Indradrive Diagnostic Old
Indradrive Diagnostic Old
Indradrive Diagnostic Old
Rexroth IndraDrive
R911297319
Edition 01
Troubleshooting Guide
About this Documentation Rexroth IndraDrive
Validity The specified data is for product description purposes only and may not
be deemed to be guaranteed unless expressly confirmed in the contract.
All rights are reserved with respect to the content of this documentation
and the availability of the product.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Contents I
Contents
1 Basics on Device Diagnosis 1-1
1.1 Diagnostic System ........................................................................................................................ 1-1
Coded Diagnostic Drive Messages.......................................................................................... 1-1
Status Classes, Status Displays, Control Parameters............................................................. 1-4
1.2 Control Panel of the IndraDrive Controllers .................................................................................. 1-9
Brief Description....................................................................................................................... 1-9
Functional Description ........................................................................................................... 1-10
Notes on Commissioning ....................................................................................................... 1-16
1.3 Extended Diagnostic Possibilities ............................................................................................... 1-16
1.4 Kinds of Diagnostic Messages.................................................................................................... 1-16
Error ....................................................................................................................................... 1-16
Warnings ................................................................................................................................ 1-17
Commands............................................................................................................................. 1-18
States/Operating States......................................................................................................... 1-18
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
II Contents Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Contents III
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
IV Contents Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Contents V
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
VI Contents Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Contents VII
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
VIII Contents Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Contents IX
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
X Contents Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Contents XI
C0156 Field bus: IDN for cycl. actual val. not configurable ................................................... 9-43
C0157 Field bus: length for cycl. actual values exceeded..................................................... 9-43
C0158 Field bus: Tcyc (P-0-4076) incorrect .......................................................................... 9-44
C0159 Field bus: P-0-4077 missing for cycl. command values............................................. 9-44
C0160 Error when reading encoder data => measuring encoder ......................................... 9-45
C0161 Incorr. prarmeterization of measuring enc. (hardware).............................................. 9-46
C0162 Measuring encoder unknown ..................................................................................... 9-47
C0163 Modulo value for measuring encoder cannot be displayed........................................ 9-48
C0164 Incorrect measuring encoder configuration................................................................ 9-48
C0199 Functional package selection changed. Restart ........................................................ 9-49
C0201 Invalid parameters (->S-0-0022) ................................................................................ 9-49
C0202 Parameter limit error (->S-0-0022) ............................................................................. 9-50
C0203 Parameter calculation error (->S-0-0022) .................................................................. 9-50
C0212 Invalid control section data (->S-0-0022) ................................................................... 9-51
C0220 Error when initializing position of encoder 1 .............................................................. 9-52
C0221 Initialization velocity encoder 1 too high..................................................................... 9-53
C0224 Error when initializing position of encoder 2 .............................................................. 9-54
C0225 Initialization velocity encoder 2 too high..................................................................... 9-55
C0227 Error when initializing position of measuring encoder................................................ 9-56
C0228 Initialization velocity measuring encoder too high...................................................... 9-57
C0242 Multiple configuration of a parameter (->S-0-0022) ................................................... 9-58
C0243 Brake check function not possible.............................................................................. 9-59
C0244 Act. modulo value cycle greater than max. travel range ............................................ 9-59
C0245 Operating mode configuration (->S-0-0022) not allowed........................................... 9-60
C0246 Trav. range lim. switch not ass. to dig. input .............................................................. 9-61
C0247 Dig. output already assigned to other axis ................................................................. 9-61
C0248 Dig. input assigned differently to axes ....................................................................... 9-62
C0249 Dig. I/Os: bit number too large ................................................................................... 9-62
C0250 Probe inputs incorrectly configured............................................................................ 9-63
C0251 Error during synchronization to master communication............................................. 9-63
C0255 Safety command for system init. incorrect ................................................................. 9-64
C0257 No encoder assigned to slot 1.................................................................................... 9-65
C0258 Error in relation TNcyc (S-0-0001) to fine interpol. .................................................... 9-66
C0260 Incremental enc. emulator resol. cannot be displayed............................................... 9-67
C0301 Measuring system unavailable................................................................................... 9-68
C0302 Absolute evaluation of measuring system impossible ............................................... 9-68
C0303 Absolute encoder offset cannot be saved .................................................................. 9-69
C0401 Drive active, switching not allowed ............................................................................ 9-69
C0501 Error clearing only in parameter mode....................................................................... 9-70
C0601 Homing only possible with drive enable ..................................................................... 9-70
C0602 Distance home switch - reference mark erroneous ................................................... 9-71
C0604 Homing of absolute encoder not possible .................................................................. 9-72
C0606 Reference mark not detected..................................................................................... 9-73
C0607 Reference cam input not assigned............................................................................. 9-74
C0702 Default parameters not available ............................................................................... 9-74
C0703 Default parameters invalid ......................................................................................... 9-75
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
XII Contents Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Contents XIII
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
XIV Contents Rexroth IndraDrive
13 Index 13-1
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-1
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-2 Basics on Device Diagnosis Rexroth IndraDrive
Priorities of Display The following priorities apply for displaying the current diagnostic
message:
8-digit display
1 E2025 warning
1 C09 command
1 AF operating status
increasing priority
Fig. 1-1: Priorities of displays (with example displays)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-3
The diagnostic message for the non-fatal error "Excessive deviation", for
example, has the following structure:
diagnostic text
diagnostic message number
The current operating mode is not shown on the display. When the drive
follows the preset operating mode and no command was activated, the
display reads "AF".
Diagnostic Messages in Plain Text
The diagnostic message in plain text contains the diagnostic message
number followed by the diagnostic text. It can be read via the S-0-0095,
Diagnostic message parameter and directly displayed on an operator
interface as a language-dependent description of the drive status.
The diagnostic message in plain text is switched to the selected language
via the S-0-0265, Language selection parameter.
Diagnostic Message Number
The diagnostic message number contains only the diagnostic number
without the diagnostic text. It can be read with the S-0-0390, Diagnostic
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-4 Basics on Device Diagnosis Rexroth IndraDrive
Language Selection
Via parameter S-0-0265, Language selection it is possible to define or
switch the language of diagnostic message texts.
Status Classes
Brief Description
The drive differentiates between 3 states (error, warning and message)
for which there is status information. To make the status information
available there are so-called status class parameters (S-0-0011,
S-0-0012, S-0-0013) that contain the respective status bits.
In addition to these status class parameters there are change bits
contained in the status word of the field bus (e.g. S-0-0135 in the case of
SERCOS) that display changes in one of the above-mentioned status
class parameters (collective information).
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-5
Functional Description
Status Class Parameters • S-0-0011, Class 1 diagnostics (status parameter for drive errors)
• In case a drive error occurs, the bit assigned to the error is set in
parameter S-0-0011. A separate bit is assigned in S-0-0011 to
errors defined according to SERCOS.
Manufacturer-specific errors cause bit 15 to be set in S-0-0011.
• In case a drive error occurs, bit 13 (drive interlock; error in class 1
diagnostics) is simultaneously set in the status word of the field bus
(S-0-0135 in the case of SERCOS).
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-6 Basics on Device Diagnosis Rexroth IndraDrive
Change Bits in Drive Status If the status of a bit in S-0-0012, Class 2 diagnostics or S-0-0013,
Word Class 3 diagnostics changes, the change bit for class 2 or 3 diagnostics
is set in the field bus status word (e.g. S-0-0135 in the case of SERCOS).
A change bit in the status word (bit 11 or 12) is always set due to a
change of the parameter content of S-0-0012 or S-0-0013. This enables
the master to recognize very quickly whether a change occurred in
S-0-0012 or S-0-0013.
A read access to one of the two parameters clears the respective change
bit again.
Masking the Change Bit By means of the parameters S-0-0097, Mask class 2 diagnostics and
S-0-0098, Mask class 3 diagnostics it is possible to mask out certain
bits in terms of their effect on the change bit of the status word (bit 12 or
bit 11).
The figure below illustrates the principle of masking by means of an
example:
unequal 0 ?
yes
Notes on Commissioning
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-7
The figure below illustrates the handling of the change bits in the status
word and of the status class parameters:
reading
S-0-0135, Drive status word
drive error
drive error ? yes
(S-0-0135; bit 13 = 1)
reading
no
S-0-0011, Class 1 diagnostics
no reading
S-0-0390, Diagn. message no.
drive warning
change bit
class 2 diagnostics? yes
(S-0-0135; bit 12 = 1)
reading
no
S-0-0012, Class 2 diagnostics
no reading
S-0-0390, Diagn. message no.
drive message
change bit
class 3 diagnostics? yes
(S-0-0135; bit 11 = 1)
no reading
S-0-0013, Class 3 diagnostics
interpreting
class diagnostics information
and starting error
clearing command, if necessary
DC0009v1.fh7
Fig. 1-5: Handling the change bits and status class parameters
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-8 Basics on Device Diagnosis Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-9
Control Parameters
Apart from the parameters for status display, there are parameters
available in the drive that are used to control the drive functions (see also
corresponding parameter description):
• P-0-0045, Control word of current controller
• P-0-0427, Control parameter of analog output
• P-0-0522, Commutation setting control word
• P-0-0556, Control word of axis controller
• P-0-0612, Control word for setting absolute measuring
• P-0-4028, Device control word
Brief Description
The standard design of IndraDrive controllers includes a control panel
with an 8-digit display and four buttons located underneath it.
The display shows operating states, command and error diagnoses, as
well as present warnings.
Using the four buttons, the commissioning engineer or service technician
can opt to display extended diagnostic messages at the drive controller
and to activate simple commands (in addition to master communication
using the commissioning tool or NC control unit).
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-10 Basics on Device Diagnosis Rexroth IndraDrive
8-digit display
1 F4002
Esc Enter
DG0001v1.fh7
Fig. 1-6: Standard control panel with display and control elements (example
of display)
Functional Description
Standard Displays The display of the IndraDrive controller automatically shows:
• status of the master communication
• operating status
• activated commands and command diagnoses
• warnings and error diagnoses
The displays have priorities because it is impossible to have various
displays at the same time.
8-digit display
1 P-1 phase -1
1 P0 phase 0
1 P1 phase 1
1 P2 phase 2
1 P3 phase 3
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-11
8-digit display
1 Ab drive ready
1 AF drive enable
1 AS drive interlock
1 AH Drive Halt
1 AE drive shutdown
1 AC drive check
8-digit display
1 C0101
number of the drive in the display of the
bus system of the master command error
communication number
display of the
currently active
command
8-digit display
1 F4002
1 E2051
number of the drive in the display of the error
bus system of the master or warning number
communication
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-12 Basics on Device Diagnosis Rexroth IndraDrive
Priorities of Display The current drive status is displayed with highest priority.
8-digit display
1 E2025 warning
1 C09 command
1 AF operating status
increasing priority
Fig. 1-11: Priority of displays with examples
Activating Extended Display and By simultaneously pressing the "Enter" and "Esc" buttons (for 8 s!) you
Command Input can call up extended displays; subsequently pressing the "Up" button
activates the command input.
2.Comand
commands/settings
"Up" button
press "Enter"
standard display and "Esc" extended display
buttons for
8 seconds
e.g.: 1 F2002 1.Er.Anz
Fig. 1-12: Activating the extended display and the command input
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-13
Extended Displays By means of the extended displays it is possible to additionally call up the
contents of certain parameters:
• error memory
• diagnostic message memory
• operating hours counter control section
• operating hours counter power section
• type designation of the firmware active in the device
• safety technology code, if safety technology option available
"Up" "Down"
button button
"Enter" button
type designation of 1.5 FWA-INDRV*-..
firmware S-0-0030 "Esc" button
"Up" "Down"
button button
"Enter" button
operating hours counter 1.4 XXXXX.XX
power section P-0-0191 "Esc" button
"Up" "Down"
button button
"Enter" button
operating hours counter 1.3 XXXXX.XX
control section P-0-0190 "Esc" button
"Up" "Down"
button button
"Enter" button
diagnostic message
1.2 0:A0002
memory S-0-0375 "Esc" button
browse list lines with "Up/Down"
buttons
"Up" "Down"
error memory button button
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-14 Basics on Device Diagnosis Rexroth IndraDrive
Command Inputs Starting from the extended display it is possible to activate commands
and make settings:
• set the drive address (drive number in the bus system of the master
communication)
• set the length of the fiber optic cable
• activate the "analog mode" master communication
• C07_x load defaults procedure command (loading controller
parameters resp. base parameters)
• other commands like
• C2200 Backup working memory procedure command
• C2300 Load working memory command
• C2500 Copy IDN from optional memory to internal memory
• C2600 Copy IDN from internal memory to optional memory
• C2900 Firmware update from MMC
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-15
...other commands...
"Up" "Down"
button button
"Enter" button
"Enter" button
"Set absolute 2.5 C03 "Esc" button 2.5 C03? C03 act.
measuring" command
autom. return
"Up" "Down"
button button
"Enter" button
"Enter" button
"Load defaults 2.4 C07 "Esc" button P-4090 0 C07_0act
procedure" command load controller
paramter values
"Up" "Down"
button button
"Enter" button
0,1*Nmax Easy-ON
9x"Up" 9x"Down"
button button
1*Nmax
"Up" automatic return
button
"Enter" button
2.2
fiber optic cable length P-0-4027 "Esc" button 0...15m
select ranges of length
with "Up/Down" buttons
accept with "Enter" button
"Up" "Down"
drive address button button
"Up" "Down"
button button
explanation: Y.Y display changes (flashes)
1.Er.Anz XXXXXXXX between "Y.Y" and "XXXXXXXX"
Fig. 1-14: Activating settings and commands that can be accessed via the
control panel
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-16 Basics on Device Diagnosis Rexroth IndraDrive
Notes on Commissioning
Note: By pressing the "Esc" button again the standard display will
reappear.
Note: The input via the buttons is polled in an 8 ms-cycle, the display
is updated in an 8 ms-cycle, too.
Error
Depending on the operating mode that is used and some parameter
settings, the drive controller carries out monitoring functions. An error
message is generated by the drive controller, if a status is detected that
no longer allows correct operation.
Error Classes Errors can be divided into several error classes. The error class is
represented by the first two digits of the diagnostic message number.
Drive Error Reaction If the drive controller is in control (drive enable was set) and an error
occurs, the drive controller automatically starts a drive error reaction.
The reaction to errors of certain classes can be influenced by the
P-0-0119, Best possible deceleration parameter.
At the end of each error reaction, the drive is torque-free.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Basics on Device Diagnosis 1-17
Clearing Errors Errors are not automatically cleared; they have to be cleared by:
• the control unit by activating the S-0-0099, C0500 Reset class 1
diagnostics command or
• by the user via the control panel
If the error status persists the drive controller generates the error
message again.
Booting and Firmware Download
Errors
Note: Apart from the mentioned error classes that can occur during
operation, errors can occur when the devices are booted and
during firmware download. These errors are not displayed at
the control panel with a diagnostic message number of the
"Fxxxx" pattern, but with a short text. Booting and firmware
download errors are described separately.
Warnings
While in operation the drive controller carries out monitoring functions.
Some monitoring functions depend on the operating mode that is used
and/or parameter settings. If a status is detected that still allows correct
operation but persists, which would then cause an error to be generated,
a warning is generated.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
1-18 Basics on Device Diagnosis Rexroth IndraDrive
Commands
Commands are used to control complex functions in the drive. The
command execution is displayed in a diagnostic message.
By means of the respective parameter that is assigned to the command, a
higher-level control unit can start, interrupt and clear commands. In
addition, some selected commands can be directly started via the control
panel of the drive controller.
There are 3 command types:
Drive Control Commands Drive control commands can only be started when drive enable was set.
They might possibly cause automatic drive motion and deactivate the
active operating mode during its execution.
Monitoring Commands Executing monitoring commands activates or deactivates monitors and
functions.
Administration Commands Administration commands execute administration tasks. They cannot be
interrupted.
States/Operating States
The diagnostic status messages display the phases of communication
build-up and initialization (boot phase), operating states or the currently
active operating mode.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Important directions for use 2-1
Introduction
Rexroth products represent state-of-the-art developments and
manufacturing. They are tested prior to delivery to ensure operating safety
and reliability.
The products may only be used in the manner that is defined as
appropriate. If they are used in an inappropriate manner, then situations
can develop that may lead to property damage or injury to personnel.
Before using Rexroth products, make sure that all the pre-requisites for
an appropriate use of the products are satisfied:
• Personnel that in any way, shape or form uses our products must first
read and understand the relevant safety instructions and be familiar
with appropriate use.
• If the product takes the form of hardware, then they must remain in
their original state, in other words, no structural changes are permitted.
It is not permitted to decompile software products or alter source
codes.
• Do not mount damaged or faulty products or use them in operation.
• Make sure that the products have been installed in the manner
described in the relevant documentation.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
2-2 Important directions for use Rexroth IndraDrive
Note: The drive controllers may only be used with the accessories
and parts specified in this document. If a component has not
been specifically named, then it may not be either mounted or
connected. The same applies to cables and lines.
Operation is only permitted in the specified configurations and
combinations of components using the software and firmware
as specified in the relevant function descriptions.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Safety Instructions for Electric Drives and Controls 3-1
3.1 Introduction
Read these instructions before the initial startup of the equipment in order
to eliminate the risk of bodily harm or material damage. Follow these
safety instructions at all times.
Do not attempt to install or start up this equipment without first reading all
documentation provided with the product. Read and understand these
safety instructions and all user documentation of the equipment prior to
working with the equipment at any time. If you do not have the user
documentation for your equipment, contact your local Bosch Rexroth
representative to send this documentation immediately to the person or
persons responsible for the safe operation of this equipment.
If the equipment is resold, rented or transferred or passed on to others,
then these safety instructions must be delivered with the equipment.
3.2 Explanations
The safety instructions describe the following degrees of hazard
seriousness in compliance with ANSI Z535. The degree of hazard
seriousness informs about the consequences resulting from non-
compliance with the safety instructions.
Warning symbol with signal Degree of hazard seriousness according
word to ANSI
DANGER
WARNING
CAUTION
Fig. 3-1: Hazard classification (according to ANSI Z535)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
3-2 Safety Instructions for Electric Drives and Controls Rexroth IndraDrive
CAUTION
CAUTION
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Safety Instructions for Electric Drives and Controls 3-3
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
3-4 Safety Instructions for Electric Drives and Controls Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Safety Instructions for Electric Drives and Controls 3-5
Touching live parts with voltages of 50 Volts and more with bare hands or
conductive tools or touching ungrounded housings can be dangerous and
cause electric shock. In order to operate electrical equipment, certain
parts must unavoidably have dangerous voltages applied to them.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
3-6 Safety Instructions for Electric Drives and Controls Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Safety Instructions for Electric Drives and Controls 3-7
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
3-8 Safety Instructions for Electric Drives and Controls Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Safety Instructions for Electric Drives and Controls 3-9
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
3-10 Safety Instructions for Electric Drives and Controls Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Safety Instructions for Electric Drives and Controls 3-11
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
3-12 Safety Instructions for Electric Drives and Controls Rexroth IndraDrive
Notes
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Diagnostic Messages when Booting the Devices 4-1
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
4-2 Diagnostic Messages when Booting the Devices Rexroth IndraDrive
PLC ?
Brief Description: PLC start dialog
Before "Boot 2.9" was displayed on the control panel the buttons "ESC"
and "ENTER" had been simultaneously pressed and kept pressed on the
control panel.
As the functional package "Motion Logic" (drive PLC and technology
functions) has been enabled, the display reads "PLC ?". The automatic
start of a PLC boot project was prevented.
By pressing the arrow buttons (arrow down or arrow up) the display
changes between "Run PLC" and "Stop PLC".
Stop PLC
Brief Description: Do not start PLC after booting
Pressing the "ENTER" button on the control panel prevents the start of a
PLC boot project.
Run PLC
Brief Description: Start PLC after booting
When the "ENTER" button is pressed on the control panel, the drive PLC
and a possibly available boot project are started after the booting process.
No IDN on MMC !
Brief Description: MMC was not formatted correctly
Cause Remedy
Content of MMC is incorrect. Parameter (*.pbf) or Switch drive off and plug in MMC with correct content
retain file (*.rbf) is missing
MMC was not formatted correctly Switch drive off and plug in appropriate MMC
– or –
Switch drive off and format MMC again on PC and plug
it in again
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Diagnostic Messages when Booting the Devices 4-3
Cause Remedy
Active, non-volatile memory (P-0-4065, Non-volatile Confirm diagnostic message with "ENTER" and start
memory active) has changed while drive was loading of new parameters
switched off, because – or –
– an MMC was plugged (before switching drive off, Switch drive off and insert active, non-volatile memory
device-internal memory had been active) or again that was used before drive was switched off, by
– MultiMediaCard (MMC) was replaced (other MMC either plugging in MMC / old MMC or removing MMC
was active) or again (device-internal memory was active). Then switch
– MMC was removed (before switching drive off, drive on again
MMC was active)
End C29
Brief Description: Command C29 successfully completed
The command C2900 Command Firmware update from MMC was
successfully completed. The firmware was copied from the
MultiMediaCard (MMC) to the drive-internal memory.
Cause Remedy
MMC was not formatted correctly Switch drive off and plug in appropriate MMC
– or –
Switch drive off and format MMC again on PC and plug
it in again
No IBF file or several IBF files on MMC Switch drive off and plug in appropriate MMC
No appropriate parameter file and retain data file on Switch drive off and plug in appropriate MMC
MMC
Cause Remedy
IBF file on MMC is not okay Switch drive off and install MMC with appropriate IBF file
in drive
– or –
On PC copy appropriate IBF file to MMC
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
4-4 Diagnostic Messages when Booting the Devices Rexroth IndraDrive
Firmware update ?
Brief Description: Different firmware in device and on MMC
During the booting process with the MMC plugged in, a check is run by
means of the release version to find out whether the firmware (FW) on
the flash is identical to the one on the MMC.
Cause Remedy
Check showed that firmware on flash and on MMC Switch drive off and install MMC in drive with the same
are not identical release version as on flash
– or –
Confirm diagnostic message with "ENTER" and start
firmware update
Update Error !
Brief Description: Firmware update error during booting process
Cause Remedy
Firmware update was not carried out correctly Reboot device and start firmware update
– or –
Switch drive off, remove MMC and carry out firmware
update on PC via auxiliary program "Dolfi"
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Operating States 5-1
5 Operating States
In the following, the possible operating states are listed in alphabetical
order. The operating states are displayed on the control panel of the
device:
Ab
"drive ready" (Antrieb bereit)
see also: A0012 Control and power sections ready for operation
AC
AE
AF
"drive enable" (Antrieb Freigabe)
Depending on the operating mode used you can find a detailed
description of the "AF" display under the respective diagnostic status
message.
AH
"Drive Halt" (Antrieb Halt)
see also: A0010 Drive HALT
AS
ASP
AU
bb
"ready for operation" (betriebsbereit)
see also: A0013 Ready for power on
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
5-2 Operating States Rexroth IndraDrive
charg
see also: A0503 DC bus charging active
LB
see also: A0500 Supply module in voltage control resp. A0503 Supply
module in operation
P0
"Phase 0" (only with SERCOS master communication)
see also: A0000 Communication phase 0
P-1
"Phase -1"
see also: A0009 Automatic baud rate detection for SERCOS Interface
P1
"Phase 1"
see also: A0001 Communication phase 1
P2
"Phase 2"
see also: A0002 Communication phase 2
P3
"Phase 3"
see also: A0003 Communication phase 3
PL
"parameter load with basic values"
see also: F2009 PL Load parameter default values
RL
see also: F2008 RL The motor type has changed
SBB
see also: A0017 Special mode motion active
SBH
see also: A0016 Safety related operational stop active
SH
see also: A0015 Safety related standstill active
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Operating States 5-3
ZKS
see also: A0520 DC bus quick discharge active
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
5-4 Operating States Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-1
A0000 - Attributes
Display: P0
Mess. no.: A0000 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-2 Status Diagnostic Messages Rexroth IndraDrive
A0001 - Attributes
Display: P1
Mess. no.: A0001 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-3
During the communication phase 2 the control panel of the drive reads
"P2".
In order to get to communication phase 2 the master, in the case of drives
with field bus and SERCOS interfaces, sets "communication phase 2" via
the master communication interface. Another possibility to switch to
communication phase 2 is to execute the P-0-4023, C0400
Communication phase 2 transition command.
Communication Phase 3 Before it is possible to switch to communication phase 3 it is necessary to
execute the S-0-0127, C0100 Communication phase 3 transition
check command. Among other things the drive, during the transition
check, checks the parameters required for communication phase 3 for
validity.
After successful execution of the transition check command the master
switches the drive to communication phase 3 (in the case of field bus and
SERCOS devices) or the drive automatically switches to phase 3 at the
end of the transition check command.
A0002 - Attributes
Display: P2
Mess. no.: A0002 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-4 Status Diagnostic Messages Rexroth IndraDrive
A0003 - Attributes
Display: P3
Mess. no.: A0003 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-5
A0009 - Attributes
Display: P -1
Mess. no.: A0009 (hex)
The Drive HALT function is activated by the master via the master
communication interface by clearing the Drive HALT bit in the S-0-0134,
Master control word parameter or by interrupting a drive control
command (e.g. Drive controlled homing procedure).
When the Drive HALT function is active the control panel of the drive
reads "AH".
The Drive HALT function is used to shut down an axis with defined
acceleration and defined jerk.
In the case of speed control and torque control the drive is shut down
by means of velocity command value reset with maximum torque.
A0010 - Attributes
Display: AH
Mess. no.: A0010 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-6 Status Diagnostic Messages Rexroth IndraDrive
A0011 - Attributes
Display: AS
Mess. no.: A0011 (hex)
For HMS, HMD, HCS The A0012 Control and power sections ready for operation diagnostic
message signals that the drive is provided with control voltage and the
power has been switched on. The drive is ready for power output.
Note: This status is displayed on the control panel of the drive with
"Ab" ("Antrieb bereit" = Drive ready).
For HMV The diagnostic message A0012 Control and power sections ready for
operation signals that the supply unit is ready for switching in the mains
contactor.
Note: This status is displayed on the control panel of the device with
"Bb" ("betriebsbereit" = ready for operation).
A0012 - Attributes
Display: Ab
Mess. no.: A0012 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-7
The A0013 Ready for power on diagnostic message signals that the
drive is provided with control voltage and that there isn’t any error present
in the drive.
The drive is ready for power on.
Note: This status is displayed on the control panel of the drive with
"bb" ("betriebsbereit" = ready for operation).
A0013 - Attributes
Display: bb
Mess. no.: A0013 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-8 Status Diagnostic Messages Rexroth IndraDrive
The drive is in the "special mode standstill". The active safety function is
"safety related drive interlock".
The drive has come to standstill, the power supply has been interrupted
via two channels (output stage locked).
A0014 - Attributes
Display: ASP
Mess. no.: A0014 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-9
The drive is in the "special mode standstill". The active safety function is
"safety related standstill".
The drive has come to standstill, the power supply has been interrupted
via two channels (output stage locked).
If the drive is still in motion when "safety related standstill" is selected,
there first is a stopping process, then the power supply is interrupted via
two channels (output stage locked).
A0015 - Attributes
Display: SH
Mess. no.: A0015 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-10 Status Diagnostic Messages Rexroth IndraDrive
The drive is in the "special mode standstill". The active safety function is
"safety related operational stop".
The drive has come to standstill, the power supply has not been
interrupted, all control loops are active, the standstill monitors are active.
If the drive is still in motion when "safety related operational stop" is
selected, there first is a stopping process, then the standstill monitors
become active (axis/spindle cannot be moved). When the drive leaves the
standstill position, the output stage is locked via two channels.
A0016 - Attributes
Display: SBH
Mess. no.: A0016 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-11
Note: The "special mode motion" can only be selected for the time
limited by P-0-3222, Max. activation time of enabling
control.
According to selection, bit 3, 4, 5 or 6 is set in parameter
P-0-3213, Safety technology status.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-12 Status Diagnostic Messages Rexroth IndraDrive
Safety Related Homing Even if an absolute measuring system is used, it is necessary to carry out
Procedure the homing procedure for safely determining the "reference position
channel 2". The "reference position channel 2" is determined via
cam/switch at a separate input on channel 2.
A0017 - Attributes
Display: SBB
Mess. no.: A0017 (hex)
The drive is in the "Torque control" mode. It follows the torque command
value characteristic set by the master.
A0100 - Attributes
Display: AF
Mess. no.: A0100 (hex)
The drive is in the "Velocity control" mode. It follows the speed command
value characteristic set by the master. The speed control loop is closed in
the drive.
A0101 - Attributes
Display: AF
Mess. no.: A0101 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-13
A0102 - Attributes
Display: AF
Mess. no.: A0102 (hex)
A0103 - Attributes
Display: AF
Mess. no.: A0103 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-14 Status Diagnostic Messages Rexroth IndraDrive
A0104 - Attributes
Display: AF
Mess. no.: A0104 (hex)
A0105 - Attributes
Display: AF
Mess. no.: A0105 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-15
From the control unit the drive receives a position command value
identical to the target position of the distance to be traveled. The drive
then generates (interpolates) an internal position command value
characteristic that complies with the maximum values for the jerk,
acceleration and velocity characteristic determined by the master.
With a lag error the drive moves to the target position.
"Encoder 1" means that the encoder assigned by means of P-0-0077,
Assignment motor encoder->optional slot is used as a control
encoder.
A0106 - Attributes
Display: AF
Mess. no.: A0106 (hex)
From the master the drive receives a position command value identical to
the target position of the distance to be traveled. The drive then generates
(interpolates) an internal position command value characteristic that
complies with the maximum values for the jerk, acceleration and velocity
characteristic determined by the master.
With a lag error the drive moves to the target position.
"Encoder 2" means that the encoder assigned by means of P-0-0078,
Assignment optional encoder->optional slot is used as a control
encoder.
A0107 - Attributes
Display: AF
Mess. no.: A0107 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-16 Status Diagnostic Messages Rexroth IndraDrive
From the master the drive receives a position command value identical to
the target position of the distance to be traveled. The drive then generates
(interpolates) an internal position command value characteristic that
complies with the maximum values for the jerk, acceleration and velocity
characteristic determined by the master.
The drive laglessly moves to the target position (prerequisite: P-0-0040,
Velocity feedforward evaluation=100%).
"Encoder 1" means that the encoder assigned by means of P-0-0077,
Assignment motor encoder->optional slot is used as a control
encoder.
A0108 - Attributes
Display: AF
Mess. no.: A0108 (hex)
From the master the drive receives a position command value identical to
the target position of the distance to be traveled. The drive then generates
(interpolates) an internal position command value characteristic that
complies with the maximum values for the jerk, acceleration and velocity
characteristic determined by the master.
The drive laglessly moves to the target position (prerequisite: P-0-0040,
Velocity feedforward evaluation=100%).
"Encoder 2" means that the encoder assigned by means of P-0-0078,
Assignment optional encoder->optional slot is used as a control
encoder.
A0109 - Attributes
Display: AF
Mess. no.: A0109 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-17
The drive is in velocity control. Taking the gear ratio and the master axis
position into account, the command speed is determined in the drive.
Virtual master axis means that the master axis position is calculated by
the control unit.
A0110 - Attributes
Display: AF
Mess. no.: A0110 (hex)
The drive is in velocity control. The speed command value is derived from
the master axis position. The master axis position is generated by the
measuring encoder.
A0111 - Attributes
Display: AF
Mess. no.: A0111 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-18 Status Diagnostic Messages Rexroth IndraDrive
A0112 - Attributes
Display: AF
Mess. no.: A0112 (hex)
A0113 - Attributes
Display: AF
Mess. no.: A0113 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-19
A0114 - Attributes
Display: AF
Mess. no.: A0114 (hex)
A0115 - Attributes
Display: AF
Mess. no.: A0115 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-20 Status Diagnostic Messages Rexroth IndraDrive
A0116 - Attributes
Display: AF
Mess. no.: A0116 (hex)
A0117 - Attributes
Display: AF
Mess. no.: A0117 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-21
A0118 - Attributes
Display: AF
Mess. no.: A0118 (hex)
A0119 - Attributes
Display: AF
Mess. no.: A0119 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-22 Status Diagnostic Messages Rexroth IndraDrive
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value with a lag distance.
