DesignPlus User Guide - Eurocode RC - Ver2016
DesignPlus User Guide - Eurocode RC - Ver2016
midas Design+
User Guide
for Eurocode Modules
1. Design+ Interface 2
01 Design Interface +
SIMPLE MODE
Add new member
Simple and intuitive Add or import new members. Project/Simple/Check Mode
user interface Change the current working mode
Quick generation of
summary/detail design
result in Preview
window
Workbar
Member name change, Grouping,
Preview
Design or check results are
Report and Drawing Export Setup
displayed instantly.
Input
Input design data or force
(Automatically/Manually)
Report
Generate input data, summary,
and detail design result report
Detail
Summary
PROJECT MODE
Input List
Auto generation of drawing
MS word format report for Tab.
design/check results, Batch Switch the working window between member list, drawing, Quantity
report generation
Bill of materials
midas Link
Link with midas Gen
Multiple members can be selected and imported.
Report
Generate MS word and excel
format report.
Detail
Summary
Input List
Input List (Excel)
Message Window
Display various information, warning,
and error messages.
01 Design Interface +
Preview Option
Select Detail / Summary to check
the relevant report.
Workbar
Click a desired member from Tree
mode.
4
5
6 13
14
midas Design+ User Guide 4
Solution for Structural Member Design with Drawing & Report
03 midas Design+
Combined Wall
Contents
1 Import
2 Input Data
4 Member List
5 Drawing
6 Quantity
5
1. Execute Wall(Comb.)
module.
2. Click Project Mode. 1
3. Click midas Link.
Refer to the next page for
more details in the
limitation of midas Link.
4. Select midas Gen to be
linked with Design+.
5. Select desired wall
elements to be imported
from midas Gen. 2 3
6. Click [Connect] button.
7. Click [Import] button.
8. Check imported walls. 7
4
8
6
1. Wall ID must be different for each unit wall in midas Gen as shown in the figure below.
Importing combined walls with the same wall ID is not supported.
2. Walls must be located in a single story can be imported as combined wall in Design+.
3. Discontinuous combined walls cannot be designed in Design+.
Applicable (Importing Walls in One Story) Not Applicable (Discontinuity in Combined Wall)
1
Click [Wall Data] button to
see and modify rebar and
section information for entire
unit wall in a tabular format.
2. Data of vertical/ horizontal/
end rebar for the selected
unit wall.
3. Select Rebar Arrangement.
2
Divide equally by nearest
space: Rebar spacing is
adjusted to fit the wall
dimension using equal spacing
throughout the wall length.
Divide by exact space: 3
Specified rebar spacing is
applied from the End or Middle
of the unit wall.
4
4. Specify wall thickness and
concrete cover thickness.
In Preference, the user can
choose Concrete Cover
Depth as clear cover or 5
distance to the rebar center.
By default, concrete cover is
applied as clear cover
thickness.
5. Specify the wall coordinates
of start and end point and
vertical rebars for each unit
wall.
Note
1. Axial force: Summation of axial forces in unit walls (sign convention: + in compression)
2. Shear force: Summation of shear forces in unit walls. Shear forces of unit walls are re-
calculated in global X and Y-direction.
3. Bending moment is calculated as a summation of bending moments and eccentric moments
(axial force * eccentricity from a unit wall centroid to the combined wall centroid) of unit walls
about global X and Y-direction.
When local axis of a unit wall is not aligned in the global X and Y-direction, combined design
forces are calculated using the component of the forces in the global X and Y-direction.
2
Note
P-M Curve
3D P-M interaction is considered
to find the flexure resistance.
After performing wall checking,
Midas Design+ displays P-M 3
Curve in Theta angle described 1
below.
1
1.Select [Member List] tab.
Input and output data can
be checked and modified
for the all combined walls.
2. Click [Apply] button if
there is any change in the
design input data.
3.Click [All] and [Check]
button to verify the all wall
design results at once.
2 3
05 Drawing
Step
1
1.Select [Drawing] tab.
2. Select [Shear Wall
(Combined)] from the
drop-down box and click
[Create] button to
generate combined wall
drawings.
1
1.Select [Quantity] tab.
2. Select [Shear Wall
(Combined)] from the
drop-down box and click
[Create] button to
generate bill of materials.
3.Click [Export to Excel]
button to generate a MS
Excel file.
