Control Circuit and Load Protection
Control Circuit and Load Protection
qxd
4/25/2008
1:12 PM
Page 7-1
!
Page 7-2
Page 7-6
Bulletin 1489 Circuit Breaker with UL 489 and CSA Approval and Approval for IEC/EN 60947-2, IEC
Applications ..............................................................................................................................................................................................
Page 7-15
Page 7-29
Page 7-31
Page 7-33
Page 7-36
Page 7-39
1
2
3
4
5
6
7
8
9
10
11
12
13
7-1
overview.qxd
4/25/2008
1:13 PM
Page 7-2
Bulletin 1492
!
1
Bulletin
Type
2
3
480Y/277V AC
240V AC
For Class CC
Fuse
0.525 A
0.540 A
30 A
Features
Certifications
Maximum
Voltage Rating
480Y/277V AC
4
5
1489
Shock
60 A
30 A
UR, CSA
600V AC/DC
30 A
32 A
690V AC
NA
NA
Tripping
Characteristic
C Curve: 510
D Curve: 1020
NA
NA
-4...+130 F (20+55 C)
-4...+130 F (20+55 C)
Nylon
Nylon
Operating
Temperature
Housing
Material
Leakage
Current with
Indicator LED
Wire Size
11
30 A
For Midget
Fuse
10
40 C (UL/CSA)
30 C (IEC)
Vibration
140F
For Class CC
For IEC 10 x 38
Fuse or Midget
mm Fuse
Fuse
Tripping
Characteristic
Reference
Temperature
7
8
1492-FB
Interrupt
Rating
Product
Selection
110600V
AC/DC or
1272V AC/DC
110600V AC/DC
2.0 mA
10 kA @ 240V AC and
480Y/277V AC (UL/CSA)
200 kA
50 kA
200 kA - Class CC
100 kA - Midget
10 kA @ 240V AC and
480Y/277V AC (UL/CSA)
Fuse dependent
Fuse dependent
Page 7-15
Page 7-29
Page 7-31
12
13
Visit our website: www.ab.com/catalogs
7-2
110600V
AC/DC or
1272V AC/DC
overview.qxd
4/25/2008
1:13 PM
Page 7-3
Bulletin 1492
!
1
Bulletin
Type
Features
1492-MC
1492-MCGA, -MCEA
1492-SP
Number of Poles
Maximum Voltage
120/240V AC
240V AC
120/240V AC 60 Hz
480Y/277V AC
1-pole 48V DC
2-pole 125V DC
Tripping Characteristic
Reference Temperature
40 C
40 C
25 C
Tripping Characteristic
UL/CSA Standard
B Curve 3...5 In
C Curve 5...10 In
D Cruve 10...20 In
UL 1077
CSA 22.2 No. 235
VDE (IEC 60898)
1960V AC
1960V AC
Certifications
Dielectric Strength
1960V AC
Shock
100...500 Hz for 1 Hour
Wire Size
#14...1/0 AWG
UL 489 specifications
UL 489 specifications
6000 operations
10 kA @ 240V AC
10 kA @ 120/240V AC
IEC 60898
10 kA @ 415V AC
UL/CSA 10 kA U2
32...140 F (0+60 C)
32...140 F (0+60 C)
23...104 F (-5+40 C)
Page 7-6
Page 7-11
Page 7-40
Interrupt Rating
Operating Temperature (noncondensing)
Product Selection
3
4
5
6
Vibration
Electromechanical Life
7
8
9
10
11
12
13
7-3
01_1492_Gen_Info.qxd
4/25/2008
1:14 PM
Page 7-4
Bulletin 1492
Product Selection
Bulletin 1492-FB Fuse Holders
1
2
3
4
5
UL1077, CSA C22.2 No. 235 In North America, miniature circuit breakers are recognized as supplementary protectors and are intended for
use as overcurrent protection within an appliance or other electrical equipment where branch circuit protection is already provided or not
required. Internationally, these products are rated to IEC standards as miniature circuit breakers or circuit breakers for equipment.
UL508, CSA 22.2 No.14 In North America, some miniature circuit breakers, meeting specific requirements, may be used as Manual Motor
Controllers for direct control of motors connected across-the-line equipment where branch circuit protection is already provided or not
required. Internationally, these products are rated to IEC standards as miniature circuit breakers and applied for motor controller applications
within those standards.
UL489, CSA 22.2 No. 5.1 In North America, some miniature circuit breakers, meeting specific requirements, may be used as Branch
Circuit Protection devices for the protection of electric wiring as well as load protection.
Type
UL
CSA
Certifications
EN/IEC
CE Marked
1492-SP
1492-MC
1077
1077
489
1489
489
IEC 60934
IEC 60934
IEC 60898
IEC 60947-2
60947-2
Yes
Yes
Yes
1,2,3
1, 2, 3
1, 2, 3
250 V
480Y/277 V
480Y/277 V
120/240V AC
240V AC
480Y/277 V
65 V
65 V
1p 48V
2p (series) 125V
1-pole: 48V DC
2-pole: 96V DC
0.215A
0.225A
0.563A
15100 A
0.540 A
G 612
G 610
B 35
C 510
D 1020
UL 489 Standard
(CSA 22.2 No. 5.1)
B 35
C 510
D 1020
Energy Limiting
No
No
Yes
No
Yes
No. of Pole/foot
24
24
17
Varies
17
DIN Rail
DIN Rail
DIN Rail
Volts DC
Current Range
Trip Characteristics
(In)
Mounting Method
10
1492-GS
1077
Volts AC
1492-GH
Yes
No. of Poles
y Relay/contactor coils
y PLCs
y Medical Equipment
y PLC I/O Points
Yes
Yes
Yes
Varies
Yes
Auxiliary Contacts
No
Yes
Yes
No
Yes
Shunt Trip
No
No
Yes
No
Yes
Undervoltage Trip
No
No
Yes
No
Yes
11
12
13
Visit our website: www.ab.com/catalogs
7-4
01_1492_Gen_Info.qxd
4/25/2008
1:14 PM
Page 7-5
Bulletin 1492
!
1
2
3
4
5
6
7
8
9
10
11
12
13
7-5
02_1492MC.qxd
4/25/2008
1:16 PM
Page 7-6
Bulletin 1492-MC
Circuit Breaker
Overview/Description
Bulletin 1492-MC Circuit Breakers
Industrial Circuit Breakers for North American Applications
Table of Contents
Specifications.............. 7-12
AC DIN Rail
Mounting ....................... 7-11
Product Selection ...... 7-12
Approximate
Dimensions................... 7-13
Features
y Designed, manufactured and listed to UL 489 (CSA C22.2, No. 5.1)
y Thermal-magnetic protection
y All Ratings (10100 A) are HACR rated
y 10 kAIC (10100 A)
y Finger-safe design (front) (1/2 in. wide)
y DIN Rail mounting (120/240 & 240V AC)
y Three-position handle (ON, Tripped (Middle), OFF)
y (Line and load) wire connections
2
3
4
5
6
7
Standards Compliance
for Bul. 1492-MC
y UL 489
y CSA C22.2 No. 5.1
y HACR (10-100 A)
y SWD (15 and 20 A) for
Switching Duty for
flourescent lighting
applications
y UL 943
y CSA C22.2 No. 144
y UL 1053
y CSA C22.2 No. 144
The 1492-MC Thermal Magnetic Circuit Breakers are generalpurpose devices suitable for the majority of industrial, inverse time
circuit breaker applications.
8
9
10
11
12
Certifications
UL Listed
CSA Certified
AC Voltage
120/240
240
DC Voltage 9
24, 48, 62.5
3,000
10,000
120/240
240
120
120/240
Cat. No.
1492-MCAA1xx
1492-MCAA2xx
1492-MCAA2Hxx
1492-MCAA3xx
1492-MCBA1xx
1492-MCBA2xx
1492-MCBA2Hxx
1492-MCBA3xx
1492-MCEA1xx
120/240
10,000
1492-MCEA2xx
1492-MCGA1xx
1492-MCGA2xx
Circuit Frequency
The 1492-MC circuit breakers may be applied to frequencies from
DC up to 60 Hz without derating. For applications above 60400
Hz, contact Rockwell Automation with specific application
information for the derating of the circuit breakers.
13
Visit our website: www.ab.com/catalogs
7-6
DC Rating 9
3,000
120
Circuit Voltage
AC Rating
02_1492MC.qxd
4/25/2008
1:16 PM
Page 7-7
Bulletin 1492-MC
Circuit Breaker
Description, Continued
Continuous Current Rating
Branch Circuits:
Standard current ratings are, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55,
60, 70, 80, 90, and 100 A.
Application Considerations
References: NEC 450 and UL 508A. Also see CEC and appropriate
Canadian Standards.
1
Bulletin 1492-MC circuit breakers are not horsepower rated because
they are able to safely interrupt currents far in excess of the locked
rotor value for a selected motor. This ability is recognized in the
codes and standards and is also established by the UL and CSA
tests described in UL 489 and CSA C22.2 No. 5.1 standards.
