Cable Inventory 07-15-15 Web
Cable Inventory 07-15-15 Web
Cable Inventory 07-15-15 Web
GRADE CABLES
NORTH AMERICA FACTORY INVENTORY
TELE-FONIKA KABLE
TELE-FONIKA KABLE SA, a privately held wire and cable manufacturer headquartered in Krakow,
Poland, is one of the largest wire and cable companies in the world. TF operates 8 plants in Central
and Eastern Europe with a distribution network stretching 90 countries. Formed through a series of
acquisitions and mergers, TFK has developed world-class technology centers of excellence with state
of the art manufacturing operations. Founded in 1992, TF grew rapidly and the operations today are
a result of internal development projects supported by strategic investments.
TF is the leading medium and high voltage cable manufacturer in Europe with significant market share
in rubber insulated portable power cables used by HEAVY INDUSTRY & MINING. Additionally, the
company manufactures products for the TELECOMMUNICATION, SHIP BUILDING, ELECTRONIC
and ENERGY sectors.
All manufacturing facilities are ISO 9001, ISO 2000, and ISO 14001 certified. All products
are manufactured to public, utility and industrial standards including ICEA, IEEE, and ASTM.
Tele-Fonika has over 400 individual certificates issued by more than 30 governing bodies
which include UL, CSA, MSHA, SABS, VDE, CE, etc.
TABLE OF CONTENTS
INDUSTRIAL GRADE PORTABLE POWER 2000V
W 1/C RHH/RHW-2 2000V Extra Flex 90C UL, C(UL), MSHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
W 2 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
W 3 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
W 4 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
W 5 /C & 6 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
G-GC 3/C 2000V 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
G 4/C 2000V 90C - UL ,C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DLO / RHH / RHW-2 / 2000V / RW90 1000V 90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . 8
DLO / RHH / RHW-2 / 2000V / RW90 1000V 90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . 9
MINING GRADE POWER 2000V - 15000V
W 4/C 2000V Mining Grade 90C - UL, C(UL), MSHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
G-GC 3/C 2000V Mining Grade 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
G-GC 3/C 2000V Mining Grade 90C - UL, C(UL), MSHA (CSA Canada color code) . . . . . . . . . . . . . 12
MP-GC 3/C 5000V / 15000V - XLP / PVC Mining Grade 90C - MSHA (CSA available). . . . . . . . . . . 13
MP-GC 3/C 8000V / 15000V - EPR / CPE Mining Grade 90C - MSHA . . . . . . . . . . . . . . . . . . . . . . . 14
SHD-GC 3/C 2000V 90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SHD-GC 3/C 2000V 90C - CSA, MSHA (CSA Canada Color Code) . . . . . . . . . . . . . . . . . . . . . . . . . 16
SHD-GC 3/C 5000V 90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SHD-GC 3/C 5000V 90C - CSA, MSHA (CSA Canada Color Code). . . . . . . . . . . . . . . . . . . . . . . . . . 18
SHD-GC 3/C 8000V / 15000V 90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SHD-GC 3/C 8000V / 15000V 90C - CSA, MSHA (CSA Canada Color Code). . . . . . . . . . . . . . . . . . 20
PORTABLE CORD AND CONTROL 300V - 600V
SJOOW 300V Flextreme Portable Cord -40C +90C - UL, CSA, MSHA . . . . . . . . . . . . . . . . . . . . . . . 21
SOOW 600V Flextreme Portable Cord -40C +90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . 22
SOOW 600V Power Cable -40C +90C - UL, CSA, MSHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
SOOW 600V Power Cable -40C +90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
SOOW 600V Controlflex Control Cable -40C +90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . 25
SOOW 600V Controlflex Control Cable -40C +90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . 26
SOOW 600V Super Flextreme Portable Cord -50C + 105C - UL, CSA, MSHA . . . . . . . . . . . . . . . . . 27
SOOW H07RN-F 600V Flextreme Portable Cord -40C + 90C - UL, CSA, MSHA, <HAR>. . . . . . . . . 28
SC Stage Lighting 600V 105C - UL, C(UL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
INDUSTRIAL GRADE POWER, WELDING, LIGHTING 600V
USE-2 RHH / RHW 600V 90C - UL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Arc Welding Cable 600V Zero Halogen 105C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Remote Drill Cord 600V -40C +90C - MSHA & Jumper Cable 15000V Utility Grade. . . . . . . . . . . . . 32
UTILITY GRADE
Grounding Cable 600V PVC Utility Grade & Grounding Cable 600V CPE Utility Grade . . . . . . . . . . 33
GENERAL INFORMATION
TF SAP INDEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-37
Terms and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
TELE-FONIKA CABLE SUPPLIES PRODUCTS ACCORDING TO:
MSHA
2000V W RHH/RHW-2
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade
SPECIFICATIONS & STANDARDS
ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Reinforcement:
Jacket:
Extra flexible strand bare copper (Standard Flex tin copper), B-172 and ICEA S-75-381/NEMA WC70
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-95-658 sec.3.21, table 3-6
Nylon open braid applied over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381/NEMA WC70 sec 3.21, table 3-4
FEATURES
APPLICATION
Super-excellent flexibility
Water resistant and flame retardant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone, sunlight, oil, grease, weather, chemical resistant
APPROVALS:
UL:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
C(UL):
E207132 FT1; FT5; -40C +90C
MSHA: P-7K-268101
EXTRA FLEX
Part Number
W8-1X
W6-1X
W4-1X
W2-1X
W1-1X
W1/0-1X
W2/0-1X
W3/0-1X
W4/0-1X
W250-1X
W350-1X
W500-1X
Power Conductor
Size
Power Conductor
Stranding
Nominal Insulation
Thickness
AWG or MCM
No. of Wires
inches
mm
inches
mm
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
162/30
264/30
418/30
660/30
836/30
1056/30
1320/30
1672/30
2090/30
2496/30
3416/30
4880/30
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
0.441
0.511
0.564
0.651
0.729
0.751
0.800
0.856
0.981
1.001
1.133
1.255
11.2
12.9
14.3
16.5
18.5
19.0
20.3
21.7
24.9
25.4
28.8
31.9
Nominal O.D.
Approx. Weight
Ibs/1000 ft
145
200
255
375
475
530
650
750
970
1130
1420
1913
kgs/km
216
298
379
558
707
789
967
1116
1444
1682
2116
2847
A
80
105
140
190
220
260
300
350
405
455
570
700
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE W 2000V PORTABLE POWER CABLE RHH/RHW-2 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1
FT5 (-40C) P-7K-268101-MSHA
phone: 630-406-9000
www.tfcable.com
W 2000V
ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:
Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-8
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white
FEATURES
APPLICATIONS
Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101
2 CONDUCTOR
Part
Number
W8-2
W6-2
W4-2
W2-2
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
8 AWG
6 AWG
4 AWG
2 AWG
133 7x19
259 7x37
259 7x37
259 7x37
Nominal Insulation
Thickness
Nominal
O.D.
Ampacity (1)
30C
Ambient Temp.
Approx.
Weight
inches
mm
inches
mm
lbs/1000 ft
kgs/km
0.060
0.060
0.060
0.060
1.52
1.52
1.52
1.52
0.83
0.94
1.07
1.26
21.1
23.9
27.3
32.1
391
571
793
1142
581
849
1180
1699
74
99
130
174
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA
www.tfcable.com
phone: 630-406-9000
2000V w
ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:
Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-9
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white, green
FEATURES
APPLICATIONS
Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101
3 CONDUCTOR
Part
Number
W8-3
W6-3
W4-3
W2-3
W1-3
W1/0-3
W2/0-3
W3/0-3
W4/0-3
W250-3
W350-3
W500-3
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
inches
mm
inches
mm
lbs/1000 ft
kgs/km
133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28
627 19x33
888 37x24
1221 37x33
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
0.91
1.01
1.05
1.32
1.51
1.63
1.73
1.85
1.99
2.39
2.66
2.98
23.1
25.7
26.5
33.6
38.4
41.4
44.0
47.0
50.6
60.7
67.5
75.8
541
715
1010
1405
1734
2030
2566
2885
3479
4368
5895
7820
805
1064
1503
2091
2581
3010
3818
4293
5177
6500
8772
11638
65
87
114
152
177
205
237
274
316
352
433
536
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
Nominal Insulation
Thickness
Nominal
O.D.
Ampacity (1)
30C
Ambient Temp.
Approx.
Weight
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA
phone: 630-406-9000
www.tfcable.com
W 2000V
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade
ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:
Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-10
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white, green, red
FEATURES
APPLICATIONS
Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101
4 CONDUCTOR
Part
Number
W8-4
W6-4
W4-4
W2-4
W1-4
W1/0-4
W2/0-4
W3/0-4
W4/0-4
W250-4
W350-4
W500-4
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28
627 19x33
888 37x24
1221 37x33
Nominal
Insulation
Thickness
Nominal
O.D.
Ampacity (1)
30C
Ambient Temp.
Approx.
Weight
inches
mm
inches
mm
Ibs/1000 ft
kgs/km
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
0.97
1.11
1.26
1.47
1.71
1.78
1.89
2.02
2.22
2.61
2.92
3.34
24.6
28.3
32.1
36.3
43.4
45.2
48.0
51.4
56.3
66.2
74.2
84.8
656
908
1262
1759
2322
2721
3293
3849
4765
5579
7329
9896
976
1352
1878
2618
3456
4050
4901
5729
7092
8303
10908
14729
52
69
91
121
141
164
189
219
252
281
346
428
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
www.tfcable.com
phone: 630-406-9000
2000V W
ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:
Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-16
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white, red, green, orange
FEATURES
APPLICATIONS
Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101
5 CONDUCTOR
Part
Number
W8-5
W6-5
W4-5
W2-5
W1-5
W1/0-5
W2/0-5
W3/0-5
W4/0-5
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28
Nominal
Insulation
Thickness
Nominal
O.D.
Ampacity (1)
30C
Ambient Temp.
Approx.
Weight
inches
mm
inches
mm
Ibs/1000 ft
kgs/km
0.06
0.06
0.06
0.06
0.06
0.08
0.08
0.08
0.08
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
1.07
1.24
1.36
1.56
1.85
1.98
2.13
2.27
2.46
27.2
31.5
35.2
39.8
47.1
50.4
54.1
57.6
62.6
776
1024
1432
2051
2665
3406
3596
4728
5512
1154
1524
2131
3052
3967
5069
5351
7035
8203
52
69
91
121
141
164
189
219
252
6 CONDUCTOR
Part
Number
W6-6
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
6 AWG
259 7x37
Nominal
Insulation
Thickness
Nominal
O.D.
Ampacity (1)
30C
Ambient Temp.
Approx.
Weight
inches
mm
inches
mm
Ibs/1000 ft
kgs/km
0.06
1.52
1.30
33.0
1272
1891
69
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5
(-40C) P-7K-268101-MSHA
phone: 630-406-9000
www.tfcable.com
G-GC 2000V
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade
CONSTRUCTION:
Conductors:
Flexible strand tin copper, Class I UL44 and ASTM B 33
Insulation:
Ethylene-propylene rubber (EPR)
Grounding conductors: Tin copper, insulation color: green
Ground check:
Yellow polypropylene-insulated tin copper conductor
Assembly:
Three power, ground check and two EPR insulated grounding conductors cabled together to form round core
Separator:
Single faced rubber filled binder tape applied overall
Jacket:
Black heavy duty, integral-filled CPE thermoset compound, UL 1581
Color Code:
table 3-4; Black, white, red
FEATURES
APPLICATION
- U
se on AC off track equipment such as miners, shuttle cars,
cutting machines, loading machines, drills, conveyors, and pumps
- Power to open pit strip and deep mines
- For applications requiring ground check conductor for added safety.
Excellent flexibility
Ozone, sun, weather and flame resistant
Rated and flexible at 40C to 90C
Excellent impact and abrasion resistant
Oil and heat resistant
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 FT1; FT5; -40C +90C
P-7K-268101
3 CONDUCTOR
Part
Number
GGC8-3
GGC6-3
GGC4-3
GGC2-3
GGC1-3
GGC1/0-3
GGC2/0-3
GGC3/0-3
GGC4/0-3
GGC250-3
GGC350-3
GGC500-3
Size
Power
Conductor
Size
Power
Conductor
Stranding
Ground
Ground
Check
AWG or MCM
No. of Stranding
AWG
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
133 7x19
133 7x19
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28
627 19x33
888 37x24
1221 37x33
10
10
8
7
6
5
4
2
2
2
1/0
2/0
Ampacity (1)
30C Ambient
Temp.
