CMP PRODUCTS
PERTH, WA
CMP PRODUCTS
Street Address :
CMP Products Pty Ltd
Unit 2-3/22 Harlond Avenue, Malaga, WA 6090
Postal Address :
CMP Products Pty Ltd
PO Box 1994, Malaga, WA 6944
Tel: +61 8 9249 4508
Fax: +61 8 9249 4608
E-Mail: perthoffice@cmp-products.com
Cable Glands approved for Group I mining applications are also available from CMP Products
for a wide variety of cable types.
Distributor :
Ex d / Ex e / Ex nR
Document Reference : TPC168 ISSUE 3 04/12
CONTENTS
RAPID Ex
10
11
www.cmp-products.com
12
13
14
15
TECHNICAL DATA
II 2/3 GD, Ex d IIC, Ex e II,
(e.g. CY / SY), Single Wire Armour (SWA), Aluminium Wire Armour (AWA),
Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire Braid Armour
(e.g. SWB), Armored & Jacketed
CMP Triton CDS Type T3CDS/PB Triple Certified Flameproof (Type 'd'),
Increased Safety (Type 'e') and Restricted Breathing (Type nR) indoor
and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone
22 Hazardous Areas with all types of lead sheathed / lead covered
and armoured cable providing a flameproof seal on the cable inner
lead covering and an environmental seal on the cable outer sheath.
This product utilises a unique Compensating Displacement Seal (CDS)
system which provides full compatibility with restricted breathing
equipment that rely upon flammable gases being excluded from the
main enclosure. The cable gland being suitable for use with armoured
cables, provides mechanical cable retention and electrical continuity
via armour wire termination and earth bonding of the lead sheath. A reversible armour cone and AnyWay universal
clamping ring arrangement allows the cable to be easily disconnected from the equipment, for maintenance and
change out etc, and re-connected with the same consummate ease. This feature also facilitates remote make off
procedures when the termination is to be conducted in confined spaces or in areas of restricted access. Separate
tightening actions for the inner compensating displacement seal (CDS) system and the armour termination affords
maximum control over the pressure applied to the cable inner lead covering.
All CMP Cable Glands are EMC tested.
THREAD SEALS
The CMP Triton CDS Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1,
Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection, installation and
maintenance is observed, e.g. IEC 60079-14.
SELECTION INFORMATION
16
APPROVAL DETAIL
ATEX : SIRA06ATEX1283X, SIRA07ATEX4328X
ATEX Code of Protection Category :
ORDERING INFORMATION
CABLE GLAND SELECTION CHARTS
The CMP Triton CDS Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1,
Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection, installation and
maintenance is observed, e.g. IEC 60079-14.
APPROVAL DETAIL
17
TECHNICAL DATA
II 2/3 GD, Ex d IIC, Ex e II,
& Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour
(LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed &
Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA)
SEALING AREA(S) : Cable Inner Lead Covering & Cable Outer Sheath
1
1
E1FW TRI-STAR
E1FX TRI-STAR
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type d), Increased
Safety (Type e) and Restricted Breathing (Type nR) cable gland for use
in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single
Wire Armour (SWA) cable.
This cable gland provides a flameproof seal on the cable inner bedding
and in addition the gas tight seal has been tested to prove compatibility
with Restricted Breathing equipment.
The cable gland allows mechanical cable retention and earth continuity via
the cable armour termination. Separate tightening actions for the inner
displacement seal and the armour termination afford maximum control over the pressure applied to the cable bedding, and
also allows the effectiveness of the gas tight seal to be tested.
A detachable armour cone and AnyWay clamping ring arrangement facilitates remote make off and enables the cable to be
disconnected from the equipment.An environmental / load retention seal is provided on the cable outer sheath.
Separate tightening actions for the inner displacement seal and the armour termination afford maximum
control over the pressure applied to cable bedding, and also allows the effectiveness of the gas tight seal to
be tested. A detachable armour cone and AnyWay clamping ring arrangement facilitates remote make off
and enables the cable to be disconnected from the equipment. An environmental / load retention seal is
provided on the cable outer sheath.
The CMP E1FW Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2,
Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g.
IEC 60079-14
The CMP E1FX Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in
Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and
installation is observed, e.g. IEC 60079-14.