4
5
6
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-7
02_1492MC.qxd
4/25/2008
1:16 PM
Page 7-8
Bulletin 1492-MC
Circuit Breaker
Description, Continued
Time Current Curve 1-Pole Circuit Breaker
!
Time Current Curve
1492-MCEA1NN
1492-MCGA1NN
60,000
70,000
80,000
90,000
100,000
50,000
40,000
30,000
20,000
6000
7000
8000
9000
10,000
5000
2000
600
700
800
900
1000
500
300
200
60
70
80
90
100
50
4000
1492-MCAA1NN
1492-MCBA1NN
3000
10,000
40 C Ambient
1 HOUR
5,000
Open Air
3,000
3,000
2,000
2,000
1,000
1,000
500
500
300
300
200
200
100
100
(50-70 Amp)
50
(10-40 Amp)
Maximum Single-Pole
Trip Times at 25 C
50
30
30
20
20
Minimum
Maximum
10
7
TIME IN SECONDS
10
.5
.5
.3
.3
.2
.2
.1
.1
10
.05
.05
.03
.03
Maximum Interrupting
.01
7-8
60,000
70,000
80,000
90,000
100,000
50,000
40,000
30,000
20,000
6000
7000
8000
9000
10,000
5000
4000
.001
3000
.001
2000
.002
600
700
800
900
1000
.003
.002
500
.003
400
.005
300
.005
50
13
.01
200
12
.02
60
70
80
90
100
11
Time
.02
TIME IN SECONDS
1 MINUTE
1 MINUTE
1 HOUR
5,000
2 HOURS
2 HOURS
10,000
02_1492MC.qxd
4/25/2008
1:16 PM
Page 7-9
Bulletin 1492-MC
Circuit Breaker
Description, Continued
Time Current Curve 2-Pole Circuit Breakers
!
Time Current Curve
1492-MCAA2HNN 1492-MCEA2NN
1492-MCBA2HNN 1492-MCGA2NN
1
60,000
70,000
80,000
90,000
100,000
50,000
40,000
30,000
20,000
6000
7000
8000
9000
10,000
5000
4000
2000
500
400
300
200
60
70
80
90
100
50
3000
1492-MCAA2NN
1492-MCBA2NN
2 HOURS
2 HOURS
40C Ambient
4 ft 60/75C Wire per Terminal
5,000
Open Air
1 HOUR
5,000
1 HOUR
10,000
10,000
3,000
3,000
2,000
2,000
1,000
1,000
500
500
300
300
200
200
100
100
50
50
30
30
20
20
Minimum
4
5
6
Maximum
10
10
.5
.5
.3
.3
.2
.2
.1
.1
7
8
TIME IN SECONDS
9
10
.05
.05
.03
.03
Maximum Interrupting
Time
.02
.02
.01
.01
11
12
13
60,000
70,000
80,000
90,000
100,000
50,000
40,000
30,000
20,000
6000
7000
8000
9000
10,000
5000
4000
3000
.001
2000
.001
600
700
800
900
1000
.002
500
.002
400
.003
300
.003
200
.005
60
70
80
90
100
.005
50
TIME IN SECONDS
1 MINUTE
1 MINUTE
7-9
02_1492MC.qxd
4/25/2008
1:16 PM
Page 7-10
Bulletin 1492-MC
Circuit Breaker
Description, Continued
Time Current Curve 3-Pole Circuit Breakers
50,000
40,000
30,000
20,000
6000
7000
8000
9000
10,000
5000
4000
3000
2000
500
400
300
200
70
80
90
100
50
60
10,000
40C Ambient
4 ft 60/75C Wire per Terminal
1 HOUR
3,000
2,000
1,000
1,000
500
1 MINUTE
300
300
200
200
100
100
50
50
30
30
20
20
Minimum
Maximum
10
8
9
10
.5
.5
.3
.3
.2
.2
.1
.1
.05
10
.05
.03
.03
11
.02
.02
.01
.01
.005
.005
.003
.003
.002
.002
.001
.001
60,000
70,000
80,000
90,000
100,000
50,000
40,000
30,000
20,000
6000
7000
8000
9000
10,000
5000
4000
3000
2000
600
700
800
900
1000
500
400
300
200
60
70
80
90
100
50
12
CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING
13
Visit our website: www.ab.com/catalogs
7-10
TIME IN SECONDS
TIME IN SECONDS
1 MINUTE
3,000
2,000
500
5,000
Open Air
1 HOUR
5,000
2 HOURS
2 HOURS
10,000
02_1492MC.qxd
4/25/2008
1:16 PM
Page 7-11
Bulletin 1492-MC
Circuit Breaker
Catalog Number Explanation/Product Selection
1492-MC Cat. No. Explanation
Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all
combinations will produce a valid catalog number.
1492-MC
15
Body Style
Poles
Code
Description
Code
!
1
d
Current Rating
Size
Description
Code
Description
Code
Description
1 Pole
10
10 A
50
50 A
2 Poles
15
15 A
55
55 A
2H
20
20 A
60
60 A
GFCI (5 mA)
3 Poles
25
25 A
70
70 A
30
30 A
80
80 A
35
35 A
90
90 A
Interrupt Rating
40
40 A
A0
100 A
45
45 A
Code
Description
10 kA AIC
2
3
4
Cat. No.
120/240V AC
240V AC
Continuous Ampere
Rating @ 40C (104F)
Width [in.]
Width [in.]
2 poles
3 poles
10
1/2
1492-MCAA110 1492-MCAA210
1 pole
2 poles
15
1/2
1492-MCAA115 1492-MCAA215
1/2
20
1/2
1492-MCAA120 1492-MCAA220
1/2
1492-MCAA2H20 1492-MCAA320
25
1/2
1492-MCAA125 1492-MCAA225
1/2
1492-MCAA2H25 1492-MCAA325
30
1/2
1492-MCAA130 1492-MCAA230
1/2
1492-MCAA2H30 1492-MCAA330
35
1/2
1492-MCAA135 1492-MCAA235
1492-MCBA2H35 1492-MCBA335
40
1/2
1492-MCAA140 1492-MCAA240
1492-MCBA2H40 1492-MCBA340
45
1/2
1492-MCAA145 1492-MCAA245
1492-MCBA2H45 1492-MCBA345
50
1/2
1492-MCAA150 1492-MCAA250
1492-MCBA2H50 1492-MCBA350
55
1/2
1492-MCAA155 1492-MCAA255
1492-MCBA2H55 1492-MCBA355
60
1/2
1492-MCAA160 1492-MCAA260
1492-MCBA2H60 1492-MCBA360
70
1492-MCBA170 1492-MCBA270
1492-MCBA2H70 1492-MCBA370
80
1492-MCBA180 1492-MCBA280
1492-MCBA2H80 1492-MCBA380
90
1492-MCBA190 1492-MCBA290
1492-MCBA2H90 1492-MCBA390
100
1492-MCBA1A0 1492-MCBA2A0
1492-MCBA2HA0 1492-MCBA3A0
1492-MCAA2H15 1492-MCAA315
6
7
8
9
10
11
Auxiliary Devices
Device description
Locking Attachment for Circuit Breaker
1 pole
1492-MCAAxxx
1492-AMCAL1
1492-MCBAxxx
1492-AMCBL1
2 and 3 poles
1492-AMCALM
Finger protection cover for 1 in. wide 1492-MCBxxx, package of 10 (one required
for line and one required for load for each pole) (not for GFCI / GFEP)
1492-AMCBFP
DIN Rail adapter, per pole, DIN Rail mounting for GFCI, GFEP
1492-AMCDIN1
Panel Mounting Clips for GFCI and GFEP, two required per device
1492-AMCP1
13
12
7-11
02_1492MC.qxd
4/25/2008
1:17 PM
Page 7-12
Bulletin 1492-MC
Circuit Breaker
Product Selection, Continued/Specifications
1492-MC Product Selection
Cat. No.
Cat. No.
120V AC
120/240V AC
1
2
1492-MCGA115 1492-MCGA215
20
1492-MCGA120 1492-MCGA220
25
1492-MCGA125 1492-MCGA225
30
1492-MCGA130 1492-MCGA230
40
1492-MCGA140 1492-MCGA240
50
1492-MCGA250
15
1492-MCEA115 1492-MCEA215
20
1492-MCEA120 1492-MCEA220
25
1492-MCEA125 1492-MCEA225
30
1492-MCEA130 1492-MCEA230
40
1492-MCEA140 1492-MCEA240
50
1492-MCEA250
4
5
Standards Compliance
Certifications
Rated Voltage
10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80 90, 100 Amp
Degree of protection
Open Device 1/2 in. wide circuit breakers are finger safe from front per IEC. Terminal
Covers available for 1 in. wide circuit breaker at 120/240 and 240V AC.
Mounting
Operating Temperature
-40C+80C (-40...176F)
Wire Size
Terminal Torque
6
7
Terminals
Cat. No.
Continuous Current
Rating
Wire Type
8
1492-MCAAxxx
1060 A
Terminal Torque
1410
20 lbin.
