Detail 2004-10 9
Detail 2004-10 9
Detail 2004-10 9
Sections
9 scale 1:10
1 double glazing: 12 mm lam. safety glass
+ 6 mm cavity + 8 mm toughened glass
with low-E coating
2 60/60 mm aluminium SHS rail
2 1 3 60/60 mm aluminium SHS post
4 double glazing: lam. safety glass
(2 6 mm float glass) with two to four layers
of coloured PVB film between laminations
+ 16 mm cavity + 8 mm toughened glass
with low-E coating
11 10 3 5 330/24 mm steel connecting plate
at corner
6 100/60/4 mm steel RHS,
bolted to steel core of main facade column
7 57/344 mm lam. softwood secondary facade
column one floor in height
8 57/344 mm lam. softwood main facade
column extending over two floors
with 25/220 mm integral steel core
9 3 mm sheet-aluminium covering
on insulation and 20 mm plywood
12 13 10 grey powder-coated panel,
50 per cent perforated for ventilation
11 aluminium ventilation flap
12 sealing layer
100 mm rigid-foam insulation
vapour barrier
30 mm insulation
2 15 mm plywood on
60/300 mm laminated timber rafters
13 steel plate for fixing suspended
post-and-rail facade
14 200/300/8 mm steel RHS main beam
15 steel fixing plate bolted to facade columns
14 16 aluminium fin
17 aluminium grating over heating duct
18 3 mm grey rubber tiles 600/600 mm
30 mm screed
separating layer
90 mm rigid-foam insulation
400 mm reinforced concrete slab
15 19 3 mm sheet-aluminium insulated panel
16
6
18 17
19
11
cc