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
AWG
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
10
10
10
10
8
8
8
8
8
8
8
8
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.141
0.141
0.125
0.141
0.141
0.156
0.156
0.156
0.172
0.240
0.240
0.270
0.99
1.05
1.12
1.29
1.41
1.54
1.60
1.74
1.88
2.26
2.48
2.87
25.1
26.6
28.4
32.8
35.8
39.0
40.6
44.3
47.7
57.3
63.1
72.8
661
781
1013
1413
1716
2096
2466
2982
3627
4568
6003
8131
983
1162
1507
2103
2554
3119
3670
4437
5397
6798
8933
12099
65
87
114
152
177
205
237
274
316
352
433
536
Nominal
O.D.
Approx.
Weight
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE G-GC PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA
Jacket:
MSHA:
CSA:
Jacket: TPU
MSHA:
6
www.tfcable.com
phone: 630-406-9000
2000V G
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade
ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44, UL 1581
CONSTRUCTION:
Conductors:
Insulation:
Grounding cond:
Assembly:
Separator:
Jacket:
Color Code:
Flexible strand tin copper, ASTM B-172 Class I and ICEA S-75-381/NEMA WC58
Ethylene-propylene rubber (EPR); ICEA S-75-381 sec 3.15, table 3-10
ICEA S-75-381; insulation color: green
Four power and four EPR insulated grounding conductors cabled with rubber filler in center to form round core
Single faced rubber filled binder tape applied overall
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.21, table 3-4
ICEA S-75-381 sec 3.21 table 3-4; black, white, red, orange
FEATURES
APPLICATION
- U
se on AC off track equipment such as miners, shuttle cars,
cutting machines, loading machines, drills, conveyors, and pumps
- Power to open pit strip and deep mines
Excellent flexibility
Ozone, sun, weather and flame resistant
Rated and flexible at 40C to 90C
Excellent impact and abrasion resistant
Oil and heat resistant
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101
4 CONDUCTOR
Power
Conductor
Size
Power
Conductor
Stranding
Grounding
Conductor
Size
Nominal
Insulation
Thickness
AWG or MCM
AWG
inches
inches
mm
lbs/1000ft
kgs/km
12
12
10
9
8
7
6
5
4
3
1
1/0
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.99
1.10
1.27
1.48
1.68
1.79
1.93
2.07
2.26
2.66
2.98
3.40
25.1
27.9
32.3
37.6
42.7
45.5
49.0
52.6
57.4
67.6
75.7
86.4
748
910
1378
1914
2311
2810
3253
4099
4925
6060
8126
10758
1113
1354
2050
2848
3439
4181
4842
6100
7329
9018
12093
16010
52
69
91
121
141
164
189
219
252
281
346
428
Part
Number
G8-4
G6-4
G4-4
G2-4
G1-4
G1/0-4
G2/0-4
G3/0-4
G4/0-4
G250-4
G350-4
G500-4
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
259 37x7
532 19x28
627 19x33
888 37x24
1221 37x33
Nominal
O.D.
Ampacity (1)
30C Ambient Temp.
Approx.
Weight
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE G PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA
phone: 630-406-9000
www.tfcable.com
DLO/RHH/RHW-2/RW90/RW90-TC 2000V
Portable Power Cable 90C UL CSA MSHA
Industrial Grade
UL 44, ICEA S-95-658/NEMA WC70, UL 1685, IEEE-1202, CSA C22.2 No. 38, CSA C22.2 No. 230, ASTM B 8, ASTM B 33, AAR, RP-588 RP-586
CONSTRUCTION:
Nominal voltage:
Conductors:
Separator:
Insulation:
Jacket:
Bending radius:
FEATURES
APPLICATION
APPROVALS:
UL: E193954 (CPE jacket) RHW-2 90C wet and dry, VW-1, Sun Res, for 1/0 and larger ST-1, FT-4, IEEE1202, for CT use
C(UL):
E193954: TYPE RW90 EPR; 1000V; FT1
CSA:
1101269 LL103932: 205591; RW-90 90C; FT1; FT4; -40C; for 1/0AWG and larger: OIL RES, Tray Cable, Sun Res
MSHA:
P-7268080-01-MSHA
Part
Number
DLO14
DLO12
DLO10
DLO8
DLO6
DLO4
DLO2
DLO1
DLO1/0
DLO2/0
DLO3/0
DLO4/0
Power
Conductor
Size
Power
Conductor
Stranding
Conductor
Diameter
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
AWG or MCM
No. of Stranding
inches
inches
inches
inches
mm
0.074
0.094
0.128
0.147
0.207
0.264
0.314
0.390
0.420
0.460
0.555
0.587
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045
0.193
0.217
0.248
0.323
0.362
0.413
0.489
0.583
0.642
0.681
0.781
0.815
4.9
5.5
6.3
8.2
9.2
10.5
12.4
14.8
16.3
17.3
19.8
20.7
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
19/27
19/25
27/24
37/24
61/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
Nominal
O.D.
Ampacity
at Ambient
Temp. 30C
Approx.
Weight
Ibs/1000 ft
25
46
67
95
134
192
248
428
480
558
742
872
kgs/km
37
68
100
141
199
286
369
637
714
830
1104
1298
A
35
40
55
80
105
140
190
220
260
300
350
405
*** Based on single conductor in free air, 30C ambient air temperature 90C conductor temperature per 2005 NEC Table 310.17
1 AWG AND SMALLER: TF CABLE (SIZE) 90C DLO 2KV P-7K-268080-01-MSHA - E193954 (UL) RHW2 2KV VW1 SUN RES - (CSA) 205591
RW90 EPR 1000V -40C FT1 FT4
1/0 AWG AND LARGER: TF CABLE (SIZE) 90C DLO 2KV P-7K-268080-01-MSHA - E193954 (UL) RHW2 2KV VW-1 ST1 SUN RES (CSA)
205591 RW90 EPR 1000V -40C FT1 FT4 TC SR OIL RES
www.tfcable.com
phone: 630-406-9000
2000V DLO/RHH/RHW-2/RW90/RW90-TC
Portable Power Cable 90C UL CSA MSHA
Industrial Grade
UL 44, ICEA S-95-658/NEMA WC70, UL 1685, IEEE-1202, CSA C22.2 No. 38, CSA C22.2 No. 230, ASTM B 8, ASTM B 33, AAR, RP-588 RP-586
CONSTRUCTION:
Nominal voltage:
Conductors:
Separator:
Insulation:
Jacket:
Bending radius:
FEATURES
APPLICATION
APPROVALS:
UL: E193954 RHW-2 90C wet and dry, VW-1, Sun Res, for 1/0 and larger ST-1, FT-4, IEEE1202, for CT use
C(UL):
E193954: TYPE RW90 EPR; 1000V; FT1
CSA:
1101269 LL103932: 205591; RW-90 90C; FT1; FT4; -40C; for 1/0AWG and larger: OIL RES, Tray Cable, Sun Res
MSHA:
P-7268080-01-MSHA
Part
Number
DLO262
DLO313
DLO373
DLO444
DLO535
DLO646
DLO777
DLO929
DLO1111
Power
Conductor
Size
Power
Conductor
Stranding
Conductor
Diameter
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
AWG or MCM
No. of Stranding
inches
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
262 MCM
313 MCM
373 MCM
444 MCM
535 MCM
646 MCM
777 MCM
929 MCM
1111 MCM
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2300/24
2750/24
0.660
0.725
0.787
0.870
0.950
1.040
1.130
1.208
1.370
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.125
0.065
0.065
0.065
0.065
0.065
0.065
0.065
0.065
0.095
0.921
0.984
1.055
1.138
1.244
1.355
1.433
1.516
1.791
23.4
25.1
26.8
28.9
31.6
33.9
36.4
38.5
45.5
1068
1258
1462
1726
2018
2416
2881
3455
4077
1589
1872
2176
2568
3046
3595
4287
5142
6067
471
511
590
656
731
815
905
1005
1115
Nominal
O.D.
Ampacity
at Ambient
Temp. 30C
Approx.
Weight
*** Based on single conductor in free air, 30C ambient air temperature 90C conductor temperature per 2005 NEC Table 310.17
TF CABLE (SIZE) 90C DLO 2KV P-7K-268080-01-MSHA - E193954 (UL) RHW2 2KV VW-1 ST1 SUN RES (CSA) 205591 RW90 EPR 1000V -40C
FT1 FT4 TC SR OIL RES
phone: 630-406-9000
www.tfcable.com
W 2000V
CSA C22.2 No. 96-03, ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:
FEATURES
APPLICATIONS
Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101
4 CONDUCTOR
Part
Number
W2/0-4MNG-CAN
W4/0-4MNG-CAN
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
2/0 AWG
4/0 AWG
342 19x18
532 19x28
Nominal
Insulation
Thickness
inches
0.080
Nominal
O.D.
Ampacity (1)
30C
Ambient Temp.
Approx.
Weight
mm
inches
mm
Ibs/1000 ft
kgs/km
2.03
1.89
2.22
48.0
56.3
3293
4765
4901
7092
189
252
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5
(-40C) P-7K-268101-MSHA
10
www.tfcable.com
phone: 630-406-9000
2000V G-GC
Portable Power Cable 90C UL C(UL) MSHA
Mining Grade
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Grounding cond:
Ground check:
Assembly:
Jacket:
Color Code:
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Special construction for reeling and trailing
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101
3 CONDUCTOR
Part
Number
GGC2-3MNG
GGC1-3MNG
GGC1/0-3MNG
GGC2/0-3MNG
GGC4/0-3MNG
GGC350-3MNG
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG
350 MCM
259
259
266
342
532
888
7x37
7x37
19x14
19x18
19x28
37x24
Size
Ground
Ground
Check
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
AWG
AWG
inches
inches
inches
mm
Ibs/1000 ft
7
6
5
4
2
1/0
10
8
8
8
8
6
0.060
0.080
0.080
0.080
0.080
0.095
0.165
0.170
0.170
0.190
0.205
0.280
1.34
1.51
1.65
1.75
2.04
2.68
34.0
38.4
41.9
44.5
51.8
68.1
1461
1861
2256
2695
3889
6482
Nominal
O.D.
Ampacity (1)
30C Ambient
Temp.
Approx.
Weight
kgs/km
2176
2772
3360
4014
5791
9652
A
152
177
205
237
316
433
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE G-GC PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA
Jacket:
MSHA:
CSA:
Jacket: TPU
MSHA:
phone: 630-406-9000
www.tfcable.com
11
G-GC 2000V
CSA C22.2 No. 96-03, ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B 172, ASTM B 33
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Grounding cond:
Ground check:
Assembly:
Reinforcement:
Jacket:
Color Code:
Flexible strand tin copper, ASTM B 172 and C22.2 No. 96-03 table 9
Tape separator between conductor and insulation C22.2 No. 96-03 sec 4.3.4 table 4
Ethylene-propylene rubber (EPR), C22.2 No. 96-03 table 11
Tin copper, C22.2 No. 96-03 sec 5.1.4.3 and 5.1.4.4
Yellow polypropylene-insulated tin copper conductor, C22.2 No. 96-03 sec 5.1.4
Sizes 4/0 and smaller: Three power, ground check and two polyester (green mylar) taped grounding conductors cabled together;
Sizes 250 MCM and larger: Three power, ground check and two polyester (green mylar) taped grounding conductors cabled
together to form round core; Single faced rubber filled binder tape applied overall
Nylon open braid applied overall
Black extra heavy duty, integral-filled CPE thermoset compound, C22.2 No. 96-03 sec 5.1.11.2 and 4.3.9.2 table 5
black, blue, red; C22.2 No. 96-03 table 1
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Special construction for reeling and trailing
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
UL:
C(UL):
MSHA:
E207132 Oil Resistant; 90C Wet or Dry; Sunlight resistant; Oil Resistant inners
E207132 - FT1; FT5; -40C +90C
P-7K-268101
3 CONDUCTOR
Part
Number
GGC8-3MNG-CAN
GGC6-3MNG-CAN
GGC4-3MNG-CAN
GGC2-3MNG-CAN
GGC1-3MNG-CAN
GGC1/0-3MNG-CAN
GGC2/0-3MNG-CAN
GGC3/0-3MNG-CAN
GGC4/0-3MNG-CAN
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
No. of Stranding
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
133
133
259
259
259
266
342
418
532
7x19
7x19
7x37
7x37
7x37
19x14
19x18
19x22
19x28
Size
Ampacity (1)
30C Ambient
Temp.
