Board, 12V, AD-26-8
PC Board, 12V, AD-26-8-M44
PC Board, 12V, AD-26A
PC Board, 12V, AD-26C
PC Board, 12V, AD-26D
PC Board, 12V, AD-26SA-25
PC Board, 240VAC
PC Board, 240VAC, w/headset
PC Board, 24V, AD-26SA-25
PC Board, 24V, AD-56
PC Board, 24V, AD-56-8
PC Board, 24V, AD-56-8-M44
PC Board, 24V, AD-56A
PC Board, 24V, AD-56C
PC Board, 24V, AD-56D
PC Board, 120VAC, -1 Models
PC Board, 240VAC, -1 Models
Kit, potentiometer w/ on/off switch
Kit, push button switch (12/24V models)
Kit, push button switch (120/240V models)
Resistor, 1K, 1W
Rubber boot, push button switch
Rubber boot, toggle switch
Rubber boot, volume control
Kit, toggle switch, DPDT
Kit, potentiometer, 10K Ohm
Kit, toggle switch, 3PDT (AD-27A-M34 & AD-27A-4-M34 only)
Kit, toggle switch, 3PDT
Kit, pushbutton switch, 3PDT
Kit, potentiometer, 1K Ohm
Voice Coil/Diaphragm Assembly-Series C
Part Number
K137146B
K140411A-03
K8590013B
K148A155A
K137145A
K141A129A
K137144A
K2001875B
K2001875B-M34
K2001878B
K2001878B-06
K2001896B-01
K2001896B
K2001878B-05
K2001878B-01
K2001878B-02
K2001878B-17
K2001875B-01
K2001875B-01M34
K2001878B-19
K2001878B-07
K2001896B-03
K2001896B-02
K2001878B-12
K2001878B-08
K2001878B-09
K2001885A
K2001885A-01
K8590236A
K8590242A
K8590241A
K101216A
K288697A
K288696A
K288A542A
K8590238A
K8590237A
K122342A
K8590239B
K8590288A
K8590289A
K8590181A
G. Warranty.
Atkinson Dynamics guarantees their intercoms to be free of defects at the time of delivery. If
damage is found to be a factory defect, Atkinson Dynamics will warrant all labor charges for
repair for one full year, and all replacement parts for two full years.
-6-
-7-
BLK
WHT
GRN
SEE POWER
CONNECTIONS
WHT
BLK
AUDIO CABLE
1WATT
1K
BLK
WHT
GRN
REMOTE B
WHT
BLK
AUDIO CABLE
290A3693
TO OTHER INTERCOMS
Reminders:
Before installing remote intercoms, precautions should be taken to prevent feedback
between two or more remotes in close proximity and acoustically reflective areas.
1620 gauge low voltage audio cable. Twisted pair not required..
Shielded audio cable not required unless operating in high electromagnetic fields. Ground
one end of the shield to earth ground.
Type of power cable depends on intercom model.
7 foot provided for audio and power.
AUDIO LINE
REMOTE A
Remote A
AD-26
AD-27
AD-56
AD-57
Remote B
AD-26A
AD-27A
AD-56A
AD-57A
POWER CONNECTIONS:
BLK
+DC Power
12/24V Models
HOT
120/240V
Models
WHT
Common
12/24V Models
Neutral
120/240V
Models
GRN
Earth Ground
120/240V
Models only
Power
1218VDC
120V 50/60Hz
22-30VDC
240V 50/60Hz
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Talk/Listen Switch
4. Call Tone Switch
Operating Principle:
When one talks, all intercoms will hear.
To talk to other stations, press the talk/
listen switch and speak into the speaker/
microphone.
Release talk switch to listen.
SEE POWER
-8-
BLK
WHT
GRN
WHT
BLK
1K
1WATT
COMMON
AUDIO
BLK
WHT
GRN
WHT
BLK
REMOTE B
Reminders:
Before installing remote intercoms, precautions should be taken to prevent feedback between
two or more remotes in close proximity and acoustically reflective areas.
1620 gauge low voltage audio cable. Twisted pair not required.
Shielded audio cable not required unless operating in high electromagnetic fields. Ground one
end of the shield to earth ground.
Type of power cable depends on intercom model.
7 foot (2 meter) cable provided for audio and power.
