Xperiment ManualEE540L - FourthEdition
Xperiment ManualEE540L - FourthEdition
Xperiment ManualEE540L - FourthEdition
This work was carried out under the National Science Foundation (NSF)s
CAREER grant # ECCS-0845822 support
Dedicated to
My Parents
Preface
This revised version of experiment manual is intended for the upper division
undergraduate/graduate students in Electrical and Computer Engineering which is based
on the most recent version of Designer version 8.0 from Ansys. I have aimed to introduce
the modern trends in microwave components design, fabrication, and measurements. The
prerequisites for this EE540L course are EE540: Microwave Devices and Systems, and
EE440: Electromagnetic Waves II.
Chapter 1 introduces some of the microwave measurement equipments available
in the Antenna and Microwave Laboratory (AML). A tutorial on the Ansoft Designer
version 7.0 is presented in Chapter 2 which is widely used to analyze and design different
passive microwave components and devices. Chapters 3 and 4 focus on one port and two
port Vector Network Analyzer calibrations. Followed by this, design and characteristics
of the microstrip transmission line are presented in Chapter 5. Chapter 6 discusses design
of a 3 dB lossless power divider in microstrip version. Chapter 7 presents a 3dB
quadrature hybrid power divider/coupler. A rate-race or ring hybrid power
divider/coupler is discussed in Chapter 8. Design of microwave bandpass filter is
presented in Chapter 9. Finally, Chapter 10 introduces brief guidelines for preparing the
laboratory reports. The students will also be asked to complete a project report on a
broadband impedance matching transformer and some instruction help is added as an
appendix. The second project on Wilkinson power divider should also be completed.
Therefore, the students will be performing total 11 experiments during the semester.
I would like to thank all the students who have completed this laboratory course
since Spring 2008 till Spring 2014 under my instruction. The students feedbacks have
helped me in revising the manual. I would appreciate constructive comments of the
students who will be taking this course, both editorial and technical.
I would also thank my wife (Mamta) and daughters (Shiva and Shruti) for their
understanding and sparing their share of time throughout the preparation of this
Experiment Manual and, in general, my efforts towards the teaching and research
activities.
Table of Contents
Experiment # 1: Introduction to Microwave Measurement Equipment
5
Experiment # 2: A Tutorial on using Ansys Designer 7 Program for Design of
Microwave Components
14
Experiment # 3: One Port Calibration of Network Analyzer and Characterization of One
Port Microwave Devices
29
Experiment # 4: Two Port Calibration of Network Analyzer and Characterization of
Two Port Microwave Devices
35
Experiment # 5: Design, Fabrication and Measurement of Microstrip Transmission
Lines and Analysis of Results
40
Experiment # 6: Design, Fabrication and Measurement of Microstrip 3dB Lossless
Power Divider
48
Experiment # 7: Design, Fabrication and Measurement of Microstrip 3dB Quadrature
Hybrid Power Divider
54
Experiment # 8: Design of a 3 dB Microstrip 180 Hybrid Coupler (Rat-Race or Ring
Hybrid)
70
Experiment # 9: Design, Fabrication and Measurement of Microstrip Coupled Line
Bandpass Filter
80
Experiment # 10: Additional Two Projects and Guidelines for Preparing Laboratory
Reports
96
Appendix: Instruction Help for Designing Broadband Matching Transformer
Bibliography
97
103
Signal generators
Power meter
Spectrum analyzer
Noise figure meter
3. Signal Generators: In the context of this laboratory, a microwave signal can either be
a constant voltage signal over time (DC), or a varying voltage signal with respect to time
(AC). The focus of this section is related to AC signal sources. There are primarily two
signal sources; a non-synthesized signal source and a synthesized signal source. The
non-synthesized signal source operates by a voltage-controlled oscillator embedded
within various buffer and level stages. The synthesized voltage source uses the concept
of generating a frequency which is an integer multiple of the fundamental frequency,
implementing phase locked loops. A signal generator available in the Antenna and
Microwave Laboratory (AML) at SDSU is shown in Figure 1.
4. Power Meter: The power meter is a device which measures the power of either a
continuous wave or a pulsed coded system. However, when referring to the piece of
equipment, the power meter, there are actually two completely separate parts to the entire
system. There is the power meter, of which resides in the actual compartment that holds
the digital display, and then there is the power sensor that is a component attached to the
cables that feed into the box. The power meter section of this power system controls the
allowed frequencies ranges, and the peak power levels. The band of acceptable
frequencies can range from approximately 100kHz to 40GHz, pending on the design of
each respective system. The range of acceptable input power levels can be from 40dBm
to +20dBm, also pending on the design of each respective system. The power system can
only operate with both the power meter, and the power sensor.
The power sensor employs the balanced circuit bridge concept in order to measure
relative power levels. See Figure 4 for the photograph of the power meter system. When
the incoming waves enter the circuit, there is an imbalance sensed in the balanced bridge,
which directly correlates to the power measurement. Another balanced bridge, labeled as
the Thermistor is a component which is responsible for temperature compensation of the
circuit, and is linear in its operation.
Below is a summary of the expected terms to show up for the power meter and
power sensor instruments:
Power Meter
o Frequency range: This specifies the maximum and minimum frequency
capability.
o Power range: This parameter specifies the maximum and minimum amount of
power that can be measured with the respective power meter system.
o Accuracy: The specification sheet should identify the variation of the power
measurement itself.
o Noise: An important parameter to be known, especially for lower power signals,
because of the interference with the signal level that can be encountered.
o Drift: Drift is a metric of the variation of the measurement with time.
Power Sensor
o Frequency range: This specifies maximum and minimum frequency
capability, of which must be the same range for the power meter.
o Power range: This parameter specifies the maximum and minimum amount of
power the power sensor can sustain.
o Max SWR: The SWR specifies the matching capability of the sensor to the
input system being measured, so the user can understand the relative amount
of reflection from the power system.
10
(1)
12
13
-Under file, select new, and then click the Insert EM Design button:
14
-After doing so, a Layout Technology window will appear, in which a list of layout
types: Microstrip (MS), StripLine (SL), and Printed Circuit Board (PCB) will appear.
We are most interested in the microstrip (MS) layouts.
-Within each layout type, several variations of the substrate and trace materials are listed,
each with varying thickness.
***Note: 1mil=1/1000inch, 1mil=.0254mm
30mil=0.762mm
60mil=1.52mm, 0.5
oz copper = 17.5 m copper thickness
15
-After defining the appropriate substrate and trace materials, a project manager along
with the layout window will appear:
-To check or manipulate the material or layers of a design, you can select the Layer
dialogue.
-From this dialog we can alter the materials and thickness of each layer. The effect of the
substrate thickness and material has a large effect on performance which we will see in
our lab experiments.
16
- The layers tab, allows us to alter the color and pattern of the layers and objects we draw
in the layout. This can be helpful to see vias and other structures we add to our lines.