Ground
Ground
Check
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
AWG
AWG
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
10
10
8
7
6
5
4
2
2
10
10
10
8
8
8
8
8
8
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.134
0.146
0.146
0.165
0.170
0.170
0.190
0.197
0.205
0.97
1.05
1.19
1.34
1.51
1.65
1.75
1.89
2.04
24.6
26.7
30.2
34.0
38.4
41.9
44.5
48.0
51.8
636
785
1086
1461
1861
2256
2695
3203
3889
947
1168
1617
2176
2772
3360
4014
4770
5791
65
87
114
152
177
205
237
274
316
Nominal
O.D.
Approx.
Weight
(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)
TF CABLE (SIZE) TYPE G-GC PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5
(-40C) P-7K-268101-MSHA
12
www.tfcable.com
phone: 630-406-9000
5000V / 15000V
MP-GC
CONSTRUCTION:
Conductor:
Conductor shield:
Insulation:
Insulation shield:
Grounding cond:
Ground check :
Assembly:
Reinforcement:
Jacket:
Color Code:
FEATURES
APPLICATION
APPROVALS:
MSHA:
P-7K-254064-1
CSA certified product available
Size
Power
Conductor
Size
Power
Conductor
Stranding
Ground
Check
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
Ground
AWG or MCM
No. of Stranding
AWG
AWG
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
Nominal
O.D.
Ampacity(1)
40C Ambient
Temp.
Approx.
Weight
MPGC5KV2/0-3
MPGC5KV4/0-3
2/0
4/0
19
37
3
1
0.090
0.110
0.140
1.81
2.06
46.0
52.3
2660
3760
3970
5600
243
321
MPGC5KV2/0-3-RED
2/0
19
0.090
0.110
1.81
46.0
2660
3970
243
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
inches
inches
inches
mm
0.175
0.140
2.20
2.45
55.9
62.2
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
MPGC15KV2/0-3
MPGC15KV4/0-3
Power
Conductor
Size
Power
Conductor
Stranding
Ground
AWG or MCM
No. of Stranding
AWG
2/0 AWG
4/0 AWG
19
37
Size
3
1
Ground
Check
AWG
8
Nominal
O.D.
Ampacity(1)
40C Ambient
Temp.
Approx.
Weight
Ibs./1000 ft.
3190
4310
kgs/km
4760
6430
246
325
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
phone: 630-406-9000
www.tfcable.com
13
CONSTRUCTION:
Conductor:
Conductor shield:
Insulation:
Insulation shield:
Grounding cond:
Ground check:
Assembly:
Jacket:
Color code:
FEATURES
APPLICATION
- For use up to 8000 volts when installed in ducts, conduits, open air and for direct
burial in wet and dry locations
- For semi-permanent and permanent installations in tunnels, shafts and bore holes.
- Other industrial and mining applications requiring shielding.
APPROVALS:
MSHA:
P-07-KA050003-1
MPGC8KV2/0-3-CPE
Power
Conductor
Size
Power
Conductor
Stranding
AWG or MCM
2/0 AWG
Size
Ground
Ground
Check
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
No. of Stranding
AWG
AWG
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
19
0.115
0.140
1.88
47.8
2900
4316
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
0.140
1.88
2.40
47.8
61.0
2285
4605
3400
6853
Nominal
O.D.
Approx.
Weight
MPGC15KV2-3-CPE
MPGC15KV4/0-3-CPE
Size
Power
Conductor
Size
Power
Conductor
Stranding
Ground
Ground
Check
AWG or MCM
No. of Stranding
AWG
AWG
2 AWG
4/0 AWG
7
37
6
1
0.175
Nominal
O.D.
Approx.
Weight
Power
Conductor
Resistance
at 25C
Grounding
Conductor
Resistance
at 25C
Ground Check
Conductor
Resistance
at 25C
Inductance
per length
unit
Operating
Capacitance per
length unit
Permissible
short-circuit
Current(2) (1s)
Ampacity(1)
40C
Ambient
Temp.
Maximum
Permissible
Tension
Force
AWG or MCM
/1000Ft
/1000Ft
/1000Ft
mH/1000Ft
F/1000Ft
kA
0.081
0.051
0.213
0.134
0.652
0.098
0.093
0.14
0.16
9.64
15.30
243
321
4000
6400
(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature
(2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C
www.tfcable.com
phone: 630-406-9000
2000V SHD-GC
Portable Power Cable Extra Heavy Duty EPR / NEO 90C MSHA
Mining Grade
SPECIFICATIONS & STANDARDS
CONSTRUCTION:
Conductors:
Flexible strand tinned copper conductor, ASTM B-172 and ICEA S-75-381, table 3-22
Separator:
Polyester tape between conductor and insulation. ICEA S-75-381
Insulation:
Ethylene-propylene rubber (EPR) ICEA S-75-381, table 3-22
Insulation Shield: Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Color Code:
Polyamide braid color code - black, white, red, ICEA S-75-381
Grounding Cond: Tinned copper - ICEA S-75-381 Tab. 3-25
Ground Check:
Yellow polypropylene-insulated tinned copper conductor, ICEA S-75-381 Tab. 3-22
Cable Assembly:
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Separator:
Nylon open braid applied overall
Jacket:
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, ICEA S-75-381
Tab. 3-3, 3-22, Sec. 3.21
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
MSHA:
P-07-KA060012
Power
Conductor
Size
Part
Number
Power
Conductor
Stranding
Size
AWG
AWG
10
10
10
8
8
8
8
8
8
12
12
10
10
8
6
4
3
1
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG
49
49
133
133
259
259
266
342
532
Grounding
Conductor
Ground Check
Conductor
Size
7X7
7X7
7x19
7x19
7x37
7x37
19x14
19x18
19x28
Stranding
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
No. of Wires
inches
inches
inches
mm
Ibs/1000ft
kgs/km
49
49
49
49
133
133
259
259
259
0.070
0.070
0.070
0.070
0.070
0.070
0.080
0.080
0.080
0.125
0.125
0.155
0.155
0.155
0.170
0.190
0.205
0.220
0.92
0.95
1.13
1.26
1.36
1.55
1.81
1.94
2.24
23.4
24.1
28.7
32.0
34.5
39.4
46.0
49.3
56.9
557
623
818
1076
1308
1874
2694
3301
4701
829
927
1217
1601
1947
2789
4009
4913
6996
7x7
7x7
7x7
7x7
7x19
7x19
7x37
7x37
7x37
Nominal
O.D.
Approx.
Weight
Grounding
AWG or MCM
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG
10 AWG
8 AWG
6 AWG
4 AWG
3 AWG
1 AWG
Power
Conductor
Resistance
at 25C
Grounding
Conductor
Resistance
at 25C
Ground Check
Conductor
Resistance
at 25C
/1000Ft
/1000Ft
/1000Ft
mH/1000Ft
F/1000Ft
0.679
0.118
0.107
0.101
0.097
0.092
0.088
0.09
0.11
0.13
0.14
0.16
0.19
0.436
0.274
0.172
0.109
0.0868
0.0546
1.109
0.697
0.436
0.274
0.227
0.137
Ampacity(1)
40C
Ambient
Temp.
Maximum
Permissible
Tensile Force
kA
1.90
3.03
4.80
7.65
9.64
15.30
93
122
159
211
243
321
600
950
1500
2400
3000
4800
Operating
Permissible ShortInductance
Capacitance per
Circuit
per unit length
unit length
Current(2) (1s)
(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C
phone: 630-406-9000
www.tfcable.com
15
SHD-GC 2000V
Portable Power Cable Extra Heavy Duty EPR / NEO 90C CSA MSHA
Mining Grade
ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33, CSA C22.2 No. 96-09
CONSTRUCTION:
Conductors:
Flexible strand tinned copper, ASTM B 172 and ASTM B33, C22.2 No. 96-09 sec 6.1.2 table 9
Separator:
Polyester tape between conductor and insulation
Insulation:
Ethylene-propylene rubber (EPR) C22.2 No. 96-09 sec 5.3.4 table 2 & 4
Insulation Shield: Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Color Code:
Polyamide braid color code - black, red, blue C22.2 No. 96-09 table 1
Grounding Cond: Tinned copper - C22.2 No. 96-09 sec 5.3.2
Ground Check:
Yellow polypropylene-insulated tinned copper conductor, C22.2 No. 96-09 sec 5.3.3 table 4A
Cable Assembly:
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Separator:
Nylon open braid applied overall
Jacket:
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, C22.2 No. 96-09 sec 5.3.9 table 2 & 5
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
CSA:
MSHA:
Part
Number
Power
Conductor
Stranding
Size
AWG
AWG
10
10
10
8
8
8
8
8
8
12
12
10
10
9
7
5
4
2
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG
49
49
133
133
259
259
266
342
532
Grounding
Conductor
Ground Check
Conductor
Size
7X7
7X7
7x19
7x19
7x37
7x37
19x14
19x18
19x28
Stranding
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
No. of Wires
inches
inches
inches
mm
Ibs/1000ft
kgs/km
49
49
49
49
133
133
259
259
259
0.070
0.070
0.070
0.070
0.070
0.070
0.080
0.080
0.080
0.125
0.125
0.155
0.155
0.155
0.170
0.190
0.205
0.220
0.92
0.95
1.13
1.26
1.36
1.55
1.81
1.94
2.24
23.4
24.1
28.7
32.0
34.5
39.4
46.0
49.3
56.9
557
623
818
1076
1308
1874
2694
3301
4701
829
927
1217
1601
1947
2789
4009
4913
6996
7x7
7x7
7x7
7x7
7x19
7x19
7x37
7x37
7x37
Nominal
O.D.
Approx.
Weight
Grounding
AWG or MCM
6 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG
10 AWG
6 AWG
5 AWG
4 AWG
3 AWG
1 AWG
Power
Conductor
Resistance
at 25C
Grounding
Conductor
Resistance
at 25C
Ground Check
Conductor
Resistance
at 25C
/1000Ft
/1000Ft
/1000Ft
mH/1000Ft
F/1000Ft
0.679
0.118
0.101
0.100
0.097
0.092
0.088
0.09
0.13
0.13
0.14
0.16
0.19
0.436
0.172
0.137
0.109
0.0868
0.0546
1.109
0.436
0.349
0.274
0.227
0.137
Ampacity(1)
40C
Ambient
Temp.
Maximum
Permissible
Tensile Force
kA
1.90
4.80
6.06
7.65
9.64
15.30
93
159
184
211
243
321
600
1500
1900
2400
3000
4800
Operating
Permissible ShortInductance
Capacitance per
Circuit
per unit length
unit length
Current(2) (1s)
(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C
16
www.tfcable.com
phone: 630-406-9000
5000V SHD-GC
Portable Power Cable Extra Heavy Duty EPR / NEO 90C MSHA
Mining Grade
SPECIFICATIONS & STANDARDS
CONSTRUCTION:
Conductors:
Conductor Shield:
Insulation:
Insulation Shield:
Color Code:
Grounding Cond:
Ground Check:
Cable Assembly:
Separator:
Jacket:
Flexible strand tinned copper conductor, ASTM B-172 and ICEA S-75-381, table 3-22
Extruded semi-conducting layer over conductor. ICEA S-75-381 sec. 3.14
Ethylene-propylene rubber (EPR) ICEA S-75-381, table 3-22
Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Polyamide braid color code - black, white, red, ICEA S-75-381
Tinned copper - ICEA S-75-381 Tab. 3-25
Yellow polypropylene-insulated tinned copper conductor, ICEA S-75-381 Tab. 3-22
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Single faced rubber-filled binder tape applied over core
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, ICEA S-75-381 Tab. 3-3, 3-22, Sec. 3.21
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
MSHA:
P-07-KA060012
Part
Number
SHDGC5KV4-3
SHDGC5KV2-3
SHDGC5KV1-3
SHDGC5KV1/0-3
SHDGC5KV2/0-3
SHDGC5KV4/0-3
SHDGC5KV350-3
SHDGC5KV500-3
Power
Conductor
Size
Power
Conductor
Stranding
Ground Check
Conductor
Size
Size
AWG or MCM
No. of Stranding
AWG
AWG
8
8
8
8
8
8
6
6
8
6
5
4
3
1
2/0
4/0
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG
350 MCM
500 MCM
259
259
259
266
342
532
888
1221
7x37
7x37
7x37
19x14
19x18
19x28
37x24
37x33
Grounding
AWG or MCM
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG
350 MCM
500 MCM
8 AWG
6 AWG
5 AWG
4 AWG
3 AWG
1 AWG
2/0 AWG
4/0 AWG
Stranding
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
No. of Wires
inches
inches
inches
mm
Ibs/1000ft
kgs/km
133 7x19
133 7x19
133 7x19
259 7x37
259 7x37
259 7x37
342 19x18
532 19x28
0.110
0.110
0.110
0.110
0.110
0.110
0.120
0.120
0.185
0.205
0.205
0.220
0.220
0.235
0.265
0.280
1.68
1.87
1.95
2.08
2.20
2.50
2.95
3.31
42.7
47.5
49.5
52.8
55.9
63.5
74.9
84.1
1769
2370
2660
3200
3615
5059
7700
10200
2633
3527
3959
4762
5380
7529
11458
15178
Grounding Conductor
Power
Conductor
Resistance
at 25C
/1000Ft
Grounding
Conductor
Resistance
at 25C
/1000Ft
Ground Check
Conductor
Resistance
at 25C
/1000Ft
0.274
0.172
0.137
0.109
0.0868
0.0546
0.0333
0.0233
0.697
0.436
0.349
0.274
0.227
0.137
0.0868
0.0546
0.679
0.679
0.679
0.679
0.679
0.679
0.436
0.436
Nominal
O.D.