APPROVAL DETAIL
TECHNICAL DATA
APPROVAL DETAIL
I M2 Ex dI, Ex e I
(PWA), Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip
Armour (ASA), Armored & Jacketed
E2FX TRI-STAR
This cable gland provides a flameproof seal on the cable inner lead
covering and in addition the gas tight seal has been tested to prove
compatibility with Restricted Breathing equipment that relies upon
flammable gases being excluded from the main enclosure. The cable gland
allows mechanical cable retention and earth continuity via the cable
armour termination, and also earth bonding of the inner lead covering or
lead sheath. Separate tightening actions for the inner displacement seal and the armour termination afford maximum control
over the pressure applied to the cable inner lead covering, and also allows the effectiveness of the gas tight seal to be tested.
A detachable armour cone and AnyWay clamping ring arrangement facilitates remote make off and enables the cable to be
disconnected from the equipment. An environmental / load retention seal is provided on the cable outer sheath.
All CMP Cable Glands are EMC tested.
The CMP E2FW Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2,
Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed,
e.g. IEC 60079-14.
APPROVAL DETAIL
TECHNICAL DATA
CMP Type E2FW Tri-Star Triple Certified Flameproof (Type d), Increased
Safety (Type e) and Restricted Breathing (Type nR) cable gland for use
in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with lead
covered or lead sheathed and single wire armour (SWA) cable.
E2FW TRI-STAR
TECHNICAL DATA
APPROVAL DETAIL
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Code of Protection Category :
TECHNICAL DATA
II 2/3 GD, Ex d IIC, Ex e II,
www.cmp-products.com
www.cmp-products.com
E1FU TRI-STAR
PX2K
CMP Type PX2K Triple Certified Flameproof (Type d), Increased Safety
(Type e) and Restricted Breathing (Type nR) cable gland for use in Zone
1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of
armoured cable providing a compound barrier seal around the cable
conductors and an environmental seal on the cable outer sheath. The
cable gland provides mechanical cable retention and electrical continuity
via armour termination.
A combined detachable armour cone and compound tube, together with
AnyWay universal clamping ring arrangement allows the cable to be
easily disconnected from the equipment, for maintenance and change out
etc, and re connected with the same consummate ease. This feature also facilitates remote make off procedures when the
termination is to be conducted in confined spaces or in areas of restricted access.
All CMP Cable Glands are EMC Tested.
The CMP PX2K cable gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 &
Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
The PX2K is supplied in kit form inclusive of two detachable armour cones. Stepped Cone is suitable for SWA cables,
Grooved Cone is suitable for all other approved armoured cables. PX2K/PB for use with lead sheathed/lead covered cables.
APPROVAL DETAIL
TECHNICAL DATA
APPROVAL DETAIL
Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip Armour
(ASA), Pliable Wire Armour (PWA), Screened Flexible Wire Braid (e.g. CY / SY),
I M2 Ex dI, Ex e I
E2FU TRI-STAR
Separate tightening actions for the inner Displacement Seal and the Armour Termination afford maximum
control over the pressure applied to the cable inner lead covering, and also allows the effectiveness of the gas
tight seal to be tested. A detachable universal armour cone and AnyWay clamping ring arrangement
facilitates remote make off and enables the cable to be disconnected from the equipment. An environmental /
load retention seal is provided on the cable outer sheath.
The CMP E2FU Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in
Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and
installation is observed, e.g. IEC 60079-14.
TECHNICAL DATA
Ex II 2/3 GD, Ex d IIC,
IM2 Ex d, Exe I
PXSS2K
APPROVAL DETAIL
TECHNICAL DATA
APPROVAL DETAIL
TECHNICAL DATA
& Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour
(LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed &
Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA)
SEALING AREA(S): Cable Inner Lead Covering & Cable Outer Sheath
www.cmp-products.com
www.cmp-products.com
PX2K-REX
RapidEx is the revolutionary method for installing barrier glands. The gland
utilises a liquid pour resin seal, that vastly reduces installation time and
associated costs. This solution is particularly effective on multicore cables
where traditional compound is difficult and time consuming to apply.
RapidEx benefits
is a revolutionary sealing system that gets
right to the heart of the cable interstices and
can be reliably installed in no time at all.
APPROVAL DETAIL
TECHNICAL DATA
Wire Braid Armour (e.g. SWB), Screened Flexible Wire Braid (e.g. CY / SY),
Pliable Wire Armour (PWA), Steel Tape Armour (STA), Strip Armour (e.g. ASA)
PXSS2K-REX
In the process of curing the RapidEx resin adheres to both the cable
conductors and the inside of the barrier tube creating a bond that is set for
the life of the cable gland product. The RapidEx seal will never crack or
shrink with changes in temperature.
