Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

ETPG-275.pdf 250 KVA Perkins PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

POWERED BY PERKINS

DIESEL GENERATOR SET

Model: ETPG275
INDUSTRIAL RANGE
Powered by Perkins

Generating Rates
PRIME

STANDBY

kVA

250

275

kW

200

220

POWER RATING
POWER
Rated Speed

r.p.m

1500

Standard Voltage

400

Available Voltages

400/230 - 230/132 - 230 V

Cos Phi

0.8

Rated at power factor

Ambient conditions of reference: 1000 mbar, 25C, 30% relative humidity. Power according to ISO 3046
normative.
P.R.P. Prime Power - ISO 8528 : prime power is the maximum power available during a variable power
sequence, which may be run for an unlimited number of hours per year,between stated maintenance intervals.
The permissible average power output during a 24 hours period shall not exceed 80% of the prime power. 10%
overload available forgoverning purposes only.

Standby Power (ISO 3046 Fuel Stop power): power available for use at variable loads for limited annual time
(500h), within the following limits of maximum operating time: 100% load 25h per year 90% load 200h per
year. No overload available. Applicable in case of failure of the main in areas of reliable electrical network.

POWERED BY PERKINS
DIESEL GENERATOR SET

Diesel Generating Sets

Model: ETPG275
INDUSTRIAL RANGE
Powered by Perkins

Engine Specifications 1500 r.p.m.


ENGINE
Rated Output

PRP

STANDBY

217

239

kW

Manufacturer

Perkins

Model

1306C-E87TAG6

No. of Cylindirs and Build

4 Cycle; In-line;6 Cylinder Diesel


Turbocharged air-to-air
charge cooled
116.6X135.9

Aspiration and Cooling


Bore/Stroke

mm

Compress the ratio

16.9:1

Cooling system

Water-cooled

Engine Speed/Frequency
Coolant Capacity

rpm/Hz 1500/50HZ
37.2
L

Starting System

Electric 24 volt DC

Displacement

8.7

Lubricant system Capacity

26.4

Battery Volatge / Capacity

24VDC

Governing Type

Type

Air Filter

Type

Fuel Consumption

Electronic
Dry

Load

100%

75%

50%

25%

L/h

45.0

36.0

24.0

13.8

ENGINE--Industrial 4 stroke cooled diesel engine complete with air,fuel and oil filters,electric
starting and charging equipment,engine protection against low water level.
COOLING--Radiator and colling fan complete with protection guards,designed to cool engine at
specified output in air temperatures upto 45 ,radiators suitable for higher temperatures are
available.Low water level protection fitted as standard.
ELECTRICAL SYSTEM--24V upto.Axial type starter motor,battery charging alternator,high capacity
lead acid battery,and battery tray mounted on the generator base frame,and heavy duty
interconnecting cable with terminations.
EXHAUST SYSTEM--Heavy duty industrial exhauset silencer with flexible piping.

POWERED BY PERKINS
DIESEL GENERATOR SET

Diesel Generating Sets

Model: ETPG275
INDUSTRIAL RANGE
Powered by Perkins

Alternator Technical Specifications


ALTERNATOR BRAND

LEROY SOMER

STAMFORD

LSA46.2L6

UCI274K

Model
Exciter System
Poles

Self-excited, brushless
Num

Cooling Fan

Cast alloy aluminum

Bearing

Single,double shielded

Windings

100% copper

Connection Type

Reconnectable

Insulation Type

Class

Class H

Pitch

2/3

Amortisseur Winding

Full

Voltage Regulator

A.V.R. (Electronic)

Steady Voltage Precision

1%

Underspeed Protection

Standard

Overexcitation Protection

IP23

TIF (1960 Weightings)

<50

ALTERNATOR--Brushless,self exciting,self regulation,sreen protected,drip proof rated in


accordance with IEC60034.Voltage regulation maintainted within 0.5% from no load to full
load.between 0.8 lagging and unity.All standard voltages available.

