Mechatronics Lab Manuaol 2
Mechatronics Lab Manuaol 2
Mechatronics Lab Manuaol 2
EXP NO:1
DATE:
AIM:
To study about the important features, about Mechatronics system.
INTRODUCTION TO MECHATRONICS SYSTEM:
Mechatronics is one of the new and existing fields on the engineering
landscape, subsuming parts of traditional engineering fields and requiring a
broader approach to the design of system that we can formally call as Mechatronics
system.
Many industries improving their works through automation which is based
on the inter connection between the electronic control systems and mechanical
engineering.
Such control systems generally use microprocessors as controllers and have
electrical sensors extracting information from mechanical inputs through electrical
actuators to mechanical systems.
This can be considered to be application of computer based digital control
techniques through electronic and electric interfaces to mechanical engineering
problems. Successful design of Mechatronics can lead to products that are
extremely attractive to customer in quality cost-effectiveness.
MECHATRONICS DEFINITION:
Mechatronics may be defined as a multi-disciplinary field of study that
implies the synergistic integration of electronic engineering, electric engineering,
control engineering and computer technology with mechanical engineering for the
design, manufacture, analysis and maintenance of a wide range of engineering
products and processes.
Valves:
Valves are refitted in the system to control liquid direction, pressure, and
flow rate.
Actuator:
An actuator is provided to convert the liquid energy into mechanical
force or torque to do useful work. The actuator is the actual working element of
the system. The actuators can be either cylinders (to provide linear motion) or
hydro motors (to provide rotary motion).
Fluid-transfer piping:
The hydraulic Piping is provided to carry the compressed liquid from one
place to another.
Description
LINES
-continuous line flow line
-dashed line - pilot, drain
-envelope - long and short dashes around two or
more component symbols
CIRCULAR
-large circle - pump, motor
-small circle - Measuring devices
-semi-circle rotary actuator
SQUARE
-one square - pressure control function
Description
MOTORS
Fixed Displacement Hydraulic Motor
-unidirectional
-bidirectional
Variable Displacement Hydraulic Motor
-unidirectional
-bidirectional
Pneumatic Motor
-unidirectional
-bidirectional
Rotary Actuator
-hydraulic
-pneumatic
CYLINDERS
Single Acting Cylinder
Description
DIRECTIONAL CONTROLVALVES
Directional Control Valve (2 Ports / 2Positions)
-Normally closed directional control valve with 2
ports and 2 finite positions.
-Normally open directional control valve with 2
ports and 2 finite positions.
Directional Control Valve (3 Ports / 2Positions)
-Normally closed directional control valve with 3
ports and 2 finite positions.
-Normally open directional control valve with 3
ports and 2 finite positions.
Directional Control Valve (4 Ports / 2Positions)
-directional control valve with 4 ports and 2 finite
positions
Directional Control Valve (4 Ports / 3Positions)
-directional control valve with 4 ports and 3 finite
positions
*-(center position can have various flow paths)
Directional Control Valve (5 Ports / 2 Positions) Normally A Pneumatic Valve
-directional control valve with 5 ports and 2 finite
positions
Directional Control Valve (5 Ports / 3 Positions) Normally A Pneumatic Valve
Description
-roller
-roller(one direction only)
Electrical Control
-Solenoid (the one winding)
Pilot Operation
-pneumatic
-hydraulic
Pilot Operated Two-Stage Valve
-Pneumatic: Sol first stage
-Pneumatic: Air pilot second stage
-Hydraulic: Sol first stage
-Hydraulic: Hydraulic pilot second stage
part of circuit
Rapid Exhaust Valve/Pneumatic
-installed close to an actuator for rapid movement
of the actuator
PRESSURE CONTROLVALVES
Pressure Relief Valve(Safety Valve) Normally Closed
- Line pressure is limited to the setting of the valve,
secondary part is directed to tank
Symbols
Description
10
FLOW CONTROLVALVES
Throttle valve
-adjustable output flow
Flow Control Valve
-with fixed output (variations in inlet pressure do
not affect rate of flow)
-with fixed output and relief port to reservoir with
relief for excess flow (variations in inlet pressure do
not affect rate of flow)
-with variable output
-fixed orifice
-metered flow toward right free flow to left
-pressure compensated flow control fixed output
flow regardless of load
-pressure and temperature compensated
-with variable output and relief port to reservoir
Flow Dividing Valve
-flow is divided equally to two outputs
SHUT-OFFVALVE
-Simplified symbol
Symbols
Description
Lubricator
-oil vapor is indicted into airline
Conditioning unit
-compound symbol of filter, regulator, lubricator unit
-Simplified Symbol
RESULT:
Thus the important feature Mechatronics system was studied.
12
NORMAL POSITION
13
DATE:
AIM:
To operate a single acting cylinder using the Directional Control Valve (DCV)
in Pneumatic Trainer Kit.