Ease of application
During application the liquid resin flows between and around the cable
conductors ensuring a complete and total seal with zero gaps.
Faster curing
RapidEx liquid pour resin cures approximately 15 times faster than
traditional clay based compound. RapidEX cures in 15 minutes at 40C,
and 30 minutes at 20C.
APPROVAL DETAIL
TECHNICAL DATA
Enhanced reliability
www.cmp-products.com
www.cmp-products.com
A2F
The CMP A2F Tri-Star Cable Gland is suitable for use with all forms of equipment
protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection,
installation and maintenance is observed, e.g. IEC 60079-14.
APPROVAL DETAIL
TECHNICAL DATA
V-TEC EX
These Cable Gland products provide an environmental seal on the cable outer
sheath and have been introduced as a cost effective solution for all indoor and
outdoor cable installations in Zone 1 and Zone 2 Hazardous Areas, where Ex e or EEx e Code of Protection has been
permitted. This cable gland is also suitable for use in conjunction with Ex de or EEx de equipment and apparatus which has an
increased safety terminal chamber.EC design type approval certificate number : PTB 99 ATEX 3112X and 3113X.
EC design type approval certificate number :
PTB 99 ATEX 3112X and 3113X.
APPROVAL DETAIL
TECHNICAL DATA
APPROVAL DETAIL
TECHNICAL DATA
C2K
TECHNICAL DATA
CMP Type A2F Triple Certified Flameproof (Type 'd'), Increased Safety (Type 'e')
and Restricted Breathing (Type nR) indoor and outdoor cable gland for use in
Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured and
braided cable providing a combined flameproof seal and environmental seal on
the cable outer sheath. This product provides full compatibility with restricted
breathing equipment that rely upon flammable gases being excluded from the main
enclosure.
APPROVAL DETAIL
This product provides full compatibility with Restricted Breathing equipment and affords extra stability and superior resistance
to cable pull out. The CMP SS2K Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in
Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is
observed, e.g. IEC 60079-14. SS2k/PB for use with lead sheathed/lead covered cables & SS2K/TA for use with steel tape
armour also available.
The CMP A2F Tri-Star Cable Gland is suitable for use with all forms of equipment
protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection,
installation and maintenance is observed, e.g. IEC 60079-14.
V
D
CMP Type SS2K Tri-Star Triple Certified Flameproof (Type 'd'), Increased Safety
(Type 'e') and Restricted Breathing (Type nR) indoor and outdoor cable gland for
use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured
cables. This cable gland provides a flameproof seal on the cable inner sheath (or
outer sheath of single sheathed cable) and a secondary environmental seal
on the cable outer sheath. This cable gland can also be used with braided cables
where the sealing is made on the cable overall diameter, when this arrangement is
permitted by the prevailing installation code of practice, and the metallic braid is
earthed inside the equipment.
The CMP A2FRC Tri-Star Cable Gland is suitable for use with all forms of
equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice
for selection and installation is observed, e.g. IEC 60079-14.
SS2K
CMP Type A2FRC Tri-Star Triple Certified Flameproof (Type 'd'), Increased Safety
(Type 'e') and Restricted Breathing (Type nR) indoor and outdoor conduit
connection cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22
hazardous areas with un-armoured cable housed in rigid or flexible conduit
systems. The cable gland provides a combined flameproof seal and environmental
seal on the cable outer sheath. This product provides full compatibility with
restricted breathing equipment.
The CMP C2K Cable Gland is suitable for use with Increased Safety Type e and Flameproof Type d enclosures that are
equipped with a secondary Increased Safety Type e terminal enclosure (i.e. Ex de) provided always that no source of ignition
prevails and the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
APPROVAL DETAIL
TECHNICAL DATA
www.cmp-products.com
www.cmp-products.com
CWE
The CMP CWe Cable Gland is suitable for use with Increased Safety Type e and Flameproof Type d enclosures that are
equipped with a secondary Increased Safety Type e terminal enclosure (i.e. Ex de) provided always that no source of ignition
prevails and the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
APPROVAL DETAIL
TECHNICAL DATA
CXe
The CMP CXe Cable Gland is suitable for use with Increased Safety Type e and Flameproof Type d enclosures that are
equipped with a secondary Increased Safety Type e terminal enclosure (i.e. Ex de) provided always that no source of ignition
prevails and the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
APPROVAL DETAIL
TECHNICAL DATA
C2KX
RapidEx is the revolutionary method for installing barrier glands. The gland utilises a
liquid pour resin seal, that vastly reduces installation time and associated costs. This
solution is particularly effective on multicore cables where traditional compound is difficult
and time consuming to apply.