POWERED BY PERKINS
DIESEL GENERATOR SET

Model: ETPG275

Diesel Generating Sets

INDUSTRIAL RANGE
Powered by Perkins

Control Panel Technical Specifications


Control Panel- SMARTGEN 6110/6120
The base mounted control panel in a vibration isolated sheet steel enclosure.The control panel is
equipped as follows:
a)Instruments:Analogue Volmeter,Hours Run Meter.Water pressure Meter.
b) Controls:Emergency Stop Pushbutton,Volmeter Phase Selector Switch.
c) Control module:Standard collocation is smartgen Auto start with AMF.

Main Features:
Automatic mains failure
Engine control,Generator protection
Built in alarms and warnings
Remote Start operation available
Fuel pump control
Mains simulation
Block heater control
Field adjustable parameters
Free MS-Windows Remote monitoring
LED displays
Configurable analogue inputs
I/O expansion capability

Protection Circuits

Instruments

WARNING

ENGINE

Battery charge failure

Engine speed

Low battery voltage

Oil pressure

SHUT DOWNS

Coolant temperature

Fail to start

Run time

Emergency stop

Battery volts

Low oil pressure

TOR

High engine temperature

Voltage (L-N)

Over /Under speed

Current (L1-L2-L3)

Under/over generator frequency

Frequency

Failed to reach loading voltage

Mains

Electrical trip

Voltage (L-L, L-N)

Generator over current

POWERED BY PERKINS
DIESEL GENERATOR SET

Diesel Generating Sets

Model: ETPG275
INDUSTRIAL RANGE
Powered by Perkins

Generating Sets Standard Features


Three phase four wire,output voltage 400V/230V,50HZ,between 0.8 lagging,protection capability
according with the standard of NAME1 and IP23.

General Features:
Composed of Perkins diesel engine and Stamford or Leroy somer alternator
Oil and fuel filter fitted,water separator
Lube-oil drain valve fitted
Electric Starter Charge motor 24 VD.C
Water-cooled
8-hours operation base tank
Auto start
Optional soundproof and weatherproof canopy
3 pole MCCB Delixi breaker
Operation & Maintenance manual
Special Integrated Steel Base tank and sprayed overall in gloss enamel paint

Voltage Regulation:
Voltage regulation maintanined within 0.5%
Between 0.8 and 1.0 lagging and unity
From no load to full load
At speed droop variation upto 4.5%

Frequency Adjustable Ratio:


Change load from 0-100%,within 1.0%( electric speed regulator),within 4.5%( mechanical speed
regulator)

Frequency Undulation:
load from 0-100%,frequency undulation within 0.25%
No load wire volts max undulation ration\ within 1.8%
Three Phrase balanced load in the order of 5%
Effect factor of Telecom
TIF better than 50
THF to IEC60034 Part 40 better than 2%

POWERED BY PERKINS
DIESEL GENERATOR SET

Diesel Generating Sets

Model: ETPG275
INDUSTRIAL RANGE
Powered by Perkins

Soundproofed Version Features

Robust Corrosion Resustant Construction


Black finish stainless stell lock and hinges
Body made from steelcomponents treated with polyester powder coating

Excellent Access for Maintenance


Two large doors on each side
Radiator fill access plate
lube oil and cooling water drains pipes to exterior of the enclosure

Security and Safety


Control panel viewing window in a lockable access door
Emergency stop push buttom (red)mounted on enclosure interior
Cooling fan and battery charging alternator fully guarded
Exhaust silencing system totally enclosed for operator safely

POWERED BY PERKINS
DIESEL GENERATOR SET

Diesel Generating Sets

Model: ETPG275
INDUSTRIAL RANGE
Powered by Perkins

Generating Sets other Features


Generating Sets Optional Features
Low fuel level alarm shutdown
Automatic Fuel Filling System
Engine oil feeding and drain pump
Auto Transfter Switch( ATS)
Parallel control panels
Circuit Breaker MCCB & ACB
Remote Control Panel
weatherproof/soundproof Canopy
Trailer type Gensets

Quality Standards
ISO9001:2000,ISO14000,ISO3046
ISO8528 BS4999
BS5514,AS1359,ICE34
CE Compliance

Gensets Dimensions & Weight


Open type:LxWxH (mm) / Net Weight Kgs
3035*900*1525 / 2035
Silence type:LxWxH (mm) / Net Weight Kgs
3930*1130*2200/ 3080

You might also like