TO OTHER
REMOTES
* CONNECTIONS
REMOTE A
290A3694
Remote A
AD-26-7
AD-27-7
AD-56-7
AD-57-7
POWER CONNECTIONS:
BLK
+DC Power
HOT
WHT
Common
Neutral
GRN
Earth Ground
Power
1218VDC
120V 50/60Hz
22-30VDC
240V 50/60Hz
12/24V Models
120/240V Models
12/24V Models
120/240V Models
120/240V
Models only
Remote B
AD-26A-7
AD-27A-7
AD-56A-7
AD-57A-7
Operating Principle:
When one talks, all remotes will hear.
To talk, press talk switch and speak into speaker/
microphone. Release talk switch to listen.
To talk into hand-held microphone, press talk switch
on microphone and speak into microphone element.
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker volume control
3. Talk/Listen switch
4. Call Tone push button switch
5. #137144 hand-held, noise cancelling microphone
with push-to-talk switch
SEE POWER
-9-
BLK
WHT
GRN
* CONNECTIONS
REMOTE A
BLK
WHT
GRN
3/16-20 AWG
1WATT
1K
WHT
BLK
(+) DC POWER
GRN
COMMON
AUDIO
REMOTE B
290A3695
AD-27-1
AD-57-1
Remote A
Remote B
AD-26-1
POWER CONNECTIONS:
BLK
+DC Power
12/24V Models
HOT
120/240V Models
WHT
Common
12/24V Models
Neutral
120/240V Models
GRN
Earth Ground
120/240V
Models only
Power
Not applicable
120V 50/60Hz
240V 50/60Hz
Operating Principle:
When one talks, the other stations will hear.
To talk into the intercom, press the talk switch
and speak into the speaker/microphone.
Release to listen.
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker volume control
3. Talk/Listen Switch
-10-
BLK
WHT
GRN
BLK 3
CONTROL
GRN 1
BLK
1K
WHT 2
1
WATT
AUDIO
BLK
WHT
GRN
COMMON
GRN
WHT
MASTER "B"
BLK
WHT
GRN
BLK 3
WHT 2
GRN 1
SLAVE
Master A
AD-26C-7
AD-27C-7
AD-56C-7
AD-57C-7
Master B
AD-26C
AD-27C
AD-56C
AD-57C
Slave
AD-26D
AD-27D
AD-56D
AD-57D
290A3696
POWER CONNECTIONS:
BLK
+DC Power
12/24V Models
HOT
120/240V Models
WHT
Common
12/24V Models
Neutral
120/240V Models
GRN
Earth Ground
120/240V
Models only
Power
1218VDC
120V 50/60Hz
22-30VDC
240V 50/60Hz
* CONNECTIONS
SEE POWER
MASTER "A"
Operating Principle:
Masters normally listen to slave.
Slave talks to master hands-free,
without having to press a talk switch.
When any master talks, slave hears.
Other masters will hear.
To talk into master, press talk switch
and speak into speaker/microphone.
Release talk switch to listen.
To talk into hand-held microphone,
press talk switch on microphone and
speak into microphone element.
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker volume control
3. Press-to-talk Switch
4. #137144 hand-held, noise cancelling
microphone
5. 3-conductor/1622 gauge cable. Use
shielded cable in electrically noisy
areas. Ground one end of the shield to
earth ground. Ground chassis of DC
unit to ground.
-11COMMON
WHT
1
WATT
1K
AUDIO
BLK
BLK
WHT
GRN
WHT
BLK
290A3702
TO OTHER
INTERCOMS
Remote A
AD-26A-M34
AD-27A-M34
AD-56A-M34
AD-57A-M34
POWER CONNECTIONS:
BLK
+DC Power
12/24V Models
HOT
120/240V Models
WHT
Common
12/24V Models
Neutral
120/240V Models
GRN
Earth Ground
120/240V
Models only
Power
1218VDC
120V 50/60Hz
22-30VDC
240V 50/60Hz
BLK
WHT
GRN
* CONNECTIONS
SEE POWER
REMOTE
Operating Principle:
When one talks, all remotes will hear.
To talk into remote, press talk switch and talk
into speaker/microphone. Release talk switch
to listen. (The headset speaker selector switch
must be in speaker position to hear received
audio signal on speaker.)
To talk into headset, press belt talk switch
and talk into headset microphone. Release belt
switch to listen. (The selector switch must be
in headset position.)