CMP Type PX2KX-REX Triple Certified Flameproof (Type d), Increased Safety (Type e)
and Restricted Breathing (Type nR) cable gland for use in Zone 1, Zone 2, Zone 21 and
Zone 22 Hazardous Areas with all types of braid cable providing a RapidEx barrier seal
around the cable conductors and an environmental seal on the cable outer sheath.
All CMP Cable Connectors are EMC Tested.The cable gland provides mechanical cable
retention and electrical continuity via armour termination. A combined detachable armour cone and resin tube, together with AnyWay universal
clamping ring arrangement allows the cable to be easily disconnected from the equipment, for maintenance and change out etc., and re connected
with the same consummate ease. This feature also facilitates remote make off procedures when the termination is to be conducted in confined spaces
or in areas of restricted access. The CMP PX2KX-REX cable gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone
2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
APPROVAL DETAIL
This product provides Nema 4X and IP68 ingress protection and is UL listed for use in Class I Zone 1 AEx e II
applications and can be used in Class I Division 2 areas when installed in compliance with the NEC requirements.
10
APPROVAL DETAIL
TECHNICAL DATA
ATEX : SIRA06ATEX1097X
ATEX Code of Protection Category :
II 2 GD, Ex e II, Ex tD A21 IP66
IECEx : IECEx SIR 06.0041X
Ingress Protection : IP66, IP67, IP68
Additional Approvals Held : CSA, GOST R (POCC GB. 06.B00207), GOST K
(KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
TECHNICAL DATA
IM2 Ex d I, Ex e I
Ex nR II, Ex tD A21 IP66:
IECEx : IECEx SIR 06.0044X
Ingress Protection : IP66, IP67, IP68
Additional Approvals Held : GOST R (POCC GB.HO06.B00207),
INMETRO, ABS, DNV, LLOYDS, NEPSI, cCSAus
TMC2
All CMP Cable Connectors are EMC Tested. The 2-part design allows the grounding and over
jacket sealing to be actioned in a single simple movement and allows he cable to be easily
removed from the equipment, for maintenance and change out etc. The TMC2 cable connector is supplied in Copper free (<0.4%), Aluminium,
Stainless Steel, or Electroless Nickel Plated Brass in NPT (standard) and Metric thread forms.
APPROVAL DETAIL
ATEX : SIRA09ATEX1164X
ATEX Code of Protection Category :
II 2 GD, Ex d IIC Gb, Ex e IIC Gb,
Ex ta IIIC Da
IECEx : IECEx SIR 09.0068X
Additional Approvals Held : cCSAus, GOST R (POCC GB.HO06.B00207),
GOST K (KZ 75000361 01 01 14761), ABS, DNV
TMC2X
TECHNICAL DATA
TEMPERATURE RATING : -60C TO +110C
CABLE TYPE : Corrugated & Interlocked Metal Clad Armor
(MC) or TECK, Continuously Welded Metal Clad Armor (MCHL)
SEALING AREA (S) : Cable Outer Jacket
CMP C2KX Cable Connector suitable for use with Armored & Jacketed
cables incorporating Wire Braid Armor in Ordinary, Wet & Hazardous
Locations.
The cable connector provides mechanical retention and electrical
continuity via the armor termination and is available in NPT (standard) or
Metric thread forms. Standard material is Brass grade CuZn39Pb3
(CW614N) to EN12168 with Electroless Nickel Plated Brass entry
component.
PX2KX-REX
*
*
*
*
*
All CMP Cable Connectors are EMC Tested. The TMC2X utilizes CMPs innovative RAPID Ex Fast
Curing Liquid Compound Injection System, which installs in seconds, significantly reducing
installation error, with a complete 100% cure time of 1 hour, which significantly reduces installation
times. The new 2-part design allows the grounding and over jacket sealing to be actioned in a single simple movement and allows the cable to be
easily removed from the equipment, for maintenance and change out etc. The TMC2X cable connector is supplied in Copper Free (<0.4%) Aluminium,
Stainless Steel, or Electroless Nickel Plated Brass in NPT (standard) and Metric thread forms.
