05-1. Standard IO Map
05-1. Standard IO Map
05-1. Standard IO Map
OverseasEngineeringTeam
Chapter5-1.
IOCSTANDARDI/OMAP
Port 1 2 3 4 5 6 7 8 9 10
1 INCN DZ1 CDCF SAFE BRKE CDCFM DZ1M RGC1 D2S FSH1
IOC CNL2-5 CNL5-5 CNHV4-1 CNHV2-3 CNL6-4 CDCFRY DZ1RY CNL8-1 CN2-A5 CN2-A10
2 INCNM DZ2 CDCR SAF2 BRKD CDCRM DZ2M SPARE DZEC ARDFD
IOC CNL2-2 CNL5-6 CNHV5-1 CNHV3-6 CN6-5 CDCRRY DZ2RY CNL8-2 CN2-B5 CN2-B10
3 INCNU SPARE HDIF SAF3 BSLE HDIFM DZE (FSM) dz1m FSI
IOC CNL2-3 CNL9-6 CNHV4-2 CNHV3-2 CNL10-3 HDIFRY INTERNAL CNL9-3 CN2-A6 CN2-A11
4 INCND SPAH0 HDIR SAF4 BSLM HDIRM SEIS (NTSR) dz2m ARDSP
IOC CNL2-4 CN2-A1 CNHV5-2 125 CNL10-4 HDIRRY CNL10-1 CNL9-4 CN2-B6 CN2-B11
5 BRKCD (LVU) CST ARDPI MCC FDIM EPNP (FAN) SDB FALI
A:CNL11-2
IOC BRKCRY don'tuse CNHV2-4 CNL10-2 X CNL9-1 CNL8-5 CN2-A7 CN2-A12
(B:9-5)
6 MCCD (LVD) DLB FSCDM MCD TCH1 (EPA) SAFC SDT MOV
IOC MCCRY don'tuse CNHV4-4 2ER CNL6-2 CNHC1-4 CNL9-2 SAFCRY CN2-B7 CN2-B12
7 SAFCD IRTL DLT FSCDB MCE TCH2 RGOK BRKC BSVAN PUP
IOC SAFCRY CN2-B2 CNHV4-3 2ER CNL6-1 CNHC2-4 CNL8-4 BRKCRY CN2-A8 CN2-A13
8 INRB SPAH4 SPARE SPIOK MCPD SPIOK RGM1 INRBM TSVAN DOB
IOC DIPSW CN2-A3 A:CNL9-5 INTERNAL CNL6-3 INTERNAL CNL8-3 DIPSW CN2-B8 DOBSW
Activehigh Activelow
A:IOC-xA/B:IOC-xB
ThyssenkruppDongyangElevator 1 ModifiedbyJune,2008
OverseasEngineeringTeam
IOCSTANDARDI/OMAPSignalDescription
IOCSTANDARDI/OMAPSignalDescription
SignalDescription
IOname SignalDescription IOname SignalDescription
Door/Levelzone
DZ1 Doorzone#1 DZ1M DZ1relaymonitor
DZ2 Doorzone#2 DZ2M DZ2relaymonitor
DZE Doorzoneenable-Geared,Gearless DZEC Doorzoneenablecontrol-MRL
LVD Leveldown LVU Levelup
Inspection/Temporaryoperation
INCN Inspection-Controller INCNM Normal-Controller
INCNU ControllerInspection-UP INCND ControllerInspection-DOWN
INRB Controllertemporaryoperation INBRM Temporaryoperationswitchmonitor
Brakecontrol/Liftswitch
BRKC BrakerelaycontrolinIOC BRKCD BRKrelaymonitorinIOC
BRKD BrakecontactorNCcontact BRKE BrakecontactorNOcontact
BSLE Brakeliftswitchemergency BSLM BrakeliftswitchMonitor
Motorcontactor/Contactormonitoring
MCC MCCrelaycontrolinIOC MCCD MCCrelaymonitorinIOC
MCPD Motorpilot-contactorNCcontact
MCD MotorcontactorNCcontact MCE MotorcontactorNOcontact
Directionlimitswitch/Slowdownswitch
DLB Directionlimit-Bottom DLT DirectionlimitTop
SDB SlowdownBottom SDT SlowdownTOP
IRTL INSspeedrun-Toplimit)-MRL
Safetycircuitmonitoring/Control
SAFE Safetycircuitmonitor-hoistway CST Safetycircuitmonitor-CAR