Encoder 1 means that the position encoder is mounted to the motor shaft
(indirect measuring of the axis position). Virtual master axis means that
the master axis position is calculated by the control unit.
A0128 - Attributes
Display: AF
Mess. no.: A0128 (hex)
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value with a lag distance.
Encoder 2 means that the position encoder is mounted to the machine
axis (direct measuring of the axis position). Virtual master axis means that
the master axis position is calculated by the control unit.
A0129 - Attributes
Display: AF
Mess. no.: A0129 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-23
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value with a lag distance.
Encoder 1 means that the position encoder is mounted to the motor shaft
(indirect measuring of the axis position). Real master axis means that the
master axis position is derived from the measuring encoder.
A0130 - Attributes
Display: AF
Mess. no.: A0130 (hex)
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value with a lag distance.
Encoder 2 means that the position encoder is mounted to the machine
axis (direct measuring of the axis position). Real master axis means that
the master axis position is derived from the measuring encoder.
A0131 - Attributes
Display: AF
Mess. no.: A0131 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-24 Status Diagnostic Messages Rexroth IndraDrive
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value without any lag error.
Encoder 1 means that the position encoder is mounted to the motor shaft
(indirect measuring of the axis position). Virtual master axis means that
the master axis position is calculated by the control unit.
A0132 - Attributes
Display: AF
Mess. no.: A0132 (hex)
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value without any lag error.
Encoder 2 means that the position encoder is mounted to the machine
axis (direct measuring of the axis position). Virtual master axis means that
the master axis position is calculated by the control unit.
A0133 - Attributes
Display: AF
Mess. no.: A0133 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-25
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value without any lag error.
Encoder 1 means that the position encoder is mounted to the motor shaft
(indirect measuring of the axis position). Real master axis means that the
master axis position is derived from the incremental encoder signals.
A0134 - Attributes
Display: AF
Mess. no.: A0134 (hex)
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value without any lag error.
Encoder 2 means that the position encoder is mounted to the machine
axis (direct measuring of the axis position). Real master axis means that
the master axis position is derived from the measuring encoder.
A0135 - Attributes
Display: AF
Mess. no.: A0135 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-26 Status Diagnostic Messages Rexroth IndraDrive
From the master the drive receives a position command value in the
S-0-0282, Positioning command value parameter. This
position/distance, when the status of bit 0 of parameter S-0-0346,
Positioning command strobe changes, is copied to S-0-0258, Target
position or, in the case of a relative input, added to the value in
S-0-0430, Effective target position. The drive then generates
(interpolates) an internal position command value characteristic in order
to get from the current position to this target position. This is done
considering the limit values for velocity, acceleration and jerk in the
following parameters:
• S-0-0193, Positioning Jerk,
• S-0-0259, Positioning Velocity,
• S-0-0260, Positioning Acceleration and
• S-0-0359, Positioning Deceleration.
With a lag error proportional to the velocity the drive moves to the target
position.
"Encoder 1" means that the encoder assigned by means of P-0-0077,
Assignment motor encoder->optional slot is used as a control
encoder.
A0150 - Attributes
Display: AF
Mess. no.: A0150 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-27
From the master the drive receives a position command value in the
S-0-0282, Positioning command value parameter. This distance, when
the status of bit 0 of parameter S-0-0346, Positioning command strobe
changes, is copied to S-0-0430, Effective target position or, in the case
of a relative input, added to the value in S-0-0430, Effective target
position. The drive then generates (interpolates) an internal position
command value characteristic in order to get from the current position to
this target position. This is done considering the limit values for velocity,
acceleration and jerk in the following parameters:
• S-0-0259, Positioning Velocity,
• S-0-0260, Positioning Acceleration,
• S-0-0359, Positioning Deceleration and
• S-0-0193, Positioning Jerk.
The drive laglessly moves to the target position (prerequisite: P-0-0040,
Velocity feedforward evaluation=100%).
"Encoder 1" means that the encoder assigned by means of P-0-0077,
Assignment motor encoder->optional slot is used as a control
encoder.
A0151 - Attributes
Display: AF
Mess. no.: A0151 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-28 Status Diagnostic Messages Rexroth IndraDrive
From the master the drive receives a position command value in the
S-0-0282, Positioning command value parameter. This distance, when
the status of bit 0 of parameter S-0-0346, Positioning command strobe
changes, is copied to S-0-0430, Effective target position or, in the case
of a relative input, added to the value in S-0-0430, Effective target
position. The drive then generates (interpolates) an internal position
command value characteristic in order to get from the current position to
this target position. This is done considering the limit values for velocity,
acceleration and jerk in the following parameters:
• S-0-0259, Positioning Velocity,
• S-0-0260, Positioning Acceleration,
• S-0-0359, Positioning Deceleration and
• S-0-0193, Positioning Jerk.
With a lag error proportional to the velocity the drive moves to the target
position.
"Encoder 2" means that the encoder assigned by means of P-0-0078,
Assignment optional encoder->optional slot is used as a control
encoder.
A0152 - Attributes
Display: AF
Mess. no.: A0152 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-29
From the master the drive receives a position command value in the
S-0-0282, Positioning command value parameter. This distance, when
the status of bit 0 of parameter S-0-0346, Positioning command strobe
changes, is copied to S-0-0430, Effective target position or, in the case
of a relative input, added to the value in S-0-0430, Effective target
position. The drive then generates (interpolates) an internal position
command value characteristic in order to get from the current position to
this target position. This is done considering the limit values for velocity,
acceleration and jerk in the following parameters:
• S-0-0259, Positioning Velocity,
• S-0-0260, Positioning Acceleration,
• S-0-0359, Positioning Deceleration and
• S-0-0193, Positioning Jerk.
The drive laglessly moves to the target position (prerequisite: P-0-0040,
Velocity feedforward evaluation=100%).
"Encoder 2" means that the encoder assigned by means of P-0-0078,
Assignment optional encoder->optional slot is used as a control
encoder.
A0153 - Attributes
Display: AF
Mess. no.: A0153 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-30 Status Diagnostic Messages Rexroth IndraDrive
A0154 - Attributes
Display: AF
Mess. no.: A0154 (hex)
A0155 - Attributes
Display: AF
Mess. no.: A0155 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-31
A0156 - Attributes
Display: AF
Mess. no.: A0156 (hex)
A0157 - Attributes
Display: AF
Mess. no.: A0157 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-32 Status Diagnostic Messages Rexroth IndraDrive
A0206 - Attributes
Display: AF
Mess. no.: A0206 (hex)
A0207 - Attributes
Display: AF
Mess. no.: A0207 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-33
A0210 - Attributes
Display: AF
Mess. no.: A0210 (hex)
A0211 - Attributes
Display: AF
Mess. no.: A0211 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-34 Status Diagnostic Messages Rexroth IndraDrive
The mains contactor has been switched in, the DC bus has been
charged, the DC bus voltage is regulated to 750 V direct voltage.
A0500 - Attributes
Display: Lb
Mess. no.: A0500 (hex)
The mains contactor has been switched in, the DC bus has been
charged, the DC bus current is regulated with regard to a preset
command value.
A0501 - Attributes
Display: I Lb
Mess. no.: A0501 (hex)
The mains contactor has been switched in, the DC bus has been charged
and is ready for power output.
A0502 - Attributes
Display: Lb
Mess. no.: A0502 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-35
The DC bus is presently charged to the crest value of the mains voltage
("soft start"). When the voltage in the DC bus has reached the crest value
of the mains voltage, the mains contactor is switched in.
A0503 - Attributes
Display: charg
Mess. no.: A0503 (hex)
The mains contactor has been switched in, the DC bus is regulated to
65 V. All monitoring thresholds have been adjusted for a test run at 43 V
mains voltage.
A0510 - Attributes
Display: lb
Mess. no.: A0510 (hex)
The mains contactor has been switched in, the DC bus current is
regulated with regard to a preset command value. All monitoring
thresholds have been adjusted for a test run at 43 V mains voltage.
A0511 - Attributes
Display: i lb
Mess. no.: A0511 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-36 Status Diagnostic Messages Rexroth IndraDrive
The mains contactor has been switched in. DC bus voltage is available.
All monitoring thresholds have been adjusted for a test run at 43 V mains
voltage.
A0512 - Attributes
Display: lb
Mess. no.: A0512 (hex)
Note: The "DC bus short circuit" function (ZKS) was activated via the
terminal strip X32 at the HMV.
A0520 - Attributes
Display: ZKS
Mess. no.: A0520 (hex)
There isn’t any diagnostic message existing for the activated operating
mode.
A0800 - Attributes
Display: AF
Mess. no.: A0800 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Status Diagnostic Messages 6-37
A4000 - Attributes
Display: AC
Mess. no.: A4000 (hex)
The drive
• is decelerated to standstill as set in the P-0-0119, Best possible
deceleration parameter
- or -
Note: This status is displayed on the control panel of the drive with
"AE".
A4001 - Attributes
Display: AE
Mess. no.: A4001 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
6-38 Status Diagnostic Messages Rexroth IndraDrive
A4002 - Attributes
Display: AU
Mess. no.: A4002 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-1
7 Error Messages
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-2 Error Messages Rexroth IndraDrive
Cause:
An error occurred in the firmware (general software error). The drive was
switched off by the firmware.
Remedy:
Please contact our service department.
E0000 - Attributes
Display: E-XXXX
Mess. no.: E0000 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-3
Cause Remedy
Undefined cause Switch device off/on. If error persists, replace device
An error occurred in firmware (general software Please contact our service department
error)
F9001 - Attributes
Display: F9001
Mess. no.: F9001 (hex)
Cause:
An error occurred in the firmware (general software error). The drive was
switched off by the firmware.
Remedy:
Please contact our service department.
F9002 - Attributes
Display: F9002
Mess. no.: F9002 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-4 Error Messages Rexroth IndraDrive
F9003 Watchdog
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Supported by Supply Unit: HMV01
Cause Remedy
Firmware-side watchdog timer was triggered Replace device, contact our service department
(general firmware error). Drive was switched off by
firmware.
F9003 - Attributes
Display: F9003
Mess. no.: F9003 (hex)
An internal firmware error has occurred. The device was switched off by
the firmware.
Cause Remedy
An error occurred in firmware Please contact our service department
F9004 - Attributes
Display: F9004
Mess. no.: F9004 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-5
Drive Behavior In the case of fatal errors, closed-loop control (or open-loop U/f control) of
the drive is no longer ensured; with these errors the drive, independent of
the setting in P-0-0119, Best possible deceleration and P-0-0117,
Activation of NC reaction on error, therefore is immediately switched
off, i.e. it goes torque-free (see also Functional Description "Error
Reaction").
Steps of Commissioning After a fatal error has occurred, the drive can only be commissioned again
when:
1. the error message was cleared by the error clearing command (cf.
S-0-0099, C0500 Reset class 1 diagnostics) [to do this it might
possibly be necessary to switch to the parameter mode or switch the
drive off completely].
2. the actual cause of the error was recognized and removed. This
might possibly imply the replacement of an entire component (e.g.
motor or drive controller).
3. the drive is in the operating mode again and power was switched on
again ("Ab").
4. drive enable was switched on again (0-1 edge).
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-6 Error Messages Rexroth IndraDrive
Cause Remedy
Positive feedback of motor; commutation offset Check motor encoder signals. To do this move motor
determination generated incorrect value for knowing manufacturer-side setting for sense of rotation
P-0-0521, Effective commutation offset or velocity polarity and check actual position values with
regard to polarity and plausibility.
If necessary, invert polarity of motor encoder or invert
two motor phases. Carry out commutation setting again
Positive feedback of motor after axis was mounted, Check whether direction of motion (sense of rotation) of
in spite of successful initial commissioning before motor complies with that of motor encoder. If not, invert
axis was dismounted direction of motion of motor (invert phases) or of motor
encoder
During commutation setting process, axis got into Set "search direction for sine-wave method" to "increase
resonance of frequency with priority" in P-0-0522, Control word for
commutation setting
- or -
Reduce value in P-0-0507, Test frequency for angle
acquisition in order modify excitation frequency for
sine-wave method compared to resonance frequency of
axis
F8010 - Attributes
Display: F8010
Mess. no.: F8010 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-7
The sine-wave method for commutation setting could not determine any
value for the commutation offset.
Cause Remedy
Axis could not carry out required motion Check axis for stiffness or blocking; if necessary, reduce
friction (lubrication, guiding device of trailing cable
installation) or remove blocking
- or -
Set "search direction for sine-wave method" to "increase
of amplitude with priority" in P-0-0522, Control word for
commutation setting
- or -
Increase value in P-0-0506, Amplitude for angle
acquisition, in order to increase excitation amplitude for
sine-wave method compared to frictional force of axis
During commutation setting process, axis got into Set "search direction for sine-wave method" to "increase
resonance of frequency with priority" in P-0-0522, Control word for
commutation setting
- or -
Reduce value in P-0-0507, Test frequency for angle
acquisition in order modify excitation frequency for
sine-wave method compared to resonance frequency of
axis
Motor has not been supplied with current Check motor connection
Sine-wave method without success, although axis Try with manually input values if automatic search for
has required freedom of motion and doesn’t show motor-specific values for P-0-0506, Amplitude for
any resonance phenomena angle acquisition and P-0-0507, Test frequency for
angle acquisition doesn’t provide any result in spite of
several repetitions
Signals of motor encoder do not reflect motion Check motor encoder signals. To do this move motor
process of axis; encoder cables of 2 drives possibly knowing manufacturer-side setting for sense of rotation
mixed up or velocity polarity and check actual position values with
- or - regard to polarity and plausibility.
Incorrect polarity of encoder signals
F8011 - Attributes
Display: F8011
Mess. no.: F8011 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-8 Error Messages Rexroth IndraDrive
During commutation setting (sine-wave method) the axis left the allowed
actual position value range.
Cause Remedy
Heavy axis motion due to too high drive torque or Reduce value contained in P-0-0506, Amplitude for
force generation during commutation setting angle acquisition
- and / or -
Increase value contained in P-0-0507, Test frequency
for angle acquisition
External forces or torques cause axis to move out of Check mechanical axis system for occurrence of
allowed actual position value range external forces, e.g. due to trailing cable installation,
vertical load etc.
Detent force or torque causes axis to move out of Make sure that, during commutation setting by means of
allowed actual position value range sine-wave method, detent forces of motor do not cause
position limits to be exceeded near limits of actual
position value range
F8012 - Attributes
Display: F8012
Mess. no.: F8012 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-9
Cause Remedy
Actual current value amplitude is not sufficient for Increase signal voltage (P-0-0506, Amplitude for angle
exact determination of commutation offset acquisition) or reduce signal frequency (P-0-0507, Test
frequency for angle acquisition) and restart
commutation setting process
- or -
Enter value "0" in P-0-0506, Amplitude for angle
acquisition. Appropriate value for P-0-0506 is thereby
automatically determined during commutation setting
process
- or -
Reduce value of P-0-0517, Commutation: required
harmonics component, if approx. 30 similar values are
determined for P-0-0521, Effective commutation
offset with repeated commutation setting for different
motor positions (drive remains in "Ab"). Reduce
P-0-0517, Commutation: required harmonics
component until command error F8013 no longer
occurs; finally check function several times!
F8013 - Attributes
Display: F8013
Mess. no.: F8013 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-10 Error Messages Rexroth IndraDrive
Cause Remedy
Amplitude of actual current value is higher than Reduce signal voltage (P-0-0506, Voltage amplitude
allowed maximum current for angle acquisition) or increase signal frequency
(P-0-0507, Test frequency for angle acquisition)
- or -
With P-0-0506, Voltage amplitude for angle
acquisition=0 start automatic determination of
appropriate values
F8014 - Attributes
Display: F8014
Mess. no.: F8014 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-11
Saturation Method During the execution of the automatic commutation offset determination
(after drive enable) an error was detected.
Cause Remedy
An error occurred in internal signal generator used Switch the drive off and on again. If the error continues
for determining commutation offset to be signaled, contact our service department.
Sine-Wave Method The commutation setting with motion by means of the sine-wave method
is completed when the axis, after commutation offset determination, has
been moved back to the initial position at which it was before the start. If
this is impossible, the error F8015 is generated.
Cause Remedy
Axis cannot be moved back to position at which it Check mechanical axis system, remove blocking or
was at beginning of commutation determination stiffness
F8015 - Attributes
Display: F8015
Mess. no.: F8015 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-12 Error Messages Rexroth IndraDrive
Cause Remedy
Current generated during automatic commutation Check whether controller can supply motor with
offset determination could not produce any sufficiently high current (cf. S-0-0111, Motor current at
saturation effect in motor. standstill and S-0-0110, Amplifier peak current). If
Required maximum current is approx. 1.5-fold maximum controller current is too low, drive controller
continuous current at standstill (S-0-0111, Motor has to be replaced by a bigger one
current at standstill). - or -
Change position of movable part of motor with regard to
its rigid part restart command P-0-0524, C1200
Commutation offset setting command
- or -
Contact our service department and, if necessary, use
an absolute measuring system, because motor
characteristics do not allow automatic commutation
F8016 - Attributes
Display: F8016
Mess. no.: F8016 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-13
Cause Remedy
Defective encoder cable or cable shielding Check cable to measuring system and replace it, if
necessary
Measuring system defective Check measuring system and replace it, if necessary
Faulty mounting of measuring head in the case of Check mounting of measuring head and correct it, if
linear measuring systems necessary
Measuring system dirty Clean or replace measuring system
Hardware defect on control section of drive Replace control section or entire drive controller
F8022 - Attributes
Display: F8022
Mess. no.: F8022 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-14 Error Messages Rexroth IndraDrive
Cause Remedy
Mechanical connection between rotor of motor and Check connection and fix or repair it
motor encoder is loose or broken
Phase break in motor feed wire - Check motor feed wire for continuity. Take possible
"loose contacts" into account.
- Check connection of motor feed wire at controller.
- Check connection of motor feed wire at motor.
- Line break in motor. Replace motor.
- Line break in controller. Replace controller.
F8023 - Attributes
Display: F8023
Mess. no.: F8023 (hex)
In the drive a monitoring function ensures that the starting lockout cannot
be set with control being active.
Note: When the error occurs, the drive immediately becomes torque-
free!
Cause Remedy
Starting lockout was activated with drive enable Check control and connection of starting lockout input
having been set
F8027 - Attributes
Display: F8027
Mess. no.: F8027 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-15
Cause Remedy
Power demanded by drives is too high Use drives with lower peak current
Power demanded by drives is too high Reduce allowed acceleration of axis or reduce final
velocity to which acceleration takes place
F8057 - Attributes
Display: F8057
Mess. no.: F8057 (hex)
The current in the power transistors has exceeded the maximum allowed
device peak current (cf. S-0-0110, Amplifier peak current).
Cause Remedy
Short circuit in motor or motor cable Check motor cable and motor for short circuit
Power section of drive controller is defective Replace drive controller
Current loop parameterized differently Check current loop parameterization (cf. motor data
sheet) and correct it if necessary after having contacted
our service department
F8060 - Attributes
Display: F8060
Mess. no.: F8060 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-16 Error Messages Rexroth IndraDrive
An error has occurred in the internal ±15 V supply of the supply unit.
Cause Remedy
Supply unit defective Replace supply unit
F8069 - Attributes
Display: F8069
Mess. no.: F8069 (hex)
Note: When the error F8070 occurs, the motors within the drive
system are immediately go torque-free. Apply possibly existing
self-holding motor holding brakes.
Cause Remedy
Supply cable for control voltages defective Check and, if necessary, replace supply cable for
control voltages and connector
Overload of 24 V power supply unit Check 24 V supply voltage at power supply unit
Power supply unit defective Check and, if necessary, replace power supply unit
Short circuit in 24 V supply wiring Check 24 V supply wiring for short circuit
F8070 - Attributes
Display: F8070
Mess. no.: F8070 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-17
Cause Remedy
Motor phases (U, V, W) interchanged so that Check motor cable connection and correct phase
commutation of motor is incorrect assignment, if necessary
Incorrect encoder arrangement Correct encoder arrangement (inverting rotational
direction of encoder can possibly resolve problem)
Speed loop setting incorrect Check speed loop setting according to Application
Manual
Commutation offset incorrect Replace motor (in the case of MHD, MKD, MKE motors);
in the case of kit motors, make commutation settings
Motor encoder defective Replace motor encoder (or motor)
F8078 - Attributes
Display: F8078
Mess. no.: F8078 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-18 Error Messages Rexroth IndraDrive
Cause Remedy
S-0-0040, Velocity feedback value has exceeded Check and, if necessary, correct parameterization of
1.125-fold value of S-0-0091, Bipolar velocity limit S-0-0091, Bipolar velocity limit value
value
Velocity control loop instable or too heavily Check and, if necessary, correct parameterization of
oscillating due to incorrect parameterization velocity loop
Preset velocity command value too high (cf. Reduce P-0-0048, Effective velocity command value
P-0-0048 = S-0-0036, Velocity command by adjusting S-0-0036, Velocity command value or
value + S-0-0037, Additive velocity command S-0-0037, Additive velocity command value
value)
F8079 - Attributes
Display: F8079
Mess. no.: F8079 (hex)
Cause Remedy
After control voltage had been switched on, an error Replace power section or entire drive controller
was detected in power section of drive controller
F8091 - Attributes
Display: F8091
Mess. no.: F8091 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-19
During the initialization of the drive the control section is checked for
correct function. An error was detected during this check.
Cause Remedy
Control section configuration not allowed because an Switch drive off and on again. If error occurs again,
optional module (e.g. optional module 1...4, master replace control section (e.g. CSH01.1 or CDB01.1) by
communication,...) is not supported by firmware different control section with appropriate configuration.
If necessary, contact our service department
Firmware used is not suitable (e.g. MPH02VRS for Select suitable firmware by means of Functional
double-axis control section), i.e. hardware and Description or Version Notes/Release Notes
software do not match (see "supported control section configurations")
Hardware defect on control section Switch drive off and on again. If error still occurs,
contact our service department and, if necessary,
replace control section or entire drive controller
F8100 - Attributes
Display: F8100
Mess. no.: F8100 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-20 Error Messages Rexroth IndraDrive
During the initialization of the drive the power section is checked for
correct function. An error was detected during this check.
Cause Remedy
Hardware and firmware do not match Check Firmware Release Notes or Firmware Version
Notes and, if necessary, use latest firmware release
Parameter P-0-1510, Circuit board code power Switch drive off and on again. If error occurs again,
section stored on power section is invalid or was check content of P-0-1510, Circuit board code power
incorrectly written section and contact our service department!
Maybe you have to replace power section or entire drive
controller
Hardware defect on power section Replace power section or entire drive controller
F8102 - Attributes
Display: F8102
Mess. no.: F8102 (hex)
Cause Remedy
Inappropriate firmware Use firmware that matches power section
Inappropriate power section Use power section that matches firmware
F8118 - Attributes
Display: F8118
Mess. no.: F8118 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-21
Cause Remedy
Inappropriate firmware Use firmware that matches control section
Inappropriate control section Use control section that matches firmware
F8120 - Attributes
Display: F8120
Mess. no.: F8120 (hex)
Cause Remedy
Hardware of control section is defective Replace control section or entire drive controller; use
hardware configuration of same type
F8122 - Attributes
Display: F8122
Mess. no.: F8122 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-22 Error Messages Rexroth IndraDrive
Cause Remedy
Programming of firmware for optional safety Make firmware update
technology module is invalid
An error occurred during firmware update Restart firmware update.
If error message is displayed again, replace control
section with control section of same type, if you are
authorized to do this! Otherwise entire drive controller
has to be replaced.
F8129 - Attributes
Display: F8129
Mess. no.: F8129 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-23
Cause Remedy
Programming of firmware for optional safety Make firmware update
technology module is invalid
An error occurred during firmware update Restart firmware update.
If error message is displayed again, replace control
section with control section of same type, if you are
authorized to do this! Otherwise entire drive controller
has to be replaced.
F8130 - Attributes
Display: F8130
Mess. no.: F8130 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-24 Error Messages Rexroth IndraDrive
In order to lock the output stage in a safety related way when the safety
technology has detected an error, the correct functioning of the
interrupting circuit is cyclically checked. This is done on the one hand
during the actions "release output stage" and "lock output stage", on the
other hand statically while the output stage is being released or locked.
The corresponding hardware realization ensures that this is possible
without repercussion on the PWM control signals.
The drive torque is immediately disabled. The drive automatically
switches to "safety related standstill" and the output stage is switched off
via one channel. All poles of the mains contactor are switched off.
Cause Remedy
An error was detected during check of interrupting Error cannot be cleared. Switch power supply off and on
circuit again.
If error occurs repeatedly, replace control section or
entire drive controller
F8133 - Attributes
Display: F8133
Mess. no.: F8133 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-25
In the booting phase of the drive a basic initialization is carried out on both
safety technology channels. The initialization sequence on channel 2 is
started via an internal command.
Cause Remedy
Basic initialization on channel 2 is incorrect or Carry out load defaults procedure for safety technology
internal command was aborted with timeout (S-0-0262, C07_x Load defaults procedure command
with P-0-4090, Index for C07 Load defaults procedure
= 165) and reset module (switch control voltage off and
on again).
Note:
If necessary, repeat procedure if P-0-3207, Safety
technology password level is unequal 1.
Incompatible firmware releases on channel 1 and Establish compatible firmware releases on channel 1
channel 2 and channel 2
F8201 - Attributes
Display: F8201
Mess. no.: F8201 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-26 Error Messages Rexroth IndraDrive
The comparison showed that not all of the double elements are identical.
Cause Remedy
A memory cell was overwritten by mistake Command C07_2 Load def. proc. com. (load def. pr.
for safety techn.) and reset optional safety technology
module (switch control voltage off and then on again)
Note: The command C07_2 Load def. proc. com.
(load def. pr. for safety techn.) overwrites user-defined
safety technology settings! Only use this command if
you want to commission safety technology again
Firmware defect on optional safety technology If command error occurs repeatedly, safety technology
module firmware has to be replaced
Hardware defect on optional safety technology If command error occurs repeatedly, optional safety
module technology module has to be replaced
Note: The command C07_2 Load def. proc. com. (load def. pr. for
safety techn.) is started by parameter S-0-0262, C07_x Load
defaults procedure command with the respective setting in
P-0-4090, Index for C07 Load defaults procedure.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-27
F8203 - Attributes
Display: F8203
Mess. no.: F8203 (hex)
During the loading of the DC bus before switching on the power supply
("soft start") the expected DC bus voltage could not be reached within a
time window.
Cause Remedy
Too many additional capacitances were connected Reduce number of additional capacitance modules
There is short circuit or load of low impedance in DC Check wiring of DC bus connection
bus
F8806 - Attributes
Display: F8806
Mess. no.: F8806 (hex)
After the power supply had been switched on a wiring error of the mains
choke (e.g. incorrect phase sequence of the mains phases) was detected.
Cause Remedy
Mains choke was incorrectly connected Check and correct connection of mains choke
F8813 - Attributes
Display: F8813
Mess. no.: F8813 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-28 Error Messages Rexroth IndraDrive
The error F8838 is generated when the current in the braking resistor
circuit is rising in an inadmissible way.
Cause Remedy
Resistance value of connected braking resistor is too Connect braking resistor unit with higher resistance
low value (take specification into account!)
Short circuit at braking resistor connection Remove short circuit
F8838 - Attributes
Display: F8838
Mess. no.: F8838 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-29
At the end of the error reaction the drive goes torque-free and the output
stage is locked via two channels after the time entered in P-0-3220,
Tolerance time transition from normal operation or P-0-3225,
Tolerance time transition from safety rel. oper. is over.
Then the power is switched off depending on the setting in P-0-0118,
Power supply, configuration.
The drive can only be commissioned again when:
Steps of Commissioning 1. the error message was cleared by the error clearing command (cf.
S-0-0099, C0500 Reset class 1 diagnostics).
2. the actual cause of the error was recognized and removed (e.g.
incorrect parameterization of velocity thresholds or time windows).
3. the drive is in the operating mode again and power was switched on
again ("Ab").
4. drive enable was switched on again (0-1 edge).
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-30 Error Messages Rexroth IndraDrive
Remedy:
Start command S-0-0099, C0500 Reset class 1 diagnostics in order to
clear error and then set drive enable again.
F7010 - Attributes
Display: F7010
Mess. no.: F7010 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-31
Remedy:
Start command S-0-0099, C0500 Reset class 1 diagnostics in order to
clear error and then set drive enable again.
F7011 - Attributes
Display: F7011
Mess. no.: F7011 (hex)
Remedy:
Start command S-0-0099, C0500 Reset class 1 diagnostics in order to
clear error and then set drive enable again.
F7012 - Attributes
Display: F7012
Mess. no.: F7012 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-32 Error Messages Rexroth IndraDrive
Remedy:
Start command S-0-0099, C0500 Reset class 1 diagnostics in order to
clear error and then set drive enable again.
F7013 - Attributes
Display: F7013
Mess. no.: F7013 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-33
Remedy:
Start command S-0-0099, C0500 Reset class 1 diagnostics in order to
clear error and then set drive enable again.
F7014 - Attributes
Display: F7014
Mess. no.: F7014 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-34 Error Messages Rexroth IndraDrive
Cause Remedy
Velocity threshold parameterized in P-0-3234, Start command S-0-0099, C0500 Reset class 1
Safety related maximum velocity has been diagnostics in order to clear error and then set drive
exceeded enable again
F7020 - Attributes
Display: F7020
Mess. no.: F7020 (hex)
Cause Remedy
Position parameterized in P-0-3235, Safety related Start command S-0-0099, C0500 Reset class 1
end position, positive or P-0-3236, Safety related diagnostics in order to clear error and then set drive
end position, negative has been exceeded enable again
F7021 - Attributes
Display: F7021
Mess. no.: F7021 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-35
Cause Remedy
In safety function "safety related operational stop", Start command S-0-0099, C0500 Reset class 1
position window defined in P-0-3230, Monitoring diagnostics in order to clear error and then set drive
window for safety related operational stop has enable again.
been exceeded If necessary, change parameterization of P-0-3230,
Monitoring window for safety related operational
stop in useful way
F7030 - Attributes
Display: F7030
Mess. no.: F7030 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-36 Error Messages Rexroth IndraDrive
Remedy:
If necessary, change parameterization of P-0-3232, Monitoring window
for safety related direction of motion in useful way.
Start command S-0-0099, C0500 Reset class 1 diagnostics in order to
clear error and then set drive enable again.
F7031 - Attributes
Display: F7031
Mess. no.: F7031 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-37
Cause Remedy
In corresponding monitoring function a check is run Execute P-0-3204, Synchronize and store safety
to find out whether both channels are working with technology IDN command (channel 2 accepts
the same internal safety parameter values (errors parameters of channel 1; internal values are
caused by accidental overwriting are detected). recalculated and loaded).
Values are required for all safety monitoring Start command S-0-0099, C0500 Reset class 1
functions and are of fundamental importance for diagnostics in order to clear error and then set drive
functioning of safety technology enable again
F7040 - Attributes
Display: F7040
Mess. no.: F7040 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-38 Error Messages Rexroth IndraDrive
Cause Remedy
Actual position values determined on channel 1 and Start command S-0-0099, C0500 Reset class 1
channel 2 are differing diagnostics in order to clear error and then set drive
enable again.
If error occurs repeatedly, replace control section or
entire drive controller
F7041 - Attributes
Display: F7041
Mess. no.: F7041 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-39
Cause Remedy
Plausibility comparison of active safety function of Start command S-0-0099, C0500 Reset class 1
channel 1 and channel 2 shows difference for more diagnostics in order to clear error and then set drive
than 5 seconds enable again
F7042 - Attributes
Display: F7042
Mess. no.: F7042 (hex)
The axis was already shut down before in order to then lock the output
stage or has been shut down in order to then activate the output stage.
