What is Alignment?
DEW/CBPM LAB
http://boilersinfo.com/
Causes Of Misalignment
Effects Of Misalignment
Types Of Misalignment
1. Off set
2. Angular
DEW/CBPM LAB
http://boilersinfo.com/
Offset Misalignment
DEW/CBPM LAB
http://boilersinfo.com/
Offset Misalignment
DEW/CBPM LAB
http://boilersinfo.com/
DEW/CBPM LAB
Offset Misalignment
0.16
Parallel Misalignment
0.04 Horizontal
&
0.02 Vertical
1 2 3 4 5 6 7 8 9 10
ORDER FREQUENCY DEW/CBPM LAB/JV
http://boilersinfo.com/
0.16
Parallel Misalignment
0.14
0. 12
0.06
0.04 1X 2X
Axial
0.02
1 2 3 4 5 6 7 8 9 10
ORDER FREQUENCY DEW/CBPM LAB/JV
http://boilersinfo.com/
Angular Misalignment
DEW/CBPM LAB
http://boilersinfo.com/
Angular Misalignment
DEW/CBPM LAB
http://boilersinfo.com/
Angular Misalignment
DEW/CBPM LAB
DEW/CBPM LAB
http://boilersinfo.com/
0.16
Angular Misalignment
0.06
Marked by 180 degree phase shift
2X across the coupling in the axial direction
0.04
Axial
0.02
1 2 3 4 5 6 7 8 9 10
ORDER FREQUENCY DEW/CBPM LAB/JV
http://boilersinfo.com/
0.16
Angular Misalignment
0.14
There will also be fairly strong
0. 12 radial 1X and 2X levels,
however these components will
0.10 be in phase.
0.08
0.06
1X 2X
0.04
Vertical
&
0.02
Horizontal
1 2 3 4 5 6 7 8 9 10
ORDER FREQUENCY DEW/CBPM LAB/JV
http://boilersinfo.com/
Skewed Misalignment
DEW/CBPM LAB
http://boilersinfo.com/
Scientific
Diagnosis Of Misalignment
Offset - 1800 phase shift in the radial direction across the coupling. 00 to 1800 phase shift
occur as the sensor moves from horizontal to the vertical direction of the same machine.
Skew - 1800 phase shift in the axial or radial direction across the coupling.
http://boilersinfo.com/
Types Of Couplings
Flexible Coupling
Alignment Methods
1. Rough Alignment
(a) Using straight edge
(b) Twin wire method
2. Precision Alignment
(a) Face & Rim
(b) Reverse indicator
http://boilersinfo.com/
Rough Alignment
Using straight edge
http://boilersinfo.com/
Rough Alignment
Using twin wire
http://boilersinfo.com/
Advantages:
1. Good for large dia. coupling hubs where the shafts are close together.
2. To be used where one of the shafts can not rotate during alignment.
3. Easy to use.
Disadvantages:
1. Difficult to take face readings, if there is axial float in the shaft.
2. Requires removal of coupling spool.
3. More complex alignment calculation.
http://boilersinfo.com/
Advantages:
1. More accurate than face & rim method.
2. Readings are not affected by axial float.
3. Possible to keep the coupling spool.
Disadvantages:
1. Both shafts have to be rotated.
2. Should not be used on close coupled shafts.
3. Difficult to take readings on long shaft.
http://boilersinfo.com/
D/2
http://boilersinfo.com/
Combination Method
Calculation can be
made for each of the
method to verify the
readings.
http://boilersinfo.com/
Alignment Tolerance
Off Set Angular
RPM mm mm / 100 mm
0000 - 1000 0.13 0.10
1000 - 2000 0.10 0.08
2000 - 3000 0.07 0.07
3000 - 4000 0.05 0.06
4000 - 5000 0.03 0.05
http://boilersinfo.com/
Disadvantages Of Dial
Indicator Method
Soft Foot
Short Foot
Angled Foot
http://boilersinfo.com/
Laser Alignment
http://boilersinfo.com/
Laser
Light Amplified By Stimulated Emission Of Radiation
Laser Alignment
Advantages:
1. Easy to use.
2. Use Reverse Indicator Method.
3. Machine does the calculations.
4. 0 - 20m max. working distance.
5. Selectable high resolution 0.1, 0.01, 0.001mm.
6. No indicator sag.
7. Soft foot measurement program.
8. Horizontal shaft alignment with mim 600 rotation.
9. Vertical shaft alignment program.
10.Thermal or offset compensation.
http://boilersinfo.com/
Graphical representation
http://boilersinfo.com/
Graphical representation
+
http://boilersinfo.com/
Graphical representation
Example 1
Scale: Y-axis = 10:1
(Reverse Indicator Method) X-axis = 1: 5
SM Dial Reading: -1.50 mm
MM Dial Reading : +0.5 mm
http://boilersinfo.com/
Graphical representation
+
http://boilersinfo.com/
Jacob Varghese