The design of Jarret Industrial Shock Absorber utilizes the unique compression and shear characteristics of
specially formulated silicone elastomers.
These characteristics allow the energy absorption and return spring functions to be combined into a single
unit without the need for an additional gas or mechanical spring stroke return mechanism.
Applications: Advantages:
Shock protection for all types of industries including: - Simple design - High reliability
Defense, Automobile, Railroad, Materials Handling, - High damping coefficient
Marine, Pulp/Paper, Metal Producing and Processing. - Low sensitivity to temperature variances
93 www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 94
Jarret Series JT
BC1N, BC5, LR Series
Visco-elastic Technology
Visco-elastic Technology
Reservoir
Visco-elastic
Fluid
Impact Plate
Piston
External Guide
Sweeper
Mounting
Flange
Piston
Retainer
Visco-elastic technology makes use of the fundamental properties of specially formulated Jarret visco-elastic fluids.
Compressibility:
Preloaded spring function
- F = F0 + KX
Viscosity:
Shock absorber function
- F = F0 + KX + CV α with α
between 0,1 and 0,4
The two functions can be used separately or in combination, in the same product:
www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29 94
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 95
L1 L1
L2 Stroke L2 Stroke
L4
BC1N Series
L3
L6
4 Holes D7
D5
D1
D6
D4
D1
D3
L5
Rear flange mounting - Fa Threaded body mounting - Fc
Rdymax
Return Force
Return Force
Max Max
Energy Reaction
Catalog No./ Capacity Stroke Extension Compression Rdy0 Force
Model kJ mm kN kN kN kN
BC1ZN 0,1 12 0,94 5,4 6 11
BC1BN 0,43 22 2,5 14,0 14 27
BC1DN 1,5 35 5,2 28,8 28 60
BC1EN 3,4 45 7,8 43,0 45 100
BC1FN 7 60 13,6 76,6 90 150
BC1GN 14 80 19,0 130,0 130 230
95 www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 96
BC1N Series
C
6 - Application Example
Given data: Effective mass = 15 t,
Effective speed = 0,8 m/s
Impact frequency: 25 impacts/hour
1: BC1FN Selected
Force kN 4,8
Ce = 60 7 (0,03 x 0,8 + 0,24) +1,36 - 1,17
Rdymax
5: With an Rdye = [(150 - 90) x 49/60) + 90)] x (0,1 x
Rdy0 0,8 + 0,8) = 122 kN
E= 1 Me Ve2
2
En
F < 20 x Impacts/hour
E
4 - Effective Stroke Calculation
Ce = C E +1,36 - 1,17
En (0,03 V + 0,24)
www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29 96
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 97
4 holes ø D5 ø D2 L5 L6
ø D2
ø D1
ø D3
ø D4
L8
L7 L5 L4 Front Flange Mount - Fc
L3
97 www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 98
BC5 Series
Surface protection : Electrolytic zinc C
Dynamic performance diagram
Force kN 5 - Application Example
Rdymax Data: Two shock absorbers in series, Effective mass
m =300 t, Impact speed v = 1,2 m/s (which is an impact
of 0,6 m/s on each shock absorber), Impact frequency = 15
Rdy0 impacts/hour, Maximum allowable structural load 1000 kN
1 1
1: E = ( mV2) - Selection BC5-E
2 2
Stroke mm 150
2: Maximum allowable impact frequency is 15 x
Symbols: 108
21 impacts/hour. Therefore 15 impacts/hour
En = Energy Capacity
is acceptable.
C = Maximum Stroke
Rdy = Dynamic Reaction
3: Required stroke is 167 mm
1 - Energy Calculation 108
Ce = 180 x +1,36 - 1,17 = 156 mm
150 (0,03 x 0,6 + 0,24)
E= 1 Me Ve2
2
156
4: Rdye = ( 1 100 - 640) x + 640 ( 0,1x 0,6 + 0,8 )
2 - Allowable Impact Frequency 180
En
F < 15 x Impacts/hour
E = 893 kN < 1000 kN, maximum allowable impact frequency
www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29 98
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 99
L7
L8
ø D1
ø D1
ø D3
ø D4
LR Series
L5 L6
L4 Stroke 4 holes ø D5
L2 L3
L1
XLR Series - Front Flange Mount- Fc
99 www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 100
LR Series
Dynamic performance diagram
1: XLR100-400 selected
Stroke mm
Symbols: 2: Energy dissipated/impact is 72,6 kJ
En = Energy Capacity
C = Maximum Stroke 3: Maximum allowable impact frequency
Rdy = Dynamic Reaction 8 x 100 / 72,6 = 11 (Therefore 8 impacts/hr is acceptable)
1
E = Me Ve2 72,6
2 Ce = 400 x + 1,83 - 1,35
100 (0,027 x 2,2 + 0,22)
2 - Allowable Impact Frequency
Ce = 301,8mm
En
F<8x Impacts/hour
E
5: Rdye = 284,4 (0,1 x 2,2 + 0,8) = 290,1 kN
3 - Required Stroke Calculation
www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29 100
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 101
L7
L8
ø D1
ø D3
ø D4
LR Series
L5 L6
4 holes ø D5 L4 Stroke
L2 L3
L1
101 www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29
A4-Metric:Project1-A4-Metric 2/13/08 9:03 AM Page 102
LR Series
Dynamic performance diagram
1: BCLR400 selected
Stroke mm
Symbols: 2: Energy dissipated/impact is 274 kJ
En = Energy Capacity
C = Maximum Stroke 3: Maximum allowable impact frequency
Rdy = Dynamic Reaction 8 x 400 / 274 = 12 (Therefore 8 impacts/hr is acceptable)
1
E = Me Ve2 274
2 Ce = 850 x + 1,83 - 1,35
400 (0,027 x 2,7 + 0,22)
2 - Allowable Impact Frequency
Ce = 587mm
En
F<8x Impacts/hour
E
5: Rdye = 520 (0,1 x 2,7 + 0,8) = 556 kN
3 - Required Stroke Calculation
www.enidine.eu Email: info@enidine.eu Tel.: +49 7621 98679-0 Fax: +49 7621 98679-29 102