APPARATUSREQUIRED:
FLUIDSIM(P) Software
Single Acting Cylinder
3/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
14
ACTUATED POSITION
15
RESULT:
Thus the single acting cylinder was operated using DCV in Pneumatic
Trainer Kit.
NORMAL POSITION
16
DATE:
AIM:
17
To operate a single acting cylinder using the Directional Control Valve (DCV)
in Pneumatic Trainer Kit.
APPARATUSREQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
4/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder
ACTUATED POSITION
18
19
RESULT:
Thus the double acting cylinder was operated using DCV in Pneumatic
Trainer Kit.
NORMAL POSITION
20
21
DATE:
AIM:
To operate a double acting cylinder using AND logic circuit in Pneumatic
Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
4/2 Pilot Operated DCV
3/2 Hand Levered DCV
Two Pressure Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
22
ACTUATED POSITION
23
RESULT:
Thus the double acting cylinder using AND logic circuit was operated
in Pneumatic Trainer Kit.
24
NORMAL POSITION
25
DATE:
AIM:
To operate a double acting cylinder using OR logic circuit in Pneumatic
Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
4/2 Pilot Operated DCV
3/2 Hand Levered DCV
Shuttle Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
26
ACTUATED POSITION
27
RESULT:
Thus the double acting cylinder using OR logic circuit was operated
in Pneumatic Trainer Kit.
NORMAL POSITION
28
29
DATE:
AIM:
To operate a single cycle automation of multiple cylinders in cascading
+ + - method (A B B A ) in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
3/2 Push Button Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
30
ACTUATED POSITION
31
RESULT:
Thus the single cycle automation of multiple cylinders was operated
+
NORMAL POSITION
32
DATE:
33
AIM:
To operate a single acting cylinder using an impulse pilot valve in
Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Single Acting Cylinder
3/2 Hand Levered Spring Return DCV
3/2 Pilot Operated Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
34
35
RESULT:
Thus the single acting cylinder was operated using an impulse pilot valve
in Pneumatic Trainer Kit.
NORMAL POSITION
36
DATE:
AIM:
To control the speed of double acting cylinder using Metering In valve
circuit in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Flow Control Valve
4/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
37
ACTUATED POSITION
38
39
RESULT:
Thus the speed of double acting cylinder was controlled using Metering In
valve circuit in Pneumatic Trainer Kit.
NORMAL POSITION
40
EXP NO: 2h
DATE:
AIM:
To control the speed of double acting cylinder using Metering Out valve
circuit in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Flow Control Valve
4/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
42
43
RESULT:
Thus the speed of double acting cylinder was controlled using Metering Out
valve circuit in Pneumatic Trainer Kit.
NORMAL POSITION
44
DATE:
45
AIM:
To operate automatic operation of a double acting cylinder in a single cycle
using limit switch in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
46
47
RESULT:
Thus the single cycle automation of double acting cylinder was operated by
using limit switch in Pneumatic Trainer Kit.
NORMAL POSITION
48
DATE:
49
AIM:
To operate automatic operation of a double acting cylinder in a multi cycle
using limit switch in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
50
51
RESULT:
Thus the multi cycle automation of double acting cylinder was operated by
using limit switch in Pneumatic Trainer Kit.
NORMAL POSITION
52
DATE:
53
AIM:
To operate the Single Cycle Automation of Multiple Cylinders in Sequence
(A+ B+ A-B-) in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
3/2 Push Button Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
54
55
RESULT:
Thus the single cycle automation of multiple cylinders was operated
+
NORMAL POSITION
56
EXP NO: 3a
DATE:
AIM:
To operate a single acting cylinder using the single solenoid valve in Electro
Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Single Acting Cylinder
Input / Output Relay Box
3/2 Solenoid Operated Spring Return Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
58
59
RESULT:
Thus the single acting cylinder was operated using single solenoid valve
in Electro Pneumatic Trainer Kit
NORMAL POSITION
60
DATE:
61
AIM:
To operate a double acting cylinder using the single solenoid valve in
Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM (P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated Spring Return Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
62
63
RESULT:
Thus the double acting cylinder was operated using single solenoid valve
in Electro Pneumatic Trainer Kit.
NORMAL POSITION
64
EXP NO: 3c
DATE:
AIM:
To operate a single acting cylinder using the double solenoid valve in
Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM (P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
66
67
RESULT:
Thus the double acting cylinder was operated using double solenoid
valve in Electro Pneumatic Trainer Kit.
NORMAL POSITION
68
DATE:
AIM:
69
ACTUATED POSITION
70
71
RESULT:
Thus the single cycle automation of double acting cylinder was operated
by using electrical switch in Electro Pneumatic Trainer Kit.
NORMAL POSITION
72
DATE:
73
AIM:
To operate the Single Cycle Automation of Multiple Cylinders in sequence
(A B B-A-) in Electro Pneumatic Trainer Kit.
