Ningbo YP 970
Ningbo YP 970
Ningbo YP 970
NINGBO DAVID
OPERATOR
OPERATORS MANUAL
970
YP-970
YPINFANT INCUBATOR
Please take well care of it.
SPECIAL STATEMENT
STATEMENT:: All of the content in the manual is checked carefully, if there is
any error or content of printing misunderstanding, our company
retains finally explanation of this card-usage.
NOTE: The product
products appearances maybe differ from the one in this manual, but it dose
not affect the capability of product. Please understand if it brings you troubles.
NO.
35,
JINXING
ROAD,
BINHAI
INDUSTRIAL
PARK,
XIANGSHAN
ECONOMIC
FAX: 0086-574-65962111
FAX: 0086-574-87801111
sales@nbdavid.com
WEBSITE: http://www.nbdavid.com
EUROPEAN REPRESENTATIVE: SHANGHAI INTERNATIONAL HOLDING CORP. GMBH (EUROPE)
ADD: EIFFESTRASSE 80, 20537 HAMBURG, GERMANY
TEL: 0049-40-2513175
FAX: 0049-40-255726
EDITION/REVISION C/0
Emission test
Compliance
RF emissions
CISPR 11
Group 1
for
its
internal
function.
Therefore,
its
RF
RF emission
CISPR 11
Harmonic emissions
IEC 61000-3-2
Class B
Class A
Voltage fluctuations/
flicker emissions
Complies
IEC 61000-3-3
Page 1 of 4
Immunity test
Compliance level
Electromagnetic environment
- guidance
Electrostatic
6 kV contact
6 kV contact
discharge (ESD)
8 kV air
8 kV air
IEC 61000-4-2
Electrical fast
transient/burst
lines
supply lines
IEC 61000-4-4
hospital environment.
Surge
1 kV differential mode
1 kV differential
IEC 61000-4-5
2 kV common mode
mode
2 kV common mode
hospital environment.
<5% UT
<5% UT
interruptions and
voltage variations on
40% UT
40% UT
requires
continued
operation
IEC 61000-4-11
during
for 5 cycles
for 5 cycles
interruptions, it is recommended
power
mains
NOTE
70% UT
70% UT
be
for 25 cycles
for 25 cycles
a battery.
<5% UT
<5% UT
for 5 sec
for 5 sec
Page 2 of 4
powered
from
an
Immunity test
Compliance
level
Conducted RF
3Vrms
IEC 61000-4-6
3 Vrms
3.5
d = P
V1
10 Vrms
10 Vrms
Radiated RF
10 V/m
IEC 61000-4-3
10 V/m
80 MHz to 800 MHz
NOTE 1
At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
a
The ISM(industrial, scientific and medical) bands between 150kHz and 80MHz are 6.765MHz to 6.795MHz; 13.553
MHz to 14.567 MHz; 26.957 MHz to 27.283 MHz; and 40.66 MHz to 40.70 MHz.
b
The compliance levels in the ISM frequency bands between 150kHz and 80MHz and in the frequency range 80 MHz
to 2.5GHz are intended to decrease the likelihood that mobile/portable communications equipment could cause
interference if it is inadvertently brought into patient areas. For this reason, an additional factor of 10/3 is used in
calculating the recommended separation distance for transmitters in these frequency ranges.
c
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey
should be considered. If the measured field strength in the location in which the YP-970 Infant Incubator is used
exceeds the applicable RF compliance level above, the YP-970 Infant Incubator should be observed to verify normal
operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or
relocating the YP-970 Infant Incubator.
d
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m.
Page 3 of 4
(m)
maximum
80 MHz to 800
output power
in ISM bands
MHz
of transmitter
(W)
3.5
d = P
V1
0.01
0.1167
0.12
0.12
0.23
0.1
0.3689
0.3795
0.3795
0.7273
1.1667
1.2
1.2
2.3
10
3.6893
3.7947
3.7947
7.2732
100
11.6667
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2
The ISM(industrial, scientific and medical) bands between 150kHz and 80MHz are 6.765MHz to
6.795MHz; 13.553 MHz to 14.567 MHz; 26.957 MHz to 27.283 MHz; and 40.66 MHz to 40.70 MHz.
NoTE 3 An additional factor of 10/3 is used in calculating the recommended separation distance for transmitters in
the ISM frequency bands between 150kHz and 80 MHz and in the frequency range 80 MHz to 2.5 GHz to decrease
the likelihood that mobile/portable communications equipment could couse interference if it is inadvertently brought
into patient areas.
NOTE 4 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
Page 4 of 4
WARRANTY
The product being described in this manual is warranted against defects in materials or
workmanship for one year from the date of shipment, with the following exceptions.
1. All consumable and disposable products are guaranteed to be free from defects upon
shipment only.
2. Calibrations are considered normal maintenance and are not included in the 1-year
warranty.
During the warranty period any defective parts other than those listed above will be replaced
at no charge to the customer.
This warranty is rendered void and our company cannot be held liable for conditions resultant
therefrom if:
1. Damage to the unit is incurred as a result of mishandling.
2. The customer fails to maintain the unit in a proper manner.
3. The customer uses any parts, accessories, or fittings not specified or sold by our company.
4. Sale or service is performed by the non-certified service/dealer agency.
This warranty is in lieu of all other warranties, expressed or implied, and our company shall in
no event be liable for incidental or consequential damages including loss of use, property damage,
or personal injury resulting from breach of warranty.
The Accreditation Manual for Hospitals requires each piece of equipment to be tested prior to
initial use and at least annually thereafter. To comply with this standard, we recommend that you
participate in our accreditation Testing compliance Program during the warranty period. This
service can be performed through our company and authorized dealers.
SERVICE
For optimal performance, product service should be performed only by authorized and
qualified service personnel. Please contact the local agency or the After-Sales of our company to
get more technical information about maintenance.
I4
OPERATING PRECAUTIONS
1. INFANT INCUBATOR (incubator) belongs to high risk medical device which can endanger
infant's life. Therefore please use the device only in neonate nursing room, children nursing
room, pediatric intensive care unit or similar sickroom in hospital. Operator for the device should
be special trained and operate the device under the instruction of medical practitioner.
2. The operator must keep observing the patient's condition while the device is working. Supervise
and record baby's temperature regularly to check whether the temperature of the patient is over
high/low or any other unusual conditions happen.
3. Please stop using the device when it failure or disfunction. Turn off the power and tansfer the
patient out from the device, then inform our company or our authorized agency for service. DO
NOT ask for service from person who's not been authorized by our company.
4. Direct radiation from sunlight or other infrared source could cause overheating of the infant
without activating the Over Temperature Alarm. DO NOT leave the INCUBATOR in direct
sunlight or near other sources of radiant heat.
5. DO NOT leave the INCUBATOR in the presence of flammable anaesthetic gases or other
flammable materials, such as some types of cleaning fluids.
6. DO NOT leave the INCUBATOR in the presence of strong electromagnetic field.
7. Devices which are easily interfered by magnetic field should not be used near the INCUBATOR
because they may interfered by the INCUBATOR.
8. The incubator does not equip the air cleaner, to make sure the good air quality inside hood, the
incubator should be used in the environment with clean air.