Approx.
Weight
Inductance
per unit
length
Operating
Capacitance
per unit length
Permissible
Short-Circuit
Current(2) (1s)
Ampacity(1)
40C
Ambient Temp.
Maximum
Permissible
Tensile Force
mH/1000Ft
F/1000Ft
kA
0.107
0.101
0.100
0.097
0.092
0.088
0.081
0.078
0.11
0.13
0.13
0.14
0.16
0.19
0.24
0.28
3.03
4.80
6.06
7.65
9.64
15.30
25.31
36.18
122
159
184
211
243
321
435
536
950
1500
1900
2400
3000
4800
7900
11400
(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C
phone: 630-406-9000
www.tfcable.com
17
SHD-GC 5000V
Portable Power Cable Extra Heavy Duty EPR / NEO 90C CSA MSHA
Mining Grade
ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33, CSA C22.2 No. 96-09
CONSTRUCTION:
Conductors:
Conductor Shield:
Insulation:
Insulation Shield:
Color Code:
Grounding Cond:
Ground Check:
Cable Assembly:
Separator:
Jacket:
Flexible strand tinned copper, ASTM B 172 and ASTM B33, C22.2 No. 96-09 sec 5.3.1 table 3
Extruded semi-conducting layer over conductor. C22.2 No. 96-09
Ethylene-propylene rubber (EPR) C22.2 No. 96-09 sec 5.3.4 table 2 & 4
Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Polyamide braid color code - black, red, blue C22.2 No. 96-09 table 1
Tinned copper - C22.2 No. 96-09 sec 5.3.2
Yellow polypropylene-insulated tinned copper conductor, C22.2 No. 96-09 sec 5.3.3 table 4A
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Single faced rubber-filled binder tape applied over core
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, C22.2 No. 96-09 sec 5.3.9 table 2 & 5
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
CSA:
MSHA:
Part Number
SHDGC5KV6-3
SHDGC5KV4-3
SHDGC5KV2-3
SHDGC5KV1-3
SHDGC5KV1/0-3
SHDGC5KV2/0-3
SHDGC5KV3/0-3
SHDGC5KV4/0-3
SHDGC5KV250-3
SHDGC5KV350-3
SHDGC5KV500-3
Grounding Conductor
Power Conductor
Size
Power Conductor
Stranding
Ground Check
Conductor Size
Size
Stranding
Nominal Insulation
Thickness
Nominal Jacket
Thickness
AWG or MCM
No. of Stranding
AWG
AWG
No. of Wires
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
8
8
8
8
8
8
8
8
6
6
6
10
9
7
6
5
4
3
2
1
1/0
3/0
49
133
133
133
259
259
259
259
266
342
532
7x7
7x19
7x19
7x19
7x37
7x37
7x37
7x37
19x14
19x18
19x28
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.120
0.120
0.120
0.185
0.185
0.205
0.205
0.220
0.220
0.235
0.235
0.250
0.265
0.280
1.56
1.68
1.87
1.95
2.08
2.20
2.36
2.50
2.69
2.95
3.31
39.6
42.7
47.5
49.5
52.8
55.9
59.9
63.5
68.3
74.9
84.1
1460
1769
2370
2660
3200
3615
4300
5059
6200
7700
10200
2173
2633
3527
3959
4762
5380
6398
7529
9227
11458
15178
Permissible
Short-Circuit
Current(2) (1s)
Ampacity(1) 40C
Ambient
Temp.
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
133
259
259
259
266
342
418
532
627
888
1221
7x19
7x37
7x37
7x37
19x14
19x18
19x22
19x28
19x33
37x24
37x33
Nominal O.D.
Approx. Weight
AWG or MCM
Power Conductor
Resistance at 20C
/1000Ft
6 AWG 10 AWG
4 AWG 8 AWG
2 AWG 6 AWG
1 AWG 5 AWG
1/0 AWG 4 AWG
2/0 AWG 3 AWG
3/0 AWG 2 AWG
4/0 AWG 1 AWG
250 MCM 1/0 AWG
350 MCM 2/0 AWG
500 MCM 4/0 AWG
0.436
0.274
0.172
0.137
0.109
0.0868
0.0688
0.0546
0.0466
0.0333
0.0233
Grounding Conductor
Resistance at 20C
Ground Check
Conductor
Resistance at 20C
Inductance
per unit length
Operating
Capacitance per
unit length
/1000Ft
/1000Ft
mH/1000Ft
F/1000Ft
kA
0.679
0.679
0.679
0.679
0.679
0.679
0.679
0.679
0.436
0.436
0.436
0.132
0.119
0.112
0.108
0.105
0.099
0.098
0.094
0.089
0.085
0.082
0.08
0.09
0.10
0.11
0.12
0.14
0.14
0.16
0.18
0.21
0.24
1.90
3.03
4.80
6.06
7.65
9.64
12.15
15.30
18.16
25.31
36.18
93
122
159
184
211
243
279
321
355
435
536
600
950
1500
1900
2400
3000
3800
4800
5800
7900
11400
1.109
0.697
0.436
0.349
0.274
0.227
0.172
0.137
0.109
0.0868
0.0546
(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C
www.tfcable.com
phone: 630-406-9000
Maximum
Permissible
Tensile Force
CONSTRUCTION:
Conductors:
Flexible strand tinned copper conductor, ASTM B-172 and ICEA S-75-381, table 3-22
Conductor Shield: Extruded semi-conducting layer over conductor. ICEA S-75-381 sec. 3.14
Insulation:
Ethylene-propylene rubber (EPR) ICEA S-75-381, table 3-22
Insulation Shield: Semi-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Color Code:
Polyamide braid color code - black, white, red, ICEA S-75-381
Grounding Cond: Tinned copper - ICEA S-75-381 Tab. 3-25
Ground Check:
Yellow polypropylene-insulated tinned copper conductor, ICEA S-75-381 Tab. 3-22
Cable Assembly:
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Separator:
Single faced rubber-filled binder tape applied over core
Jacket:
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, ICEA S-75-381 Tab. 3-3, 3-22, Sec. 3.21
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
MSHA:
P-07-KA060012-1
Part
Number
Power
Conductor
Size
Power
Conductor
Stranding
Ground Check
Conductor
Size
AWG or MCM
No. of Stranding
SHDGC8KV1/0-3
SHDGC8KV2/0-3
SHDGC8KV4/0-3
1/0 AWG
2/0 AWG
4/0 AWG
266 19 x14
342 19 x18
532 19x28
SHDGC15KV2-3
SHDGC15KV1/0-3
SHDGC15KV2/0-3
SHDGC15KV4/0-3
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG
259 7x37
266 19x14
342 19x18
532 19x28
Size
Stranding
Nominal
Insulation
Thickness
AWG
AWG
No. of Wires
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
4
3
1
259
259
259
7x37
7x37
7x37
0.150
0.150
0.150
0.220
0.235
0.250
2.32
2.46
2.75
58.9
62.5
69.9
3530
4160
5590
5112
6191
8319
6
4
3
1
133
259
259
259
7x19
7x37
7x37
7x37
0.210
0.210
0.210
0.210
0.235
0.250
0.250
0.265
2.41
2.64
2.73
3.05
61.2
67.1
69.3
77.5
3505
4614
4895
6821
5216
6867
7285
10151
Grounding Conductor
Nominal
Jacket
Thickness
Nominal
O.D.
Approx.
Weight
Power
Conductor
Resistance
at 25C
Grounding
Conductor
Resistance
at 25C
Ground Check
Conductor
Resistance
at 25C
Inductance
per unit
length
Operating
Capacitance per
unit length
Permissible
Short-Circuit
Current(2) (1s)
Ampacity(1)
40C
Ambient
Temp.
Maximum
Permissible
Tensile Force
AWG or MCM
/1000Ft
/1000Ft
/1000Ft
mH/1000Ft
F/1000Ft
kA
2 AWG 6 AWG
1/0 AWG 4 AWG
2/0 AWG 3 AWG
4/0 AWG 1 AWG
0.172
0.109
0.0868
0.0546
0.679
0.122
0.113
0.107
0.101
0.09
0.10
0.11
0.13
4.80
7.65
9.64
15.30
159
211
243
321
1500
2400
3000
4800
0.436
0.274
0.227
0.137
(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C
phone: 630-406-9000
www.tfcable.com
19
ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33, CSA C22.2 No. 96-09
CONSTRUCTION:
Conductors:
Conductor Shield:
Insulation:
Insulation Shield:
Color Code:
Grounding Cond:
Ground Check:
Cable Assembly:
Separator:
Jacket:
Flexible strand tinned copper, ASTM B 172 and ASTM B33, C22.2 No. 96-09 sec 5.3.1 table 3
Extruded semi-conducting layer over conductor. C22.2 No. 96-09
Ethylene-propylene rubber (EPR) C22.2 No. 96-09 sec 5.3.4 table 2 & 4
Semi-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Polyamide braid color code - black, red, blue C22.2 No. 96-09 table 1
Tinned copper - C22.2 No. 96-09 sec 5.3.2
Yellow polypropylene-insulated tinned copper conductor, C22.2 No. 96-09 sec 5.3.3 table 4A
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Single faced rubber-filled binder tape applied over core
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, C22.2 No. 96-09 sec 5.3.9 table 2 & 5
FEATURES
APPLICATION
Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification
APPROVALS:
CSA:
MSHA:
Power
Conductor
Size
Power
Conductor
Stranding
Ground Check
Conductor
Size
Size
AWG or MCM
No. of Stranding
AWG
AWG
SHDGC8KV1-3CSA
SHDGC8KV1/0-3CSA
SHDGC8KV2/0-3CSA
1 AWG
1/0 AWG
2/0 AWG
259 7x37
266 19 x14
342 19 x18
SHDGC15KV4/0-3CSA
4/0 AWG
532 19x28
Part
Number
Stranding
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
No. of Wires
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
6
5
4
133
259
259
7x19
7x37
7x37
0.150
0.220
0.220
0.235
2.21
2.32
2.46
56.0
58.9
62.5
3300
3530
4160
4911
5112
6191
259
7x37
0.210
0.265
3.05
77.5
6821
10151
Nominal
O.D.
Approx.
Weight
Power
Conductor
Resistance
at 25C
Grounding
Conductor
Resistance
at 25C
Ground Check
Conductor
Resistance
at 25C
Inductance
per unit
length
Operating
Capacitance per
unit length
Permissible
Short-Circuit
Current(2) (1s)
Ampacity(1)
40C
Ambient
Temp.
