This verification will be comparing the result from RCM ACI-BUILDER with ACI SP17 (05).
To do so, this verification using some examples calculation on ACI SP17 (05) to be applicated
in RCM ACI-Builder, then analyze the disparity among them.
Analysis:
This example will be comparing between ACI SP17 and RCM Builder on side steel area that
is required to accommodate Mu load.
The result is, Based on ACI SP 17(05) example,
2
As required =
1.22 in
2
=
787.10 mm
and RCM Builder (ACI318-11) calculate, (see at Attachment - Example 1)
785.03
If we comparing this two results, the accuracy between RCM Builder to manual calculation is
2
Deviation = (As RCM - As ACI) =
-2.07 mm
Accuracy = (As RCM/As ACI)% =
99.7%
Analysis:
This example will be comparing between ACI SP17 and RCM Builder on side steel area that
is required to accommodate Mu load.
The result is, Based on ACI SP 17(05) example,
2
As required =
2.85 in
2
= 1838.71 mm
and RCM Builder (ACI318-11) calculate, (see at Attachment - Example 2)
1814.52
If we comparing this two results, the accuracy between RCM Builder to manual calculation is
2
Deviation = (As RCM - As ACI) =
-24.19 mm
Accuracy = (As RCM/As ACI)% =
98.7%
In SI unit,
If we comparing this two results, the accuracy between RCM Builder to McCormac calculation is
2
Deviation = (As RCM - As ACI) =
-1.74 mm
Accuracy = (As RCM/As ACI)% =
99.8%
d
d'
As required =
=
As required =
=
(Tension bar)
(Compression bar)
9.6 in
2
6193.54 mm
As required =
=
2.01 in
2
1296.77 mm
As required =
If we comparing this two results, the accuracy between RCM Builder to McCormac calculation is
2
Deviation = (As RCM - As ACI) =
-0.41 mm
Deviation = (As RCM - As ACI) =
Accuracy = (As RCM/As ACI)% =
Accuracy = (As RCM/As ACI)% =
80.03 mm