9. Please DO NOT use the INCUBATOR under working environment not stipulated in table 1.1, or
else, it may cause the failure or the INCUBATOR can not reach the requirements.
10. To prevent harm to the infant, the hood should not be raised while leads are connected to the
infant or if the mattress tilted.
11. There should be no need to raise the hood at any time while the infant is cared for in the
incubator. All necessary access to the infant can be achieved by means of the Access Panel and
Access Doors.
12. When the Access Panel is open, the temperature from the air temperature indicator maybe not
the real temperature inside incubator. Therefore, do not leave the Access Panel open much
longer.
13. All access panels latch should be firm plugged, in case accidental open.
14. For infant safety, DO NOT leave the infant unattended when the Access Panel is open.
15. Other accessories within the incubator which can alter the air flow pattern may affect
temperature uniformity and temperature variability.
16. Turning on Phototherapy unit may affect hood wall temperature, incubator air temperature and
infant skin temperature, at this time, we suggest the incubator should be worked in the baby
mode, otherwise the set air temperature of the thermotherapy devices has to be reduced
according to body temperature measurement.
ii
I4
17. Patient safety and incubator performance may be compromised if air flow passages are not
kept clear of obstructions (blankets, stuffed animals, etc.) during clinical usage.
18. Do not place surgical covers or blankets over the infant and warm air curtain or side vents
simultaneously. This may cause heat induced injury and burns.
19. Removing the incubator should be finished at least by two persons with great strength. Please
pull out all power cords before moving.
20. To prevent the harm on patient for accidental moving, please lock the casters during usage.
21. To prevent accidental disconnection, secure all patient leads, infusion lines and ventilator
tubing to the mattress with sufficient excess length to allow for the full range of mattress
height adjustment.
22. To avoid water over flow from water chamber, and keeping the most stable position of infant
incubator, before moving all of accessories should be fixed to the right position and let out all
of the water.
23. Do not switch on for longer time than essential, when the machine not connect to the power
supply, otherwise, power supply failure alarm will be actively and the internal battery current
waste.
24. When using X-Ray tray via incubator hood, the shadow of hood will reflect on the X-ray
negative. That maybe influence the doctors diagnose.
25. Do not place any article higher than incubators caster under its VHA cabinet which may affect
the stabilization of VHA cabinet.
26. When operating the VHA cabinet, support the incubator with one hand on to prevent it from
unbalance.
27. When replacing the fuse, you must cut off the power supply and replace it according to the
stipulated specification.
28. The device must be fully cleaned and sterilized for the first time for initial use, after nursing for
one baby, after used it for one week or there's dirt in the incubator. Cleaning and sterilizing
methods please refer to Section 5.
29. Please use the neutral deterge/ disinfectant registered by nation. Other disinfectant (like
alcohol) will destroy some parts of the incubator. Please follow the instruction for detergent
usage.
30. The customer uses any parts, accessories, or fittings only specified or sold by our company, or
else, it will reduce the safety of device.
31. Damages will be easily caused if using the incubator after it reached its lifetime. Previous
capability guideline and requirement cannot be reached as well.
32. The device, accessories and the packaging have to be disposed of waste correctly at the end
of the usage. Please follow Local Ordinances or Regulations for disposal.
I4
iii
ELECTRICAL PRECAUTIONS
1. To ensure grounding reliability, connect the ac power cord only to a properly grounded 3-wire
hospital grade or hospital use outlet. Do not use extension cords. If any doubt exists as to the
grounding connection, do not operate the equipment.
2. An electric shock hazard exists within the Controller and VHA base assembly when the cover is
removed. Servicing should be performed only by qualified personnel with appropriate service
documentation.
3. To prevent equipment damage or accidental power disconnection, Do NOT connect an
Incubator power cord directly to an ac wall socket when the Incubator is mounted on a VHA
stand. Always provide power to the Incubator using the power cord coming directly form the
VHA stand.
4. Make sure the building power source is compatible with the electrical specifications shown on
the rear center column of the VHA stand or on the Incubator.
5. This device adopts mains plug or appliance coupler as isolation form the supply mains when the
Incubator is mounted on a mobile stand, for safety, and please pull off the power cord when
stopping using the device or repair it.
6. Improbably using of the assistant device will cause the decrease of our devices safety. The
safety of auxiliary devices shall comply with the general requirements for safety according to
IEC601-1, and have acquired the certificate by relative institution.
HUMIDITY PRECAUTIONS
1. The incubator is with the humidity controller, it can increase the Humidity of incubator according
to the clinical demands.
2. Higher relative humidity will, at any given time, decrease an infants evaporative water loss and
may cause an increase in infant temperature. Monitor the infants temperature as required.
3. Use only distilled water to fill or refill the Reservoir. Tap water may contain organisms that may
flourish in the heated water of the humidifier.
4. Make sure all hood access door gaskets and tubing ports are properly installed. Any open gaps
in the incubator hood will reduce the incubators internal relative humidity.
5. Fill the humidity chamber to the bottom of the MAXIUM LIMIT line. DO NOT OVERFILL. Or else
water spillage may result.
6. Following the doctors advice when setting the relative humidity.
iv
I4
OXYGEN PRECAUTIONS
1. This incubator is with oxygen control system, please use iatric oxygen when feeding oxygen.
2. Abusing of supplemental oxygen may result in serious aftereffects which include blindness,
brain damage, even death. Therefore, keeping to the main doctor's direction strictly and
monitoring the oxygen supplement condition for the patient in a regularly time.
3. If it is necessary to administer Oxygen in an emergency, notify the attending physician
immediately.
4. When supplementing the oxygen, calibrated oxygen analyzer must be turned on for monitoring
the oxygen concentration.
5. Oxygen feeding may increase the noise level inside the hood.
6. As Oxygen use increases the danger of fire. To ensure the device safety, make all flammable
material far away from incubator, and auxiliary equipment producing sparks should not be
placed near incubator.
7. When the oil, grease, other fat substance and the compressed oxygen meet, it will self-ignite
seriously, therefore, try to avoid the oxygen pressure reducing valve/adjustment valve, valve for
oxygen cylinder, pipe, connector containing these substance.
8. Do not use combustible material like aether, alcohol etc. because once even a little aether,
alcohol, or other combustible material mixed with oxygen in the incubator, itll cause fire.
9. When modulating the oxygen flux every time, please leave 30min. at least for the incubator
regaining the new oxygen concentration.
10. Theres a pressurize device filling with potassium hydroxide electrolyte installed inside the
oxygen sensor. If the sensor leaks, please stop using and chuck it. If the leaking electrolyte
touches skin or clothes, please wash with clean water immediately. If the leaking electrolyte
touches eyes, please wash eyes with clean water for 15 min. and keep them open, notify the
doctor immediately.
11. Seasonal check the gas and the oxygen transporting parts to see if they are eroded or broken.
12. Seasonal check the battery of oxygen sensor to if they are leaking or aging. Replace them if it
is necessary.
13. A little flammable material left inside of hood will meet oxygen and cause fire, such as aether or
alcohol.
14. Please refer to the relevant user's manual when the auxiliary oxygen device is used together
with the incubator.
I4
WEIGHING PRECAUTIONS
1. The electrical scale installed in the bassinet must work after 30 minutes warm-up in the
incubator, that is to say the electrical scale cant work until being put in the incubator which is
set the using temperature and begins working for at least 30min. Or else, the number read on
the scale will surpass the regulated value.
