Astm2241 09 PDF
Astm2241 09 PDF
Astm2241 09 PDF
Designation: D2241 09
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
2
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.
D2241 09
TABLE 1 IPS PVC PipeOutside Diameters and Tolerances
Tolerances, in. (mm)
Maximum Out-of-Roundness
(Maximum Minimum Diameter)
Nominal Pipe Average Outside Diameter,
SDR64,
Size, in. in. (mm) For Average SDR41,
SDR17,
SDR32.5,
SDR13.5
SDR26,
SDR21
18 0.405 (10.29) 60.004 (0.10) 0.030 (0.76) 0.016 (0.41)
14 0.540 (13.72) 60.004 (0.10) 0.030 (0.76) 0.016 (0.41)
3 8 0.675 (17.14) 60.004 (0.10) 0.030 (0.76) 0.016 (0.41)
1 2 0.840 (21.34) 60.004 (0.10) 0.030 (0.76) 0.016 (0.41)
6.1.2 Wall ThicknessThe wall thicknesses and tolerances 6.6 Impact ResistanceThe minimum impact resistance for
shall be as shown in Table 2 when measured in accordance PVC plastic pipe shall be as given in Table 5, when determined
with Test Method D2122. in accordance with 8.7.
6.2 Sustained PressureThe pipe shall not fail, balloon, NOTE 7The impact resistance test is intended for use only as a quality
burst, or weep as defined in Test Method D1598 at the test control test, not as a simulated service test. This test has been found to
pressures given in Table 3 when tested in accordance with 8.4. have no quality control significance in sizes over 12 in. (305 mm).
6.2.1 Accelerated Regression TestThe accelerated regres-
sion test shall be used in place of both the sustained and burst 7. Workmanship, Finish, and Appearance
pressure tests, at the option of the manufacturer. The test shall 7.1 The pipe shall be homogeneous throughout and free
be conducted in accordance with 8.4.1. The pipe shall demon- from visible cracks, holes, foreign inclusions, or other defects.
strate a hydrostatic design basis projection at the 100 000-h The pipe shall be as uniform as commercially practicable in
intercept that meets the hydrostatic design basis category color, opacity, density, and other physical properties.
requirement (see the table for Hydrostatic Design Basis NOTE 8Color and transparency or opacity should be specified in the
Categories of Test Method D2837) for the PVC material used contract or purchase order.
in its manufacture. ( Example: PVC 1120 pipe must have a
minimum 100 000-h projection of 3830 psi and 85 % lower 8. Test Methods
confidence limit (LCL).) 8.1 Conditioning Unless otherwise specified in the appli-
6.3 Burst PressureThe minimum burst pressures for PVC cable test method, condition the test specimens at 73.4 6 3.6F
plastic pipe shall be as given in Table 4, when determined in (23 6 2C) and 50 6 5 % relative humidity for not less than 40
accordance with 8.5. h prior to test in accordance with Procedure A of Practice D618
6.4 FlatteningThere shall be no evidence of splitting, for those tests where conditioning is required.
cracking, or breaking when the pipe is tested in accordance 8.2 Test ConditionsConduct the tests in the standard
with 8.6. laboratory atmosphere of 73.4 6 3.6F (23 6 2C) and 50 6
6.5 Extrusion QualityThe pipe shall not flake or disinte- 5 % relative humidity, unless otherwise specified in the test
grate when tested in accordance with Test Method D2152. methods or in this specification.
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
3
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.