2 3
Note
EN/BS P5 P6 P7 P8 P9 P10 P11 P12 P13 P16 P20 P25 P32 P40
Weight (kg/m) 0.154 0.222 0.302 0.395 0.499 0.617 0.746 0.888 1.043 1.578 2.466 3.853 6.313 9.865
Diameter (mm) 5 6 7 8 9 10 11 12 13 16 20 25 32 40
Area (mm2) 19.6 28.27 38.5 50.27 63.6 78.54 95 113.1 132.7 201.06 314.16 490.87 804.25 1256.6
UNI P4 P5 P6 P8 P10 P12 P14 P16 P18 P20 P22 P24 P26 P30 P32 P36 P40
Weight (kg/m) 0.099 0.154 0.222 0.395 0.617 0.888 1.208 1.578 1.998 2.466 2.984 3.551 4.168 5.549 6.313 7.99 9.865
Diameter (mm) 4 5 6 8 10 12 14 16 18 20 22 24 26 30 32 36 40
Area (mm2) 13 20 28 50 79 113 154 201 254 314 380 452 531 707 804 1018 1257
04 midas Design+
General Column
Contents
2
1. Select a general column
from the tree menu.
2. Specify Member Name
and the additional task
3
scope after design. 1
3. Material Strength
Concrete: Characteristic
compressive of concrete
Main/Hoop Bar:
4
Characteristic yield strength
of major/ hoop
reinforcement
4. Specify unbraced length
and effective length factor.
Click button to use the
default values. 5
5. Select a splicing option
for the main rebars.
None: Longitudinal rebars 6
calculated without
considering splicing
50%: Longitudinal rebars
7
calculated considering
50%-splicing
100%: Longitudinal rebars
calculated considering
100%-splicing
6. Equivalent Dimension for
calculating eccentric
moment due to
imperfection as per clause
6.1(4),EN1992-1-1:2004
7. Options for considering Note
moment magnification Effective Length Scale Factor
due to imperfections and
2nd order effects as per
clause 5.8.3.1(1), EN1992-
1-1:2004.
Note
Tool-tip is displayed when
hovering the mouse over field K=1.0 K=0.5 K=0.7 K=2.0
with * mark.
1
1. Specify concrete cover
thickness. Concrete Cover
is applied as the distance
from the concrete face to 2
the rebar center.
2. Enter diameter and
spacing of hoop bars.
Check on Use User Input
option to apply different 3
rebar diameter and
spacing at the top and
bottom.
3. Enter the design forces.
4. Effective Creep Ratio for Note
the calculation of
When calculating shear resistance,
slenderness criterion (lim)
different value of axial force from
as per clause 5.8.3.1(1), the value for Axial Force and
EN1992-1-1: 2004 Moment verification can be defined.
5. Load Combinations Since shear resistance increase as
axial force increases, smaller axial
Toggle on : Design force may occur more critical case
forces can be directly 4 in shear force verification. Also
entered in the dialog box. shear resistance due to concrete is
Note
P-M Curve
3D P-M interaction is considered
to find the flexure resistance.
After performing column checking,
Midas Design+ displays P-M
Curve in Theta angle described
below.
1
1.Select [Member List] tab.
Input and output data can
be checked and modified
for the all general columns.
2. Click [Apply] button if
there is any change in the
design input data.
3.Click [All] and [Check]
button to verify the all
general column design
results at once.
2 3
05 Drawing
Step
1
1.Select [Drawing] tab.
2. Select [Column(General)]
from the drop-down box
and click [Create] button
to generate general
column drawings.
1
1.Select [Quantity] tab.
2. Select [Column(General)]
from the drop-down box
and click [Create] button
to generate bill of
materials.
3.Click [Export to Excel]
button to generate the
table in MS excel format.
Note
EN/BS P5 P6 P7 P8 P9 P10 P11 P12 P13 P16 P20 P25 P32 P40
Weight (kg/m) 0.154 0.222 0.302 0.395 0.499 0.617 0.746 0.888 1.043 1.578 2.466 3.853 6.313 9.865
Diameter (mm) 5 6 7 8 9 10 11 12 13 16 20 25 32 40
Area (mm2) 19.6 28.27 38.5 50.27 63.6 78.54 95 113.1 132.7 201.06 314.16 490.87 804.25 1256.6
UNI P4 P5 P6 P8 P10 P12 P14 P16 P18 P20 P22 P24 P26 P30 P32 P36 P40
Weight (kg/m) 0.099 0.154 0.222 0.395 0.617 0.888 1.208 1.578 1.998 2.466 2.984 3.551 4.168 5.549 6.313 7.99 9.865
Diameter (mm) 4 5 6 8 10 12 14 16 18 20 22 24 26 30 32 36 40
Area (mm2) 13 20 28 50 79 113 154 201 254 314 380 452 531 707 804 1018 1257
05 midas Design+
Strip Footing
Contents
1 Import
2 Input Data
4 Member List
5 Drawing
6 Quantity
1. Execute Footing(Strip)
module.
1
2. Click Project Mode.
Design member force can
be imported from midas
Gen when Project Mode
is selected.
