Actulux A/S Background and Visions


Actulux develops, produces and distributes innovative
electrical opening systems for skylights, windows and
smoke hatches.
Our visions are:
that our products are technological market leaders
with a very high performance.
that our products can be produced at an attractive
price level.
that our company is a strategically partner for our
customers
to have a significant size on the European market.

Actulux Europe organization and sales markets


Actulux representation with own organization:
Denmark technique/development, production, service, sales
Germany sales
Estonia / Baltics / Russia sales

Markets with continued sales (beyond the above):


Belgium
Finland
Estonia
Latvia
Lithuania
Switzerland
Austria
Norway
Sweden
UK
Belarus
Ukraine
Serbia
Slovenia
Holland
Portugal

Actulux Product Groups


Electrical Opening Systems
Traverse mounted:
SA Power Mini
70 - 110cm
SA Power Single
88 - 200 cm
SA Power Double
160 - 300 cm
SA Power Large
150 250 cm
Side mounted:
Chain motors 24V
Chain motors 230V (incl. remote control)
Rack & pinion motors

EN 12101-2 tested

Control Panels type SVM and SV

Control Panel SVM 24V 5 Amp


Control Panel SVM 24V 8 Amp
Control Panel SV 24V 24 Amp
Control Panel SV 24V 30 Amp
Control Panel SV 24V 32 Amp
Control Panel SV 48V 8 Amp
Control Panel SV 48V 24 Amp
Control Panel SV 48V 30 Amp
Control Panel SV 48V 32 Amp

Accessories

Fire switch
Comfort switch
Wind and rain sensor
Smoke / Heat detector
One week & 24h watch
Room thermostat
Remote control Unit
Etc.

EN 12101-10 certified

Actulux opening systems can be supplied with either 24 Volt or 48 Volt


Control Panels, 24V and 48V type SV(M) xx-xx-(DS) :
Product

Performance

Notes

Control Panels type SV(M) 24V


5 sizes: 5A, 8A, 24A, 30A, 32A

Incl. battery back-up


1 or 2 fire- and comfortgroups
Intelligent BUS-communication
Connection for fireswitches, detectors,
wind-/rainsencor, comfortswitch
Potential free failure and alarm output

EN12101-10
Certified
(class A= 2 x supply)

Control Panels type SV 48V


4 sizes: 8A, 24A, 30A, 32A

Benefits of using 48V:


The power consumption (amp.) to the opening systems
are reduced by 50%.
The thickness of the installation cables are reduced by 50% - 60%.
The control units can supply twice as many opening systems, which reduces the
total price for control units in medium and larger installations by 30-40%

Actulux Opening Systems


SA Power Single

Chain drives

(Patent rights)

Actulux Opening Systems in operation

SA Power Mini

SA Power Double
Rack & Pinion drives

SA Power Large

Actulux Control Panels


EN 12101-10 certificate
SVM Mini Control Panels

SV Control Panels

Control Panels
Volt / Ampere

RWA / Comf,
Groups

SVM 24V-5A-ds

24V / 5A

Yes

SVM 24V-8A-ds

24V / 8A

Yes

SV 24V-24A

24V / 24A

No

SV 24V-32A

24V / 32A

No

SV 48V-24A

48V / 24A

No

SV 48V-32A

48V / 32A

No

SV 24V-24A-ds

24V / 24A

Yes

SV 24V-30A-ds

24V / 30A

Yes

SV 24V-32A-ds

24V / 32A

Yes

SV 48V-8A-ds

48V / 8A

Yes

SV 48V-24A-ds

48V / 24A

Yes

SV 48V-30A-ds

48V / 30A

Yes

SV 48V-32A-ds

48V / 32A

Yes

Type

EN12101-10
Certified

Actulux Accessories

Actulux - Unique Selling Point


1. TECHNOLOGICAL LEADER

Performance and strength characterized Actulux products

Our partners/customers are seen as technological leaders (first movers) and can differentiate in their market with
design and quality.
Our customers and partners experience increased sales, both now and in the future.

2. ELECTRICAL OPENING SYSTEMS

100% focus on electrical solutions and developments

Extremely low current consumption and low installation costs.


Very low service and maintenance costs.
Unique product design with the lowest build-in-height in the market.
Silent operation with both smoke ventilation and natural ventilation, as standard, in the same product.
Electrical opening systems are the future technology, also in traditional pneumatic markets

3. THE CUSTOMER- AND MARKET STRATEGY OF ACTULUX


and development with our customers:

Know-how on high level, partnership

Technical know how on highest level and great experience with EN12101-2 tests - Actulux takes active part in the
work of the certifying process of our customers.
Constant product development and cost effectiveness in co-operation with our customers and partners with the
purpose of creating further growth.
Flexible with very short delivery time also for special solutions.