APPROVAL DETAIL
ATEX : SIRA09ATEX1165X
ATEX Code of Protection Category :
II 2 GD, Ex d IIC, Ex e IIC Gb,
Ex ta IIIC Da
IECEx : IECEx SIR 09.0069X
Additional Approvals Held : cCSAus, GOST R (POCC GB.HO06.B00207),
GOST K (KZ 75000361 01 01 14761), ABS, DNV, LLOYDS
TECHNICAL DATA
11
www.cmp-products.com
www.cmp-products.com
BW
BW Cable Gland
E2U
CMP E2U type brass indoor & outdoor cable gland for use with all types of Lead Sheathed
and Armoured cables providing an environmental seal on the inner lead sheath and on the
cable outer sheath. The cable gland provides mechanical cable retention and electrical
continuity via the armour termination and also earth bonding of the inner lead covering or
lead sheath.
CMP BW type brass indoor cable gland for use with all types of Single Wire Armour (SWA)
cable providing mechanical cable retention and electrical continuity via armour wire
termination.
CMP BWL type is also available, this design benefits from a longer body to protect the
armour wires from impact.
CX
CX Cable Gland
E1W
CMP CX type brass indoor & outdoor cable gland for use with all types of Wire Braid
Armour, Strip Armour, Pliable Wire Armour & Steel Tape Armour (STA) cable providing an
environmental seal on the cable outer sheath.
CW Cable Gland
E2W
MP CW type brass indoor & outdoor cable gland for use with all types of Single Wire
Armour (SWA) cable providing an environmental seal on the cable outer sheath.
A2 Cable Gland
E1X
CMP A2 type brass indoor & outdoor cable gland for use with all types of Unarmoured
cable, providing mechanical cable retention and an environmental seal on the cable outer
sheath.
SS2KGP
E2X
A2DG
CMP SS2KGP/PB type brass indoor & outdoor cable gland for use with all types of Lead
Sheathed Unarmoured cable, providing mechanical cable retention and an environmental
seal on the cables inner lead sheath and cable outer sheath.
The cable gland also provides earth bonding of the inner lead covering or lead sheath.
E1U
Suitable for applications where superior cable pull out resistance is required.
Unarmoured cable, providing mechanical cable retention and an environmental seal on the
cables inner and outer sheath, or a double seal on the cable outer sheath.
SS2KGP/PB
The cable gland also provides mechanical cable retention and electrical continuity via
armour wire termination.
A2
The cable gland also provides mechanical cable retention and electrical continuity via
armour wire termination.
CW
A2 200
12
13
www.cmp-products.com
www.cmp-products.com
TYPE 737
TYPE 780
The CMP Type 780 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated
cable glands, to any fixed equipment. The 780 Union provides a running connection by means of an integral
coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct
termination. The ease of installation offered by the 780 Union consequently makes the process of removing the
conduit or other terminated cable entry device from the equipment a simple, fast and effective one.
Available in Brass, Aluminium or Steenless Steel these Unions are approved for use in conjunction with Ex d and
Ex e certified equipment and cable entry devices, and can also be supplied with thread conversion between the
forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to NPT, or
NPT to Metric. A General Purpose Industrial version is also available.
The CMP Type 737 range of Thread Conversion Adaptors & Reducers are designed
to provide flexibility and versatility in the execution of construction works when there
is a conflict between the type or size of the cable gland thread and the cable entry
hole in the equipment. These Thread Conversion Adaptors & Reducers are available
with Male to Female connection threads and can be supplied with thread conversion
between the forward and rear threads to either an increased or reduced size or a
different thread type, e.g. Metric to NPT, or NPT ro Metric.
TECHNICAL DATA
ATEX : SIRA01ATEX1284U, SIRA02ATEX1003X
ATEX Code of Protection Category:
II 2 GD, Ex d IIC, Ex e II,
IM2 Exd I Exe I
Ex tD A21 IP66,
IECEx : IECEx SIR 07.0083X
Additional Approvals Held : CSA, GOST R (POCC GB. 06.B00207),
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
TECHNICAL DATA
ATEX : SIRA10ATEX/306U
ATEX Code of Protection Category:
II 2 GD, Ex d IIC Gb
Ex e II Gb Ex ta III C Da IP6x Component, Zone 1,2,21 & 22 Gas Groups IIA, IIB, IIC
IECEx : IECEx SIR 05.004U
Additional Approvals Held : CSA, UL, GOST R (POCC GB.
