Ultradryer Hre
Ultradryer Hre
Ultradryer Hre
HRE
Vnom at 7 bar(g)
connections
PN16, DIN 2633
installed
power
dimensions
weight
A=width
B=depth
m3/h
cfm
DN
kW
kg
mm
mm
C=hight
mm
0375
375
220
DN 50
7,6
710
1430
800
2120
0550
550
325
DN 50
11,2
920
1510
985
2340
0650
650
385
DN 50
11,2
1050
1530
985
2260
0850
850
500
DN 50
14,2
1140
1590
1060
2330
1000
1000
590
DN 80
14,2
1210
1660
1120
2460
1350
1350
800
DN 80
20,0
1480
1770
1190
2580
1650
1650
975
DN 80
24,0
1790
1800
1340
2630
1950
1950
1150
DN 100
32,5
2180
2040
1400
2720
2250
2250
1330
DN 100
32,5
2360
2110
1410
2740
2750
2750
1620
DN 100
38,0
2680
2260
1460
2790
3500
3500
2065
DN 100
44,5
3180
3380
1830
2860
4000
4000
2360
DN 150
52,5
3990
3490
1860
2980
5000
5000
2945
DN 150
71,0
4820
3750
1950
3110
6000
6000
3535
DN 150
86,0
5400
3880
2170
3210
7000
7000
4125
DN 150
95,0
6200
4240
2270
3280
8750
8750
5155
DN 200
115,0
8000
4570
2530
3420
10500
10500
6185
DN 200
135,0
11200
4780
2600
3310
11200
11200
6775
DN 200
153,0
12000
4970
2750
3350
13600
13600
8010
DN 200
177,5
14000
5280
2975
3380
nom in m3/h related to compressor inlet at 20C and 1 bar(a), an operating pressure of 7 bar(g) and a compressed air inlet
V
temperature of +35C (saturated).
up to 2750
10
30
35
40
Sizing Example:
real air ow (V
T):
operating pressure:
inlet temperature:
Faktor C1:
corr=
V
T
V
C1
Selection:
from 3500
3990 m/h
6 bar(g)
40 C
0,58
Tinlet
3990 m3/h
= 6879 m/h
0,58
HRE 7000
Te c h n i c a l D a t a
2. Standard Conditions
Pressure dewpoint:
Operation pressure:
Inlet temperature:
Inlet humidity:
Average cooling air consumption:
-40C
7 bar(g)
+35C
saturated
nom
appr. 2% related to V
compressed air/nitrogen
4-10 bar(g)
5-40C
5-40C
35C/45% to 30C/60% r.H.
indoor
3. Operating Limits
Media:
Operating pressure:
Inlet temperature
Ambient temperature:
max. blower inlet:
Installation:
4. Standard Design
Control
Design:
Power supply:
Control voltage:
PLC:
Text display:
Protection:
Control panel:
Potential free common alarm contact:
Main switch:
Adsorption Vessel
Material:
Design data:
Design, manufacturing and testing:
Approval:
Desiccant:
gas distributor:
acc. to VDE/IEC
3 Ph / 400 V - 50 Hz
24 V DC / 230 V - 50 Hz
Siemens S7-200 with CPU 224
Siemens TD 200
IP 55, acc. to IEC 529
C-steel sheet, powder coated, RAL7035
incl.
incl.
carbon steel
11 bar(g), 230C fr 0375 - 2750
10 bar(g), 200C fr 3500 - 13600
acc. to AD-2000
acc. to PED 27/23/EC
incl.
incl. (stainless steel)
Piping
Nominal pressure:
Material:
Design, manufacturing and testing:
Approval:
PN 16
carbon steel
acc. to AD-2000
acc. to PED 27/23/EC
Heat insulation
Electrical ange heater
Regeneration blower
Donaldson Filtration Deutschland GmbH Bssingstrasse 1 D-42781 Haan Tel: ++49-2129-569-0 Fax: ++49-2129-569-100
Te c h n i c a l D a t a
6. Filter
Please select the necessary prelter and afterlter systems from our comprehensive lter product range.
7. Condensate
For necessary and economical draining as well as conditioning of accumulated condensate, we recommend
our condensate technology range of products.