After selecting "safety related drive interlock" or "safety related standstill"
the output stage cannot be switched off. The output stage is only switched
off via one channel.
If the drive already is in "safety related drive interlock" or "safety related
standstill", the output stage cannot be switched on via channel 2.
Cause Remedy
Error occurred when activating or deactivating output Replace control section or entire drive controller
stage interlock; e.g. error in output stage or feedback
F7043 - Attributes
Display: F7043
Mess. no.: F7043 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-40 Error Messages Rexroth IndraDrive
Cause Remedy
During transition to safety function "special mode Change parameterization of P-0-3233, Velocity
standstill", transition time is monitored. If transition threshold for safety related stopping process in
takes place from normal operation, time P-0-3220, useful way.
Tolerance time transition from normal operation Start command S-0-0099, C0500 Reset class 1
is used. If transition takes place from safety related diagnostics in order to clear error and then set drive
operation, time P-0-3225, Tolerance time transition enable again
from safety rel. oper. is used. If actual velocity
greater than value parameterized in P-0-3233,
Velocity threshold for safety related stopping
process is detected after tolerance time is over,
error F7050 is generated.
Parameterization of P-0-3233, Velocity threshold
for safety related stopping process does not make
sense
F7050 - Attributes
Display: F7050
Mess. no.: F7050 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-41
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-42 Error Messages Rexroth IndraDrive
The drive checks automatically whether the motor, after drive enable has
been switched off or when an error occurs, was shut down within the
delay time parameterized in S-0-0273, Maximum drive off delay time. If
not, the error F6024 is generated.
Cause Remedy
S-0-0273, Maximum drive off delay time incorrectly Check parameterization of S-0-0273, Maximum drive
parameterized off delay time and, if necessary, increase parameter
content in order to extend delay time and avoid incorrect
reaction
Brake defective or brake control resp. brake cable Check brake function and brake connection (cabling)
defective
Hardware defect on power section Replace control section or entire drive controller
F6024 - Attributes
Display: F6024
Mess. no.: F6024 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-43
Cause Remedy
Command value set for drive causes axis position 1. Clear error and switch power on
outside of positive travel range/position limit value 2. Set drive enable and preset command value that
(S-0-0049, Positive position limit value) leads back to the allowed travel range
Contact machine manufacturer in order to clarify cause
of incorrect command value
S-0-0049, Positive position limit value incorrectly Check and, if necessary, correct parameterization of
parameterized S-0-0049, Positive position limit value
F6029 - Attributes
Display: F6029
Mess. no.: F6029 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-44 Error Messages Rexroth IndraDrive
Cause Remedy
Command value set for drive causes axis position 1. Clear error and switch power on
outside of positive travel range/position limit value 2. Set drive enable and preset command value that
(S-0-0050, Negative position limit value) leads back to the allowed travel range
Contact machine manufacturer in order to clarify cause
of incorrect command value
S-0-0050, Negative position limit value incorrectly Check and, if necessary, correct parameterization of
parameterized S-0-0050, Negative position limit value
F6030 - Attributes
Display: F6030
Mess. no.: F6030 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-45
Cause Remedy
E-Stop input was controlled (0 V at digital input) Remove failure that caused E-Stop to be triggered and
clarify cause of triggering
Incorrect parameterization of digital inputs and Correct configuration of digital inputs/outputs and
outputs on control section correct it, if necessary
E-Stop switch or cable connection defective or Check function and wiring of E-Stop switch
incorrectly wired
Control section or digital inputs on control section Replace control section or entire drive controller
defective
F6034 - Attributes
Display: F6034
Mess. no.: F6034 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-46 Error Messages Rexroth IndraDrive
The compliance with the allowed travel range of linear axes is monitored
on the hardware side via two travel range limit switches. When the travel
range has been exceeded, one of the two limit switches is activated, if the
limit switches were correctly mounted.
The error F6042 is generated, if
• the controller detects that both travel range limit switches have been
simultaneously activated and
• exceeding the travel range is handled as an error (setting in
P-0-0090, Travel range limit parameter).
Cause Remedy
Due to incorrect mounting, axis activates both travel Mount travel range limit switches in such a way that they
range limit switches simultaneously are activated shortly before axis end position is reached.
Make sure the braking distance is sufficient
Travel range limit switches were incorrectly Connect travel range limit switches correctly; check
connected compliance with switching logic set in P-0-0090, Travel
range limit parameter
Switching logic of travel range limit switches does Check switching logic with regard to realized wiring,
not correspond to realized wiring adjust it in P-0-0090, Travel range limit parameter, if
necessary
F6042 - Attributes
Display: F6042
Mess. no.: F6042 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-47
The drive provides a function for monitoring travel range limit switches
(external hardware limit switches).
Cause Remedy
Travel range limit switch situated in positive direction 1. Clear error (reset button or error clearing command)
(see Project Planning Manual for motor) was and switch power on
activated because axis is outside of travel range that 2. Set drive enable and preset command value that
was defined by means of travel range limit switches leads back to the allowed travel range
Incorrect parameterization of digital inputs and Correct configuration of digital inputs/outputs and
outputs on control section correct it, if necessary
Travel range limit switch or cable is defective or Check function and wiring of travel range limit switch
incorrectly wired
Control section or digital inputs on control section Replace control section or entire drive controller
defective
F6043 - Attributes
Display: F6043
Mess. no.: F6043 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-48 Error Messages Rexroth IndraDrive
The drive provides a function for monitoring travel range limit switches
(external hardware limit switches).
Cause Remedy
Travel range limit switch situated in negative 1. Clear error (reset button or error clearing command)
direction (see Project Planning Manual for motor) and switch power on
was activated because axis is outside of travel range 2. Set drive enable and preset command value that
that was defined by means of travel range limit leads back to the allowed travel range
switches
Incorrect parameterization of digital inputs and Correct configuration of digital inputs/outputs and
outputs on control section correct it, if necessary
Travel range limit switch or cable is defective or Check function and wiring of travel range limit switch
incorrectly wired
Control section or digital inputs on control section Replace control section or entire drive controller
defective
F6044 - Attributes
Display: F6044
Mess. no.: F6044 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-49
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-50 Error Messages Rexroth IndraDrive
The master synchronization telegram (MST) was not received in the drive
in two successive SERCOS cycles.
Cause Remedy
Disturbance in the optic fiber transmission line Check all optic fiber connections in the SERCOS ring
and replace them, if necessary
Attenuation of light signals too high Measure attenuation of optic fiber cables again.
Maximum attenuation between TX and RX mustn’t
exceed 12.5 dB!
Different SERCOS cycle times in master and slave Check SERCOS cycle times in master and slave and
adjust them, if necessary
Disturbance in SERCOS interface (general) Replace control section or entire drive controller
F4001 - Attributes
Display: F4001
Mess. no.: F4001 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-51
The master data telegram (MDT) was not received in the drive in two
successive SERCOS or field bus cycles. The drive goes back to
communication phase 0.
Cause Remedy
Bus master does not send any more cyclic telegrams Switch master on and start cyclic communication; see
to the drive. These, however, are expected in manual for control unit
communication phase 4
Fiber optic cable bus: disturbance in fiber optic Check all fiber optic cable connections in SERCOS ring
transmission line
Fiber optic cable bus: Input power of light signals too Adjust transmitting power or check attenuation of fiber
low optic cable.
Light power to be measured at receiver (with test Maximum attenuation between TX and RX mustn't
mode: continuous light) must be between exceed 12.5 dB
–20 dBm (10 µW) and –5 dBm (320 µW)
Disturbance in SERCOS interface (general) Replace control section or entire drive controller
Different transmission times of master data Synchronize transmission times of master data
telegrams in master and slave telegrams in master and slave
F4002 - Attributes
Display: F4002
Mess. no.: F4002 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-52 Error Messages Rexroth IndraDrive
Cause Remedy
Error in SERCOS master module of control unit Error can only be corrected after consultation with
control unit manufacturer
F4003 - Attributes
Display: F4003
Mess. no.: F4003 (hex)
The compulsory order was not followed during the phase progression.
Cause Remedy
Error in SERCOS master module of control unit Error can only be corrected after consultation with
control unit manufacturer
F4004 - Attributes
Display: F4004
Mess. no.: F4004 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-53
Cause Remedy
Error in SERCOS master module of control unit Error can only be corrected after consultation with
control unit manufacturer
F4005 - Attributes
Display: F4005
Mess. no.: F4005 (hex)
The SERCOS master tried to carry out a phase switch without waiting for
the ready signal from the drive.
Cause Remedy
Error in SERCOS master module of control unit Error can only be corrected after consultation with
control unit manufacturer
F4006 - Attributes
Display: F4006
Mess. no.: F4006 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-54 Error Messages Rexroth IndraDrive
Communication via the field bus has failed. After the field bus had been
initialized and put into operation, the field bus watchdog reacted, i.e. not
telegram was received within the monitoring time stored in P-0-4075,
Field bus: watchdog.
Cause Remedy
Master does not exchange any cyclic data Check master status
Field bus cable not correctly connected Check connection of field bus cable
Bad transmission performance Check terminating resistors
Field bus: bus connection interrupted/blocked longer Check watchdog time parameterized in P-0-4075, Field
than watchdog time bus: watchdog and field bus connector, as well as
cable connection
F4009 - Attributes
Display: F4009
Mess. no.: F4009 (hex)
The master tries to establish communication with an I/O length that does
not correspond to the I/O length parameterized in the drive.
Cause Remedy
Different length for input data or output data than - Check parameter set in drive
drive expects in P-0-4071, Field bus: length of – Adjust master configuration
cyclic command value data channel and
P-0-4082, Field bus: length of cyclic actual value
data channel was configured in master
F4012 - Attributes
Display: F4012
Mess. no.: F4012 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-55
Cause Remedy
Controller has detected that runtime of PLC program Check task settings via IndraLogic programming user
has been exceeded interface
F4014 - Attributes
Display: F4014
Mess. no.: F4014 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-56 Error Messages Rexroth IndraDrive
F4034 Emergency-Stop
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Cause Remedy
E-Stop input was controlled (0 V at digital input) Remove failure that caused E-Stop to be triggered and
clear error (reset button or error clearing command).
Then switch power on again and clarify cause of E-Stop
triggering.
Incorrect parameterization of digital inputs and Correct configuration of digital inputs/outputs on control
outputs on control section section and correct it, if necessary
E-Stop switch or cable connection defective or Check function and wiring of E-Stop switch
incorrectly wired
Control section or digital inputs on control section Replace control section or entire drive controller
defective
F4034 - Attributes
Display: F4034
Mess. no.: F4034 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-57
At the end of the error reaction the drive goes torque-free and power is
switched off depending on the setting in P-0-0118, Power supply,
configuration.
Steps of Commissioning The drive therefore can only be commissioned again when:
1. the error reaction has been completed, i.e. the drive has stopped
(v=0!).
2. the error message was cleared by the error clearing command (cf.
S-0-0099, C0500 Reset class 1 diagnostics).
3. the cause of the error was removed.
4. the drive is in the operating mode again and power was switched on
("Ab").
5. drive enable was switched on again (0-1 edge).
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-58 Error Messages Rexroth IndraDrive
Cause Remedy
Acceleration threshold parameterized in P-0-3245, Start command S-0-0099, C0500 Reset class 1
Safety related deceleration/acceleration ramp 1 diagnostics in order to clear error an then set drive
has been exceeded enable again.
If necessary, increase value for parameter P-0-3245,
Safety related deceleration/acceleration ramp 1
F3111 - Attributes
Display: F3111
Mess. no.: F3111 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-59
Cause Remedy
A "safety related motion" safety function with Undo selection of safety related position and start
configured safety related absolute position was command S-0-0099, C0500 Reset class 1 diagnostics
selected without "safety related reference" having in order to clear error.
been established on channel 2 of safety technology Set drive enable and establish "safety related reference"
on channel 2, see P-0-3228, C4000 Homing procedure
command channel 2
F3112 - Attributes
Display: F3112
Mess. no.: F3112 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-60 Error Messages Rexroth IndraDrive
Cause Remedy
Implausible values on channel 1 and 2 resulted from Check parameterization. Then execute command
cyclic comparison of actual position values P-0-3228, C4000 Homing procedure command
channel 2
F3117 - Attributes
Display: F3117
Mess. no.: F3117 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-61
Cause Remedy
When using optional module starting lockout: Remove cause of error in wiring of inputs or replace
switch.
During plausibility check of selection signals AS_A or Then start command S-0-0099, C0500 Reset class 1
AS_B and ASn, selection signal states that are not diagnostics in order to clear error an then set drive
allowed were detected (contact error or cable break) enable again
When using optional module safety technology I/O: Remove cause of error in wiring of inputs or replace
switch.
During dynamization of safety function selection not Then start command S-0-0099, C0500 Reset class 1
all input signals are zero. Cause can be error in diagnostics in order to clear error an then set drive
wiring of input signals or short circuit of switch enable again
contacts with positive supply voltage
F3130 - Attributes
Display: F3130
Mess. no.: F3130 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-62 Error Messages Rexroth IndraDrive
Cause Remedy
When using optional module starting lockout: Remove cause of error in wiring of acknowledgment
signal.
Channel 1 monitors status of acknowledgment relay. Then start command S-0-0099, C0500 Reset class 1
If normal condition of relay is detected in spite of diagnostics in order to clear error an then set drive
activated starting lockout function or if operated enable again
condition is detected with starting lockout not active,
error message F3131 is generated. Error in wiring of
acknowledgment signal (contact error or cable
break)
When using optional module safety technology I/O: Remove cause of error in wiring of acknowledgment
signal.
During acknowledgment signal check a static high Then start command S-0-0099, C0500 Reset class 1
level (short circuit with V+) or a static low level (cable diagnostics in order to clear error and then set drive
break) was detected enable again
F3131 - Attributes
Display: F3131
Mess. no.: F3131 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-63
Cause Remedy
When bit 1 and bit 2 have been set in P-0-3210,
Safety technology control word:
F3132 - Attributes
Display: F3132
Mess. no.: F3132 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-64 Error Messages Rexroth IndraDrive
In order to lock the output stage in a safety related way when the safety
technology has detected an error, the correct functioning of the
interrupting circuit is cyclically checked. This is done on the one hand
during the actions "release output stage" and "lock output stage", on the
other hand statically while the output stage is being released or locked.
The corresponding hardware realization ensures that this is possible
without repercussion on the PWM control signals.
Note: When the safety technology has been activated, the error
F3133 only occurs in normal operation. When a safety function
is selected, the cause of the error causes the error F8133
Error when checking interrupting circuit to be triggered.
Cause Remedy
An error was detected during check of interrupting Start command S-0-0099, C0500 Reset class 1
circuit diagnostics in order to clear error an then set drive
enable again.
If error occurs repeatedly, replace control section or
entire drive controller
F3133 - Attributes
Display: F3133
Mess. no.: F3133 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-65
Cause Remedy
Error in wiring of dynamization Remove error in wiring of dynamization
Error in signal shape of dynamization signal in the Use appropriate signal source in the case of external
case of external dynamization dynamization
Parameterization of P-0-3210, Safety technology In the case of internal dynamization, per safety zone
control word does not make sense configure one axis as master for dynamization (set bit 3
in P-0-3210, Safety technology control word)
After having removed the cause start command S-0-0099, C0500 Reset
class 1 diagnostics in order to clear error and then set drive enable
again.
F3134 - Attributes
Display: F3134
Mess. no.: F3134 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-66 Error Messages Rexroth IndraDrive
Cause Remedy
Error in wiring of dynamization Remove error in wiring of dynamization
Error in signal shape of dynamization signal in the Use appropriate signal source in the case of external
case of external dynamization dynamization
After having removed the cause start command S-0-0099, C0500 Reset
class 1 diagnostics in order to clear error and then set drive enable
again.
F3135 - Attributes
Display: F3135
Mess. no.: F3135 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-67
Cause Remedy
A comparison has shown that channel 1 and Execute command P-0-3204, Synchronize and store
channel 2 are not working with the same safety safety technology IDN command; channel 2 thereby
parameters accepts parameters of channel 1
F3140 - Attributes
Display: F3140
Mess. no.: F3140 (hex)
Cause Remedy
Error in wiring of input signals or switch defective Remove cause of error in wiring of input signals or
replace switch
P-0-3221, Max. tolerance time for different Change parameterization of P-0-3221, Max. tolerance
channel states incorrectly parameterized time for different channel states
After having removed the cause start command S-0-0099, C0500 Reset
class 1 diagnostics in order to clear error and then set drive enable
again.
F3141 - Attributes
Display: F3141
Mess. no.: F3141 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-68 Error Messages Rexroth IndraDrive
Cause Remedy
Parameterized activation time has been exceeded. Change parameterization of P-0-3222, Max. activation
Parameterization of P-0-3222, Max. activation time time of enabling control in useful way
of enabling control does not make sense
Enabling control is defective or incorrectly wired Check and, if necessary, replace/correct enabling
control and wiring
After having removed the cause start command S-0-0099, C0500 Reset
class 1 diagnostics in order to clear error and then set drive enable
again.
F3142 - Attributes
Display: F3142
Mess. no.: F3142 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-69
Axis is in "safety related standstill". The output stage has been switched
off via two channels.
As soon as the axis has stopped the safety door can be opened.
Cause Remedy
Execution of internal command was aborted with Reset module by switching control voltage on and off.
timeout If error occurs repeatedly, replace control section or
entire drive controller
F3143 - Attributes
Display: F3143
Mess. no.: F3143 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-70 Error Messages Rexroth IndraDrive
Cause Remedy
Error in mechanical system of safety door Check mechanical system of safety door
Error in wiring of safety door, e.g. short circuit Check wiring of safety door
between I/O10n and 24 V or O10n and 0 V; driver at
output of O10n defective
F3145 - Attributes
Display: F3145
Mess. no.: F3145 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-71
Cause Remedy
System error on channel 2 Reset module by switching control voltage on and off.
Start command S-0-0099, C0500 Reset class 1
diagnostics in order to clear error an then set drive
enable again.
If error occurs repeatedly, replace control section or
entire drive controller
F3146 - Attributes
Display: F3146
Mess. no.: F3146 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-72 Error Messages Rexroth IndraDrive
Cause Remedy
Cyclic test of monitoring functions of safety Reset module by switching control voltage on and off.
technology channel 1 is faulty If error occurs repeatedly, replace firmware and/or
hardware
F3147 - Attributes
Display: F3147
Mess. no.: F3147 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-73
Cause Remedy
When switching to operating mode – and therefore Start command S-0-0099, C0500 Reset class 1
when activating safety technology functions – error diagnostics in order to clear error an then set drive
occurred in channel 2 enable again.
If necessary, reset module by switching control voltage
on and off
F3150 - Attributes
Display: F3150
Mess. no.: F3150 (hex)
Cause Remedy
When switching to parameter mode – and therefore Start command S-0-0099, C0500 Reset class 1
when deactivating safety technology functions - error diagnostics in order to clear error an then set drive
occurred in channel 2 (e.g. output stage cannot be enable again.
switched on/off via channel 2) If necessary, reset module by switching control voltage
on and off
F3151 - Attributes
Display: F3151
Mess. no.: F3151 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-74 Error Messages Rexroth IndraDrive
Cause Remedy
When switching to parameter mode – and therefore Start command S-0-0099, C0500 Reset class 1
when deactivating safety technology functions - error diagnostics in order to clear error an then set drive
occurred in channel 2 (e.g. output stage cannot be enable again.
switched on/off via channel 2) If necessary, reset module by switching control voltage
on and off
F3152 - Attributes
Display: F3152
Mess. no.: F3152 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-75
When the cam shaft mode is active, the drive monitors whether one of the
cam shaft profiles contains invalid elements or is incomplete.
Cause Remedy
One of cam shaft profiles is invalid Check cam shaft profiles and, if necessary, reload them
(P-0-0072, Cam shaft profile1, P-0-0092, Cam shaft
profile 2, P-0-0780, Cam shaft profile3 or P-0-0781,
Cam shaft profile4).
In case of doubt contact installation programmer or
machine manufacturer
F2005 - Attributes
Display: F2005
Mess. no.: F2005 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-76 Error Messages Rexroth IndraDrive
Cause Remedy
The MMC is used as active memory and was Put MMC in its slot at the drive controller again and then
removed from the drive controller under voltage start command S-0-0099, C0500 Reset class 1
diagnostics in order to clear error
Loose contact in MMC slot or MMC incorrectly Check fixing of MMC and, if necessary, plug it in
plugged correctly
MMC defective Replace MMC
MMC slot defective Replace control section or entire drive controller
F2006 - Attributes
Display: F2006
Mess. no.: F2006 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-77
When switching the active operating mode the drive was switched to a
non-initialized operating mode.
For the operating modes that can be selected please see Parameter
Description for the operating mode parameters:
• S-0-0032, Primary mode of operation
• S-0-0033, Secondary operating mode 1
• S-0-0034, Secondary operating mode 2
• S-0-0035, Secondary operating mode 3
Cause Remedy
Via S-0-0134, Master control word (for SERCOS) Enter the desired operating mode in the selected
or P-0-4077, Field bus: control word (for field bus) operating mode parameter
an operating mode was selected that had not been
initialized (e.g. S-0-0032="0")
F2007 - Attributes
Display: F2007
Mess. no.: F2007 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-78 Error Messages Rexroth IndraDrive
In the initialization phase (after the drive has been switched on) the
controller checks whether the connected motor type corresponds to the
type designation in S-0-0141, Motor type. If this is not the case, the error
F2008 is generated and the controller demands loading the motor-specific
control loop parameter values from the encoder memory of the motor (the
display of the control panel reads "RL").
Cause Remedy
Motor was replaced by different motor type Clear error by means of
- or - - S-0-0099, C0500 Reset class 1 diagnostics
A parameter file was loaded to drive controller in - or -
which parameter S-0-0141, Motor type differs from - Press "ESC" button at control panel of controller
connected motor type
- or - Note: If the error is cleared, command S-0-0262, C07_x
Drive controller was switched on for the first time. Load defaults procedure command is then
Motor type stored in S-0-0141, Motor type differs automatically executed, unless this was deactivated in
from connected motor type. P-0-0556, Control word of axis controller.
Attention: By command execution, previous control
loop settings are overwritten with default control loop
settings from encoder memory!
F2008 - Attributes
Display: RL
Mess. no.: F2008 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-79
During the transition checks for the communication phases 3 and 4 the
operating data (parameter values) are verified; parameters with invalid
operating data (normally only all new parameters) are output in the
S-0-0021, IDN list of invalid operating data for communication
phase 2 or S-0-0022, IDN list of invalid operating data for
communication phase 3 parameters.
Cause Remedy
Drive was started with new firmware for the first time By clearing error via control panel all parameter values
or a version update was carried out due to which are cleared and set to original values (default values)
number of non-volatile parameters has changed - or -
Error is cleared by starting command S-0-0099, C0500
Reset class 1 diagnostics. Parameters that can be
read from memory remain with their last stored value, all
parameters that cannot be read from the memory (new
parameters) are set to default values and marked as
being invalid
Parameter memory (MMC or internal memory) is Check MMC and replace it, if necessary, or
defective so that error F2009 keeps reappearing replace control section or entire drive controller
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-80 Error Messages Rexroth IndraDrive
F2009 - Attributes
Display: PL
Mess. no.: F2009 (hex)
Cause Remedy
Conflict with last stored parameters of digital Check following parameter contents and correct them, if
inputs/outputs necessary:
- P-0-0300, Digital I/Os, assignment list
- P-0-0301, Digital I/Os, bit numbers
- P-0-0302, Digital I/Os, direction
F2010 - Attributes
Display: F2010
Mess. no.: F2010 (hex)
F2011 - Attributes
Display: F2011
Mess. no.: F2011 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-81
F2012 - Attributes
Display: F2012
Mess. no.: F2012 (hex)
F2013 - Attributes
Display: F2013
Mess. no.: F2013 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-82 Error Messages Rexroth IndraDrive
F2014 - Attributes
Display: F2014
Mess. no.: F2014 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-83
Note: Before the error F2018 is triggered, the warning E2050 Device
overtemp. prewarning is output for 30 s.
Cause Remedy
Overtemperature (heat sink) due to overload of Switch drive off and let it cool down. Check mechanical
device system and drive dimensioning (working power mustn’t
exceed, on average, continuous power of drive).
Ambient temperature too high. Specified Reduce ambient temperature, e.g. by cooling the control
performance data are valid up to an ambient cabinet
temperature of 40 C.
Heat sink of device is dirty Clean heat sink
Convection is prevented by other components or Mount device vertically and provide sufficient space for
mounting position of control cabinet ventilating heat sink
Failure of internal blower If blower fails, replace device or power section
Failure of air conditioning for control cabinet Check air conditioning of control cabinet
Incorrect dimensioning of control cabinet with regard Check dimensioning of control cabinet
to heat discharge
F2018 - Attributes
Display: F2018
Mess. no.: F2018 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-84 Error Messages Rexroth IndraDrive
Note: Before the error F2019 is triggered, the warning E2050 Motor
overtemp. prewarning is output for 30 s.
Note: In the case of MHD, MKD, MKE and LSF motors, the motor
overtemperature prewarning cannot be used due to the
temperature sensor characteristic.
For MSK and MLF motors the prewarning function can be
used because an appropriate temperature sensor is used for
these motors.
Cause Remedy
Motor shutdown temperature incorrectly Check and correct parameterization of S-0-0204, Motor
parameterized shutdown temperature by means of motor or
temperature sensor data sheet
The motor is overloaded. Effective torque demanded Check dimensioning of motor. In the case of
from motor was above allowed torque for a too long installations that have been operated for a long time,
time check whether drive conditions have changed (with
regard to dirt accumulation, friction, moved masses
etc.).
Line interruption, ground fault or short circuit in line Check line for motor temperature monitoring for line
for motor temperature monitoring interruption, ground fault or short circuit
Instability in speed control loop Check parameterization of speed control loop
F2019 - Attributes
Display: F2019
Mess. no.: F2019 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-85
Cause Remedy
Interruption or short circuit in line for motor Check motor connection and cable for interruption and
temperature monitoring short circuit
Sensor in motor is defective Use replacement sensor or replace motor
Drive controller defective Replace drive controller or power section
F2021 - Attributes
Display: F2021
Mess. no.: F2021 (hex)
Cause Remedy
Sensor in drive controller is defective Replace drive controller or power section
F2022 - Attributes
Display: F2022
Mess. no.: F2022 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-86 Error Messages Rexroth IndraDrive
The DC bus voltage value is monitored by the drive controller and the
supply unit.
Drive Controllers HMS, HMD, If the DC bus voltage falls below the minimum value determined for the
HCS drive (see value of P-0-0114, Undervoltage threshold) or it reacts to
"DC bus not ok" of the module bus, the device generates the error
message F2026 if "non-fatal warning" has been set with regard to the
reaction to undervoltage in P-0-0118, Power supply, configuration.
Supply Unit HMV01.1 If the DC bus voltage falls below 75% of the mains voltage crest value
that was detected when the mains contactor had been switched on, the
error F2026 is displayed at the device. Power is switched off!
Cause Remedy
Power is switched off without previous drive Check logic for activating drive in connected control unit
deactivation by means of drive enable ("AF")
Failure in power supply or overload of power supply Check power supply
Mains failure Check cause of mains failure, switch mains voltage on
again
F2026 - Attributes
Display: F2026
Mess. no.: F2026 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-87
When the position control loop is closed the drive monitors whether it can
follow the preset position command value. To do this a actual model
position value is calculated in the drive and compared with the real actual
position value. If the difference of calculated and real actual position value
exceeds the value entered in parameter S-0-0159, Monitoring window it
is obvious that the drive cannot follow the preset command value and the
error F2028 is generated.
Cause Remedy
Parameterized monitoring window too small Check and, if necessary, correct content of S-0-0159,
Monitoring window
Too high command acceleration due to incorrect Reduce acceleration value set by the control unit (see
command value set by control unit control unit manual)
Numeric value in S-0-0092, Bipolar torque/force Check content of parameter S-0-0092, Bipolar
limit value too low torque/force limit value and set it to maximum value
allowed for application
Axis is blocked or sluggish Check mechanical system and remove axis blocking
Incorrect or non-optimized control loop parameters Check control loop setting (e. g. S-0-0104, Position
loop Kv-factor, S-0-0100, Velocity loop proportional
gain, P-0-0556, Control word of axis controller)
Acceleration capacity of drive was exceeded Check drive dimensioning
F2028 - Attributes
Display: F2028
Mess. no.: F2028 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-88 Error Messages Rexroth IndraDrive
Note: If the deviation is too great, the operational safety of the motor
is no longer guaranteed because a "runaway effect" of the
motor can occur.
Cause Remedy
Initial commissioning was not or incompletely carried Carry out initial commissioning
out
Motor encoder was replaced Carry out initial commissioning
Motor connections (U, V, W) were mixed up Check and if necessary correct motor connection
Values in P-0-0508, Commutation offset and/or Check value stored in P-0-0508, Commutation offset;
P-0-3008, Commutation offset, encoder memory carry out initial commissioning again, if required
were manipulated
F2032 - Attributes
Display: F2032
Mess. no.: F2032 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-89
If the X10 interface at the IndraDrive M controller has been equipped with
a digital I/O extension, this requires an external 24 V power supply.
Cause Remedy
Voltage externally applied is outside of allowed Supply interface with controlled power supply unit
range [and temporary failures (voltage peaks) are
detected]
At least one of the inputs was connected with Check wiring
reversed polarity
At least one of the outputs has short circuit Check wiring
At least one of the outputs is overloaded Supply motor brake and interface with different power
supply units, especially in the case of long motor cables
F2033 - Attributes
Display: F2033
Mess. no.: F2033 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-90 Error Messages Rexroth IndraDrive
Note: The monitoring function is inactive if the value "0" was entered
in the S-0-0391, Monitoring window feedback 2 parameter.
Cause Remedy
Parameters for encoder 2 incorrect Check S-0-0115, Position feedback 2 type and
S-0-0117, Feedback 2 Resolution
Mechanical system between motor shaft and Check S-0-0121, Input revolutions of load gear,
encoder 2 incorrectly parameterized S-0-0122, Output revolutions of load gear, and
S-0-0123, Feed constant
Mechanical system between motor shaft and Increase S-0-0391, Monitoring window feedback 2,
encoder 2 is not rigid (e.g. gear play, slip) and switch off in the case of gear with slip
monitoring window is too small
F2036 - Attributes
Display: F2036
Mess. no.: F2036 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-91
When the drive is running in the operating mode "position control with
cyclic command value input", the incoming position command values (cf.
S-0-0047, Position command value) are monitored. If the position
difference between two successive position command values is greater
than or equal to the value in S-0-0091, Bipolar velocity limit value, the
position command value monitor is activated and the error F2037 is
generated.
The excessive position command value is stored in parameter P-0-0010,
Excessive position command value.
The last valid position command value is stored in parameter P-0-0011,
Last valid position command value.
Cause Remedy
Value in S-0-0091, Bipolar velocity limit value too Check and, if necessary, correct parameterization of
low S-0-0091, Bipolar velocity limit value
Incorrect command value set by control unit Contact control unit manufacturer or programmer
F2037 - Attributes
Display: F2037
Mess. no.: F2037 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-92 Error Messages Rexroth IndraDrive
Cause Remedy
Value in S-0-0138, Bipolar acceleration limit value Check and, if necessary, correct parameterization of
too low S-0-0138, Bipolar acceleration limit value
Incorrect command values set by control unit Contact control unit manufacturer or programmer
(position command values)
Preset acceleration value was greater than value Reduce acceleration value used
parameterized in S-0-0138, Bipolar acceleration - S-0-0042, Homing acceleration
limit value - S-0-0260, Positioning acceleration
- P-0-0057, Return acceleration
F2039 - Attributes
Display: F2039
Mess. no.: F2039 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-93
Cause Remedy
Ambient temperature too high. Specified Reduce ambient temperature, e.g. by cooling the control
performance data are valid up to an ambient cabinet
temperature of 40 C.