***Note: In version 8, the layout and stackup dialogue is combined. To only see outlines
of parts for improved visibility, one can enable layout > sketch mode or uncheck the
wireframe box in the layers tab (pink icon).
-Within the layout window, the microstrip geometry can be constructed. To draw the
model, first choose the appropriate polygon type, and using the mouse, trace out the
17
desired geometry. Be sure to note the the desired Active Layer is selected. Default is the
Trace, or top layer.
-After tracing out the desired geometry, one can double click the geometry, after which a
Properties window will appear with a list of dimentions. This can be used to further edit
the geometery to the desired dimentions. Factors such as the radius, center point location
can be manipulated through this window.
18
-Double click on Via to find Via Properties. Next right click to find Coax Probe, under
EM Design Properties. Doing so opens up a 2.5DVia Properties window.
19
-In the Via Properties window one must specifie both the upper and lower layers for the
via. For a coaxial exitation, the upper layer is the trace layer, while the lower is the
ground layer.
-Under the Upper Layer tab, select Trace as the upper layer with no load as the
excitation/load type.
-Select Ground under the Lower Layer tab, with coaxial exciation as the
excitation/load type. Be sure to specifie the Characteristic impedace, (50ohm for the
SMA connector), and the appriopriate magnitude and phase of the excitation. The
default settings here are suitable for most designs.
***Note: For Ansoft Designer 5, you must right-click excitations in the project manager
and convert vias to coax probes. For Ansoft Designer 7, you must right-click the via and
select "Coax Probe".
-Under the Physical Properties tab, specify the hole diameter, (1.2mm for a standard
SMA), and the Via material, (copper most likely). For this type of excitaion, one has the
option to also select Mesh as a 3D via for a more accurate simulation.
-Edge Port Excitations: A edge port excitation, is one in which the excitation is
provided through a microstrip transmission line. This transmission line must have a
uniform cross section through which the current is transmitted. In our geometry, we must
first create the transmission line to which the edge port excitation is applied to.
-Create a transmission line by drawing a rectangular box of appropriate width such that it
intersects antenna geometry . **Note: The width of this transmission line determines the
20
characteristic impedance of the line. See notes on using the Planer EM Estimator at the
end of this section**
-After highlighting both the transmission line and the antenna geometry, select
LayoutMerge PolygonsUnion at the top of the project window.
21
-Right click the Excitations link in the project manager, and select Add port in the
drop down window. After doing so, a port will be created, Port 1 in the project
manager, along with the port labeled in the layout window.
-By double clicking the Port 1 link in the project manager, a Edge Port definition
window will appear. Be sure the gap source box is not checked, as this is different type
of excitation. To disable gap source in Ansoft Designer 7 and higher, select Default [Zo =
50 ohm] rather than the Port Solver. Also uncheck the Ignore Reference option.
-Using the EM Estimator: This is a useful tool which can be used to quickly estimate
various microstrip parameters; such as the characteristic impedance and the line loss.
-Under the Planer EM option on the menu bar, select Estimate
-Doing so will bring up an Estimate window. Under this window there are various
calculations options; the one of most interest here is the TLine estimator. Within this
option, one can calculate the appropriate Width in mm of the microstrip transmission line
for a desired Impedance value, as well as the TLine Loss and the Guided Wavelength at
a particular frequency. This tool is invaluable in the design of microstrip antennas.
**This concludes the steps needed in the construction of a microstrip antenna in
Designer***
-Before a simulation study can be performed, one must define the type of simulation, as
well as the simulation settings. Care must be taken during these steps to ensure accurate
results; all the while not introducing lengthy calculation settings that can increase the
simulation time that may not be appropriate for the more basic designs.
22
-Defining and Executing Simulations: Under the project manager, right click the
Analysis link.
-Select the Add Planar EM Solution Setup in the drop down window. Doing so will
bring up a Setup 1 window:
-Within the Planar EM Setup 1 window, are the various General and Advanced Meshing
settings. These settings define the level refinement of the mesh in which the simulator
uses to solve the Method of Moments equations.
23
-Under the General tab, are a list of parameters that will determine the level of accuracy,
and the speed of the simulation. The Fixed Mesh option specifies a uniform mesh to be
generated at the Frequency specified. This setting does not refine the mesh at sharp
corners or edges of the geometry. Depending on the geometry, and may lead to longer
simulation time and degradation in accuracy.
-The initial mesh Frequency, is the frequency in which the mesh is generated which
remains fixed over the entire frequency sweep. A good rule of thumb is to specify the
highest frequency in the proposed frequency sweep, since this generates the finest mesh
size, leading to the most accurate results. On the other hand, a finer mesh size leads to
more unknowns in the solution, which leads to a longer simulation time. Depending on
the complexity of the geometry, a compromise may be required.
-By selecting the Use Edge Mesh checkbox, the mesh at the initial mesh Frequency, is
further refined at the edges of the geometry where the electromagnetic fields are most
critical. Selecting this option can significantly increase the accuracy, and reduce
simulation time, depending upon the geometry. The default value for the Edge mesh to
length ratio is adequate for most designs.
-The Standard and Advanced Adaptive option, uses an adaptive iterative process to
determine the best mesh size given the Adaptive Parameters. This option typically not
necessary for the more basic designs.
-Defining a Frequency Sweep:
24
-Two types of frequency sweeps can be defined: Discrete and Interpolating; as shown in
the top of the Sweep 1 window.
-A Discrete sweep solves Maxwells equations at each and every frequency defined in
the sweep. This is most accurate, but also the more time consuming of the two sweep
types.
-In an Interpolating sweep, the simulator finds solutions at a minimum of two frequency
points in the sweep. A interpolating function is generated from these two solutions, and
a estimate solution is made for all frequency points in the sweep. If the solution at these
two points does not lie within a pre-defined accuracy level, a third point is sought. The
simulator will continue to seek solutions at more frequency points within the frequency
range until the accuracy threshold is met.
-To specify the frequency range, type the Start and Stop frequencies, along with the Step
size.
-Be sure to select the Generate Surface Current checkbox, for the far field radiation
patterns.
-To execute the simulation, right click the Sweep 1 link in the project manager, and
select Analyze from the drop down window or by pressing the F10 button.
-At the bottom of the project window, the following windows will appear indicating a
successful launch of the simulation:
25
***This concludes the steps needed to define and execute a successful simulation in
Designer***
-After executing a simulation, one must specify the types of results to be viewed by the
generation of plot types, in the post processing of the simulation results.
-Viewing Results and Post Processing: After the completion of a successful simulation,
one can specify the types of results that are of interest. The two most common results
that are of interest in antenna design are the Return Loss and the Far Field Radiation
Patterns.
-Generating a Return Loss plot: Under the project manager, right click the Results
link, and select Create Standard Report from the drop down window and Rectangular
Plot as the display type.
