Mac
Mac
Mac
MAC-Series
10 TR thru 70 TR
(Provisional catalogue)
CONTENTS
Outstanding features
Model Decoding
Standard specification / options/ accessories
Capacity range
Physical data
Operation and control system
Dimensional Drawings
Schematic diagram
B: Commercial
A: Industrial
APPLICTION
B: Semi
hermetic
reciprocating
A: Scroll
COMPRESSOR
TYPE
L:380/415-3-50
(4 WIRE)
F- 460-3-60
M- 380-3-60
( 4-WIRES)
H-208/230-3-60
ELECTRICAL
SUPPLY
(V-Ph-Hz)
10
C: Copper fin
B: Pre-coated
Aluminium fin
A: Aluminium fin
CONDENSER
TYPE
11
C: Copper fin
B: Pre-coated
Aluminium fin
A: Aluminium fin
EVAPORATOR
TYPE
12
2.
COMPUTER SELECTED DEGITS (FROM `AA TO `ZZ) DESCRIBING OTHER OPTION & ACCESSORIES
OR COMBINATIONS SUCH AS
13
SEE NOTE #2
OPTION
& ACCESSORIES
NOTE
1. COMPRESSOR CAN ETHER BE SCROLL OR SEMI HERMETIC RECIPROCATING DEPONDING UPON PROJECTS REQUIREMENTS.
070
060
050
045
040
035
030
025
020
018
015
B: R134a
012
Mobile
Air
conditioning
System
A:R-22
010
MAC
REFRIGERANT
NOMINAL
COOLING
CAPACITY
BASIC
(SERIES)
4,5 & 6
1,2 & 3
MODEL DECODING
STANDARD SPECIFICATION
GENERAL
The Zamil mobile air-conditioning system consists of a packaged type air-conditioner that is mounted on a
movable platform such as a trailer. It includes a power generation unit and the air-conditioning unit encased
in one complete enclosure. The power generation unit is a diesel generator. The unit also includes a variable
frequency drive (optional) that modulates the fan blower motor to provide a gradual increase of supply air
up to a fixed value.
These systems are broadly classified into two groups depending on the application.
1. Industrial System
Such systems are mainly used for high static application such as hydrocarbon, petrochemical plants,
airport ground support and shipyardetc.
2. Commercial System
Such systems are mainly used for low static application such as industrial plants , utilities, buildings,
hospital and emergency cooling.etc.
This catalogue contains 18 and 25 ton model details. The remaining models are now in the
conceptual design stage when technical data is ready the catalogue will be updated accordingly.
Engineering is ready to support custom made products tailored for specific application. Please
consult Zamil Air Conditioner sales office for details.
EVAPORATOR FAN
Heavy-duty high pressure backward radial fan is capable of supplying required airflow & static pressure.
The fan discharge outlet can be connected to a flexible pre conditioned delivery hose (optional). Flexible
duct is constructed by two-ply, abrasion resistant fabrics or PVC coated fabrics and is stowed inside the unit,
when not in use.
EVAPORATOR/CONDENSER COIL
Coils are made with corrugated fins and seamless 3/8 or diameter copper tube. The mechanically
bounded enhanced fins enable maximum heat transfer efficiency. Evaporator and Condenser coils are tested
in the factory at 300 PSI & 450 PSI air pressure respectively. Copper or Coated Aluminium fins can be used
as an option. Coils conform to ARI standard 410.
STANDARD OPTIONS
1) Control panel
The control panel design is equivalent to NEMA 4 standard with hinged door for easy access ensuring dust
and weatherproof construction. Internal power and control wiring is neatly routed, properly anchored and all
wires are identified with cable markers as per NEC standard applicable to HVAC units. The electrical
controls used in the control panel are UL approved, and are reliable in operation at high ambient conditions
for a long period.
OPEN
450 PSIG
CLOSE
360 15 PSIG
OPEN
25 5 PSIG
CLOSE
50 5 PSIG
8) Crankcase Heaters
Each compressor has crankcase heater. The compressor crankcase heater is always on when the compressor
is de-energized. This protects the system against refrigerant migration, oil dilution and potential compressor
failure.