Heat sink of device is dirty Clean heat sink
Convection is prevented by other components or Mount device vertically and provide sufficient space for
mounting position in control cabinet ventilating heat sink
Blower of device is defective Replace device
F2040 - Attributes
Display: F2040
Mess. no.: F2040 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-94 Error Messages Rexroth IndraDrive
Cause Remedy
Defective encoder cable or cable shielding Check cable to measuring system and replace it, if
necessary
Encoder defective Check measuring system and replace it, if necessary
Faulty mounting of measuring head in the case of Check mounting of measuring head and correct it, if
linear measuring systems necessary
Measuring system dirty Replace measuring system
Hardware defect on control section of drive Replace control section or entire drive controller
F2042 - Attributes
Display: F2042
Mess. no.: F2042 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-95
Cause Remedy
Defective encoder cable or cable shielding Check cable to measuring system and replace it, if
necessary
Encoder defective Check measuring system and replace it, if necessary
Faulty mounting of measuring head in the case of Check mounting of measuring head and correct it, if
linear measuring systems necessary
Measuring system dirty Replace measuring system
Hardware defect on control section of drive Replace control section or entire drive controller
F2043 - Attributes
Display: F2043
Mess. no.: F2043 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-96 Error Messages Rexroth IndraDrive
The external 24 V power supply for the digital I/Os at the optional module
(HCC01) is monitored by the drive.
If the 24 V power supply is outside of the range of 19 V to 30 V, the error
F2044 is generated.
Cause Remedy
Temporary failures (voltage peaks) or voltage drops Use controlled power supply unit
At least one of the inputs was connected with Check wiring incl. cable and correct it, if necessary
reversed polarity
At least one of the outputs has short circuit or is Check wiring incl. cable and remove short circuit, if
overloaded necessary
Voltage drops because motor brake applied Supply motor brake and interface with different power
supply units, especially with long motor cables
F2044 - Attributes
Display: F2044
Mess. no.: F2044 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-97
Note: The battery was designed for a service life of 10 years in its
installed state.
In the case of Rexroth motors of the MKD/MKE line, the absolute position
information is maintained, by means of battery-buffered electronics in the
motor feedback, even when the drive controller has been switched off.
The battery voltage is checked in the transition command from parameter
to operating mode during the initialization of the drive.
Cause Remedy
Battery voltage has fallen below 3.1 V Clear error and immediately arrange for and prepare
replacement of battery
(see instructions in Project Planning Manual for
respective motor). For replacement of battery observe
warning notice below!
Battery voltage has fallen below 2.8 V Error cannot be cleared any longer. Battery must be
replaced immediately
(see instructions in Project Planning Manual for
respective motor). For replacement of battery observe
warning notice below!
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-98 Error Messages Rexroth IndraDrive
Note: If the control voltage is switched off after the battery was
removed, the absolute position data reference gets lost. The
position data reference then has to be reestablished.
F2048 - Attributes
Display: F2048
Mess. no.: F2048 (hex)
Cause Remedy
There was an attempt to preset a new positioning Check command value in control unit and make sure
command value x(k+2) while drive was moving to that new positioning command value x(k+2) is only
target position of positioning command value x(k) preset when positioning command value x(k+1) was
accepted and drive moves to corresponding target
position
Incorrect command value acceptance (toggling of Check control program and only toggle bit 0 of
S-0-0346, Positioning control word) in control unit S-0-0346, Positioning control word once for each new
causes positioning command value to be accepted positioning command value, because every change of
several times the bit causes current positioning command value to be
accepted
Incorrect positioning mode for "approaching target" Set positioning mode "immediately moving to new
was set in S-0-0346, Positioning control word target" for "approaching target" in S-0-0346,
Positioning control word
F2050 - Attributes
Display: F2050
Mess. no.: F2050 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-99
Cause Remedy
When target position of a sequential block has been Preset sequential block in time (before target position
reached, there is no new positioning block in target has been reached)
position preset memory
Positioning block mode by mistake set to "sequential Check positioning block mode and switch off sequential
block without intermediate stop" block processing, if necessary (S-0-0346, Positioning
control word)
F2051 - Attributes
Display: F2051
Mess. no.: F2051 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-100 Error Messages Rexroth IndraDrive
The number of increments or lines output within the position loop cycle
(basic: TA = 500 µs, advanced: TA = 250 µs) is monitored in the drive in
order to make sure that the maximum allowed frequency of the
incremental encoder signals of 1024 kHz is not exceeded; otherwise a
position offset would be produced due to "lost increments".
Cause Remedy
Resolution set in P-0-0903, Encoder emulation Reduce number of increments of incremental encoder
resolution is too high for existing travel velocity emulator in P-0-0903, Encoder emulation resolution
- or -
Reduce travel velocity
F2053 - Attributes
Display: F2053
Mess. no.: F2053 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-101
Cause Remedy
Run time internally exceeded Switch off all functions not required (e.g. analog output).
If this does not remove error, replace control section or
entire drive controller and contact our service
department
Hardware error Replace control section or entire drive controller and
contact our service department
F2054 - Attributes
Display: F2054
Mess. no.: F2054 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-102 Error Messages Rexroth IndraDrive
Cause Remedy
Interference injection due to incorrect connection of Check connection of master communication (incl. shield
master communication cause synchronization connection) and correct it, if necessary
problems
Synchronization clock of master oscillates very much Check field bus master and make sure synchronization
due to software or hardware error in master (e.g. clock is good and constant
jitter of MST with SERCOS)
Master communication hardware of drive controller is Replace control section or entire drive controller
defective (e.g. optional SERCOS card)
F2067 - Attributes
Display: F2067
Mess. no.: F2067 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-103
Cause Remedy
Motor brake (servo brake) was not or incorrectly Connect brake or correct connection
connected
Axis is mechanically blocked Check mechanical system and remove blocking
Brake is defective Check and, if necessary, replace brake
Brake supply error Check voltage
Friction torque of axis is greater than test torque of Deactivate brake check (P-0-0525, Holding brake
drive control word) because it cannot be used due to
mechanical properties
F2069 - Attributes
Display: F2069
Mess. no.: F2069 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-104 Error Messages Rexroth IndraDrive
Cause Remedy
While turned off, axis was moved further than Make sure displayed position is correct in relation to
distance contained in P-0-0095, Absolute encoder machine zero point Then clear error and, if necessary,
monitoring window for motor encoder reestablish position data reference
Value entered in P-0-0095, Absolute encoder Check parameterization of P-0-0095, Absolute encoder
monitoring window for motor encoder is too low monitoring window for motor encoder and increase
for existing encoder resolution so that normal monitoring window
encoder jitter will already cause monitor to be
triggered
Switching on without reference Clear error and establish position data reference
(in the case of initial commissioning or caused, for
example, by changing parameters that characterize
mechanical system or influence position evaluation)
Switching on without reference Clear error and establish position data reference
(after replacing motor or motor encoder)
Amplifier replaced without parameter update Clear error and establish position data reference
Parameters of mechanical system changed (gear, Clear error and establish position data reference
feed constant, ...)
Motor encoder defective Replace motor or motor encoder
F2074 - Attributes
Display: F2074
Mess. no.: F2074 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-105
When turning off a drive with an external encoder that can be evaluated in
absolute form, the current actual position will be stored in the drive. When
switching the drive on again the current position is compared with the
position stored when the drive was switched off the last time. If the
deviation is greater than the value in P-0-0096, Absolute encoder
monitoring window for opt. encoder the F2075 error message is
generated.
Cause Remedy
While turned off, axis was moved further than Make sure displayed position is correct in relation to
distance contained in P-0-0096, Absolute encoder machine zero point Then clear error and, if necessary,
monitoring window for opt. encoder reestablish position data reference
Value entered in P-0-0096, Absolute encoder Check parameterization of P-0-0096, Absolute encoder
monitoring window for opt. encoder is too low for monitoring window for opt. encoder and increase
existing encoder resolution so that normal encoder monitoring window
jitter will already cause monitor to be triggered
Switching on without reference Clear error and establish position data reference
(in the case of initial commissioning or caused, for
example, by changing parameters that characterize
mechanical system or influence position evaluation)
Encoder defective or encoder replacement Replace encoder, clear error and establish position data
reference
Amplifier replaced without parameter update Clear error and establish position data reference
Parameters of mechanical system changed (gear, Clear error and establish position data reference
feed constant, ...)
F2075 - Attributes
Display: F2075
Mess. no.: F2075 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-106 Error Messages Rexroth IndraDrive
When turning off a drive with a measuring encoder that can be evaluated
in absolute form, the current actual position will be stored in the drive.
When switching the drive on again the current position is compared with
the position stored when the drive was switched off the last time. If the
deviation is greater than the value in P-0-0097, Absolute encoder
monitoring window for measuring encoder the F2076 error message
is generated.
Cause Remedy
While turned off, axis was moved further than Make sure displayed position is correct in relation to
distance contained in P-0-0097, Absolute encoder machine zero point Then clear error and, if necessary,
monitoring window for measuring encoder reestablish position data reference
Value entered in P-0-0097, Absolute encoder Check parameterization of P-0-0097, Absolute encoder
monitoring window for measuring encoder monitoring window for measuring encoder and
is too low for existing encoder resolution so that increase monitoring window
normal encoder jitter will already cause monitor to be
triggered
Switching on without reference Clear error and establish position data reference
(in the case of initial commissioning or caused, for
example, by changing parameters that characterize
mechanical system or influence position evaluation)
Encoder defective or encoder replacement Replace encoder, clear error and establish position data
reference
Amplifier replaced without parameter update Clear error and establish position data reference
Parameters of mechanical system changed (gear, Clear error and establish position data reference
feed constant, ...)
F2076 - Attributes
Display: F2076
Mess. no.: F2076 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-107
Cause Remedy
Hardware of control section or power section Replace power section or control section resp. entire
defective drive controller
F2077 - Attributes
Display: F2077
Mess. no.: F2077 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-108 Error Messages Rexroth IndraDrive
This error is signaled by the supply to the drives via the module bus. It
has high priority and...
• causes error reaction in the drives in operation. The error message is
displayed at these drives.
• causes power of the supply unit to be switched off or the Bb contact of
converters to open (requires assignment of respective bit P-0-0861,
Status word of power section to digital output!) and possibly causes
DC bus short circuit (requires corresponding wiring!).
This error can also have been caused by a fatal drive error that was
signaled to the supply via the module bus. The respective settings must
be made in P-0-0118, Power supply, configuration.
Cause Remedy
Failure in power supply or overload of power supply Check power supply
Fatal error message of one or several drives of a Identify drive or drives signaling a fatal error. Remove
drive system and message signaled to supply cause of error at respective drive or drives
(configuration P-0-0118)
F2086 - Attributes
Display: F2086
Mess. no.: F2086 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-109
Cause Remedy
Failure of control voltage supply of a module bus Supply all devices of "drive system" with control voltage
node while the "drive system" is ready for power
output or in operation
Disturbance on module bus Identify and remove sources of disturbance
Incorrect signal timing on module bus Identify and replace faulty device
Module bus cable defective Identify and replace defective module bus cable, replace
device, if necessary
F2087 - Attributes
Display: F2087
Mess. no.: F2087 (hex)
Cause Remedy
Failure occurs sporadically (firmware error) Clear error and contact our service department for
firmware update
Should error occur repeatedly, Hardware in control Replace control section or entire drive controller
section is defective
F2100 - Attributes
Display: F2100
Mess. no.: F2100 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-110 Error Messages Rexroth IndraDrive
Cause Remedy
Failure occurs sporadically (firmware error) Clear error and contact our service department in order
to get a firmware update
MMC has not been plugged in correctly or is Clear error and check MMC or plug it in correctly. If error
defective occurs again when MMC is accessed, MMC has to be
replaced
MMC slot in control section is defective Clear error and check MMC slot. If error occurs again
when MMC is accessed, control section or entire drive
controller has to be replaced
F2101 - Attributes
Display: F2101
Mess. no.: F2101 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-111
Cause Remedy
Failure occurs sporadically (firmware error) Clear error and contact our service department in order
to get a firmware update
Encoder cable defective or bad shielding Clear error. Replace defective encoder cable or improve
shielding
Encoder memory or encoder electronics is defective Clear error. Replace encoder or motor
Hardware defect on control section Replace control section or entire drive controller
F2102 - Attributes
Display: F2102
Mess. no.: F2102 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-112 Error Messages Rexroth IndraDrive
Cause Remedy
Failure occurs sporadically (firmware error) Clear error and contact our service department in order
to get a firmware update
Encoder cable defective or bad shielding Clear error. Replace defective encoder cable or improve
shielding
Encoder memory or encoder electronics is defective Clear error. Replace encoder or motor
Hardware defect on control section Replace control section or entire drive controller
F2103 - Attributes
Display: F2103
Mess. no.: F2103 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-113
The commutation offset value stored in the motor encoder memory was
detected to be invalid.
Cause Remedy
Failure occurs sporadically (firmware error) Clear error. Then execute command P-0-0524, C1200
Commutation offset setting command; if error occurs
again contact our service department in order to get a
firmware update
Encoder memory or encoder electronics is defective Clear error. Replace encoder or motor. Then execute
command P-0-0524, C1200 Commutation offset
setting command.
F2104 - Attributes
Display: F2104
Mess. no.: F2104 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-114 Error Messages Rexroth IndraDrive
Cause Remedy
Failure occurs sporadically (firmware error) Clear error and contact our service department for
firmware update
Hardware defective Should error occur repeatedly, control section or entire
device has to be replaced
F2110 - Attributes
Display: F2110
Mess. no.: F2110 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-115
Cause Remedy
Switching on without reference Clear error and reestablish position data reference
(in the case of initial commissioning or caused, for
example, by changing parameters that characterize
mechanical system or influence position evaluation)
Switching on without reference Clear error and establish position data reference
(after replacing motor or motor encoder)
Motor encoder defective Replace motor or motor encoder, clear error and
establish position data reference
Parameters of mechanical system changed (gear, Clear error and establish position data reference
feed constant, ...)
Amplifier replaced without parameter update Clear error and establish position data reference
Switching on without reference after replacement of Clear error and establish position data reference
device with loaded axis-specific parameter values - or -
(according to list from S-0-0192, IDN-list of backup Clear error, then load parameter values of P-0-0195,
operation data) IDN list of retain data (replacement of devices), if it
was possible to save them immediately before device
was replaced. Check reestablished position data
reference for correctness
F2174 - Attributes
Display: F2174
Mess. no.: F2174 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-116 Error Messages Rexroth IndraDrive
Cause Remedy
Switching on without reference Clear error and reestablish position data reference
(in the case of initial commissioning or caused, for
example, by changing parameters that characterize
mechanical system or influence position evaluation)
Switching on without reference Clear error and establish position data reference
(after replacement of encoder)
Optional encoder defective Replace encoder, clear error and establish position data
reference
Parameters of mechanical system changed (gear, Clear error and establish position data reference
feed constant, ...)
Amplifier replaced without parameter update Clear error and establish position data reference
Switching on without reference after replacement of Clear error and establish position data reference
device with loaded axis-specific parameter values - or -
(according to list from S-0-0192, IDN-list of backup Clear error, then load parameter values of P-0-0195,
operation data) IDN list of retain data (replacement of devices), if it
was possible to save them immediately before device
was replaced. Check reestablished position data
reference for correctness
F2175 - Attributes
Display: F2175
Mess. no.: F2175 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-117
Cause Remedy
Switching on without reference Clear error and establish position data reference
(in the case of initial commissioning or caused, for
example, by changing parameters that characterize
mechanical system or influence position evaluation)
Encoder defective Replace measuring encoder, clear error and establish
position data reference
Switching on without reference Clear error and establish position data reference
(after replacement of measuring encoder)
Controller replaced without parameter update Clear error and establish position data reference
F2176 - Attributes
Display: F2176
Mess. no.: F2176 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-118 Error Messages Rexroth IndraDrive
With active modulo scaling the drive limits its actual position values to the
values parameterized in S-0-0103, Modulo value, otherwise to the value
parameterized in S-0-0278, Maximum travel range. As these values
possibly cannot be exactly displayed, the corresponding recalculation of
the systematic errors in the case of position overflow takes place in the
drive.
Cause Remedy
S-0-0103, Modulo value or S-0-0278, Maximum Check and, if necessary, correct S-0-0103, Modulo
travel range have been incorrectly parameterized value or S-0-0278, Maximum travel range
and not adjusted to the application
Drive was moved as rapidly that recalculation no Reduce drive velocity at position overflow
longer works correctly
F2177 - Attributes
Display: F2177
Mess. no.: F2177 (hex)
According to scaling, the drive limits the actual position values to the
maximum travel range or to the modulo value. As these values possibly
cannot be exactly displayed the corresponding recalculation of the errors
takes place in the drive.
Cause Remedy
Encoder speed was so high that recalculation no Reduce encoder speed
longer works correctly - or –
change S-0-0103, Modulo value
F2178 - Attributes
Display: F2178
Mess. no.: F2178 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-119
With active modulo scaling the drive limits its actual position values to the
values parameterized in S-0-0103, Modulo value, otherwise to the value
parameterized in S-0-0278, Maximum travel range. As these values
possibly cannot be exactly displayed, the corresponding recalculation of
the systematic errors in the case of position overflow takes place in the
drive.
Cause Remedy
S-0-0103, Modulo value or S-0-0278, Maximum Check and, if necessary, correct S-0-0103, Modulo
travel range have been incorrectly parameterized value or S-0-0278, Maximum travel range
and not adjusted to the application
Drive was moved as rapidly that recalculation no Reduce drive velocity at position overflow
longer works correctly
F2179 - Attributes
Display: F2179
Mess. no.: F2179 (hex)
Cause Remedy
At least one phase is missing Check and, if necessary, replace mains circuit breakers
Mains voltage is too low Measure mains voltage and compare it to allowed value
range
Mains frequency is outside of specified range Measure mains frequency and compare it to allowed
value range
F2802 - Attributes
Display: F2802
Mess. no.: F2802 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-120 Error Messages Rexroth IndraDrive
The crest value of the mains voltage has fallen below the allowed
minimum value (connection voltage range see documentation for
HMV01.1).
Cause Remedy
Mains voltage below minimum value Use matching transformer
F2814 - Attributes
Display: F2814
Mess. no.: F2814 (hex)
Cause Remedy
Mains voltage is greater than maximum specified Check mains voltage. If necessary, use matching
value (500 V+10%) transformer
F2815 - Attributes
Display: F2815
Mess. no.: F2815 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-121
During the soft start process (loading of DC bus capacitance) the DC bus
voltage curve is monitored. Great deviations suggest a defect in the
power section and are diagnosed with the error F2816.
Cause Remedy
Short circuit in DC bus Check DC bus wiring, remove if there is a short circuit
Load on DC bus Check DC bus wiring; if an external braking resistor has
been incorrectly connected, connect it correctly
Insulation error in DC bus Check DC bus wiring; if wiring is alright, there can be an
insulation error within device or other devices connected
to DC bus. To find defective device take connected
devices out of drive system step by step (remove wiring)
Final value of DC bus voltage is not reached within a Check whether there is defect at load externally
maximum time connected to DC bus
Inadmissible voltage fluctuations in supply mains. Check mains voltage
Mains voltage has inadmissibly dropped during soft
start process
Device is defective Replace device
F2816 - Attributes
Display: F2816
Mess. no.: F2816 (hex)
Cause Remedy
See E8025 Overvoltage in power section See E8025 Overvoltage in power section
F2817 - Attributes
Display: F2817
Mess. no.: F2817 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-122 Error Messages Rexroth IndraDrive
Cause Remedy
Mains circuit breaker defective Replace mains circuit breaker
Incorrect wiring Check and correct wiring
F2818 - Attributes
Display: F2818
Mess. no.: F2818 (hex)
The mains has failed. The DC bus voltage has fallen below a threshold
value so that a new soft start process is required.
Cause Remedy
Mains failure (permanent or temporary) Search and remove cause of mains failure
F2819 - Attributes
Display: F2819
Mess. no.: F2819 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-123
Note: After having eliminated the cause of the error check the
braking resistor for operatability!
Cause Remedy
Allowed deceleration of connected drives too high Reduce deceleration of connected drives
Energy absorption capacity of braking resistor is Switch power supply off with a delay in the case of drive
exhausted OFF or E-STOP (for regenerative supplies) or reduce
velocity
Regenerated energy in machining cycle is too high Increase cycle time or reduce maximum velocity
Continuous regenerative power and/or rotary drive Reduce maximum velocity or check dimensioning of
energy is too high braking resistor and, if necessary, increase
dimensioning
Device is defective Replace device
F2820 - Attributes
Display: F2820
Mess. no.: F2820 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-124 Error Messages Rexroth IndraDrive
Note: The error can occur for devices of both the HCS and the HMV
type. There are different causes and remedies for both device
types!
Cause Remedy
Control of braking resistor has detected inadmissibly Check braking resistor for correct resistance value. If
high current necessary, use braking resistor with higher resistance
value
Terminal connectors for external braking resistor Remove short circuit, connect braking resistor correctly,
have been short-circuited if necessary
Cause Remedy
Device is defective Replace device
F2821 - Attributes
Display: F2821
Mess. no.: F2821 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-125
For devices of the HCS type this error message is generated when the
parameterized braking resistor reference switch-on voltage is too low. The
braking resistor would already be active with correct DC bus voltage.
Cause Remedy
th
This error message is generated for devices of type Increase value of 4 list element in P-0-0858, Data of
HCS when the value of the braking resistor reference external braking resistor
switch-on voltage (list element 4 of P-0-0858, Data - or -
of external braking resistor) activated via Select different reference value for ON-OFF switching
P-0-0860, Control word of power section is too voltage of braking resistor in P-0-0860, Control word of
low power section
F2825 - Attributes
Display: F2825
Mess. no.: F2825 (hex)
During the loading process of the DC bus a ground fault was detected in
the motor line of one of the connected converters/inverters.
Cause Remedy
Ground fault in a motor line within drive system Take controllers of drive system successively out of
- or – device group on control voltage and power voltage side,
Ground fault in a controller of drive system until error no longer occurs. By doing this identify faulty
drive.
Check insulation of motor cable with measuring device.
If motor cable is not defective, there is a device or
connection error
F2833 - Attributes
Display: F2833
Mess. no.: F2833 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-126 Error Messages Rexroth IndraDrive
Cause Remedy
Mains contactor could not be switched Replace device
Contactor monitor has detected an error Replace device
F2834 - Attributes
Display: F2834
Mess. no.: F2834 (hex)
Cause Remedy
F2836 is signaled during loading of DC bus ("soft Replace device
start")
F2836 - Attributes
Display: F2836
Mess. no.: F2836 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-127
Cause Remedy
A second supply unit or converter connected in Remove cause of error at respective supply unit /
parallel signals a supply error converter and clear error
F2840 - Attributes
Display: F2840
Mess. no.: F2840 (hex)
For HCS, HMS, HMD The current in the power transistor bridge has exceeded the maximum
allowed device peak current. The drive is immediately de-energized, the
motor coasts to stop.
For HMV01.1R The current in the mains-side power bridge has exceeded the maximum
allowed value. The power supply is switched off.
Cause Remedy
Short circuit in motor or motor cable Check motor cable and motor for short circuit
Device defective Replace device
Current loop parameterized differently (not for Check current loop parameters to see whether they
HMV01.1R) differ from the parameters on the motor data sheet;
correct them if necessary
F2860 - Attributes
Display: F2860
Mess. no.: F2860 (hex)
Cause Remedy
Device defective Replace device
F2890 - Attributes
Display: F2890
Mess. no.: F2890 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-128 Error Messages Rexroth IndraDrive
Cause Remedy
Device defective Replace device
F2891 - Attributes
Display: F2891
Mess. no.: F2891 (hex)
Cause Remedy
Device defective Replace device
F2892 - Attributes
Display: F2892
Mess. no.: F2892 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Error Messages 7-129
-> continuation...
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
7-130 Error Messages Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-1
Note: Only for HMV: If the warning E8025 persists for more than
2 seconds, the error F2817 Overvoltage in power section is
generated.
Cause Remedy
Energy regenerated to DC bus by mechanical Reduce regenerative power by lower acceleration
machine system during braking process was so high values
that supply unit couldn’t dissipate it during – or –
regeneration time. This caused DC bus voltage to Correct drive dimensioning
rise to inadmissible value – or –
Dimension supply unit sufficiently with regard to braking
energy requirements; if dimensioning of available
braking resistor is insufficient, use additional braking
resistor, if necessary
Mains supply voltage (alternating input voltage) too Check mains supply voltage (alternating
high voltage/3-phase)
No braking resistor connected or connection or cable Connect braking resistor or check connection
defective
E8025 - Attributes
Display: E8025
Mess. no.: E8025 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-2 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Current loop incorrectly parameterized Check current loop setting (S-0-0106, Current loop
proportional gain 1, S-0-0107, Current loop integral
action time 1) and, if necessary, correct it after having
contacted our service department
In the case of Bosch Rexroth motors with encoder Check whether values in S-0-0106, Current loop
data memory (MHD, MKD, MKE), values for current proportional gain 1 and S-0-0107, Current loop
loop parameterization do not correspond to values in integral action time 1 correspond to values in encoder
encoder data memory data memory (P-0-2106, Current loop proportional
gain 1, encoder memory and P-0-2107, Current loop
integral-action time 1, encoder memory)
In the case of Rexroth motors without encoder data Check whether values in S-0-0106, Current loop
memory, values for current loop parameterization do proportional gain 1 and S-0-0107, Current loop
not correspond to manufacturer-side specifications integral action time 1 correspond to manufacturer-side
specifications (see DriveTop)
In the case of third-party motors, output data for Check whether output data for calculating parameter
calculating parameter values are not correct values are correct
E8028 - Attributes
Display: E8028
Mess. no.: E8028 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-3
Cause Remedy
A command value was set for the drive that causes Set command value that leads back to the allowed travel
an axis position outside the positive travel range.
range/position limit value Contact machine manufacturer in order to find out cause
of incorrect command value
Positive travel range/position limit value incorrectly Check and, if necessary, correct parameterization of
parameterized S-0-0049, Positive position limit value
E8029 - Attributes
Display: E8029
Mess. no.: E8029 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-4 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
A command value was set for the drive that causes Set command value that leads back to the allowed travel
an axis position outside the negative travel range.
range/position limit value Contact machine manufacturer in order to find out cause
of incorrect command value
Positive travel range/position limit value incorrectly Check and, if necessary, correct parameterization of
parameterized S-0-0050, Negative position limit value
E8030 - Attributes
Display: E8030
Mess. no.: E8030 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-5
E8034 Emergency-Stop
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Note: When the warning E8034 occurs, the axis is shut down as fast
as can with velocity command value reset.
There isn’t any message transmitted to the control unit.
Cause Remedy
E-Stop input was controlled (0 V at digital input) Remove failure that caused E-Stop to be triggered and
clarify cause of triggering
Incorrect parameterization of digital inputs and Correct configuration of digital inputs/outputs on control
outputs on control section section and correct it, if necessary
E-Stop switch or cable connection defective or Check function and wiring of E-Stop switch
incorrectly wired
Control section or digital inputs on control section Replace control section or entire drive controller
defective
E8034 - Attributes
Display: E8034
Mess. no.: E8034 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-6 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
The warning E8040 is generated when the "stall protection loop" takes
effect and changes the working point of the machine for its relief.
Note: The axis is shut down as fast as can with velocity command
value reset. There isn’t any message transmitted to the control
unit.
Cause Remedy
Load torque is too high Reduce load torque
Torque limit values incorrectly parameterized Check parameters S-0-0082, Torque/force limit value
positive; S-0-0083, Torque/force limit value negative;
S-0-0092, Bipolar torque/force limit value and
P-0-0109, Torque/force peak limit and increase limits,
if necessary
E8040 - Attributes
Display: E8040
Mess. no.: E8040 (hex)
The warning E8041 is generated when the current limitation loop takes
effect and reduces the output voltage due to overvoltage.
Note: The axis is shut down as fast as can with velocity command
value reset. There isn’t any message transmitted to the control
unit.
Cause Remedy
S-0-0109, Motor peak current incorrectly Check content of S-0-0109, Motor peak current and
parameterized increase it, if necessary
Short circuit at output of power output stage (e.g. in Check motor connection and motor for short circuit and
motor cable or in motor) replace cable or motor, if necessary
Power output stage in drive controller defective Replace drive controller
E8041 - Attributes
Display: E8041
Mess. no.: E8041 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-7
The compliance with the allowed travel range of linear axes is monitored
on the hardware side via two travel range limit switches. When the travel
range has been exceeded, one of the two limit switches is activated, if the
limit switches were correctly mounted.
The warning E8042 is generated, if
• the controller detects that both travel range limit switches have been
simultaneously activated and
• exceeding the travel range is handled as a fatal warning (setting in
P-0-0090, Travel range limit parameter).
Note: Unless the cause of E8042 has not been removed the
controller does not accept any command value!
Cause Remedy
Due to incorrect mounting, axis activates both travel Mount travel range limit switches in such a way that they
range limit switches simultaneously are activated shortly before axis end position is reached.
Make sure the braking distance is sufficient
Travel range limit switches were incorrectly Connect travel range limit switches correctly; check
connected compliance with switching logic set in P-0-0090, Travel
range limit parameter
Switching logic of travel range limit switches does Check switching logic with regard to realized wiring,
not correspond to realized wiring adjust it in P-0-0090, Travel range limit parameter, if
necessary
E8042 - Attributes
Display: E8042
Mess. no.: E8042 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-8 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
The drive provides a function for monitoring travel range limit switches
(external hardware limit switches). This monitor has to be activated and
parameterized via P-0-0090, Travel range limit parameter.
Note: When the warning E8043 occurs, the axis is shut down with
velocity command value reset.
Cause Remedy
Travel range limit switch situated in positive direction Set drive enable and input a command value leading
(see Project Planning Manual for motor) was back to allowed travel range
activated because axis is outside of travel range that
was defined by means of travel range limit switches
Incorrect parameterization of digital inputs and Correct configuration of digital inputs/outputs on control
outputs on control section section and correct it, if necessary
Travel range limit switch or cable is defective or Check function and wiring of travel range limit switch
incorrectly wired
Control section or digital inputs on control section Replace control section or entire drive controller
defective
E8043 - Attributes
Display: E8043
Mess. no.: E8043 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-9
The drive provides a function for monitoring travel range limit switches
(external hardware limit switches). This monitor has to be activated and
parameterized via P-0-0090, Travel range limit parameter.
Note: When the warning E8044 occurs, the axis is shut down with
velocity command value reset.
Cause Remedy
Travel range limit switch situated in negative Set drive enable and input a command value leading
direction (see Project Planning Manual for motor) back to allowed travel range
was activated because axis is outside of travel range
that was defined by means of travel range limit
switches
Incorrect parameterization of digital inputs and Correct configuration of digital inputs/outputs on control
outputs on control section section and correct it, if necessary
Travel range limit switch or cable is defective or Check function and wiring of travel range limit switch
incorrectly wired
Control section or digital inputs on control section Replace control section or entire drive controller
defective
E8044 - Attributes
Display: E8044
Mess. no.: E8044 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-10 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Too high acceleration torque/too high acceleration Reduce acceleration by adjusted command value profile
force demanded
Overload of drive by too high continuous load Reduce overload in the case of long machining phases
Too high process or machining force (e.g. infeed) Reduce process or machining force
Mechanical changes in axis (e.g. friction, load Check mechanical system and, if necessary, optimize
conditions,...) load conditions and/or friction conditions
E8055 - Attributes
Display: E8055
Mess. no.: E8055 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-11
For HMV01.1R When the thermal load has reached 100%, the continuous current
limitation is activated and the warning E8057 is generated. As a
consequence thereof the available DC bus power is reduced and
especially drives that require high power can no longer follow the preset
command values.