D2241 09
TABLE 2 Wall Thicknesses and Tolerances for PVC Plastic Pipe with IPS Outside Diameters
Wall Thickness,A in.B
Nominal
SDR64 SDR41 SDR32.5 SDR26 SDR21 SDR17 SDR13.5
Pipe
Size, in. Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler-
mum ance mum ance mum ance mum ance mum ance mum ance mum ance
18 ... ... ... ... ... ... ... ... ... ... ... ... 0.060 +0.020
14 ... ... ... ... ... ... ... ... ... ... ... ... 0.060 +0.020
3 8 ... ... ... ... ... ... ... ... ... ... ... ... 0.060 +0.020
1 2 ... ... ... ... ... ... ... ... ... ... ... ... 0.062 +0.020
3 4 ... ... ... ... ... ... ... ... 0.060 +0.020 0.062 +0.020 0.078 +0.020
1 ... ... ... ... ... ... 0.060 +0.020 0.063 +0.020 0.077 +0.020 0.097 +0.020
1 1 4 ... ... ... ... 0.060 +0.020 0.064 +0.020 0.079 +0.020 0.098 +0.020 0.123 +0.020
1 1 2 ... ... ... ... 0.060 +0.020 0.073 +0.020 0.090 +0.020 0.112 +0.020 0.141 +0.020
2 ... ... ... ... 0.073 +0.020 0.091 +0.020 0.113 +0.020 0.140 +0.020 0.176 +0.020
2 1 2 ... ... ... ... 0.088 +0.020 0.110 +0.020 0.137 +0.020 0.169 +0.020 0.213 +0.026
3 ... ... 0.085 +0.020 0.108 +0.020 0.135 +0.020 0.167 +0.020 0.206 +0.025 0.259 +0.031
3 1 2 ... ... 0.098 +0.020 0.123 +0.020 0.154 +0.020 0.190 +0.023 0.235 +0.028 0.296 +0.036
4 0.070 +0.020 0.110 +0.020 0.138 +0.020 0.173 +0.020 0.214 +0.026 0.265 +0.032 0.333 +0.040
5 0.087 +0.020 0.136 +0.020 0.171 +0.021 0.214 +0.027 0.265 +0.032 0.327 +0.039 0.412 +0.049
6 0.104 +0.020 0.162 +0.020 0.204 +0.024 0.255 +0.031 0.316 +0.038 0.390 +0.047 0.491 +0.059
8 0.135 +0.020 0.210 +0.025 0.265 +0.032 0.332 +0.040 0.410 +0.049 0.508 +0.061 ... ...
10 0.168 +0.020 0.262 +0.031 0.331 +0.040 0.413 +0.050 0.511 +0.061 0.632 +0.076 ... ...
12 0.199 +0.024 0.311 +0.037 0.392 +0.047 0.490 +0.059 0.606 +0.073 0.750 +0.090 ... ...
14 ... ... 0.341 +0.048 0.430 +0.052 0.538 +0.064 0.666 +0.080 0.823 +0.099 ... ...
16 ... ... 0.390 +0.055 0.492 +0.059 0.615 +0.074 0.762 +0.091 0.941 +0.113 ... ...
18 ... ... 0.439 +0.061 0.554 +0.066 0.692 +0.083 0.857 +0.103 1.059 +0.127 ... ...
20 ... ... 0.488 +0.068 0.615 +0.074 0.769 +0.092 0.952 +0.114 1.176 +0.141 ... ...
24 ... ... 0.585 +0.082 0.738 +0.088 0.923 +0.111 1.143 +0.137 1.412 +0.169 ... ...
30 ... ... 0.732 +0.102 0.923 +0.111 1.154 +0.138 1.428 +0.171 1.765 +0.212 ... ...
36 ... ... 0.878 +0.123 1.108 +0.133 1.385 +0.166 1.714 +0.205 2.118 +0.254 ... ...
A
The minimum is the lowest wall thickness of the pipe at any cross section. The maximum permitted wall thickness, at any cross section, is the minimum wall thickness
plus the stated tolerance. All tolerances are on the plus side of the minimum requirement.
B
1 in. = 25.4 mm (exact).