26
-Under the Category window, select S Parameter, along with S(Port1,Port1) under the
Quantity window, and dB under the Function window, to ensure units are in dB. Click
New Report at the bottom, and a return loss plot should appear. The result will vary
depending on the size the structure and material properties. Feel free to alter parameters
or options to become more comfortable with the program.
- You can make plots much more clear by adding markers (right-click an empty area on
the plot), you can alter the line style and color by double-clicking the line, and you can
27
alter the scale by double-clicking the numbers in either axis. You can alter the name of
each plot by double-clicking the name in the project manager.
***This concludes the steps needed for the post processing of simulation results in
Designer***
Note, more specific modeling steps will be discussed when discussing the design of a
specific microwave component. However, these instructions are merely guidelines and
some steps may change as newer versions of the Ansoft Designer tools are released. Also
these are instructor/contributors guidelines and not from the software.
28
29
Using the START key within the Stimulus feature area, and the number pad in the
Entry area, set the measurement start frequency to 2 GHz by pressing START, 2 G/n.
Set the top of the frequency range to 3 GHz using the STOP key in a similar fashion.
By pressing the CENTER and SPAN keys in the Stimulus box as well, the display will
show the center frequency 2.5 GHz and the frequency range, 1 GHz. Once the frequency
range over which measurements will be made is set, the machine can be calibrated. The
calibration process requires the use of very delicate, specially designed standards
modeling open, short and 50 Ohm circuits. These standards can be found in the wooden
box marked 85031 B 7mm Calibration Kit as shown in the picture on the next page.
These are the standards for the APC 7 connectors on Ports 1 and 2, the attachments on the
front of the S-parameter test set. The first calibration will be for a one port.
4.
The calibration sequence is as follows: push the CAL key, located in the Response
panel area. Using the soft keys, hit CALIBRATE MENUS and S11 1-PORT.
30
5.
Spin the knob of the connector on Port 1 until the threads of the APC 7 are fully
exposed. Spin the knob on the open circuit calibration standard the opposite
direction, so the threads are recessed. Fitting the two together, turn the calibration
standard until they are connected. These are tricky connectors and may not fit the
first time, it occasionally takes a few tries.
6.
Once the calibration standard is in its place, push the corresponding soft key.
Once the
8753 beeps and Open is underlined, remove the open standard and
repeat the same procedure for
the short and 50 Ohm load. When these are
finished, push the key corresponding to Done 1- Port Cal.
The calibration is
complete.
31
Since we will not be content to only make measurements on one-port devices over
the single frequency range of 2 GHz to 3 GHz, and will surely recalibrate, it is convenient
to save this particular calibration in case it is needed later. To do this, press the
SAVE/RECALL hard key located in the Instrument State area. Push one of the soft keys
corresponding to a particular register on the following menu. This saves the calibration,
allowing it to be recalled through the use of the RECALL hard key in the Instrument
State feature area. This storage is pseudo-permanent, it usually saves what is in the
register at least overnight, up to 36 or 48 hours.
7.
The next step is to put the calibration we just performed to use. Using the
DISPLAY hard key in the Response area, store the present machine state in
temporary memory by hitting Data Memory.
8.
9.
Attach the APC 7 to SMA adapter to the APC 7 connector of the cable.
32
11.
12.
The MKR hard key yields a soft key menu with four markers (#1 through 4).
Activate marker 1 with its key, and use the knob in the Entry panel area to move it along
the trace. Experiment with movement of the marker with the knob, up and down arrow
keys and number pad, all of which are located in the Entry feature area. The number pad
enables the placement of a marker at an exact frequency (i.e., pushing 200 M/u, places
the marker at 200 MHz). The 8753 is designed so that only one of its four markers is
activated at one time, but in some other models of the same network analyzer more than
one marker can be also activated. This is indicated by the positioning of the marker
arrow. A triangle with its point down indicates that the marker is active. Data is
displayed for the positions of the inactive markers, but only the activated one responds to
positioning commands.
13.
Position marker 1 at the minimum value of S11 on the log magnitude trace. This is
the frequency where the antenna is best matched. What is the corresponding
frequency?
33
Figure 8: Marker one placed at minimum S11 value on log magnitude trace
14.
The trace can also be displayed on a Smith Chart by pushing the FORMAT hard
key in the Response panel area, and then the Smith Chart soft key.
15.
To see the difference calibration makes on the trace, push the DISPLAY hard key,
followed by the Data soft key. This produces a measurement of the devices
frequency response that includes the parasitics caused by the adapters. The
Data/Memory makes use of the calibration by dividing out the effects of the
connectors, displaying only the resistors behavior.
16.
Return the display state to Data/Memory. How big an effect does calibration
have on the trace?
34
Figure 10: Smith Chart displayed using the DATA option (uncalibrated
results)
35
2.
Using the START key within the Stimulus feature area, and the number pad in the
Entry area, set the measurement start frequency to 2 GHz by pressing START, 2 G/n.
3.
Set the top of the frequency to 3 GHz using the STOP key in a similar fashion.
4.
The calibration sequence is as follows: push the CAL key, located in the Response
panel area. Using the soft keys, hit CALIBRATE MENUS and FULL 2-PORT.
There will now be three options available, Reflection, Transmission, and Isolation.
Together, these make up the two-port calibration process.
5.
Press the "Reflection" soft key. Six options will be displayed in two categories.
Under the "Forward:" category, OPEN, SHORT, and LOAD will be displayed. Forward
refers to port 1, so use the provided calibration standards to calibrate port 1. After this is
done, switch to port two for the "Reverse:" category, and calibrate it using the open,
short, and load calibration standards. When you are finished, all 6 of the options should
be underlined. Press the "STANDARDS DONE" soft key to continue.
6.
Press the "Transmission" soft key. This portion of the calibration requires ports
one and two to be connected together. To do this, spin the knob of the connector on port
1 until the threads of the APC 7 are fully exposed. Spin the knob of the connector on
port 2 the opposite direction, so the threads are recessed. Fitting the two together, spin
the knob of the connector on port 2 until it is locked tight over port 1's threads, then
spin the knob of the connector on port 1 until it locks tight against port 2's knob.
7.
There are four options in the Transmission portion of the calibration process,
including "FWD MATCH THRU," "FWD TRANS THRU," and corresponding reverse
options. Press each of the four soft key options in order, waiting for the beep after each
option to indicate it has finished calibrating. When this is complete, press the done soft
key.
36
Figure 11: Cables connected together for the transmission portion of 2-port calibration
8.
The final step in the calibration process is Isolation. Press the "Isolation" soft key.
9.
10.
11.
12.
13.
Press the DISPLAY hard key located in the Response area of the network
analyzer. Press the "Data Memory soft key to temporarily store the results of the
calibration.
Now the two port calibration is complete. You should see the lights above the port 1 and
port 2 connectors blinking back and forth. Next, we will characterize a two-port
microwave component in this manual. You will be asked to characterize additional types
of the 2-port microwave components and find their scattering parameters.