Cause Remedy
Device is not adjusted to requirements of application Check dimensioning of drive and, if necessary, use
or motor more powerful device
Too high acceleration torque/too high acceleration Reduce acceleration by adjusted command value profile
force demanded
Overload of drive by too high continuous load Reduce overload in the case of long machining phases
Too high process or machining force (e.g. infeed) Reduce process or machining force
Mechanical changes in axis (e.g. friction, load Check mechanical system and, if necessary, optimize
conditions,...) load conditions and/or friction conditions
E8057 - Attributes
Display: E8057
Mess. no.: E8057 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-12 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
This fatal warning can occur for drive controllers in operation that are
interconnected via the module bus. If one of these drive controllers in
operation signals an error via the module bus, the drives that are to react
to signaled errors ("package reaction") react with shutdown. The reacting
drives display the warning E8058, the supply unit displays E2810 Drive
system not ready for operation.
The settings for error messages and error reactions for devices that are
interconnected via the DC bus and module bus are made in P-0-0118,
Power supply, configuration.
Cause Remedy
Error message of one or several drives of a drive Identify drive or drives signaling an error. Remove cause
system of error at respective drive or drives
E8058 - Attributes
Display: E8058
Mess. no.: E8058 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-13
Cause Remedy
"Closed-loop operation" In position control, reduce the preset acceleration value
Acceleration capability of drive has been exceeded. or velocity value so that the drive can follow the position
In "position control" mode this means that there is an command value characteristic
ever-increasing position deviation between
command and actual value (lag error)
"Closed-loop operation" Increase values of S-0-0082, Torque/force limit value
Torque/force limit values incorrectly parameterized positive; S-0-0083, Torque/force limit value negative;
S-0-0092, Bipolar torque/force limit value and
P-0-0109, Torque/force peak limit, if necessary
"Open-loop operation" Maximum change of velocity with which drive can follow
Acceleration capability of controlled drive has been command values is determined by the motor. This
exceeded (velocity command value ramp too steep) possibly requires adjustment of P-0-0569, Maximum
stator frequency change
E8260 - Attributes
Display: E8260
Mess. no.: E8260 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-14 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety related operation is selected, the
cause of the error causes the error F3130 Error when checking input
signals or F3141 Plausibility error of selection to be triggered.
Cause Remedy
During dynamization of safety function selection not Remove cause of error in wiring of input signals or
all input signals are zero. Cause can be error in replace switch
wiring of input signals or short circuit of switch
contacts with positive supply voltage
There are unequal channel states between Remove cause of error in wiring of input signals or
channel 1 and 2. Cause can be error in wiring of replace switch
input signals or defective switch
P-0-3221, Max. tolerance time for different Change parameterization of P-0-3221, Max. tolerance
channel states incorrectly parameterized time for different channel states
E3100 - Attributes
Display: E3100
Mess. no.: E3100 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-15
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety related operation is selected, the
cause of the error causes the error F3131 Error when checking
acknowledgment signal to be triggered.
Cause Remedy
Error in wiring of acknowledgment signals (contact Remove error in wiring of acknowledgment signals
error or cable break)
E3101 - Attributes
Display: E3101
Mess. no.: E3101 (hex)
When both safety technology channels have been homed, their actual
position values are cyclically checked for plausibility.
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3117 Plausibility error of actual position
values to be triggered.
Cause Remedy
Implausible values on channel 1 and 2 resulted from Establish safety related reference again (directly via
cyclic comparison of actual position values P-0-3228, C4000 Homing procedure command
channel 2 or indirectly via S-0-0148, C0600 Drive-
controlled homing procedure command).
E3102 - Attributes
Display: E3102
Mess. no.: E3102 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-16 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3134 Dynamization time interval incorrect or
F3135 Dynamization pulse width incorrect to be triggered.
Cause Remedy
There doesn’t occur any dynamization pulse at the Remove cause of error in wiring of dynamization input
dynamization input within the time P-0-3223, Time
interval for dynamization of safety function
selection or the pulse width differs from the
parameterized time P-0-3224, Duration of
dynamization pulse of safety function selection
E3103 - Attributes
Display: E3103
Mess. no.: E3103 (hex)
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3140 Plausibility error of safety parameters to
be triggered.
Cause Remedy
A comparison has shown that channel 1 and Execute command P-0-3204, Synchronize and store
channel 2 are not working with the same safety safety technology IDN command; channel 2 thereby
parameters accepts parameters of channel 1
E3104 - Attributes
Display: E3104
Mess. no.: E3104 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-17
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F7042 Plausibility error safety related operating
mode to be triggered.
Cause Remedy
During comparison of active safety function of Reboot drive. If drive generates warning again,
channel 1 and channel 2 a difference was detected hardware has to be replaced
for more than 5 seconds
E3105 - Attributes
Display: E3105
Mess. no.: E3105 (hex)
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3146 System error channel 2 to be triggered.
Cause Remedy
System error on channel 2 Reset module, replace hardware if error occurs
repeatedly
E3106 - Attributes
Display: E3106
Mess. no.: E3106 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-18 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3145 Error when unlocking the safety door to
be triggered.
Cause Remedy
In normal operation drive detected that safety door Close safety door or check wiring of safety door
has been unlocked
E3107 - Attributes
Display: E3107
Mess. no.: E3107 (hex)
Cause Remedy
Setting of time interval in parameter P-0-0103, Time Set time interval in parameter P-0-0103, Time interval
interval of forced dynamization does not comply of forced dynamization according to requirements
with requirements
Starting lockout has not been activated within time Activate starting lockout with drive controller being
interval that was set active
E3110 - Attributes
Display: E3110
Mess. no.: E3110 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-19
E2011 - Attributes
Display: E2011
Mess. no.: E2011 (hex)
E2012 - Attributes
Display: E2012
Mess. no.: E2012 (hex)
E2013 - Attributes
Display: E2013
Mess. no.: E2013 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-20 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
E2014 - Attributes
Display: E2014
Mess. no.: E2014 (hex)
The DC bus voltage value is monitored by the drive controller and the
supply unit.
Drive Controllers HMS, HMD, If the DC bus voltage falls below the minimum value determined for the
HCS drive or it reacts to "DC bus not ok" of the module bus (see value of
P-0-0114, Undervoltage threshold), the device generates the warning
E2026 if "non-fatal warning" has been set with regard to the reaction to
undervoltage in P-0-0118, Power supply, configuration.
Supply Unit HMV01.1 If the DC bus voltage falls by 80 V below the command value of 750 V
direct voltage, the warning E2026 is displayed at the device. The circuit is
not interrupted yet!
Cause Remedy
Power is switched off without previous drive Check logic for activating drive in connected control unit
deactivation by means of drive enable ("AF")
Malfunction or overload of power supply Check power supply
Mains failure Check cause of mains failure, switch mains voltage on
again
E2026 - Attributes
Display: E2026
Mess. no.: E2026 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-21
Cause Remedy
Ambient temperature too high. Specified Reduce ambient temperature, e.g. by cooling the control
performance data are valid up to an ambient cabinet
temperature of 40 C
Heat sink of device is dirty Clean heat sink
Convection is prevented by other components or Mount device vertically and provide sufficient space for
mounting position of control cabinet ventilating heat sink
Blower of device is defective Replace device
E2040 - Attributes
Display: E2040
Mess. no.: E2040 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-22 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Incorrect velocity is preset (value = "0") Check parameterization or cyclic command value of
(cf. S-0-0259, Positioning velocity, S-0-0041, control unit and set value for preset velocity unequal
Homing velocity, P-0-4007, Positioning block zero
velocity[i], S-0-0222, Spindle positioning speed,
S-0-0091, Bipolar velocity limit value)
Analog input to which preset velocity was assigned Check wiring and function of analog input and, if
is defective or not connected necessary, replace cable or control section, or the entire
drive controller
E2047 - Attributes
Display: E2047
Mess. no.: E2047 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-23
Cause Remedy
Incorrect acceleration is preset (value = "0") Check parameterization or cyclic command value of
(vgl. S-0-0260, Positioning acceleration, S-0-0042, control unit and set value for preset acceleration > "0"
Homing acceleration, S-0-0138, Bipolar
acceleration limit value, S-0-0359, Positioning
deceleration)
E2048 - Attributes
Display: E2048
Mess. no.: E2048 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-24 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Incorrect velocity is preset (parameterized or Check parameterization or cyclic command value of
cyclically preset value is too high) control unit and set value for preset velocity higher than
(cf. S-0-0259, Positioning velocity, S-0-0041, value for S-0-0091, Bipolar velocity limit value
Homing velocity, P-0-4007, Positioning block
velocity[i], S-0-0222, Spindle positioning speed,
S-0-0091, Bipolar velocity limit value)
S-0-0091, Bipolar velocity limit value incorrectly Control parameter content of S-0-0091, Bipolar velocity
parameterized limit value and check whether parameter has been
assigned to an analog input or is contained in cyclic
data
Analog input to which S-0-0091, Bipolar velocity Check wiring and function of analog input and, if
limit value was assigned is defective or not necessary, replace cable or control section, or the entire
connected drive controller
E2049 - Attributes
Display: E2049
Mess. no.: E2049 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-25
Cause Remedy
Amplifier overtemperature (heat sink) due to Switch drive off and let it cool down, check mechanical
overload of drive (overcurrent) system as well as drive dimensioning (working power
mustn’t exceed, on average, continuous power of drive)
Ambient temperature too high. Specified Reduce ambient temperature, e. g. by cooling the
performance data are valid up to an ambient control cabinet
temperature of 40 C
Heat sink of device is dirty Clean heat sink
Convection is prevented by other components or Mount device vertically and provide sufficient space for
mounting position of control cabinet ventilating heat sink
Failure of internal blower If blower fails, replace device or power section
Failure of air conditioning for control cabinet Check air conditioning of control cabinet
Incorrect dimensioning of control cabinet with regard Check dimensioning of control cabinet
to heat discharge
E2050 - Attributes
Display: E2050
Mess. no.: E2050 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-26 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Note: In the case of MHD, MKD, MKE and LSF motors, the motor
overtemperature prewarning cannot be used due to the
temperature sensor characteristic!
For MSK and MLF motors the prewarning function can be
used because an appropriate temperature sensor is used for
these motors.
Cause Remedy
S-0-0201, Motor warning temperature incorrectly Check and correct parameterization of S-0-0201, Motor
parameterized warning temperature by means of motor or
temperature sensor data sheet
The motor is overloaded. Effective torque demanded Check motor dimensioning and reduce motor load, e.g.
by the motor was above allowed torque for a too long by reduced infeed velocity in the case of metal-cutting
time machining. In the case of installations that have been
operated for a long time, check whether drive conditions
have changed (with regard to dirt accumulation, friction,
moved masses etc.).
Line interruption, ground fault or short circuit in line Check line for motor temperature monitoring for line
for motor temperature monitoring interruption, ground fault or short circuit
Instability in speed control loop Check parameterization of speed control loop
E2051 - Attributes
Display: E2051
Mess. no.: E2051 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-27
Note: When the position limit value monitor has been activated and
the target position is outside the allowed travel range, the drive
stops or it does not accept the target position or positioning
block. In parameter S-0-0012, Class 2 diagnostics a warning
bit is set.
Cause Remedy
Position limit values (S-0-0049, Positive position Check parameterization of position limit values and
limit value, S-0-0050, Negative position limit adjust it according to desired travel range (S-0-0049,
value) incorrectly parameterized Positive position limit value must be higher than
S-0-0050, Negative position limit value)
Position limit value monitor has been activated Deactivate position limit value monitor if it is not needed
although it is not needed (e. g. in modulo operation)
In the case of relative interpolation, value for travel Check travel range (cf. S-0-0258, Target position) and,
range was set too high or several travel ranges that if necessary, adjust it in control unit program
are added cause effective target position (cf.
P-0-0050, Effective target position) to be outside
of position limits
In the case of absolute interpolation, preset target Check preset target position (cf. S-0-0258, Target
position is incorrect position or S-0-0282, Positioning command value)
and, if necessary, adjust it in control unit program (only
enter S-0-0258, Target position within position limit
values)
In "positioning block mode" one or more target Check parameterized target positions in P-0-4006,
positions have been incorrectly parameterized or Positioning block target position and block selection
incorrect positioning block is selected (P-0-4026, Positioning block selection). In addition,
check block selection via respective master
communication (e. g. field bus or digital I/Os)
E2053 - Attributes
Display: E2053
Mess. no.: E2053 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-28 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Note: When the warning E2054 appears, the drive stops or does not
accept the target position or the positioning block. In
parameter S-0-0012, Class 2 diagnostics a warning bit is set.
Cause Remedy
Absolute positioning was started although position Establish absolute position data reference by starting
data reference of drive had not yet been established command S-0-0148, C0600 Drive-controlled homing
[drive has not been homed (cf. S-0-0403, Position procedure command or P-0-0012, C0300 Command
feedback value status)] Set absolute measuring
E2054 - Attributes
Display: E2054
Mess. no.: E2054 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-29
Cause Remedy
Parameter S-0-0108, Feedrate override was set to Set feedrate override > "0" so that drive moves. Full
"0" velocity is reached with 100%.
For devices with analog inputs: feedrate override via Apply voltage > "0" proportionally to desired velocity
analog input has been activated and voltage at (+10 V corresponds to 100% of velocity)
analog input is "0" alternative: deactivate feedrate override
Infeed potentiometer of connected control unit was Carefully actuate infeed potentiometer, check analog
set to "0" or is incorrectly evaluated signal and evaluation
Analog input used for feedrate override or Check and if necessary replace cable and control
connecting cable is defective section
E2055 - Attributes
Display: E2055
Mess. no.: E2055 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-30 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
One of the torque-/force-limiting parameters has the Check parameters S-0-0082, Torque/force limit value
value "0" positive; S-0-0083, Torque/force limit value negative;
S-0-0092, Bipolar torque/force limit value and
P-0-0109, Torque/force peak limit and enter "correct"
limit value (unequal "0")
One of the torque-/force-limiting parameters has Apply voltage > 0 proportionally to desired torque/force
been assigned to analog input and voltage at analog limit value
input is "0" Note: Scaling of analog input defines scaling of analog
input voltage (see also Functional Description "Analog
Inputs")
Potentiometer of connected control unit was set to Carefully actuate potentiometer, check analog signal
"0" or is incorrectly evaluated and evaluation
Cable connected at analog input for torque/force Check and, if necessary, replace cable
limitation is defective
Analog input used for torque/force limitation is Replace control section or entire drive controller
defective
E2056 - Attributes
Display: E2056
Mess. no.: E2056 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-31
Note: When the warning E2058 appears, the drive stops or does not
accept the selected positioning block. In parameter S-0-0012,
Class 2 diagnostics a warning bit is set.
Cause Remedy
Positioning block data of currently selected block are Check positioning block data (P-0-4006, Positioning
not available block target position, P-0-4007, Positioning block
velocity, P-0-4008, Positioning block acceleration,
P-0-4009, Positioning block jerk, and P-0-4019,
Positioning block mode) and correct respective
parameters
Incorrect positioning block selection via field bus or Check P-0-4026, Positioning block selection and
digital inputs control. If necessary, also check wiring and connection
of digital I/Os
Incorrect configuration of digital inputs causes Check configuration of digital inputs and correct it
unwanted positioning block selection accordingly
E2058 - Attributes
Display: E2058
Mess. no.: E2058 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-32 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Cyclic command value preset by control unit is Control cyclic command value and, if necessary, adjust
incorrect or too high control program
Velocity limit value parameterized too low Check and correct parameterization of S-0-0091,
Bipolar velocity limit value
E2059 - Attributes
Display: E2059
Mess. no.: E2059 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-33
The work load of the device has exceeded a threshold and a message is
generated that warns against overload which will occur if the load is not
reduced.
Devices with digital control are monitored by means of a permanently
processed temperature model. If the thermal work load approaches
100 % the continuous current limit is activated shortly after and the
warning E8057 Device overload, current limit active appears.
When the current is limited the torque/force is reduced which is not
wanted for machines and installations and can cause problems. A
warning is therefore output before this situation occurs.
For HCS, HMS, HMD The threshold value for the overload prewarning can be set in P-0-0441,
Overload warning. If the thermal work load exceeds this value the
E2061 warning is output. Useful values for P-0-0441, Overload warning
are at 80-90% so that there still is a little reserve capacity until the actual
thermal work load is reached (100%).
For HMV01.1R The threshold value for the overload prewarning is fixed to 90%. If the
thermal work load exceeds this value the E2061 warning is output. This
threshold cannot be set and therefore the warning cannot be deactivated!
Cause Remedy
Incorrect value of P-0-0441, Overload warning Increase value of P-0-0441, Overload warning, if
necessary
Overload of drive (e.g. due to too high infeed during Switch drive off and let it cool down. Check drive
machining or too high acceleration to high speed) dimensioning and command value profile
Changes in mechanical system with regard to friction In the case of installations that have been run for a long
and moved masses time, check drive conditions for changes in mechanical
system
E2061 - Attributes
Display: E2061
Mess. no.: E2061 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-34 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Cyclic command value preset by control unit is Control cyclic command value and, if necessary, adjust
incorrect or too high control program
Velocity limit value parameterized too low Check and correct parameterization of S-0-0091,
Bipolar velocity limit value
E2063 - Attributes
Display: E2063
Mess. no.: E2063 (hex)
Cause Remedy
Incorrect target position or positioning command Check target position (S-0-0258, Target position) or
value was preset positioning command value (S-0-0282, Positioning
command value) preset by control unit (master) and, if
necessary, correct control unit program
An "infinitely turning axis" is not operated in modulo Check content of S-0-0076, Position data scaling type
format and change to "modulo format"
Selected S-0-0278, Maximum travel range too Increase value of S-0-0278, Maximum travel range in
small order to increase position that can be displayed
internally in absolute form
E2064 - Attributes
Display: E2064
Mess. no.: E2064 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-35
When the drive enable was switched off the motor moved during the
automatic brake torque check (can be activated via P-0-0525, Holding
brake control word). The motor holding brake therefore no longer
provides the required holding torque (see also P-0-0547, Test torque
with holding brake applied).
Cause Remedy
Due to storage, brake is covered with oxide layer If warning occurs when drive enable is switched off, start
- or - "brake check" command in order to abrade brake, if this
Brake is wetted with oil or grease setting was made in P-0-0525, Holding brake control
word. Afterwards brake should be able to provide full
torque again
Brake is worn (see service life of brake in Project If holding torque still isn’t reached after repeated start of
Planning Manual for motor) "brake check" command (abrasion cleaning processes
of brake), motor holding brake or entire motor needs to
be replaced
Wiring or control error of brake Check wiring and connection of brake (incl. brake relay).
(hardware defect on control section) If brake control in controller (e.g. relay) is defective,
entire drive controller or control section has to be
replaced
E2069 - Attributes
Display: E2069
Mess. no.: E2069 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-36 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
The hardware checks the signals of the measuring system (encoder 1) for
inadmissible signal dips. If a signal (e.g. sin or cos) leaves the thresholds
monitored by the hardware, the warning E2074 is generated.
In the case of major failures or several signal dips in series, the error
F8022 Enc. 1: enc. signals incorr. is generated and the drive is shut
down. The warning E2074 therefore points at disturbed encoder signals
before a breakdown occurs.
Cause Remedy
Defective encoder cable or cable shielding Check cable to measuring system and replace it, if
necessary
Measuring system defective Check measuring system and replace it, if necessary
Faulty mounting of measuring head in the case of Check mounting of measuring head and correct it, if
linear measuring systems necessary
Measuring system dirty Clean or replace measuring system
Hardware defect on control section of drive Replace control section or entire drive controller
E2074 - Attributes
Display: E2074
Mess. no.: E2074 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-37
The hardware checks the signals of the measuring system (encoder 2) for
inadmissible signal dips. If a signal (e.g. sin or cos) leaves the thresholds
monitored by the hardware, the warning E2075 is generated.
In the case of major failures or several signal dips in series, the error
F2042 Encoder 2: encoder signals incorrect is generated and the drive
is shut down. The warning E2075 therefore points at disturbed encoder
signals before a breakdown occurs.
Cause Remedy
Defective encoder cable or cable shielding Check cable to measuring system and replace it, if
necessary
Measuring system defective Check measuring system and replace it, if necessary
Faulty mounting of measuring head in the case of Check mounting of measuring head and correct it, if
linear measuring systems necessary
Measuring system dirty Clean or replace measuring system
Hardware defect on control section of drive Replace control section or entire drive controller
E2075 - Attributes
Display: E2075
Mess. no.: E2075 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-38 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Defective encoder cable or cable shielding Check cable to measuring system and replace it, if
necessary
Measuring system defective Check measuring system and replace it, if necessary
Faulty mounting of measuring head in the case of Check mounting of measuring head and correct it, if
linear measuring systems necessary
Measuring system dirty Clean or replace measuring system
Hardware defect on control section of drive Replace control section or entire drive controller
E2076 - Attributes
Display: E2076
Mess. no.: E2076 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-39
The supply signals a warning regarding imminent overload via the module
bus. The warning is displayed at the drive controllers and can be
evaluated by the control master via the master communication. If there is
no relief, the module bus message "error supply module" and power off
(F2086) can occur.
Cause Remedy
Imminent overload of power supply Reduce required power by lower infeed velocity of tools.
Check dimensioning of supply
Max. energy absorption capacity of braking resistor Check dimensioning of braking resistor and, if
almost reached necessary, increase dimensioning
E2086 - Attributes
Display: E2086
Mess. no.: E2086 (hex)
After a DC bus short circuit was triggered the DC bus voltage has not
fallen below 25 Volt within 10 seconds.
Cause Remedy
Braking energy of connected drives is too high Check application
Braking resistor defective Replace device
E2800 - Attributes
Display: E2800
Mess. no.: E2800 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-40 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
DC bus voltage >900 V due to increased Check drive dimensioning and, if necessary, use
regenerated braking energy additional capacitance
Braking resistor defective or not correctly connected Check function of braking resistor (incl. cabling and
connection)
Hardware defect in brake control Replace power section or entire drive controller
E2802 - Attributes
Display: E2802
Mess. no.: E2802 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-41
Cause Remedy
Error message of one or several drives of a drive Identify drive or drives signaling an error. Remove cause
system of error at respective drive or drives
One or several drives still are in communication Switch drives to communication phase 4 ["ready for
phase 2 operation" (bb) or "drive ready" (Ab)]
E2810 - Attributes
Display: E2810
Mess. no.: E2810 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-42 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Note: This warning only occurs for drive controllers of the HCS03
type!
The crest value of the mains voltage during operation has fallen below the
parameterized threshold value. The threshold value can be individually set
by the user via P-0-0810, Minimum mains crest value.
Cause Remedy
Mains voltage falls under load Check dimensioning of mains connection, increase feed
wire cross section or use matching transformer, if
necessary
Mains voltage too low at power on Use matching transformer
E2814 - Attributes
Display: E2814
Mess. no.: E2814 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-43
Cause Remedy
Due to mains failure, mains voltage is above allowed Check mains voltage conditions
value
E2815 - Attributes
Display: E2815
Mess. no.: E2815 (hex)
Cause Remedy
DC bus voltage drops due to temporary overload Check drive dimensioning incl. devices connected at DC
bus
Required acceleration currents are too high Reduce command acceleration by adjusting travel
profile
Faulty mains connection (e.g. loose contact) Check mains connection
P-0-0114, Undervoltage threshold has not been Check and, if necessary, correct content of P-0-0114,
adjusted to conditions in mains Undervoltage threshold
E2816 - Attributes
Display: E2816
Mess. no.: E2816 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-44 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
Cause Remedy
Mains circuit breaker defective Replace mains circuit breaker
Incorrect wiring Check and correct wiring
E2818 - Attributes
Display: E2818
Mess. no.: E2818 (hex)
Cause Remedy
Mains circuit breaker defective Replace mains circuit breaker
Incorrect wiring Check and correct wiring
E2819 - Attributes
Display: E2819
Mess. no.: E2819 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Warning Diagnostic Messages (Exxxx) 8-45
90% of the energy absorption capacity of the braking resistor have been
reached.
Cause Remedy
Allowed deceleration of connected drives too high Reduce deceleration of connected drives
Energy absorption capacity of braking resistor is Switch power off with a delay in the case of OFF or
almost exhausted E-STOP (for regenerative supplies)
Regenerated energy in machining cycle is too high Increase cycle time or reduce maximum drive speed of
application
Continuous regenerative power and/or rotary drive Check dimensioning of braking resistor and, if
energy is too high necessary, increase dimensioning
E2820 - Attributes
Display: E2820
Mess. no.: E2820 (hex)
The mains voltage for power supply cannot yet be switched on for the
HCS03 converter; the device is not yet ready for loading the DC bus
capacitances.
Cause Remedy
Resistors for loading DC bus capacitances still are Wait until converter clears warning E2829
thermally loaded due to last loading process
E2829 - Attributes
Display: E2829
Mess. no.: E2829 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
8-46 Warning Diagnostic Messages (Exxxx) Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-1
9.1 Commands
Note: This status is displayed on the control panel of the drive with
"C01".
C0100 - Attributes
Display: C01
Mess. no.: C0100 (hex)
Note: This status is displayed on the control panel of the drive with
"C02".
C0200 - Attributes
Display: C02
Mess. no.: C0200 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-2 Command Diagnostic Messages Rexroth IndraDrive
C0300 - Attributes
Display: C03
Mess. no.: C0300 (hex)
The command for switching to the parameter mode was started by means
of the P-0-4023, C0400 Communication phase 2 transition parameter.
C0400 - Attributes
Display: C04
Mess. no.: C0400 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-3
Note: Only those errors can be cleared that were removed! Errors
that are still present after clearing will cause the error
message to be generated again.
C0500 - Attributes
Display: C05
Mess. no.: C0500 (hex)
C0600 - Attributes
Display: C06
Mess. no.: C0600 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-4 Command Diagnostic Messages Rexroth IndraDrive
The C07_0 message on the display of the drive controller shows that the
C07_0 Load defaults procedure command (load controller
parameters) command was activated.
The command can be started as follows:
• by means of the S-0-0262, C07_x Load defaults procedure
command parameter or
• by means of the control panel of the drive controller or
• by starting the S-0-0099, C0500 Reset class 1 diagnostics command
if the drive controller displays "RL" (occurs if the S-0-0141, Motor type
and P-0-2141, Motor type, encoder memory parameters are
different).
C0700 - Attributes
Display: C07_0
Mess. no.: C0700 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-5
C07_2 Load def. proc. com. (load def. pr. for safety techn.)
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
The C07_2 message on the display of the drive controller shows that the
C07_2 Load def. proc. com. (load def. pr. for safety techn.) command
was activated.
The command can be started as follows:
1. Enter value 165 for "load defaults procedure for safety technology" in
parameter P-0-4090, Index for C07 Load defaults procedure
2. Start S-0-0262, C07_x Load defaults procedure command
The command C07_2 Load def. proc. com. (load def. pr. for safety
techn.) deactivates the safety technology and sets all safety technology
parameters to their default value.
C0720 - Attributes
Display: C07_2
Mess. no.: C0720 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-6 Command Diagnostic Messages Rexroth IndraDrive
C0750 - Attributes
Display: C07_1
Mess. no.: C0750 (hex)
C0800 - Attributes
Display: C08
Mess. no.: C0800 (hex)
Via the control unit the S-0-0152, C0900 Position spindle command
parameter was activated.
See also Functional Description "Spindle Positioning"
C0900 - Attributes
Display: C09
Mess. no.: C0900 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-7
C1200 - Attributes
Display: C12
Mess. no.: C1200 (hex)
C1300 - Attributes
Display: C13
Mess. no.: C1300 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-8 Command Diagnostic Messages Rexroth IndraDrive
C1400 - Attributes
Display: C14
Mess. no.: C1400 (hex)
C1700 - Attributes
Display: C17
Mess. no.: C1700 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-9
C1800 - Attributes
Display: C18
Mess. no.: C1800 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-10 Command Diagnostic Messages Rexroth IndraDrive
C2000 - Attributes
Display: C20
Mess. no.: C2000 (hex)
C2100 - Attributes
Display: C21
Mess. no.: C2100 (hex)
C2200 - Attributes
Display: C22
Mess. no.: C2200 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-11
C2300 - Attributes
Display: C23
Mess. no.: C2300 (hex)
C2400 - Attributes
Display: C24
Mess. no.: C2400 (hex)
Note: The MMC can only be used as an optional memory for control
sections with MMC slot.
C2500 - Attributes
Display: C25
Mess. no.: C2500 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-12 Command Diagnostic Messages Rexroth IndraDrive
Note: The MMC can only be used as an optional memory for control
sections with MMC slot.
C2600 - Attributes
Display: C26
Mess. no.: C2600 (hex)
C2800 - Attributes
Display: C28
Mess. no.: C2800 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-13
Note: The MMC can only be used as an optional memory for control
sections with MMC slot.
C2900 - Attributes
Display: C29
Mess. no.: C2900 (hex)
C3000 - Attributes
Display: C30
Mess. no.: C3000 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-14 Command Diagnostic Messages Rexroth IndraDrive
C3100 - Attributes
Display: C31
Mess. no.: C3100 (hex)
C3200 - Attributes
Display: C32
Mess. no.: C3200 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-15
The command for setting the coordinate system (S-0-0197, C3300 Set
coordinate system procedure command) was activated.
See also Functional Description "Shifting the Position Data Reference for
Relative and Absolute Measuring Systems"
C3300 - Attributes
Display: C33
Mess. no.: C3300 (hex)
The command for shifting the coordinate system (S-0-0199, C3400 Shift
coordinate system procedure command) was activated.
See also Functional Description "Shifting the Position Data Reference for
Relative and Absolute Measuring Systems"
C3400 - Attributes
Display: C34
Mess. no.: C3400 (hex)
C3500 - Attributes
Display: C35
Mess. no.: C3500 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-16 Command Diagnostic Messages Rexroth IndraDrive
When an encoder error has occurred with the safety function active, the
drive goes to "safety related standstill" and switches the motor control off
via two channels. The unlocking of the safety door, however, in this case
is blocked. After previous visual check of the situation at the axis the
safety door can be manually unlocked by the command C3700 (P-0-3218,
Manually unlocking the safety door).
The command can be executed in the operating mode and is effective in
a selected safety function.
C3700 - Attributes
Display: C37
Mess. no.: C3700 (hex)
C3800 - Attributes
Display: C38
Mess. no.: C3800 (hex)
C3900 - Attributes
Display: C39
Mess. no.: C3900 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-17
C4000 - Attributes
Display: C40
Mess. no.: C4000 (hex)
Cause Remedy
Data block elements required in communication Write allowed operating data to the respective
phase 3 are missing or invalid parameters(these parameters can be taken from the list
S-0-0021, IDN list of invalid operating data for
communication phase 2)
A change was made in P-0-2003, Selection of Check the content of P-0-2003, Selection of functional
functional packages. Then you failed to reboot packages and reboot (i. e. switch device off and on
before trying to switch to the operating mode. again)
A change of functional packages was made in Correct respective list parameters (these parameters
P-0-2003, Selection of functional packages which can be taken from the list S-0-0021, IDN list of invalid
has an effect on customer- and application-specific operating data for communication phase 2).
parameter lists (i. e. S-0-0279) Problem can also be remedied by loading basic
parameters (S-0-0262, C07_x Load defaults
procedure command with respective setting in
P-0-4090, Index for C07 Load defaults procedure).