(2.3 Nm)
25 lbin.
(2.8 Nm)
64
27 lbin.
(3.0 Nm)
1410
20 lbin.
(2.3 Nm)
84
32 lbin.
(3.6 Nm)
41/0
50 lbin.
(5.6 Nm)
1410
3560 A
10
7/16 in.
20 lbin
(2.3 Nm)
9/16 in.
Line
25 lbin
(2.8 Nm)
1492-MCBAxxx
70100 A
Copper (Cu)
11
1492-MCEAxxx
12
13
1550 A
Load
1492-MCGAxxx
64
27 lbin
(3.0 Nm)
7-12
02_1492MC.qxd
4/25/2008
1:17 PM
Page 7-13
Bulletin 1492-MC
Circuit Breaker
Approximate Dimensions
1492-MC Approximate Dimensions
Note: Dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes.
Catalog Type
No. of Poles
Width [in.]
1492-MCAA1xx
1060
0.490
1492-MCAA2xx
1060
0.980
1492-MCAA2Hxx
1530
0.980
1492-MCAA3xx
1530
1.470
1492-MCBA1xx
70...100
1.000
1492-MCBA2xx
70...100
2.000
1492-MCBA2Hxx
35...100
2.000
1492-MCBA3xx
35...100
3.000
1492-MCEA1xx
15...50
0.990
1492-MCEA2xx
15...50
1.980
1492-MCGA1xx
15...50
0.990
1492-MCGA2xx
15...50
1.980
1492-MCAAnxx
0.865
(21.97)
2.513
(63.83)
1.780
(45.21)
On
0.360
(9.14)
2.250
(57.15)
1.272
(32.31)
1.378
(35.00)
DIN Rail
Mounting
Location
18?
24?
3.938
(100.03)
0.640
(16.26)
Radius
Off
Reset 0.844
(21.44)
0? Trip
0.495
(12.45)
0.813
(20.65)
0.990
(25.15)
1.250
(31.75)
2.250
(57.15)
2.500
(63.50)2.750
(69.85)
Width
0.750
(19.05)
Front View
18?
1
2
3
1492-MCEA1xx
1492-MCGA1xx
1.480
(37.60)
0.844
(21.44)
0.938
(23.83)
18 ?
18 ?
24 ?
On
Off
Reset
2.850
(72.39)
2.249
(57.12)
0?
Trip
4
0.219
(5.56)
5
0.454 0.562
(11.53) (14.27)
Side View
1.240
(31.50)
1.500
0.156 (38.10)
(3.96)
3.375
(85.73)
0.156
(3.96)
3.812
(96.82)
0.188
(4.78)
7
8
2.250
(57.15)
0.096
(2.44)
1.470
(37.34)
0.094
(2.39)
Radius
0.578
(14.68)
3.125
Terminal (79.38) 1.480
#14-4
(37.60)
1.404
(35.66)
2.500
(63.50)
2.438
(61.93)
2.344
(59.54)
2.713
(68.91)
Ground Neutral
Wire Length
24.000 inches
(609.60)
9
10
11
12
13
7-13
02_1492MC.qxd
4/25/2008
1:17 PM
Page 7-14
Bulletin 1492-MC
Circuit Breaker
Approximate Dimensions, Continued
Note: Dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes.
1492-MCEA2xx
1492-MCGA2xx
0.219
(5.56)
0.562
(14.27)
2.890
(73.41)
Front View
1.980
(50.29)
0.495
(12.57)
0.813
(20.65)
2.250
(57.15)
0.990
(25.15)
1.250
(31.75)
0.938
(23.83)
2.249
(57.12)
2.249
(57.12)
25A thru
50A style
Radius
0.578
(14.68)
24 ?
0.454
(11.53)
Side View
1.240
(31.50)
1.500
(38.10)
3.375
(85.73)
3.812
(96.82)
0?
Trip
18
18 ?
On
Reset
Off
0.188
(4.78)
0.096
(2.44)
2.713
(68.91)
Bottom View
2.500
(63.50)
1.855 1.739
(47.12) (44.17)
Ground Neutral
Wire Length
24.000 inches
(609.60)
1.960
(49.53)
2.344
(59.54)
0.993
(25.22)
2.438
(61.93)
1492-MCBAxxx
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
7-14
03_1489.qxd
4/25/2008
1:18 PM
Page 7-15
Bulletin 1489
Circuit Breaker
Overview/Description
Bulletin 1489 Circuit Breakers
Table of Contents
Specifications.............. 7-24
Description ................... this page
Product Selection ...... 7-21
Approximate
Dimensions................... 7-25
UL 489
CSA C22.2 No. 5.1
EN/IEC 60947-2
Certifications
UL Listed
CSA Certified
CE Marked
VDE Certified
3
4
Features
y Designed manufactured and listed to UL 489 (CSA 22.2 No. 5.1)
y Thermal-magnetic protection
y All ratings are HACR rated
y 10 kA Interrupting rating
y Fingersafe design (front)
y DIN Rail mounting
y Line and load wire connections
y Optional ring terminal connections (convertible)
10
EN/IEC Regions
Circuit Frequency
y Circuit Voltage
y Circuit Frequency
Region
Circuit Voltage
Description
Standards Compliance
Max. Voltage
415V AC
0.5...40
48V DC
0.5...40
240V AC
0.5...40
480Y/277V AC
0.5...25
1-pole 48V DC
0.5...40
2-pole 96V DC
0.5...40
11
12
13
7-15
03_1489.qxd
4/25/2008
1:18 PM
Page 7-16
Bulletin 1489
Circuit Breaker
Description, Continued
Continuous Current Rating
Standard current ratings are: 0.5, 1, 1.5, 2, 3, 4, 5, 6, 7, 8, 10, 15,
16, 20, 25, 30, 32, 35, and 40 A.
!
1
2
3
4
5
The characteristic trip curves are shown on page 7-19. The trip
bands shown for each breaker represent current tripping limits for a
circuit breaker and are within the limits established by UL. For a
specific current at 40 C (104 F), a circuit breaker will open ("clear
the circuit") automatically at some total time that will be within the
"Minimum" and "Maximum" time shown on the curves. For
example, page 7-18 shows that a one-pole, 15 A, Bulletin 1489
circuit breaker trips in not less than 10 s and not more than 120 s
on a 30 A current. Because the UL standard defines this time
spread, users should not specify exact tripping time. The lower
current portion of the curves (upper left) depict the time to trip due
to thermal action and reflect overload protection of the wire and
connect load. The higher current portion of the curves (lower right)
depicts the trip due to magnetic action of the circuit breaker and
reflects protection due to short circuit level currents.
Application Considerations
6
7
8
9
10
The Bulletin 1489 circuit breakers are non 100 percent rated as
defined by UL 489, para 7.1.4.2. As such, the circuit breaker's
rating should be loaded to no more than 80% if used with
continuous loads.
Line and load may be reversed. The Bulletin 1489 circuit breaker
may be bottom fed.
Branch Circuits:
11
12
13
7-16
03_1489.qxd
4/25/2008
1:19 PM
Page 7-17
Bulletin 1489
Circuit Breaker
Description, Continued
Both of these factors are proportional to the square of the current.
Thermal energy is proportional to the square of the RMS value and
magnetic forces are proportional to the square of the peak value.
The most effective way to provide protection is to substantially limit
let-through-energy. This provides the following advantages
Determining Ratings
y Far less wear on the miniature circuit breaker itself. This means
more safe interruptions.
Use the following table and graph to determine the current rating for
the breaker if the ambient is significantly different than 40 C.
15 C
20 C
25 C
30 C
50 C
55 C
0.5
0.6
0.5
0.5
0.5
0.5
0.5
1.0
1.1
1.1
1.1
1.0
1.0
0.9
Frequency: 50/60 Hz
1.5
1.7
1.6
1.6
1.6
1.4
1.4
2.0
2.2
2.2
2.1
2.1
1.9
1.9
3.0
3.3
3.2
3.2
3.1
2.9
2.8
4.0
4.4
4.3
4.2
4.2
3.8
3.8
Vrms
240 V
(D40)
480Y/277V(D25)
5.0
5.5
5.4
5.3
5.2
4.8
4.7
Symmetrical (kA)
2.6
1.625
6.0
6.6
6.5
6.4
6.2
5.8
5.6
I peak (kA)
2.9
2.0
7.0
7.7
7.6
7.4
7.3
6.7
6.6
8.0
8.8
8.6
8.5
8.3
7.7
7.5
10.0
11.0
10.8
10.6
10.4
9.6
9.4
13.0
14.3
14.0
13.8
13.5
12.5
12.2
15.0
16.5
16.2
15.9
15.6
14.4
14.1
16.0
17.6
17.3
17.0
16.6
15.4
15.0
20.0
22.0
21.6
21.2
20.8
19.2
18.8
25.0
27.5
27.0
26.5
26.0
24.0
23.5
30.0
33.0
32.4
31.8
31.2
28.8
28.2
32.0
35.2
34.6
33.9
33.3
30.7
30.1
40.0
44.0
43.2
42.4
41.6
38.4
37.6
I2t (kA2s)
Intermediate
Current
High Interrupt
Current
18.0
12.0
Symmetrical (kA)
5.0
5.0
I peak (kA)
4.2
4.6
I2t (kA2s)
24.0
38.0
Symmetrical (kA)
10.0
10.0
I peak (kA)
6.2
6.2
I2t (kA2s)
43.0
60.0
1
2
Device Marked
Current Rating [A] @
40 C
Threshold Current
3
4
5
6
7
Note: The table shows the corrected values of the rated current dependent
on the ambient temperature.