37
15.
17.
The MKR hard key yields a soft key menu with four markers (#1 through 4).
Activate marker 1 with its key, and use the knob in the Entry panel area to move it along
the trace. Experiment with movement of the marker with the knob, up and down arrow
38
keys and number pad, all of which are located in the Entry feature area. The number pad
enables the placement of a marker at an exact frequency (i.e.,pushing 200 M/u, places the
marker at 200 MHz). The 8753 is designed so that only one of its four markers is
activated at one time, however some models can show more than one marker. This is
indicated by the positioning of the marker arrow. A triangle with its point down indicates
that the marker is active. Data is displayed for the positions of the inactive markers, but
only the activated one responds to positioning commands.
18.
Position markers at the minimum value of S11/S22, and at the start and end of the
frequency where S11/S22 is -10dB on the trace. The start and end of the frequency of the
trace can be used to calculate the bandwidth of the filter.
19.
The network analyzer can also display S12/S21. To do this, press the MEAS hard
key, then press the soft key corresponding to "Trans: FWD S21 (B/R)." The markers now
appear on the S12/S21 log magnitude trace, which can be used to measure possible loss in
the filter response. Please note this is a bandpass filter which differs from a bandstop
filter response. This is the frequency where the device is best matched.
20.
The traces can be displayed on a Smith Chart by pushing the FORMAT hard key
in the Response panel area, and then the Smith Chart soft key.
39
There are four scattering parameters, as can be seen in Figure 1; S11, S12, S21, and
S22. Each scattering parameter represents a criterion of the circuit as defined below:
All the results presented here can be generated using the full wave analysis i.e.
Ansoft Designer as discussed in Experiment # 2.
2. Theory: In this lab, several simulations are performed to observe the effects for
varying design parameters for a quasi-TEM microstrip transmission line. Critical
parameters for the designs in this lab are the relative permittivity (r) of a substrate
material, the characteristic impedance (Zo), substrate thickness, conductor thickness,
operating frequency, the particular termination ports used for each line, and the
conductivity values. The following is a basic side view cross-section schematic of a
microstrip transmission line.
41
varying the characteristic impedance from 50, 75 to 100, for a constant relative
permittivity of 4.4 (FR-4) using the 50 via port connectors at the ends of the line. For
ease in feeding these lines different diameters of inner conductor were selected.
(iii) The third requirement of this lab is to study change while varying the substrate
material. Repeat requirement (ii) and compare the microstrip line parameters when
changing the substrate material from a constant relative permittivity of 4.4 (FR-4) to 1.06
(Foam).
(iv) The last investigation of this lab is to compare the differences between the results of
a simulation across a microstrip transmission line, where the conducting line is a perfect
electric conductor (PEC), ~ , and a copper conductor, = 5.8107 S/m. Thus, here,
the effects between the cases of a PEC to a finite conductivity simulation using Ansoft
Designer will be investigated.
3. Simulation: First, we must model a microstrip transmission line.
1. Insert an EM design (sometimes named planar EM design) into a new project.
42
3. Using the estimator tool (under the EM design) determine the physical properties of a
50 ohm transmission line.
4. Draw a rectangular polygon and input the appropriate dimensions by double clicking
the polygon. Pt A is the starting point, you can set this as the origin and pick Pt B to be
the end point for the diagonally opposite corner for the polygon in the (x, y) coordinate
plane. Use 100mm as your line length.
43
5. The first requirement is to compare via port and edge port excitations. Place 1.2mm
diameter via ports on both sides of the line as seen in the figure below, assign coax probe
excitations to both vias by right-clicking them.
6. Set up your analysis and frequency sweep from 2-3 GHz and run the simulation.
44
6. Save the project, insert another EM design and create an edge-port excited version of
the same line for comparison (you can copy and paste the previous line to save time).
Via Port
-22.50
Edge Port
-35.00
Name
m1
m1
Name
-25.00
m1
Curve Info
m1
2.5000 -36.1306
dB(S(Port1,Port1))
PlanarEM Setup 1 : Sw eep 1
-36.25
2.5000 -24.3615
Curve Info
dB(S(Port2,Port2))
PlanarEM Setup 1 : Sw eep 1
dB(S(via_1,via_1))
PlanarEM Setup 1 : Sw eep 1
-37.50
dB(S(via_2,via_2))
PlanarEM Setup 1 : Sw eep 1
Y1
Y1
-27.50
-38.75
-30.00
-40.00
-32.50
-41.25
-35.00
-42.50
2.00
2.20
2.40
2.60
2.80
3.00
2.00
2.20
2.40
F [GHz]
2.60
2.80
3.00
F [GHz]
Via Port
-0.60
0.00
Edge Port
m1
-0.65
Curve Info
-0.10
Name
m1
-0.70
dB(S(via_1,via_2))
PlanarEM Setup 1 : Sw eep 1
Y1
m1
dB(S(Port1,Port2))
PlanarEM Setup 1 : Sw eep 1
dB(S(Port2,Port1))
PlanarEM Setup 1 : Sw eep 1
-0.30
dB(S(via_2,via_1))
PlanarEM Setup 1 : Sw eep 1
2.5000 -0.9181
Y1
Name
-0.80
2.5000 -0.0425
-0.20
Curve Info
-0.75
-0.40
-0.85
-0.50
m1
-0.90
-0.60
-0.95
-0.70
-1.00
-1.05
-0.80
2.00
2.20
2.40
2.60
F [GHz]
(a)
2.80
3.00
2.00
2.20
2.40
2.60
2.80
3.00
F [GHz]
(b)
Figure 1: (a) Via Port vs. (b) Edge Port Simulation Results
45
Estimated
line width
(mm)
Estimated
Dielectric
Attenuation
(dB/m)
Estimated
Conductor
Attenuation
(dB/m)
Estimated
Total
Attenuation
(dB/m)
Simulated
Loss S12
and S21
(dB)
Simulated
Return
Loss S11
and S22
(dB)
Reflection
Coefficient
()
SWR
Via port
Edgeport
46
3.2 Varying characteristic impedance (Zo) with constant permittivity (r) = 4.4
Operating frequency = 2.5GHz Via port = Variable Zo = Variable r = 4.4 h = 60 mil
Table 2: Results from varying characteristic impedance
Characteristic
Impedance Zo
Estimated
Line
Width
(mm)
Estimated
Dielectric
Attenuation
(dB/m)
Estimated
Conductor
Attenuation
(dB/m)
Estimated
Total
Attenuation
(dB/m)
Simulated
Loss S12
and S21
(dB)
Simulated
Return
Loss S11
and S22
(dB)
Reflection
Coefficient
()
SWR
Via Port
Diameter
50
75
100
1.2mm
0.6mm
0.3mm
Estimated
Line
Width
(mm)
Estimated
Dielectric
Attenuation
(dB/m)
Estimated
Conductor
Attenuation
(dB/m)
Estimated
Total
Attenuation
(dB/m)
Simulated
Loss S12
and S21
(dB)
Simulated
Return
Loss S11
and S22
(dB)
Reflection
Coefficient
()
SWR
Via Port
Diameter
50
75
100
1.2mm
1.2mm
1.2mm
3.3 Comparison between Perfect Electric Conductor Vs. Copper Conductor simulation
Operating frequency = 2.5GHz for results in Table 4, Via port = 1.2mm
Table 3: Results from PEC vs. Copper 50 microstrip line simulation
(Copper conductivity = 5.8 x 107 S/m)
Type of
conductor
Estimated
line width
(mm)
Estimated
Dielectric
Attenuation
(dB/m)
Estimated
Conductor
Attenuation
(dB/m)
Estimated
Total
Attenuation
(dB/m)
Calculated
loss
across 10
cm line
(dB)
Simulated
Loss S12
and S21
(dB)
Simulated
Return
Loss S11
and S22
(dB)
Reflection
Coefficient
()
Copper
PEC
47
SWR
10
RL
20
no units
(1)
With calculation of the reflection coefficient, the standing wave ratio can then be
calculated, using the following relationship, and are shown in the last column in Table 1:
SWR
1
(2)
For the via port setting, the reflection coefficient is not zero, and has a finite
value. This means there is reflection of the incident wave, therefore the return loss is
higher for the via port setting. However, the via port setting emulates practical constraints
in the real world, and not like in an idealized matching network in the edge port case.