2. Please keep the patient aclinic and in the middle of the bassinet while weighing.
3. The maximum weighing weight of Infant scale is 8 kg, please dont over loading, or else the
scale will be damaged.
4. Lay the bassinet with infant scale gently when loading or unloading, dont press surface of the
bassinet to avoid damage the weight sensor inside the bassinet.
5. The displayed weighing value is just for reference.
3 . Inspect the fuse to verify compliance with rated current and breaking characteristics.
4 . Verify that the device functions properly as described in the instructions for use.
5 . Test the protection earth resistance according IEC 60601-1:1988 + A1:1991 + A2:1995:
Limit 0.1.
6 . Test the earth leakage current according IEC 60601-1:1988 + A1:1991 + A2:1995: Limit:
applied part according IEC 60601-1:1988 + A1:1991 + A2:1995: Limit: for a.c.:500A (BF), for d.c.:
50A (BF).
10 . According to the test methods of IEC 60601-1:1988 + A1:1991 + A2:1995, the patient
leakage current (net voltage should be added on the applied part) of the testing device must less
than 5000A.
11 . Test the patient auxiliary leakage current according IEC 60601-1:1988 + A1:1991+
A2:1995: Limit: NC for a.c.: 100A (BF), for d.c.: 10A (BF).SFC 500A (BF), for d.c.: 50A (BF).
vi
I4
NOTE
NOTE,, IMPORTANT, CAUTION AND WARNING
NOTE: A note is inserted in text to point out procedures or conditions, which may otherwise be
misinterpreted or overlooked. A note may also be used to clarify apparently contradictory or
confusing situations.
IMPORTANT
IMPORTANT:: Similar to a Note but be used where greater emphasis is required.
CAUTION: A caution is inserted in text to call attention of a procedure which, It not followed
exactly, can lead to damage or destruction of the equipment.
WARNING: A warning is inserted in text to call attention to dangerous or hazardous conditions
inherent to the operation, cleaning, and maintenance of the equipment which may result in
personal Injury or death of the operator or patient.
I4
vii
SYMBOLS
CLASS I
Class I Equipment
Main power on
/50
Hz AC Power 220-230V, 50Hz
220-230V~
220-230V~/50
/50Hz
Weight Limit
RS
RS--232
O2
ON/OFF
>37
>37
CAL.
SN
RS-232 Connector
LOW
HIGH
Indicator ON/OFF
SEL
Keypad Key
37 setting key
ZERO
Calibration key
CE Marking
Serial Number
Date Of Manufacture
Manufacturer
/50Hz MAX:1.6A
220-230V~
220-230V~/50Hz
viii
I4
CONTENTS
PAGE
SECTION
1. GENERAL INFORMATION
INFORMATION1-1
1.1 Introduction1-1
1.2 Intended use1-1
1.3 Composition of products1-1
1.4 Description1-1
1.5 Specifications1-3
2. INSTALLATION
INSTALLATION2-1
2.1 General2-1
2.2 Unpacking2-1
2.3 Installation2-1
DESCRIPTION3-1
3. FUNCTION DESCRIPTION
3.1 General function description3-1
3.2 Temperature control principle3-1
3.3 Data communication connector3-2
3.4 Alarming and system indication information3-3
OPERATION4-1
4. OPERATION
4.1 General4-1
4.2 Power supply connection and switch control4-1
4.3 Controller, indicators4-2
4.4 Operation checkout procedure4-5
4.5 General operation procedure4-14
5. CLEANING AND MAINTENANCE
MAINTENANCE5-1
5.1 General5-1
5.2 Cleaning5-1
5.3 Sterilization5-10
5.4 Maintenance5-10
5.5 Trouble shooting5-10
SYSTEM6-1
6. OXYGEN CONCENTRATION CONTROL SYSTEM
6.1 General6-1
6.2 Installation of oxygen sensor6-1
I4
ix
I4
SECTION 1
GENERAL INFORMATION
INTRODUCTION
1.1
1.1INTRODUCTION
This manual provides instructions for installation, debugging, operation, cleaning and
maintenance of Infant Incubator (incubator). We are not responsible for the malfunction which is
caused due to not following the instruction on our manual.
The operator should read and understand of the content of this manual.
This manual should be put together with the device so as to the client to check at any
moment.
VHA cabinit and weighing system are optional accessories. Besides, for air circulation fan
motor, user can choose either AC motor or DC motor. Disposable skin temperature sensor is also
provided as option. You can ignore the relative contents if you havent buy them. Neonate jaundice
phototherapy is optional assessory, if you buy it with the incubator, please refer to the operation
manual of Neonate jaundice phototherapy to see the relative operation.
E
1.2 INTENDED US
USE
The Infant Incubator is intended to provide a controlled thermal environment and isolation
from ambient air for premature and neonatal infants. The infant incubator is not intended for the
transport of infants.
3 COMPOSITION OF PRODUCTS
1.
1.3
The infant incubator consists of four components: the double wall hood, the base, the mobile
cabinet, and the controller. The sponge based mattress positions centrally within the confines of
the hood.
4 DESCRIPTION
1.
1.4
The following diagram shows the main parts of the Infant Incubator.
Neonate Bilirubin Phototherapy Equipment
I.V. Pole
Baby compartment
Shelf
Controller
Base
Mobile Cabinet
1-1
I4
DESCRIPTION OF PART
EXPLANATION
V. pole
I.
I.V
A kind of bearing part, which is used for hanging the infusion bottle.
Max. Load: 2Kg
Controller
The core part with two kinds of temperature control modes: air
mode, baby mode, moreover, it also have the function of weighing,
humidity control and oxygen concentration controling system which
are used for autocontrol the heat output and the huminidy and
oxygen concentration in the incubator. The detail operation to
temperature please refer to the section 4, to oxygen concentration
please refer to the section 6, to huminidy please refer to the section
7, to weighing please refers to the section 8.
Shelf
A kind of bearing part, which is used for putting some small objects.
Max. Load: 3.5Kg
Baby compartment
It is used for place the infant inside, including the Acrylic hood,
bassinet, and so on. The bassinet can be tilted at the request of
clinical needs. The baby scale is optional part, and the Max. Load
of bassinet is 10 Kg.
Max load of bassinet with weighting system is 8Kg.
Size of mattress: 630mm 355mm
Base
Mobile Cabinet
Neonate bilirubin
phototherapy
equipment
1.5 SPECIFICATIONS
Specifications for the Infant Incubator are provided in table 1.1.
Power Requirements
equirements
AC220V-230V/50Hz, 1000VA
Temperature Variation*
Variation*
0.5
Temperature Uniformity* (level mattress
mattress))
0.8
Temperature Uniformity* (Tilt mattress)
1.0
Deviation between the indicated air temperature and the real temperature
temperature
0.8
See table 3.1) Power failure alarm
ALARM(
ALARM(S
Fan motor alarm
Sensor failure alarm
High deviation alarm
Low deviation alarm
Over temperature alarm
The sensor box position alarm
Low Water alarm
Tank position alarm
System alarm
1-3
I4
continued
.......
Reservoir
Reservoirs cubage
cubage
.......
