Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

VentSilencerBrochure Imperial

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9
At a glance
Powered by AI
The document discusses IAC Acoustics, a company that manufactures vent silencers to reduce noise from industrial processes like power plants and oil and gas facilities.

Vent silencers are used to reduce very high noise levels created when high pressure gas or steam is rapidly expanded to the atmosphere through safety valves, relief valves, and other industrial valves and vessels.

The two main noise reduction principles used in vent silencers are a reactive section (diffuser) to attenuate low frequencies and a sound absorbing material to absorb high frequency noise.

Vent Silencers

A complete range of products


for high pressure systems

IAC Acoustics
Making the World a Quieter Place
Founded on an unrivalled history of engineering with some
of the most pioneering discoveries in the industry, the IAC Acoustics
brand is synonymous with technological innovation.
From controlling noise at a power station to tuning the sound
in a TV or radio studio, IAC Acoustics has had a positive impact
on society and helped to shape what can be achieved to make speech
more intelligible, music more enjoyable, reduce the impact
of industrial noise and protect peoples sense of hearing.

Page
4

Vent Silencer overview

Vent Silencer specifications

Vent Silencer standard range

Selection tool

10

Standard dimentions

11

Options

12

Our customers

14

Office contacts

The continual success of our products and services over the decades
has brought the brand a reputation for quality and reliability among
customers, whether they are multinational corporations or independent
family businesses. This is supported by the expertise and passion of our
workforce, the people behind the products, including designers, engineers
and industry specialists.
To face the ever increasing noise reduction demands of the future,
we will strive to further enhance our ability to reduce excessive noise.
We aim to focus on developing tomorrows solution today, innovating
faster and delivering solutions that meet the requirements of the next
generation. In doing so, we will stay true to our key values and founding
philosophy to make the world a quieter place.

Vent Silencer Overview


A vent silencer is a device intended to reduce the very high noise levels created
when high pressure gas or steam is expanded to the atmosphere.
This noise is produced by rapid turbulence of the vented gas jet and the release
of energy from the compressed gas. Most of the noise occurs at the expansion
across the valve and is emitted at the stack opening.
The vent silencer can also provide back pressure relief for the system ensuring
proper operation.
There are two noise reduction principles used in a vent silencer.
The first is a reactive section (diffuser) to attenuate the low frequencies and
provide broad band noise reduction.
The second principle is absorption of the high frequency audible noise
into a sound absorbing material.
Typical Applications
Safety valve (PSV)
Relief valve (PRV)
Ejector
Start up valve
Snort-valve
Flash and blow down tanks

Typical Installations Include:


Combined cycle
CHP plants
Fossil fuel power plants
Thermal solar plants
Nuclear power stations
Industrial applications
Oil and gas applications

Our Capabilities




Acoustical design and optimization


3D CAD model engineering
Static calculation
Pressure part calculation
Pressure part design check

Pressure Equipment Directive


(PED) compliance
Quality inspection
Full technical documentation
Full supply-chain service

Vent Silencer
Specifications
Hydraulic Sizing
Flow rate, valve set pressure
and temperature
Saturated or superheated steam
Other gases: including oxygen and methane.
Type of Operation
Safety: intermittent operation
Control, start-up and blow down: regular or
continuous operation
Pressure Drop / Back Pressure
Valve integrity factor
Control and stabilization of process condition
Material Specification
From low temperature to high temperature
Corrosion allowance
Noise Guarantee Details
Point of measure
Pipe noise interference
Pipe Connection
Butt weld
Flanges
Counters flanges / seals / bolts
Rain Hoods
Impact on noise guarantee depending on
measure point
Snow and ice issue
PED
Applicable within the EEC and elsewhere
whenever the customer requires it
For silencer with diffuser tubes and pressure
drop (1st stage) above 0.5 bar g
Mechanical withstand guarantee: NDT, PMI,
CE Marking
6

Vent Silencer Standard Range

Selection
Tool
All IAC Acoustics standard vent silencers can be
configured online using our selection tool

Noise Reduction
dB(A)
Special

Residual
noise
level

Available for higher noise reduction

Super Extreme

From 0 to 90 lb/s [40 kg/s]

Extreme

From 0 to 90 lb/s [40 kg/s]

Super Critical

From 0 to 90 lb/s [40 kg/s]

Critical

From 0 to 150 lb/s [70 kg/s]

Residential

From 0 to 150 lb/s [70 kg/s]