4.2 Varying Characteristic Impedance (Zo) with constant permittivity (r) = 4.4: The
simulation results show a definite trend, that with increasing characteristic impedance,
there is a decrease in the conducting line width. Also, it can be extrapolated from the
simulation results, that with increasing impedance, the dielectric attenuation decreased,
while the conductor attenuation increased.
Initially, increasing conductor attenuation with a decreasing line width is not
intuitive, because with decreasing line width there is less volume for current to be
conducted. However, with decreasing line width, this implies that the electric and
magnetic field lines are converged more closely together. This convergence induces
higher current in the microstrip line, which causes more conductive losses in the line due
to I2R losses. This also implies that the field lines are not dispersed across more area
along the substrate, and therefore the dielectric attenuation decreases.
In the plots of the via port excitation after Table 1, there are plots for the
transmission and return loss versus a frequency sweep from 1 to 3 GHz with a step of
0.05 GHz. Most notably, these graphs are non-linear, and show an undulation for both
return and transmission loss with change in frequency change.
An important aspect of these graphs is that they are plots with two parameters
each; the first set of plots display parameters S11 and S22, while the second set of plots
display S12 and S21. It can be approximated that parameters S11=S22 and also S12=S21,
because we have a two-port network connected by a microstrip line alone, and are also
assuming that the microstrips conducting line and substrate are comprised of
homogenous, isotropic materials. For Tables 1 through 3, these parameters are coupled
together under transmission (S12, S21) and return (S11, S22) loss.
4.3 Comparison between perfect electric conductor vs. copper conductor simulation
Ansoft Designer automatically sets the conductivity value for PEC to = 1030 S/m
i.e. approaching infinite conductivity. In the conductor attenuation column of Table 3, the
PEC attenuation is on the order of 10-12, while the copper conductor attenuation is on the
order of 10-1, which is a reasonable expectation between the two separate cases. Both
dielectric attenuations are constant at 7.713 dB/m. Hence, the total attenuation is less for
the PEC simulation which calculates to 0.771dB loss across a 10cm long line, in
comparison to the 0.820dB drop of the practical copper simulation.
48
P1
Power Divider
Rt R1 R2
We cannot just connect the 50 output ports (port #2, port #3) to the 100 microstrip.
This mismatch would cause reflection due to impedance mismatch at port #1. We use a
quarter wave transformers to match the two impedances.
Z o Z1 Z 2
(2)
Z1 and Z2 are the impedances of 100 legs, and Zo is the intrinsic impedance of the
quarter wave transformer. We use these impedances to find the strip width of each
component in the power divider. The impedance of a microstrip depends on the
properties of the substrate used, mainly the dielectric constant (relative permittivity r)
width (w), and height (h). Because the wave propagation is in the transmission medium
and not free space, it is necessary to find the effective permittivity (eff).
49
eff
r 1
2
r 1
(3)
h
2 1 12
w
Unfortunately this is not obvious. Effective permittivity must be derived. When the
width, height, and intrinsic impedance of the transmission line are known, we can use the
following equations to solve the effective impedance:
Zo
60
eff
8h w
ln ;
w 4h
w
1
h
1
120
;
Zo
w
w
eff
1.393 0.667 ln 1.44
h
(4)
w
1
h
(5)
When the width and height are not known, but the intrinsic impedance and dielectric
constant are, we can use the following equations:
w
8e A
2A
;
h e 2
w
2
h
(6)
w 2
1
0.61
B 1 ln( 2 B 1) r
;
ln( B 1) 0.39
h
2 r
r
w
2
h
(7)
Zo r 1 r 1
0.11
0.23
60
2
r 1
r
(8)
60 2
Zo r
(9)
We start by assuming the ratio is less than 2. If when the first equation is solved the ratio
is greater than 2, use the second w/h equation. Using the w/h ratio to solve effective
permittivity, the wave length can be solved.
C
f eff
(10)
50
The dimensions of the quarter wavelength transformer, 50 Ohms and 100 Ohm strips can
now be used to construct the power divider. We were given a restriction of 100mm x
100mm for the area of power divider design, and to keep the design away from the edges
to avoid fringing fields. Some of the dimensions are given in the tables below. The rest
of the dimensions should be calculated. This can be done with the aid of the Estimate
tool, The top view of the power divider is shown in Figure 2. One should notice that the
length of 50ohm lines and 100ohm lines are selected arbitrary and have negligible effect
on the circuit respond. But the length of the transformer is critical and frequency
dependent. This length should be selected based on the design frequency (/4 electrical
length)
Table 1: Design parameters for a 3 dB Power Divider on FR-4 (h = 60mil, r = 4.4, tan
= 0.02). Find the rest of the dimensions.
Width (mm)
Length
(mm)
Port 1
(50)
First
100 Line
Second
100 Line
20
50
50
/4
Transformer
(70.71)
Port 2, 3
(50)
20
Table 2: Design parameters for a 3 dB Power Divider on foam (h = 60mil, r = 1.06, tan
= 0.002). Find the rest of the dimensions.
Width (mm)
Length
(mm)
Port 1
(50)
First
100 Line
Second
100 Line
20
50
50
/4
Transformer
(70.71)
Port 2, 3
(50)
20
***Note: Foam is not a standart material in Designer library and you are requierd to
create such a material. To do so, you select Layers dialog then click the material for the
dialectric layer (currently showing FR-4 ). By clicking Edit, the material library would
be open. The you need to select Add Material and inserting the properrties of the foam
(Permitivity= 1.06, Diecteric Loss Tang= 0.002 and the rest as defult).
