Scientific Calculator: User'S Guide
Scientific Calculator: User'S Guide
Scientific Calculator: User'S Guide
LCD8110
G
USERS GUIDE
Olympia Business Systems Vertriebs GmbH
Weg zum Wasserwerk 10
45525 Hattingen
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disposal instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
4
4
4
6
6
Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Making corrections during input . . . . . . . . . . . . . . . . . . . . . . .
Replay function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exponential display formats . . . . . . . . . . . . . . . . . . . . . . . . . .
Answer memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
6
6
7
7
7
7
Basic Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Memory Calculations . . . . . . . . . . . . . . . . . . . . . . . . . .
8
8
Independent memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
8
Fraction calculations . . . . . . . . . . . . . . . . . . . . . . . . . .
DecimaltoFraction Conversion . . . . . . . . . . . . . . . . . . . . . . .
FractiontoDecimal Conversion . . . . . . . . . . . . . . . . . . . . . . .
9
9
Percentage calculation . . . . . . . . . . . . . . . . . . . . . . . .
Calculations Using Scientific Functions . . . . . . . . . . .
9
10
10
11
11
11
Statistical Calculations . . . . . . . . . . . . . . . . . . . . . . . .
14
14
14
15
15
16
17
11
12
13
13
13
13
17
17
Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Order of Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auto Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
18
19
19
19
20
22
LCD8110
Scientific Calculator
Safety Information
It is essential to read the following safety information before starting to use
the calculator. Keep this guide close to hand for reference later.
Intended Use
This calculator serves exclusively for completing arithmetical processes
indoors. Any other use is considered unintended use.
Batteries
l After removing the batteries from the calculator, put them in a safe
place where there is no danger of them getting into the hands of
small children and accidently swallowed.
l Keep batteries out of the reach of small children. If accidently
swallowed, consult with a physician immediately.
l Never charge batteries, try to take batteries apart, or allow batteries
to become shorted. Never expose batteries to direct heat or dispose
them by incineration.
l Misuse of batteries can cause them to leak and damage nearby
items. They also create the risk of fire and personal injury.
l Always make sure that a batterys positive (+) and negative () sides
are facing correctly when you load it into the calculator.
l Remove the batteries if you do not plan to use the calculator for a
long time.
l Use only the type of batteries specified for this calculator in this
manual.
Disposal instructions
The implementation of European law in domestic
legislation and national regulations requires a suitable
disposal of durable goods. The aim is to protect people
and the environment. The symbol on the side indicates
that old electrical and electronic devices should not be
disposed of in domestic waste.
After devices and equipment have reached the end of
their service life, they must be brought to a collection
point provided by an authorised waste disposal enterprise.
Old batteries must be returned to the pointofsale or to a collection
point provided by an authorised waste disposal enterprise.
Packing material must be disposed of according to local regulations.
l
l
l
l
l
l
l
Twoline Display
You can simultaneously check the calculation formula and its answer. The
first line displays the calculation formula. The second line displays the
answer.
Mode
name
Mode
identification
COMP
SD
REG
SD
REG
Deg
Rad
Gra
R
g
NORM 1
NORM 2
Fix
Sci
Fix
Sci
Note!
l Mode indicators appear in the lower part of the display.
l The COMP, SD and REG modes can be used in combination with the
angle unit modes.
l Be sure to check the current calculation mode (SD, REG, COMP)
and angle unit mode (DEG, RAD, GRA) before beginning a
calculation.
Input capacity
l The memory area used for calculation input can hold 79 "steps".
Whenever you input the 73rd step of any calculation, the cursor
changes from " to J to let you know memory is running low. If
you still need to input more, you should divide your calculations into
two or more parts.
Making corrections during input
l Use
and
to move the cursor to the location you want.
l Press
to delete the number or function at the current cursor
position.
6
Press
to change to an insert cursor . Inputting something
while the insert cursor is on the display inserts the input at the insert
cursor position.
Press
,
,
or
returns to the normal cursor from
the insert cursor.