.......
1600ml
..
..
Control range
range
..
0%90%adjustable in 1% each time
ENVI TEM. 20
40
ENVI humidity 10%
90%
10%RH
Accuracy of humidity display
display
2040
40ENVI
10%90%
90%
NOTE: In the surrounding of high humidity, it may not control the humidity to a relatively low
level.
OXYGEN CONTROLLING
0%99%
Weight range
range
1008000g
...
Operating Range
Range
...
...+20+30
..
Storage Range
Range
..
..
-20+55
ENVIRONMENT HUMIDITY
Operating Range
Range
.. 30%75%RH
Storage Range
Range
.. 93%RH
ATMOSPHERIC PRESSUR
500hPa1060hPa
..
Ambient air movement rate
rate
..
..
..<0.3m/s
1-4
I4
continued
55dB(A)
[Ambient noise: 45dB(A)]
Noise inside hood
hood((equipped with DC motor
motor))Under the steady temperature condition 45dB(A)
under other conditions50dB(A)
[Ambient noise: 35dB(A)]
1-5
I4
SECTION 2
INSTALLATION
2.1 GENERAL
This section provides installing procedures about Infant Incubator.
2.2 UNPACKING
Generally, the Infant Incubator is usually packed to two cartons: main body and fixed cabinet
or Vertical Height Adjustment cabinet (VHA cabinet). When taking out the equipment from the
cartons, take care not to damage the spare parts of the Infant Incubator.
3 INSTALLATION
2.
2.3
At least two professionals are required to do the installation of the Infant Incubator with
spanners.
1. Install the main body onto the fixed cabinet or Vertical Height Adjustment cabinet
A. The installation of main body onto the fixed cabinet
a. As figure 2.1 indicates, put on the spring washer, flat washer on the casters, and then
connect with cabinet firmly. Note: The caster with brake must be installed in front of the cabinet.
FIGURE 2.1
b. As figure 2.2 indicates, lock the casters with brake, and put the guard rail and main body
on the cabinet, and then fix them with the lock mechanism on two sides of cabinet.
Guard Rail
Lock
II
Cabinet
2-1
I4
(Enlarged figure I)
wheel unlocked
wheel
locked
NOTE: See Enlarged figure I, lock the casters as the arrow 1 indicates, and unlock the
casters as the arrow 2 indicates.
See Enlarged figure II, hang on the lock, and close the lock spanner.
IMPORTANT: Be careful not to install the guard rail in wrong direction, or else, the
controller can not be taken out. The front access panel and the cabinet door
should be in the same direction.
therefore, fixing the guard
bolt
The guard rail ensure grounding through bolt
railon the cabinet with bolts.
FIGURE 2.2
B. Install the main body onto the Vertical Height Adjustment Stand
a. The method of installlation casters is same as part A.
b. The method of installlation main body, guard rail on the Vertical Height Adjustment cabinet
samw as part A.
c. After installation, insert the power cord on the right side of Vertical Height Adjustment
cabinet into the power socket in figure 4.2.
Guard Rail
Power cord
Lock
Cabinet
FIGURE 2.3
2-2
I4
WARNING
WARNING:: Firm the main body onto the fixed cabinet or Vertical Height Adjustment
cabinet with lock mechanism. If not, it will cause the main body to deviate
from the fixed cabinet or Vertical Height Adjustment cabinet when the cabinet
tilts, especially when the hood is open.
2. Install the NEONATE BILIRUBIN PHOTOTHERAPY EQUIPMENT, I.V.Pole and shelf
A. Install the NEONATE BILIRUBIN PHOTOTHERAPY EQUIPMENT
Please refer to the method of installation for incubator mounted PHOTOTHERAPY unit
XHZ-90 and XHZ-90L in the accompanying documents.
B. Install I.V. Pole and shelf
1 Install the I.V. Pole beside the incubator as figure 2.4 indicates, and then adjust the hook
Fixed seat
Step 1: loose the hexagon bolts on the fixed seat with spanner, insert the I.V. Pole to the bottom,
and fix the bolt to fasten the infusion rod.
Hook
for
infusion rod
Hexagon bolts
Turnbuckle
FIGURE 2.4
2 Install shelf
loose the hexagon bolts on the fixed seat as figure 2.5 indicatesinsert the fixed seat to the
infusion rod. Ensure the top of fixed seat is uniform with the position line on the infusion rod as
2-3
I4
A
Hexagon bolt
Fixed seat
When installing the shelf, the side with note label should face the front of incubator
incubator..
FIGURE 2.5
C. Install I.V. Pole and shelf without NEONATE BILIRUBIN PHOTOTHERAPY EQUIPMENT
equiped.
1 Install the I.V. Pole
Install the I.V. Pole beside the incubator as figure 2.6 indicates, and then adjust the I.V. Pole
to a proper height, fix it with the turnbuckle.
Hexagon bolt
Infusion rod
F ixed seat
Step 1: loose the hexagon bolts on the fixed seat with spanner, insert the I.V. Pole to the bottom,
and fix the bolt to fasten the infusion rod.
Turnbuckle
Hexagon bolt
Infusion rod
Step 2: Tight the hexagon bolts on the bottom
2 Install Shelf
loose the hexagon bolts on the fixed seat as figure 2.7 indicatesinsert the fixed seat to the
infusion rod. Ensure the top of fixed seat is uniform with the position limit mark on the infusion rod
2-4
I4
Enlarged figure A
Position limit mark
Shelf
A
Fixed seat
When installing the shelf, the side with note label should face the front of incubator
incubator..
FIGURE 2.7
3. Connect the sensor
Connect the sensor connector with sensor socket which is on the side of the incubators main
body as figure 2.8 directed. Then tighten the bolt in the connector.
Connection between the sensor connector and socket should in the right orientation
NOTE
NOTE
for these two parts have their own direction.
Fixed bolt
Sensor connector
FIGURE 2.8
4. Install oxygen sensor
Refer to the section 6 to see the detail.
5. Install weighing system
Refer to the section 8 to see the detail.
6. Insert the power cord
Insert the power cord into the socket of general power supply in figure 4.1 (for VHA cabinet);
Insert the power cord into the socket of general power supply in figure 4.2 (for fixed cabinet).
Check the INCUBATOR according to the instruction in section 4.4.
2-5
I4
SECTION 3
FUNCTIONAL DESCRIPTION
3.1 GENERAL FUNCTIONAL DESCRIPTION
Air Mode and Baby Mode
The Infant Incubator adopts temperature control system (Air
Mode),
humidity controlling system, oxygen concentration controlling system and weighing system (if it
is applicable).
Heat output control in Air Mode: it will control the heaters output automatically according
to the Air temperature sensor, see instruction in section 4.5.2.1;
Heat output control in Baby Mode: it will control the heaters output automatically
according to the Skin temperature sensor, see instruction in section 4.5.2.2.
Oxygen input control
controlAutocontrol the valve according to the oxygen concentration in the
incubator which detected by the oxygen concentration sensor. Please refer the section 6 to see
the details.
Reservoir humidifying output control Autocontrol the humidifier according to the
humidity in the incubator which detected by the humidity sensor. Please refer the section 7 to
see the details.