Internal data memory defective Contact our service department
C0101 - Attributes
Display: C0101
Mess. no.: C0101 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-18 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Parameter values required in communication Write allowed values to parameters (cf.
phase 3 are outside their allowed range of values minimum/maximum value) (these parameters can be
(minimum or maximum value) taken from list S-0-0021, IDN list of invalid operating
data for communication phase 2)
C0102 - Attributes
Display: C0102
Mess. no.: C0102 (hex)
Cause Remedy
Parameter values required in communication Write allowed values to parameters (these parameters
phase 3 cannot be processed can be taken from list S-0-0021, IDN list of invalid
operating data for communication phase 2)
C0103 - Attributes
Display: C0103
Mess. no.: C0103 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-19
Cause Remedy
in the S-0-0015, Telegram type parameter the set priority telegram (telegram type = 0..6) in S-0-0015,
telegram type 7 (configured telegram) was set Telegram type parameter
in S-0-0024, Config. list of the master data in S-0-0024, Config. list of the master data telegram
telegram there were some parameters entered that those parameters have to be entered that are contained
are not contained in S-0-0188, List of configurable in S-0-0188, List of configurable data in the MDT
data in the MDT
C0104 - Attributes
Display: C0104
Mess. no.: C0104 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-20 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
In S-0-0015, Telegram type parameter telegram Set priority telegram (telegram type = 0..6) in S-0-0015,
type 7 (configured telegram) was set Telegram type parameter
Length of configured data record in MDT that is Reduce number of configured parameters in MDT
determined by S-0-0024, Config. list of the master (S-0-0024, Config. list of the master data telegram)
data telegram exceeds the maximum allowed value
entered in S-0-0186, Length of the configurable
data record in the MDT
C0105 - Attributes
Display: C0105
Mess. no.: C0105 (hex)
Cause Remedy
in the S-0-0015, Telegram type parameter the set priority telegram (telegram type = 0..6) in S-0-0015,
telegram type 7 (configured telegram) was set Telegram type parameter
in S-0-0016, Custom amplifier telegram in S-0-0016, Custom amplifier telegram configuration
configuration list there were some parameters list those parameters have to be entered that are
entered that are not contained in S-0-0187, List of contained in S-0-0187, List of configurable data in the
configurable data in the AT AT
C0106 - Attributes
Display: C0106
Mess. no.: C0106 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-21
Cause Remedy
in the S-0-0015, Telegram type parameter the set priority telegram (telegram type = 0..6) in S-0-0015,
telegram type 7 (configured telegram) was set Telegram type parameter
the length of the configured data record in the AT reduce the number of configured parameters in the AT
that is determined by S-0-0016, Custom amplifier in S-0-0016, Custom amplifier telegram configuration
telegram configuration list, exceeds the maximum list
allowed value entered in S-0-0185, Length of the
configurable data record in the AT
C0107 - Attributes
Display: C0107
Mess. no.: C0107 (hex)
Cause Remedy
At least one of the following time slot parameters Correct respective time slot parameter(s)
exceeds the SERCOS cycle time [S-0-0002, Contact machine manufacturer or installation
SERCOS Cycle time (Tscyc)]: programmer
• S-0-0006, AT Transmission starting time (T1)
• S-0-0007, Feedb. acquisition starting time (T4)
• S-0-0008, Command value valid time (T3)
• S-0-0089, MDT Transmit starting time (T2)
Note: The definition of the times for the time slot parameters is the
responsibility of the control unit manufacturer and is specified
by SERCOS interface.
C0108 - Attributes
Display: C0108
Mess. no.: C0108 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-22 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Parameter S-0-0009, Position of data record in Parameter S-0-0009, Position of data record in MDT
MDT contains an even value. This is not allowed. must be parameterized with an odd value
C0109 - Attributes
Display: C0109
Mess. no.: C0109 (hex)
Cause Remedy
Parameter S-0-0010, Length of master data Parameter S-0-0010, Length of master data telegram
telegram contains an odd value. This is not allowed. has to be parameterized with an even value
C0110 - Attributes
Display: C0110
Mess. no.: C0110 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-23
Ursache Abhilfe
Parameterization of S-0-0009, Position of data Correct the parameterization of S-0-0009, Position of
record in MDT and S-0-0010, Length of master data record in MDT and S-0-0010, Length of master
data telegram is incorrect data telegram
C0111 - Attributes
Display: C0111
Mess. no.: C0111 (hex)
Cause Remedy
Setting of parameters S-0-0001, NC Cycle time Correct parameters S-0-0001, NC Cycle time (TNcyc)
(TNcyc) or S-0-0002, SERCOS Cycle time (TScyc) and S-0-0002, SERCOS Cycle time (TScyc).
is incorrect There are settings of 500 µs for control section
ADVANCED (or 1 ms for control section BASIC) or
integral multiples of 1 ms allowed.
C0112 - Attributes
Display: C0112
Mess. no.: C0112 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-24 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Setting of parameters S-0-0001, NC Cycle time Value of S-0-0001, NC Cycle time (TNcyc) can only be
(TNcyc) or S-0-0002, SERCOS Cycle time (TScyc) equal to or a multiple of S-0-0002, SERCOS Cycle time
is incorrect (TScyc).
Correct parameters S-0-0001, NC Cycle time (TNcyc)
and S-0-0002, SERCOS Cycle time (TScyc).
C0113 - Attributes
Display: C0113
Mess. no.: C0113 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-25
Cause Remedy
Value for S-0-0007, Feedback acquisition starting Correct S-0-0007, Feedback acquisition starting time
time (T4) is incorrect (T4).
Maximum allowed value for S-0-0007, Feedback
acquisition starting time (T4) is calculated from
S-0-0002, SERCOS cycle time (TScyc) and S-0-0005,
Minimum feedback acquisition time (T4min) as
follows:
C0114 - Attributes
Display: C0114
Mess. no.: C0114 (hex)
Cause Remedy
Value set for S-0-0089, MDT Transmit starting time Correct S-0-0089, MDT Transmit starting time (T2)
(T2) is incorrect. Drive cannot run with this value
C0115 - Attributes
Display: C0115
Mess. no.: C0115 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-26 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Value for S-0-0008, Command valid time (T3) is Check and if necessary correct setting of S-0-0089,
within value for S-0-0089, MDT Transmit starting MDT Transmit starting time (T2) and S-0-0008,
time (T2). This could cause access problems in Command valid time (T3)
SERCOS communication
C0116 - Attributes
Display: C0116
Mess. no.: C0116 (hex)
Cause Remedy
S-0-0278, Maximum travel range incorrectly Check and, if necessary, reduce parameterization of
parameterized The defined travel range is too large S-0-0278. The value of S-0-0278, Maximum travel
range is to be selected in such a way that the resulting
internal position resolution guarantees a correct
commutation of the motor.
Inappropriate measuring system (resolution) for Check resolution of measuring system and, if
maximum travel range to be displayed necessary, use a different measuring system
C0119 - Attributes
Display: C0119
Mess. no.: C0119 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-27
Note: Measuring systems with their own data memory are DSF/HSF
and resolvers, as well as measuring systems with EnDat
interface (Heidenhain company) and HIPERFACE interface
(Stegmann company).
Cause Remedy
Measuring system cable defective Check measuring system cable
Measuring system defective Replace measuring system
Encoder interface card defective Replace encoder interface card
C0120 - Attributes
Display: C0120
Mess. no.: C0120 (hex)
Cause Remedy
Parameterization P-0-0074, Encoder type 1 (motor Check whether parameterized encoder type matches
encoder) does not match interface card (e.g. EN1 interface card that has been plugged in
with EnDat encoder)
In the case of "current control with motor encoder" Enter value appropriate for motor encoder in P-0-0074,
(see P-0-0045, Control word of current Encoder type 1 (motor encoder)
controller), "operation without encoder" was
detected to have been set in P-0-0074, Encoder
type 1 (motor encoder)
Parameterization in P-0-0077, Assignment motor Correct assignment of motor encoder and optional slot
encoder->optional slot is incorrect in parameter P-0-0077, Assignment motor
encoder->optional slot
C0121 - Attributes
Display: C0121
Mess. no.: C0121 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-28 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Incorrect encoder type (S-0-0277, Position Check and, if necessary, correct S-0-0277, Position
feedback 1 type) feedback 1 type
Parameterized scaling (S-0-0076, Position data Check and, if necessary, correct S-0-0076, Position
scaling type) is incorrect data scaling type
C0122 - Attributes
Display: C0122
Mess. no.: C0122 (hex)
Cause Remedy
Parameterized value for S-0-0103, Modulo value is Correct the content of S-0-0103, Modulo value or the
greater than maximum travel range (cf. S-0-0278, value of S-0-0278, Maximum travel range
Maximum travel range)
Parameterized value for S-0-0103, Modulo value Correct content of S-0-0103, Modulo value or the gear
cannot be internally displayed with the gear ratios ratios that have been set [S-0-0121, Input revolutions
that have been set (S-0-0121/S-0-0122, of load gear/S-0-0122, Output revolutions of load
P-0-0121/P-0-0122) gear; P-0-0121, Gear 1 motor-side (motor
encoder)/P-0-0122, Gear 1 encoder-side (motor
encoder)]
C0123 - Attributes
Display: C0123
Mess. no.: C0123 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-29
Cause Remedy
Encoder memory (feedback) is defective Encoder (or motor) must be replaced
Kind of motor encoder (P-0-1000, Kind of Check content of P-0-1000, Kind of encoder 1,
encoder 1, encoder memory) is not supported by encoder memory and contact our service department
the firmware
Detected kind of encoder does not match Check control section configuration and, if necessary,
parameterized type of encoder replace control section by a correctly configured control
section or replace complete drive controller
C0124 - Attributes
Display: C0124
Mess. no.: C0124 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-30 Command Diagnostic Messages Rexroth IndraDrive
Note: Measuring systems with their own data memory are DSF/HSF
and resolvers, as well as measuring systems with EnDat
interface (Heidenhain company) and HIPERFACE interface
(Stegmann company).
Cause Remedy
Measuring system cable defective Check measuring system cable
Measuring system defective Replace measuring system
Encoder interface card defective Replace encoder interface card
C0125 - Attributes
Display: C0125
Mess. no.: C0125 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-31
Cause Remedy
The parameterization P-0-0075, Encoder type 2 Correct the parameterization of P-0-0075, Encoder
(optional encoder) does not match the interface type 2 (optional encoder)
card (e.g. EN1 with EnDat encoder)
P-0-0078, Assignment optional encoder->optional Correct the parameterization of P-0-0078, Assignment
slot incorrect optional encoder->optional slot
C0126 - Attributes
Display: C0126
Mess. no.: C0126 (hex)
Cause Remedy
Incorrect encoder type (S-0-0115, Position Check and. if necessary, correct S-0-0115, Position
feedback 2 type) feedback 2 type
Parameterized scaling (S-0-0076, Position data Check and, if necessary, correct S-0-0076, Position
scaling type) is incorrect data scaling type
C0127 - Attributes
Display: C0127
Mess. no.: C0127 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-32 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Parameterized value for S-0-0103, Modulo value is Correct content of S-0-0103, Modulo value or value of
greater than maximum travel range (cf. S-0-0278, S-0-0278, Maximum travel range
Maximum travel range)
Parameterized value for S-0-0103, Modulo value Correct content of S-0-0103, Modulo value or the gear
cannot be internally displayed with the gear ratios ratios that have been set [S-0-0121, Input revolutions
that have been set (S-0-0121/S-0-0122, of load gear/S-0-0122, Output revolutions of load
P-0-0121/P-0-0122) gear; P-0-0121, Gear 1 motor-side (motor
encoder)/P-0-0122, Gear 1 encoder-side (motor
encoder)]
Encoder resolution (S-0-0117, Feedback 2 Check and, if necessary, correct parameterization of
Resolution) incorrectly parameterized S-0-0117, Feedback 2 Resolution
Resolution of encoder does not match required Replace encoder
modulo range
C0128 - Attributes
Display: C0128
Mess. no.: C0128 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-33
Cause Remedy
Encoder memory (feedback) is defective Encoder must be replaced
Kind of motor encoder (P-0-1010, Kind of Check content of P-0-1010, Kind of encoder 2,
encoder 2, encoder memory) is not supported by encoder memory and contact our service department
the firmware
Detected kind of encoder does not match Check control section configuration and, if necessary,
parameterized type of encoder replace control section by a correctly configured control
section or replace complete drive controller
C0129 - Attributes
Display: C0129
Mess. no.: C0129 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-34 Command Diagnostic Messages Rexroth IndraDrive
In the case of absolute scaling, the maximum travel range represents the
overflow limit of the actual position values. If this travel range cannot be
displayed correctly internally so that position generation without error is
impossible, this error is generated.
Cause Remedy
S-0-0278, Maximum travel range incorrectly Check and if necessary reduce S-0-0278, Maximum
parameterized travel range
C0130 - Attributes
Display: C0130
Mess. no.: C0130 (hex)
Cause Remedy
during a firmware download there was an attempt to wait until the firmware download is completed before
switch from communication phase 2 to switching to another communication phase
communication phase 3
after a boot error (F81xx error) there was an attempt clear the error, remove its cause and then boot up the
to switch from communication phase 2 to drive again
communication phase 3
C0131 - Attributes
Display: C0131
Mess. no.: C0131 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-35
Cause Remedy
Parameterization of P-0-0556, Control word of axis Select setting "Basic performance" (cf. bit 2) in
controller does not comply with switching frequency P-0-0556, Control word of axis controller
of 12 kHz set in P-0-0001, Switching frequency of
the power output stage
Incorrect parameterization of selected switching In P-0-0001, Switching frequency of the power
frequency in P-0-0001, Switching frequency of the output stage select allowed switching frequency (see
power output stage with given controller table)
performance (= sampling rate/time)
C0132 - Attributes
Display: C0132
Mess. no.: C0132 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-36 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Measuring system cable defective Check measuring system cable
Measuring system defective Replace measuring system
Encoder interface defective Replace control section or complete drive controller
C0134 - Attributes
Display: C0134
Mess. no.: C0134 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-37
Cause Remedy
A motor without encoder data memory was Parameterize P-0-4014, Kind of motor correctly or
connected connect a motor with encoder data memory
Encoder defective Replace encoder
C0135 - Attributes
Display: C0135
Mess. no.: C0135 (hex)
Cause Remedy
Two encoders were detected; in their data memories Replace one of encoders by encoder without valid motor
a valid and known motor type string is contained in type string
P-0-2141, Motor type, encoder memory
Encoder connectors of neighboring axes were Check axis assignment of encoder connectors and
interchanged assign to correct axis
C0136 - Attributes
Display: C0136
Mess. no.: C0136 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-38 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Invalid motor data stored in motor data memory Replace motor or contact service department for
correction of motor data
Encoder cable defective or bad shielding Check encoder cable and shielding
Encoder memory or encoder electronics defective Replace encoder
Hardware defect on control section Replace control section or entire drive controller
C0137 - Attributes
Display: C0137
Mess. no.: C0137 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-39
Cause Remedy
Reading error from I2C-Prom due to hardware defect For detailed error diagnosis contact our service
department
C0138 - Attributes
Display: C0138
Mess. no.: C0138 (hex)
Cause Remedy
Sum of transmit starting time of master data Parameterize smaller value for transmit starting time of
telegram set by master [S-0-0089, MDT Transmit master data telegram [S-0-0089, MDT Transmit
starting time (T2)] and length of data record of starting time (T2)]
master data telegram (S-0-0010, Length of master
data telegram) exceeds SERCOS cycle time
[S-0-0002, SERCOS Cycle time (TScyc)]. This
means that master data telegram overlaps the
master synchronization telegram (MST)
C0139 - Attributes
Display: C0139
Mess. no.: C0139 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-40 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Although a linear motor is used, rotary scaling was Check and correct respective scaling parameter(s) or
selected in at least one of the following parameters: use a linear encoder
S-0-0044, Velocity data scaling type
S-0-0076, Position data scaling type
S-0-0086, Torque/force data scaling type
S-0-0160, Acceleration data scaling type
C0140 - Attributes
Display: C0140
Mess. no.: C0140 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-41
Cause Remedy
Incomplete or invalid entries in parameters for Check parameter contents and enter data supplied by
initialization of synchronous motor motor manufacturer in above parameters. If error is
generated in spite of correct data, please contact our
service department
Initialization for synchronous motor with reluctance Correct setting in P-0-4014, Kind of motor
torque was run although synchronous motor without
reluctance torque is used
C0153 - Attributes
Display: C0153
Mess. no.: C0153 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-42 Command Diagnostic Messages Rexroth IndraDrive
C0154 Field bus: IDN for cycl. command val. not configurable
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Cause Remedy
In operating data of P-0-4081, Field bus: config. In P-0-4081, Field bus: config. list of cyclic command
list of cyclic command value data ch. there is an value data ch. enter allowed IDN (cf. S-0-0188, List of
IDN that is not contained in S-0-0188, List of configurable data in the MDT)
configurable data in the MDT
C0154 - Attributes
Display: C0154
Mess. no.: C0154 (hex)
C0155 Field bus: max. length for cycl. command val. exceeded
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Cause Remedy
Sum of data widths of all IDNs entered in P-0-4081, Reduce number of IDNs entered in P-0-4081, Field
Field bus: config. list of cyclic command value bus: config. list of cyclic command value data ch.
data ch. is exceeding max. value of P-0-4071, Field
bus: length of cyclic command value data
channel
C0155 - Attributes
Display: C0155
Mess. no.: C0155 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-43
C0156 Field bus: IDN for cycl. actual val. not configurable
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Cause Remedy
In operating data of P-0-4080, Field bus: config. In P-0-4080, Field bus: config. list of cyclic command
list of cyclic command value data ch. there is an value data ch. enter allowed IDNs (cf. S-0-0187, List of
IDN that is not contained in S-0-0187, List of configurable data in the AT)
configurable data in the AT
C0156 - Attributes
Display: C0156
Mess. no.: C0156 (hex)
Cause Remedy
Sum of data widths of all IDNs entered in P-0-4080, Reduce number of IDNs entered in P-0-4080, Field
Field bus: config. list of cyclic actual value data bus: config. list of cyclic actual value data ch.
ch. is exceeding max. value of P-0-4082, Field bus:
length of cyclic actual value data channel
C0157 - Attributes
Display: C0157
Mess. no.: C0157 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-44 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
P-0-4076, Field bus: cycle time (Tcyc) is not an Adjust P-0-4076, Field bus: cycle time (Tcyc) to
integral multiple of the position loop clock position loop clock (control section ADVANCED: 500 µs
or 250 µs, control section BASIC: 500 µs)
Note: The minimum field bus cycle time [P-0-4076, Field bus: cycle
time (Tcyc)] is 500 µs for control section ADVANCED and
1000 µs for control section BASIC.
C0158 - Attributes
Display: C0158
Mess. no.: C0158 (hex)
Cause Remedy
The operating data of P-0-4081, Field bus: config. According to profile type configure one of both control
list of cyclic command value data ch. contains words in P-0-4081, Field bus: config. list of cyclic
neither P-0-4077, Field bus: control word nor command value data ch.
P-0-4068, Field bus: control word IO. At least one
control word has to be contained.
C0159 - Attributes
Display: C0159
Mess. no.: C0159 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-45
Cause Remedy
Interference caused by incorrect shielding or Check encoder cable (incl. shielding) and, if necessary,
defective encoder cable replace or run it correctly
Encoder defective Check encoder function and, if necessary, replace
encoder
Measuring encoder option on control section is Replace control section or entire drive controller
defective
Incorrect parameterization of P-0-0076, Encoder Check content of P-0-0076, Encoder type 3
type 3 (measuring encoder) (measuring encoder) and correct it in such a way that
measuring encoder is correctly assigned to optional slot
C0160 - Attributes
Display: C0160
Mess. no.: C0160 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-46 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Parameterization of P-0-0076, Encoder type 3 Correct parameterization of P-0-0076, Encoder type 3
(measuring encoder) does not match interface card (measuring encoder)
(e.g. EN1 with EnDat encoder)
P-0-0079, Assignment measuring encoder Correct parameterization of P-0-0079, Assignment
->optional slot incorrectly parameterized measuring encoder ->optional slot or change control
section configuration (replacement of control section or
drive controller)
In the case of double-axis device (CDB control Only one measuring encoder can be connected per
section) P-0-0076, Encoder type 3 (measuring double-axis device (CDB control section). P-0-0076,
encoder) was parameterized unequal "0" for both Encoder type 3 (measuring encoder) may only be
axes unequal "0" for one axis
C0161 - Attributes
Display: C0161
Mess. no.: C0161 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-47
Cause Remedy
Encoder memory (feedback) is defective Encoder must be replaced
Kind of motor encoder (P-0-1020, Kind of Check content of P-0-1020, Kind of encoder 3,
encoder 3, encoder memory) is not supported by encoder memory and contact our service department
the software
Detected kind of encoder does not match Check P-0-0079, Assignment measuring encoder
parameterized type of encoder (P-0-0079, ->optional slot and, if necessary, replace control
Assignment measuring encoder ->optional slot) section by correctly configured control section or replace
complete drive controller
C0162 - Attributes
Display: C0162
Mess. no.: C0162 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-48 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Value parameterized for P-0-0765, Modulo factor Correct content of S-0-0103, Modulo value or
measuring encoder cannot be displayed internally measuring gear settings (P-0-0127, Input revolutions
with gear that was set of measuring gear and P-0-0128, Output revolutions
of measuring gear)
P-0-0327, Encoder resolution of measuring Check and, if necessary, correct content of P-0-0327,
encoder incorrectly parameterized Encoder resolution of measuring encoder
C0163 - Attributes
Display: C0163
Mess. no.: C0163 (hex)
Cause Remedy
At least one of selected operating modes is Check and, if necessary, correct parameterization of
synchronization mode (velocity synchronization, operating mode parameters (S-0-0032, Primary mode
phase synchronization or electronic cam shaft) and of operation; S-0-0033, Secondary operation mode 1;
control encoder of synchronization mode has S-0-0034, Secondary operation mode 2;...) if
simultaneously been configured as measuring synchronization mode is not required.
encoder. This configuration is not useful. If synchronization mode is required, deactivate
measuring encoder or use additional encoder as
measuring encoder.
C0164 - Attributes
Display: C0164
Mess. no.: C0164 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-49
Cause Remedy
Parameter P-0-2003, Selection of functional Switch drive off and on again in order to accept the
packages contains functional package selection not functional package selection of P-0-2003, Selection of
corresponding to active functional package selection functional packages in P-0-2004, Active functional
(cf. P-0-2004, Active functional packages) packages
Incorrect functional package selection in P-0-2003, Set value in P-0-2003, Selection of functional
Selection of functional packages packages to value in P-0-2004, Active functional
packages
C0199 - Attributes
Display: C0199
Mess. no.: C0199 (hex)
Cause Remedy
Data block elements required in communication Write allowed operating data to respective parameters
phase 4 are missing or invalid (these parameters can be taken from list S-0-0022, IDN
list of invalid operating data for communication
phase 3).
C0201 - Attributes
Display: C0201
Mess. no.: C0201 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-50 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Parameter values required in communication Write allowed values to parameters (cf.
phase 4 are outside their allowed range of values minimum/maximum value) (these parameters can be
(minimum or maximum value) taken from list S-0-0022, IDN list of invalid operating
data for communication phase 3).
C0202 - Attributes
Display: C0202
Mess. no.: C0202 (hex)
Cause Remedy
Parameter values required in communication Write allowed values to parameters (the respective
phase 3 cannot be processed parameters can be taken from list S-0-0022, IDN list of
invalid operating data for communication phase 3).
C0203 - Attributes
Display: C0203
Mess. no.: C0203 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-51
For HMS, HMD, HCS During the execution of the command S-0-0128, C0200 Communication
phase 4 transition check an error during the initialization of amplifier
data was detected. The respective parameters are entered in the list
S-0-0022, IDN list of invalid operating data for communication
phase 3.
For HMV During the initialization of the device data error was detected.
Cause Remedy
Reading error from I2C-Prom due to hardware defect If possible, replace hardware; otherwise contact our
service department
C0212 - Attributes
Display: C0212
Mess. no.: C0212 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-52 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Motor encoder cable defective Check and if necessary replace motor encoder cable
Motor encoder defective or error in micro controller Replace motor
of measuring system
Measuring system interface defective Have measuring system interface replaced by service
department
C0220 - Attributes
Display: C0220
Mess. no.: C0220 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-53
Cause Remedy
Velocity for initialization of encoder 1 was too high Reduce velocity for encoder initialization
C0221 - Attributes
Display: C0221
Mess. no.: C0221 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-54 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Encoder cable defective Check and if necessary replace encoder cable
Encoder defective or error in micro controller of Replace encoder
measuring system
Measuring system interface defective Have measuring system interface replaced by service
department
C0224 - Attributes
Display: C0224
Mess. no.: C0224 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-55
Cause Remedy
Velocity for initialization of encoder 2 was too high Reduce velocity for encoder initialization
C0225 - Attributes
Display: C0225
Mess. no.: C0225 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-56 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Encoder cable defective Check and if necessary replace encoder cable
Interference caused by incorrect shielding Check and if necessary correct cable shielding
Encoder defective or error in micro controller of Replace encoder
measuring system
Measuring system interface defective Have measuring system interface replaced by service
department
C0227 - Attributes
Display: C0227
Mess. no.: C0227 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-57
Cause Remedy
Velocity for initialization of measuring encoder was Reduce velocity for encoder initialization
too high
C0228 - Attributes
Display: C0228
Mess. no.: C0228 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-58 Command Diagnostic Messages Rexroth IndraDrive
Remedy:
All multiple configurations are listed in parameter S-0-0022, IDN list of
invalid operating data for communication phase 3.
Each multiple configuration/each conflict is displayed in the following
form:
st
The 1 entry contains the IDN of the parameter that was configured in a
multiple way. The subsequent entries contain the IDNs of the parameters
in which the multiple-configuration parameter was configured for cyclic
parameter write. Up to 5 entries are displayed. In the IDN list, each
conflict is concluded by the IDN S-0-0000. If several conflicts occur at the
same time, they are represented one after the other in S-0-0022, IDN list
of invalid operating data for communication phase 3, being separated
by the IDN S-0-0000.
For each conflict, the configurations of the involved interfaces have to be
modified in such a way that only one interface writes data to a parameter.
C0242 - Attributes
Display: C0242
Mess. no.: C0242 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-59
Cause Remedy
Holding brake is not controlled Activate control of holding brake in P-0-0525, Holding
brake control word
P-0-0540, Torque of motor holding brake is 0 Parameterize P-0-0540, Torque of motor holding
brake correctly by means of data sheet for brake or
motor
C0243 - Attributes
Display: C0243
Mess. no.: C0243 (hex)
C0244 Act. modulo value cycle greater than max. travel range
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Cause Remedy
Calculated modulo value for actual value cycle is Check parameterization of S-0-0278, Maximum travel
greater than value parameterized in S-0-0278, range and if necessary adjust it to modulo value for
Maximum travel range actual value cycle
– or –
Check parameterization of modulo value for actual value
cycle and adjust it to S-0-0278, Maximum travel range
C0244 - Attributes
Display: C0244
Mess. no.: C0244 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-60 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Operating mode configuration is invalid (phase Parameter contents of operating mode parameters have
synchronization or electronic cam shaft with different to be changed is such a way that invalid operating mode
control encoders) configuration no longer occurs (the respective operating
mode parameters are listed in S-0-0022, IDN list of
invalid operating data for communication phase 3)
C0245 - Attributes
Display: C0245
Mess. no.: C0245 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-61
Cause Remedy
Travel range limit switches +/- have been activated Assign travel range limit switches to digital inputs via
in P-0-0090, Travel range limit parameter but not P-0-0300, Digital I/Os, assignment list
assigned to any digital input
Travel range limit switches +/- have been Deactivate travel range limit switches +/- in P-0-0090,
unintentionally activated in P-0-0090, Travel range Travel range limit parameter
limit parameter
C0246 - Attributes
Display: C0246
Mess. no.: C0246 (hex)
Cause Remedy
In the case of a double-axis device (HMD01.1), a Check parameterization of P-0-0300, Digital I/Os,
digital output is used by both axes assignment list in both axes and change it in at least
one axis
C0247 - Attributes
Display: C0247
Mess. no.: C0247 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-62 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
In the case of a double-axis device (HMD01.1), a Check parameterization of P-0-0300, Digital I/Os,
digital input was parameterized by both axes with assignment list or P-0-0301, Digital I/Os, bit numbers
different IDN (P-0-0300, Digital I/Os, assignment in both axes of double-axis device and change it in at
list) or bit number (P-0-0301, Digital I/Os, bit least one axis
numbers)
C0248 - Attributes
Display: C0248
Mess. no.: C0248 (hex)
Cause Remedy
Bit number (P-0-0301, Digital I/Os, bit numbers) for Check parameterization of P-0-0300, Digital I/Os,
an assigned IDN (P-0-0300, Digital I/Os, assignment list and P-0-0301, Digital I/Os, bit
assignment list) is not available (e.g. bit number 25 numbers and adjust P-0-0301, Digital I/Os, bit
but IDN only 2 bytes long) numbers to data format of corresponding IDN
C0249 - Attributes
Display: C0249
Mess. no.: C0249 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-63
Cause Remedy
At least one of both probes was activated in Assign probes to digital inputs via P-0-0300, Digital
S-0-0169, Probe control parameter but not I/Os, assignment list, P-0-0301, Digital I/Os, bit
assigned to any digital input numbers and P-0-0302, Digital I/Os, direction
Probes were accidentally activated Deactivate probes in S-0-0169, Probe control
parameter
C0250 - Attributes
Display: C0250
Mess. no.: C0250 (hex)
Cause Remedy
Hardware defect on control section Replace control section or entire drive controller
C0251 - Attributes
Display: C0251
Mess. no.: C0251 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-64 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Sporadic timeout error Reset optional safety technology module and contact
our service department
Firmware defect on optional safety technology If command error occurs repeatedly, safety technology
module firmware has to be replaced
Hardware defect on optional safety technology If command error occurs repeatedly, optional safety
module technology module has to be replaced
C0255 - Attributes
Display: C0255
Mess. no.: C0255 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-65
Cause Remedy
Command error occurs sporadically Restart transition command and contact our service
department
No optional encoder module available in control Replace control section with control section
section configuration containing optional encoder module
Optional encoder module with incorrect hardware Replace optional encoder module or entire drive
code or defective hardware controller and contact our service department
C0257 - Attributes
Display: C0257
Mess. no.: C0257 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-66 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
S-0-0001, NC cycle time (TNcyc) incorrectly Select appropriate S-0-0001, NC cycle time TNcyc).
parameterized Allowed NC cycle times, when using cubic fine
interpolator or fine interpolator according to contour, are:
1, 2, 3, 4, 5, 6, 7, 8 ms for S-0-0001 <= 8 ms
10, 12, 14, 16 ms for S-0-0001 <= 16 ms
20, 24, 28, 32 ms for S-0-0001 <= 32 ms
Cubic fine interpolation or fine interpolation Use linear fine interpolator (P-0-0187, Position
according to contour cannot be used with present command processing mode = 0)
NC cycle time (S-0-0001, NC cycle time TNcyc))
C0258 - Attributes
Display: C0258
Mess. no.: C0258 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-67
S − 0 − 0079 29
P − 0 − 0903 = ×2
S − 0 − 0103
S-0-0103: S-0-0103, Modulo value
P-0-0903: P-0-0903, Encoder emulation resolution
S-0-0079: S-0-0079, Rotational position resolution
S − 0 − 0079 29
P − 0 − 0903 = ×2
S − 0 − 0278
P-0-0903: P-0-0903, Encoder emulation resolution
S-0-0079: S-0-0079, Rotational position resolution
S-0-0278 S-0-0278, Maximum travel range
Cause Remedy
Resolution of emulated signal is not correct for Reduce resolution entered in P-0-0903, Encoder
modulo range / travel range emulation resolution
- or -
Reduce S-0-0278, Maximum travel range
C0260 - Attributes
Display: C0260
Mess. no.: C0260 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-68 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
The command was activated by mistake Prevent the command from being activated
The measuring system has not been parameterized Parameterize the measuring system
C0301 - Attributes
Display: C0301
Mess. no.: C0301 (hex)
Cause Remedy
The command was activated by mistake Prevent the command from being activated
The motor encoder or the optional measuring system Equip the motor or the optional measuring system with
have not been designed as absolute encoders an absolute encoder function
C0302 - Attributes
Display: C0302
Mess. no.: C0302 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-69
Remedy:
• check encoder cable and repair it, if necessary
- or -
• replace encoder
C0303 - Attributes
Display: C0303
Mess. no.: C0303 (hex)
Cause Remedy
Command for switching to parameter mode was Complete command and switch drive enable off, then
started by means of parameter P-0-4023, C0400 command can be started again
Communication phase 2 transition although drive
enable had been activated
C0401 - Attributes
Display: C0401
Mess. no.: C0401 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-70 Command Diagnostic Messages Rexroth IndraDrive
During the execution of the error clearing command (C0500) an error was
detected.