TABLE 3 Sustained Pressure Test Conditions for Water at 73F (23C) for PVC Plastic Pipe
PressureA Required for Test
PVC 1120,
SDR PVC 1220,
PVC 2120 PVC 2116 PVC 2112 PVC 2110
psi MPa (bar) psi MPa (bar) psi MPa (bar) psi MPa (bar)
13.5 670 4.62 (46.2) 540 3.72 (37.2) 450 3.10 (31.0) 370 2.55 (25.5)
17 530 3.65 (36.5) 420 2.90 (29.0) 350 2.41 (24.1) 290 2.00 (20.0)
21 420 2.90 (29.0) 340 2.34 (23.4) 280 1.93 (19.3) 230 1.59 (15.9)
26 340 2.34 (23.4) 270 1.86 (18.6) 220 1.52 (15.2) 180 1.24 (12.4)
32.5 270 1.86 (18.6) 210 1.45 (14.5) 180 1.24 (12.4) 150 1.03 (10.3)
41 210 1.45 (14.5) 170 1.17 (11.7) 140 0.97 (9.7) 120 0.83 (8.3)
64 130 0.90 (9.0) 110 0.76 (7.6) 90 0.62 (6.2) 70 0.48 (4.8)
A
The fiber stresses used to derive these test pressures are as follows:
psi MPa (bar)
PVC 1120, PVC 1220, PVC 2120 4200 29.0 (290)
PVC 2116 3360 23.2 (232)
PVC 2112 2800 19.3 (193)
PVC 2110 2300 15.9 (159)
Some minor adjustments have been made to keep the test pressures uniform to simplify testing.
8.3 SamplingThe selection of the sample or samples of ten times the nominal diameter in length, but not less than 10
pipe shall be as agreed upon by the purchaser and the seller. In in. (250 mm) or more than 3 ft (1000 mm) between end
case of no prior agreement, any sample selected by the testing closures and bearing the permanent marking on the pipe.
laboratory shall be deemed adequate. Maintain the specimens at the pressure indicated for a period of
8.3.1 Test SpecimensNot less than 50 % of the test speci- 1000 h. Hold the pressure as closely as possible, but within
mens required for any pressure test shall have at least a part of 610 psi (670 kPa). Condition the specimens at the test
the marking in their central sections. The central section is that temperature of 73.4F (23C) to within 63.6F (2C). Main-
portion of pipe which is at least one pipe diameter away from tain the test temperature at 73.4 6 3.6F (23 6 2C). Test in
an end closure. accordance with Test Method D1598, except maintain the
8.4 Sustained Pressure TestSelect the test specimens at pressure at the values given in Table 3 for 1000 h. Failure of
random. Test individually with water at the internal pressures two of the six specimens tested shall constitute failure in the
given in Table 3, six specimens of pipe, each specimen at least test. Failure of one of the six specimens tested is cause for
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
4
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.
D2241 09
TABLE 4 Burst Pressure Requirements for Water at 73F (23C) the compression is completed within 2 to 5 min. On removal of
for PVC Plastic Pipe the load, examine the specimens for evidence of splitting,
Minimum Burst PressureA cracking, or breaking.
PVC 1120, PVC 2116, 8.7 Impact ResistanceDetermine the impact resistance in
SDR PVC 1220, PVC 2112, accordance with the specification requirement section of Test
PVC 2120 PVC 2110
Method D2444. Test at 73.4 6 3.6F (236 2C) using a Tup B
psi MPa (bar) psi MPa (bar)
and flat plate support. Use a 20-lb (9-kg) tup.
13.5 1000 6.89 (68.9) 800 5.52 (55.2) 8.7.1 Test SpecimensSpecimens of pipe for impact testing
17 800 5.52 (55.2) 630 4.34 (43.4)
21 630 4.34 (43.4) 500 3.45 (34.5) shall be cut to lengths required in Test Method D2444.