Inlet
Mass flow
connection
rate
Fluid
description

60

50

Selection
tool

40

30

20
Contact IAC Acoustics to
receive your unique username
and password, then visit:
http://vent.iac-acoustics.com

Vent Silencer Dimensions


Length (inches)
Outer
Residential
Diameter

Critical

Super
Critical

Vent Silencer Options

Weight (lb)
Extreme Residential

Critical

Super
Critical

Extreme

13

20

20

20

24

104

108

112

128

19

30

30

30

36

236

243

265

302

25

40

40

40

48

408

419

465

534

31

50

50

50

60

626

644

723

833

35

55

55

55

67

800

822

922

1063

37

60

60

60

72

928

955

1074

1237

41

65

65

65

78

1091

1124

1268

1462

44

70

70

70

84

1250

1285

1451

1678

47

75

75

75

90

1429

1470

1664

1925

50

80

80

80

96

1636

1682

1951

2258

54

86

86

86

103

2101

2163

2474

2873

57

92

92

92

110

2573

2646

3007

3479

61

98

98

98

118

2950

3034

3450

3995

66

105

105

105

126

3382

3481

4030

4667

70

113

113

113

135

3882

3993

4914

5741

75

121

121

121

145

4456

4583

5655

6616

81

129

129

129

155

5117

5265

6557

7670

87

139

139

139

166

5878

6047

7553

8847

93

148

148

148

178

8164

8397

10152

11949

Above figures are given as information only

VS

(Standard supply: Butt weld)


Connecting flanges
Standard: WN flanges Class 150# as per
ASME B 16.5
Options available for other classes and
alternatives (e.g. slip-on)

Support
Standard supports are part of the bottom plate
and other supports can be supplied as options

Stuffing Box
Allows pipe movements due to thermal
expansion, avoiding nozzle loads
Standard radial movement is +/- 20mm
Standard axial movement up to 50mm
Pipe sealing is maintained

Product Referencing
3

Connection

RE

1030

CS

080

CR

Rain Hoods

SC

Prevents rain entering the silencer


Bottom drain as standard

EX
Product
Group

Family
Vent Silencer

SE

Measurement
Unit
Metric
Imperial

Silencer
Diameter

Material
Carbon Steel

Inlet Pipe
Diameter
( 10 x inches )

Acoustic
Performance
10

11

Our Customers
IAC Acoustics has provided vent silencers to some of the largest
organizations around the world.
Some of of past clients include:
Air Liquide
Thermax
Jacobs
Boccard
Cegelec
Cevital SPA
CME Engineering
Cockerill Mechanical Industries
Diamond Power
APA Gasnet
Foster Wheeler
EDF
Dresser
Exxon
Technip
Chiyoda
Total
JGV
Aramco
Reliance
ESB
COFIVA
QatarGaz
SNC-Lavalin
CTEP
CNIM
Alstom
PraxAir

12

13

Contacts
Head Office - Winchester, UK
T: +44 (0) 1962 873 000
F: +44 (0) 1962 873 111
E: winchester@iac-acoustics.com

UAE - Dubai
T: +971 42 517 456
F: +971 42 517 457
E: dubai@iac-acoustics.com

Australia
T: +61 (0) 2 8781 0400
F: +61 (0) 2 9725 2939
E: australia@iac-acoustics.com

USA - Houston
T: +1 (832) 554 0980
F: +1 (832) 554 0990
E: houston@iac-acoustics.com

Canada
T: +1 (905) 612 4000
F: +1 (905) 612 8999
E: toronto@iac-acoustics.com

USA - Lincoln
T: +1 (402) 323 7272
F: +1 (402) 323 7271
E: lincoln@iac-acoustics.com

China
T: +86 (0) 769 89899966 802
F: +86 (0) 769 89899966 810
E: china@iac-acoustics.com

USA - New York


T: +1 (718) 931 8000
F: +1 (718) 863 1138
E: newyork@iac-acoustics.com

Denmark
T: +45 36 77 88 00
F: +45 36 78 12 30
E: nordic@iac-acoustics.com
France
T: +33 (0) 3 20 05 88 88
F: +33 (0) 3 20 05 88 99
E: france@iac-acoustics.com
Germany
T: +49 (0) 2163 9991 0
F: +49 (0) 2163 9991 23
E: deutschland@iac-acoustics.com
Italy
T: +39 02 48 44 22 1
F: +39 02 48 44 22 22
E: italia@iac-acoustics.com
Spain
T: +34 93 321 6684
F: +34 93 321 6249
E: espana@iac-acoustics.com

Making the world a quieter place

3VS Imperial Rev 1.1 11_2013

www.iac-acoustics.com

You might also like