Cause:
There was an attempt to clear the F8022 Enc. 1 error: sign. amplitude
(can be cleared in ph.2) error in communication phase 4 (operating
mode). This is only possible in communication phase 2 (parameterization
mode).
Remedy:
Switch the drive in communication phase 2 by means of the P-0-4023,
C400 Communication phase 2 transition command and start the error
clearing command again.
C0501 - Attributes
Display: C0501
Mess. no.: C0501 (hex)
Remedy:
Enable the drive and start the command again.
See also Functional Description "Drive-Controlled Homing"
C0601 - Attributes
Display: C0601
Mess. no.: C0601 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-71
Remedy:
Read the value from parameter S-0-0298, Reference cam shift and take
it over to parameter S-0-0299, Home switch offset
- or -
shift the reference cam.
C0602 - Attributes
Display: C0602
Mess. no.: C0602 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-72 Command Diagnostic Messages Rexroth IndraDrive
Remedy:
First activate the P-0-0012, C0300 Command Set absolute measuring
command and then start the S-0-0148, C0600 Drive-controlled homing
procedure command. Doing this the absolute reference point is
established.
C0604 - Attributes
Display: C0604
Mess. no.: C0604 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-73
Remedy:
• check the measuring system to be homed and its cabling
• check the parameterization
• in the case of incremental measuring systems, check the reference
mark detection by executing the P-0-0014, C1400 Command Get
marker position command
C0606 - Attributes
Display: C0606
Mess. no.: C0606 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-74 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Home switch hasn’t been assigned to any digital Assign home switch (S-0-0400, Home switch) to a
input digital input via parameter P-0-0300, Digital I/Os,
assignment list
C0607 - Attributes
Display: C0607
Mess. no.: C0607 (hex)
During the execution of the C07_0 Load defaults procedure com. (load
controller param.) command an error occurred.
Cause:
The control loops, in the case of motors of the MHD, MKD and MKE
series, are adjusted to the connected digital drive by activating the
controller parameters stored in the motor encoder data memory. The
C0702 message on the display of the drive controller signals that there
isn’t any data memory available at the connected motor.
Remedy:
Data sheets of Rexroth Indramat motors are made available by the
service department. Enter the controller parameters.
C0702 - Attributes
Display: C0702
Mess. no.: C0702 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-75
During the execution of the C07_0 Load defaults procedure com. (load
controller param.) command an error occurred.
Cause:
The default parameters are read from the motor encoder data memory. At
least one of these parameters is invalid.
Remedy:
Check the connection to the motor encoder. Replace the motor, if
necessary.
See also Functional Description "Loading, Storing and Saving
Parameters"
See also Functional Description "Rexroth Housing Motors with Encoder
Data Memory"
C0703 - Attributes
Display: C0703
Mess. no.: C0703 (hex)
Cause Remedy
It was impossible to load the default values for the Load appropriate firmware version to controller; observe
motor-specific control loop parameters, available in motor type and motor encoder type
the encoder memory, to the respective parameters.
Firmware version incompatible with motor or motor
encoder
Performance and switching frequency setting do not Correct performance setting in P-0-0556, Control word
match of axis controller and switching frequency setting in
P-0-0001, Switching frequency of the power output
stage
C0704 - Attributes
Display: C0704
Mess. no.: C0704 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-76 Command Diagnostic Messages Rexroth IndraDrive
During the execution of the C07_0 Load defaults procedure com. (load
controller param.) command an error occurred when reading the
controller parameters from the feedback.
Cause:
Feedback defective
Remedy:
Replace feedback
C0706 - Attributes
Display: C0706
Mess. no.: C0706 (hex)
C0722 - Attributes
Display: C0722
Mess. no.: C0722 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-77
With the command C07_2 Load def. proc. com. (load def. pr. for
safety techn.) the safety parameters of channel 1 are set to default
values and an internal command is started so that channel 2 accepts the
default values. The safety technology is deactivated by the command
because valid safety parameters are no longer available. The safety
technology is in its condition as supplied.
Cause Remedy
Internal command for channel 2 was incorrectly Clear command C07_2 Load def. proc. com. (load def.
executed pr. for safety techn.) and then restart it.
If error is signaled again, reset optional safety
technology module (switch control voltage off and then
on again)
Channel 2 is executing another internal command Complete internal command that is still running
that mustn’t be interrupted
Hardware defect on optional safety technology Restart C07_2 Load def. proc. com. (load def. pr. for
module safety techn.). If command error occurs repeatedly,
replace control section or entire drive controller
C0723 - Attributes
Display: C0723
Mess. no.: C0723 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-78 Command Diagnostic Messages Rexroth IndraDrive
Within the command C07_2 Load def. proc. com. (load def. pr. for
safety techn.) an internal command for the safety technology channel 2
was started. The internal command was aborted with timeout.
Note: The command C07_2 Load def. proc. com. (load def. pr. for
safety techn.) is started by parameter S-0-0262, C07_x Load
defaults procedure command with the respective setting in
P-0-4090, Index for C07 Load defaults procedure.
Cause Remedy
Sporadic timeout error Reset optional safety technology module (switch control
voltage off and then on again). Restart C07_2 Load def.
proc. com. (load def. pr. for safety techn.). If the
command error occurs repeatedly, contact our service
department
Firmware defect on optional safety technology Restart C07_2 Load def. proc. com. (load def. pr. for
module safety techn.). If command error occurs repeatedly,
safety technology firmware has to be replaced
Hardware defect on optional safety technology Restart C07_2 Load def. proc. com. (load def. pr. for
module safety techn.). If command error occurs repeatedly,
replace control section or entire drive controller
C0724 - Attributes
Display: C0724
Mess. no.: C0724 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-79
C0751 - Attributes
Display: C0751
Mess. no.: C0751 (hex)
During the execution of the C07_1 Load defaults procedure com. (load
basic parameters) command an error occurred.
Cause:
The drive parameters were write-protected by means of the S-0-0267,
Password parameter. The C0752 diagnostic message signals that the
C07_1 Load defaults procedure com. (load basic parameters)
command was started without first deactivating the customer password.
Remedy:
Deactivate the write protection by entering the password. Start the
command again.
See also Functional Description "Using a Password"
C0752 - Attributes
Display: C0752
Mess. no.: C0752 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-80 Command Diagnostic Messages Rexroth IndraDrive
C0799 - Attributes
Display: C0799
Mess. no.: C0799 (hex)
Note: This command error can only occur as a result of the C0800
Load basic parameters command that can only be used by
the manufacturer!
C0851 - Attributes
Display: C0851
Mess. no.: C0851 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-81
Note: This command error can only occur as a result of the C0800
Load basic parameters command that can only be used by
the manufacturer!
C0852 - Attributes
Display: C0852
Mess. no.: C0852 (hex)
Remedy:
Set drive enable before starting the command.
C0902 - Attributes
Display: C0902
Mess. no.: C0902 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-82 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
At start of S-0-0152, C0900 Position spindle In the case of incremental measuring systems, check
command, respective encoder had not yet been whether S-0-0400, Home switch was assigned to a
initialized (homed) digital input. Assignment, connection and function of
home switch must have been realized (only when home
switch is evaluated)!
C0903 - Attributes
Display: C0903
Mess. no.: C0903 (hex)
Remedy:
• Check parameterization of spindle positioning and of drive-controlled
homing procedure, especially encoder and home switch combination
used.
• Check encoder parameterization.
• Check distance zero pulse - home switch.
• Carry out drive-controlled homing in order to check homing procedure.
C0906 - Attributes
Display: C0906
Mess. no.: C0906 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-83
C1204 - Attributes
Display: C1204
Mess. no.: C1204 (hex)
C1208 - Attributes
Display: C1208
Mess. no.: C1208 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-84 Command Diagnostic Messages Rexroth IndraDrive
Remedy:
Switch the drive controller to phase 4 and execute the command
P-0-0524, C1200 Commutation offset setting command again.
C1209 - Attributes
Display: C1209
Mess. no.: C1209 (hex)
C1211 - Attributes
Display: C1211
Mess. no.: C1211 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-85
Cause Remedy
The connected motor is not a synchronous linear -
motor
The connected motor is a synchronous linear motor, If the connected motor is a synchronous linear motor
but the wrong motor type (P-0-4014) was selected with absolute measuring system, check the motor type
or the pole pair distance (P-0-0018) was set to "0" that has been set (P-0-4014) and correct it, if necessary
The connected motor is a synchronous linear motor, If the connected motor is a synchronous linear motor
the motor type (P-0-4014) was correctly set, but with incremental measuring system or a rotary
there isn’t any absolute encoder with EnDat interface synchronous motor, then use the procedure with current
available to determine the commutation offset (see P-0-0522,
Control word for commutation setting)
C1214 - Attributes
Display: C1214
Mess. no.: C1214 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-86 Command Diagnostic Messages Rexroth IndraDrive
Remedy:
Bring the drive to the ready for operation status ("bb")
C1215 - Attributes
Display: C1215
Mess. no.: C1215 (hex)
Remedy:
Set a mode for commutation determination in the P-0-0522,
Commutation setting control word parameter.
C1216 - Attributes
Display: C1216
Mess. no.: C1216 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-87
Cause Remedy
The drive was not ready at the start of the command, 1. Switch drive to communication phase 4, if there isn’t
the display did not read "Ab" any error present the display reads "bb"
("betriebsbereit" = ready for operation)
2. Switch power on, drive goes to operating mode, the
display reads "Ab" ("Antrieb bereit" = drive ready)
3. Now start command C1200
C1217 - Attributes
Display: C1217
Mess. no.: C1217 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-88 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Actual current value amplitude is not sufficient for Increase signal voltage (P-0-0506, Amplitude for angle
exact determination of commutation offset acquisition) or reduce signal frequency (P-0-0507, Test
frequency for angle acquisition) and restart
commutation setting process
- or -
Enter value "0" in P-0-0506, Amplitude for angle
acquisition. Appropriate value for P-0-0506 is thereby
automatically determined during commutation setting
process
- or -
Reduce value of P-0-0517, Commutation: required
harmonics component, if approx. 30 similar values are
determined for P-0-0521, Effective commutation
offset with repeated commutation setting for different
motor positions (drive remains in "Ab"). Reduce
P-0-0517, Commutation: required harmonics
component until command error C1218 no longer
occurs; finally check function several times!
C1218 - Attributes
Display: C1218
Mess. no.: C1218 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-89
Remedy:
Reduce the signal voltage (P-0-0506, Voltage amplitude for angle
acquisition) or increase the signal frequency (P-0-0507, Test frequency
for angle acquisition).
- or -
With P-0-0506 = 0 start the automatic determination of appropriate
values.
C1219 - Attributes
Display: C1219
Mess. no.: C1219 (hex)
Remedy:
Switch the drive off and on again. If the error continues to be signaled,
contact the service department.
C1220 - Attributes
Display: C1220
Mess. no.: C1220 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-90 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Type current of controller too low Use controller that can supply motor with sufficiently
high current (for Rexroth kit motors, required minimum
current for magnetic saturation effects is approx.
2.0...2.5-fold continuous current at standstill).
If without success, check whether sine-wave method
can be used for commutation offset setting
Test current generated in motor is too low Manually increase value of P-0-0506, Amplitude for
angle acquisition or reduce value of P-0-0507, Test
frequency for angle acquisition so that higher test
current is generated.
If without success, check whether sine-wave method
can be used for commutation offset setting
C1221 - Attributes
Display: C1221
Mess. no.: C1221 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-91
Remedy:
• execute the C1200 command again
• check wiring for noise immunity
• replace sensor of the encoder
• contact our service department, if necessary
C1222 - Attributes
Display: C1222
Mess. no.: C1222 (hex)
C1301 - Attributes
Display: C1301
Mess. no.: C1301 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-92 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
There aren’t two encoders available Connect measuring wheel encoder
C1701 - Attributes
Display: C1701
Mess. no.: C1701 (hex)
In order to make sure that the drive is in control when the command
P-0-0162, C1800 Command Automatic control loop adjust is started,
this is queried at the start of the command.
Cause Remedy
Drive enable not set at start of command Set drive enable and restart command P-0-0162, C1800
Command Automatic control loop adjust
C1801 - Attributes
Display: C1801
Mess. no.: C1801 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-93
Remedy:
If known, write correct values back to encoder data memory or contact
Rexroth service department in order to get data valid for respective motor.
If it is impossible to correct parameter values in encoder data memory,
motor must be replaced!
See also Functional Description "Automatic Setting of Axis Control"
C1802 - Attributes
Display: C1802
Mess. no.: C1802 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-94 Command Diagnostic Messages Rexroth IndraDrive
At the beginning of the automatic control loop setting the mass inertia is
determined by a "pendulum test".
This means that the speed change and motor current during acceleration
or deceleration have to exceed certain minimum values in order to
guarantee useful and sufficiently exact calculation of the inertia.
Causes:
• drive acceleration too low
• load inertia too high
• motor speed too low
• not enough measured values for automatic control loop setting
Remedies:
• increase S-0-0260, Positioning acceleration
• increase S-0-0092, Bipolar torque/force limit value
• increase S-0-0259, Positioning Velocity
• increase S-0-0108, Feedrate override
See also Functional Description "Prerequisites for Starting the Automatic
Control Loop Setting"
C1803 - Attributes
Display: C1803
Mess. no.: C1803 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-95
Remedy:
It is sometimes possible to achieve a satisfactory result by restarting the
command P-0-0162, C1800 Command Automatic control loop adjust
with a high P-0-0163, Damping factor for autom. controller adjust, i.e.
a low degree of dynamic response.
This value then can still be reduced until the desired control loop behavior
occurs.
See also Functional Description "Automatic Setting of Axis Control"
C1804 - Attributes
Display: C1804
Mess. no.: C1804 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-96 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Maximum travel distance (P-0-0169, Travel 1. Clear command error by completing the command
distance for autom. controller adjust) defined with 2. Define limits again so that defined travel range is
P-0-0166, Lower position limit for autom. control bigger
loop adjust and P-0-0167, Upper position limit for 3. Restart command with useful travel range
autom. control loop adjust is smaller than 6 motor
revolutions and therefore too small in order to be
able to start automatic control loop setting.
C1805 - Attributes
Display: C1805
Mess. no.: C1805 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-97
During the automatic control loop setting the travel range limits P-0-0166,
Lower limit for autom. control loop adjust and P-0-0167, Upper limit
for autom. control loop adjust are permanently monitored.
If one of these limits is exceeded, the command error C1806 is output
and the drive is shut down in a speed-controlled way.
Cause Remedy
Actual position is outside defined travel range 1. Clear command error by completing the command
- or – 2. Define limits again so that actual position is within
Limits were defined again after start of command defined travel range
3. Restart command with useful travel range
C1806 - Attributes
Display: C1806
Mess. no.: C1806 (hex)
When parameterizing the travel range for the automatic control loop
setting the modulo scaling was not taken into account.
Cause Remedy
There was an attempt to parameterize travel range Define travel range by parameterizing P-0-0169, Travel
via P-0-0166, Lower limit for autom. control loop distance for autom. controller adjust
adjust / P-0-0167, Upper limit for autom. control
loop adjust. In this case travel range can only be
parameterized directly
C1807 - Attributes
Display: C1807
Mess. no.: C1807 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-98 Command Diagnostic Messages Rexroth IndraDrive
Remedy:
Set bit 5 in parameter P-0-0525 to "allowed".
See also Functional Description "Motor Holding Brake"
C2001 - Attributes
Display: C2001
Mess. no.: C2001 (hex)
Remedy:
Switch drive to "AF" ("Antriebsfreigabe" = drive enable), then start the
C2100 command.
See also Functional Description "Motor Holding Brake"
C2101 - Attributes
Display: C2101
Mess. no.: C2101 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-99
When executing the "brake check" command (C2100) the holding torque
of the brake was detected to be too low.
The command C2100 is aborted if the "abrasion" of the brake was
deactivated via bit 4 in P-0-0525, Holding brake control word.
Otherwise the drive tries to reestablish the brake torque by automatically
starting the abrasion cleaning process and then checks the holding torque
again.
Cause:
Due to storage brake is covered with an oxide layer.
- or -
Brake is wetted with oil or grease.
- or -
Brake is worn.
Remedy:
Start "Brake check" command again in order to reestablish full brake
torque by repeated abrasion.
If brake torque is still too low after several attempts to reestablish it, brake
or motor must be replaced.
See also Functional Description "Motor Holding Brake"
C2103 - Attributes
Display: C2103
Mess. no.: C2103 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-100 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
in the P-0-0525, Holding brake control word activate the brake in the P-0-0525, Holding brake
parameter the brake has not been activated control word parameter
the value in P-0-0540, Torque of motor brake is 0 enter the correct value for P-0-0540, Torque of motor
brake
C2104 - Attributes
Display: C2104
Mess. no.: C2104 (hex)
Remedy:
• First start the command S-0-0264, C2200 Backup working memory
procedure command again. If the error occurs again, then
• replace MMC (if plugged in) if necessary, then start the command
again. If the error occurs again,
• contact the service department.
C2202 - Attributes
Display: C2202
Mess. no.: C2202 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-101
Remedy:
Restart the command. If the error occurs again contact the service
department. Have the control section checked for functional safety.
C2301 - Attributes
Display: C2301
Mess. no.: C2301 (hex)
Remedy:
Enter the faulty parameter values correctly by hand and save them again
in the non-volatile memory.
C2302 - Attributes
Display: C2302
Mess. no.: C2302 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-102 Command Diagnostic Messages Rexroth IndraDrive
Remedy:
• Start the S-0-0293, C2400 Selectively backup working memory
procedure command again. If the error occurs again, then
• replace MMC (if plugged in) if necessary, then start the command
again. If the error occurs again,
• contact the service department.
C2402 - Attributes
Display: C2402
Mess. no.: C2402 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-103
Note: The MMC can only be used as an optional memory for control
sections with MMC slot.
Cause Remedy
MMC had not been active before, there haven’t been Write parameter contents of internal memory to MMC by
any valid parameter contents stored on it executing command P-0-4092, C2600 Copy IDN from
internal memory to optional memory
MMC has not (or not completely) been plugged in Put MMC into controller. Then restart command
the MMC slot provided for this purpose P-0-4091, C2500 Copy IDN from optional memory to
internal memory
Error occurs sporadically due to voltage fluctuations Check power supply and then restart command
in device P-0-4091, C2500 Copy IDN from optional memory to
internal memory.
If error occurs repeatedly, you should contact our
service department
MMC was not or not correctly formatted Format MMC or contact our service department. Then
restart command P-0-4091, C2500 Copy IDN from
optional memory to internal memory
MMC is defective Check MMC and restart command P-0-4091, C2500
Copy IDN from optional memory to internal memory.
If diagnostic message appears repeatedly: replace MMC
MMC slot in control section is defective Check MMC slot and, if necessary, replace control
section or complete drive controller
Note: If the MMC must be replaced, the values stored on it are lost.
C2502 - Attributes
Display: C2502
Mess. no.: C2502 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-104 Command Diagnostic Messages Rexroth IndraDrive
During the execution of the P-0-4091, C2500 Copy IDN from optional
memory to internal memory an error occurred.
Cause Remedy
Error when writing to the internal, non-volatile flash Start the P-0-4091, C2500 Copy IDN from optional
memory memory to internal memory again.
If the diagnostic message is displayed repeatedly:
contact the service department
C2504 - Attributes
Display: C2504
Mess. no.: C2504 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-105
During the execution of the command P-0-4092, C2600 Copy IDN from
internal memory to optional memory a check is run in order to find out
whether a functioning MMC (MultiMediaCard) is available.
Note: The MMC can only be used as an optional memory for control
sections with MMC slot.
Cause Remedy
MMC has not (or not completely) been plugged in Put MMC into controller. Then restart command
the MMC slot provided for this purpose P-0-4092, C2600 Copy IDN from internal memory to
optional memory
MMC was not or not correctly formatted Format MMC or contact our service department. Then
restart command P-0-4092, C2600 Copy IDN from
internal memory to optional memory
MMC is defective Check MMC and restart command P-0-4092, C2600
Copy IDN from internal memory to optional memory.
If diagnostic message appears repeatedly: replace MMC
MMC slot in control section is defective Check MMC slot and, if necessary, replace control
section or complete drive controller
Note: If the MMC must be replaced, the values stored on it are lost.
C2602 - Attributes
Display: C2602
Mess. no.: C2602 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-106 Command Diagnostic Messages Rexroth IndraDrive
During the execution of the P-0-4092, C2600 Copy IDN from internal
memory to optional memory an error occurred.
Cause Remedy
Error when reading the internal flash memory Start the P-0-4092, C2600 Copy IDN from internal
memory to optional memory again.
If the diagnostic message is displayed repeatedly: save
the parameter values via the serial interface or the
SERCOS interface, if required. In the medium term,
have the control section checked for functional safety
C2604 - Attributes
Display: C2604
Mess. no.: C2604 (hex)
Cause Remedy
During gain adjust, reference voltage was used Check input signal used for precision; if necessary, use
that fluctuates by more that 1% of input voltage different calibration signal
range
During zero point adjust, input voltage is not Short circuit analog inputs by means of wire bridge
exactly "0" and fluctuates by more than 1% of
input voltage range
C2802 - Attributes
Display: C2802
Mess. no.: C2802 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-107
Cause Remedy
During zero point and gain adjust, the same Voltage provided at input has to be modified between
voltage value was provided at analog input two steps of adjust (voltage value for zero adjust: 0 V,
voltage value for gain adjust: maximum input voltage)
C2803 - Attributes
Display: C2803
Mess. no.: C2803 (hex)
C2804 - Attributes
Display: C2804
Mess. no.: C2804 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-108 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
A transmission error occurred during transmission Execute P-0-4072, C2900 Command Firmware update
of firmware from MMC from MMC again.
If error occurs again, contact a Rexroth service engineer
Firmware file (ibf file) available on MMC is not Use different MMC with firmware file appropriate for
correct (does not match control section) control section
– control section CSH01.1C: firmware MPH
– control section CSB01.1x: firmware MPB
– control section CDB01.1x: firmware MPD
C2903 - Attributes
Display: C2903
Mess. no.: C2903 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-109
Cause Remedy
Due to voltage fluctuations in device an active Execute P-0-4072, C2900 Command Firmware update
request was aborted from MMC again
Control section is defective Replace control section or entire drive controller
C2904 - Attributes
Display: C2904
Mess. no.: C2904 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-110 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Firmware transfer from MMC was incorrect Execute P-0-4072, C2900 Command Firmware update
from MMC again
Firmware available on MMC is not correct Use a different MMC with the desired firmware
An error was detected during check of flash Execute P-0-4072, C2900 Command Firmware update
from MMC again.
If error occurs repeatedly, replace control section or
entire drive controller
C2905 - Attributes
Display: C2905
Mess. no.: C2905 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-111
Cause Remedy
Another safety technology command is still active, Wait until active command has been completed and
e.g. C07_2 Load defaults procedure command (load restart command P-0-3204, C3000 Synchronize and
defaults procedure for safety technology) or safety store safety technology IDN command
technology password writing
Hardware defect of optional module "safety Reset optional module "safety technology I/O" by a
technology I/O" restart. If command error occurs repeatedly, hardware
has to be replaced
C3001 - Attributes
Display: C3001
Mess. no.: C3001 (hex)
C3101 Act. modulo value cycle greater than max. travel range
Supported by Firmware Variant: FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
C3101 - Attributes
Display: C3101
Mess. no.: C3101 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-112 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Drive enable has been set and command P-0-0071, To be able to carry out the command, drive enable has
C3100 Recalculate actual value cycle was started to be removed
C3102 - Attributes
Display: C3102
Mess. no.: C3102 (hex)
Cause Remedy
List element 1 (rated current) in P-0-4032, Type Value for rated current has to be inside of following
plate list asynchronous motor is outside of useful limits:
limits rated current > 0.01 * amplifier peak current
and
rated current < 10 * amplifier peak current
C3201 - Attributes
Display: C3201
Mess. no.: C3201 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-113
Cause Remedy
List element 2 (rated voltage) in P-0-4032, Type Value for rated voltage has to be between 10 V and
plate list asynchronous motor is outside of useful 2000 V
limits
C3202 - Attributes
Display: C3202
Mess. no.: C3202 (hex)
Cause Remedy
List element 3 (rated frequency) in P-0-4032, Type Value for rated frequency has to be between 5 Hz and
plate list asynchronous motor is outside of useful 3000 Hz
limits
C3203 - Attributes
Display: C3203
Mess. no.: C3203 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-114 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
There is no useful relation between list element 4 Correct list element 4 (rated speed) in P-0-4032, Type
(rated speed) in P-0-4032, Type plate list plate list asynchronous motor
asynchronous motor and rated frequency, i.e.
number of pole pairs cannot be calculated
C3204 - Attributes
Display: C3204
Mess. no.: C3204 (hex)
Cause Remedy
Power factor of motor is outside of useful limits List element 5 (power factor cos LQP-0-4032, Type
plate list asynchronous motor has to be between 0.5
and 0.999
C3205 - Attributes
Display: C3205
Mess. no.: C3205 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-115
Remedy:
Correct values in P-0-4032, Type plate list asynchronous motor and
restart command P-0-4033, C3200 Command Calculate data for
asynchronous motor.
C3206 - Attributes
Display: C3206
Mess. no.: C3206 (hex)
Cause Remedy
List length of parameter P-0-4032, Type plate list Please check: To calculate motor and controller
asynchronous motor is shorter than 6 elements or parameters from type plate of an asynchronous motor,
at least one element has value "0" value higher than "0" has to be entered in all 6 list
elements of P-0-4032, Type plate list asynchronous
motor
C3207 - Attributes
Display: C3207
Mess. no.: C3207 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-116 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
At least one list element in P-0-4032, Type plate list Correct values in P-0-4032, Type plate list
asynchronous motor has no useful value so that at asynchronous motor and restart command P-0-4033,
least one parameter is outside of allowed limits when C3200 Command Calculate data for asynchronous
motor data are calculated motor
C3208 - Attributes
Display: C3208
Mess. no.: C3208 (hex)
Cause Remedy
Acquisition velocity outside of allowed range of Check range of values for acquisition velocity (range of
values values relates to encoder shaft or sensor head)
C3501 - Attributes
Display: C3501
Mess. no.: C3501 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-117
Cause Remedy
Motor encoder does not supply any signal or is not Check whether signals of motor encoder are reaching
recognized by controller controller. If necessary, replace motor encoder or motor
encoder cable
Motor encoder not available, not connected or not Connect motor encoder and register it in P-0-0074,
registered ("open-loop" operation) Encoder type 1 (motor encoder)
C3502 - Attributes
Display: C3502
Mess. no.: C3502 (hex)
Cause Remedy
Optional encoder does not supply any signal or is Check whether signals of optional encoder are reaching
not recognized by controller controller. If necessary, replace encoder or encoder
cable
Optional encoder not available, not connected or not Connect optional encoder and register it in P-0-0075,
registered Encoder type 2 (optional encoder)
C3503 - Attributes
Display: C3503
Mess. no.: C3503 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-118 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Measuring encoder does not supply any signal or is Check whether signals of measuring encoder are
not recognized by controller reaching controller. If necessary, replace encoder or
encoder cable
Measuring encoder not available, not connected or Connect measuring encoder and register it in P-0-0076,
not registered Encoder type 3 (measuring encoder)
C3504 - Attributes
Display: C3504
Mess. no.: C3504 (hex)
Cause Remedy
At start of command P-0-0340, C3500 Command Select encoder in P-0-0341, Control word for encoder
Determine encoder correction values there hadn’t correction
any encoder been selected in P-0-0341, Control
word for encoder correction
C3505 - Attributes
Display: C3505
Mess. no.: C3505 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-119
Cause Remedy
Determined correction value table (P-0-0342, Execute command P-0-0340, C3500 Command
Correction value table for encoder correction) is Determine encoder correction values again, select
incomplete different acquisition velocity
Due to hardware problem, determined correction Replace device
value table (P-0-0342, Correction value table for
encoder correction) cannot be stored in drive
C3506 - Attributes
Display: C3506
Mess. no.: C3506 (hex)
The command C3700 Manually unlocking the safety door was not or
incorrectly executed.
Cause Remedy
Drive still is in normal operation, there hasn’t been Clear command C3700 Manually unlocking the safety
any safety function activated yet door. Select safety function via operating mode switch
Error in command processing (time exceeded) Switch control voltage of controller off and on. Execute
command C3700 Manually unlocking the safety door
again. If error is displayed again: replace controller
Command was started with safety function being Clear command C3700 Manually unlocking the safety
active, but requirements for command execution are door
missing
C3701 - Attributes
Display: C3701
Mess. no.: C3701 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-120 Command Diagnostic Messages Rexroth IndraDrive
Cause Remedy
Command was activated without drive enable ("AF") Switch drive to "AF", then start command P-0-0544,
having been set C3900 Command Abrasion of brake
C3901 - Attributes
Display: C3901
Mess. no.: C3901 (hex)
Cause Remedy
Torque of the amplifier is reduced Remove reduction
Axis is mechanically blocked Remove mechanical blocking
Axis is at end stop or runs towards it Choose axis position such that sufficient motion is
possible
Abrasion of brake is impossible because motor Check whether there are torque limitations active in
generates less torque than holding torque of brake drive or whether controller was sufficiently dimensioned
Sum of weight load and brake torque is greater than Reduce weight load, if possible
motor peak torque
C3902 - Attributes
Display: C3902
Mess. no.: C3902 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Command Diagnostic Messages 9-121
Cause Remedy
Brake control has not been activated in parameter Activate brake control in parameter P-0-0525, Holding
P-0-0525, Holding brake control word brake control word
Value in P-0-0540, Torque of motor holding brake Enter correct value for P-0-0540, Torque of motor
is 0 holding brake
C3903 - Attributes
Display: C3903
Mess. no.: C3903 (hex)
Cause Remedy
There hasn’t been any home switch configured Configure a home switch in P-0-3211, Safety
technology I/O control word, channel 2
Maximum allowed deviation of actual position Check parameterization of P-0-3229, Tolerance
values 1 and 2 was exceeded during command window for safety related homing procedure; comply
execution with parameterized tolerance window during command
execution
Note: If necessary, reset the module (switch control voltage off and
then on again) in addition to trouble shooting.
C4001 - Attributes
Display: C4001
Mess. no.: C4001 (hex)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
9-122 Command Diagnostic Messages Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-1
XX: DL
Brief Description: Download -> Shutdown carried out successfully
A shutdown was carried out.
FL: DL: The firmware loader is active.
LD: DL: The loader in the control section is active.
Note: You can only exit the shutdown mode by rebooting (requested
via the master communication or by switching the drive off).
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-2 Handling, Diagnostic and Service Functions Rexroth IndraDrive
XX:ERASE
Brief Description: Clearing active
The loader (FL:ERASE = firmware loader, LD:ERASE = loader in control
section) is in the clearing mode. The requested memory range / module is
being cleared.
XX: PROG
Brief Description: Programming active
The loader (FL:PROG = firmware loader, LD:PROG = loader in control
section) is in the programming mode. The transmitted data are written to
the requested address in the memory range / module.
XX: CKS
Brief Description: Checksum calculation active
The checksum calculation is active. Subsequent to the calculation a
comparison with the stored checksums is run.
Note: "FL: CKS" means firmware loader and "LD: CKS" means
loader in control section.
XX:E ADR
Brief Description: Warning: address error
Cause Remedy
Address read from IBF file is outside of allowed Please contact our service department
range
Note: "FL:E ADR" means firmware loader and "LD:E ADR" means
loader in control section.