3. Click midas Link.
Solid rectangle, T-Section,
and Inverted T-Section in
midas Gen can be
imported into Design+ to
perform strip footing
design.
In case of Inverted T-
Section, left and right
flange width (b1 and b2)
must be identical.
Midas Link supports beam 5
elements which are
assigned Point Spring
Support or Surface Spring
Support.
3
4. Select midas Gen to be
linked with Design+. 2
5. Select desired strip
footing elements to be
imported from midas Gen. 7
6. Click [Connect] button.
7. Click [Import] button.
8. Check imported footings.
4
Use Bottom Cover: Check on
the option to apply identical
concrete cover depth for top
and bottom.
5. Specify flexure design
1
method between singly
reinforced beam and double
reinforced beam design.
6. Specify soil bearing capacity
to be compared with soil
reaction.
5
7. Select a splicing option for
the main rebars.
None: Longitudinal rebars
calculated without considering
splicing
6
50%: Longitudinal rebars
calculated considering 50%-
splicing
7
100%: Longitudinal rebars
calculated considering 100%-
splicing
Note
Tool-tip is displayed when
hovering the mouse over field
with * mark.
1
2
1. Rebar Arrangement
Type-1 (All section): Select
when rebar data for i-end,
middle and j-end are
identical.
Type-2 (Both End &
Center): Select when rebar
data for i-end and j-end are
identical.
Type-3 (Each End &
Center): Select when rebar
data for i-end, middle and j-
end are not identical.
3
2. Change Section Data
3. Design Options
Column Loads
Load
Loading
Pressure
Bending
Moments
Reinforcement
2 3
06 Drawing
Step
1
1.Select [Drawing] tab.
2. Select [Footing(Strip)]
from the drop-down box
and click [Create] button
to generate strip footing
drawings.
Note
EN/BS P5 P6 P7 P8 P9 P10 P11 P12 P13 P16 P20 P25 P32 P40
Weight (kg/m) 0.154 0.222 0.302 0.395 0.499 0.617 0.746 0.888 1.043 1.578 2.466 3.853 6.313 9.865
Diameter (mm) 5 6 7 8 9 10 11 12 13 16 20 25 32 40
Area (mm2) 19.6 28.27 38.5 50.27 63.6 78.54 95 113.1 132.7 201.06 314.16 490.87 804.25 1256.6
UNI P4 P5 P6 P8 P10 P12 P14 P16 P18 P20 P22 P24 P26 P30 P32 P36 P40
Weight (kg/m) 0.099 0.154 0.222 0.395 0.617 0.888 1.208 1.578 1.998 2.466 2.984 3.551 4.168 5.549 6.313 7.99 9.865
Diameter (mm) 4 5 6 8 10 12 14 16 18 20 22 24 26 30 32 36 40
Area (mm2) 13 20 28 50 79 113 154 201 254 314 380 452 531 707 804 1018 1257
06 midas Design+
Isolated Footing
Contents
1 Import
2 Input Data
5 Member List
6 Drawing
7 Quantity
Link by Section : Import one component of critical reaction force among all members which have same section.
Link by Member : Import all components which were selected from midas Gen with each reaction forces respectively.
In this example, when Link by Section option is selected, only three components will be imported even if
six nodes are selected in midas Gen since there are only 3 different section properties.
When Link by Member option is checked, all six nodes will be imported separately.
2. The name and size for column from midas Gen to Design+
1C3 800X800(1237)
Node Number
Section Name
midas Gen midas Design+
Storey Name
Importing the member name format can be set by user at [Link Option] Dialog Box.
3. Critical reaction force among load combinations for ULS and SLS
2
1. Select the isolated footing
from the tree menu.
3
2. Specify Member Name and
the additional task scope
after design.
3. Material Strength 4
- Concrete: Characteristic
compressive strength of
concrete
- Main Bar: Characteristic yield
strength of reinforcement
4. Design Load
5. Surcharge Load
If Include Self-Weight
option is checked on, the
self-weight of column and
footing will be taken into
account for design load.
Y-Direction
6
6. Select the footing type as
Isolated(Mat) or Isolated(Pile)
and enter the footing depth
and clear concrete cover
depth.
7 X-Direction
7. Select the column shape and
enter the size of section. Ex 8
and Ey is for the eccentricity.
Note
Cx
Column
Cy
Ey
Center of
footing Ex
Note
Tool-tip is displayed when
hovering the mouse over field
with * mark.
10
10
An isolated mat footing transfers the loads from a single column to the supporting soil. The
size of the footing is determined by the allowable soil bearing pressure. The footing is
designed for flexure, punching or two-way shear and one-way shear. The depth of the footing
is generally governed by punching shear.