The set temperature, air temperature, skin temperature, oxygen concentration oxygen
setvalue, humidity value, humidity and weight (if it is applicable) can be indicated separately.
Except for the listed parts in section 1.4, the Infant Incubator also has 4pcs casters. (Two of
them with brakes)
3-1
I4
In addition, the air curtain outfited in the incubator will drive the air circle inside 1 flow
upwards and form a heat air circle flow at the access panel when the access panel of the hood is
open, thereby the temperature inside the hood will fall down.
FIGURE 3.1
1. If connect the auxiliary device on this connector, this auxiliary device should be
proved by the corresponding national standard, moreover, the whole system should
accord with the corresponding IEC601-1 or the adjusted relative standard.
2. Everyone should be responsible for the safety requirement to the whole system. If
there is any question, please consult our after sale service department or local agent.
3-2
I4
DESCRIPTION
If the mains power supply fails or no power supply, the alarm with
audible and visual will active.
Box Position
Alarm
If the sensor box wrongly placed, the Alarm
Alarm light will flash with
continuous audible sound. At the same time, Message Indicator
.
displays Box Position
Position
Air Sensor
Isolated Sensor
Airflow Sensor
Skin Sensor 1
In Baby Mode
Mode, If the skin sensor1 short-circuit, open-circuit or bad
Alarm
Alarm light will flash with continuous audible
connected, the Alarm
sound.
At the same time, Message Indicator displays Skin
Sensor 1.
Skin Sensor 1
Position
In Baby Mode
Mode, If thetemperature detected by skin sensor 1 always
Alarm
2 below the set temperature, the Alarm
Alarm light will flash with
continuous audible sound. At the same time, Message Indicator
.
displays Skin Sensor 1 Position
Position
Humidity Sensor
Oxygen Sensor 1
Oxygen Sensor 2
I4
DESCRIPTION
Air Error
Alarm
Alarm
After the air circulate inner the device stop for a while, the Alarm
light will flash with continuous audible sound. At the same time,
Message Indicator displays Airflow Error
.
Error
Motor Error
Fan Error
When the fan motor stops working or its running too slow, the
Alarm
Alarm
Alarm light will flash with continuous audible sound. At the same
. (When it is not
time, Message Indicator displays Motor Error
Error
applied for configuration of DC motor)
Alarm
When the fan inside the sensor box failure, the Alarm
Alarm light will
flash with continuous audible sound. At the same time, Message
.
Indicator displays Fan Error
Error
In Air Mode
Mode, If the air temperature is 3 higher than the set
Alarm
Alarm light will flash with continuous audible
temperature, the Alarm
.
sound. At the same time, Message Indicator displays High Temp
Temp
High Temp
In Baby Mode
Mode, If the temperature detected by skin sensor1 is
Alarm
1higher than the set temperature, the Alarm
Alarm light will flash with
continuous audible sound. At the same time, Message Indicator
.
displays High Temp
Temp
High Humidity
High Oxygen
Low Temp
In Baby Mode
Mode, If the temperature detected by skin sensor1 is
Alarm
1lower than the set temperature, the Alarm
Alarm light will flash with
continuous audible sound. At the same time, Message Indicator
.
displays Low Temp
Temp
Low Humidity
Low Oxygen
Ove
Overr Temp
In Air Mode
Mode, when the incubator temperature is less than 38(set
temperature 37) or less than 40 (set temperature 37),
Alarm
Alarm light will flash with continuous audible sound. At the
the Alarm
.
same time, Message Indicator displays Over Temp
Temp
In Baby Mode
Mode, when the incubator temperature is less than 40,
Alarm
the Alarm
Alarm light will flash with continuous audible sound. At the
.
same time, Message Indicator displays Over Temp
Temp
3-4
I4
DESCRIPTION
Low Water
Alarm
When the water in the water tank burned off, the Alarm
Alarm light will
flash with continuous audible sound. At the same time, Message
.
Indicator displays Low Water
Water
Tank Position
Alarm
When the water tank is not in the correct location, the Alarm
Alarm light
will flash with continuous audible sound. At the same time, Message
.
Indicator displays Tank Position
Position
System Alarm
System
When the internal system failure, the System
System light will flash with
continuous audible sound. And Message Indicator displays the
system alarm code. At the same time, please ask the qualified service
personnel to repair it.
NOTE: 1. If alarms active, the incubator will cut off the heater power supply
automatically. (Except low deviation alarm,oxygen concentration alarm and
humidity sensor alarm)
2. The class of system alarm is arranged according to the serial number of the
alarm code, the larger the serial number, the lower the class, when many failure
occur, the superior class will alarm first.
3-5
I4
SECTION 4
OPERATION
4.1 GENERAL
This section provides operation procedures for Infant Incubator.
FIGURE 4.1
Power switch
Auxiliary mains output socket
(To phototherapy)
See figure 4.3, for the infant incubator with VHA cabinet, the height adjustment foot button is
on the bottom of stand.
I4
4-1
TORS
4.3 CONTROLLERS, INDICA
INDICAT
1
4 5
6 7
10
11
12 13
14 15 16
17
O2
>37
>37
18 19 20 21 22
23
24
25 26
27 28 29 30
31 32
FIGURE 4.4
1. Oxygen concentration indicator key
Press this key to turn on or off the oxygen concentration indicator and oxygen concentration
control system.
2. Humidity indicator key
Press this key to turn on or off the humidity indicator and humidity control system.
3. Oxygen concentration indicator
Turnning the oxygen concentration indicator on to observe current oxygen concentration
valuedetected by oxygen concentration sensor, turnning it off, it indicates OF.
4. Humidity indicator
Display the current humidity value detected by the humidity sensor when it is on when
ternning it off, it display OF.
5. Humidifying indicator light
This light on indicates the humidifying system is on working.
6. Humidity set indicator
When the humidity control is turned on, it displays the humidity value.
7. Oxygen concentration set indicator
When the oxygen concentration control is turned on, it displays the oxygen concentration
value.
8. Set temperature indicator
Indicates the control value of air temperature in Air Mode
Mode; indicate the control value of baby
temperature in Baby Mode
ode.
9. Air temperature indicator
Indicate air temperature.
4-2
I4
I4
4-3
4-4
I4
Make sure that there is no crack or the sharp edge on the hood;
Make sure that the I.V.Pole and shelf are locked firmly;
Make sure that the tilt mechanism of bed can work properly ;
Make sure that the needed accessories and other devices are available;
4-5
Pull off the power cord of whole unit, the Power failure alarm should active, and the Power
Power
light will flash with continuous audible sound.
This operation is used for checking if the power failure is normal or not. Insert the power cord
again after finishing checking.
IMPORTANT: Make sure that the rechargeable battery is full before usage. If not full, it may
cause the power failure without the alarming indication. If full, and there is no
any indication after disconnecting the main power supply, please refer to the
qualified service personnel
personnel..
C. CHECK HEATER
Control the environment temperature at 21 ~ 26, and choose the Air Mode
Mode, and set the
temeprature at 33.0, and all heat power indicator are on, and heater wll output heat completely.
NOTE: When the incubator works under the set state, and continue the following operation
procedure.
