Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

EP Engineering - Top 5 MEP Mistakes To Avoid

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MEPCONSULTANTS

LicensedinNY,NJ,CT,MD&PA

EnteryouremailaddresstorecieveourNewsletter

HOME

Top5MEPMistakes
toAvoid
UsingVRFinOffice
Spaces
AvoidingChange
Orders
BaseBuilding
Checklist
Residential&Mixed
UseDevelopments
MEPBasics
Retro
Commissioning
EmergencyPower
Systems
EnergyAudits
2010NYECC
FrequentlyAsked
Questions
Benchmarking:
ReducingNYC's
CarbonFootprint
BuildingaSuccessful
Restaurant
NYCSpecial
Inspections
EnergyStarWhat
isitandhowdoyou
getcertified?

PORTFOLIO

EPTHRIVES

EPCARES

ABOUT

Like 584

RESOURCES

CONTACT

TOP5MEPMISTAKESTOAVOID
Weveseenourshareofissuescomeuponprojectswhichcanbeavoidedwithsimplecoordination
duringtheearlydesignphases.
Herearethetop5issueswehaveseenonprojectsandhowtoavoidthem:

1)Notusingthelatestbackgrounds
Thisisprobablythemostcommondesignmistakethathappensonconstructionprojects.Oftentimes
thearchitectisworkingontheirbackgroundsuptothelasthourthatthejobgoesout.Theengineers
usuallyarethensubmittingasetthatdoesnothavethelatestarchitecturalbackgrounds
incorporated.Thebestwaytoavoidthismistakeistohavethearchitectfreezetheirbackgrounds1
weekpriortotheprojectbeingsubmittedforbid.Ifforsomereasonthearchitecthadtomake
changesduringthatweek,theFINALbackgroundcanbesubmittedtoengineerimmediatelyandthen
anaddendumcanbepreparedsothebiddershaveacoordinatedsetofarchitecturaland
engineeringplanspriortosubmittingtheirfinalnumber.

2)NotUnderstandingHoursofOperation
Whendesigningaspaceoneofthefirstquestionstheengineershouldbeaskingiswhetherornot
thespacewillneedtofunctionafterhours.Thenthebuildingsystemandleasemustbeinvestigated
toseeifthebaseinfrastructurecanprovidecoolingandheatingduringthesetimes.Forinstance,ifa
tenanthastoworkonSaturdaysandthebuildingHVACsystemdoesnotoperateonweekends,a
supplementalsystemisneeded.Ifthisisomittedfromthedesign,thetenantwillincurgreatcoststo
providethisaftertheconstructioniscomplete.

3)NotCoordinatingWorkinFloorBelow
Anotherimportantduediligenceitemduringtheearlydesignstagesistofindoutifthebuildingwill
allowworkinthefloorbelow.Thisiscriticalforelectricalconnectionstoremote/islandfurniture
andalsofornewplumbingfixtureswhosedrainscomeoutintotheceilingofthespacebelow.Ifthe
buildingdoesnotallowforthisworkorifitphysicallyisnotpossibleduetoobstructionsintheceiling
below,thedesignteammusttakeproperstepstoproviderequiredservices,suchastrenching
electricalconnectionsorpumpingtheplumbingdrains.

4)UndersizedAirConditioningSystems
Adreadedoccuranceonanyprojectiswhentheuseroccupiesthespaceandfindsouttheycannot
keepitcool.Therearemanyfactorsthatcanleadtothishappening,butthemostcommononeis

NYCProgress
Inspections
BackflowPrevention
LocalLawDeadlines
NYCEnergy
ConservationCode
HVAC
Commissioning101
Architectsand
Engineers,Formand
Function.Working
TogetheristheKey!
AvoidingChange
Orders:HowtoKeep
CostsDownand
YourProjecton
Schedule

whentheoccupancyofspace(#ofpeople)differsfromwhatwasdesigned.Theengineermay
designaconferenceroomACunitfor10peoplebuttheuserisactuallyputting20peopleintothe
space.Thiscanbeavoidedwithasimplediagramprovidedbytheengineerwhichshowstothe
Ownertheheadcountstheyaredesigningforineachroom.TheOwnerwouldthensignoffonthis
diagramastheirintendeduse.

5)NotComplyingwithEnergyCodeforEconomizers
2014EnergyCodechangedalotofeconomizerexemptions.WecannolongeruseAshrae90.12007
whichallowedanysysteminNYCclimatezonetobeexemptfromeconomizers.Now,tobeexempt,
thedesignteammustusetheexemptionssetforthinthecode.Themostcommonexemptionisto
increasethecoolingefficiencyoftheequipmentby42%ormoreabovethecodeminimum
efficiencies.ThiscanbedoneeasilywithcreativeHVACdesignandutilizationofVRFtechnology(i.e.
minisplit).
Economizercodecomplainceisacriticalstepofthedesignphasesinceomittinganeconomizerand
havingtoinstallonelatercanhavedisastrousramificationssincetheyrequirecompletelydifferent
HVACinfranstructure.