9) Service Lamps
Two 60watts/220v service lamps are provided in the unit: in supply fan motor section and in the generator
engine section, for illumination purpose in case repairs are needed
3) Electric heaters
Electric heaters are of the resistance open coil type and conform to the requirements of UL 573 or
equivalent. Electrical characteristics, kW capacities and number of stages are as indicated. Thermal cut-outs,
fusible links and airflow switches are provided to shut-off power to heaters in case of airflow failure.
PHYSICAL DATA
MODEL NUMBER *
MAC-18
MAC-25
18
24
16
21
APPLICATION *
COMMERCIAL
100% FRESH AIR
INDUSTRIAL
100% FRESH AIR
REFRIGERANT
R 22
R 22
SCROLL
SCROLL
COMPRESSOR
TYPE
MODEL / PART NO. (QTY) STD
(STANDARD UNIT)
800-674-81 (2)
800-674-19 (2)
V-Ph-Hz
460-3-60
460-3-60
RLA/LRA
16/95
19.6/125
OPERATING CHARGE/SYSTEM
(OZ.)
290
TYPE
PROPELLER
PROPELLER
800-237-04(2)
800-237-03(2)
NOMINAL CFM
10000
15000
DIAMETER (mm)
630 mm
700 mm
V-Ph-Hz
MOTOR kw - RPM-FLALRA
460-3-60
460-3-60
50.9
68.2
60
80
37.3
50.43
3/8-4-14
3/8-5-14
CONDENSER COIL
EVAPORATOR BLOWER
TYPE
TUBE DIA. - ROWS - FINS PER
INCH
TOTAL FACE AREA
(SQ.FT)
TYPE
SIZE
(INCH)
DRIVE
TYPE
NOMINAL CFM
MOTOR KW - STD
EVAPORATOR
BLOWER MOTOR
FLA/LRA
MOTOR FRAME
EVAPORATOR COIL
450
TYPE
TUBE DIA. - ROWS - FINS PER
INCH
TOTAL FACE AREA
(SQ.FT)
18
25
FARWARD CURVED
BACKWARD CURVED
250
DP/500
BELT DRIVE
DRIECT DRIVE
1,800
2,400
1.5KW(80100945)
13.2 kw
3.35/ 17
21 /111
IEC
IEC
1/2-8-12
1/2-12-10
OPEN
450 10 PSIG
450 10 PSIG
CLOSE
360 15 PSIG
360 15 PSIG
OPEN
25 5 PSIG
25 5 PSIG
CLOSE
50 5 PSIG
50 5 PSIG
10
A) Sequence of Operation
System Start-Up:
Starting the generator engine is accomplished manually by setting the OFF / GEN RUN / FAN
selector switch to GEN RUN position. Once the generator has started and reached its normal operating
speed, set the selector switch to FAN to activate the controlled operation of the supply fan motor. The
cooling system is started next through VENT / COOL selector switch by setting this to COOL position.
(In VENT position, supply fan is active but cooling system is off.). Next, select the desired degree of
cooling through the LOW / MED / HIGH selector switch.
Cooling Modes:
Cooling is accomplished by cycling the two compressors ON and OFF to maintain the desired supplied
air temperature set point as selected by the user. The compressors are also cycled to operate as leading or
lagging to equalize their operating time. Depending on the selected degree of cooling, the cycling of the
compressors will be based on timing and outdoor air temperature with the supply air temperature as
safety limit. Compressor operating sequences are as follows:
Low Cooling Mode Compressors operate alternately with ON timing of ten (10) minutes and OFF
timing of three (3) minutes. If the supply air temperature goes down below 8C and this level is
maintained for three (3) minutes or if temperature drops further down to 6 C, the controller will shut off
the compressors. Compressors will resume operation only when a timing of three (3) minutes has lapsed
and with supply air temperature above 12 C.
11
Medium Cooling Mode Both compressors are operated on an alternating sequence with three (3)
minutes overlap. Each compressor operates with ten (10) minutes run time and four (4) minutes off time.
Two compressors run at the same time for three minutes in each seven (7) minute time intervals. . If the
supply air temperature goes down below 8 C and this level is maintained for three (3) minutes or if
temperature drops further down to 6 C, the controller will shut off the compressors. Compressors will
resume operation only when a timing of three (3) minutes has lapsed and with supply air temperature
above 12 C.