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-17
03_1489.qxd
4/25/2008
1:19 PM
Page 7-18
Bulletin 1489
Circuit Breaker
Description, Continued
Bus Bars
1.40
1
Load Factor K T [I/In ]
Lock-out Attachment
1.30
1.20
1.10
Shunt Trip
1.00
3
0.90
Auxiliary Contacts
-20
-10
10
20
30
40
50
Terminals
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
7-18
03_1489.qxd
4/25/2008
1:19 PM
Page 7-19
Bulletin 1489
Circuit Breaker
Description, Continued
Type C and D
Ambient Temperature 40 C
7200
3600
tripping characteristic
acc. to UL 489
1
1200
600
300
120
3
4
60
instantaneous tripping
acc. to IEC 60898-1
30
10
t [sec]
5
6
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
10
0.002
0.001
0.0005
1
7 8 9 10
15
20
30
40
11
50
I / IN
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-19
03_1489.qxd
4/25/2008
1:19 PM
Page 7-20
Bulletin 1489
Circuit Breaker
Catalog Number Explanation
Bulletin 1489 Cat. No. Explanation
Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all
combinations will produce a valid catalog number.
!
1
2
3
005
Body Style
Factory Modifications
Code
Description
Code
Current [A]
Code
Description
005
0.5
blank
Standard Terminal
Ring Terminal
010
015
1.5
Poles
020
Code
Description
030
1-Pole
040
2-Pole
050
3-Pole
060
070
4
5
1489 - A
Trip Curve
080
100
10
Code
Trip Curve
130
13
Trip Curve C
150
15
Trip Curve D
160
16
200
20
250
25
300
30
320
32
350
35
400
40
6
7
8
9
10
11
12
13
7-20
03_1489.qxd
4/25/2008
1:19 PM
Page 7-21
Bulletin 1489
Circuit Breaker
Product Selection
Bulletin 1489 1-Pole Miniature Circuit Breakers
No. of Poles
Trip Curve
415V AC
48V DC
Standard Wire
Configuration Cat. No.
Ring Terminal
Configuration Cat. No.
0.5
1489-A1C005
1489-A1C005R
1489-A1C010
1489-A1C010R
1.5
1489-A1C015
1489-A1C015R
1489-A1C020
1489-A1C020R
1489-A1C030
1489-A1C030R
1489-A1C040
1489-A1C040R
1489-A1C050
1489-A1C050R
1489-A1C060
1489-A1C060R
1489-A1C070
1489-A1C070R
1489-A1C080
1489-A1C080R
10
1489-A1C100
1489-A1C100R
13
1489-A1C130
1489-A1C130R
15
1489-A1C150
1489-A1C150R
16
1489-A1C160
1489-A1C160R
20
1489-A1C200
1489-A1C200R
25
1489-A1C250
1489-A1C250R
30
1489-A1C300
1489-A1C300R
32
1489-A1C320
1489-A1C320R
35
1489-A1C350
1489-A1C350R
40
1489-A1C400
1489-A1C400R
0.5
1489-A1D005
1489-A1D005R
1489-A1D010
1489-A1D010R
1.5
1489-A1D015
1489-A1D015R
1489-A1D020
1489-A1D020R
1489-A1D030
1489-A1D030R
1489-A1D040
1489-A1D040R
1489-A1D050
1489-A1D050R
1489-A1D060
1489-A1D060R
1489-A1D070
1489-A1D070R
1489-A1D080
1489-A1D080R
10
1489-A1D100
1489-A1D100R
13
1489-A1D130
1489-A1D130R
15
1489-A1D150
1489-A1D150R
16
1489-A1D160
1489-A1D160R
20
1489-A1D200
1489-A1D200R
25
1489-A1D250
1489-A1D250R
30
1489-A1D300
1489-A1D300R
32
1489-A1D320
1489-A1D320R
35
1489-A1D350
1489-A1D350R
40
1489-A1D400
1489-A1D400R
!
1
2
3
4
5
6
7
8
9
10
11
12
13
7-21
03_1489.qxd
4/25/2008
1:19 PM
Page 7-22
Bulletin 1489
Circuit Breaker
Product Selection, Continued
Bulletin 1489 2-Pole Miniature Circuit Breakers
No. of Poles
EN/IEC Maximum
Voltage
Trip Curve
1
2
480Y/277V AC 96V DC
C
3
4
240V AC 96V DC
2
415V AC 48V DC
5
6
480Y/277V AC 96V DC
8
240V AC 96V DC
Rated Current
Ring Terminal
Configuration Cat. No.
0.5
1489-A2C005R
1489-A2C005R
1489-A2C010
1489-A2C010R
1.5
1489-A2C015
1489-A2C015R
1489-A2C020
1489-A2C020R
1489-A2C030
1489-A2C030R
1489-A2C040
1489-A2C040R
1489-A2C050
1489-A2C050R
1489-A2C060
1489-A2C060R
1489-A2C070
1489-A2C070R
1489-A2C080
1489-A2C080R
10
1489-A2C100
1489-A2C100R
13
1489-A2C130
1489-A2C130R
15
1489-A2C150
1489-A2C150R
16
1489-A2C160
1489-A2C160R
20
1489-A2C200
1489-A2C200R
25
1489-A2C250
1489-A2C250R
30
1489-A2C300
1489-A2C300R
32
1489-A2C320
1489-A2C320R
35
1489-A2C350
1489-A2C350R
40
1489-A2C400
1489-A2C400R
0.5
1489-A2D005
1489-A2D005R
1489-A2D010
1489-A2D010R
1.5
1489-A2D015
1489-A2D015R
1489-A2D020
1489-A2D020R
1489-A2D030
1489-A2D030R
1489-A2D040
1489-A2D040R
1489-A2D050
1489-A2D050R
1489-A2D060
1489-A2D060R
1489-A2D070
1489-A2D070R
1489-A2D080
1489-A2D080R
10
1489-A2D100
1489-A2D100R
13
1489-A2D130
1489-A2D130R
15
1489-A2D150
1489-A2D150R
16
1489-A2D160
1489-A2D160R
20
1489-A2D200
1489-A2D200R
25
1489-A2D250
1489-A2D250R
30
1489-A2D300
1489-A2D300R
32
1489-A2D320
1489-A2D320R
35
1489-A2D350
1489-A2D350R
40
1489-A2D400
1489-A2D400R
10
11
12
13
Visit our website: www.ab.com/catalogs
7-22
03_1489.qxd
4/25/2008
1:19 PM
Page 7-23
Bulletin 1489
Circuit Breaker
Product Selection, Continued
Bulletin 1489 3-Pole Miniature Circuit Breakers
No. of Poles
EN/IEC Maximum
Voltage
Trip Curve
480Y/277V AC
C
240V AC
3
415V AC 48V DC
480Y/277V AC
D
240V AC
Ring Terminal
Configurations Cat. No.
0.5
1489-A3C005
1489-A3C005R
1489-A3C010
1489-A3C010R
1.5
1489-A3C015
1489-A3C015R
1489-A3C020
1489-A3C020R
1489-A3C030
1489-A3C030R
1489-A3C040
1489-A3C040R
1489-A3C050
1489-A3C050R
1489-A3C060
1489-A3C060R
1489-A3C070
1489-A3C070R
1489-A3C080
1489-A3C080R
10
1489-A3C100
1489-A3C100R
13
1489-A3C130
1489-A3C130R
15
1489-A3C150
1489-A3C150R
16
1489-A3C160
1489-A3C160R
20
1489-A3C200
1489-A3C200R
25
1489-A3C250
1489-A3C250R
30
1489-A3C300
1489-A3C300R
32
1489-A3C320
1489-A3C320R
35
1489-A3C350
1489-A3C350R
40
1489-A3C400
1489-A3C400R
0.5
1489-A3D005
1489-A3D005R
1489-A3D010
1489-A3D010R
1.5
1489-A3D015
1489-A3D015R
1489-A3D020
1489-A3D020R
1489-A3D030
1489-A3D030R
1489-A3D040
1489-A3D040R
1489-A3D050
1489-A3D050R
1489-A3D060
1489-A3D060R
1489-A3D070
1489-A3D070R
1489-A3D080
1489-A3D080R
10
1489-A3D100
1489-A3D100R
13
1489-A3D130
1489-A3D130R
15
1489-A3D150
1489-A3D150R
16
1489-A3D160
1489-A3D160R
20
1489-A3D200
1489-A3D200R
25
1489-A3D250
1489-A3D250R
30
1489-A3D300
1489-A3D300R
32
1489-A3D320
1489-A3D320R
35
1489-A3D350
1489-A3D350R
40
1489-A3D400
1489-A3D400R
!