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker volume control
3. Talk/Listen switch
4. Headset/Speaker selector switch
5. Call push button switch
6. #137146 Belt switch w/15 foot cord
7. #137145 Headset w/noise cancelling
microphone
6
POWER CONNECTIONS:
BLK
+DC Power
12/24V Models
HOT
120/240V Models
WHT
Common
12/24V Models
Neutral
120/240V Models
GRN
Earth Ground 120/240V
Models only
REMOTE
SLAVE
STATION
1
NOTES
1. Speaker/Microphone
2. Off/On Speaker Volume Control
3. Talk/Listen Switch
4. Remote Slave Station
Model AD-SV-25
Operating Principle:
1. Slave station is both a speaker and a microphone.
2. Master is normally in Listen mode
until the talk button is pressed to talk to remote.
3. Volume controls are for received signal volume only.
They do not control transmitted signals.
WHT 2
BLK 1
POWER
12-18VDC
22-32VDC
120V 50/60 Hz
MASTER
AD-26-8
AD-56-8
AD-27-8
MASTER
1
200 FT. MAX.
AUDIO
COMMON
1K
1WATT
SEE POWER
* CONNECTIONS
*
BLK
BLK
WHT
GRN
WHT
290A3742B
-12-
SPEAKER
5
BLK 1
WHT 2
MASTER
1
200 FT. MAX.
AUDIO
COMMON
1K
1WATT
SEE POWER
BLK
* CONNECTIONS
*
WHT
BLK
WHT
GRN
290A3743B
Operating Principle:
1. Slave station is both a speaker and a microphone.
2. Master is normally in Listen mode until the talk button is pressed to talk to remote.
3. Outgoing and incoming volumes are controlled by separate controls on master.
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker volume control
3. Talk/Listen switch
4. Outgoing Volume Control
5. Speaker Model AD-SS-25 with swivel mounting
bracket or Speaker Model AD-SF-25 with holes
in outer flange for flush mounting
POWER CONNECTIONS:
BLK
+DC Power
12/24V Models
HOT
120/240V Models
WHT Common
12/24V Models
Neutral
120/240V Models
GRN
Earth Ground
120/240V
Models only
POWER
12-18VDC
22-32VDC
120V 50/60 Hz
240V 50/60 Hz
-13-
MASTER
AD-26-8-M44
AD-56-8-M44
AD-27-8-M44
AD-57-8-M44
-14-
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume
Control
3. Press-to-Talk Switch
4. #137144 Hand-held, noisecancelling microphone with
push-to-talk switch
Operating Principle:
1. Masters normally listen to
slave.
2. Slave talks to masters
hands-free, without having to
press a talk switch.
3. When any master talks, slave
hears. Other master will hear.
4. To talk into master, press talk
switch and speak into speaker/
microphone. Release talk
switch to listen.
5. To talk into hand-held
microphone, press talk switch
on microphone and speak into
microphone element.
( )
POWER
12-18VDC
22-32VDC
POWER
(+)
MASTER "A"
MASTER A
AD-26C-1-7
AD-56C-1-7
MASTER B
AD-26C-1
AD-56C-1
CONTROL
COMMON
RED
WHT
+ DC POWER
BLK
AUDIO
GRN
SLAVE
AD-26D-1
AD56D-1
1WATT
1K
MASTER "B"
WHT 4
RED 3
BLK 2
GRN 1
WHT 4
RED 3
BLK 2
GRN 1
SLAVE
290A3744
SEE POWER
-15-
TO OTHER
INTERCOMS
BLK
WHT
GRN
* CONNECTIONS
REMOTE A
WHT
BLK
1K
1WATT
COMMON
AUDIO
BLK
WHT
GRN
WHT
BLK
REMOTE B
RED
GRN
290A4065
AD-26
AD-27
AD-56
AD-57
Remote A
POWER CONNECTIONS:
BLK
+DC Power
HOT
WHT
Common
Neutral
GRN
Earth Ground
12-18VDC
120V 50/60Hz
22-30VDC
240V 50/60Hz
Power
12/24V Models
120/240V Models
12/24V Models
120/240V Models
120/240V Models only
AD-26-2
AD-27-2
AD-56-2
AD-57-2
Remote B
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Talk/Listen Switch
4. Customer-Supplied External Normally-Open Talk/Listen
Switch, Momentary (e.g., foot switch)
Operating Principle:
When one talks, all intercoms will hear.
To talk to other stations, press the talk/listen switch and speak
into the speaker/microphone. Release talk switch to listen.
To use external talk switch, close switch and speak into the
speaker/microphone.