D. CHECK THE ACCURACY OF TEMPERATURE CONTROL
Select the Air Mode
Mode, and set the air temperature at 36, after the air temperature enters into
the STEADY TEMPERATURE CONDITION
CONDITION, put the calibrated temperature measuring device on
the position above 10cm from the center of mattress to measure the air temperature, compared
with the indicated air temperature to check whether the deviation between them is within 0.8.
E. CHECK BABY MODE
Insert two skin temperature sensors into the socket of skin sensor1 and skin sensor2
sepratelythe arrow sign on the plug should aim to the opening on the sensor socket so that the
sensor is inserted correctly.
Skin temperature Sensor 1
Arrow
Opening
Sensor plug
Humidity sensor and air temperature sensor are located in the position A
Insert or pull out the skin sensor, you must hold the plug of skin sensor,
1.
1.Insert
pulling the leads is forbidden.
Please do not bend the connection of sensor.
2.
2.Please
OPERATORS MANUAL FOR INFANT INCUBATOR
4-6
I4
When the Air Mode works stablly, change it into the Baby Mode
Mode, set temperature at 37.
Keep the temperature detected by skin temperature sensor is 2 lower than the set temperature
while making the displayed air temperature 4 lower than the set skin temperature. The sensor
Alarm
failure alarm should be actived then.The Alarm
Alarm light will flash with continuous audible sound,
Skin Sensor 1 Position
and the Message indicator will show Skin
Position.
Alarm
Pull off the skin temperature sensor1, the sensor failure alarm should active. The A
larm
Skin Sensor
light will flash with continuous audible sound, and the Message indicator will show Skin
1.
F. CHECK PRECISION OF SKIN TEMPERATURE SENSOR
Put the skin temperature sensor with the mercury thermograph for the accuracy with 0.1C
into the water cup with the temperature as 30C5C. Make the probe of the skin temperature
sensor and the mercury ball as closely as possible and stir enough, then read the value of mercury
thermograph. Compare the value of the skin temperature sensor and the mercury thermograph,
and the deviation must be within 0.5C.
NOTE: Please check again if the accuracy of the skin temperature sensor exceeds the
permissibility deviation. Please let the professional maintenance man service
machine if the accuracy the skin temperature sensor exceeds the permissibility of
deviation again.
G. CHECK THE SENSOR BOX
Check the connection between the modular and its socket. Only when the interface of the
sensor box is correctly facing the interface of the sensor socket, they can be successfully
connected.
STATOR
Undraw the left stator of sensor box as the arrow indicates; under the condition of stator
undrawing, undraw the sensor box outwards, to check if the Sensor box slides in or out of the
Alarm
hood smoothly. When the modular falls off from the hood, The Alarm
Alarm light will flash with
Box Position
continuous audible sound, and the Message indicator will show Box
Position. After the modular
being put into the correct location and being fixed by stator, the alarm cancels automaticly as well
as the sensor connect indicating light off.
OPERATORS MANUAL FOR INFANT INCUBATOR
I4
4-7
WARNING
WARNING:: 1. All gaps in the sensor module must not be blocked.
2. Please pull out and plug in the sensor module correctly.
3. Sensor Module is an important part which supply Temperature Control to
Incubator, and must operate carefully.
H. CHECK FAN MOTOR ALARM
Block the inlet port and outlet port on the left and right side of main deck, after several minutes,
Alarm
larm light will flash with continuous audible sound, and the
the device gives alarms, the A
Airflow Error
Message indicator will show Airflow
Error.
When the incubator is equiped with AC motor, turn off the power supply of controller, and pull
off the power cord, and take out the controller.Reconnect the power cord, and hold the fan slightly,
Alarm
and turn on the switch of controller, and the fan motor alarm occurs, the Alarm
Alarm light will flash with
Motor Error
continuous audible sound, and the Message indicator will show Motor
Error.
WARNING: 1. If the temperature of heater inside controller is too high, you can
remove the conteoller or touch the heater after the unit is switched
off at least 45min to avoid the burn.
2starting after taking out the controller, please pay attention to the
power plug of oxygen concentration and humidity control system
to avoid electrical shock.
ERATURE ALARM
I. CHECK OVER-TEMP
OVER-TEMPERATURE
In Air Mode
Mode, enter into the working state, press Up
Up, Down and Silence/Reset key
key, there is
no indication on the Set Temperature indicator, and the heat power indicator is on in full, and the
controller has entered into the overtemp checkout state, and when the incubator temperature is
Alarm
less than 38.0 , the over-temperature alarm should active. The Alarm
Alarm light will flash with
Over Temp
37
continuous audible sound, and the Message indicator will show Over
Temp. In the state of 37
Override Mode
Mode, enter into the working state, press Up
Up, Down and Silence/Reset key
key, there is
no indication on the Set Temperature indicator, and the heat power indicator is on in full, and the
controller has entered into the overtemp checkout state, and when the incubator temperature is
Alarm
less than 40.0 , the over-temperature alarm should active. The Alarm
Alarm light will flash with
Over Temp
continuous audible sound, and the Message indicator will show Over
Temp.
Mode, press Up
Up, Down and Silence/Reset key
key, there is no indication on the Set
In Baby Mode
Temperature indicator, and the heat power indicator is on in full, and the controller has entered
into the overtemp checkout state, and when the incubator temperature is less than 40.0, the
Alarm
Alarm light will flash with continuous audible sound,
over-temperature alarm should active. The Alarm
Over Temp
and the Message indicator will show Over
Temp.
OPERATORS MANUAL FOR INFANT INCUBATOR
4-8
I4
4-9
Pressing Air Mode key while put the power of the controller on for more than 3 seconds until
the set interface appears. At that time, the Set Temperature indicator displays the set code and
Air Temperature indicator displays the corresponding value of each set item (the set code, set
item and set range please refer to the following table), the Skin Temperature indicator displays
P002 (which means the system has entered into the time seting interface). The operator could
select the set items through pressing the Baby Mode key or the Air Mode key and set the item
value through pressing Up Key or Down Key
Key. After seting one item, press Keypad Lock key to
save the seted value as well as press Silence/Reset key after seting all items for exit the seting
interface. If put off the power directly without pressing Keypad Lock key or Silence/Reset key
after seting, the time set will failure this time, system keeps the previous set value.
Table of time seting items
Set Code
Indicating Items
Set Range
001
19 ~20
002
00 ~99
003
month
01 ~12
004
day
01 ~31
005
week
006
hour
007
minute
00~59
008
second
00~59
Oritention lock
4-10
I4
LOCKED
UNLOCK
Rotate the panel Latches and make it stays opening. Press the latch seat to open the Access
Panel to the full open position (rotate downward). Close the Access Panel, the seat latch fastened
automatically and then rotate both latches until they are fully locked. Both latches and the seat
latch must be fully locked to avoid accidental opening of the panel.
C. CHECK IRIS ENTRY PORTS
Rotate the outer ring of each enrty Port, the port should be open and close as rotation is
continued through 360 degree.
D. CHECK THE LATCH AND GASKET OF ACCESS DOOR
Press on-off of each access door to open it automatically and check the seal of gaskets.
OPERATORS MANUAL FOR INFANT INCUBATOR
I4
4-11
frontaccess panel
Open the front access panel slightly press the front access panel towards the arrow1 and
move follow the arrow 2 directs, the inner wall of the front access door should be taken out easily.
After replace the inner wall, dont take it out.