51
Figure 3: Port #1 return loss and transmission parameters (S11 S12 S13)
52
S21, S22, m1
S23
EMDesign2
ANSOFT
-3.00
-4.00
-5.00
m2
m3
Y1
-6.00
Curve Info
dB(S(Port2,Port1))
PlanarEM Setup 1 : Sw eep 1
dB(S(Port2,Port2))
PlanarEM Setup 1 : Sw eep 1
-7.00
dB(S(Port2,Port3))
PlanarEM Setup 1 : Sw eep 1
-8.00
Name
-9.00
m1
2.5000 -3.0933
m2
2.5000 -6.0126
m3
2.5000 -6.3580
-10.00
-11.00
2.00
2.20
2.40
2.60
2.80
3.00
F [GHz]
Figure 3: Port #2 return loss and transmission parameters (S21 S22 S23)
S31, S32, S33 (Return
Loss)
m1
EMDesign2
ANSOFT
-3.00
Name
-4.00
-5.00
m1
2.5000 -3.0934
m2
2.5000 -6.0124
m3
2.5000 -6.3580
m2
m3
-6.00
Curve Info
Y1
dB(S(Port3,Port1))
PlanarEM Setup 1 : Sw eep 1
dB(S(Port3,Port2))
PlanarEM Setup 1 : Sw eep 1
-7.00
dB(S(Port3,Port3))
PlanarEM Setup 1 : Sw eep 1
-8.00
-9.00
-10.00
-11.00
2.00
2.20
2.40
2.60
2.80
3.00
F [GHz]
Figure 4: Port #3 return loss and transmission parameters (S31 S32 S33)
53
EMDesign2
ANSOFT
-3.00
Name
-4.00
-5.00
m1
2.5000 -3.0934
m2
2.5000 -6.0124
m3
2.5000 -6.3580
m2
m3
-6.00
Curve Info
Y1
dB(S(Port3,Port1))
PlanarEM Setup 1 : Sw eep 1
dB(S(Port3,Port2))
PlanarEM Setup 1 : Sw eep 1
-7.00
dB(S(Port3,Port3))
PlanarEM Setup 1 : Sw eep 1
-8.00
-9.00
-10.00
-11.00
2.00
2.20
2.40
2.60
2.80
3.00
F [GHz]
S12
S22
S32
-3.0933 dB
-6.0126 dB
-6.358 dB
S13
S23
S33
-3.0933 dB
-6.358 dB
-6.0124 dB
54
55
To derive the power divider equations, Pozar [2] uses even-odd mode analysis.
Without re-writing his derivation, the theory behind it is summarized. Assuming this is a
power divider in transmit mode and not a power combiner or coupler in receive mode, a
signal will enter at Port 1 as shown in the above figure. The signal will then be split
evenly (the impedances of port 2 and port 3 are equal) between the two transmission
lines, with identical amplitude and 90 deg phase at port 3 while phase at port 1 is 0 deg.
Port 4 sees no power hence is isolated port. To achieve this, port line impedances are Z o
while two arms are of Zo/2.
3.Ansoft Designer Simulations: The designs steps are given below:
1.
2.
3.
56
4.
5.
Press
6.
Press the Add Material button at the bottom of the resulting screen.
7.
In the following screen, set the Material Name to Foam, the relative permittivity
to 1.06, and the dielectric loss tangent to 0.002. Press OK, then double-click
the Foam entry in the materials list.
the
FR4_epoxy
button
under
the
Material
column.
57
8.
9.
10.
Select the Components tab under the project manager, then Nexxim Circuit
Elements Distributed Microstrip Transmission Lines MS_TRL
(Physical Length).
12.
13.
Press the button labeled FR4 in the value column of the resulting screen.
58
14.
Highlight FR4 and press remove, then press the New button.
15.
Change the substrate name to Foam, then press the Select button.
59
16.
Make sure Foam is selected in the drop down box, then press OK. Verify
that in the following screen the dielectric values are grayed out and match the
values you entered for foam in step 7.
17.
Exit through all of the dialog boxes, and then select the transmission line in your
schematic by left-clicking on it once. Copy it by pressing CTRL-C, then paste 7
copies of the line into your schematic, for a total of 8 transmission lines. Wire the
components as shown below. Note the order of the ports.
60
18.
For each of the transmission lines labeled as 1 in the figure in step 7, doubleclick the transmission line and press the TRL button.
61
19.
Set Z0 = 50, electrical length to 90 degrees, and frequency to 2.4 GHz. Press the
Synthesis button, then press Place. Press OK in the properties box.
20.
Repeat steps 18 and 19 for the transmission lines labeled as 2. Set Z0 = 35.35,
electrical length to 90 degrees, and frequency to 2.4 GHz.
21.
Repeat steps 18 and 19 for the transmission lines labeled as 3. Set Z0 = 50,
electrical length to 90 degrees, and frequency to 2.4 GHz.
22.
Select the Layout Editor by right-clicking on your Nexxim circuit in the project
manager.
62
23.
The result will be a jumbled mess. Ports can be snapped to their respective
transmission lines by selecting the line, then control-clicking the port and pressing
CTRL-M. To connect the transmission lines together, it may be easier to disable
snapping in the Grid Settings option under Layout. Uncheck the boxes
under the Snapping tab.
24.
63
25.
Press CTRL-A to select the entire structure, then go to Edit Copy to Planar
EM.
26.
Select and delete all four ports in the resulting Planar EM screen, then press the
Select Edges button.
64
27.
Select the edge that will be port 1, then press the Create edge port button.
28.
Repeat this step for all four ports, maintaining the same port order as the original
layout.
29.
Press CTRL-A to select the entire structure, then click Layout Merge Polygons
Union.
30.
In the project manager, right click on Analysis under the Planar EM file, and
click Add Solution Setup.
65
31.
In the following screen, set the frequency to 2.4 GHz, and check the Use Edge
Mesh box.
32.
In the following screen, select the current sweep in the box on the right, then
change the Type to Linear Step, Start to 2 GHz, Stop to 3 GHz, and Step to 0.025
GHz, then click Update, then OK.
66
33.
34.
67
35.
36.
In the same screen, switch the Function column to ang_deg then select S21
and S31 only. Press the New Report button.
4. Simulation Results: The simulated results of the power divider are given below
which show scattering parameter values versus frequency between different ports.
Figure 2: Scattering parameters (S11, S21, S31, S41) considering input port 1 and output
ports 2 and 3 and isolation port 4.
Figure 2shows that at the design frequency 2.4 GHz, power division is around 3.5 dB
while impedance match is about -23dB and isolation is also around -23 dB.
68
Figure 3: Scattering parameter phase response from input port 1 to output ports 2 and 3
showing that around 90deg phase difference is observed between the output ports which
is required for a quadrature power divider.