+
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated DCV
Electrical Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
74
75
RESULT:
Thus the single cycle automation of multiple cylinders was operated
+
NORMAL POSITION
76
DATE:
77
AIM:
To operate automatic operation of a double acting cylinder in a multi cycle
using electrical switch in Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM (P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated DCV
Electrical Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
78
79
RESULT:
Thus the multi cycle automation of double acting cylinder was operated by
using electrical switch in Electro Pneumatic Trainer Kit.
NORMAL POSITION
80
81
EXP NO: 3e
DATE:
AIM:
To operate the Single Cycle Automation of Multiple Cylinders in sequence
(A B A-B-) in Electro Pneumatic Trainer Kit.
+
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated DCV
Electrical Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
82
83
RESULT:
Thus the single cycle automation of multiple cylinders was operated
+
84
85
EXP NO: 4a
DATE:
AIM:
To simulate the single acting cylinder with ON Delay Timer using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Sometimes delay the cylinder should be activated.
ACTUATED POSITION
86
87
RESULT:
Thus the actuation of single acting cylinder with ON Delay Timer was done
using PLC.
NORMAL POSITION
88
DATE:
89
AIM:
To simulate the single acting cylinder with OFF Delay Timer using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Sometimes delay the cylinder should be activated.
ACTUATED POSITION
90
91
RESULT:
Thus the actuation of single acting cylinder with OFF Delay Timer was
done using PLC.
NORMAL POSITION
92
DATE:
93
AIM:
To simulate the Operation of Single Acting Cylinder with AND Logic using
PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Sometimes delay the cylinder should be activated.
ACTUATED POSITION
94
95
RESULT:
Thus the single acting cylinder is actuated with AND logic using PLC
NORMAL POSITION
96
DATE:
97
AIM:
To simulate the Operation of Single Acting Cylinder with OR Logic using
PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Sometimes delay the cylinder should be activated.
ACTUATED POSITION
98
99
RESULT:
Thus the single acting cylinder is actuated with OR logic using PLC.
NORMAL POSITION
100
101
DATE:
AIM:
To simulate the Single Cycle Automation of Multiple Cylinders in sequence
(A B B-A-) using PLC
+
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Flow Control Valve
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the versa pro software in desktop.
Interface PLC with PC using RS232cable.
Write a ladder diagram.
Both Outputs of PLC (Q1, Q2, Q3 and Q4) are direct connecting to inputs
of solenoid coils.
Following the opening procedure of Codesys software.
Check the ladder diagram Sometimes delay the cylinder should be
102
activated.
ACTUATED POSITION
103
RESULT:
Thus the single cycle automation of multiple cylinders is operated in
+
105
EXP NO: 4f
DATE:
AIM:
To simulate the double acting cylinder with UP Counter Using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Double Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
.
ACTUATED POSITION
107
108
RESULT:
Thus the double acting cylinder is actuated with UP Counter using
PLC
NORMAL POSITION
109
DATE:
110
AIM:
To simulate the double acting cylinder with DOWN Counter Using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Double Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
ACTUATED POSITION
111
112
RESULT:
Thus the double acting cylinder is actuated with DOWN Counter
using PLC
NORMAL POSITION
113
DATE:
114
AIM:
To simulate the Automation sequence of Single Acting Cylinder Using PLC.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Observe the working of single acting cylinder is automatic reciprocating.
ACTUATED POSITION
115
116
RESULT:
Thus the automation of single acting cylinder is done by using PLC.
NORMAL POSITION
117
DATE:
118
AIM:
To simulate the Automation sequence of Double Acting Cylinder Using
PLC.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Double Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Observe the working of double acting cylinder is automatic reciprocating
ACTUATED POSITION
119
120
RESULT:
Thus the automation of double acting cylinder is done by using PLC.
NORMAL POSITION
121
122
DATE:
AIM:
To simulate the Single Cycle Automation of Multiple Cylinders in sequence
(A B A-B-) using PLC
+
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Flow Control Valve
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and 24V from PLC trainer to panel.
Open the versa pro software in desktop.
Interface PLC with PC using RS232cable.
Write a ladder diagram.
Both Outputs of PLC (Q1, Q2, Q3 and Q4) are direct connecting to inputs
of solenoid coils.
Following the opening procedure of Codesys software.
123
124
RESULT:
125
126
DATE:
AIM:
To operate a single acting cylinder using the Directional Control Valve (DCV)
in Hydraulic Trainer Kit.
APPARATUSREQUIRED:
FLUIDSIM (H) Software
Single Acting Cylinder
3/2 Solenoid DCV
Pump
PROCEDURE:
Draw the circuit in FLUIDSIM (H) software and check the connections.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage and correct it.
Open the valve and operate the cylinder.
127
ACTUATED POSITION
128
129
RESULT:
Thus the single acting cylinder was operated using DCV in Hydraulic
Trainer Kit
130