26 500 3.45 (34.5) 400 2.76 (27.6) 8.7.2 Test Requirements (14 to 12 in.)For pipe sizes 14
32.5 400 2.76 (27.6) 315 2.17 (21.7) in. (6 mm) through 12 in. (300 mm), ten specimens shall be
41 315 2.17 (21.7) 250 1.72 (17.2)
64 200 1.38 (13.8) 160 1.10 (11.0) tested. If nine or more pass, the lot passes. If two or more fail,
A
The fiber stresses used to derive these test the lot fails.
pressures are as follows:
psi MPa (bar) 9. Retest and Rejection
PVC 1120, PVC 1220, PVC 2120 6400 44.1 (441) 9.1 If the results of any test(s) do not meet the requirements
PVC 2116, PVC 2112, PVC 2110 5000 34.5 (345)
of this specification, the test(s) shall be conducted again only
by agreement between the purchaser and seller. Under such
TABLE 5 Impact Resistance at 73F (23C) for PVC Plastic Pipe agreement, minimum requirements shall not be lowered,
changed, or modified, nor shall specification limits be changed.
Impact Resistance, Impact Resistance,
Size, in.
ftlbf (J) All SDRs
Size, in.
ftlbf (J) All SDRs If upon retest, failure occurs, the quantity of product repre-
14 10 (13.6) 212 40 (54.2)
sented by the test(s) does not meet the requirements of this
12 10 (13.6) 3 60 (81.3) specification.
3 4 15 (20.3) 312 70 (94.9)
1 20 (27.1) 4 90 (122.0) 10. Product Marking
1 1 4 20 (27.1) 5 100 (135.6)
1 1 2 30 (40.7) 6 120 (162.7) 10.1 Marking on the pipe shall include the following,
2 30 (40.7) 8 or larger 160 (216.9) spaced at intervals of not more than 5 ft (1.5 m):
10.1.1 Nominal pipe size (for example, 2 in. (50 mm)),
10.1.2 The outside diameter system (IPS or PIP) on sizes 14
retest of six additional specimens. Failure of one of the six in. (350 mm) and over (for example, IPS 14 in. (350 mm) or
specimens tested in retest shall constitute failure in the test. PIP 21 in. (500 mm)),
Evidence of failure of the pipe shall be as defined in Test 10.1.3 Type of plastic pipe material in accordance with the
Method D1598. designation code given in 3.2.5 (for example, PVC1120),
8.4.1 Accelerated Regression TestTest in accordance with 10.1.4 Standard thermoplastic pipe dimension ratio in ac-
procedures in Test Method D1598, using either free end or cordance with the designation code given in 3.2.4 (for ex-
restrained end fittings. A minimum of six specimens shall be ample, SDR21), or the pressure rating in pounds per square
tested. Test three specimens at a single pressure that result in inch for water at 73F (23C) shown as the number followed
failures at or below 0.10 h. Test an additional three specimens by psi (for example, 200 psi (1.4 MPa)), except that when
at a single pressure that will result in failures at about 200 h. intended for pressure applications, the pressure rating shall be
Generating additional data points to improve the LTHS or shown (for example, 200 psi (1.4 MPa)). When the indicated
LCL, or both, is acceptable. No points shall be excluded unless pressure rating is lower than that calculated in accordance with
an obvious defect is detected in the failure area of the test 3.2.3 (see appendix), the SDR shall also be included in the
sample, or there was a malfunction of test equipment. Charac- marking code,
terize the data using the least squares regression described in 10.1.5 ASTM designation D2241, with which the pipe
Test Method D2837. complies,
8.5 Burst PressureDetermine the minimum burst pressure 10.1.6 Manufacturers name (or trademark),
with at least five specimens in accordance with Test Method 10.1.7 Production code with which the manufacturer can
D1599, having the lengths specified in 8.4. The time of testing trace the year, month, day shift, plant and extruder of manu-
of each specimen shall be not less than 60 s. facture for this product, and
NOTE 9Times greater than 60 s may be needed to bring large size 10.1.8 Pipe intended for the transport of potable water shall
specimens to the burst pressure. The test is more difficult to pass using also include the seal or mark of the laboratory making the
greater pressurizing times. evaluation for this purpose, spaced at intervals specified by the
8.6 FlatteningFlatten three specimens of the pipe, 2 in. laboratory.
(50 mm) long, between parallel plates in a suitable press until NOTE 10Manufacturers using the seal or mark of a laboratory must
the distance between the plates is 40 % of the outside diameter obtain prior authorization from the laboratory concerned.
of the pipe. The rate of loading shall be uniform and such that
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
5
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.