1
2
3
4
5
6
7
8
9
10
11
12
13
7-23
03_1489.qxd
4/25/2008
1:19 PM
Page 7-24
Bulletin 1489
Circuit Breaker
Accessories/Specifications
Miniature Circuit Breaker Accessories
!
1
2
Description
CSA/UL Certifications
IEC 60947-2
Compliance
CE
Connection
Cat. No.
Lockout Attachment
Yes
Yes
Yes
1489-AALOA
Yes
Yes
Yes
3 A, 250V AC (AC13)
0.5 A, 110V DC
2 A, 240V AC
0.5 A, 110V DC
Cable
1489-AAHH3
Auxillary/Signal Contact,
each are Form C, 1 N.O.
& 1 N.C.
Yes
Yes
Yes
3 A, 250V AC (AC13)
0.5 A, 110V DC
2 A, 240V AC
0.5 A, 110V DC
Cable
1489-AAHS3
Yes
Yes
Yes
110...415V AC
110230V DC
110...415V AC
110230V DC
Cable
1489-AASTA1
Yes
12...110V AC
1260V DC
12...110V AC
1260V DC
Cable
1489-AASTA2
Yes
Yes
9 Use of auxilliary or signal contact limits the circuit breaker to a maximum voltage of 240V AC for UL/CSA applications.
No. of Phases
Pkg Qty.
Cat. No.
1489-AACL106
3
4
No. of Poles
12
Bus Bar7
12
1489-AACL112
18
18
1489-AACL118
1489-AACL206
1489-AACL212
18
1489-AACL218
1489-AACL306
1489-AACL312
1489-AACL318
12
12
10
18
Description
No. of Poles
Pkg Qty.
Wire Range
Cat. No.
Terminal Lug
10
#14 2 AWG
2.5 35 mm2
1489-AACLT35
10
1489-AACLPS
Specifications
7
8
Number of Poles
1, 2, and 3
Standards
UL 489
CSA C22.2 No. 5.1
EN/IEC 60947-2
Certifications
Yes
Yes (0.5...20 A)
Calibration Temperature
UL/CSA: 40 C EN/IEC: 30 C
Degree of Protection
9
10
11
12
13
Dielectric Strength
1960V AC
Shock
Vibration
Trip Curves
-40...+85 C (-40...+185 F)
Wire Size
Terminal Torque
0.5 in.
7-24
03_1489.qxd
4/25/2008
1:19 PM
Page 7-25
Bulletin 1489
Circuit Breaker
Approximate Dimensions
Bulletin 1489 Circuit Breaker Approximate Dimensions
Note: All unites are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes.
!
1
2
3
4
5
Catalog Number
Without R Suffix
With R Suffix
Access Hole
Dia. in Housing
(mm)
Terminal
Screw Head
Diam (mm)
Cable
8.2
10
Non-Removable
Ring Lug
8.2
Removable
Line/Load
Terminal
Style
Comment:
Terminal Screw
Type
#2
PoziDrive
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-25
03_1489.qxd
4/25/2008
1:20 PM
Page 7-26
Bulletin 1489
Circuit Breaker
Approximate Dimensions, Continued
Note: All unites are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes.
!
1
2
3
4
5
1489-AAHH3 & 1489-AAHS3
6
7
8
9
10
1489-AAST1, 1489-AAST2
11
12
13
1489-AACL106
7-26
03_1489.qxd
4/25/2008
1:20 PM
Page 7-27
Bulletin 1489
Circuit Breaker
Approximate Dimensions, Continued
Note: All unites are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes.
!
1
2
1489-AACL112
3
4
1489-AACL118
5
6
7
8
1489-AACL206
9
10
11
1489-AACL212
12
13
1489-AACL218
7-27
03_1489.qxd
4/25/2008
1:20 PM
Page 7-28
Bulletin 1489
Circuit Breaker
Approximate Dimensions, Continued
Note: All unites are in millimeters unless indicated. Dimensions are not intended for manufacturing purposes.
!
1
2
3
1489-AACL306
4
5
1489-AACL312
6
7
8
1489-AACL318
6
1 3 ,5
14mm
.56 In
71,6
E300325
UL489
10
16,2
31,3
11
1489-AACLT35
17,6
17,6
7
3,55
12
24
16
13
BLACK
PRINTING
1489-AACLPS
7-28
04_1492FB.qxd
4/25/2008
1:21 PM
Page 7-29
Bulletin 1492-FB
Fuse Holders
Overview/Product Selection
Bulletin 1492-FB DIN Rail Mounting Fuse Holders
Table of Contents
Standards Compliance
UL 512
CSA 22.2 No. 39
EN/IEC 60947-3
EN/IEC 60269-2-1
Certifications
UL Listed
UR Recognized Component
CSA Certified
CE Marked
Bulletin 1492-FB fuse holders provide a safe and convenient means for installation of class CC, J, and midget fuses. The class CC fuse
holder is designed to reject a midget fuse or international 10 x 38 mm fuse. The class J fuse holder will reject all fuses other than a class J
fuse.
The class CC and J holders are UL Listed and CSA Certified for branch circuit protection. Class CC and J fuses are excellent for wire
protection, small motor loads, and group protection of small motor loads. The midget holders are UL Recognized and CSA Certified when
supplementary (1-1/2 in. x 13/32 in.) fuses are applied. The midget fuse holder is also CE Marked for 10 x 38 mm IEC midget fuses.
4
5
The 1492-FB fuse holder family is designed for use in many OEM applications, such as power supplies, equipment protection, primary and
secondary control transformers, solenoids, lighting and heater loads, and drives.
Product Selection
For Class CC Fuse
60 A
30 A
Cat. No.
Cat. No.
Cat. No.
Cat. No.
1492-FB1C30
1492-FB1J30
1492-FB1J60
1492-FB1M30
1492-FB1C30-L
1492-FB1J30-L
1492-FB1J60-L
1492-FB1M30-L
1492-FB1C30-D1
1492-FB1M30-D1
1492-FB2C30
1492-FB2J30
1492-FB2J60
1492-FB2M30
1492-FB2C30-L
1492-FB2J30-L
1492-FB2J60-L
1492-FB2M30-L
30 A
Description
One-Pole
30 A9
3
1492-FB3C30
1492-FB3J30
1492-FB3J60
1492-FB3M30
1492-FB3C30-L
1492-FB3J30-L
1492-FB3J60-L
1492-FB3M30-L
9 All major fuse brands and current ranges have been evaluated for this fuse holder. Due to the heat they generate, the following fuses must be derated:
10
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-29
04_1492FB.qxd
4/25/2008
1:21 PM
Page 7-30
Bulletin 1492-FB
Fuse Holders
Specifications/Accessories/Approximate Dimensions
Specifications
30 A
Certifications
60 A
UR, CSA, CE
600V AC/DC
200 kA
50 kA
Yes
No
Operating Temperature
4+130 F (20+55 C)
Contact Material
30 A
UL, CSA, CE
30 A
With Indicator
Silver, Ag
Working Voltage
LED
Leakage Current
LED
110...600V AC/DC or
1272V DC
110...600V AC/DC or
12...72V AC/DC
110...600V AC/DC
2.0 mA
Wire Size
#164 AWG Cu
2...2.5 Nm
(18...22 lbin)
2...2.5 Nm
(18...22 lbin)
Terminal Torque
#141 AWG Cu
#10...1 AWG Cu
#164 AWG Cu
4
Accessories
Description
Pkg. Quantity
Cat. No.
1492-MC5X5
1492-MC6X5
6
7
Approximate Dimensions
Dimensions are in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Height
9
Depth
10
11
Width
Width
60 A
30 A
One-Pole
Two-Pole
Three-Pole
12
13
Visit our website: www.ab.com/catalogs
7-30
30 A
05_140F.qxd
4/25/2008
1:28 PM
Page 7-31
Bulletin 140F
Fuse Holders
Overview/Product Selection/Wiring Diagrams
Bulletin 140F Fuse Holders
y Available for UL Class CC or Midget Fuses and IEC 10 x 38 mm fuses, with or without
blown fuse indication
y Lockable in the open position
y Compatible with Bulletin 140M accessories
y Compact busbar and connectors for Bulletin 100-C and 100-K contactors
y 1 N.O./1 N.C. Auxiliary Contactlate make N.O., early break N.C.
Provides capability for dropping out contactor before breaking current on fuses
Late make N.O. contact provides positive indication that power circuit is open
Description
Voltage Rating,
Max.[V]
Approvals
IEC
CE Mark
UL
CSA
140F-D3C-C30L
200
600
Yes
Yes
Yes
140F-D3M-C30
140F-D3M-C30L
Yes
140F-D3F-C30
140F-D3C-C30
Cat. No.
200
690
No
No
Yes
Yes
140F-D3F-C30L
140F-C-AFA11
For additional accessories, refer to Bulletin 100-C/100-K contactors and Bulletin 140M circuit breakers.