SEE POWER
BLK
WHT
GRN
* CONNECTIONS
MASTER "A"
-16-
BLU
RED
POWER CONNECTIONS:
BLK
+DC Power
HOT
WHT
Common
Neutral
GRN
Earth Ground
BLK
GRN
WHT
BLK
WHT
GRN
BLK
WHT
GRN
MASTER "B"
1
WATT
1K
BLK
WHT
GRN
COMMON
BLK
WHT
GRN
SLAVE
CONTROL
AUDIO
12/24V Models
120/240V Models
12/24V Models
120/240V Models
120/240V Models only
290A4066
Power
12-18VDC
120V 50/60Hz
22-30VDC
240V 50/60Hz
Master A
AD-26C-2
AD-27C-2
AD-56C-2
AD-57C-2
Master B
AD-26C
AD-27C
AD-56C
AD-57C
Slave
AD-26D
AD-27D
AD-56D
AD-57D
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Press-To-Talk Switch
4. Customer-Supplied External Normally-Open PressTo-Talk Switch, Momentary (e.g., foot switch)
Operating Principle:
Masters normally listen to slave.
Slave talks to master hands-free, without having to
press a talk switch.
When any master talks, slave hears. Other masters
will hear.
To talk into master, press talk switch and speak into
speaker/microphone. Release talk switch to listen.
Master A can talk by pressing either the talk switch
or external switch (customer supplied).
10
-17*
BLK
WHT
GRN
**
BLK
RED
TALK
TALK COM.
WHT
LISTEN COM.
*
GRN
BLK
WHT
GRN
LISTEN
**
Operating Principle:
1. Master can select (via master switch box) to talk to any one or more remotes.
2. Any remote can initiate a call to Master regardless of selector switch being on
or off. Remote must specify its location. Remotes cannot talk to other
remotes.
3. To talk into intercom, press talk switch and speak into speaker/microphone.
Release talk switch to listen.
4. For Master to talk to remote, select desired remote via selector switch, press
talk switch on handset microphone and talk into handset microphone.
NOTES:
1. Desk Set speaker (microphone is mounted on handset)
2. Desk Set speaker volume control
3. Handset earpiece volume control (mounted on back of case)
4. Speaker/Microphone
5. Off/On/Speaker volume control
6. Talk/Listen switch
7. Call Tone Switch
8. Master switch box customer supplied
9. DPDT selector (toggle) switch customer supplied
POWER
REMOTE RA REMOTE RB REMOTE RC
12VDC
AD-26-6
AD-26A-6
AD-26T-6
120V 50/60Hz AD-27-6
AD-27A-6
AD-27T-6
240V 50/60Hz AD-57-6
AD-57A-6
AD-57T-6
** Refer to remote model number as an example for Master.
POWER CONNECTIONS:
BLK +DC POWER 12/24V Models
HOT
120/240V Models
WHT Common
12/24V Models
Neutral
120/240V Models
GRN Earth Ground 120/240V Models only
TO OTHER REMOTES
SEE POWER
* CONNECTIONS
RC
RB
RA
LISTEN
GRN
LISTEN
LISTEN COM.
WHT
TALK COM.
BLK
TALK
GRN
RED
LISTEN COM.
TALK COM.
BLK
WHT
TALK
LISTEN COM.
LISTEN
TALK COM.
TALK
RED
WHT
GRN
BLK
RED
REMOTE RB
BLK
WHT
GRN
BLK
WHT
GRN
REMOTE RA
290A4067B
BLK
WHT
GRN
11
12
MASTER SPEAKER
5
4
GRN 1
WHT 2
CONTROL
SLAVE
1
200 FT. MAX.
2
AUDIO
MASTER
SPEAKER
1K
1WATT
SEE POWER
* CONNECTIONS
*
COMMON
RED
BLK
GRN
WHT
BLK
WHT
290A4068
OPERATING PRINCIPLE:
1. Master station is both a speaker and a microphone.
2. Master is normally in Listen mode until the PTT (press-to-talk) switch is pressed to
talk to slave.