D2241 09
11. Quality Assurance 12. Keywords
11.1 When the product is marked with this designation, 12.1 pressure pipe; pressure rated; PVC; SDR
D2241, the manufacturer affirms that the product was manu-
factured, inspected, sampled, and tested in accordance with this
specification and has been found to meet the requirements of
this specification.
SUPPLEMENTARY REQUIREMENTS
This requirement applies whenever a regulatory authority or user calls for product to be used to
convey or to be in contact with potable water.
S1. Potable Water RequirementProducts intended for the health effects portion of NSF Standard No. 14 by an
contact with potable water shall be evaluated, tested, and acceptable certifying organization when required by the regu-
certified for conformance with ANSI/NSF Standard No. 61 or latory authority having jurisdiction.
This requirement applies only to pipe to be used in systems that have not established other provisions for identification.
S2. Pipe Marking Requirement for Reclaimed Water stripes printed lengthwise on opposite sides of the pipe. The
SystemsColor Identification of pipe shall be by: (1) use of pipe shall be marked RECLAIMED WATER at intervals of 5
purple (violet) PVC material or (2) by use of continuous purple ft. or less.
ANNEX
(Mandatory Information)
A1. PVC PRESSURE RATED PIPES HAVING OTHER THAN IPS OUTSIDE DIAMETERS
A1.1 As the use of PVC pipe has expanded, a need for pipe TABLE A1.2 PIP Outside Diameters and Tolerance for PVC
diameters and dimension ratios other than those listed in the Plastic Pipe
main body of this specification has developed. These include Tolerances, in. (mm)
Nominal Tube Average Outside
small diameter (2-in. and under) CTS sizes and larger diameter Size, in. Diameter, in. (mm) Average
Maximum
(6 in. and over) PIP sizes. The IPS outside diameter pipes and Out-of-Roundness
the standard dimension ratios included in the body of this 6 6.140 (155.96) 60.011 (0.28) 0.100 (2.54)
8 8.160 (207.26) 60.15 (0.38) 0.150 (3.81)
specification provide the format onto which these additional 10 10.200 (259.08) 60.15 (0.38) 0.150 (3.81)
sizes are fitted. 12 12.240 (310.90) 60.15 (0.38) 0.150 (3.81)
15 15.300 (388.62) 6 .016 (0.41) 0.294 (7.46)
A1.2 Pipe sizes listed in this Annex shall be tested to verify 18 18.701 (475.00) 6 .020 (0.51) 0.360 (9.14)
21 22.047 (559.99) 6 .025 (0.64) 0.420 (10.66)
they meet the requirements shown in Tables A1.1-A1.7 and all 24 24.803 (629.99) 6 .032 (0.81) 0.480 (12.20)
other requirements of the specification. 27 27.953 (710.00) 6 .038 (0.96) 0.540 (13.72)
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
6
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.
D2241 09
TABLE A1.4 Burst Pressure Test Conditions for Water at 73.4F
(23C) for PVC Plastic PipeA
Pressure Required for TestPVC 1120
SDR psi MPa Bars
11 1280 8.82 88.2
35 380 2.62 26.2
51 260 1.79 17.9
81 160 1.085 10.85
A
The fiber stress used to derive this test was 6400 psi (44.1 MPa).
TABLE A1.6 Wall Thicknesses and Tolerances for PVC Plastic pipe with CTS Outside DiametersA
Wall Thickness, in. (mm)B
Nominal Tube
SDR 21 SDR 17 SDR 13.5 SDR 11
Size, in.