UL/CSA (ANSI)
6
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-31
05_140F.qxd
4/25/2008
1:28 PM
Page 7-32
Bulletin 140F
Fuse Holders
Wiring Diagrams, Continued/Approximate Dimensions
IEC
!
1
5
15
27
16
28
1
F1
2
2
3
A1
4
K1
2
A2
Dimensions are in inches (mm). Dimensions are not to be used for manufacturing purposes.
2.27
(57.7)
7
3.54
(89.9)
1.66
(42.1)
0.10
(2.5)
9
0.18
(4.5)
10
11
1.91
(48.5)
2.82
(71.5)
1.00
(25.3)
0.61
(15.5)
2.85
(72.4)
0.30
(7.5)
2.58
(65.5)
1.23
(31.2)
12
1.77
(45)
13
Visit our website: www.ab.com/catalogs
7-32
06_1492CB.qxd
4/25/2008
1:22 PM
Page 7-33
Bulletin 1492-CB
Table of Contents
Product Selection ...... 7-34
Specifications.............. 7-35
Approximate
Dimensions................... 7-35
Standards Compliance
!
1
UL 1077
CSA C22.2 No. 235
IEC/EN 60950, 60934
Certifications
UL Recognized Component
UL Certified Component
CE Marked
y Solenoids
y Test Equipment
y Controller I/O Points
y Relay and Contactor Coils
y Computers
y Automotive Systems
y Medical Equipment
y Control Instrumentation
4
5
Trip Curves
6
7
8
9
10
Multiple of Rated Current (xI n)
DF-Trip Curve
4.58
DG-Trip Curve
9.016
DH-Trip Curve
1832
11
12
13
7-33
06_1492CB.qxd
4/25/2008
1:22 PM
Page 7-34
Bulletin 1492-CB
Tripping Characteristic
Number of Poles
Cat. No.
Cat. No.
1492-CB1DF010
1492-CB1DG010
1492-CB1DF020
1492-CB1DG020
1492-CB1DF030
1492-CB1DG030
1492-CB1DF040
1492-CB1DG040
1492-CB1DF050
1492-CB1DG050
1492-CB1DF060
1492-CB1DG060
1492-CB2DH060
1492-CB1DF070
1492-CB1DG070
1492-CB2DH070
1492-CB1DF080
1492-CB1DG080
1492-CB2DH080
10
1492-CB1DF100
1492-CB1DG100
1492-CB2DH100
12
1492-CB1DF120
1492-CB1DG120
1492-CB2DH120
15
1492-CB1DF150
1492-CB1DG150
1492-CB2DH150
16
1492-CB1DF160
1492-CB1DG160
1492-CB2DH160
20
1492-CB1DF200
1492-CB1DG200
1492-CB2DH200
25
1492-CB1DF250
1492-CB1DG250
1492-CB2DH250
30
1492-CB1DF300
1492-CB1DG300
1492-CB2DH300
32
1492-CB1DF320
1492-CB1DG320
1492-CB2DH320
40
1492-CB1DF400
1492-CB1DG400
1492-CB2DH400
DF Trip
Resistive or Slightly
Inductive
DG Trip
Inductive
DH Trip
Highly Inductive
4.58 In
916 In
1832 In
Tripping Characteristic
8
9
10
1832 In
1492-CB1DG005
916 In
Cat. No.
2-Pole
1 Piece per Carton
4.58 In
1492-CB1DF005
Number of Poles
DH Trip
Highly Inductive
0.5
DG Trip
Inductive
1-Pole
1 Piece per Carton
DF Trip
Resistive or Slightly
Inductive
Cat. No.
Cat. No.
Cat. No.
0.5
1492-CB2DF005
1492-CB2DG005
1492-CB2DF010
1492-CB2DG010
1492-CB2DF020
1492-CB2DG020
1492-CB2DF030
1492-CB2DG030
1492-CB2DF040
1492-CB2DG040
1492-CB2DF050
1492-CB2DG050
1492-CB2DF060
1492-CB2DG060
1492-CB2DH060
1492-CB2DF070
1492-CB2DG070
1492-CB2DH070
1492-CB2DF080
1492-CB2DG080
1492-CB2DH080
10
1492-CB2DF100
1492-CB2DG100
1492-CB2DH100
12
1492-CB2DF120
1492-CB2DG120
1492-CB2DH120
15
1492-CB2DF150
1492-CB2DG150
1492-CB2DH150
16
1492-CB2DF160
1492-CB2DG160
1492-CB2DH160
20
1492-CB2DF200
1492-CB2DG200
1492-CB2DH200
25
1492-CB2DF250
1492-CB2DG250
1492-CB2DH250
30
1492-CB2DF300
1492-CB2DG300
1492-CB2DH300
32
1492-CB2DF320
1492-CB2DG320
1492-CB2DH320
40
1492-CB2DF400
1492-CB2DG400
1492-CB2DH400
11
12
13
Visit our website: www.ab.com/catalogs
7-34
06_1492CB.qxd
4/25/2008
1:22 PM
Page 7-35
Bulletin 1492-CB
Auxiliary Contacts
Cat. No.
1 N.O. Contact
1 N.C. Contact
1492-ACBH2
1 N.O. Contact
1 N.C. Contact
1492-ACBS1
1492-ACBS2
512V AC/DC
1492-ACBA1
1024V AC/DC
1492-ACBA2
2048V AC/DC
1492-ACBA3
40110V AC/DC
1492-ACBA4
90240V AC/DC
1492-ACBA5
1492-ACBH1
Cat. No.
199-DR1
10
End Anchor
10
1492-EAH35
Lockout Attachment
1492-ACBLOA
Bus Bars
2
3
4
Specifications
Description
Tripping Characteristic
DF Curve
DG Curve
DH Curve
Inductive Loads
Highly-Inductive Loads
916 In
1832 In
4.58 In
Dielectric Strength
1960V AC
Shock
Vibration
Operating Temperature Range
40+185 F (40+85 C)
Housing Material
Melamine-Phenolic
Wire Size
mm2)
Up to 6 A, 50 000 cycles
716 A, 30 000 cycles
2032 A, 20 000 cycles
4050 A, 12 000 cycles
277V AC, 6 A
125V AC, 1 A
50V DC, 6 A
10 kA @ 120V DC U1
10 kA @ 120V DC U1
5 kA @ 240V DC U1
2-Pole in Series
10 kA @ 240V DC U1
10 kA @ 240V DC U1
5 kA @ 240V DC U1
Approximate Dimensions
Dimensions are shown in inches (millimeters). Dimensions are not intended
for manufacturing purposes.
Number of
Poles and
Accessories
Width (inches)
0.7
1.4
2.1
2.8
3.5
Width
(millimeters)
17.8
35.6
53.3
71.1
88.9
10
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-35
07_1492GH_1492GS.qxd
4/25/2008
1:29 PM
Page 7-36
!
1
2
Table of Contents
Standards Compliance
UL 1077
CSA C22.2 No 235
EN/IEC 60934
Certifications
UL Recognized Component
CSA Recognized Component
CE Marked
Bulletin 1492 high density miniature circuit breakers are thermal magnetic type supplementary overcurrent protective devices. Bulletin 1492GH miniature circuit breakers are available in one-pole units. Bulletin 1492-GS are available in one-, two-, and three-pole. These breakers are
often used when panel space (width) is a premium. These products include a high density design. Up to 24 one-pole breakers can be
mounted per foot. The Bulletin 1492-GS breaker can be ordered with auxiliary contacts that do not add any additional space. Wire
termination is achieved by a clamping style, self-lifting box lug.
Applications
1492-GH
1492-GS
5
6
7
8
9
10
11
12
13
7-36
07_1492GH_1492GS.qxd
4/25/2008
1:29 PM
Page 7-37
70 F
(21.1 C)
100 F
(37.8 C)
120 F
(48.9 C)
140 F
(60 C)
160 F
(71.1 C)
180 F
(82.2 C)
200 F
(93.3 C)
1.0
1.1
1.2
1.3
1.4
1.5
1.6
!
1
100%
200%
300%
400%
500%
600%
1000%
2000%
Greater
Tripping Times
(Seconds)
No Trip
1040
318
1.59
0.86
0.0034
0.0092
Max.
0.02
Note: When several breakers are rail mounted adjacent to each other, the no-trip current will be 80% of rated current at 70 F (21.1 C).
Using selection table on page 7-38 select Bulletin 1492-GH/GS that allows full load current nearest without exceeding application current.
Also, check that inrush current is less than trip range of 610 In.
1492-GH/GS
To select a miniature circuit breaker, use the following procedure:
1. Determine the inrush correction factor from the following table.
1:1 to 1:4
1:5
1:6
1:7
1:8
1.3
1.4
1.5
1.6
1.7
6
7
8
9
10
11
12
13
7-37
07_1492GH_1492GS.qxd
4/25/2008
1:29 PM
Page 7-38
2-Pole
3-Pole
Amperage [A]
Cat. No.
