Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Es 3001

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Fact sheet

ES3001 RB211-24C to 24G upgrade


Provides increased power and heat rate, or extended life

Engineered solution purpose


This upgrade provides the option of
increased power and improved heat
rate or increased life when operating
at -24C ratings

Applicability
All RB211 -24C engines

Technical description
The upgrade replaces the High
Pressure [HP] turbine assembly.The
components replaced are the HP
blades, HP turbine disc and HP Nozzle
Guide Vanes [NGVs].The turbine
utilises Directionally Solidified [DS]
blades with improved cooling.
The upgraded materials allow higher
firing temperatures, which increase Benefits Experience
power and improve heat rate. If used The -24G rating provides an expected There are in excess of 240 RB211-24G
at the -24C firing temperatures, the power increase of 10% and 2.6% heat gas generators in service units with
materials provide extended rate improvement over the -24C. combined operational experience of
component life. When operating at -24C ratings, the - 4.5 million hours.
This rating typically provides a 3% 24G engine will operate at a firing 20 units have been converted to -
power increase when operating a - temperature 14 K cooler than a -24C 24G.
24G at -24C ratings into a RT56. engine, thereby giving an overall A partial list of customers includes:
To take advantage of the full turbine life improvement. Norsk Hydro - 7 units
potential for the increased power of The -24G blades provide a major Exxon Mobil - 2 units
the -24G, the power turbine must be improvement in creep life, with the PDVSA - 2 units
upgraded to the RT62/RT56 G rated potential increase as high as 50%.
turbine [ES4013] For further details please see table
showing power comparison of
different models in the chart on
page 2.
Fact sheet

Scope of work
Replace the existing HP turbine
assembly with Mod 1212
Control system modification

Bill of materials
HP turbine assembly (Mod 1212)
Thrust piston, if required (Mod 1044)
L5 vent revision, if required (Mod
1135)
Davis Valve (Mod 1136)
IP turbine disc cooling, if required RB211-24C gas generator
(Mod 1186)
Control system modification or
replacement
Undertaken
At overhaul
Bundling opportunities
RT62/RT56 RB211-24G rating upgrade
[ES4013]
RB211-DLE (Dry Low Emissions)
conversion [ES3003]
RB211-24G gas generator
RB211 T6 Thermocouple conversion
[ES3012]
Controls Upgrade [ES6006]

Nominal performance - Mechanical drive applications

Serial Package Gas Generator Power Turbine Power PT Speed


No. (PT) BHP (rated) rpm

1 Coberra 6456 RB211-24C RT56 33,360 4,950


2 Coberra 6556 RB211-24G RT56 34,900 4,950
3 Coberra 6556 RB211-24G DLE RT56 33,210 4,950

1 Coberra 6462 RB211-24C RT62 35,000 4,800


2 Coberra 6562 RB211-24G RT62 39,600 4,800
3 Coberra 6562 RB211-24G DLE RT62 37,880 4,800
Imperial units - ISO conditions, base load application, no losses, gaseous fuel.

While this information is given in good faith based on www.rolls-royce.com


the latest information available to Rolls-Royce plc, no www.energymanager-online.com
warranty or representation is given concerning such
information, which may be taken as establishing any ES131-10/03
contractual or other commitment binding upon Copyright © 2004 Rolls-Royce plc
Rolls-Royce plc or any of its subsidiary or associated Produced by Customer Information Centre
companies.