75 Kva
75 Kva
75 Kva
B series
with user friendly PCC 0301 genset controller
Specification sheet
66-112 kWe, 82.5-140 kVA Prime
PowerCommand® genset controller: Genset controller for Genset controller: (For 140 KVA)
true power system reliability, flexibility, and ease of use. Cummins PowerCommand ® PCC 1301 is a microprocessor
based integrated generator set monitoring, metering, protection
Genset controller: (For 75-125 KVA) and control system with built-in torque matched Volts/Hz
Cummins PowerCommand™ PCC 0301 overload control.
control is a microprocessor based
generator set monitoring and control Single control for all
system mounted in the Genset Control genset functions:
Panel. The control provides a simple - Digital governing
operator interface to the generator set, - Digital voltage control
manual and remote start/stop control, shutdown fault indication, - Engine control
and an LCD hour counter. The integration of all functions into a - Operator interface
single control system provides enhanced reliability and - Protection
performance compared to conventional generator set control - Advanced control functions
systems.
Standard features of genset controller:
The controller with Keyswitch / Autostart functionality has a
Engine
Multifunction Meter which displays the below mentioned
Metering Protection
parameters : - RPM - Low lube oil pressure - Fail to crank
- Voltage - Water temperature - kVA - Battery voltage - High water temp. - Fail to start
- Current - Oil pressure - kW - Lube oil pressure - High /low DC voltage - Sensor failure
- Coolant temp. - Weak battery
- Frequency
- Running hours - Overspeed
Control system: The standard control system includes all the Alternator
functions necessary to locally or remotely start and stop and Metering Protection
protect the generator set. - 3 phase voltage - Under voltage - Field overload
(L-L and L-N) - Over voltage
- Key switch – OFF and MANUAL/AUTO - In the OFF mode, the
- 3 phase current - Over current
generator set is immediately shut down (if running) and cannot - Frequency - Under/ over-frequency
be started. It also resets any faults. In this mode, all power is - kVA - Loss of sensing
removed from the control and its outputs. In MANUAL/AUTO
mode, the control is powered. The manual start pushbutton Others
- Battle switch function
and remote start input become enabled.
- Delay start/ stop
- Manual start button – This button will initiate a genset start - Configurable cranking cycle
sequence when the control is in MANUAL/AUTO mode. This - Sleep mode time
button is locked out when the engine is running.
www.cumminsindia.com
Our energy working for you.TM
© 2008 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation
and Cummins are registered trademarks of Cummins Inc. PowerCommand is a registered
trademark of Cummins Power Generation Inc. “Our energy working for you.” is a trademark
of Cummins Power Generation.
PGBU/CIL/004/B 75-140 kVA/CPG/90Deg./March 2008/Qty.
Acoustic enclosure: - Use of special hardware for longer life
- Insulation material meets exacting IS 8183 specifications for
The acoustic enclosure is made of 1.6/ 2 mm thick CRCA
better sound attenuation
sheets in Munsel green shade and a structural/ sheet metal base
- Flush styling - no projections
frame painted in black. The walls of the enclosure are insulated
- Fluid drains for lube oil and fuel
with fire retardant foam so as to comply with the 75 dBA at mtr
- Fuel filling point
sound levels specified by Ministry of Environment & Forest.