06.B00207), GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
TYPE 747/757/767
Component approved Stopper Plugs designed to close unused cable entry holes in
explosion protected equipment. Versions available with and without integral O Ring
seal & in various materials. Also for industrial and safe area use.
TECHNICAL DATA
ATEX : SIRA01ATEX1284U, SIRA02ATEX1003X
ATEX Code of Protection Category:
II 2 GD, Ex d IIC, Ex e II,
Ex tD A21 IP66,
IM2 Exd I Exe I
IECEx : IECEx SIR 07.0083X
Additional Approvals Held : CSA, GOST R (POCC GB. 06.B00207),
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
TYPE 797
TECHNICAL DATA
TYPE 781
TECHNICAL DATA
ATEX : SIRA01ATEX1284U, SIRA02ATEX1003X
ATEX Code of Protection Category:
II 2 GD, Ex d IIC, Ex e II,
Ex tD A21 IP66,
IM2 Exd I Exe I
IECEx : IECEx SIR 07.0083X
Additional Approvals Held : CSA, GOST R (POCC GB. 06.B00207), GOST K
(KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
TYPE 777
ATEX : SIRA05ATEX1233U
ATEX Code of Protection Category:
II 2 GD, Ex d IIC & Ex e II,
IM2 Exd I Exe I Component, Zone 1,2,21 & 22 - Gas Groups IIA, IIB, IIC
IECEx : IECEx SIR 05.004U
Additional Approvals Held : CSA, UL, GOST R (POCC GB. 06.B00207),
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
Earth Tags
Serrated Washers
Locknuts
Brass Locknuts are the recommended items used in securing brass cable glands, unions, adaptors, reducers,
and stopper plugs to a gland plate or into equipment.
Aluminium versions are also available for use with CMP Aluminium Cable Glands to prevent the electrolytic
action of galvanic corrosion which can occur when dissimilar metals are coupled together.
Shrouds
CMP manufactures a range of push on shrouds which are used to minimise the risk of dirt or foreign substances
gathering on the Cable Gland Body, and/or point of cable to gland interface. Standard shrouds are produced
in Black PVC and PCP. CMP LSF (Blue/Grey) shrouds are available from stock.
PVC, PCP & LSF shrouds are also manufactured in alternative colours including Red and White to suit a variety
of customer requirements.
TECHNICAL DATA
ATEX : SIRA10ATEX1057U
ATEX Code of Protection Category:
II 2 GD, Ex d IIC Gb /Exe IIC Gb / Ex ta
IIIC Da Component, Zone 1,2,21 & 22 - Gas Groups IIA, IIB, IIC
IECEx : IECEx SIR 05.004U
Additional Approvals Held : CSA, GOST R (POCC GB. 06.B00207), GOST K
(KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
14
www.cmp-products.com
www.cmp-products.com
15
Selection Table Of Unarmoured Cable Glands Please replace XX in Ordering Reference with Cable Gland name i.e. A2
There are many factors to consider when selecting cable glands for industrial installations. Neglecting to pay due attention to some of these factors may cause
unnecessary anxiety at a future point in time when the equipment and cables have been delivered on site, but for example the cable glands have either been forgotten
to be ordered or it is discovered that they are the incorrect type or size at the very point when they are needed the most. Good advice would be to allocate some value
added planning and preparation time to the subject of cable gland selection so as to avoid the great inconvenience which is likely to occur at a critical point in time. In
the event that a user or contractor is in possession of a cable schedule that requires a cable gland selection and sizing process to be carried out, CMP Products would be
more than happy to assist in carrying out this process at no cost to the enquirer. Please contact CMP Products for further information on this subject.
Here is a summary of some aspects to carefully
consider when selecting cable glands.
Type
20S/16
20S
20
25S
25
32
40
50S
50
63S
63
75S
75
90
100
115
130
The table below is provided to allow the selection of alternative materials, thread
types, thread sizes and other options.
The part number is composed of the CMP Size, Type Number, and Standard Suffix.