Cat. No.
Cat. No.
Cat. No.
0.2
1492-GH002
1492-GS1G002
1492-GS2G002
1492-GS3G002
0.5
1492-GH005
1492-GS1G005
1492-GS2G005
1492-GS3G005
0.8
1492-GH008
1492-GS1G008
1492-GS2G008
1492-GS3G008
1.0
1492-GH010
1492-GS1G010
1492-GS2G010
1492-GS3G010
1.2
1492-GH012
1492-GS1G012
1492-GS2G012
1492-GS3G012
1.5
1492-GH015
1492-GS1G015
1492-GS2G015
1492-GS3G015
2.0
1492-GH020
1492-GS1G020
1492-GS2G020
1492-GS3G020
2.5
1492-GH025
1492-GS1G025
1492-GS2G025
1492-GS3G025
3.0
1492-GH030
1492-GS1G030
1492-GS2G030
1492-GS3G030
4.0
1492-GH040
1492-GS1G040
1492-GS2G040
1492-GS3G040
5.0
1492-GH050
1492-GS1G050
1492-GS2G050
1492-GS3G050
6.0
1492-GS1G060
1492-GS2G060
1492-GS3G060
7.0
1492-GH070
1492-GS1G070
1492-GS2G070
1492-GS3G070
8.0
1492-GS1G080
1492-GS2G080
1492-GS3G080
10.0
1492-GH100
1492-GS1G100
1492-GS2G100
1492-GS3G100
12.0
1492-GS1G120
1492-GS2G120
1492-GS3G120
15.0
1492-GH150
1492-GS1G150
1492-GS2G150
1492-GS3G150
16.0
1492-GS1G160
1492-GS2G160
1492-GS3G160
20.0
1492-GS1G200
1492-GS2G200
1492-GS3G200
25.0
1492-GS1G250
1492-GS2G250
1492-GS3G250
!
1
2
3
4
5
1492-GS
1-Pole
Specifications
1492-GH
6
UL/CSA
1492-GS
1-Pole
1-Pole
200 A
(Not to exceed 100 x rated A)
0.216 A
1825 A
2 kA C1
400 A
625 A
800 A
480Y/277V AC 50/60 Hz
65V DC
Operating Life
Housing Material
Shock
25 G, 11 ms duration
Vibration
Dielectric Strength
5 G (10500 Hz)
1500V AC
1600V AC
100 M @ 500V DC
Insulation Resistance
Terminal Type
Wire Size
10
3-Pole
0.25 A
250V AC 50/60 Hz
65V DC
Temperature Range
2-Pole
#2210 AWG
0.44 in. (11.2 mm)
Main Term 0.51 in. (13 mm) Aux Term 0.41 in. (10.4 mm)
0.656 Nm (5 lbin)
11
Approximate Dimensions
1492-GH
1-Pole
12
Height
1492-GS
1-Pole
Depth
Width
3-Pole
13
Visit our website: www.ab.com/catalogs
7-38
2-Pole
08_1492SP.qxd
4/25/2008
1:31 PM
Page 7-39
Bulletin 1492-SP
Table of Contents
!
Product Selection ...... 7-40
Specifications.............. 7-44
Approximate
Dimensions................... 7-45
Standards Compliance
UL 1077
CSA C22.2 No. 235
IEC/EN 60898, 60947-2
UL File Number E65138
1
2
Certifications
UL Recognized
CSA Certified
CE Marked
Germanischer Lloyd (Marine)
Bulletin 1492-SP series C devices are energy limiting, thermal magnetic type overcurrent protectors meeting UL 1077/CSA C22.2 No. 235,
IEC/EN 60898. These devices are designed for the protection of a wide variety of products including:
y Solenoids
y Test Equipment
The Bulletin 1492-SP supplementary protectors/miniature circuit breakers are available in one-, onepole plus neutral, two-, three-, and three-pole plus neutral units. One- and two-pole AC units also have y Controller I/O Points
limited DC ratings. Two- and three pole units are connected at the handle for simultaneous operation. y Relay and Contractor Coils
Screw termination is standard on all Bulletin 1492-SP units. Both line and load side terminals accept
y Computers
#164 AWG (1.525 mm2) copper wire.
y Transformers
y Automotive Systems
y Power Supplies
y Medical Equipment
y Control Instrumentation
4
5
6
7
8
9
10
11
12
13
7-39
08_1492SP.qxd
4/25/2008
1:31 PM
Page 7-40
Bulletin 1492-SP
Tripping Characteristics
Number of Poles
1-Pole
2
3
IEC 240/415V AC
UL/CSA 277V AC 48V DC
4
5
Trip Curve B
Resistive or Slightly Inductive
Trip Curve C
Inductive
Trip Curve D
Highly Inductive
35 In
510 In
1020 In
Continuous
Current
Rating (In) [A]
Cat. No.
Cat. No.
Cat. No.
0.5
1492-SP1C005
1492-SP1D005
1492-SP1B010
1492-SP1C010
1492-SP1D010
1492-SP1B020
1492-SP1C020
1492-SP1D020
1492-SP1B030
1492-SP1C030
1492-SP1D030
1492-SP1B040
1492-SP1C040
1492-SP1D040
1492-SP1B050
1492-SP1C050
1492-SP1D050
1492-SP1B060
1492-SP1C060
1492-SP1D060
1492-SP1B070
1492-SP1C070
1492-SP1D070
1492-SP1B080
1492-SP1C080
1492-SP1D080
10
1492-SP1B100
1492-SP1C100
1492-SP1D100
13
1492-SP1B130
1492-SP1C130
1492-SP1D130
15
1492-SP1B150
1492-SP1C150
1492-SP1D150
16
1492-SP1B160
1492-SP1C160
1492-SP1D160
20
1492-SP1B200
1492-SP1C200
1492-SP1D200
25
1492-SP1B250
1492-SP1C250
1492-SP1D250
30
1492-SP1B300
1492-SP1C300
1492-SP1D300
32
1492-SP1B320
1492-SP1C320
1492-SP1D320
40
1492-SP1B400
1492-SP1C400
1492-SP1D400
50
1492-SP1B500
1492-SP1C500
63
1492-SP1B630
1492-SP1C630
Note: Bulletin 1492-SP 1- and 3-pole circuit breakers are also available with neutral. Add a suffix of -N to the cat. no.
6
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
7-40
08_1492SP.qxd
4/25/2008
1:32 PM
Page 7-41
Bulletin 1492-SP
Tripping Characteristics
Trip Curve B
Resistive or Slightly Inductive
Trip Curve C
Inductive
Trip Curve D
Highly Inductive
35 In
510 In
1020 In
Number of Poles
Continuous
Current
Rating (In) [A]
Cat. No.
Cat. No.
Cat. No.
2-Pole
0.5
1492-SP2C005
1492-SP2D005
1492-SP2B010
1492-SP2C010
1492-SP2D010
1492-SP2B020
1492-SP2C020
1492-SP2D020
1492-SP2B030
1492-SP2C030
1492-SP2D030
1492-SP2B040
1492-SP2C040
1492-SP2D040
1492-SP2B050
1492-SP2C050
1492-SP2D050
1492-SP2B060
1492-SP2C060
1492-SP2D060
1492-SP2B070
1492-SP2C070
1492-SP2D070
1492-SP2B080
1492-SP2C080
1492-SP2D080
10
1492-SP2B100
1492-SP2C100
1492-SP2D100
13
1492-SP2B130
1492-SP2C130
1492-SP2D130
15
1492-SP2B150
1492-SP2C150
1492-SP2D150
16
1492-SP2B160
1492-SP2C160
1492-SP2D160
20
1492-SP2B200
1492-SP2C200
1492-SP2D200
25
1492-SP2B250
1492-SP2C250
1492-SP2D250
30
1492-SP2B300
1492-SP2C300
1492-SP2D300
32
1492-SP2B320
1492-SP2C320
1492-SP2D320
40
1492-SP2B400
1492-SP2C400
1492-SP2D400
50
1492-SP2B500
1492-SP2C500
63
1492-SP2B630
1492-SP2C630
0.5
1492-SP3C005
1492-SP3D005
1492-SP3B010
1492-SP3C010
1492-SP3D010
1492-SP3B020
1492-SP3C020
1492-SP3D020
1492-SP3B030
1492-SP3C030
1492-SP3D030
1492-SP3B040
1492-SP3C040
1492-SP3D040
1492-SP3B050
1492-SP3C050
1492-SP3D050
1492-SP3B060
1492-SP3C060
1492-SP3D060
1492-SP3B070
1492-SP3C070
1492-SP3D070
1492-SP3B080
1492-SP3C080
1492-SP3D080
10
1492-SP3B100
1492-SP3C100
1492-SP3D100
13
1492-SP3B130
1492-SP3C130
1492-SP3D130
15
1492-SP3B150
1492-SP3C150
1492-SP3D150
16
1492-SP3B160
1492-SP3C160
1492-SP3D160
20
1492-SP3B200
1492-SP3C200
1492-SP3D200
25
1492-SP3B250
1492-SP3C250
1492-SP3D250
30
1492-SP3B300
1492-SP3C300
1492-SP3D300
32
1492-SP3B320
1492-SP3C320
1492-SP3D320
40
1492-SP3B400
1492-SP3C400
1492-SP3D400
50
1492-SP3B500
1492-SP3C500
63
1492-SP3B630
1492-SP3C630
IEC
415V AC
UL/CSA
480Y/277V AC
125V DC
3-Pole
IEC
415V AC
UL/CSA
480Y/277V AC
!