Minimum Tolerance Minimum Tolerance Minimum Tolerance Minimum Tolerance
12 ... ... ... ... 0.060 +0.020 0.060 +0.020
34 ... ... 0.060 +0.020 0.065 +0.020 0.080 +0.020
1 0.060 +0.020 0.066 +0.020 0.083 +0.020 0.102 +0.020
1 1 4 0.065 +0.020 0.081 +0.020 0.102 +0.020 0.125 +0.020
1 1 2 0.077 +0.020 0.096 +0.020 0.120 +0.020 0.148 +0.020
2 0.101 +0.023 0.125 +0.023 0.157 +0.023 0.193 +0.023
A
The minimum is the lowest wall thickness of the pipe at any cross section. The maximum permitted wall thickness, at any cross-section, is the minimum wall thickness
plus the stated tolerance. All tolerances are on the plus side of the minimum tolerance.
B
1 in. = 25.4 mm (exact).
TABLE A1.7 Wall Thicknesses and Tolerances for PVC Plastic Pipe with PIP Outside DiametersA
Wall Thickness, in. (mm)B
Nominal
SDR81 SDR51 SDR41 SDR35 SDR32.5 SDR26 SDR21
Pipe
Size, in. Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler- Mini- Toler-
mum ance mum ance mum ance mum ance mum ance mum ance mum ance
6 0.076 +0.020 0.120 +0.020 0.150 +0.020 ... ... 0.189 +0.023 ... ... ... ...
8 0.101 +0.020 0.160 +0.020 0.199 +0.024 ... ... 0.251 +0.030 ... ... ... ...
10 0.126 +0.020 0.200 +0.024 0.249 +0.030 ... ... 0.314 +0.038 ... ... ... ...
12 0.151 +0.020 0.240 +0.029 0.299 +0.036 ... ... 0.377 +0.045 ... ... ... ...
15 0.189 +0.023 0.300 +0.042 0.373 +0.052 0.437 +0.052 0.471 +0.056 0.588 +0.070 0.728 +0.087
18 ... ... 0.366 +0.051 0.456 +0.064 0.534 +0.064 0.575 +0.069 0.719 +0.086 ... ...
21 ... ... 0.432 +0.060 0.538 +0.075 0.630 +0.076 0.678 +0.081 0.848 +0.102 ... ...
24 ... ... 0.486 +0.068 0.605 +0.085 0.709 +0.085 0.763 +0.092 0.954 +0.115 ... ...
27 ... ... 0.548 +0.077 0.682 +0.095 0.799 +0.096 0.860 +0.103 1.075 +0.129 ... ...
A
1 in. = 25.4 mm (exact).
B
The minimum is the lowest wall thickness of the pipe at any cross section. The maximum permitted wall thickness, at any cross section, is the minimum wall thickness
plus the stated tolerance. All tolerances are on the plus side of the minimum requirement.
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
7
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.
D2241 09
APPENDIX
(Nonmandatory Information)
TABLE X1.1 Standard Thermoplastic Pipe Dimension Ratios (SDR) and Water Pressure Ratings (PR) at 73F (23C) for Nonthreaded
PVC Plastic PipeA
Pressure Rating of PVC Pipe MaterialsA
SDR PVC 1120, PVC 2116 PVC 2112 PVC 2110
PVC 1220,
PVC 2120
psi MPa (bar) psi MPa (bar) psi MPa (bar) psi MPa (bar)
13.5 315 2.17 (21.7) 250 1.72 (17.2) 200 1.38 (13.8) 160 1.10 (11.0)
17 250 1.72 (17.2) 200 1.38 (13.8) 160 1.10 (11.0) 125 0.86 (8.6)
21 200 1.38 (13.8) 160 1.10 (11.0) 125 0.86 (8.6) 100 0.69 (6.9)
26 160 1.10 (11.0) 125 0.86 (8.6) 100 0.69 (6.9) 80 0.55 (5.5)
32.5 125 0.86 (8.6) 100 0.69 (6.9) 80 0.55 (5.5) 63 0.43 (4.3)
41 100 0.69 (6.9) 80 0.55 (5.5) 63 0.43 (4.3) 50 0.34 (3.4)
64 63 0.43 (4.3) 50 0.34 (3.4) NPRC NPRC NPRC NPRC
Pressure RatingABC Standard Dimension Ratio of PVC Pipe Materials
psi MPa (bar) PVC 1120, PVC 2116 PVC 2112 PVC 2110
PVC 1220,
PVC 2120
315 27.17 (21.7) 13.5 ... ... ...