High Cooling Mode - Both compressors are operated on an alternating sequence with thirteen and threefourths (13.75) minutes overlap. Each compressor operates with thirty two and a half (32.5) minutes run
time and five (5) minutes off time. Two compressors run at the same time for thirteen and three-fourths
(13.75) minutes in each eighteen and three-fourth (18.75) minutes time intervals. . If the supply air
temperature goes down below 8C and this level is maintained for three (3) minutes or if temperature
drops further down to 6 C, the controller will shut off the compressors. Compressors will resume
operation only when a timing of three (3) minutes has lapsed and with supply air temperature above 12
C.
12
B) SYSTEM SAFETY
Emergency Shutdown
An emergency push button switch is provided and fixed in an accessible location on the main control
panel to shut-off the generator and ACU in case of an emergency. Switch is to be pulled back to its
normal position to return the unit in ready-to-operate condition.
System Fault Indicators
System faults are monitored by the units controller and an indicator lamp in the control panel will light
corresponding to the fault. The following are the system faults:
a) Generator Fault
b) Low Fuel
c) ACU Fault
d) Compressor 1 Fault
e) Compressor 2 Fault
f) No Air Flow
Other system faults are also monitored and will be shown in the user interface boards LED in the
control panel. These are: VFD fault, low pressure & high pressure faults. In case one compressor has
tripped, the other compressor will continue to run and an alarm indication will be energized.
Compressor Lock-out
Each system compressor will lock-out if one of the following conditions arise:
a) Compressor fault is maintained for three minutes
b) Fault occurs twice in a thirty (30) minutes span
c) Compressor is running for two (2) minutes and still the supply air temperature is equal to or
above outdoor temp less 2 C.
Interlock (Operating) Conditions
1.Supply fan will operate if the following conditions are met:
a) No VFD fault
b) Power is supplied for one (1) minute
c) Selector switch OFF / GEN RUN / FAN is set to fan
2.Supply Fan Speed Operation
a) Minimum of 20Hz frequency
b) Modulates from 20 to 60 Hz base on CFM set point of 2200 CFM provided supply static
pressure is below 21 WG.
c) Supply fan speed is maintained and prevented to increase further when supply static
pressure reaches 21 WG.
3.Compressors will operate if the following conditions are met:
a) Selector switch VENT / COOL is set to COOL position
b) Supply fan motor is active
c) Ambient temperature is 16C
d) No faults in compressors
e) Air flow is above 2100 CFM
f) Supply air temperature is above 12 C
g) Compressor OFF time of three (3) minutes has lapsed.
13
640 [25.22]
TRAILER
GENERATOR
MUFFLER
CONDENSOR COIL
CONDENSOR FAN
EVAPORATOR COIL