Replay function
l Pressing
or
recalls the last calculation you performed. You
can then make any changes you want in the calculation and
reexecute it.
l Pressing
does not clear Replay memory, so you can recall the
last calculation even after you press
.
l Replay memory is cleared whenever you start a new calculation,
change to another mode or turn off power.
Error locator
l Pressing
or
after an error occurs displays the calculation
with the cursor positioned at the location where the error occured.
Exponential display formats
This calculator can display up to 10 digits. Larger values are automatically
displayed using exponential notation. In the case of decimal values, you
can select between two formats that determine at what point exponential
notation is used.
Press
(or
) to select NORM 1 or
NORM 2.
l NORM 1
With NORM 1, exponential notation is automatically used for integer values
with more than 10 digits and decimal values with more than two decimal
places.
l NORM 2
With NORM 2, exponential notation is automatically used for integer values
with more than 10 digits and decimal values with more than nine decimal
places.
l All of the examples in this manual show calculation results using the
NORM 1 format.
Answer memory
l Whenever you press
after inputting values or an expression, the
calculated result is automatically stored in Answer Memory. You can
recall Answer Memory contents by pressing
.
l Answer Memory can store up to 12 digits for the mantissa and two
digits for the exponent.
l Answer Memory contents are not changed if the operation performed
by any of the above key operations results in an error.
Basic Calculations
Note!
Use the
key to activate COMP mode in order to carry out basic
calculations.
COMP:
Example 1.:
3x(5x109)
3
Example 2.:
5x(9+7)
5
5
9
1.508
80.
Memory Calculations
Note!
Use the
key to activate COMP mode to complete calculations
using the memory.
COMP:
Independent memory
l The values can be entered directly in the memory or added to and
subtracted from the memory. Independent memory is convenient for
calculating cumulative totals.
l Independent memory uses the same memory area as variable M.
l To clear independent memory, input
.
Example 1.:
23+9=32
536=47
)45x2=90
(Total) 11
23
9
53
45
32.
6
47.
90.
11.
Variables
l There are nine variables (A through F, M, X and Y), which can be
used to store data, constants, results and other values.
l Use the following operation to delete data assigned to all nine
key.
variables:
l Use the following operation to delete data assigned to a particular
variable:
. This operation deletes the data assigned to
variable A.
Example 1.:
193.2:23=8.4
193.2:28=6.9
193.2
23
28
8.4
6.9
Fraction calculations
Note!
key to activate COMP mode when you want to perform
Use the
fraction calculations. COMP:
l Values are automatically displayed in decimal format whenever the
total number of digits of a fractional value
(integer+numerator+denominator+separator marks) exceeds 10.
Example 1.: 2 + 1 4
3
5
2
3
1
4
5
2 7 15.
Example 2.: 1 + 1,6
2
1
2
1.6
2.1
l
DecimaltoFraction Conversion
Example 1.: 2.75 2 3
4
2.75
2.75
2 3 4.
11 4.
FractiontoDecimal Conversion
Example 1.: 1 0.5 (Fraction Decimal)
2
1
2
1 2.
0.5
1 2.
Percentage calculation
Note!
key to activate COMP mode in order to carry out
Use the
calculation of percentages. COMP:
Example 1.: Calculate 12% of 1500
1500
12
Example 2.: To calculate what percentage of 880 is 660
660
880
9
180.
75.
15
2875.
2625.
Example 5.: If 300 grams are added to a test sample originally
weighing 500 grams, what is the percentage increase in
weight?
300 + 500
x 100 = 160 (%)
500
300
500
160.
Example 6.: What is the percentage increase when a temperature
rises from 40 C to 46 C?
46 40
x 100 = 15 (%)
40
40
46
15.
52
o" "
0.897859012
o" "
0.5
o" "
0.785398163
41
rad )
3
Example 3.:
cos1
2
= rad
2
4
0.25
Example 4.: tan1 0.741
o" "
0.741
10
36.53844577
18.28545536
30
4.094622224
Pressing
,
or
converts the displayed value to the
corresponding angle unit.
Example 1.: To convert 4.25 radians to degrees:
o" "
4.25r
4.25
(R)
243.5070629
l
0.089905111
90
4.49980967
10
22026.46579
1.5
31.6227766
16.
