RQM5 P5 A 24CC
RQM5 P5 A 24CC
RQM5 P5 A 24CC
RQM * -P
SOLENOID OPERATED PRESSURE
RELIEF VALVES WITH UNLOADING
AND PRESSURE SELECTION
SERIES 60
SUBPLATE MOUNTING
RQM3-P ISO 6264-06 (CETOP R06)
RQM5-P ISO 6264-08 (CETOP R08)
RQM7-P ISO 6264-10 (CETOP R10)
OPERATING PRINCIPLE
NOTE: for the solenoid valve DS3 characteristics see catalogue 41 150
21 310/112 ED 1/4
RQM*-P SERIES 60
1 - IDENTIFICATION CODE
R QM - P / / / 60 - K1 /
Manual override: omit
pilot operated for override integrated
pressure relief in the tube (standard)
valve CM = manual override,
solenoid valve boot protected
for unloading / pressure
selection Coil electrical connection:
plug for connector type
Size: 3 = ISO 6264-06 (CETOP R06) DIN 43650 (standard)
5 = ISO 6264-08 (CETOP R08)
7 = ISO 6264-10 (CETOP R10) DC power supply
Subplate mounting D12 = 12 V
D24 = 24 V
Pressure adjustment range: D48 = 48 V
3 = up to 70 bar 6 = up to 350 bar D110 = 110 V
5 = up to 210 bar D220 = 220 V
D00 = valve without coils (see note)
Versions: A AC power supply
B see description
A24 = 24 V - 50 Hz
@
C in hydraulic symbols
D table A48 = 48 V - 50 Hz
G A110 = 110 V - 50 Hz / 120 V - 60 Hz
A230 = 230 V - 50 Hz / 240 V - 60 Hz
M = adjustment with SICBLOC knob A00 = valve without coils (see note)
available only on the main pressure control
(Omit for adjustment with hexagonal head screw) F110 = 110 V - 60 Hz
F220 = 220 V - 60 Hz
Series No. (the overall and mounting dimensions Seals:
remain unchanged from 60 to 69) N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
NOTE: The locking rings of the coils and the relevant O-Rings are supplied together with valves
2 - VERSIONS
1 pressure setting 1 pressure setting 2 pressure settings 2 pressure settings 3 pressure settings
and unloading with and unloading with The highest setting is and unloading with The highest setting is
de-energized energized solenoid reached with de-energized reached with
solenoid energized solenoid solenoids de-energized solenoids
21 310/112 ED 2/4
RQM*-P SERIES 60
4 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
RQM*-P/D RQM*-P/G
21 310/112 ED 3/4
RQM*-P SERIES 60
6 - MOUNTING SURFACES
26.9 X P T 35
X P T 41.3 P T
32 (max)
X
53.8 70 82.6
14.7 (max) G
G G
ISO 6264-06-09-*-97 (CETOP 4.4.2-2-R06-350) ISO 6264-08-13-*-97 (CETOP 4.4.2-2-R08-350) ISO 6264-10-17-*-97 (CETOP 4.4.2-2-R10-350)
7 - ADJUSTMENT KNOB
The valves can be equipped with a SICBLOC adjustment knob, only on the main pressure regulation.
To operate it, push and rotate at the same time.
To request this option, add: /M (see paragraph 1).
8 - ELECTRIC CONNECTORS
The solenoid valves are never supplied with connector. Connectors must be ordered separately. For the
identification of the connector type to be ordered, please see catalogue 49 000.
Whenever the solenoid valve installation may involve exposure to atmospheric agents or utilization in tropical climates, use of the manual
override boot protected is recommended.
Add the suffix CM to request this device (see paragraph 1). For overall dimensions see catalogue 41 150.
21 310/112 ED REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS. 4/4