FILTER
COTROL BOX
BLOWER
1362.4 [53.63]
1332.7 [52.48]
3600 [141.76]
2210 [86.98]
1502.1 [59.14]
~ 800.1 [31.49]
14
RADIATOR
AIR OUT
SUPPLY AIR
FRESH
AIR IN
529 [20.8]
15
SCHEMATIC DIAGRAM
POWER SUPPLY
PACKAGE ACU
460V-3PH-60HZ
CB6
HVTB
L1
POWER SUPPLY
(GEN SET PANEL)
L1
L2
L2
L3
L3
LUG/ETB
CB3
CB2
CB4
CB5
ST1
(MB)
OLR1
OLR2
FMC2
L1 L2 L3
35B
36B
37B
ST1
(MB)
VFD
FM2
U V W
L3
78
T4
T5
15
AR2
FM1
T2
T3
AO3(+)
(MB)
ATB
T1B
T2B
T3B
COMP
T1
79
BMR1-1A
47
T6
26A
B1
80
B2
B3
81
B4
68
69
70
L2
COMP
27A
BMC
L1F
L2F
L3F
CC2
35A
36A
37A
L1
103
104
105
100
101
102
FMC1
CC1
T1A
T2A
T3A
UVM CONNECTION
AO3(-)
(MB)
L1B
L2B
L3B
L1A
L2A
L3A
L1E
L2E
L3E
CB1
B5
B6
L2 L3
L1
1 UVM-1 8
B7
BM
UVM
CONTROL CONNECTIONS
TO ATB 1
TO ATB 1A
TO HVTB
L1
UVM-1
TO HVTB
L3
ES
F3 (5A)
ATB
1
F1 (3.5A)
1A
1B
TRANS1
(500VA)
3
5
460V
230V
4
6
TO ATB
TO ATB
F4 (5A)
F2 (3.5A)
ATB
2
F5 (2A)
F6 (2A)
TRANS2
(30VA)
14
16
230V
SW1
56
OFF
GEN RUN
AR8-1B
ATB
15
ATB
17
24V
GND
FAN
40
(GEN SET START)
41
42
TO MB
T6
8C
8NO
TO VFD
T5
47
AR2
48
AR3
51
AR4
A14
CR1
TO MB
SW2
VFD READY/FAULT
RELAY
VENT
AR3-1A
COOL
CR1-1A
TO MB
43
AFS
A13
BMR1-2A
49
SW3
AR4-1A
LOW COOL
MED COOL
TDS
NC
50
NO AIR FLOW
RELAY
NO
HIGH COOL
CR1-2A
46
44
TO MB
45
TO MB
52
A20
AR5
LOW FUEL
RELAY
AR5-1A
BMC
17C
AR1
17O
TO MB
53
AR6
54
AR7
55
AR8
COMP1 TRIP
RELAY
AR6-1A
18C
TO MB
18O
AR7-1A
SW4
(RE-SET)
16
COMP2 TRIP
RELAY
TO ATB
TO ATB
230V ac
ATB
16
TRANS3
(75VA)
14
230V
24V
24V AC
PE
A1 (SSPS-1)
CB1A-1
22A
HPS1
10A
A2 (CB-1)
OLR1-1 11A
A3 (OL-1)
TK(FM1)
12A
AO4
78
A5 (FCB-1)
AO3
A6 (SSPS-2)
CB2A-1
22B
HPS2
10B
TO VFD
A4 (HPS-1)
T4
(0~10V)
79
T1
A7 (CB-2)
OLR2-1 11B
AO2
A8 (OL-2)
TK(FM2)
12B
A9 (HPS-2)
AO1
A10 (FCB-2)
A11 (FLW)
BMCA-1A
71
FROM SW2
72
FROM SW1
AR5-3A
43
(GEN RUN)
73
AR9-2A
74
AR2-2A
75
BMR2-1A
76
44
FROM SW3
45
ATB
15
1C
R1(DIG OUT)
1O
2C
R2(DIG OUT)
2O
CC1
3A
3C
R3(DIG OUT)
3O
4A
4C
R4(DIG OUT)
4O
3B
5C
R5(DIG OUT)
5O
6C
R6(DIG OUT)
6O
7C
R7(DIG OUT)
7O
8C
R8(DIG OUT)
8NO
COMP1 CONTACTOR
HGS1
COMP2 CONTACTOR
HGS2
4B
48
AR3
8NC
R9(DIG OUT)
9NO
R10(DIG OUT)
10NO
R11(DIG OUT)
11NO
R12(DIG OUT)
12NO
R13(DIG OUT)
13NO
R14(DIG OUT)
14NO
R15(DIG OUT)
15NO
R16(DIG OUT)
16NO
17C
R17(DIG OUT)
17NO
53
18C
R18(DIG OUT)
18NO
54
ATB
15
S1
(A5-SP1) +
SH
22A
24A
AO-MTR SPEED
(0~+10V)
B1
T1
SH
S2 (A8-SP2)
22B
TOUT=10C TIN=15C
COOLING 75%
ESC *
TAE
SH
SH
On/Off *
SET MENU *
D2 (A9-DP2)
24B
25B
ON
S1
O2 (A10-OP2)
DIP
SERIAL CABLE
1 2 3 4
COM1
SPT1
28A
29A
SH
DPT1
30A
31A
SH
GND
17
SPT2
28B
29B
DPT2
30B
31B
SH
SH
RH
23B
SH
FMC2
18B
FM2 CONTACTOR
AR6
(COMP1 TRIP)
AR7
(COMP2 TRIP)
COMP1
SUCTION PRESSURE TRANSDUCER
COMP1
DISCHARGE PRESSURE TRANSDUCER
ST1
(A1-ST1)
27A
BLOWER MOTOR
(VFD) RELAYS
BMR2
O1 (A7-OP1)
SH
26A
FM1 CONTACTOR
BMR1
82
T.OUT
25A
SH
TO VFD
D1 (A6-DP1)
ST2
23A
SH
FMC1
18A
COMP2
SUCTION PRESSURE TRANSDUCER
COMP2
DISCHARGE PRESSURE TRANSDUCER
PRESSURE SETTINGS
DESC.