5. Discussion of Results: As can be seen in Figure 2, the results closely match the
theoretical results predicted in Chapter 7 of Pozar [2]. S21 and S31 intersect at exactly 2.4
GHz, which is the design frequency. The S31 and S21 are not the ideal -3 dB, instead they
are at approximately -3.5 dB. This means that while the output power has been equally
split as desired, we do not in practice have lossless transmission lines, and so the total
output power is slightly less than the ideal case. Also shown in Figure 2 is the S41
isolation and S11 matching. At the design frequency, the isolation is better than -23 dB,
while the S11 matching is better than -23 dB. The power lost due to reflections at port 1
and due to non-perfect isolation of port 4 also contribute to S21 and S31 being slightly less
than -3 dB. Figure 3 shows the phase relationship between the output ports 2 and 3. As
can be seen, at design frequency the output ports 2 and 3 are 90 degrees out of phase.
Below the scattering parameters for an ideal and designed hybrid coupler is compared.
0 j 1 0
1 j 0 0 1
[S]Ideal =
2 1 0 0 j
0 1 j 0
Please fill S-parameter matrix based on your simulated and measured results and include
in your laboratory report.
69
70
Pozar [2] derives the scattering coefficients using even-odd mode analysis. In
summary, the ideal scattering matrix of a rat-race hybrid is:
[ ]
one can see that the scattering matrix is symmetric and reciprocal.
3. Design of Rat-Race Hybrid: The circumference of the ring is 6 /4. Knowing this we
can calculate the radius of the ring. We know the material, material thickness, and design
frequency.
The circumference of the ring will be
where
which we can use to calculate the width of the ring. Some of these dimensions
can also be easily discovered using Ansoft Designer's estimator tool.
Ring Radius
16.368 mm
Width (Ring)
1.615 mm
3.051 mm
71
72
When all shapes are properly placed, you can union your shapes by selecting Layout >
Merge Polygons > Union when all shapes are selected.
Figure 2: Rat Race Hybrid modeled in Ansoft Designer (Sketch Mode Enabled)
6. Add excitations. One needs to excite each port to perform simulations. In figure 2,
each port was excited using coaxial excitations. Edge ports are also a possibility. Edge
ports are ideal excitations but vias will show more realizable results as if one were using
SMAs.
73
To create an edge port, just select an edge by pressing the Select edges button, select the
edge and pressing the Create edge port button.
To create a via with coaxial excitation, press the Insert via button and add the via to your
model. Double click the via to check if the via is properly placed and sized (1.2mm).
Right click the via and select Add EM Design Via. Right click the via again and select
Coax Probe... to add an excitation to the port. One should be able to see each excitation in
the project manager tree.
74
7. Once all ports are excited, create your analysis set up. Right click analysis in the
project manager and select Add Planar EM Solution Setup.
8. In the PlanarEM Setup window, input your solution frequency and check use edge
mesh.
9. At the next window, add your frequency sweep. Select Discrete. Input a sweep starting
from 1.5 GHz to 3.5 GHz in 0.05 GHz steps and select update.
75
10. Simulate your design by right clicking analysis in the project manager and selecting
analyze or simply press F10.
11. When the simulation is complete, right click results > create standard report >
rectangular plot.
76
12. From this window, we can choose to plot the S-Parameters and even the phase by
plotting the angle. In this case, we are plotting S11, S12, S13, an S14 in dB.
5. Simulation Results:
77
6. Conclusion: The first plot shows the S-Parameters using Port 1 as an input. As the
reader can see, S12 and S13 shows -3.4 dB at 2.4 GHz which is close to an equal or -3 dB
split. Plotting the angle of S12 and S13, we can see that the two outputs are in phase.
Similarly, if we choose port 2 as an input, the output at port 1 and port 4 are about 185
out of phase which is close to a 180 shift. With this we can see that the 180 hybrid or
rat-race hybrid works according to theory. The reader can verify that the results are close
to the ideal matrix by plotting each s-parameter in the scattering matrix. The shifts or
extra loss in simulation are to be expected because the rat-race hybrid was designed on a
lossy material, vias with coaxial excitation were also used to simulate the design which
are also lossy compared to edge ports which are ideal excitations but not realistic.
78
79
Bandwidth: The bandwidth of the filter is the cutoff frequencies (high and low) of the
filter. For example, a filter centered at 2.5 GHz with a 0.2 FBW (filter bandwidth) would
have a low cutoff frequency of 2.25 GHz and upper cutoff frequency of 2.75 GHz, where:
FBW
high low
center
(1)
Source and Load Response: This is the input and output impedance. This is usually
50, and in our lab we will use 50.
Dielectric Constant: This is the permittivity of the substrate. Dielectric constant is
denoted by r.
Substrate Height: Height of the substrate, or substrate thickness.
Conductor Thickness: This is the thickness of the copper on top of the substrate. In the
layers tab this is called the signal layer. Typically the weight in oz will denote the
conductor thickness.
Cover Height: Cover height is the height of a second conductor that would be on top of
the conductor or signal plane.
At this point you have entered your data for the filter design. Next you can get the
specifications for the physical dimensions from Ansoft Designer. You can either read the
table or right click on each strip.
Width: Width is abbreviated as w1, w2, w3, etc. These are the widths of the coupled
sections. The coupled sections are shown below as length 1.
Spacing: Spacing is abbreviated as S1, S2, S3, etc. This is the spacing of each quarter
wavelength microstrip coupled section.
Length: Length is abbreviated as P1, P2, P3, etc. This is the length of each half
wavelength strip.
80
(2)
(3)
You may notice that the length of the line may not be exactly half wavelength long. Due
to the End-Effect Capacitance, capacitively coupled resonators appear slightly longer,
called excessive phase length. If the length is not adjusted while designing a quarter
wave resonator, the center frequency will shift. Their lengths are adjusted to compensate
for this phenomenon. The half wave resonators are made slightly shorter by l:
lj
re j ro
1
2
l j
(4)
These microstrip band pass filters have a limited bandwidth of up to 15%. It is possible
to increase the bandwidth by using a few advanced techniques. The impedance of the
resonators may be increased. The first resonator may be externally coupled by tapping
instead of using a coupler section. Raising the termination resistance presented to the
filter by using quarter-wave impedance transformer sections for the input and output
leaders. All these techniques cause the couple distance to increase. It is possible to
increase the bandwidth to as high as 40%.
81
3. Ansoft Designer Simulation: Ansoft Designer SV is a tool for applying basic circuit
theories and techniques for developing high-frequency engineering applications. It
provides circuit simulation for radio frequency (RF) and microwave hardware
development. Ansoft Designer SV contains a complete high-frequency linear circuit
simulator, schematic and layout design entry, planar electromagnetic solver, design
utilities, and post-processing, all integrated in a common environment. It is able to create
and simulate hierarchical circuit designs for RF and microwave applications, such as
filters, small-signal amplifiers, matching networks, power splitters and combiners, and
couplers. It includes real-time tuning, filter and TRL synthesis, as well as plots and data
tables.