250 1.72 (17.2) 17 13.5 ... ...
200 1.38 (13.8) 21 17 13.5 ...
160 1.10 (11.0) 26 21 17 13.5
125 0.86 (8.6) 32.5 26 21 17
100 0.69 (6.9) 41 32.5 26 21
80 0.55 (5.5) ... 41 32.5 26
63 0.43 (4.3) 64 ... 41 32.5
50 0.34 (3.4) ... 64 ... 41
A
These pressures ratings do not apply for threaded pipe.
B
See 3.2.5 and 5.3 for code designation.
C
NPR = not pressure rated.
X1.1 The hydrostatic design stresses recommended by the for thermoplastic pipe materials is Test Method D2837. Addi-
Plastics Pipe Institute are used to pressure rate PVC plastic tional information regarding the criteria used in developing
pipe. These hydrostatic design stresses are 2000 psi (14 MPa), these hydrostatic design stresses may be obtained from the
1600 psi (11.0 MPa), 1250 psi (8.6 MPa), and 1000 psi (6.9 Plastics Pipe Institute.5 These hydrostatic design stresses may
MPa) for water at 73.4F (23C). These hydrostatic design not be suitable for materials that show a wide departure from
stresses apply only to pipe meeting all the requirements of this a straight line plot of log stress versus log time to failure. All
specification. the data available to date on PVC pipe materials made in the
United States exhibit a straight-line plot under these plotting
X1.2 Six PVC pipe materials are included based on the
conditions.
requirements of Specification D1784 and the PPI-
recommended hydrostatic design stresses as follows: X1.4 The pipe is rated for use with water in 73F (23C) at
X1.2.1 Type I, Grade 1 (12454-B), with a hydrostatic design the maximum internal pressures shown in Table X1.1. Lower
stress of 2000 psi (14 MPa), designated as PVC1120. pressure ratings than those calculated in accordance with 3.2.3
X1.2.2 Type I, Grade 2 (12454-C), with a hydrostatic design may be recommended, at the option of the pipe manufacturer,
stress of 2000 psi (14 MPa), designated as PVC1220. in which case the SDR shall be included in the marking.
X1.2.3 Type II, Grade 1 (14333-D), with a hydrostatic Experience of the industry indicates that PVC plastic pipe
design stress of 2000 psi (14 MPa), designated as PVC2120. meeting the requirements of this specification give satisfactory
X1.2.4 Type II, Grade 1 (14333-D), with a hydrostatic service under normal conditions for a long period at these
design stress of 1600 psi (11.0 MPa), designated as PVC2116. pressure ratings. The sustained pressure requirements (6.3) are
X1.2.5 Type II, Grade 1 (14333-D), with a hydrostatic related to these ratings through the slopes of the strength-time
design stress of 1250 psi (8.6 MPa), designated as PVC2112. plots of these materials in pipe form.
X1.2.6 Type II, Grade 1 (14333-D), with a hydrostatic 5
Available from Plastics Pipe Institute (PPI), 105 Decker Court, Suite 825,
design stress of 1000 psi (7 MPa), designated as PVC2110. Irving, TX 75062, http://www.plasticpipe.org.
X1.3 The standard method for obtaining hydrostatic basis
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
8
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.
D2241 09
X1.5 The hydrostatic design stresses recommended by the
Plastic Pipe Institute are based on tests made on pipe ranging
in size from 12 to 212 in. (12.5 to 50 mm).
SUMMARY OF CHANGES
Committee F17 has identified the location of selected changes to this standard since the last issue (D224105)
that may impact the use of this standard.
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/
COPYRIGHT/).
Copyright by ASTM Int'l (all rights reserved); Fri Jul 1 12:36:10 EDT 2011
9
Downloaded/printed by
Jalusa Soares (Tigre+S.A+-+Tubos+e+Conexoes) pursuant to License Agreement. No further reproductions authorized.