Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Masinloc Power Partners Co., LTD

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12

Load table
Static load Dynamic load System switching Emergency rotating Unbalance rotating Seismic load Wind load
4'-958" [1463 mm] No. lbf [kN] lbf [kN] lbf [kN] lbf [kN] lbf [kN] lbf [kN] lbf [kN]
1 FX 836 [3,72] 1967 [8,75]
A A
FY 836 [3,72]
FZ -2581 [-11,48] 1245 [5,54] 2931 [13,04]
2 FX 836 [3,72] 1967 [8,75]
FY 836 [3,72]
Inlet box FZ -2581 [-11,48] 1245 [5,54] 2931 [13,04]

" [560 mm]


3 FX 279 [1,24] 1218 [5,42]
Diffuser Motor
D FY 279 [1,24]
D FZ -861 [-3,83] 416 [1,85] 1816 [8,08]

Impeller casing
4 FX 279 [1,24] 1218 [5,42]

1'-1016
1
Z FY 279 [1,24]
238" [60 mm] soleplate FZ -861 [-3,83] 416 [1,85] 1816 [8,08]

2'-434" [730 mm]


fan: 9'-458" [2860 mm] 5 FX 15152 [67,4] 562 [2,5] 4860 [21,62] 4678 [20,81]
Y A FY 2797 [12,44] 4860 [21,62]
FZ -14999 [-66,72] -344 [-1,53] 15152 [67,4] 562 [2,5] 6603 [29,37] 6355 [28,27]

5'-3" [1600 mm]

5'-1078" [1800 mm]


6 FX 1009 [4,49] 623 [2,77]
FY 279 [1,24] 1009 [4,49]
6'-978" [2080 mm] FZ -3120 [-13,88] -34 [-0,15] 2253 [10,02] 1386 [6,16]
B 115
16" [50 mm] grout B
115 7 FX 1009 [4,49] 623 [2,77]
16" [50 mm] grout
D FY 279 [1,24] 1009 [4,49]
A
FZ -3120 [-13,88] -34 [-0,15] 2253 [10,02] 1386 [6,16]
8 FX 2950 [13,12] 852 [3,79]
3'-1158" [1210 mm] FY 2950 [13,12]
3'-334" [1010 mm] FZ -9103 [-40,49] 634 [2,82] 6985 [31,07] X X
115
16" [50 mm] grout
115 9 FX 2950 [13,12] 852 [3,79]
16" [50 mm] grout
FY 2950 [13,12]
FZ -9103 [-40,49] -634 [-2,82] -6985 [-31,07] X X

16" [100 mm]


10 FX 2889 [12,85] 852 [3,79]
FY 2889 [12,85]
Ground floor EL. 5300
0' [0 mm] FZ -8916 [-39,66] 634 [2,82] 6985 [31,07] X X
11 FX 2889 [12,85] 852 [3,79]

315
FY 2889 [12,85]
FZ -8916 [-39,66] -634 [-2,82] -6985 [-31,07] X X

Notes:
Loads are estimated - may be subject to adjustments
C according to final engineering. C
Static loads are incl. insulation

16" [1700 mm]


Combined oil cabinet Pocket size Pocket size
(drawn relative to FAN A) 70 x 140 D 85 x 85
D

5'-615
Anchor bolt size Anchor bolt size
A 2 pcs. M16 x 450 B 1 pcs. M20 x 500

Shims Shims

15
15

115
105
D
5
8'-1016" [2700 mm] 1'-711
16" [500 mm]
D D

Surface concrete
Surface concrete

Grout 50
Grout 50
400

450
BG

BH
A-A ( 1 : 40 ) D
.
Fan anchor bolts: DIN 13-1; EN ISO 4759-1
D Fan anchor bolts, nuts and washers
Supplied by Howden
B2
22'-478" [6830 mm]

" [1655 mm]

[1030 mm]
4'-238" [1280 mm]

[905 mm]
B ( 1 : 25 )
5'-14" [1530 mm]

0' [0 mm]
Keyplan
2'-1158"

BG

BH
"

1'-134" [350 mm]