Standard Suffix ID
Standard
Suffix ID
Type
Option
Metric
NPT
NPT
M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90
M100
M115
M130
1/2
1/2
1/2
3/4
1
1 1/4
1 1/2
2
2
2 1/2
2 1/2
3
3
4
-
3/4
3/4
3/4
1
1 1/4
1 1/2
2
2 1/2
2 1/2
3
3
3 1/2
3 1/2
-
20S/16
20S
20
25
32
40
50S
50
63S
63
75S
75
90
100
115
130
Cable
Gland
Size
HOW TO ORDER
Size
Standard
Cable
Bedding
Diameter
Minimum
Thread
Length
10.0
10.0
10.0
10.0
10.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
Min
Min
3.1
6.1
6.5
11.1
17.0
23.5
31.0
35.6
41.5
47.2
54.0
61.1
66.6
76.0
86.0
97.0
8.7
11.7
14.0
20.0
26.3
32.2
38.2
44.1
50.0
56.0
62.0
68.0
79.4
91.0
98.0
115.0
Across
Flats
Across
Corners
Nominal
Protrusion
Length
Ordering
Reference
(Brass Metric)
24.0
24.0
27.0
36.0
41.0
50.0
55.0
60.0
70.0
75.0
80.0
85.0
108.0
123.0
133.4
152.4
26.6
26.6
30.0
39.9
45.5
55.4
61.0
66.5
77.6
83.2
88.7
94.2
120.7
137.8
147.6
164.9
21.0
21.0
24.0
26.0
27.0
28.0
29.0
30.0
30.0
30.0
32.0
32.0
44.0
48.0
55.0
62.0
20S16XX1RA
20XX1RA
20XX1RA
25XX1RA
32XX1RA
40XX1RA
50SXX1RA
50XX1RA
63SXX1RA
63XX1RA
75SXX1RA
75XX1RA
90XX1RA
100XX1RA
115XX1RA
130XX1RA
Selection Table Of SWA Cable Glands Please replace XXXX in Ordering Reference with Cable Gland name i.e. E1FW
Cable
Gland
Size
On each of the main product pages in this catalogue you will find a cable gland
selection table which includes the part number, typically of a standard metric
product, for ordering purposes.
Nickel Plated
Finish
Option
Metric
NPT
NPT
M20
M20
M20
M25
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90
M100
M115
M130
1/2
1/2
1/2
3/4
3/4
1
1-1/4
1-1/2
2
2
2-1/2
2-1/2
3
3-1/2
-
3/4
3/4
3/4
1
1
1-1/4
1-1/2
2
2-1/2
2-1/2
3
3
3-1/2
3-1/2
-
Cable
Bedding
Diameter
Minimum
Thread
Length
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
Overall Cable
Diameter
Armour Range
Across
Flats
Across
Corners
Min
Max
Min
Max
Min
Max
Max
Max
3.1
6.1
6.5
11.1
11.1
17.0
22.0
29.5
35.6
40.1
47.2
52.8
59.1
66.6
76.0
86.0
97.0
8.7
11.7
14.0
20.0
20.0
26.3
32.2
38.2
44.1
50.0
56.0
62.0
68.0
80.0
91.0
98.0
115.0
6.1
9.5
12.5
14.0
18.2
23.7
27.9
35.2
40.4
45.6
54.6
59.0
66.7
76.2
86.1
101.5
114.2
11.5
15.9
20.9
22.0
26.2
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4
101.5
110.3
123.3
0.90
0.90
0.90
1.25
1.25
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.00
3.15
3.15
3.15
3.15
1.00
1.25
1.25
1.60
1.60
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
3.15
4.00
4.00
4.00
24.0
24.0
30.5
37.5
37.5
46.0
55.0
60.0
70.0
75.0
80.0
89.0
99.0
114.0
123.0
133.4
146.1
24.4
26.6
33.3
40.5
40.5
51.0
61.0
66.5
78.6
83.2
89.0
101.6
111.1
128.6
138.0
147.8
161.9
Nominal
Protrusion
Length
Ordering
Reference
(Brass Metric)
58.5
58.5
60.5
67.5