Maximum
Permissible
Tensile Force
AWG or MCM
/1000Ft
/1000Ft
/1000Ft
mH/1000Ft
F/1000Ft
kA
1 AWG - 5 AWG
1/0 AWG 4 AWG
2/0 AWG 3 AWG
4/0 AWG 1 AWG
0.137
0.109
0.0868
0.0546
0.679
0.117
0.113
0.107
0.101
0.09
0.10
0.11
0.13
6.06
7.65
9.64
15.30
184
211
243
321
1900
2400
3000
4800
0.349
0.274
0.227
0.137
(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C
20
www.tfcable.com
phone: 630-406-9000
300V SJOOW
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES
APPLICATION
- Industrial and processing equipment, cranes and hoists, track systems, tools,
construction equipment, motors and associated machinery, garage portable
lights, battery charger and equipment exposed to oils, solvents, flame,
moisture and other electrical equipment
APPROVALS:
UL:
CSA:
MSHA:
E123366 (CPE)
1534535 (LL 103932) (CPE)
P-7K-254013 (CPE)
Part
Number
Conductor
Size
No. of
Conductors
AWG
Power
Conductor
Stranding
No. of Stranding
Nominal
Insulation
Thickness
inches
mm
Nominal Jacket
Thickness
Approx.
Weight
Ampacity (1)
30C
Ambient Temp.
mm
inches
mm
lbs/1000 ft
0.030
0.76
0.28
0.30
0.33
7.2
7.7
8.4
42
52
63
10.0
10.0
7.0
0.76
0.030
0.76
0.31
0.33
0.36
7.9
8.4
9.1
53
66
83
13.0
13.0
10.0
0.030
0.76
0.030
0.76
0.34
0.36
0.40
8.7
9.2
10.1
68
88
110
18.0
18.0
15.0
65 / 30
0.030
0.76
0.045
1.14
0.41
0.43
0.47
10.4
10.9
11.9
104
131
163
25.0
25.0
20.0
103 / 30
0.045
1.14
0.060
1.52
0.54
0.58
0.63
13.8
14.6
16.0
177
225
279
30.0
30.0
25.0
SJOOW18-2 IF
SJOOW18-3 IF
SJOOW18-4 IF
18
2
3
4
16 / 30
0.030
0.76
SJOOW16-2 IF
SJOOW16-3 IF
SJOOW16-4 IF
16
2
3
4
26 / 30
0.030
SJOOW14-2 IF
SJOOW14-3 IF
SJOOW14-4 IF
14
2
3
4
41 / 30
SJOOW12-2 IF
SJOOW12-3 IF
SJOOW12-4 IF
12
2
3
4
SJOOW10-2 IF
SJOOW10-3 IF
SJOOW10-4 IF
10
2
3
4
inches
Nominal O.D.
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) TYPE SJOOW E123366 90C SUN & WATER RES 300V CSA TYPE SJOOW 90C LL 103932 FT2
-40C P-7K-254013 MSHA
Yellow, Orange
phone: 630-406-9000
www.tfcable.com
21
SOOW 600V
Portable Cord -40C +90C UL CSA MSHA
Extra Hard Usage - High Grade Mechanical Service
UL 62/CSA-C 22.2 No 49
CONSTRUCTION:
Conductors:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES
APPLICATION
APPROVALS:
UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Power
Conductor
Size
Part
Number
No. of
Conductors
AWG
Power
Conductor
Stranding
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
Nominal
O.D.
No. of Stranding
inches
mm
inches
mm
inches
mm
Ampacity (1)
30C
Ambient Temp.
lbs/1000 ft
SOOW18-2 IF
SOOW18-3 IF
SOOW18-4 IF
18
2
3
4
16 / 30
0.030
0.76
0.060
1.52
0.34
0.36
0.39
8.6
9.1
9.8
63
74
87
10.0
10.0
7.0
SOOW16-2 IF
SOOW16-3 IF
SOOW16-4 IF
16
2
3
4
26 / 30
0.030
0.76
0.060
1.52
0.37
0.39
0.42
9.3
10.1
10.5
76
90
107
13.0
13.0
10.0
SOOW14-2 IF
SOOW14-3 IF
SOOW14-4 IF
14
2
3
4
41 / 30
0.045
1.14
0.080
2.03
0.50
0.52
0.57
12.6
13.3
14.4
137
161
192
18.0
18.0
15.0
SOOW12-2 IF
SOOW12-3 IF
SOOW12-4 IF
12
2
3
4
65 / 30
0.045
1.14
0.095
2.41
0.57
0.59
0.64
14.4
15.2
16.5
184
217
261
25.0
25.0
20.0
SOOW10-2 IF
SOOW10-3 IF
SOOW10-4 IF
10
2
3
4
104 / 30
0.045
1.14
0.095
2.41
0.62
0.65
0.70
15.6
16.5
17.8
230
281
336
30.0
30.0
25.0
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) SOOW E123366 90C SUN & WATER RES 600V CSA SOOW 90C
LL 103932 FT2 -40C P-7K-254013 MSHA
Approx.
Weight
Yellow, Orange
European harmonized dual rating
www.tfcable.com
phone: 630-406-9000
600V SOOW
UL 62/CSA-C 22.2 No 49
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES
APPLICATION
APPROVALS:
UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Part
Number
Power
Conductor
Size
No. of
Conductors
Power
Conductor
Stranding
Nominal
Insulation
Thickness
AWG
Nominal Jacket
Thickness
Nominal O.D.
Approx.
Weight
Ampacity (1)
30C
Ambient Temp.
mm
inches
mm
inches
mm
lbs/1000 ft
SOOW8-3 IF-UL/CSA
SOOW8-4 IF-UL/CSA
SOOW8-5 IF-UL/CSA
3
4
5
133 / 0.0156
0.060
1.52
0.110
0.125
0.125
2.79
3.18
3.18
0.83
0.93
1.00
21.1
23.5
25.4
452
577
683
40.0
35.0
28.0
SOOW6-3 IF-UL/CSA
SOOW6-4 IF-UL/CSA
SOOW6-5 IF-UL/CSA
3
4
5
184 / 0.0117
0.060
1.52
0.125
0.140
0.140
3.18
3.56
3.56
0.97
1.05
1.18
24.6
26.7
30.0
641
785
983
55.0
45.0
36.0
SOOW4-3 IF-UL/CSA
SOOW4-4 IF-UL/CSA
SOOW4-5 IF-UL/CSA
3
4
5
165 / 0.0156
0.060
1.52
0.140
0.155
0.155
3.56
3.94
3.94
1.13
1.25
1.31
28.7
31.8
33.2
913
1156
1318
70.0
60.0
48.0
SOOW2-3 IF-UL/CSA
SOOW2-4 IF-UL/CSA
SOOW2-5 IF-UL/CSA
3
4
5
262 / 0.0156
0.060
1.52
0.155
0.170
0.170
3.94
4.32
4.32
1.30
1.45
1.53
33.1
36.8
38.8
1287
1644
1900
95.0
80.0
64.0
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) SOOW E123366 90C SUN & WATER RES 600V CSA SOOW 90C
LL 103932 FT2 -40C P-7K-254013 MSHA
Yellow, Orange
European harmonized dual rating
phone: 630-406-9000
www.tfcable.com
23
SOOW 600V
UL 62/CSA-C 22.2 No 49
CONSTRUCTION:
Conductors:
Seprator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES
APPLICATION
APPROVALS:
MSHA: P-7K-254013
Part
Number
Power
Conductor
Size
No. of
Conductors
AWG
SOOW8-2 IF
SOOW8-3 IF
SOOW8-4 IF
SOOW8-5 IF
SOOW6-2 IF
SOOW6-3 IF
SOOW6-4 IF
SOOW6-5 IF
SOOW4-2
SOOW4-3
SOOW4-4
SOOW4-5
SOOW2-2
SOOW2-3
SOOW2-4
SOOW2-5
Power
Conductor
Stranding
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
133 / 0.0156
184 / 0.0117
165 / 0.0156
262 / 0.0156
Nominal
Insulation
Thickness
inches
0.050
0.050
0.050
0.050
mm
Nominal
Jacket
Thickness
inches
Nominal
O.D.
Approx.
Weight
Ampacity (1)
30C
Ambient Temp.
mm
inches
mm
lbs/1000 ft
16.1
17.1
18.8
20.7
258
326
410
499
40
40
35
28
1.27
0.060
1.52
0.64
0.68
0.74
0.81
1.27
0.060
0.060
0.080
0.080
1.52
1.52
2.03
2.03
0.72
0.77
0.89
0.97
18.4
19.5
22.5
24.7
353
450
607
736
55
55
45
36
2.03
0.88
0.94
1.03
1.13
22.4
23.8
26.1
28.8
540
689
876
1068
70
70
60
48
2.03
1.01
1.07
1.18
1.30
25.6
27.3
30.0
33.1
755
980
1251
1534
95
95
80
64
1.27
1.27
0.080
0.080
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE FLEXTREME (COND) (SIZE) (mm2) TYPE SOOW 600V SUNLIGHT & WATER RESISTANT 90C P-7K-254013-MSHA
24
www.tfcable.com
phone: 630-406-9000
600V SOOW
UL 62/CSA-C 22.2 No 49
CONSTRUCTION:
Conductors:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES
APPLICATION
APPROVALS:
UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Part
Number
SOOW18-5
SOOW18-6
SOOW18-7
SOOW18-8
SOOW18-10
SOOW18-12
SOOW18-14
SOOW18-16
SOOW18-20
SOOW18-24
SOOW18-30
SOOW16-5
SOOW16-6
SOOW16-7
SOOW16-8
SOOW16-9
SOOW16-10
SOOW16-12
SOOW16-14
SOOW16-16
SOOW16-20
SOOW16-24
SOOW16-30
SOOW16-37
SOOW16-40
SOOW16-52
SOOW16-60
SOOW14-5
SOOW14-6
SOOW14-7
SOOW14-8
SOOW14-10
SOOW14-12
SOOW14-16
SOOW14-20
SOOW14-24
SOOW14-30
SOOW14-37
Power
Conductor
Size
AWG
No. of
Conductors
18
5
6
7
8
10
12
14
16
20
24
30
16
5
6
7
8
9
10
12
14
16
20
24
30
37
40
52
60
14
5
6
7
8
10
12
16
20
24
30
37
Power
Conductor
Stranding
No. of Stranding
16 / 30
26 / 30
41 / 30
Nominal
Insulation
Thickness
inches
mm
0.030
0.030
0.045
inches
mm
inches
mm
lbs/1000 ft
Ampacity (1)
30C
Ambient Temp.
A
0.76
0.080
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.110
2.03
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.79
0.46
0.48
0.48
0.52
0.59
0.61
0.66
0.69
0.76
0.83
0.91
11.7
12.3
12.3
13.1
15.0
15.4
16.9
17.6
19.3
21.2
23.0
123
131
134
151
180
202
246
274
333
376
470
5.6
5.6
5.6
4.9
4.9
3.5
3.5
3.5
3.5
3.2
3.2
0.76
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.125
0.125
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
3.18
3.18
3.18
0.49
0.53
0.53
0.56
0.68
0.68
0.70
0.73
0.76
0.84
0.95
1.00
1.07
1.18
1.28
1.35
12.5
13.4
13.4
14.3
17.2
17.2
17.7
18.5
19.4
21.2
24.1
25.4
27.3
29.9
32.4
34.2
149
165
170
193
238
251
282
316
354
434
520
615
730
843
1016
1154
8.0
8.0
8.0
7.0
7.0
7.0
5.0
5.0
5.0
5.0
4.5
4.5
4.0
4.0
3.5
3.5
1.14
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.010
0.010
0.125
0.125
2.41
2.41
2.41
2.41
2.41
2.41
2.41
2.79
2.79
3.18
3.18
0.64
0.69
0.69
0.74
0.86
0.89
0.98
1.11
1.22
1.32
1.42
16.4
17.6
17.6
18.9
21.9
22.5
24.8
28.1
31.1
33.6
36.2
251
277
285
324
388
441
563
730
828
1027
1224
12.0
12.0
12.0
10.5
10.5
7.5
7.5
7.5
6.8
6.8
6.0
Nominal Jacket
Thickness
Nominal
O.D.
Approx.
Weight
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE CONTROLFLEX (COND) (SIZE) (mm2) (UL) TYPE SOOW E123366 90C SUN Color jacket:
& WATER RES 600V CSA TYPE SOOW 90C LL 103932 FT2 -40C P-7K-254013 MSHA
SOOW/H07:
Issue 7.0, July 2015
phone: 630-406-9000
Yellow, orange
European harmonized dual rating
www.tfcable.com
25
SOOW 600V
Control Cable -40C +90C UL CSA MSHA
Extra Hard Usage - High Grade Mechanical Service
UL 62/CSA-C 22.2 No 49
CONSTRUCTION:
Conductors:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES
APPLICATION
APPROVALS:
UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Part
Number
Power
Conductor
Size
No. of
Conductors
AWG
SOOW12-5
SOOW12-6
SOOW12-7
SOOW12-8
SOOW12-9
SOOW12-10
SOOW12-12
SOOW12-14
SOOW12-16
SOOW12-20
SOOW12-24
SOOW12-26
SOOW12-30
SOOW12-37
SOOW12-44
SOOW10-5
SOOW10-6
SOOW10-7
SOOW10-8
SOOW10-10
SOOW10-12
SOOW10-16
SOOW10-20
SOOW10-26
SOOW10-30
SOOW10-40
Power
Conductor
Stranding
No. of Stranding
12
5
6
7
8
9
10
12
14
16
20
24
26
30
37
44
10
5
6
7
8
10
12
16
20
26
30
40
65 / 30
103 / 30
Nominal
Insulation
Thickness
inches
0.045
0.045
Nominal Jacket
Thickness
Nominal
O.D.