COMP1
C.HTR1
L2
ES
ATB
COMP2
ATB
1A
C.HTR2
1B
LOW PRESSURE
L1
L2
L3
25
--
HIGH PRESSURE
400
--
HPS1 & 2
450 10
360 15
HGS
55
45
ATB
2
ES (gen set)
SW6
84
SW7
85
83A
83B
JU1 - CLOSED
JU2 - CLOSED
LT9
LT10
TU1 - CLOSED
TU2 - CLOSED
TL1 - OPEN
TL2 - OPEN
TD1 - CLOSED
TD2 - CLOSED
S1
TO ATB
24V ac
15
ON
OFF
OFF
OFF
17
LEGEND
SW5
(LAMP TEST)
57
AR9
AR10
AR1-1A
58
LT1
59
LT2
60
LT3
61
LT4
62
LT5
63
LT6
POWER ON
AR9-1A
AR3-2A
AR9-2A
AR4-2A
NO AIR FLOW
AR9-3A
AR5-2A
LOW FUEL
AR9-4A
AR6-2A
COMP1 TRIP
AR10-1A
AR7-2A
HVTB
JP
L1/L2/L3
LPS
LUG
MB
OLR
SW
TDS
TK
TRANS
UVM
VFD
AUXILIARY RELAY
AUXILIARY TERMINAL BLOCK
BLOWER (SUPPLY) FAN MOTOR
VFD POWER CONTACTOR (BM)
BMC AUXILIARY CONTACT
CIRCUIT BREAKER
COMPRESSOR CONTACTOR
CC AUXILIARY CONTACT
CRANKCASE HEATER
COMPRESSOR
CONTROL RELAY
EMERGENCY STOP PUSH BUTTON SWITCH
FUSE
FAN MOTOR (CONDENSER)
FAN MOTOR CONTACTOR
HOT GAS BY-PASS SOLENOID
HIGH PRESSURE SWITCH
HIGH VOLTAGE TERMINAL BLOCK
JUMPER
POWER LINES
LOW PRESSURE SWITCH
LUG GROUND
MICROSMART CONTROL BOARD
OVER LOAD RELAY
SWITCH
TIME DELAY SWITCH
MOTOR (PROTECTION) THERMAL CONTACT
TRANSFORMER
VOLTAGE MONITOR RELAY
VARIABLE FREQUENCY DRIVE
SPLICE-CLOSED END
DISCONNECT TAB-1/4"
COMP2 TRIP
AR10-2A
TERMINAL BLOCK OR
TERMINATION POINT
INDICATOR LAMPS
JUNCTION OF WIRES
AR10-3A
CROSSING OF WIRES
NO CONNECTION
GEN SET
FAULT CONTACT
(in gen set control panel)
+12V dc
(gen set battery)
AR
ATB
BM
BMC
BMCA
CB
CC
CCA
C.HTR
COMP/C
CR
ES
F
FM
FMC
HGS
HPS
64
65
EARTHING / GROUND
AR1-2B
66
LT7
NOTES
1. ANY WIRE REPLACEMENT, SHOULD BE OF THE 90C TYPE
OR ITS EQUIVALENT.
2. USE COPPER CONDUCTORS ONLY.
3. COMPRESSORS ARE PROVIDED WITH INTERNAL LINE BREAK
THERMAL PROTECTION.
4. REMOVE GEN SET 12V BATTERY WIRE CONNECTION WHEN
UNIT IS NOT IN USE.
TO ATB
1
230V ac
2
AR5-4A
AR10-4A
67
LT8
LOW FUEL
(BEACON LIGHT)
18