Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ultradryer Hre

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Te c h n i c a l D a t a

Adsorption Dryer HRE

HRE

Vnom at 7 bar(g)

connections
PN16, DIN 2633

installed
power

dimensions
weight

A=width

B=depth

m3/h

cfm

DN

kW

kg

mm

mm

C=hight
mm

0375

375

220

DN 50

7,6

710

1430

800

2120

0550

550

325

DN 50

11,2

920

1510

985

2340

0650

650

385

DN 50

11,2

1050

1530

985

2260

0850

850

500

DN 50

14,2

1140

1590

1060

2330

1000

1000

590

DN 80

14,2

1210

1660

1120

2460

1350

1350

800

DN 80

20,0

1480

1770

1190

2580

1650

1650

975

DN 80

24,0

1790

1800

1340

2630

1950

1950

1150

DN 100

32,5

2180

2040

1400

2720

2250

2250

1330

DN 100

32,5

2360

2110

1410

2740

2750

2750

1620

DN 100

38,0

2680

2260

1460

2790

3500

3500

2065

DN 100

44,5

3180

3380

1830

2860

4000

4000

2360

DN 150

52,5

3990

3490

1860

2980

5000

5000

2945

DN 150

71,0

4820

3750

1950

3110

6000

6000

3535

DN 150

86,0

5400

3880

2170

3210

7000

7000

4125

DN 150

95,0

6200

4240

2270

3280

8750

8750

5155

DN 200

115,0

8000

4570

2530

3420

10500

10500

6185

DN 200

135,0

11200

4780

2600

3310

11200

11200

6775

DN 200

153,0

12000

4970

2750

3350

13600

13600

8010

DN 200

177,5

14000

5280

2975

3380

nom in m3/h related to compressor inlet at 20C and 1 bar(a), an operating pressure of 7 bar(g) and a compressed air inlet
V
temperature of +35C (saturated).
up to 2750

operating pressure bar(g)


4

10

30

0,72 0,92 1,09 1,25 1,36 1,45 1,51

35

0,55 0,7 0,86 1,00 1,12 1,25 1,37

40

0,33 0,45 0,58 0,71 0,82 0,92 1,03


table 2

Sizing Example:
real air ow (V
T):
operating pressure:
inlet temperature:
Faktor C1:

corr=
V

T
V
C1

Selection:

from 3500

3990 m/h
6 bar(g)
40 C
0,58

Tinlet

Conversion factor (C1) for sizing, depending on


dryer inlet temperature and operating pressure at
a pressure dew point of -40C:

3990 m3/h
= 6879 m/h
0,58
HRE 7000

Technical changes reserved. Release: R01/31082004


Donaldson Filtration Deutschland GmbH Bssingstrasse 1 D-42781 Haan Tel: ++49-2129-569-0 Fax: ++49-2129-569-100

Te c h n i c a l D a t a

Adsorption Dryer HRE


1. Process Characteristics
Desorption in counterow to the adsorption direction
Cooling with an expanded portion of compressed air
Designed for automatic and continuous operation

2. Standard Conditions
Pressure dewpoint:
Operation pressure:
Inlet temperature:
Inlet humidity:
Average cooling air consumption:

-40C
7 bar(g)
+35C
saturated
nom
appr. 2% related to V

Selection at different operating


conditions by correction factor
C1 according to table 2.

compressed air/nitrogen
4-10 bar(g)
5-40C
5-40C
35C/45% to 30C/60% r.H.
indoor

Design for operating conditions


beyond specified application
limits on request.

3. Operating Limits
Media:
Operating pressure:
Inlet temperature
Ambient temperature:
max. blower inlet:
Installation:

4. Standard Design
Control
Design:
Power supply:
Control voltage:
PLC:
Text display:
Protection:
Control panel:
Potential free common alarm contact:
Main switch:
Adsorption Vessel
Material:
Design data:
Design, manufacturing and testing:
Approval:
Desiccant:
gas distributor:

acc. to VDE/IEC
3 Ph / 400 V - 50 Hz
24 V DC / 230 V - 50 Hz
Siemens S7-200 with CPU 224
Siemens TD 200
IP 55, acc. to IEC 529
C-steel sheet, powder coated, RAL7035
incl.
incl.

carbon steel
11 bar(g), 230C fr 0375 - 2750
10 bar(g), 200C fr 3500 - 13600
acc. to AD-2000
acc. to PED 27/23/EC
incl.
incl. (stainless steel)

Piping
Nominal pressure:
Material:
Design, manufacturing and testing:
Approval:

PN 16
carbon steel
acc. to AD-2000
acc. to PED 27/23/EC

Heat insulation
Electrical ange heater
Regeneration blower

heater to regeneration inlet valves


with overheat protection
with suction lter
Technical changes reserved. Release: R01/31082004

Donaldson Filtration Deutschland GmbH Bssingstrasse 1 D-42781 Haan Tel: ++49-2129-569-0 Fax: ++49-2129-569-100

Te c h n i c a l D a t a

Adsorption dryer HRE


continuation of standard design
Pneumatically operated buttery valves
Non-return valves
Pressure release valves
Pressure equalization valves
Resistance thermometer
Pressure transmitter
Manometer with shut-off valve
Control air unit
Pneumatic box
End position monitoring
Control air piping

internals made of stainless steel


with PTFE- gaskets
with silencers
incl.
Pt 100 - measuring and control devices
for pressure and changeover control
per adsorption vessel
incl. valve manifold with multipole connection and control air lter
to house the control air unit (sizes 3500 and up)
of inlet buttery valves with limit switches (sizes 3500 and up)
up to size 2750 with PVC-pipe; with galvanized steel pipe (sizes
3500 and up)

5. Standard Options (upon request)


Dewpoint dependent control ultraconomy
Mounting of prelter system incl. piping
Mounting of afterlter system incl. piping
System bypass with 3 manual valves
Bus interface
Desorption air heating with steam heater instead of electrical heater
Desorption air heating with steam and electrical heater
Heat insulation of adsorption vessel
16 bar version
Status information by light indicators
Control air piping made of stainless steel
Changeover monitoring and limit switches for additional buttery valves
Monitoring of dryer inlet temperature
Free of silicone / separating agents
Alternative power supply
Pressure dew point below -40C
Frost protection down to -20C
Outdoor installation
Special noise reduction

6. Filter
Please select the necessary prelter and afterlter systems from our comprehensive lter product range.

7. Condensate
For necessary and economical draining as well as conditioning of accumulated condensate, we recommend
our condensate technology range of products.

Technical changes reserved. Release: R01/31082004


Donaldson Filtration Deutschland GmbH Bssingstrasse 1 D-42781 Haan Tel: ++49-2129-569-0 Fax: ++49-2129-569-100

You might also like