Approx.
Weight
Ampacity (1)
30C
Ambient Temp.
mm
inches
mm
inches
mm
lbs/1000 ft
1.14
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.125
0.125
0.125
0.125
0.125
0.125
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
3.18
3.18
3.18
3.18
3.18
3.18
0.70
0.74
0.74
0.80
0.92
0.95
0.98
1.03
1.08
1.22
1.35
1.38
1.43
1.53
1.72
17.8
18.8
18.8
20.2
23.5
24.2
24.9
26.1
27.5
31.0
34.3
35.0
36.3
39.0
43.6
319
344
358
408
461
519
591
668
755
971
1106
1180
1327
1588
1868
1.14
0.095
0.095
0.095
0.095
0.110
0.110
0.125
0.125
0.125
0.125
0.141
2.41
2.41
2.41
2.41
2.79
2.79
3.18
3.18
3.18
3.18
3.58
0.76
0.82
0.82
0.88
1.05
1.09
1.23
1.35
1.54
1.59
1.87
19.3
20.7
20.7
22.3
26.8
27.6
31.2
34.4
39.0
40.4
47.4
409
452
474
541
686
788
1053
1304
1598
1803
2464
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE CONTROLFLEX (COND) (SIZE) (mm2) (UL) TYPE SOOW E123366 90C SUN Color jacket:
& WATER RES 600V CSA TYPE SOOW 90C LL 103932 FT2 -40C P-7K-254013 MSHA SOOW/H07:
26
www.tfcable.com
phone: 630-406-9000
Yellow, orange
European harmonized dual rating
16.0
16.0
16.0
14.0
14.0
14.0
10.0
10.0
10.0
10.0
9.0
9.0
9.0
8.0
7.0
20.0
20.0
20.0
17.5
17.5
12.5
12.5
12.5
11.3
11.3
10.0
600V SOOW
UL 62/CSA-C 22.2 No 49
CONSTRUCTION:
Conductors:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES
APPLICATION
APPROVALS:
UL: E123366
CSA:
1534535 (LL 103932)
Part
Number
Power
Conductor
Size
No. of
Conductors
AWG
Power
Conductor
Stranding
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
Nominal
O.D.
Approx.
Weight
Ampacity (1)
30C
Ambient Temp.
A
No. of Stranding
inches
mm
inches
mm
inches
mm
lbs/1000 ft
SOOW18-3 IF-105C-YEL
SOOW18-4 IF-105C-YEL
18
3
4
16 / 30
0.030
0.76
0.060
1.52
0.36
0.39
9.1
9.8
74
87
10.0
7.0
SOOW16-3 IF-105C-YEL
SOOW16-4 IF-105C-YEL
16
3
4
26 / 30
0.030
0.76
0.060
1.52
0.39
0.42
10.1
10.5
90
107
13.0
10.0
SOOW14-3 IF-105C-YEL
SOOW14-4 IF-105C-YEL
14
3
4
41 / 30
0.045
1.14
0.080
2.03
0.52
0.57
13.3
14.4
161
192
18.0
15.0
SOOW12-3 IF-105C-YEL
SOOW12-4 IF-105C-YEL
12
3
4
65 / 30
0.045
1.14
0.095
2.41
0.59
0.64
15.2
16.5
217
261
25.0
20.0
SOOW10-3 IF-105C-YEL
SOOW10-4 IF-105C-YEL
10
3
4
103 / 30
0.045
1.14
0.095
2.41
0.65
0.70
16.5
17.8
281
336
30.0
25.0
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE SUPER FLEXTREME (COND) (SIZE) (mm2) (UL) TYPE SOOW E123366 105C SUN & WATER RES 600V CSA SOOW 105C LL
103932 FT2 -50C
phone: 630-406-9000
www.tfcable.com
27
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
Stranded bare copper with ASTM B 174 and UL 62; IEC 60228
Paper tape for 12-8 AWG
EPR 90C compound class 3, table 8, HD 22.154 and UL 62
Insulated conductors are assembled round
Polyester tape for 18-8 AWG
Black CPE 90C compound class 1.4, table 11, HD 22.154, UL 62, integral fill jacket
HD 308, DIN VDE 0293-308; 3/c: green/yellow, blue, brown; 4/c: green/yellow, brown, black, grey;
FEATURES
APPLICATION
- Industrial and processing equipment, cranes and hoists, track systems, tools,
construction equipment, motors and associated machinery, garage portable
lights, battery
charger and equipment exposed to oils, solvents, flame, moisture and other
electrical equipment.
APPROVALS:
UL:
CSA:
MSHA:
BBJ:
E123366
1534535 (LL 103932)
P-7K-254013
<HAR>
Part
Number
Conductor
No. of
Size
Conductors
AWG
Power
Conductor
Stranding
No. of Stranding
Nominal Insulation
Thickness
inches
Nominal Jacket
Thickness
mm
Nominal O.D.
Approx.
Weight
Ampacity (1)
30C
Ambient Temp.
A
inches
mm
inches
mm
lbs/1000 ft
SOOW/H07RN-F18-3
SOOW/H07RN-F18-4
18
3/C
4/C
30 / 0.197
0.063 / 0.060
0.085 / 0.080
1.60 / 1.52
2.16 / 2.03
0.400
0.476
10.2
12.1
84
96
7.0
5.6
SOOW/H07RN-F16-3
SOOW/H07RN-F16-4
16
3/C
4/C
30 / 0.248
0.070 / 0.067
0.085 / 0.080
1.78 / 1.70
2.16 / 2.03
0.449
0.516
11.4
13.1
99
125
10.0
8.0
SOOW/H07RN-F14-3
SOOW/H07RN-F14-4
14
3/C
4/C
47 / 0.248
0.085 / 0.080
2.16 / 2.03
2.54 / 2.41
0.594
0.671
15.1
17.0
183
216
15.0
12.0
SOOW/H07RN-F12-3
SOOW/H07RN-F12-4
12
3/C
4/C
51 / 0.297
0.100 / 0.095
2.54 / 2.41
0.681
0.736
17.3
18.7
249
300
20.0
16.0
SOOW/H07RN-F10-3
SOOW/H07RN-F10-4
10
3/C
4/C
77 / 0.297
0.100 / 0.095
2.54 / 2.41
0.724
0.791
18.4
20.1
304
366
25.0
20.0
SOOW/H07RN-F8-3
SOOW/H07RN-F8-4
3/C
4/C
74 / 0.397
0.125 / 0.120
3.43 / 3.30
3.56 / 3.43
0.902
0.984
22.9
25.0
537
651
40.0
35.0
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) SOOW E123366 90C SUN & WATER RES 600V CSA SOOW 90C LL 103932 FT2 -40C
P-7K-254013 MSHA TF KABLE 3 BBJ <HAR> H07RN-F ROHS
28
www.tfcable.com
phone: 630-406-9000
CONSTRUCTION:
Conductors:
Separator:
Jacket:
FEATURES
APPLICATION
- For use in accordance with NEC Articles 520, 525 and 530,
indoor and outdoor locations
- Flame test: meets VW-1, MSHA
- Excellent flexibility, resistance to oil, solvents, ozone, aging and abrasion
- Suitable for continuous submersion in water
- Temperature range: -35C to +105C
- P
ortable power and lighting applications in the entertainment industry
including motion picture, television, theatres, stages and similar locations
APPROVALS:
UL:
C(UL):
Part
Number
STAGE6
STAGE4
STAGE2
STAGE1
STAGE1/0
STAGE2/0
STAGE3/0
STAGE4/0
STAGE6-GRN
Power
Conductor
Stranding
AWG
Nominal Jacket
Thickness
Nominal O.D.
Approx. Weight
Ampacity(1)
No. of Stranding
inches
mm
inches
mm
lbs/1000 ft
kgs/km
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
258 / 30
410 / 30
649 / 30
815 / 30
1032 / 30
1287 / 30
1622 / 30
2052 / 30
0.095
0.095
0.106
0.136
0.136
0.136
0.136
0.136
2.41
2.41
2.69
3.45
3.45
3.45
3.45
3.45
0.371
0.430
0.509
0.611
0.672
0.697
0.777
0.803
9.4
10.9
12.9
15.5
17.1
17.7
19.7
20.4
131
189
285
379
463
549
674
814
195
282
424
564
689
816
1003
1212
105
140
190
220
260
300
350
405
6 AWG
258 / 30
0.095
2.41
0.371
9.4
131
195
105
(1) Ampacities are based on single conductor in free air, 30C ambient air temperature 90C conductor operating temperature per Table 400-5 (B) of the 2008 NEC
TF CABLE (UL) E228208 (SIZE) TYPE SC 105C -35C MAX AMPS NEC TABLE 400-5B
FOR 90C 600V WATER RES. OIL RES. 60C E207132 C(UL) TYPE PPC FT5
phone: 630-406-9000
www.tfcable.com
29
CONSTRUCTION:
Conductor:
Separator:
Insulation:
Jacket:
FEATURES
APPLICATION
- UL listed RHH/RHW-2/USE-2
- Rated 90C dry and wet
- Ozone, sunlight, oil, grease, weather, water, chemical
and abrasion resistant
- VW-1, SUN RES, FOR CT USE for black
jacket sizes 1/0 AWG and larger
APPROVALS:
UL:
E232192 - EPR / CPE RHW-2 90C wet or dry, Sunlight resistant VW-1 for CT use 1/0 & larger
Part
Number
USE2-14
USE2-12
USE2-10
USE2-8
USE2-6
USE2-4
USE2-2
USE2-1/0
USE2-2/0
USE2-4/0
USE2-250
USE2-350
USE2-500
USE2-750
USE2-1000
USE2-8-GRN
USE2-6-WHT
USE2-6-RED
Power
Conductor
Size
Power
Conductor
Stranding
Conductor
Diameter
Nominal
Insulation
Thickness
Nominal
Jacket
Thickness
AWG
or MCM
inches
inches
inches
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
750 MCM
1000 MCM
7x0.024
7x0.031
7x0.039
7x0.048
7x0.061
7x0.077
7x0.097
19x0.074
19x0.084
19x0.106
37x0.082
37x0.097
37x0.116
61x0.111
61x0.128
0.072
0.091
0.116
0.146
0.183
0.231
0.292
0.373
0.419
0.528
0.575
0.681
0.813
0.980
1.152
0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080
8 AWG
6 AWG
6 AWG
7x0.048
7x0.061
7x0.061
0.146
0.183
0.183
0.045
Ampacity(1)
Approx.
40C
Weight Ambient Temp.
Cable Diameter
Minimum
Approx.