F. CHECK MATTRESS TILT MECHANISM
4-12
I4
G. CHECK BASSINET
Open the Access Panel and slide it out to the fully extended position indicated by the arrow.
Lean on Mattress Tray to make sure it is properly supported to provide a firm infant platform.
Return the mattress and close Access Panel.
H. CHECK THE AIR INTAKE FILTER
Loosen the two thumb screws of the Air Intake Filter Cover and remove the cover and inspect
the filter, if dirty, it should be cleaned. Put the filter cover back.
WARNING: A dirty Air Intake filter may affect oxygen concentration and /or cause Carbon
Dioxide build-up. The filter must be checked on a routine basis and changed
at least every two months.
4-13
4.5.1 PREPARATION
4.5.1.1 Connect the power supply cord, sensor modular and skin temperature sensor1 correctly.
4.5.1.2 Pre-warm the incubator, put the patient on the bassinet after the air temperature reaches
the stable temperature to avoid the body temperature of the patient decreasing in the
non-prewarm incubator. The specific prewarm method is as follows:
Choose Air Mode
Mode, and set a proper control temperature, and make the device continue
working until the air temperature reaches the control value.
IMPORTANT: Please ask the physician to decide the set temperature.
4.5.2 OPERATION
4.5.2.1 AIR MODE
Air Mode means the controller will control the incubator temperature automatically to keep the
air temperature close to set temperature.
Incubator temperature is monitored the sensor probe and compared with the set air
temperature. The result of comparing is passed to the heater control circuit to control the heat for
keeping the set air temperature. The isolated temperature sensor as backup can control the
maximum incubator temperature. If the temperature is over high, and the heat protective device
will active, and the heater is cut off.
Press the Keypad Lcok key to select the Air Mode
Mode. Set the remperature at the wanted one.
The air temperature will keep within the range of 0.2 compared the set temperature.
When the incubator is working, if need changing the set temperature (decrease or increase),
press the Keypad Lock key to enlighten its indicating light, choose the Air Mode key to adjust the
37
set temperature through pressing Up and Down Key
Key. Set 37
37 Override Mode
Mode, you need to
37
press the Up key until the air temperature indicates 37, press 37
37 key , and the device will
enter into the temperature override mode, and 37 indicator is on, press Up key to set. After
chose the proper temperature, press Keypad Lock key to enter into the control mode, or without
pressing any key for 10s, and the controller will enter into the control mode automatically. Set
Temperature indicator displays the set temperature, and Air Temperature indicator displays the
air temperature, and Skin Temperature indicator displays the baby temperature tested by skin
temperature sensor1 (If the sensor is connected).
OPERATORS MANUAL FOR INFANT INCUBATOR
4-14
I4
which
I4
4-15
I4
4-17
SECTION 5
CLEANING AND MAINTENANCE
5.1 GENERAL
This section provides cleaning and maintenance instructions.
WARNING
1. Disconnect all the connections with oxygen feeding device before cleaning and
maintenance. Cleaning or maintenance in the environment full with oxygen will cause
fire or explosion.
2. The incubator with cabinet adopts the connector of power cord as the isolation
mains power supply, therefore, to make sure the safety, and pull off all powre cords
before cleaning.
5.2 CLEANING
This device must be cleaned and sterilized for the first time for initial use, or after used it for
one week.
5.2.1 DISASSEMBLY BEFORE CLEANING
A. Remove The Controller
Disconnect the Power Cord and Sensors from the side of the Incubator.Release the latch on
each side of the Controller as shown in Figure 5.1 to take out the controller.
Spanner
The controller can be taken out from the incubator, when the Spanner pull out to
>90
>90 direction.
WARNING: The Controller heater can be sufficiently hot to cause burns; avoid
removing the Controller or touching the heater until the unit has
switched..
been switched
FIGURE 5.1
I4
5-1
Limitation horn
Enlarged figure I
Inlet
FIGURE 5.2
C. Remove the air curtain
Raise the hood slowly as figure 5.3 directed, make the air curtain upright to the bassinet shelf
and move it out follow the direction of the arrow.
CAUTION: Before raising the hood, make sure that all installed accessories are all cut off.
FIGURE 5.3
5-2
I4
Fixed knob
Locked
Unlocked
FIGURE 5.4
I4
5-3
Step 1Move the limit hole in hood away from the position of fixed inner wall bolt
Step 2Remove the inner wall coping in the hood away from the fixed slot of inner wall, remove the
inner wall of the hood as well.
Step 3Press the inner wall on the access panel slightly as the arrow1 directed andremove the
inner wall out as arrow 2 directed.
FIGURE 5.5
5-4
I4
FIGURE 5.6
G. Remove Reservoir
Pull the Reservoir out slowly till it is locked as the figure 5.7 directs, then press it down slightly,
it can be pulled out.
Affusion meatus
Reservoir
FIGURE 5.7
CAUTION
CAUTION:: 1. Because the temperature of the water tank is high after the power of the
device is on as well as the heating groups are tighten then, so please take out
the water tank after it is totally cooling down to avoid damage to the heating
group.
2. The humidifying system is in the bottom of the reservoir. Don
ont put hands
into the reservoir to avoid being burned.
H. Remove the Access door gasket and Access door cuff, and Iris port sleeve from hood.
I. Remove the soft tubing from hood.
I4
5-5
Reek outlet
Detecting probe
Radiating cover
Water proof
I4
5-7
B. Install Air Intake Tube in the reverse steps as they are moved out. Installed Air Intake Tube
must comply to Figure 5.9.
WARNING: Air Intake Tube must be placed inside the Air Intake Tube Connector
and completely sealed.
FIGURE 5.9
C. Place Main Deck back.
Be sure the two thumb screws that hold the Mattress Tray are tightened.
D. Install the air curtain and the inner wall as figure 5.3 and 5.4 direct.
E. Install the controller as the figure 5.1 directs
Controller is the key unit of Incubator and must be installed carefully.
Insert Controller into Base Assembly. After the whole part is inserted into Base Assembly,
depress the snaps at both sides of Controller until they are parallel to the side then pull the
Controller outward. If the Controller is not loosened, it is already locked. (See Figure 5.10)
Correctinstallation state
CAUTION
CAUTION:: Power socket and plug of the humidity control are the power supply of the
incubator
incubators humidity control system. Do not force the controller in, or else the
power supply system will be dameged.
FIGURE 5.10
F. Rotating the iris entry sleeves, see figure 5.11.
Step 1: Install the elastic band over the inner ring of the port housing. Fold back and slip elastic
band over the outer ring of the port housing.
5-8
I4
Step 2: Rotate outer ring. If properly installed, the sleeve will open when reversing the rotation.
FIGURE 5.11
G. See figure 5.12, install the Access door gasket, and then isnatall the Access door cuff.
nner wall of hood
Inner
Outside of hood
FIGURE 5.12
H. Install the soft tubing in figure 5.13.
NOTE: The opening of soft tubing should face outward.
Opening
FIGURE 5.13
I. Install the Mattress cover with the mattress, and put the bassinet inside hood according to
the opposite order. (see Figure 5.2)
Place the bassinet as the label indicates on the infant bed.
I4
5-9
5.3 STERILIZATION
NOTE: Please do not steam autoclave.