European norm EN 12101-2 regarding smoke ventilation (SHEV)


Annex A (Test procedure):
- Description of general test procedure, sequence, test reports, etc.
Annex B (CV factor aerodynamic area):
- Determination of CV factor, test method
- Demands for opening angles (f.ex. 90 for double flap and 140 or 160
for single flap
Annex C (Reliability and lifetime test):
- 10.000 comfort openings (f.ex. 15 sec. opening time ~ 30 Openingangle)
- Different classifications for full fire opening (f.ex. 50 or1000) within 60 sec.
Annex D (Snow load):
- 3 times full opening incl. snow load every opening within 60 sec.
- Different classifications (f.ex. 250, 500, 800 or 1000N/m2 )
Annex E (Low temperature):
- Define at which temperature snow load test has to be done
- Different classifications (f.ex. 0, -5, or -15C)
Annex F (Wind load):
- Define at which wind load (vacuum) the ventilator has to stay closed and afterwards be
able to open in full fire opening
- Different classifications (f.ex. 1500 N/m2)
Annex G (Heat):
- Define at which heat temperature the ventilator has to operate as smoke ventilator
- Different classifications (f.ex. 200, 300, or 600C)

Other relevant EN 12101 norm:


- 12101-9 (Control panels and fire switches etc. preliminary)
- 12101-10 (Power supply /energy source)

Electrical opening systems for smoke (EN12101-2)- and comfort ventilation


Product
SA-Mini

(Opening system for small single flap, 160)

SA Power Single

(Opening system for medium/large single flap,


up to165)

SA Power Double

(Opening system for medium/large double


flap, 2x90)

SA Power Large

(Opening system for very large single


flap,165)

Chainmotors + Rack & pinion


(Opening systems for windows and domes)

Performance

Notes

24V (2,5A) 48V (1,25A)


For dome width: 70-110 cm
Cover weight & snow: up to 140 kg

Adjustable from 70-110 cm

24V (3A/4A) 48V (1,5A/2A)


For dome width: 88-200 cm
Cover weight & snow: up to 300 kg

European patent

24V (2*3A/4A) 48V (2*1,5A/2A)


For dome width: 160-300 cm
Cover weight & snow: up to 2*300 kg
24V (6A/8A) 48V (3A/4A)
For dome width: 150-250 cm
Cover weight & snow: up to 400 kg
24VDC and 230VAC
Stroke length: 300 - 1000mm
Force: 300 1000N

European patent

EN 12101-2 & EN 12101-10 certificates

HCV 24V
HCVA 230V

HCVM 24V
HCMA 230V
HCMAR 230V+radio

Chainmotors

HTRW 24V
HTRWA 230V

Rack & Pinion motors

Installation cables - Example 1 of 3 (24V in Technic Room)

Building 2000m2 (72m x 28m x 7m)

24V system Actulux Control Panel SV 24V-24A mounted in Technic Room


2000m2 warehouse area (or production)

24m2 Aa - aerodynamic vent area

SHEVs / Domes

12 pcs. 2,4m x 1,2m (geometric daylight size) - cv0,7

Control panels:

2 pcs. SV 24V-24A (2 fire-comf. groups / control panel)

Opening systems:

12 pcs. SA Power Single 1,2m, 24V-4A / 48V-2A

Cable:

4 lines with 5x2,5mm2 cable (= 2 wire x 6,25mm2)

Total length of cable:

300m of 5x2,5mm2

Voltage drop:

15% max. 3,6v calculated 3,04

(or 12m2 for production)

Installation cables - Example 2 of 3 (24V decentral mounted)

Building 2000m2 (72m x 28m x 7m)

24V system Actulux Control Panel SV 24V-24A mounted decentralized


2000m2 warehouse area (or production)

24m2 Aa - aerodynamic vent area

SHEVs / Domes

12 pcs. 2,4m x 1,2m (geometric daylight size) - cv0,7

Control panels:

2 pcs. SV 24V-24A (2 fire-comf. groups / control panel)

Opening systems:

12 pcs. SA Power Single 1,2m, 24V-4A / 48V-2A

Cable:

4 lines with 5x1,5mm2 cable (= 2 wire x 3,75mm2)

Total length of cable:

172m of 5x1,5mm2

Voltage drop:

15% max. 3,6v calculated 3,04

(or 12m2 for production)

Installation cables - Example 3 of 3 (48V in Technic Room)

Building 2000m2 (72m x 28m x 7m)

24V system Actulux Control Panel SV 48V-24A mounted in Technic Room


2000m2 warehouse area (or production)

24m2 Aa - aerodynamic vent area

SHEVs / Domes

12 pcs. 2,4m x 1,2m (geometric daylight size) - cv0,7

Control panels:

1 pcs. SV 48V-24A (2 fire-comf. groups / control panel)

Opening systems:

12 pcs. SA Power Single 1,2m, 24V-4A / 48V-2A

Cable:

2 lines with 5x1,5mm2 cable (= 2 wire x 3,75mm2)

Total length of cable:

170m of 5x1,5mm2

Voltage drop:

15% max. 7,2v calculated 6,5

(or 12m2 for production)