1
2
3
4
5
6
7
8
9
10
Note: 1492-SP 1- and 3-pole circuit breakers are also available with neutral. Add a suffix of -N to the cat. no.
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-41
08_1492SP.qxd
4/25/2008
1:32 PM
Page 7-42
Bulletin 1492-SP
1492-ASPH3
1492-ASPHH3
1492-ASPHS3
50115V AC
110240V AC
1492-ASPU115
1492-ASPU230
1492-ASPA1
1492-ASPA2
!
1
Auxiliary Contacts
2
3
4
Mounting Rail
Cat. No.
Pkg Qty: 10
199-DR1
1492-EAH35
Pkg Qty: 5
1492-ASPLOA
End Anchor
Lockout Attachment
6
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
7-42
08_1492SP.qxd
4/25/2008
1:32 PM
Page 7-43
Bulletin 1492-SP
Type
Rated
Operational
Ia
Rated Operational Ie
End Feed per phase
Rated Operational
Ie Center Feed per
phase (Is < 63 A)
Pieces Per
Package
Cat. No.
Fork Style Commoning Links (may be cut to length, not for use with accessories)
1 pole
1 m (56
devices/m)
63
63
100
1492-ASPCL1
3 poles
1 m (19
devices/m)
63
63
100
1492-ASPCL3
10
1492-ASPEC1
Fork Style Commoning Links (may NOT be cut to length, not for use with accessories)
1 pole
85
63
100
1492-ASPCL102
1 pole
85
63
100
20
1492-ASPCL106
1 pole
12
85
63
100
20
1492-ASPCL112
2 poles (1p + N)
120
63
100
10
1492-ASPCL204
2 poles (1p + N)
120
63
100
10
1492-ASPCL206
2 poles (1p + N)
120
63
100
10
1492-ASPCL212
3 poles
120
63
100
10
1492-ASPCL306
3 poles
120
63
100
10
1492-ASPCL312
4 poles
120
63
100
1492-ASPCL408
4 poles
120
63
100
1492-ASPCL412
2
3
4
85
63
100
20
1492-ASPCL1A02
1 pole
85
63
100
20
1492-ASPCL1A06
1 pole
85
63
100
20
1492-ASPCL1A09
2 poles (1p + N)
120
63
100
10
1492-ASPCL2A04
2 poles (1p + N)
120
63
100
10
1492-ASPCL2A06
2 poles (1p + N)
120
63
100
10
1492-ASPCL2A10
3 poles
120
63
100
10
1492-ASPCL3A06
3 poles
120
63
100
10
1492-ASPCL3A12
63
100
10
1492-ASPCL3AP06
5
6
2x3 (1p)
2x3 (1p)+2
(1p)
120
120
63
100
10
1492-ASPCL3AP08
3x3 (1p)
120
63
100
10
1492-ASPCL3AP09
Incoming Terminals for Fork Style (not for use in North America)
For max 25 mm2 wire
100
50
1492-ASPCLT25
100
10
1492-ASPCLT35
100
10 sets
(5/set)
1492-ASPCLPS
8
9
Center Feed
End Feed
Is
Is2
10
Is1
Ie = Is1 + Is2
Is < 63 A
11
Ie = Is
Ie
Ie
Note: Ie - for center feed above 63 A use Cat. No. 1492-ASPCLT35 terminal
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-43
08_1492SP.qxd
4/25/2008
1:32 PM
Page 7-44
Bulletin 1492-SP
1492-SP Series C
Description
Tripping Characteristics
Current Range
B Curve
C Curve
D Curve
Resistive or Slightly-Inductive
Loads
Inductive Loads
Highly-Inductive Loads
35 In
510 In
1020 In
163 A
0.563 A
0.540 A
1, 2, 3, 1 +N, 3 + N
Dielectric Strength
1960V AC
Shock
Vibration
Operating Temperature Range
40+185 F (40+85 C)
Housing Material
Nylon
#184 AWG (1.010 mm2)
Tightening Torque 2.4 Nm (21 lbin.)
Wire Size
Electromechanical Life
277V AC
Supplementary Protector
UL 1077 - Recognized Component QVNU2 - E65138
CSA C22.2 No. 235 Certified Component
Certifications
Use Group (UG)
UG A - General Industrial
Terminals (FW)
OL 0 (general use)
1-Pole, 1-Pole + N
Maximum Volts
7
8
277V AC
48V DC
TC 1, 40 C
TC 1, 40 C
SC U2
SC U1
< 35 A
40, 50, 63 A
480Y/277V AC
Tripping Current
TC 2, 40 C
TC 2, 40 C
SC U2
SC U1
< 35 A
40, 50, 63 A
10
11
12
13
Visit our website: www.ab.com/catalogs
7-44
08_1492SP.qxd
4/25/2008
1:32 PM
Page 7-45
Bulletin 1492-SP
!
Undervoltage Release Module
Cat. Nos.
1492-ASPU115
1492-ASPU230
Degree of Protection
IP20 (IP00)
Dimensions
See below
Weight
0.045 kg
0.155 kg
0.155 kg
6000 operations
10 000 operations
4000 operations
> 15 ms
1492-ASPU115:
Un-115V AC, Umin-50V AC
1492-ASPA1:
110415V AC, 110230V
AC
1492-ASPU230:
Un-230/240V AC, Umin-110V AC
1492-ASPA2:
12110V AC, 1260V AC
Inrush Current
3.6/44 mA (AC/DC)
25/12 mA (AC)
15/2 mA (DC)
Dropout
0.70.35 x Us
Voltage Range
0.71.1 x Us
AC 13 @ 250V AC 3 A
AC 15 @ 250V AC 0.5 A
DC 12 @ 110V DC 0.5 A
Umin-5V AC
Terminal Capacity
IEC Rigid, CU
0.52.5 mm2
2 x 0.52 x 2.5 mm2
0.54.0 mm2
2 x 0.52 x 2.5 mm2
1.025 mm2
2 x 1.02 x 4.0 mm2
Tightening Torque
0.8 Nm
1.1 Nm
2.4 Nm
@ 230V AC 2 A
@ 110V DC 0.5 A
Umin-5V CDC
#1814 AWG
2 x #182 x #14 AWG
#1814 AWG
2 x #182 x #14 AWG
#188 AWG
2 x 182 x #12 AWG
7 lbin.
10 lbin.
21 lbin.
Mechanical Lifespan
Minimum Impulse Duration
Operating Voltage
Max. Operating
Current
EN/IEC
Max. Operating
Current
UL 1077
CSA C22.2 No. 235
Terminal Capacity CU
Tightening Torque
2
3
4
5
6
7
Approximate Dimensions
Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes.
8
9
10
Bulletin 1492-SP
11
12
Cat. No.
1492-ASPHH3
1492-ASPHS3
1492-ASPH3
13
7-45
08_1492SP.qxd
4/25/2008
1:32 PM
Page 7-46
Bulletin 1492-SP
L1 L2 L3 L1 L2 L3
17.8 mm
1
2
17.8 mm
1m
1m
NOT be cut:
1492-ASPCL1A06
L1
L1 L1
L1
L1
1492-ASPCL1A09
L1
L1
L1
L1
L1
3
26.5
mm
1492-ASPCL2A04
L1
L1
L2
1492-ASPCL2A06
1492-ASPCL2A10
L1
L1
L2
L1
L2
L2
26.5
mm
26.5
mm
26.5
mm
1492-ASPCL3A04
L1
L2
L3
L1
1492-ASPCL3A12
L2
L1
L3
L2
L3
L1
1492-ASPCL3AP04
L1
L2
L3
L2
52.5 mm
52.5 mm
L1
L2
35
mm
35
mm
35
mm
26.5
mm
26.5
mm
L3
L1
1492-ASPCL3AP08
L2
L3
L1 L2
L3
L1
L2
L3
L1
L2
10
26.5
mm
26.5
mm
26.5
mm
26.5
mm
11
1492-ASPCL3AP09
L1
12
L2
L3
L3
L1
L1
L2
L2
26.5
mm
13
26.5
mm
7-46
08_1492SP.qxd
4/25/2008
1:33 PM
Page 7-47
Bulletin 1492-SP
page 4 of 4
6-Nov-06
2
3
4
5
6
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
Preferred availability cat. nos. are printed in bold
7-47
08_1492SP.qxd
4/25/2008
1:33 PM
Page 7-48
Bulletin 1492-SP
!
1
2
3
4
5
6
7
8
9
10
11
12
13
Visit our website: www.ab.com/catalogs
7-48