SAF2 Safetycircuitmonitor-Door SAF3 Safetycircuitmonitor-Inverter)
SAF4 Safetycircuitmonitor-software)
ThyssenkruppDongyangElevator 2 ModifiedbyJune,2008
OverseasEngineeringTeam
OPTION
2-stepspeedcontrol
BSVAN 2-stepspeedsensor-Bottom TSVAN 2-stepspeedsensorTOP
Ropegripper
RGC1 Ropegripperrelaycontrol RGM1 Ropegrippermonitoring
RGOK Ropegripperconfirmationsignal
Fireservice
FSH1 Fireserviceinputsignal FSI Fireserviceindicator
FSM Fireservicesensor-goestoALTlanding
ARDoperation
ARDPI Auto-rescuedeviceprocessingInput ARDFD ARDfaultdetect
ARDSP ARDStop
2'ndfireoperation
FSCDB 2ndfireoperationrelaycontrol FSCDM 2ndfireoperationrelaymonitor
Emergencypoweroperation
EPNP Emergency/Normalpower EPA EmergencypowerAutomatic
Seismicoperation Nightsilenceoperation
SEIS Seismicsensorinput NTSR Nightsilencesignalinput
Duplextosimplex VIPoperation
D2S DuplextoSimplexcontrol CBx BasefloorVIPCall/Lamp-combo
Spare
SPAHx HighActivesignalinputspare SPARE (CNL8-2)relaycontroloutput(notbeingused)
(FAN) ControllerFANsignal(don'tuseforINPUT)
ThyssenkruppDongyangElevator 3 ModifiedbyJune,2008
OverseasEngineeringTeam
CN-
CN-4AIMSMAP
-.IfyouuseSimpletypeSVP(Supervisorypanel)andMainSVP,thefollowingmapsarerequired.
ThyssenkruppDongyangElevator 4 ModifiedbyJune,2008
OverseasEngineeringTeam
Informationat
nformationatMotionDiagnostic
atMotionDiagnostic-
MotionDiagnostic-position
position
SELECTOR:LostPulsedataorwhenhoistwayscan
DRWDOG-F:Doorsignalisnotinput,halldooropen
SHUNTTRP:FSMsignalinput(theliftwillbestopatnearestfloor)_Floorsetparameter=F11
SEISMIC:Earthquakesignalinput,SEISERClick(WhenJobFileUpLoad)
FIREPH1:FSMsignalinput_floorsetparameter=F10,whenFSH1signalinput
RUNMONTR:
Monitoringsignalisnotinput
->inputTFR(softwarereset)commandinremotefastwindow
INITSHDN:
AfterETSDtest,thiswillbehappened.
InputETSC2timesandstillINITSHDNdisplay,turnINSmodeandNORmodeandreset186Cboard.
->GETcommandinput
XTRNSECUR:whenhall&carcalllock(Blocking)
B44:RefertoPage253
INDEPEND:WhenINDmode
AUTOMATIC:Whenautomode
NOCOMM:Whennocommunication
INCSRISR:WhenhandicapHallButtonCallinput
Sp5:Whenpuch-in(uppeak)timeoperation
LOADBP:Fullloadpasing(LWB)
STOPSW:WhenInspectionmodeinMRLlift
HOMING:WhenParking(HM1)operation
Zoing:
Whenthereisnocarcall&hallcallduringdesignatedtime,theliftwillbemovedtodesignaedfloor
(PARKING)inGroupmode.
EPRECALL:Emergencymainpowersupply(EPNP,EPW)
LWSHUTDN:LWO(100%)(LoadWeigherOverload)
SAFIES:SafetylineOFF
ThyssenkruppDongyangElevator 5 ModifiedbyJune,2008