BE

BF
E E
5'-516

3'-416
3

D
913
16" [250 mm]
9 4 holes 24 mm
2'-816 " [827,5 mm] B2 B2
0' [0 mm]
FD - FAN A FD - FAN B
6x408=8'-38" [2448 mm] 3'-111
16" [958 mm] 3'-13
16" [935,5 mm] 6'-634" [2000 mm]

1'-334" [400 mm]

1'-434" [425 mm]


4'-213
16" [1290 mm] Foundation bolt B
3'-758" [1108,5 mm]
3'-818" [1120 mm] B2.7 B2.7
3'-478" [1038,5 mm]
8 10
2'-712" [800 mm] B
1 3 1'-678" [480 mm]
20 holes 5 6 B3.5 B3.5
13 Plate 15 mm 5 616 " [160 mm]
F 16" [ 20 mm] F
0' [0 mm] 0' [0 mm]
15
20 holes 16" [ 24 mm]
7
2 4 MASINLOC POWER PARTNERS CO., LTD
HEB120

3'-378" [1013,5 mm] 9 11

3'-858" [1133,5 mm] 3


4'-416 " [1325 mm]

5 Foundation bolt A Foundation bolt B


8'-416" [2548 mm]
2'-1014" [870 mm]
618" [155 mm]
Notes:
BABCOCK & WILCOX
16" [3425 mm])

1. Rotation direction is clockwise when viewed from motor towards fan.


2. Foundation must be according to F-12180. for hubtype B/C.
Foundation design not in Howden scope. dimensions are for guidance only.
2'-1038" [873 mm] 5
2'-816 " [820 mm] 2'-934" [858 mm] access to foundation determined by user requirements.
3. Foundation vibration limits for the fan and motor, MASINLOC POWER PLANT EXPANSION PROJECT B50532EA
X (11'-213

G comply with ANSI/ASA S2.19 (ISO1940) balance quality grade G2.5 G


4. Fan is aligned at ambient temp. ~68 F [~20 C]. during erection.
D (on site) coefficient for steel (7,3*10-6in/in/ F [1.2mm/m/100 C])

B2.7 5.
according to the actual temperature.
Weight of fan w/o insulation: approx. 13466 lbf [59,9 kN] 3-WD100-EM130-00102 D
16" [1700 mm])

6. Weight of insulation: approx. 8273 lbf [36,8 kN]


7. Weight of rotating parts: approx. 6767 lbf [30,1 kN] Surface Projection: Contractor name Babcock & Wilcox
(hub, blades, main shaft and coupling) specification First angle
D Contractor dwg. no.
Combined oil cabinet 8. Rotating parts polar moment of inertia approx. 7859,5 lb*ft [331,2 kg*m ] Howden Axial Fans ApS dd-mm-yyyy Initials
9. All measurements are in ft'-inch" [mm] general standards: Project name Masinloc FD
(drawn relative to FAN B)
X (5'-615

3D model 26-04-2016 AKL


10. For General arrangement drawing, see drawing.: 1252928-9 Tolerances: 01.11.01 Order no. D007832
11. X meassures are determined after final engineering. Surfaces: 01.11.02 Drawn 26-04-2016 AKL
12. This drawing represent FAN B (Left), - FAN A will be mirror (Right) Welding: P-101 Check 28-04-2016 LAH Title Foundation drawing
D 13. The singular unit 'Combined oil cabinet' is drawn in two instances - relative to each FAN
The information and design hereon is the property of
Howden Axial Fans ApS and must not be reproduced, Subject FD Fan
X (1'-711 copied or used without our written consent.
16" [500 mm])
Type ANN-2000/1250C
D Changes acording to comments 11-11-2016 AA -EXT Scale 1:40 Sheet size A1 Sheet 1/1
H H
C Added reference. Keyplan 30-09-2016 AKL JMM
X 5
(8'-1016" [2700 mm]) B Load table updated 17-06-2016 AKL MEP
Load table updated
Howden Axial Fans ApS Drawing no. 1252929-9 Rev. D
A 09-06-2016 AKL MEP DK-4700 Naestved, Denmark
Rev. Description Zone dd-mm-yyyy Initials Check Howden Axial Fans ApS. All rights reserved. 2014 Supersedes Superseded by
1 2 3 4 5 6 7 8 9 10 11 12

0635-321K Vendor Drawing B0342427-3

You might also like