Surface resistivity measurement provides extremely useful information about the state of a concrete
structure. Not only has it been proven to be directly linked to the likelihood of corrosion and the
corrosion rate, recent studies have shown that there is a direct correlation between resistivity and
chloride diffusion rate. The versatility of the method can be seen in these example applications:

• Estimation of the likelihood of corrosion


• Indication of corrosion rate
• Correlation to chloride permeability
• On site assessment of curing efficiency
• Determination of zonal requirements for cathodic protection systems
• Identification of wet and dry areas in a concrete structure
• Indication of variations in the water/cement ratios within a concrete structure
• Identification of areas within a structure most susceptible to chloride penetration
• Correlation to water permeability of rock

Resipod is a fully integrated 4-point Wenner probe, designed to measure the electrical resistivity of concrete
in a completely non-destructive test. It is the most accurate instrument available, extremely fast and stable
and packaged in a robust, waterproof housing designed to operate in a demanding site environment.

Made in Switzerland
The measurement principle

Operating on the principle of the


Wenner probe, the Resipod is designed
to measure the electrical resistivity of
concrete or rock. A current is applied to
the two outer probes, and the potential
difference is measured between the two
inner probes. The current is carried by
ions in the pore liquid. The calculated
resistivity depends on the spacing of the
probes.

Resistivity ρ= 2πaV/l [kΩcm]

Resipod Models and Probe Spacing

A wider probe spacing provides a more consistent


reading when measuring on an inhomogeneous
material like concrete. However, if the spacing is too
wide, there is more danger of the measurement being
affected by the reinforcement steel. The industry
standard 50 mm probe spacing has long been seen
as a good compromise.

The 38mm (1.5”) model is designed specifically to comply with the AASHTO T 358 standard for “Surface Re-
sistivity Indication of Concrete’s Ability to Resist Chloride Ion Penetration”.

The Surface Resistivity (SR) test is a much quicker and easier test for estimating concrete permeability. It is a
proven and mature test method which can replace the more laborious rapid chloride permeability test.

Made in Switzerland
Unmatched Features
Despite being extremely simple to use, Resipod provides a variety of features that are unique in a concrete
surface resistivity instrument.

• Fully integrated surface resistivity instrument


• Wide measuring range (0 to ca. 1000 kΩcm)
• Fast and accurate delivery of measuring results
• Highest resolution available for a surface resistivity instrument
• Meets the AASHTO T 358 standard (38mm, 1.5” probe spacing)
• Current flow indication and poor contact indication
• Hold, save and delete function, with onboard memory
• USB connection and dedicated PC software
• Designed to float (waterproof according to IP67)
• Allows variable probe spacing to be set
• Allows replacement of standard tips with accessories

Resipod Display
The display of the Resipod shows all necessary information while acquiring data on site.

1. Measured resistivity
2. Battery status
3. Range indication
4. Current indication
20%, 40%, 60%, 80%, 100%
5. Indication of scaled reading

Indication of poor connection


A good connection between the instrument and the concrete surface is the most important factor for obtaining
a reliable measurement. Resipod automatically detects a poor connection and alerts the user.

No contact inner probes Overflow “Open Line” indication


ResipodLink Software
The collected measurement values can then be analyzed comfortably with the Resipod Link PC tool.

Made in Switzerland
Technical Information Resipod
Range 0.1 – ca. 1000 kΩcm (depending on probe spacing)
Resolution (nominal current 200μA) ±0.2 kΩcm or ±1% (whichever is greater)
Resolution (nominal current 50μA) ±0.3 kΩcm or ±2% (whichever is greater)
Resolution (nominal current <50μA) ±2 kΩcm or ±5% (whichever is greater)
Frequency 40 Hz
Memory Non volatile, ca. 500 measured values
Power Supply >50 hours autonomy
Charger connection USB type B, (5V, 100mA)
Dimensions 197 x 53 x 69.7 mm (7.8 x 2.1 x 2.7 inch)
Weight 318 g (11.2 oz)
Operating temperature 0° to 50°C (32° to 122°F)
Storage temperature -10° to 70°C (14° to 158°F)
IP Classification IP67

Technical Information Resipod Link software


System requirements: Windows XP, Windows Vista, Windows 7, USB-Connector
An internet connection is necessary for soft- and firmware (using PqUpgrade) updates if available.

Ordering Information
Units Description
381 10 000 Resipod, 50mm probe spacing, test strip, foam contact pads, charger with USB-
cable, software, carrying strap, documentation and case.
381 20 000 Resipod, 38mm (1.5”) probe spacing, test strip, foam contact pads, charger with
USB-cable, software, carrying strap, documentation and case.
Parts and Accessories
381 01 050 Extension cable set
381 01 043S Set of replacement foam contact pads (20 pieces)
381 01 038 Test strip
381 01 014 USB cover
391 80 110 Carrying strap
341 80 112 USB charger, global

Service and Warranty Information


Proceq is committed to providing complete support for
the Resipod testing instrument by means of our global
service and support facilities. Furthermore, each instrument
is backed by the standard Proceq 2-year warranty and
extended warranty options.

Standard warranty
Electronic portion of the instrument: 24 months
Mechanical portion of the instrument: 6 months

Extended warranty
When acquiring a Resipod, max. 3 additional warranty years can be purchased (for the electronic portion of the
instrument). The additional warranty must be requested at time of purchase or within 90 days of purchase.
Subject to change without notice. All information contained in this documentation is presented in good faith and believed to be correct. Proceq SA makes no warranties
and excludes all liability as to the completeness and/or accuracy of the information. For the use and application of any product manufactured and/or sold by Proceq SA
explicit reference is made to the particular applicable operating instructions.

Head Office

Proceq SA
Ringstrasse 2
CH-8603 Schwerzenbach
Switzerland
Phone: +41 (0)43 355 38 00
Fax: +41 (0)43 355 38 12
info@proceq.com
www.proceq.com

81038101E ver. 12 2016 © Proceq SA, Switzerland. All rights reserved.

You might also like