3. Outgoing and incoming volumes are controlled by separate controls on slave.
4. Slave talks to master hands-free, without having to press a talk switch.
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker volume control
3. Outgoing Volume Control
4. Speaker Model AD-SS-25 with swivel mounting
bracket or Speaker Model AD-SF-25 with holes
in outer flange for flush mounting
5. PTT (press-to-talk) switchcustomer supplied
-18-
POWER CONNECTIONS:
BLK
+DC Power
12/24V Models
WHT Common
12/24V Models
POWER
12-18VDC
SLAVE
AD-26D-8-M44
-19-
AUDIO
LINE
BLK
WHT
GRN
* CONNECTIONS
SEE POWER
REMOTE "A"
GRN
RED
WHT
BLK
AUDIO CABLE
1
WATT
1K
BLK
WHT
GRN
REMOTE "B"
WHT
BLK
TO OTHER
INTERCOMS
AUDIO CABLE
AUXILLIARY
SIGNALING DEVICE
- POWER
290A4069
+ POWER
AD-26-3
AD-27-3
AD-56-3
AD-57-3
12-18VDC
120V 50/60Hz
22-30VDC
240V 50/60Hz
POWER CONNECTIONS:
BLK
+DC Power
HOT
WHT
Common
Neutral
GRN
Earth Ground
Remote A
Power
12/24V Models
120/240V Models
12/24V Models
120/240V Models
120/240V Models only
AD-26
AD-27
AD-56
AD-57
Remote B
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Listen/Talk Switch
4. Call Switch
5. Customer-Supplied Auxiliary Signaling Device (e.g., strobe
light)
Operating Principle:
When one talks, all intercoms will hear.
To talk to other stations, press the talk/listen switch and
speak into the speaker/microphone. Release talk switch to
listen.
Pressing the call button on remote A provides a contact
closure for an attention-getting auxiliary signaling device,
e.g. a strobe light.
13
-20-
BLK
WHT
GRN
SEE POWER
CONNECTIONS
MASTER
BLK
RED
CONTROL
(+) POWER
BLK
RED
GRN
WHT
AUDIO
COMMON
1K
GRN
1
WATT
WHT
REMOTE
290A4070
AD-27C-1-M22
Master
Remote
AD-26-1-2
POWER CONNECTIONS:
BLK
HOT
120/240V Models
WHT
Neutral
120/240V Models
GRN
Earth Ground 120/240V Models
Power
Not applicable
120V 50/60Hz
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Press-To-Talk Switch
4. Master Monitor Switch
Operating Principle:
Master presses talk switch to talk to remote.
Master can turn monitor switch on and hear
everything going on at remote.
When master monitor switch is off, remote must
press talk switch to talk to master.
When master monitor switch is on, remote can talk
to master hands-free without pressing the talk
switch.
Master supplies power to remote unit.
14
-21-
BLK
WHT
GRN
SEE POWER
* CONNECTIONS
MASTER
BLK
CONTROL
BLK
GRN
WHT
BLK
WHT
GRN
COMMON
WHT
1K
AUDIO
1
WATT
GRN
SLAVE
290A4071
Master
AD-27C-M22
Slave
AD-27-2W3
POWER CONNECTIONS:
BLK
HOT
120/240V Models
WHT
Neutral
120/240V Models
GRN
Earth Ground
120/240V Models
Power
120V 50/60Hz
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Press-To-Talk Switch
4. Monitor On/Off Switch
Operating Principle:
Master presses talk switch to talk to slave.
Master can turn monitor switch on and hear
everything going on at slave.
When master monitor switch is off, slave must
press talk switch to talk to master.
When master monitor switch is on, slave can talk
to master hands-free without pressing the talk
switch.
15
RED
BLK
GRN
WHT
SPKR
HEADSET
-22BLK
COMMON
BLK
WHT
12/24V Models
12/24V Models
Master B
AD-26C-1-M34
WHT
RED
GRN
CONTROL
Master A
AD-26C-1-M80
SLAVE
HEADSET
+ DC POWER
1WATT
1K
SPKR
RED
AUDIO
GRN
POWER CONNECTIONS:
RED
+DC Power
WHT
Common
Power
12-18VDC
MASTER "A"
SPKR
WHT
BLK
RED
GRN
HEADSET
MASTER "B"
Slave
AD-26D-1-M34
290A4072
( )
DC POWER
(+)
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Press-To-Talk Switch
4. Headset/Speaker Selector Switch
5. #137145 Headset w/noise-canceling
microphone
6. #137146 Belt switch w/15 ft. cord
7. Receptacle for headset
8. 12 ft. cord for remote customer-supplied
headset receptacle
Operating Principle:
Masters normally listen (monitor) slave.
Slave can talk to master hands-free without
having to press a talk switch.