Maximum
inches
mm
inches
mm
inches
mm
Ibs/
1000 ft
0.015
0.015
0.015
0.015
0.030
0.030
0.030
0.045
0.045
0.045
0.065
0.065
0.065
0.065
0.065
0.161
0.185
0.205
0.268
0.335
0.382
0.441
0.559
0.602
0.717
0.827
0.929
1.055
1.264
1.413
4.10
4.70
5.20
6.80
8.50
9.70
11.20
14.20
15.30
18.20
21.00
23.60
26.80
32.10
35.90
0.165
0.189
0.213
0.276
0.346
0.394
0.453
0.575
0.619
0.736
0.850
0.957
1.088
1.303
1.457
4.20
4.80
5.40
7.00
8.80
10.0
11.50
14.60
15.73
18.70
21.60
24.30
27.64
33.10
37.0
0.177
0.205
0.228
0.299
0.374
0.425
0.488
0.622
0.669
0.795
0.917
1.031
1.177
1.406
1.575
4.50
5.20
5.80
7.60
9.50
10.80
12.40
15.80
17.00
20.20
23.30
26.20
29.90
35.70
40.00
24
34
49
79
124
179
260
420
513
774
956
1290
1798
2686
3463
25
32
47
83
109
145
192
258
298
400
445
552
695
898
1076
0.015
0.030
0.030
0.268
0.335
0.335
6.80
8.50
8.50
0.276
0.346
0.346
7.00
8.80
8.80
0.299
0.374
0.374
7.60
9.50
9.50
79
124
124
83
109
109
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
30
www.tfcable.com
phone: 630-406-9000
CONSTRUCTION:
Conductors:
Separator:
Jacket:
Color of jacket:
FEATURES
APPLICATION
Excellent flexibility
Ozone, sun, weather resistant
Rated and flexible at 40C
Oil resistant
Heat resistant at 105C
Part
Number
WC6
WC4
WC2
WC1
WC1/0
WC2/0
WC3/0
WC4/0
WC250
WC350
WC500
WC6-RED
WC4-RED
WC2-RED
WC1-RED
WC1/0-RED
WC2/0-RED
WC3/0-RED
WC4/0-RED
Maximum
Direct Current
Resistance
20C /km
Power
Conductor
Size
Power
Conductor
Stranding
Nominal
Insulation
Thickness
AWG or MCM
No. of Stranding
inches
inches
mm
Ibs/1000 ft
kgs/km
/km
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
253/30
403/30
636/30
798/30
1016/30
1261/30
1590/30
2007/30
2399/30
3327/30
4746/30
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.319
0.366
0.429
0.508
0.555
0.598
0.673
0.716
0.866
0.953
1.130
8.1
9.3
10.9
12.9
14.1
15.2
17.1
18.2
22.0
24.2
28.7
115
169
255
303
396
482
595
734
907
1203
1734
171
252
379
451
589
719
887
1092
1349
1790
2580
1.38
0.865
0.549
0.436
0.345
0.276
0.219
0.173
0.147
0.106
0.0743
133
179
237
284
327
377
449
514
577
719
908
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
253/30
403/30
636/30
798/30
1016/30
1261/30
1590/30
2007/30
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.319
0.366
0.429
0.508
0.555
0.598
0.673
0.716
8.1
9.3
10.9
12.9
14.1
15.2
17.1
18.2
115
169
255
303
396
482
595
734
171
252
379
451
589
719
887
1092
1.38
0.865
0.549
0.436
0.345
0.276
0.219
0.173
133
179
237
284
327
377
449
514
Nominal
O.D.
Approx.
Weight
Ampacity
40C Ambient
Temp.
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
TF CABLE (SIZE) ARC WELDING CABLE 600V OIL RESISTANT -40C +105C
Conductor:
Class M (AWG 34) stranding
Jacket:
Neoprene
CSA: 1101275 -FT2; Oil Resistant (Optional)
Neoprene is a registered trademark of DuPont
phone: 630-406-9000
www.tfcable.com
31
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Jacket:
Color Code:
FEATURES
APPLICATION
Power
Conductor
Size
No. of
Conductors
AWG
DC10-5
10
Nominal
Insulation
Thickness
Power
Conductor Stranding
Nominal
Jacket
Thickness
Nominal
O.D.
Approx.
Weight
Ampacity (1)
40C
Ambient Temp.
inches
mm
inches
mm
inches
mm
Ibs./1000 ft.
104 / 0.01
0.045
1.14
0.155
3.94
0.91
23.1
545
20.0
(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature
STANDARD PRINT LEGEND: TF CABLE FLEXTREME (SIZE) REMOTE CONTROL & DRILL CORD 600V 07-KA050015-MSHA
According to ICEA S-97-682, ICEA S-75-381/NEMA WC-58, ASTM B172, ASTM B 33, UL 1072
CONSTRUCTION:
Conductors:
Separator:
Insulation:
Jacket:
Flexible strand tin coated copper, ASTM B-172 and ICEA S-75-381
Synthetic semi-conducting tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR), UL 1072
Red heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.22
FEATURES
APPLICATION
Excellent flexibility
Water resistant
Rated and flexible at 40C to +90C
Ozone sunlight oil, grease, weather, chemical resistant
Part
Number
Power Conductor
Size
Conductor
Stranding
AWG / MCM
JC2
JC1/0
JC2/0
JC4/0
JC350
JC500
2
1/0
2/0
4/0
350
500
259x0.0159
414x0.0159
522x0.0159
829x0.0159
1361x0.0159
1921x0.0159
Nominal Insulation
Thickness
Nominal Jacket
Thickness
Nominal
O.D.
Approx.
Weight
inches
inches
inches
mm
Ibs/1000 ft
kgs/km
Ohm/1000 ft
0.175
0.175
0.175
0.175
0.175
0.175
0.080
0.080
0.080
0.080
0.080
0.080
0.820
0.905
0.997
1.140
1.305
1.410
20.8
23.0
25.3
29.0
33.1
35.8
480
639
747
1051
1584
2082
714
951
1112
1564
2357
3099
195
255
293
389
543
678
0.2122 + j0.025
0.1332 + j0.022
0.1059 + j0.022
0.0662 + j0.019
0.0405 + j0.016
0.0284 + j0.014
(1) Ampacity and Impedance Free air measured; Based on continuous duty at 90C conductor temperature
www.tfcable.com
Impedance (1)
CONSTRUCTION:
Conductors:
Jacket:
FEATURES
APPLICATION
- T
ransparent jacket provides easy confirmation of continuity and ease
of troubleshooting. Extremely flexible stranding for ease of bending
and installation
- A
transparent PVC jacketed flexible cable used for grounding jumpers installed
temporarily for protective grounding of de-energized circuits
Part Number
Power Conductor
Size
Power Conductor
Stranding
AWG
inches
mm
inches
mm
lbs/1000 ft
1323 / 0.010
2107 / 0.010
0.110
0.110
2.79
2.79
0.710
0.850
18.03
21.59
530
799
GRD-CLR2/0-1
GRD-CLR4/0-1
2/0 AWG
4/0 AWG
Nominal Insulation
Thickness
Nominal
O.D.
Approx.
Weight
kgs/km
790
1190
CONSTRUCTION:
Conductors:
Plain annealed copper stranded wires ASTM B-172 class K
Separator:
Polyester tape over conductor
Jacket:
Flame retardant, oil resistant, synthetic thermosetting CPE compound UL 1581 table 50.23
Color of Jacket: Yellow
Maximum Bending Radius: 6xD; D-overall diameter of cable
FEATURES
APPLICATION
- CPE jacket is flame retardant and oil resistant, providing added cable
protection. Extremely flexible stranding for ease of bending and
installation.
Nominal Cross-sectional
Area of Conductor
Number of Wires in
Conductor
Nominal Thickness
of Jacket
Approximate Overall
Diameter
Approximate Weight
AWG
inches
inches
lbs/1000ft
GRDCPE-YEL2/0-1
GRDCPE-YEL4/0-1
1323 / 0.010
2107 / 0.010
0.106
0.110
0.685
0.839
558
813
TF CABLE (size) 600V GROUNDING CABLE mfg. acc to ASTM F855 type I
phone: 630-406-9000
www.tfcable.com
33
TF SAP INDEX
TYPE W 1/C 2000V RHH/RHW-2 - PAGE 1
TF SAP INDEX
TF CABLE P/N
TF SAP INDEX
W8-1X
G-012327
W3/0-5
G-012423
W6-1X
G-012328
W4/0-5
G-012424
W4-1X
G-012330
W6-6
G-012425
W2-1X
G-012331
W1-1X
G-012333
W1/0-1X
G-012336
W2/0-1X
G-012337
W3/0-1X
G-012342
W4/0-1X
G-012347
W250-1X
G-012350
W350-1X
G-012352
W500-1X
G-012354
TF SAP INDEX
GGC8-3
G-004999
GGC6-3
G-005002
GGC4-3
G-005006
GGC2-3
G-005012
GGC1-3
G-005018
GGC1/0-3
G-005021
GGC2/0-3
G-005028
GGC3/0-3
G-005032
GGC4/0-3
G-005038
TF CABLE P/N
TF SAP INDEX
W8-2
G-012356
GGC250-3
G-005041
W6-2
G-012357
GGC350-3
G-005044
W4-2
G-012358
GGC500-3
G-005049
W2-2
G-012359
TF SAP INDEX
TF CABLE P/N
TF SAP INDEX
G8-4
G-004979
W8-3
G-012363
G6-4
G-024691
W6-3
G-012365
G4-4
G-004983
W4-3
G-012366
G2-4
G-004984
W2-3
G-012367
W1-3
G-012368
G1-4
G-004986
W1/0-3
G-012369
G1/0-4
G-004987
W2/0-3
G-012370
G2/0-4
G-004989
W3/0-3
G-012371
G3/0-4
G-004990
W4/0-3
G-012372
G4/0-4
G-004991
W250-3
G-012373
G250-4
G-004992
W350-3
G-012374
G350-4
G-004993
W500-3
G-012375
G500-4
G-004995
TF SAP INDEX
W8-4
G-012377
W6-4
G-012378
W4-4
G-012383
W2-4
G-012391
TF SAP INDEX
DLO14
G-011508
DLO12
G-011516
DLO10
G-011517
DLO8
G-011519
DLO6
G-011521
W1-4
G-012396
W1/0-4
G-012397
DLO4
G-011523
W2/0-4
G-012399
DLO2
G-011525
W3/0-4
G-012405
DLO1
G-011526
W4/0-4
G-012407
DLO1/0
G-011527
W250-4
G-012410
W350-4
G-012412
DLO2/0
G-011529
W500-4
G-012414
DLO3/0
G-011530
DLO4/0
G-011532
DLO262
G-011534
34
TF CABLE P/N
TF CABLE P/N
TF SAP INDEX
DLO313
G-011536
W8-5
G-012415
DLO373
G-011538
W6-5
G-012416
DLO444
G-011542
W4-5
G-012418
DLO535
G-011545
W2-5
G-012419
DLO646
G-011548
W1-5
G-012420
DLO777
G-011549
W1/0-5
G-012421
DLO929
G-011550
W2/0-5
G-012422
DLO1111
G-011551
www.tfcable.com
phone: 630-406-9000
TF SAP INDEX
TYPE SHD-GC 5000V - CONTINUED
TF SAP INDEX
TF CABLE P/N
TF SAP INDEX
W2/0-4MNG-CSA
G-012402
SHDGC5KV2/0-3
G-005095
W4/0-4MNG-CSA
G-012408
SHDGC5KV4/0-3
G-005098
SHDGC5KV350-3
G-005100
SHDGC5KV500-3
G-005102
TF SAP INDEX
GGC2-3MNG
G-005014
GGC1-3MNG
G-005016
TF CABLE P/N
TF SAP INDEX
GGC1/0-3MNG
G-005024
SHDGC5KV2-3CSA
G-005088
GGC2/0-3MNG
G-005026
SHDGC5KV1/0-3CSA
G-005093
GGC4/0-3MNG
G-005036
SHDGC5KV2/0-3CSA
G-005096
GGC350-3MNG
G-005046
TF SAP INDEX
TF CABLE P/N
TF SAP INDEX
SHDGC8KV1/0-3
G-005115
GGC8-3MNG-CSA
G-005000
SHDGC8KV2/0-3
G-005118
GGC6-3MNG-CSA
G-005005
SHDGC8KV4/0-3
G-005129
GGC4-3MNG-CSA
G-005010
SHDGC15KV2-3
G-005138
GGC2-3MNG-CSA
G-005013
SHDGC15KV1/0-3
G-005139
GGC1-3MNG-CSA
G-005020
GGC1/0-3MNG-CSA
G-005022
SHDGC15KV2/0-3
G-005140
GGC2/0-3MNG-CSA
G-005030
SHDGC15KV4/0-3
G-005142
GGC3/0-3MNG-CSA
G-005035
GGC4/0-3MNG-CSA
G-005039
TF SAP INDEX
MPGC5KV2/0-3
G-018394
MPGC5KV4/0-3
G-018395
MPGC5KV2/0-3-RED
G-020116
MPGC15KV2/0-3
G-018401
MPGC15KV4/0-3
G-018404
TF SAP INDEX
MPGC8KV2/0-3-CPE
G-004618
MPGC15KV2-3-CPE
G-004624
MPGC15KV4/0-3-CPE
G-004622
TF SAP INDEX
SHDGC8KV1-3CSA
G-005111
SHDGC8KV1/0-3CSA
G-005114
SHDGC8KV2/0-3CSA
G-005117
SHDGC15KV4/0-3CSA
G-005143
TF SAP INDEX
SJOOW18-2 IF
G-020710