First, run Ansoft Designer software. Go into Project Insert Filter Design.
The window below will open. Choose type of filter, topology, approximation, and
prototype. For our experiment, we choose band pass, edge coupled, maximally flat,
microstrip. The design model will be created. Then click on the Next button.
82
In this window, put in values for order, frequency, and bandwidth for design
requirements. Our values are 3, 2.5 GHz, and 0.5 for 50% bandwidth. Click on the
Narrowband button to get close-up plot with frequency range in this case from 2 to 3
GHz. Then click on the Next button.
The following window lets you input values for substrate constant, height, and conductor
thickness. Our values are 1.06, 3.2, and 0.036 mm. The values for design dimensions are
shown below on the left side of the schematic, these are important measurements for the
actual fabrication later on. Click on Next.
83
On the next window, the impedances of each microstrip transmission line are calculated
and displayed. Click on Finish and our Filter Design Wizard step is done.
After clicking on Finish, you should see something like the following. Click on Export
Physical Circuit button on the toolbar where the red arrow is pointing.
84
Next, select the entire schematic layout and copy to Planar EM where we can make
changes. To do this, go to Edit Copy to Planar EM. To be able to add the 50 Ohm
transmission lines to the ends of the filter below, the ports where the red circles are have
to be removed. Select the ports and right-click to access the menu to delete them.
Click on the Draw rectangle button on the toolbar to draw. The dimensions of the 50
Ohm lines are calculated using Planar EM Estimate feature. Choose the length of
the 50 Ohm lines to be a quarter wavelength.
85
The 50 Ohm lines have to be connected to the ends of the filter. To do this, go to Layout
Merge Polygons Union.
Then add ports as the ends of the 50 Ohm lines by clicking on the Select edges button on
the toolbar.
86
This has to be done one at a time. When the edge is selected, draw port by clicking on
the button Draw Port.
Click on the Set Up Mesh button on the toolbar to get the following window. Set
frequency to the filters center frequency and check on Use Edge Mesh.
87
88
If the layout looks like below, you have a good overlay. You can tell by looking at where
the lines are union. If you have too many lines of the pattern close to each other, it means
theres a bad union being done and it will affect the final result.
With mesh overlay checked, we are now going to set up the Frequency Sweeps by
clicking on the following button.
Check on the linear step radio button, set start, stop, and frequency step then click on the
Update button. The smaller step you set, the more accurate the results. Click on the OK
button to exit.
89
Next, click on the Analyze button on the toolbar to start the simulation. This is what the
button looks like.
On the bottom right corner, you should see the simulation running as below. Wait for it
to be done, this will take a while depending on how big the frequency step is.
90
These two figures below are our simulation results. From looking at the figures, our
bandwidth seems to be between 2.2 and 2.55 GHz where both conditions are met which
91
are transmission loss is 3 dB or less and return loss is around 10 dB. The best match we
have is about 44 dB at a frequency of 2.43 GHz.
XY Plot 1
Ansoft Corporation
EM_Export_Filter12
0.00
Curve Info
m1
dB(S(Port1,Port2))
Setup 1 : Sw eep 2
m2
-5.00
dB(S(Port2,Port1))
Setup 1 : Sw eep 2
dB(S(Port1,Port1))
Setup 1 : Sw eep 2
-10.00
dB(S(Port2,Port2))
Setup 1 : Sw eep 2
Y1
-15.00
-20.00
-25.00
-30.00
-35.00
Name
m1
2.1800
-2.9844
m2
2.6000
-3.5207
-40.00
2.00
2.10
2.20
2.30
2.40
2.50
F [GHz]
2.60
2.70
2.80
2.90
3.00
Ansoft Corporation
EM_Export_Filter12
0.00
Curve Info
dB(S(Port1,Port2))
Setup 1 : Sw eep 2
-5.00
dB(S(Port2,Port1))
Setup 1 : Sw eep 2
dB(S(Port1,Port1))
Setup 1 : Sw eep 2
-10.00
dB(S(Port2,Port2))
Setup 1 : Sw eep 2
Y1
-15.00
m2
-20.00
m1
-25.00
-30.00
Name
m1
2.2600
-23.5407
m2
2.4000
-19.7359
m3
2.4600
-28.5240
m3
-35.00
-40.00
2.00
2.10
2.20
2.30
2.40
2.50
F [GHz]
2.60
2.70
2.80
2.90
3.00
92
4. Conclusion: This lab is a useful exercise for us to learn how to design a microwave
band pass filter. In this design, from the network analyzer calibration on the fabricated
coupled band pass filter, the reflection coefficient S11, we have low reflection. It is 45
dB and 2.4372 GHz at the center, therefore, the matching is good. There is a little power
reflected back to port one at marker 3. The best matching relative approximate 45dB
matching requirement range frequency from 2.225 GHz and 2.4372 GHz. On the
insertion loss S12, the loss due to transmission in the pass band is very close to zero.
Where the power is close to 1.5 dB on either side of the center the frequencies is the
cutoff frequency. S12 is the same as S21, then marker 1 and 2 are close to 1.5 dB and
these two points make the bandwidth of the filter. The bandwidth of the filter is 0.337
GHz.
93
94
Appendix: Instruction
Transformer
Help
for
Designing
Multi-Stage
Determine the effect of using multi-stage transformers (Chebyshev and Binomial) vs.
quarter-wave transformers/no matching transformer. Use FR-4 substrate of 30 mil
thickness. The frequency of operation is 5 GHz.
1. Open Ansoft Designer and select Project > Insert Circuit Design.
95
3. Switch to the components tab in the project manager, and expand the Distributed folder
to get to the microstrip components.
4. Drag and drop a Microstrip transmission line, physical length (expand Microstrip
folder) onto the modeling area.
96
6. Z0 is the characteristic impedance of the line and E is the electrical length in degrees.
Insert the frequency of operation and synthesize the dimensions. Select place and ok.
7. Under Resistors, place a resistor onto the circuit model. Edit as necessary.
97
98
11. By modifying the circuit, plot figures with no matching transformer (50 Line ->
200 load), a single stage matching transformer (quarter-wave transformer), up to 4
stages (multi-stage transformer - both Chebyshev and binomial). Determine
characteristics/improvement through simulation and compare results for each case.
Compare matching bandwidth with -10 dB matching criterion (VSWR 2:1).
99
No Matching Transformer
Circuit1
ANSOFT
-4.50
-4.55
Curve Info
-4.65
dB(S(Port1,Port1))
LinearFrequency
dB(S(Port1,Port1))
-4.60
-4.70
-4.75
-4.80
-4.85
-4.90
-4.95
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
F [GHz]
100
10.00
Bibliography
1.
2.
3.
4.
101