1 Scope............................................................. 2
2 Conflicts and Deviations................................. 2
3 References..................................................... 2
4 General Requirements................................... 3
5 Electrical Requirements................................. 5
6 Design and Construction................................ 6
7 Quality Requirements.................................... 8
8 Identification................................................... 8
9 Instrument Specification Sheet...................... 9
10 Other Miscellaneous Requirements............... 9
1 Scope
This specification defines the minimum requirements for liquid positive displacement
meters for either Process or Custody Metering Applications.
2.1 Any conflicts between this specification and other applicable Saudi Aramco
Materials Systems Specifications (SAMSSs), Engineering Standards (SAESs),
Standard Drawings, (SASDs), or industry standards, codes, and forms shall be
resolved in writing by the Company or Buyer Representative through the
Manager, Process and Control Systems Department of Saudi Aramco, Dhahran.
2.2 Direct all requests to deviate from this specification in writing to the Company or
Buyer Representative, who shall follow internal company procedure SAEP-302
and forward such requests to Manager, Process and Control Systems Department
of Saudi Aramco, Dhahran for Process Metering.
3 References
Material or equipment supplied to this specification shall comply with the latest edition
of the references listed below, unless otherwise noted.
Page 2 of 9
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-118
Issue Date: 28 January 2012
Next Planned Update: 28 January 2017 Positive Displacement Meters
4 General Requirements
Page 3 of 9
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-118
Issue Date: 28 January 2012
Next Planned Update: 28 January 2017 Positive Displacement Meters
4.2.1.1 Temperature
Notes:
1) "Sheltered" refers to permanent, ventilated enclosures or buildings, or permanently
fixed sunshades with a top and three sides.
2) For instruments which dissipate internal heat and are installed in custom engineered
enclosures (e.g., enclosures not included in the original manufacturer's temperature
certification), an additional 15C shall be added to the above maximum temperatures.
An example, for "indoor air conditioned" installation, the equipment must perform at
35 + 15 = 50C. Similarly, for the "outdoor unsheltered" case, the equipment shall be
designed for a maximum operating temperature of 65 + 15 = 80C.
3) For the outdoor installations only, the designer can take credit for forced or passive
cooling to eliminate or reduce the 15C heat rise. For example, if vortex coolers are
used, the heat removal capacity of the coolers may be subtracted from the generated
heat. No more than 15C reduction in temperature will be given as credit. The
designer shall substantiate his claim by providing the support data and calculations.
4.2.1.2 Humidity
4.2.2 Offshore and Nearshore Environment (If specified by the Saudi Aramco
Form 8020-118-ENG)
4.3 Painting
Finish, priming and painting of the PD meter and accessories may be as per the
manufacturer standard provided that the coatings are suitable for the
environmental conditions.
Page 4 of 9
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-118
Issue Date: 28 January 2012
Next Planned Update: 28 January 2017 Positive Displacement Meters
4.4 Enclosures
The instrument manufacturer shall ensure that all equipment installed outdoors
is designed to withstand the environmental conditions.
5 Electrical Requirements
Labeled or
USA Underwriters Laboratories, Inc. (UL)
Listed
USA Factory Mutual Research Corp. (FM) Certified
Canada Canadian Standards Assn. (CSA) Certified
Electrical Equipment Certification Service (EECS)
UK Note: EECS operates the BASEEFA certification Certified
scheme
Belgium Institute National des Industries Extractives (INIEX) Certified
France Laboratoire Central des Industries Electriques (LCIE) Certified
Germany Physikalisch Technische Bundesanstalt (PTB) Certified
Italy Centro Elettrotechnico Sperimentale Italiano (CESI) Certified
Netherlands KEMA Nederland B.V. (KEMA) Certified
Quality Assurance Services (QAS)
Australia Certified
Note: QAS is a subsidiary of Standards Australia
Main electrical power sources for instruments may vary within the limits shown
in Table 1, unless specified otherwise on the ISS.
Page 5 of 9
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-118
Issue Date: 28 January 2012
Next Planned Update: 28 January 2017 Positive Displacement Meters
The positive displacement meter shall be suitable for measuring the process
fluid under the conditions specified on Saudi Aramco Form 8020-118-ENG.
Use of single case meters is permitted if the design pressure is less than
or equal to 1000 kPag (150 PSIG).
6.4.1 Copper or copper alloys shall not be used for meter internals.
6.4.3 Housings
Page 6 of 9
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-118
Issue Date: 28 January 2012
Next Planned Update: 28 January 2017 Positive Displacement Meters
6.5.1.3 Pulse transmitters shall not have a design that involves a film-
type disk with alternating etched opaque and transparent slots.
Page 7 of 9
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-118
Issue Date: 28 January 2012
Next Planned Update: 28 January 2017 Positive Displacement Meters
Type of Service
Royalty/Custody Plant/Process
Transfer Applications
Accuracy, over normal flow range 0.25% 1.0%
Linearity, over normal flow range 0.15% 1.0%
Repeatability, over normal flow range 0.02% 0.5%
Rangeability (nominal) normal flow range * 8:1 10:1
* The ratio of Maximum Continuous Flowrate to Minimum Flowrate.
7 Quality Requirements
The Vendor shall implement and maintain a Quality Program, which shall
include clearly defined and documented procedures for the relevant Quality
System functions. The Quality Program documents shall be made available to
the Buyer Representative for review and audit.
7.2.3 PD Meters shall be factory tested for proper operation when used with
low-lubricity fluids. Certificates of previous testing for same meter type
and same low-lubricity fluid service may be provided in lieu of actual
factory testing.
8 Identification
8.1 The following information shall be stamped/embossed on the stainless steel tag
permanently attached to the meter body:
- Manufacturer
Page 8 of 9
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-118
Issue Date: 28 January 2012
Next Planned Update: 28 January 2017 Positive Displacement Meters
- Part/Model No.
- Serial No.
- Purchase Order No.
- Mark/Tag No.
- Nominal Size
- Flange Rating
- Capacity Data
- K-Factor
8.2 Flow direction shall be indicated by an arrow on the meter body and/or by the
words IN and OUT on the piping connections.
The Vendor shall submit a completed copy of the specification sheet along with his bid.
10.1 Inspection
10.2.2 The supplier shall provide a copy of the manufacturer's sizing software
for pressure drop, rangeability, etc., for the PD meter if available.
10.3 Welding
Vents and drains shall not be seal welded to the meter casing.
Revision Summary
29 January 2012 Revised the "Next Planned Update. Reaffirmed the content of the document, and reissued
with editorial revisions.
Page 9 of 9