SJOOW18-3 IF
G-020913
SJOOW18-4 IF
G-021009
SJOOW16-2 IF
G-012668
SJOOW16-3 IF
G-012672
SJOOW16-4 IF
G-012678
SJOOW14-2 IF
G-012669
SJOOW14-3 IF
G-012673
TF CABLE P/N
TF SAP INDEX
SJOOW14-4 IF
G-012679
SHDGC2KV6-3
G-005052
SJOOW12-2 IF
G-012670
SHDGC2KV4-3
G-005056
SJOOW12-3 IF
G-012674
SHDGC2KV2-3
G-005060
SHDGC2KV1/0-3
G-005067
SJOOW12-4 IF
G-012680
SHDGC2KV2/0-3
G-005071
SJOOW10-2 IF
G-012671
SHDGC2KV4/0-3
G-005077
SJOOW10-3 IF
G-012675
SJOOW10-4 IF
G-012681
TF SAP INDEX
SHDGC2KV6-3CSA
G-005053
SHDGC2KV2-3CSA
G-005059
SHDGC2KV1-3CSA
G-005066
SHDGC2KV1/0-3CSA
G-005069
SHDGC2KV2/0-3CSA
G-005075
SHDGC2KV4/0-3CSA
G-005078
TF SAP INDEX
SOOW18-2 IF
G-021660
SOOW18-3 IF
G-012632
SOOW18-4 IF
G-021117
SOOW16-2 IF
G-012628
SOOW16-3 IF
G-012633
SOOW16-4 IF
G-012639
SOOW14-2 IF
G-012629
SOOW14-3 IF
G-012635
SOOW14-4 IF
G-012640
TF CABLE P/N
TF SAP INDEX
SHDGC5KV4-3
G-005086
SHDGC5KV2-3
G-005087
SOOW12-2 IF
G-012630
SHDGC5KV1-3
G-005091
SOOW12-3 IF
G-012636
SHDGC5KV1/0-3
G-005092
SOOW12-4 IF
G-012641
phone: 630-406-9000
www.tfcable.com
35
TF SAP INDEX
TYPE SOOW 600V PORTABLE CORD - CONTINUED
TF SAP INDEX
TF CABLE P/N
TF SAP INDEX
SOOW10-2 IF
G-012631
SOOW16-20
G-012320
SOOW10-3 IF
G-012637
SOOW16-24
G-021025
SOOW10-4 IF
G-012642
SOOW16-30
G-012323
SOOW16-37
G-012324
SOOW16-40
G-021681
SOOW16-52
G-021682
SOOW16-60
G-021683
SOOW14-5
G-012297
SOOW14-6
G-012303
SOOW14-7
G-012305
SOOW14-8
G-012310
SOOW14-10
G-018949
SOOW14-12
G-012314
SOOW14-16
G-012318
SOOW14-20
G-020946
SOOW14-24
G-021684
SOOW14-30
G-019879
SOOW14-37
G-012325
SOOW12-5
G-021685
SOOW12-6
G-020905
G-012307
TF SAP INDEX
SOOW8-3 IF-UL/CSA
G-021339
SOOW8-4 IF-UL/CSA
G-012643
SOOW8-5 IF-UL/CSA
G-020911
SOOW6-3 IF-UL/CSA
G-019893
SOOW6-4 IF-UL/CSA
G-012644
SOOW6-5 IF-UL/CSA
G-012646
SOOW4-3 IF-UL/CSA
G-012638
SOOW4-4 IF-UL/CSA
G-021662
SOOW4-5 IF-UL/CSA
G-021663
SOOW2-3 IF-UL/CSA
G-021666
SOOW2-4 IF-UL/CSA
G-021667
SOOW2-5 IF-UL/CSA
G-021668
TF SAP INDEX
SOOW8-2 IF
G-012661
SOOW12-7
SOOW8-3 IF
G-012663
SOOW12-8
G-012311
SOOW8-4 IF
G-012664
SOOW12-9
G-019864
SOOW8-5 IF
G-012666
SOOW12-10
G-020728
SOOW6-2 IF
G-021912
SOOW12-12
G-012315
SOOW6-3 IF
G-021566
SOOW12-14
G-021686
SOOW6-4 IF
G-012665
SOOW12-16
G-012319
SOOW6-5 IF
G-012667
SOOW12-20
G-012321
SOOW4-2
G-022773
SOOW12-24
G-020901
SOOW4-3
G-012281
SOOW12-26
G-019839
SOOW4-4
G-012294
SOOW12-30
G-018952
SOOW4-5
G-012300
SOOW12-37
G-012326
SOOW2-2
G-021916
SOOW12-44
G-021687
SOOW2-3
G-012282
SOOW10-5
G-021688
SOOW2-4
G-012295
SOOW10-6
G-020104
SOOW2-5
G-012301
SOOW10-7
G-012308
SOOW10-8
G-012312
SOOW10-10
G-019809
SOOW10-12
G-021691
SOOW10-16
G-019834
SOOW10-20
G-012322
SOOW10-26
G-021692
SOOW10-30
G-021694
SOOW10-40
G-021696
36
TF CABLE P/N
TF CABLE P/N
TF SAP INDEX
SOOW18-5
G-021669
SOOW18-6
G-020706
SOOW18-7
G-021670
SOOW18-8
G-021672
SOOW18-10
G-021676
SOOW18-12
G-012313
SOOW18-14
G-012316
SOOW18-16
G-019887
TF CABLE P/N
TF SAP INDEX
SOOW18-20
G-020708
SOOW18-24
G-021677
SOOW18-3 IF-105C-YEL
G-012651
SOOW18-30
G-021679
SOOW18-4 IF-105C-YEL
G-012656
SOOW16-5
G-012296
SOOW16-3 IF-105C-YEL
G-012652
SOOW16-6
G-020709
SOOW16-4 IF-105C-YEL
G-012657
SOOW16-7
G-012304
SOOW14-3 IF-105C-YEL
G-012653
SOOW16-8
G-020909
SOOW16-9
G-021680
SOOW14-4 IF-105C-YEL
G-012658
SOOW16-10
G-020908
SOOW12-3 IF-105C-YEL
G-012654
SOOW16-12
G-021338
SOOW12-4 IF-105C-YEL
G-012659
SOOW16-14
G-020727
SOOW10-3 IF-105C-YEL
G-012655
SOOW16-16
G-012317
SOOW10-4 IF-105C-YEL
G-012660
www.tfcable.com
phone: 630-406-9000
TF SAP INDEX
TYPE ARC-WELDING CABLE 600V - CONTINUED
TF CABLE P/N
TF SAP INDEX
WC4-RED
G-012896
WC2-RED
G-012899
WC1-RED
G-012906
WC1/0-RED
G-012912
WC2/0-RED
G-012920
WC3/0-RED
G-012929
WC4/0-RED
G-012934
TF CABLE P/N
TF SAP INDEX
SOOW/H07RN-F18-3
G-012544
SOOW/H07RN-F18-4
G-012550
SOOW/H07RN-F16-3
G-012546
SOOW/H07RN-F16-4
G-012552
SOOW/H07RN-F14-3
G-012547
SOOW/H07RN-F14-4
G-012553
SOOW/H07RN-F12-3
G-020045
SOOW/H07RN-F12-4
G-012554
SOOW/H07RN-F10-3
G-012548
TF CABLE P/N
TF SAP INDEX
SOOW/H07RN-F10-4
G-012555
SOOW/H07RN-F8-3
G-012549
DC10-5
G-012528
SOOW/H07RN-F8-3
G-012556
TF SAP INDEX
STAGE6
G-012512
STAGE4
G-012513
STAGE2
G-012514
STAGE1
G-012515
STAGE1/0
G-021032
STAGE2/0
G-012516
STAGE3/0
G-021508
STAGE4/0
G-012517
STAGE6-GRN
G-012511
TF SAP INDEX
USE2-14
G-005799
USE2-12
G-005800
USE2-10
G-005801
USE2-8
G-005803
USE2-6
G-005805
UDE2-4
G-005809
USE2-2
G-005811
USE2-1/0
G-005812
USE2-2/0
G-005814
USE2-4/0
G-005816
USE2-250
G-005818
USE2-350
G-005819
USE2-500
G-005820
USE2-750
G-005821
USE2-1000
G-005822
USE2-8-GRN
G-005804
USE2-6-WHT
G-005806
USE2-6-RED
G-005807
TF SAP INDEX
JC2
G-012682
JC1/0
G-012683
JC2/0
G-012684
JC4/0
G-012685
JC350
G-021686
JC500
G-012687
TF SAP INDEX
GRD-CLR2/0-1
G-008654
GRD-CLR4/0-1
G-008655
TF SAP INDEX
GRDCPE-YEL2/0-1
G-023987
GRDCPE-YEL4/0-1
G-023988
MSHA
TF SAP INDEX
WC6
G-012890
WC4
G-012894
WC2
G-012904
WC1
G-012910
WC1/0
G-012917
WC2/0
G-012927
WC3/0
G-012931
WC4/0
G-012933
WC250
G-012941
WC350
G-012943
WC500
G-012945
WC6-RED
G-012886
phone: 630-406-9000
www.tfcable.com
37
38
www.tfcable.com
phone: 630-406-9000
Product Warranty
Tele-Fonika Cable Americas, a wholly owned subsidiary of Tele-Fonika Kable, warrants that the cable will:
Be free from defects in material and workmanship
Conform fully to published Tele-Fonika specifications, or to the specifications as otherwise agreed and confirmed by Tele-Fonika in writing
Meet all applicable independent governing standards required for the listing and for the intended application
Warranty Duration
Warranty period is 12 months from date of installation not to exceed 18 months from date of Tele-Fonika invoice.
Warranty Conditions
Liability covers only defects inherent in the product.
Product installation and claim must have been completed prior to the expiration of the warranty period.
User must resolve all non-related causes prior to claim.
User must provide verification that products received proper transporting, storing, placing and installation in accordance with generally accepted methods provided for in standards, electrical
codes and trade procedures, with respect to the purpose of the product specified by the manufacturer.
Cable repair or replacement will be performed only after TF Kable has reviewed and verified the claim prior to removal, replacement or repair of defective product.
In instances of a groundless warranty claim, customer shall be obliged to pay the costs incurred by TF Kable. A groundless warranty is defined as a situation where the defect does not
exist or the defect has been created by conditions not related to the product.
Claim Procedure
Claim must have accompanying documentation proving product purchase related to the warranty including quantity, packing slip, place and date of purchase.
Warranty claim must be conveyed to the immediate supplier of the product or to TF Kable if supplied directly.
Warranty claim must contain a description of the revealed defect.
If claim is prior to installation, the user must provide a sample of the defective product to TF Kable.
If claim is after installation user shall provide TF Kable free and easy access to the product.
User must properly secure the product or place of installation where the defects are revealed and let TF Kable inspect the product and all receiving and installation documents.
The warranty notice shall be directed at the following address:
TELE-FONIKA CABLE AMERICAS
555 Remington Blvd
Bolingbrook, IL 60440
USA
Warranty Remedy
Upon an accepted warranty claim the company will repair or replace the defective product at its discretion.
Upon an accepted warranty claim the defective product shall be the property of the Warrantor and returned.
Warranty Exclusions
Warranty does not cover non-related products or causes.
Warranty does not cover using a product not in accordance to its designed purpose, features or rules of use.
Warranty does not cover any repairs, adaptation or changes in construction performed by persons other than Warrantor.
Warranty limitations
This warranty is exclusive and in lieu of all other warranties, whether express or implied, or statutory, including, but not by way of limitation, any warranty of merchantability or fitness for any particular
purpose, non-infringement or any other matter. The remedies provided for in the preceding paragraphs shall constitute the sole recourse of end-user against Tele-Fonika Cable for breach of any
obligations to end-user, whether the claim is made in tort or in contract, including claims based on breach of warranty, negligence, strict liability, fraud, misrepresentation, or otherwise. In no event
shall Tele-Fonika Cable be liable for special, indirect, incidental or consequential damages (regardless of the form of action, whether in contract or in tort, including negligence), including, without
limitation, lost profits or economic damage arising out of the failure. Nor shall the liability of Tele-Fonika Cable for any claims or damage arising out of or connected with this warranty or the
manufacture, sale, delivery, installation or use of the products exceed the purchase price of the products and the installation.
www.tfcable.com
39