When one station talks, other stations will
hear.
To talk to other stations, master must press a
talk switch on intercom or on belt switch.
Master and slave can select to talk/listen on
either the speaker/microphone or headset via
selector switch.
16
-23-
( )
COMMON
WHT
POWER CONNECTIONS:
BLK
+DC Power
WHT
Common
Master B
AD-26C-1-2
AD-56C-1-2
12/24V Models
12/24V Models
OR YEL
BRN
RED
1K
1WATT
WHT
BLK
CONTROL
RED
GRN
BLU
Master A
AD-26C-1
AD-56C-1
+ DC POWER
BLK
AUDIO
MASTER "B"
GRN
Power
12-18VDC
22-30VDC
POWER
(+)
MASTER "A"
AUDIO
Slave
AD-26D-1
AD-56D-1
COMMON
CONTROL
+ DC POWER
WHT
RED
BLK
GRN
SLAVE
290A4073
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Press-To-Talk Switch
4. External Press-To-Talk Switch, Momentary
(e.g., foot switch)
5. 4-conductor/16-22 gauge cable. Use
shielded cable in electrically noisy areas.
Ground one end of the shield to earth
ground. Ground chassis of DC units to
ground.
Operating Principle:
Master normally listens to slave.
Slave talks to master hands-free, without
having to press a talk switch.
When any master presses talk switch, slave
hears. Other master will also hear.
To talk into master, press talk switch and
speak into speaker/microphone. Release
talk switch to listen.
Master B can talk by pressing either the talk
switch or external switch (customer
supplied).
17
BLK
WHT
GRN
SEE POWER
* CONNECTIONS
MASTER
RA
WHT
-24RC
RB
WHT
GRN
BLK
RED
WHT
GRN
BLK
RED
WHT
GRN
BLK
BLK
GRN
RED
TO OTHER REMOTES
RED
BLK
WHT
GRN
REMOTE "B"
TO REMOTE RB
BLK
WHT
GRN
REMOTE "A"
290A4074
Master
AD-27C-1
POWER CONNECTIONS:
BLK
HOT
WHT
Neutral
GRN
Earth Ground
Power
120V 50/60Hz
120/240V Models
120/240V Models
120/240V Models
Remotes
AD-27D-M49
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Talk/Listen Switch
4. Master Selector Switch (customer supplied)
5. Double-Pole (OFF-ON) Toggle Selector Switch
Operating Principle:
Master can select to monitor any one or more remotes via
master switch box.
To talk to remote(s), master closes desired selector switch,
presses talk switch, and speaks into the speaker/microphone.
Master releases talk switch to listen.
Selected remote(s) talk to master hands-free without having
to press remote talk switch.
Remotes cannot talk to other remotes.
Remotes not selected by master cannot talk hands-free and
must press talk switch to initiate call to master.
When initiating a call to master, remote must specify its
location for master to respond.
18
-25-
BLACK
+DC POWER
CONTROL
CONTROL
+DC POWER
+DC POWER
AUDIO
AUDIO
AUDIO
AUDIO
AUDIO
AUDIO
+DC POWER
+DC POWER
CONTROL
+DC POWER
AUDIO
CONTROL
CONTROL
AUDIO
AUDIO
+DC POWER
AUDIO
CONTROL
AUDIO
MODEL NO.
AD-26-1-M34
AD-26C-M34
AD-26C-7-M82
AD-26D-1-M82
AD-26D-1-M84
AD-26SA-25
AD-27-M34
AD-27-M82
AD-27-M83
AD-27A-4-M34
AD-27A-7-M83
AD-27C-1(-4)
AD-27C-1-7(-4)
AD-27C-M34
AD-27D-1
AD-27SA-25
AD-56C-M34
AD-56C-7-M82
AD-56SA-25
AD-57-M83
AD-57A-1(-4)
AD-57A-7-M83
AD-57C-M34
AD-57SA-25
GREEN
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
EARTH GND
EARTH GND
EARTH GND
EARTH GND
EARTH GND
EARTH GND
EARTH GND
EARTH GND
EARTH GND
EARTH GND
N/A*
N/A*
N/A*
EARTH GND
EARTH GND
EARTH GND
EARTH GND
EARTH GND
19
20
3.88
5.68
.41
2 HOLES
9.88
4.84
5.00
6.50
-26-
290A3697
2561494H
REV. H Printed 11/06
Printed in U.S.A.