67.5
69.5
78.0
75.5
80.5
91.5
92.0
99.0
102.0
120.0
148.0
169.0
183.0
20S16XXXX1RA
20XXXX1RA
20XXXX1RA
25XXXX1RA
25XXXX1RA
32XXXX1RA
40XXXX1RA
50SXXXX1RA
50XXXX1RA
63SXXXX1RA
63XXXX1RA
75SXXXX1RA
75E1FW1RA
90XXXX1RA
100XXXX1RA
115XXXX1RA
130XXXX1RA
20
16
E1W
1RA
20 E1FW
1RA
Cable Gland
Size & Type
Supply
Type
e.g. 20E1FW
1 - Gland
RA
Deluge Seal
Brass
1A
Metric
1A
2 - Pack
Brazilian
Certification
Aluminium
Imperial
2
3
4
2
3
4
PG
NPT
BSP
Nylon
Mild Steel
Stainless Steel
Brass - Fully
Nickel Plated
N/A
8
-
Entry Thread
Type
Material
CMP
STD
Suffix
Options
Selection Table Of STA/Braided Cable Glands Please replace XXXX in Ordering Reference with Cable Gland name i.e. E1FX
NPT / BSP /
NPSM
3/8
5/8
1/2
16
2
3
4
3/4
1
1-1/4
11
13.5
16
3/4
1
1-1/4
20
25
32
NPSM
1-1/2
21
1-1/2
40
BSPT
29
50
2-1/2
36
2-1/2
63
8
9
10
3
3-1/2
4
42
48
3
3-1/2
4
75
90
100
Imperial
1/2
PG
Unless otherwise stated, for IEC products, the standard Hazardous Area certification marking includes ATEX and IEC Ex as a minimum
please refer to CMP Products if your requirement differs from the standard
www.cmp-products.com
Metric
-
Cable
Gland
Size
20S/16
20S
20
25S
25
32
40
50S
50
63S
63
75S
75
90
100
115
130
Standard
Option
Metric
NPT
NPT
M20
M20
M20
M25
M25
M32
M40
M50
M50
M63
M63
M75
M75
M90
M100
M115
M130
1/2
1/2
1/2
3/4
3/4
1
1-1/4
1-1/2
2
2
2-1/2
2-1/2
3
3-1/2
-
3/4
3/4
3/4
1
1
1-1/4
1-1/2
2
2-1/2
2-1/2
3
3
3-1/2
3-1/2
-
Minimum
Thread
Length
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
Cable
Lead Sheath
Diameter
Overall Cable
Diameter
Min
Max
Min
Max
Min
Max
Max
Max
3.1
6.1
6.5
11.1
11.1
17.0
22.0
29.5
35.6
40.1
47.2
52.8
59.1
66.6
76.0
86.0
97.0
8.7
11.7
14.0
20.0
20.0
26.3
32.2
38.2
44.1
50.0
56.0
62.0
68.0
80.0
91.0
98.0
115.0
6.1
9.5
12.5
14.0
18.2
23.7
27.9
35.2
40.4
45.6
54.6
59.0
66.7
76.2
86.1
101.5
114.2
11.5
15.9
20.9
22.0
26.2
33.9
40.4
46.7
53.1
59.4
65.9
72.1
78.5
90.4
101.5
110.3
123.3
0.90
0.90
0.90
1.25
1.25
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.00
3.15
3.15
3.15
3.15
1.00
1.25
1.25
1.60
1.60
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
3.15
4.00
4.00
4.00
24.0
24.0
30.5
37.5
37.5
46.0
55.0
60.0
70.0
75.0
80.0
89.0
99.0
114.0
123.0
133.4
146.1
24.4
26.6
33.3
40.5
40.5
51.0
61.0
66.5
78.6
83.2
89.0
101.6
111.1
128.6
138.0
147.8
161.9
Armour Range
www.cmp-products.com
Across
Flats
Across
Corners
Nominal
Protrusion
Length
Ordering
Reference
(Brass Metric)
58.5
58.5
60.5
67.5
67.5
69.5
78.0
75.5
80.5
91.5
92.0
99.0
102.0
120.0
148.0
169.0
183.0
20S16XXXX1RA
20XXXX1RA
20XXXX1RA
25XXXX1RA
25XXXX1RA
32XXXX1RA
40XXXX1RA
50SXXXX1RA
50XXXX1RA
63SXXXX1RA
63XXXX1RA
75SXXXX1RA
75XXXX1RA
90XXXX1RA
100XXXX1RA
115XXXX1RA
130XXXX1RA
17