Others:
The enclosure has the following features:
- Specially designed to meet stringent MOEF/ CPCB norms of - Fuel tank suitable for 8 hours of operation
75 dBA @ 1mtr at 75% load under free field conditions
- Single point lifting for easy handling at customer site Optionals
- Designed to have optimum serviceability
- Heavy duty air cleaner
- Air inlet louvers specially designed to operate at rated load -
- Microprocessor / relay based AMF control panel
Made on special purpose CNC machines for consistency in
- Trolley mounted mobile sets
quality and workmanship
- Cold starting kit
- Powder coated for long lasting service life and superior finish
- Electronic governor
- With UV resistant powder coating, can withstand extreme
- Lube oil heater
environments
Technical data
Generator set specifications
Model C 75 D5 P / C 82.5 D5 P C 100 D5 P C 125 D5 P C 140 D5 P
Prime Power Rating kVA / kW 75 kVA /60 kW / 82.5 kVA / 66 kW 100 kVA /80 kW 125 kVA /100 kW 140 kVA /112 kW
Current (Amps) 104 / 115 139 174 195
No. of Phases 3 Phase 3 Phase 3 Phase 3 Phase
Power Factor 0.8 (lag) 0.8 (lag) 0.8 (lag) 0.8 (lag)
Engine specifications
Make Cummins Cummins Cummins Cummins
Model 6BT5.9G1 6BTA5.9G1-I 6BTA5.9G2-I 6BTAA 5.9G1-I
BHP 105 124 154 170
Cooling Water Cooled Water Cooled Water Cooled Water Cooled
Aspiration Turbocharged Turbocharged Turbocharged Turbocharged
Aftercooled Aftercooled Charged Air Cooled
No. of Cylinders 6 6 6 6
RPM 1500 1500 1500 1500
Bore (mm) x Stroke (mm) 102 x 120 102 x 120 102 x 120 102 x 120
Compression Ratio 17.6:1 17.6:1 17.6:1 17.6:1
Displacement (Ltrs.) 5.88 5.88 5.88 5.88
Fuel HSD HSD HSD HSD
Fuel Consumption (Ltr/hr) @ 75% Load 14.3 16.9 20.8 22.9
with Radiator & Fan
Governor Mechanical Mechanical Mechanical Electronic
Starting System 12 V Electrical 12 V Electrical 12 V Electrical 12 V Electrical
Lube oil Specification CF4 15W40 CF4 15W40 CF4 15W40 CF4 15W40
Lube oil Sump Capacity (Ltrs.) 14.3 14.3 14.3 14.3
Lube oil consumption (LPH) 0.04 / 0.047 0.026 0.03 0.04
Total Coolant Capacity (Ltrs.) 22 24.5 24.5 24.5
Exhaust Pipe Size (mm) 100 100 100 100
Battery Capacity / Rating 150 AH 12 V 150 AH 12 V 150 AH 12 V 150 AH 12 V
Alternator specifications
Voltage 380 / 415 380 / 415 380 / 415 380 / 415
RPM / Frequency 1500 / 50 Hz 1500 / 50 Hz 1500 / 50 Hz 1500 / 50 Hz
Enclosure IP 23 IP 23 IP 23 IP 23
Voltage Regulation (max) +/- 1% +/- 1% +/- 1% +/- 1%
Class of Insulation H Class H Class H Class H Class
Recommended Cable size x Runs 95 x 1 120 x 1 185 x 1 or 95 x 2 240 x 1 or 120 x 2
(Al Armoured 3 1/2 core)
www.cumminsindia.com
Our energy working for you.TM
© 2008 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation
and Cummins are registered trademarks of Cummins Inc. PowerCommand is a registered
trademark of Cummins Power Generation Inc. “Our energy working for you.” is a trademark
of Cummins Power Generation.
PGBU/CIL/004/B 75-140 kVA/CPG/90Deg./March 2008/Qty.
Conformance standards Emergency Standby Power (ESP):
Applicable for supplying power to varying electrical load for
IS 4722, BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046 the duration of power interruption of a reliable utility source.
Emergency Standby Power (ESP) is in accordance with
Rating definitions ISO 8528. Fuel Stop power in accordance with ISO 3046,
Prime Power (PRP): AS 2789, DIN 6271 and BS 5514.
Applicable for supplying power to varying electrical load for
unlimited hours. Prime Power (PRP) is in accordance with - Fuel consumption data is based on diesel having specific
ISO 8528. Ten percent overload capability is available in gravity of 0.85 and conforming to IS:1460
accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. - Oil consumption data is based on oil having specific gravity of
0.89 and meeting CF4 API categories
- Fuel consumption tolerance is +5%
www.cumminsindia.com
Our energy working for you.TM
© 2008 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation
and Cummins are registered trademarks of Cummins Inc. PowerCommand is a registered
trademark of Cummins Power Generation Inc. “Our energy working for you.” is a trademark
of Cummins Power Generation.
PGBU/CIL/004/B 75-140 kVA/CPG/90Deg./March 2008/Qty.