2 + 3 x 5
2
Example 2.:
35+327
3
5
Example 3.:
5.287196909
27
1.290024053
123
1.988647795
1
7
123 ( = 123 )
7
30
11
1023.
1728.
1
Example 6.: 1 1
3 4
3
12.
Example 7.: 8!
8
40320.
9.424777961
14
400.
400.000
Fix
28.571
14
Complete the same calculation with the defined
number of decimal places
200
7
(Internal rounding)
400.000
14
399.994
28.571
28.571
l Press
to delete the FIX entry.
Example 2.: 1y3, to display results with two significant digits (SCI2).
Press
1
3
to delete the SCI entry.
12
3.301
Scl
ENG Calculations
Example 1.: Convert 56088 meters to kilometers.
56088
56.08803
81.2503
60
1.
1.732050808
,
swaps displayed value with value in memory.
Example 2.: To convert rectangular coordinates (1, 3 ) to polar
coordinates
(r, T) (RAD mode)
r
1
3
2.
l
T
l
1.047197551
swaps displayed value with value in memory.
Permutation
Example 1.: To determine how many different 4digit values can be
produced using the numbers 1 through 7.
l Numbers cannot be duplicated within the same 4digit value (1234 is
allowed, but 1123 is not).
4
7
840.
Combination
Example 1.: To determine how many different 4member groups can
be organized in a group of 10 individuals.
10
4
210.
13
Statistical Calculations
Note!
Use the
key to activate SD mode to complete statistical
calculations using standard deviation.
SD:
Standard Deviation (SD mode)
l Data input always starts with
to clear statistical memory.
l Input data is used to calculate values for , ,
, , , which you can recall using the key
operations noted nearby.
14
Quadratic regression
Data input always starts with
to clear statistical memory.
The values produced by a regression calculation depend on the
values input, and results can be recalled using the key operations
shown in the table below.
Regression coefficient A
Regression coefficient B
Regression coefficient C
Correlation coefficient r
(estimated value of x)
(estimated value of y)
Linear regression
The regression equation for linear regression is: y = A+Bx.
Example 1.: Atmospheric pressure vs. temperature
Temperature
10C
15C
20C
25C
30C
Atmospheric pressure
1003 hPa
1005 hPa
1010 hPa
1011 hPa
1014 hPa
15
1003
15
1005
20
1010
25
1011
30.
30
1014
REG..............
(Regression coefficient A)
997.4
(Regression coefficient B)
0.56
(Correlation coefficient r)
0.982607368
(Atmospheric pressure at 18C)
18
1007.48
1000
4.642857143
Quadratic regression
l The regression equation for quadratic regression is:
y = A+Bx+Cx 2
l Input data using the following key sequence.
<xdata>
<ydata>
l Example:
xi
29
50
74
103
118
yi
1.6
23.5
38.0
46.4
48.0
1.6
38.0
50
103
118
23.5
46.4
48.0
118.
REG
(Regression coefficient A)
35.599856934
(Regression coefficient B)
1.495939413
(Regression coefficient C)
6.7162966703
16
( when xi = 16)
16
13.38291067
20
47.14556728
( when yi = 20)
(
when yi = 20)
175.5872105
Precautionary measures when entering data
l
inputs the same data twice.
l You can also input multiple entries of the same data using
.
To input the data "20 and 30" five times, for example, press 20
30
5
.
l The above results can be obtained in any order, and not necessarily
that shown above.
l To delete data you have just input, press
.
21528.8
Example 2.: To perform the following calculation:
123456" x 3.45
12
34
56
3.45
432431.2
Technical Information
When you have a problem...
If calculation results are not what you expect or if an error occurs, perform
the following steps.
1.
(COMP mode)
(DEG mode)
2.
(NORM 1 mode)
3.
4. Check the formula you are working with to confirm it is correct.
5. Enter the correct modes to perform the calculation and try again.
17
Error messages
The calculator is locked up while an error message is on the display. Press
to clear the error, or press
or
to display the calculation and
correct the problem.