Please sterilize under low temperature.
5.4 MAINTENANCE
Please check the condition of the build-in rechargeable battery before the first use of device
or in the alternation of device using.
A. Operate the unit for a period of 12 to 24 hours.
B. Trigger a power failure alarm by disconnecting the AC power cord.
C. The power failure alarm should activate and continue to alarm for at least 10 minutes.
D. Reconnect the unit to the AC line and recharge the battery.
If the power failure alarm cannot last more than 10 minutes, please replace the rechargeable
battery. For this battery, it should be replaced by authorized and qualified service personnel.
TROUBLESHOOTING TABLE
SYMPTOM
No indication, no alarm
POSSIBLE CAUSE
REMEDY
Power off
Alarm
The Alarm
Alarm light will flash,
and the Message indicator
Box Position
will show Box
Position
Alarm
The Alarm
Alarm light will flash,
and the Message indicator
Skin Sensor 1
will show Skin
5-10
I4
REMEDY
Ambient temperature
overhigh
High humidity
Ambient temperature
changes a lot
Alarm
The Alarm
Alarm light will flash, and
the Message indicator will
High Temp
show High
Temp
Ambient temperature
changes a lot
Alarm
The Alarm
Alarm light will flash, and
the Message indicator will
Oxygen Sensor 1
show Oxygen
Alarm
The Alarm
Alarm light will flash, and
the Message indicator will
Oxygen Sensor 2
show Oxygen
Alarm
Alarm light will flash, and
The Alarm
the Message indicator will
Over Temp
show Over
Temp
Alarm
The Alarm
Alarm light will flash, and
the Message indicator will
Low Temp
show Low
Temp
I4
POSSIBLE CAUSE
5-11
SECTION 6
OXYGEN CONCENTRATION CONTROL SYSTEM
6.1 GENERAL
This Section provides operation checkout procedure and operation instruction for the Oxygen
concentration control system.
Stopper
Pull out the stator on the left side of sensor box as the arrow indicates, and pull out the sensor
box, unscrew 2 Cross groove countersunk head bolts, and take out the sensor cover, and then
unscrew the stopper on it.
Oxygen Sensor
Sensor Cover
Pull the connecting wire of oxygen sensor out and connect the sensor with the double wire of
green and black, and please connect another oxygen sensor with the other double wire of yellow
and black. After correctly connecting them, screw the sensor cover board down with two M38
cross groove head bolt, then push the sensor box into the original place in the hood.
CAUTION: 1. Do not block any of the holes on the sensor box.
2. Please pull out and push in the sensor box in correct way.
3. Sensor box is the important part of controlling the temperature of the
incubator, please treat it carefully.
FIGURE 6.1
6-1
I4
3 FUNCTIONAL DESCRIPTION
6.
6.3
Oxygn Sensor 1
The incubator has the function of controling the oxygen concentration. The O
Oxygen Sensor 2 alarm, Oxygen
Oxygen Not Same
High Oxygen
alarm, the Oxygen
Same alarm, High
Oxygen alarm and
Low Oxygen
Oxygen alarm are all applying for the function of controlling. The details of alarm message,
Low
please see the table 3.1. If the above alarms are actived, press the Silence /Reset key to stop
alarming for about 110s. The power of the heater is not cut off, and the oxygen control system will
Low Oxygen
cut off the oxygen supplying automatically (Except for L
Oxygen alarm).
Connect the oxygen input tube which pass through the monitor with the oxygen input valve on
the left of the base (see the figure follows). Ensure they are sealed while connecting.
FIGURE 6.2
6-2
I4
Sensor box
Oxygen concentration
calibration device
FIGURE 6.3
6-3
I4
Alarm
concentration value deviates the basic value to -5%, the incubator alarming, the A
larm light will
Low Oxygen
Oxygen. When
flash with continuous audible sound, and the Message indicator will show Low
alarm actived, press Silence /Reset key to stop alarming, but the alarm indicator light continously
shines until the deviation is less than 5%.
6-4
I4
7 MAINT
EN
ANCE
6.
6.7
MAINTEN
ENANCE
A. Oxygen concentration sensor
When the oxygen concentration lifetime is in due, replace it even it is workable to ensure the
varacity of the detecting value. That is because:
The detecting accuracy of oxygen concentration sensor is influenced by the electrolyte inside
the sensor modular, and the electrolyte will be consumed along with the working time. So using the
over lifetime oxygen concentration sensor will result in wrong detected value.
B. Troubleshooting
Roubleshooting of the oxygen concentration sensor is presented in the following table. If the
fault cannot be localized from the table, the unit should be removed from service and servicing
should be referred to our company or authorized and qualified service personnel.
SYMPTOM
No indication of oxygen
concentration value
Alarm
The Alarm
Alarm light will
flash, and the Message
High
indicator will show High
Oxygen
Oxygen
Alarm
The Alarm
Alarm light will
flash, and the Message
Low
indicator will show Low
Oxygen
Oxygen
POSSIBLE CAUSE
Please calibrate
sensor again
the
oxygen
Please calibrate
sensor again
the
oxygen
6-5
I4
REMEDY
SECTION 7
HUMIDITY CONTROL SYSTEM
7.1 GENERAL
This section provides operation and checkout procedures and operation manual about
humidity control system.
7-2
I4
EN
ANCE
7.5 MAINT
MAINTEN
ENANCE
Troubleshooting of the humidity control system is presented in the following table. If the fault
cannot be localized from the table, the unit should be removed from service and servicing should
be referred to our company or authorized and qualified service personnel.
SYMPTOM
POSSIBLE CAUSE
Alarm
The Alarm
Alarm light will flash,
and the Message indicator
High Humidity
will show High
Humidity
Alarm
The Alarm
Alarm light will flash,
and the Message indicator
Low Humidity
will show Low
Humidity
Alarm
The Alarm
Alarm light will flash,
and the Message indicator
Low Water
will show Low
Water
Alarm
The Alarm
Alarm light will flash,
and the Message indicator
Tank Position
will show Tank
Position
7-3
I4
REMEDY
SECTION 8
WEIGHING SYSTEM
8.1 GENERAL
This section provides operation and checkout procedures and operation manual about
weighing system.
Weighing system is selectable.
8.2 INSTALLATION
Install the weighing system in the incubator as figure 8.1 directs.
Refer the F in section 4.4.3, Rotate the mattress mechanism to the lowest, then open the front
access panel, place the bassinet accessoried with electrical scale on the mattress mechanism and
make sure it can be push in and pull out as the arrow1 and arrow2 figure.
Arrow
Opening
Weight sensor
WARNING: 1. Insert or pull out the skin sensor, you must hold the plug of skin sensor,
pulling the leads is forbidden.
2. Please do not bend the connection of sensor.
Insert the sensor plug of the electrical scale into the socket on the sensor modular correctly
FIGURE 8.1
I4
8-1
8-2
I4
8.6 MAINTENANCE
Troubleshooting of the humidity control system is presented in the following table. If the fault
cannot be localized from the table, the unit should be removed from service and servicing should
be referred to our company or authorized and qualified service personnel.
SYMPTOM
No indication on
Weight indicator
POSSIBLE CAUSE
No power supply
Weight indicator
displaysErr
Weighing inaccurate
I4
REMEDY
8-3