Where moments are applied to the pilecap the load combination should also be used to check the
piles can resist the overturning forces. A pilecap may be treated as a beam in bending, where the
critical bending moments for the design of the bottom reinforcement are located at the column
faces.
Both beam shear and punching shear should then be checked as shown in the figure below.
Stress zone
45
If the basic shear stress is exceeded, the designer should increase the depth of the base.
Alternatively, the amount of main reinforcement could be increased or, less desirably, shear links
could be provided.
MS Word Report from [Project Mode] PDF Report from [Simple Mode]
Allow the program to change the footing size while design process
In case the footing size is not satisfied with the design result, [Change Section by Design]
option can allow the program to find the footing size automatically.
06 Drawing
Step
1
1.Select [Drawing] tab.
2. Select [Footing] from the
drop-down box and click
[Create] button to
generate isolated footing
drawings.
2
CAD format of Drawings
Note
2
as concrete volume per unit
length. 3
Quantity of rebar is calculated as
weight of rebar per unit length.
Weight of rebar for EN, UNI, and
BS material DB is applied as
shown in the table below.
EN/BS P5 P6 P7 P8 P9 P10 P11 P12 P13 P16 P20 P25 P32 P40
Weight (kg/m) 0.154 0.222 0.302 0.395 0.499 0.617 0.746 0.888 1.043 1.578 2.466 3.853 6.313 9.865
Diameter (mm) 5 6 7 8 9 10 11 12 13 16 20 25 32 40
Area (mm2) 19.6 28.27 38.5 50.27 63.6 78.54 95 113.1 132.7 201.06 314.16 490.87 804.25 1256.6
UNI P4 P5 P6 P8 P10 P12 P14 P16 P18 P20 P22 P24 P26 P30 P32 P36 P40
Weight (kg/m) 0.099 0.154 0.222 0.395 0.617 0.888 1.208 1.578 1.998 2.466 2.984 3.551 4.168 5.549 6.313 7.99 9.865
Diameter (mm) 4 5 6 8 10 12 14 16 18 20 22 24 26 30 32 36 40
Area (mm2) 13 20 28 50 79 113 154 201 254 314 380 452 531 707 804 1018 1257
07 midas Design+
Bolt Connection
Contents
1 Import
2 Input Data
5 Member List
6 Drawing
7
4
Importing connections from midas Gen to midas Design+ works for i-end position of selected members.
The section size of selected member and supporting member, material properties, connection type and design
loading can be imported from midas Gen.
j
1 Case 1 Imported as Beam to Column Connection
2
1. Select a member on Bolt
Connection from the tree
menu. 3
2. Specify Member Name and
the additional task scope
after design. 4
When importing from Gen,
Member Name does not need
to be specified.
Refer page 32 in order to
import the member name. 5
3. Select Connection Type
- Fin Plate (Beam to Beam)
- Fin Plate (Beam to Column)
- End Plate (Beam to Beam) 6
- End Plate (Beam to Column)
- Column Splice (Bearing)
4. Define Material Properties
290 1
3
5
2 1
3 Ved,x 4 Ved,y
4 2
4 1
2
2
1 1
3 3
1 2 Select the cover plate type to define the spacing and extension
Division Plate
The number of bolts per side for Web Cover plate or Cleat
Thickness of Web Cover Plate
1 3
MS Word Report from [Project Mode] PDF Report from [Simple Mode]
06 Drawing
Step
1
1.Select [Drawing] tab.
2. Select [Bolt Connection]
from the drop-down box
and click [Create] button
to generate bolt
connection drawings.
08 midas Design+
Design Parameter
Contents
1 Preference
2 Workbar Reordering
3 Change Member Name in
Workbar
Stair
Change section by Design: Check on to
update section size in Design.
Max. Thick: Check on to specify the
maximum thickness.
1
1. Click General tab.
2. Click Word tab.
Result data
Do not Delete Results Data When Input Data is Changed: Retain design results when
design parameters are changed.
Include design result in Input File(Excel): Check on to include design results in input list
excel report.
Show Apply Button in Member Dialog: Display [Apply] button in Member tab.
Word
Modify default settings of font and text size for MS word report generated from Project
Mode.
1
1. Click Drawing tab.
2. Click File tab.
3. Click Layer tab.
Rebar Name
Use Name by Strength: Check on to enter the rebar name by rebar strength.
Layer
Specify the default line color and line type for drawing.
2a
button to change the
member order. 2b
2c. Click [Apply] and [OK]
button.
2d. Check the updated
member order in Workbar.
Note
The user can simply use drag &
drop on the Workbar to change
the member order.
2c
midas Design+
User Guide
Copyright Since 1989 MIDAS Information Technology Co., Ltd. All rights reserved.