Ma ERROR
l Cause
l Calculation result is outside the allowable calculation range.
l Attempt to perform a function calculation using a value that exceeds
the allowable input range.
l Attempt to perform an illogical operation (division by zero, etc.).
l Action
l Check your input values and make sure they are all within the
allowable ranges. Pay special attention to values in any memory
areas you are using.
Stk ERROR
l Cause
l Capacity of the numeric stack or operator stack is exceeded.
l Action
l Simplify the calculation. The numeric stack has 10 levels and the
operator stack has 24 levels.
l Divide your calculation into two or more separate parts.
Syn ERROR
l Cause
l Attempt to perform an illegal mathematical operation.
l Action
l Press
or
to display the calculation with the cursor located at
the location of the error. Make necessary corrections.
Arg ERROR
l Cause
l Improper use of argument
l Action
l Press
or
to display the location of the cause of the error and
make required corrections.
Order of Operations
Calculations are performed in the following order of precedence.
1. Coordinate conversion: Pol (x, y), Rec (r, T)
2. Type A functions: With these functions, the value is entered and then
the function key is pressed.
x2, x1, x!,
3. Powers and roots: xy, x
4. a b/c
5. Abbreviated multiplication format in front of S, memory name, or
variable name: 2S, 5 A, SA etc.
6. Type B functions: With these functions, the function key is pressed
and then the value is entered.
, 3 , log, In, ex, 10x, sin, cos, tan, sin1, cos1, tan1, sinh, cosh,
tanh, sinh1, cosh1, tanh1, ()
7. Abbreviated multiplication format in front of Type B functions: 23,
Alog2 etc.
8. Permutation and combination: nPr, nCr
18
9. x, y
10. + ,
Operations of the same precedence are performed from right to left,
exIn120 > eX{In(120)}. Other operations are performed from left to right.
Operations enclosed in parentheses are performed first.
Stacks
This calculator uses memory areas, called "stacks", to temporarily store
values (numeric stack) and commands (command stack) according to their
precedence during calculations. The numeric stack has 10 levels and the
command stack has 24 levels. A stack error (Stk ERROR) occurs
whenever you try to perform a calculation that is so complex that the
capacity of a stack is exceeded.
Replacing the Battery
Dim figures on the display off the calculator indicate that battery power is
low. Continued use of the calculator when the battery is low can result in
improper operation. Replace the battery as soon as possible when display
figures become dim.
1. Press
to turn power off.
Screw
2. Remove the one screw that hold the battery
cover in place and then remove the battery
cover.
3. Remove the old battery.
4. Wipe off the sides of new battery with a dry,
soft cloth. Load it into the unit with the
positive
side facing up (so you can see
it).
5. Replace the battery cover and secure it in
place with the one screw.
6. Use a thin, pointed object to press the
Reset button. Be sure not to skip this step.
7. Press
to turn power on.
Auto Power Off
Calculator power automatically turns off if you do not perform any operation
for about six minutes. When this happens, press
to turn power on.
19
Input ranges
Internal digits: 12
Accuracy: As a rule, accuracy is +/ 1 at the 10th digit.
Functions
Input range
20
Functions
Input range
(x is an integer)
(n, r is an integer)
(n is an integer)
However:
is an integer)
However:
Total of integer, numerator, and denominator must
be 10 digits or less (including division marks).
Note!
Error are cumulative with such internal continuous calculations as xy, x,
x!, so accuracy may be adversely affected.
21
Guarantee
Dear Customer,
We are very pleased that you have decided to buy this product. Should the
device show signs of a defect, please return it, together with the purchase
receipt and original packing, to the pointofsale.
Homepage
User manuals for the following countries are available on the
www.olympiavertrieb.de homepage:
Germany, France, Italy, England, Portugal, Netherland, Greece, Finland,
Czech Republic, Sweden, Slovakia, Hungary, Denmark, Croatia and
Slovenia.
Hotline Germany: 0180 5012370 (0,14 per minute)
Hotline foreign countries: 00800 10022100
LCD8110
EN 55022: 2006
EN 55024: 1998 + A1: 2001+A2:2003
R
Olympia Business Systems Vertriebs GmbH
Weg zum Wasserwerk 10
45525 Hattingen
August 2008
22
23