XX:E SEC
Brief Description: Warning: range error
Cause Remedy
Data in IBF concerning memory range (firmware, Please contact our service department
loader, boot kernel) are incorrect
Note: "FL: SEC" means firmware loader and "LD: SEC" means
loader in control section.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-3
XX:E FW
Brief Description: Warning: no valid firmware available
Cause Remedy
Firmware module contained in internal memory is Carry out firmware update (by means of "Dolfi" program
defective, therefore clearing of loader is impossible or by starting command P-0-4072, C2900 Command
Firmware update from MMC)
Note: "FL:E FW" means firmware loader and "LD:E FW" means
loader in control section.
XX:E LD
Brief Description: Warning: no valid loader available
Cause Remedy
Firmware module contained in internal memory is Carry out firmware update (by means of "Dolfi" program
defective, therefore clearing of loader is impossible or by starting command P-0-4072, C2900 Command
Firmware update from MMC)
Note: "FL:E LD" means firmware loader and "LD:E LD" means
loader in control section.
XX:E SEQ
Brief Description: Warning: sequence error
Cause Remedy
Command order was not complied with when drive Use auxiliary program "Dolfi" or command P-0-4072,
firmware was programmed C2900 Command Firmware update from MMC for
firmware update
– or –
Carry out shutdown before clearing or programming
drive firmware
You tried to write to a range with valid checksum Before writing, clear range to which data are to be
written
Note: "FL:E SEQ" means firmware loader and "LD:E SEQ" means
loader in control section.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-4 Handling, Diagnostic and Service Functions Rexroth IndraDrive
XX:F9002
Brief Description: Error: operating system error
See F9002 Error internal RTOS function call
XX:F2100
Brief Description: Error: internal memory defective
See F2100 Incorrect access to command value memory
XX:F CKS
Brief Description: Error: checksum error
Cause Remedy
Checksums of programmed modules are calculated Carry out firmware update again; should error occur
after firmware update. Calculated and entered again, please contact our service department
checksums were detected to be different
Note: "FL:F CKS" means firmware loader and "LD:F CKS" means
loader in control section.
XX:F ACC
Brief Description: Error: access error
Cause Remedy
Several possibilities of firmware update (serial and Restart firmware update using only one possibility (serial
MMC) were used simultaneously. An access or MMC)
conflict has occurred
Note: "FL:F ACC" means firmware loader and "LD:F ACC" means
loader in control section.
XX:F2101
Brief Description: Error: MMC defective
See F2101 It was impossible to address MMC
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-5
XX:F8122
Brief Description: Error: control section defective
An error occurred during firmware update.
Cause Remedy
Hardware of control section is defective Replace control section or entire drive controller; use
hardware configuration of same type
XX:F8129
Brief Description: Error: optional safety module 1 incorrectly
programmed
See F8129 Firmware of option 1 of safety technology defective
XX:F8130
Brief Description: Error: optional safety module 2 incorrectly
programmed
See F8130 Firmware of option 2 of safety technology defective
XX:F8120
Brief Description: Error: firmware does not support hardware
See F8120 Invalid control section/firmware combination
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-6 Handling, Diagnostic and Service Functions Rexroth IndraDrive
Supply Units
The concept of Rexroth supply units includes safe, quick and
uncomplicated replacement of devices. This allows reducing production
downtimes, caused by failures of these devices, to a minimum.
Failures in the supply unit are displayed by means of diagnostic
messages. According to the diagnostic error message, the measure
"replacing the supply unit" can be indicated.
Fill Out Fault Report A fault report form to be copied can be found in the documentation of the
respective supply unit. Please copy this fault report, fill it out carefully and
completely and enclose it to the defective device! The fault report filled
out completely supports quick handling of repair and helps recognizing
application-related failure causes.
Replace Supply Unit De-energize drive system; wait for DC bus to discharge!
Note: Notes on how to mount and dismount the supply unit see
documentation of the respective supply unit
Put Drive System into Operation Put machine into operation again according to machine manufacturer’s
Again instructions!
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-7
Drive Controllers
The concept of Rexroth controllers includes safe, quick and
uncomplicated replacement of devices. This allows reducing production
downtimes, caused by failures of these devices, to a minimum.
Failures in the drive controller are displayed by means of diagnostic
messages. According to the diagnostic error message, the measure
"replacing the controller" can be indicated.
The sequence of the replacement of devices is described in the
documentation "Project Planning Manual for Power Section".
The type designations can be seen on the adhesive labels at the power
section and control section (see also documentation for the respective
device component).
The firmware type active in the device can be shown on the display of the
control panel.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-8 Handling, Diagnostic and Service Functions Rexroth IndraDrive
Fill Out Fault Report A fault report form to be copied can be found in the documentation
"Project Planning Manual for Power Section or Control Section". Please
copy this fault report, fill it out carefully and completely and enclose it to
the defective device! The fault report filled out completely supports quick
handling of repair and helps recognizing application-related failure
causes.
Put Controller Into Ready-For- Put machine into ready-for-operation status again according to machine
Operation Status Again manufacturer’s instructions; then switch on control voltage!
Depending on the previous configuration of the replacement device, the
following messages can appear during the booting phase:
Firmware Download • "Firmware update?"
Acknowledge this message by pressing the "Enter" button of the control
panel. The firmware download is then running, the respective messages
are appearing.
The drive then is in the booting phase again and the display reads:
Loading Parameter Values • "Load new Param.?"
Acknowledge the message by pressing the "Enter" button of the control
panel. The drive then completes the booting phase and in communication
phase "P1" waits for further actions of the control master.
Note: The drive is now running again with the same firmware and
the same parameter values as before the device was
replaced. The absolute position data reference of measuring
systems is maintained!
When the MMC was not plugged in the controller before the control
voltage is switched on, the following message is displayed:
• "Load new Param.?".
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-9
In this case switch the control voltage off, plug the MMC of the defective
device in the replacement device and then switch the control voltage on
again.
Note: The message "Load new Param.?" does not always appear
when the MMC hasn’t been plugged (depending on the
previous configuration of the replacement device)!
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-10 Handling, Diagnostic and Service Functions Rexroth IndraDrive
Put Controller Into Ready-For- Put machine into ready-for-operation status again according to machine
Operation Status Again manufacturer’s instructions; then switch on control voltage!
Depending on the previous configuration of the replacement device, the
following message can appear during the booting phase:
• "Load new Param.?"
Acknowledge this message by pressing the "Enter" button of the control
panel. The drive then completes the booting phase and in communication
phase "P1" waits for further actions of the control master.
Load Firmware First load the same firmware as installed before replacing the device to
the replacement device (if it is not already available there). The firmware
can be loaded via:
• Control panel of the controller with temporarily plugged MMC
("hot plug")
Note: The MMC may only be plugged in its slot at the device when
the booting process has been completed (communication
phase > "P1"). Otherwise it is possible that axis-specific drive
parameters are overwritten with incorrect values!
Load Parameter Values The axis-specific parameter values saved before replacing the device can
(Saved Before Replacing Device) be loaded via:
• Control panel of the controller with temporarily plugged MMC
("hot plug")
By pressing the buttons on the control panel in a certain order the
command C2500 Copy IDN from optional memory to internal
memory (P-0-4091) can be started. By doing this the parameter
values stored on the MMC [according to S-0-0192, IDN-list of backup
operation data and P-0-0195, IDN list of retain data (replacement
of devices)] are loaded to the internal flash memory.
• "DriveTop" commissioning tool
By selecting the respective menu item, the parameter values stored on
an external data carrier (hard disk, floppy disk or the like), immediately
before the device was replaced, according to lists S-0-0192 and
P-0-0195 are loaded to the controller (serial communication with the
controller or via SYSDA/SERCOS interface).
• Control master
The parameter values saved immediately before the replacement of
the device on a master-side data carrier (according to list parameters
S-0-0192 and P-0-0195) are loaded to the controller by the control
master.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-11
Load Parameter Values in Case If it should have been impossible to save the parameter values according
of Total Breakdown of Device to the list parameters S-0-0192 and P-0-0195 immediately before
replacing the device (total breakdown of device), the parameter values
saved after initial commissioning have to be loaded.
Note: In the case of drives with absolute value encoder and modulo
format, the position data reference has to be established again
after having loaded the parameter values saved after initial
commissioning, even if the actual position values are signaled
to be valid via S-0-0403, Position feedback value status!
Control Section
IndraDrive controllers are delivered completely with the control section
and should be replaced completely, too. Only Bosch Rexroth service
engineers or especially trained users are allowed to replace the control
section separately.
Optional Modules
Only service engineers are allowed to replace optional modules of the
control section.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-12 Handling, Diagnostic and Service Functions Rexroth IndraDrive
• Replace motor.
Replacing Cables
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-13
• Replace cables.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-14 Handling, Diagnostic and Service Functions Rexroth IndraDrive
This fault report is intended to help eliminate problems that might possibly be related to drive systems.
Please fill it in carefully and send it, together with the parameter file with which the error occurred, to Bosch Rexroth.
System description:
Firmware Drive system
Firmware version: Power section:
FWA- - - V -MS Type code: - - - -
Software: Serial number: SN
DriveTop version: SWA-DTOP**-INB- V -MS Hardware index:
Operating system:
Service pack: Control section (only for IndraDrive):
Language:
Type code: - - - - - - -
PC designation:
Serial number: SN
Hardware configuration (system RAM, hard
disk memory,...): Hardware index:
Supply module:
Type code: - - - -
Serial number:
Fault description (detailed description of situation before, during and after fault occurred):
To quickly resolve your problem we ask you to send us also the parameter set with which the error occurred.
Name of parameter set file:
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Handling, Diagnostic and Service Functions 10-15
General conditions:
Mode at time fault occurred: Parameterization mode Operating mode Switch phase
Operating mode active at time fault occurred: , Encoder ,
7-segment display... ...before fault occurred: ...after fault occurred:
Fault status Causes Other defects
occurs permanently unknown problems in the mechanical system
occurs during commissioning incorrect connection power section failure
occurs sporadically external cause control system failure
occurs after approx. hours mechanical damage motor failure
occurs with shocks loose cable connection cable break
depends on temperature moisture in unit defective blower
foreign body in unit defective feedback
Wiring / mechanical setup (e. g. length of cables, grounding, assembly,...):
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
10-16 Handling, Diagnostic and Service Functions Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Notes for Machine Operators 11-1
Replacing Defective Drive If a defective components has to be replaced, the following aspects have
Components to be observed:
Only Rexroth service engineers or especially trained users are allowed to
replace the control section. The replacement of the entire drive
controller is described in the Project Planning Manual for the power
section.
Only Rexroth service engineers are allowed to replace optional modules
of the control section.
The replacement of the supply unit is described in the Project Planning
Manual for the supply unit.
In case devices fail within the warranty period, the defective components
have to be returned to Bosch Rexroth; for addresses and telephone
numbers please see the printed documentation (chapter "Service &
Support") or the Internet (http://www.boschrexroth.com).
Testing and Repairs If tests or repairs are required, the following applies:
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
11-2 Notes for Machine Operators Rexroth IndraDrive
Tests and repairs may only be carried out by the Rexroth service
department or by especially trained staff.
For tests at the installation the corresponding safety regulations have to
be complied with.
Repair of drive components at the machine can be very time-consuming.
For this reason, replace defective drive components completely.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Notes for Installation Programmers 12-1
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
12-2 Notes for Installation Programmers Rexroth IndraDrive
program sequence
start command
No
query command
change bit=1
Yes
No
complete command
continue in program
DF000129v01_en.wmf
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Notes for Installation Programmers 12-3
Note: Before a drive error is cleared, the cause for the occurrence of
the error should be investigated and permanently removed.
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
12-4 Notes for Installation Programmers Rexroth IndraDrive
program sequence
query collective No
error bit=1 from master
communication
status word
Yes
clear error
continue in program
DF000130v01_en.wmf
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Notes for Installation Programmers 12-5
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
12-6 Notes for Installation Programmers Rexroth IndraDrive
program sequence
query collective
No
error bit=1 from
master communication
status word
Yes
continue in program
DF000131v01_en.wmf
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Index 13-1
13 Index
+
+24Volt DC error 7-16
A
Ab 5-1
Abrasion of brake only possible with drive enable 9-120
Absolute encoder offset cannot be saved 9-69
Absolute evaluation of measuring system impossible 9-68
AC 5-1
Acceleration threshold exceeded 7-33
Acquisition velocity not allowed 9-116
Act. modulo value cycle greater than max. travel range 9-59, 9-111
Activation time of enabling control exceeded 7-68
Actual pos. value 1 outside absolute encoder window 7-104
Actual pos. value 2 outside absolute encoder window 7-105
Actual pos. value 3 outside absolute encoder window 7-106
AE 5-1
AF 5-1
AH 5-1
An invalid index was set 9-80
Analog input adjust command 9-12
Appropriate use
Introduction 2-1
Appropriate uses
Uses 2-2
AS 5-1
ASP 5-1
AU 5-1
Autom. commutation
max. motion range 7-8
max. motion range when moving back 7-6
Automatic adjust failed 9-107
Automatic baud rate detection for SERCOS interface 6-5
Automatic commutation
current too low 7-9, 9-88
iteration without result 7-12, 9-90
overcurrent 7-10, 9-89
timeout 7-11, 9-89
Automatic controller setting failed 9-95
Automatic drive check and adjustment 6-37
B
Backup working memory procedure command 9-10
bb 5-1
BOOT 1.1 4-1
Both travel range limit switches activated 7-46, 8-7
Brake check command 9-10
Brake check function not possible 9-59
Brake check only possible with drive enable 9-98
Brake torque too low 8-35, 9-99
Braking resistor overload 7-123
Braking resistor overload prewarning 8-45
Bus failure 7-54
C
Cable
replacing 10-13
Cam shaft invalid 7-75
Cam shaft, encoder 1, real master axis 6-23
Cam shaft, encoder 1, virtual master axis 6-22
Cam shaft, encoder 2, real master axis 6-23
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
13-2 Index Rexroth IndraDrive
D
Default parameters invalid 9-75
Default parameters not available 9-74
Determining travel range only via travel distance 9-97
Device overload prewarning 8-33
Device overload, current limit active 8-11
Device overtemp. Prewarning 8-25
Device overtemperature 2 prewarning 8-21
Device overtemperature 2 shutdown 7-93
Device overtemperature shutdown 7-83
Device temperature monitor defective 7-85
diagnostic drive messages 1-1
diagnostic message
display 1-3
error number 1-4
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Index 13-3
E
Emergency-Stop 7-56, 8-5
Emergency-Stop activated 7-45
Enc. 1
enc. signals incorr. (can be cleared in ph. 2) 7-13
Encoder 1
encoder signals disturbed 8-36
Encoder 2
encoder signals disturbed 8-37
encoder signals incorrect 7-94
End C29 4-3
Error at init. of synchr. motor with reluctance torque 9-41
Error balancing monitor/ground fault 7-126
error classes 1-16
Error clearing only in parameter mode 9-70
Error during abrasion of brake 9-120
Error during initialization 9-82
Error during initialization of control section 7-19
Error during initialization of motor data (->S-0-0021) 9-38
Error during phase progression 7-52
Error during phase regression 7-53
Error during safety related homing procedure 9-121
Error during search for zero pulse 9-82
Error during synchronization to master communication 9-63
Error in control of braking resistor 7-124
Error in non-cyclical data communic. of power section 7-114
Error in offset calculation 9-83
Error in relation TNcyc (S-0-0001) to fine interpol. 9-66
Error internal function call 7-3
Error internal RTOS function call 7-3
Error mechanical link of encoder or motor connection 7-14
error number 1-4
Error of output stage interlock 7-39
Error supply module 7-108
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
13-4 Index Rexroth IndraDrive
F
F2xxx error
commissioning 7-75
F3xxx error
commissioning 7-57
F4xxx error
commissioning 7-49
F6xxx error
commissioning 7-41
F7xxx error
commissioning 7-29
F8xxx errors
commissioning 7-5
F9xxx errors
commissioning 7-1
fatal errors
commissioning 7-5
fatal system errors
commissioning 7-1
fault report 10-6, 10-8
Fault Report 10-14
Feedrate override S-0-0108 = 0 8-29
Field bus
IDN for cycl. actual val. not configurable 9-43
IDN for cycl. command val. not configurable 9-42
length for cycl. actual values exceeded 9-43
max. length for cycl. command val. exceeded 9-42
P-0-4077 missing for cycl. command values 9-44
Tcyc (P-0-4076) incorrect 9-44
firmware download 10-1
Firmware of option 1 of safety technology defective 7-22
Firmware of option 2 of safety technology defective 7-23
Firmware update ? 4-4
Functional package selection changed. Restart 9-49
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Index 13-5
G
generation of diagnostic messages, drive-internal 1-1
H
Hardware trap 7-4
HMV
Braking resistor overload 7-123
HMV
+/-15Volt DC error 7-16
+24Volt DC error 7-16
Braking resistor overload prewarning 8-45
Communication phase 0 6-1
Communication phase 1 6-2
Communication phase 2 6-3
Communication phase 3 6-4
Communication phase 3 transition check 9-1
Communication phase 4 transition check 9-1
Connection error mains choke 7-27
Contactor control error 7-126
Control and power sections ready for operation 6-6
Current measurement trim wrong 7-107
DC bus charging active 6-35
DC bus quick discharge active 6-36
DC bus timeout 8-39
Device overload prewarning 8-33
Device overload shutdown 7-15
Device overload, current limit active 8-11
Device overtemp. Prewarning 8-25
Device overtemperature shutdown 7-83
Device temperature monitor defective 7-85
Drive active, switching not allowed 9-69
Drive system not ready for operation 8-41
Error balancing monitor/ground fault 7-126
Error in control of braking resistor 7-124
Error in non-cyclical data communic. of power section 7-114
Error internal function call 7-3
Error supply shutdown 7-127
Ground fault in motor line 7-125
Hardware trap 7-4
Hardware variant not supported 7-128
Incorrect interrupt timing 7-128
Invalid control section data (->S-0-0022) 9-51
Invalid device code 7-127
Invalid parameters (-> S-0-0021) 9-17
Invalid parameters (->S-0-0022) 9-49
Limit error in parameter (-> S-0-0021) 9-18
Load basic parameters command 9-6
Locked with password 9-81
Mains failure 7-122, 8-44
Module group communication error 7-109
Overcurrent in mains-side power section 7-127
Overvoltage in mains 7-120, 8-43
Overvoltage in power section 7-121, 8-1
Parameter calculation error (->S-0-0022) 9-50
Parameter default value incorrect (-> S-0-0021) 9-80
Parameter limit error (->S-0-0022) 9-50
Phase failure 7-122, 8-44
PL Load parameter default values 7-79
PLL is not synchronized 7-119
Ready for power on 6-7
Reset class 1 diagnostics, error reset 9-3
Softstart fault power supply unit 7-121
Supply module in current control 6-34
Supply module in operation 6-34
Supply module in voltage control 6-34
Switching to parameter mode 9-2
Test run active 6-36
Test run for current control 6-35
Test run for voltage control 6-35
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
13-6 Index Rexroth IndraDrive
I
IBF not correct! 4-3
ID9 + Record length - 1 > length MDT (S-0-0010) 9-23
Inappropriate use 2-2
Consequences, Discharge of liability 2-1
Incorr. parameteriz. of motor enc. (mechanical system) 9-28
Incorr. parameteriz. of opt. enc. (mechanical system) 9-31
Incorr. prarmeterization of measuring enc. (hardware) 9-46
Incorrect access to command value memory 7-109
Incorrect backup of safety technology data 7-74
Incorrect direction of motion 7-36
Incorrect I/O length 7-54
Incorrect input for current 9-112
Incorrect input for frequency 9-113
Incorrect input for power 9-115
Incorrect input for power factor 9-114
Incorrect input for speed 9-114
Incorrect input for voltage 9-113
Incorrect measuring encoder configuration 9-48
Incorrect parameterization of motor encoder (hardware) 9-27
Incorrect parameterization of optional enc. (hardware) 9-31
Incr. encoder emulator
hardware fault 7-101
pulse frequency too high 7-100
Incremental enc. emulator resol. cannot be displayed 9-67
Inertia detection failed 9-94
Initialization velocity encoder 1 too high 9-53
Initialization velocity encoder 2 too high 9-55
Initialization velocity measuring encoder too high 9-57
interface error
commissioning 7-49
Interpolation acceleration = 0 8-23
Interpolation velocity = 0 8-22
Invalid communication phase shutdown 7-52
Invalid control section data (->S-0-0021) 9-39
Invalid control section data (->S-0-0022) 9-51
Invalid control section/firmware combination 7-21
Invalid motor data in encoder memory (->S-0-0021) 9-36
Invalid parameters (-> S-0-0021) 9-17
Invalid parameters (->S-0-0022) 9-49
Invalid power section/firmware combination 7-20
Invalid settings for controller cycle times 9-35
It was impossible to address EnDat memory 7-112
It was impossible to address I2C memory 7-111
It was impossible to address MMC 7-110
K
kind of diagnostic message
commands 1-18
error 1-16
states/operating states 1-18
warnings 1-17
kinds of diagnostic messages 1-1
L
language selection 1-4
LB 5-2
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Index 13-7
M
Mains failure 7-122, 8-44
Manually unlocking the safety door 9-16
Max. travel range too large 9-26
Maximum acceleration exceeded 7-92
Maximum braking time exceeded 7-42
Maximum length for AT exceeded 9-21
Maximum length for MDT exceeded 9-20
Maximum travel range cannot be displayed internally 9-34
Measured values at zero point and max. value identical 9-107
Measuring encoder
encoder signals disturbed 8-38
encoder signals incorrect 7-95
Measuring encoder not available 9-118
Measuring encoder unknown 9-47
Measuring system unavailable 9-68
Measuring wheel operation not possible 9-92
messages during the firmware download 10-1
MMC not correct! 4-3
MMC was removed 7-76
Module group communication error 7-109
Modulo limitation error of measuring encoder 7-119
Modulo limitation error of motor encoder 7-118
Modulo limitation error of optional encoder 7-118
Modulo value for measuring encoder cannot be displayed 9-48
Modulo value for motor encoder cannot be displayed 9-28
Modulo value for optional encoder cannot be displayed 9-32
Motor
replacing 10-12
Motor encoder not available 9-117
Motor encoder unknown 9-29
Motor feedback data not valid 9-93
Motor overload, current limit active 8-10
Motor overtemp. prewarning 8-26
Motor overtemperature shutdown 7-84
Motor temperature monitor defective 7-85
Multiple configuration of a parameter (->S-0-0022) 9-58
N
Negative position limit exceeded 8-4
Negative travel limit exceeded 7-44
Negative travel range limit switch activated 7-48, 8-9
No adjustment with asynchronous motor 9-83
No encoder assigned to slot 1 9-65
No encoder selected 9-118
No IDN on MMC ! 4-2
No sequential block in target position preset memory 7-99
non-fatal error
commissioning 7-75
non-fatal safety technology error
commissioning 7-57
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
13-8 Index Rexroth IndraDrive
O
Operating mode configuration (->S-0-0022) not allowed 9-60
operating states 5-1
Optional encoder not available 9-117
Optional encoder unknown 9-33
Oscillations of input signal outside tolerance range 9-106
Overcurrent external braking resistor 7-28
Overcurrent in power section 7-15, 8-2
Overflow of target position preset memory 7-98
Overvoltage in power section 8-1
P
P0 5-2
P1 5-2
P2 5-2
P3 5-2
Parameter calculation error (->S-0-0022) 9-50
Parameter conversion error (->S-0-0021) 9-18
Parameter default value incorrect (-> S-0-0021) 9-76, 9-79
Parameter limit error (->S-0-0022) 9-50
Parameters not copyable 9-75
Phase switching without ready signal 7-53
Phase synchr. lagless, encoder 1, real master axis 6-21
Phase synchr. lagless, encoder 1, virtual master axis 6-20
Phase synchr. lagless, encoder 2, real master axis 6-21
Phase synchr. lagless, encoder 2, virtual master axis 6-20
Phase synchronization, encoder 1, real master axis 6-19
Phase synchronization, encoder 1, virtual master axis 6-18
Phase synchronization, encoder 2, real master axis 6-19
Phase synchronization, encoder 2, virtual master axis 6-18
PL 5-2
PL Load parameter default values 7-79
Plausibility error actual position value 7-38
Plausibility error during commutation fine adjust 7-88
Plausibility error of actual position values 7-60, 8-15
Plausibility error of safety parameters 7-67, 8-16
Plausibility error of safety related operating mode 8-17
Plausibility error of selection 7-67
Plausibility error parameterized - effective threshold 7-37
Plausibility error safety related operating mode 7-39
PLC - Error nr. 1 7-80
PLC - Error nr. 2 7-81
PLC - Error nr. 3 7-81
PLC - Error nr. 4 7-82
PLC - Warning no. 1 8-19
PLC - Warning no. 2 8-19
PLC - Warning no. 3 8-19
PLC - Warning no. 4 8-20
PLC ? 4-2
PLC watchdog 7-55
Pos. window for safety rel. operational stop exceeded 7-35
Position control lagless, encoder 2 6-14
Position control lagless, encoder 2 drive controlled 6-31
Position mode lagless, encoder 1 6-14
Position mode lagless, encoder 1 drive controlled 6-31
Position mode with encoder 1 6-13
Position mode with encoder 1 drive controlled 6-30
Position mode with encoder 2 6-13
Position mode with encoder 2 drive controlled 6-30
Position of data record in MDT (S-0-0009) even 9-22
Position spindle command 9-6
Positioning block mode lagless, encoder 1 6-32
Positioning block mode lagless, encoder 2 6-33
Positioning block mode, encoder 1 6-32
Positioning block mode, encoder 2 6-33
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Index 13-9
R
Ready for power on 6-7
real-time status bits 1-8
Recalculate actual value cycle 9-14
Refer. missing when selecting safety related end pos. 7-58
Reference cam input not assigned 9-74
Reference mark not detected 9-73
Reference missing when selecting safety related pos. 7-59
Relation TNcyc (S-0-0001) to TScyc (S-0-0002) error 9-24
Replacing
cable 10-13
motor 10-12
replacing devices
drive controllers 10-7
fault report 10-6, 10-8
supply units 10-6
Reset class 1 diagnostics, error reset 9-3
RL 5-2
RL The motor type has changed. 7-78
Rotary scaling not allowed 9-40
Run PLC 4-2
S
Safety command for basic initialization incorrect 7-25
Safety command for clearing errors incorrect 7-69
Safety command for load defaults procedure incorrect 9-77
Safety command for system halt incorrect 7-73
Safety command for system init. incorrect 9-64
Safety command for system start incorrect 7-73
Safety Instructions for Electric Drives and Controls 3-1
Safety rel. position limit val., exc. in neg. dir. 7-31
Safety rel. position limit val., exc. in pos. dir. 7-31
Safety related end position exceeded 7-34
Safety related limited increment exceeded 7-30
Safety related maximum velocity exceeded 7-34
Safety related operational stop active 6-10
Safety related standstill active 6-9
Safety technology configuration parameter invalid 7-26
safety technology error
commissioning 7-29
SBB 5-2
SBH 5-2
Selected process block is not programmed. 8-31
Selectively backup working memory procedure command 9-11
SERCOS error codes 7-129
Set coordinate system procedure command 9-15
Setting only possible in ’Ab’ 9-87
Several motor encoders connected 9-37
SH 5-2
Shift coordinate system procedure command 9-15
Softstart fault power supply unit 7-121
Special mode motion active 6-11
Speed loop error 7-17
Spindle positioning requires drive enable 9-81
Start requires drive enable 9-92
Starting lockout active 6-6
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
13-10 Index Rexroth IndraDrive
T
T2 (S-0-089) + length MDT (S-0-010) > TScyc (S-0-002) 9-39
T2 too small 9-25
T3 (S-0-0008) within MDT (S-0-0089 + S-0-0010) 9-26
T4 > TScyc (S-0-0002) - T4min (S-0-0005) 9-25
Target position out of num. range 8-34
Target position out of travel range 8-27
Time for stopping process exceeded 7-40
Time interval of forced dynamization exceeded 8-18
Time slot parameter > Sercos cycle time 9-21
Timeout of safety command for load defaults procedure 9-78
TNcyc (S-0-0001) or TScyc (S-0-0002) error 9-23
Torque limit = 0 8-30
Torque/force actual value limit active 8-6
Torque/force command value limit active 8-13
Trav. range lim. switch not ass. to dig. input 9-61
travel range error
commissioning 7-41
Travel range exceeded 9-97
Travel range invalid 9-96
Type of construction of motor P-0-4014 incorrect 9-37
Type plate list incomplete 9-115
U
Undervoltage in mains 8-42
Undervoltage in power section 8-43
Undervoltage in power section 7-86, 8-20
Update Error ! 4-4
Use See appropriate use and see inappropriate use
V
Velocity command value > limit S-0-0091 8-34
Velocity command value limit active 8-32
Velocity limit S-0-0091 exceeded 7-18
Velocity synchronization, real master axis 6-17
Velocity synchronization, virtual master axis 6-17
Velocity threshold exceeded 7-32
W
warning classes 1-18
Watchdog 7-4
X
XX
CKS 10-2
DL 10-1
E FW 10-3
E LD 10-3
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Index 13-11
E ADR 10-2
E SEC 10-2
E SEQ 10-3
ERASE 10-2
F ACC 10-4
F CKS 10-4
F2100 10-4
F2101 10-4
F8120 10-5
F8122 10-5
F8129 10-5
F8130 10-5
F9002 10-4
PROG 10-2
Z
ZKS 5-3
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
13-12 Index Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Service & Support 14-1
14.1 Helpdesk
Unser Kundendienst-Helpdesk im Hauptwerk Lohr Our service helpdesk at our headquarters in Lohr am
am Main steht Ihnen mit Rat und Tat zur Seite. Main, Germany can assist you in all kinds of inquiries.
Sie erreichen uns Contact us
14.2 Service-Hotline
Außerhalb der Helpdesk-Zeiten ist der Service After helpdesk hours, contact our service
direkt ansprechbar unter department directly at
14.3 Internet
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
14-2 Service & Support Rexroth IndraDrive
Vertriebsgebiet Mitte
Germany Centre SERVICE SERVICE SERVICE
Rexroth Indramat GmbH CALL ENTRY CENTER HOTLINE ERSATZTEILE / SPARES
Bgm.-Dr.-Nebel-Str. 2 / Postf. 1357 MO – FR MO – FR verlängerte Ansprechzeit
97816 Lohr am Main / 97803 Lohr von 07:00 - 18:00 Uhr von 17:00 - 07:00 Uhr - extended office time -
Kompetenz-Zentrum Europa
from 5 pm - 7 am ♦ nur an Werktagen
from 7 am – 6 pm + SA / SO - only on working days -
Tel.: +49 (0)9352 40-0 Tel.: +49 (0)172 660 04 06 ♦ von 07:00 - 18:00 Uhr
Tel. +49 (0) 9352 40 50 60
Fax: +49 (0)9352 40-4885 oder / or - from 7 am - 6 pm -
service.svc@boschrexroth.de Tel.: +49 (0)171 333 88 26 Tel. +49 (0) 9352 40 42 22
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Service & Support 14-3
Sweden - Schweden Switzerland East - Schweiz Ost Switzerland West - Schweiz West
Bosch Rexroth AB Bosch Rexroth Schweiz AG Bosch Rexroth Suisse SA
Electric Drives & Controls Electric Drives & Controls Av. Général Guisan 26
Ekvändan 7 Hemrietstrasse 2 1800 Vevey 1
254 67 Helsingborg 8863 Buttikon
Tel.: +46 (0) 42 38 88 -50 Tel. +41 (0) 55 46 46 111 Tel.: +41 (0)21 632 84 20
Fax: +46 (0) 42 38 88 -74 Fax +41 (0) 55 46 46 222 Fax: +41 (0)21 632 84 21
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
14-4 Service & Support Rexroth IndraDrive
Czech Republic - Tschechien Czech Republic - Tschechien Hungary - Ungarn Poland – Polen
Bosch -Rexroth, spol.s.r.o. DEL a.s. Bosch Rexroth Kft. Bosch Rexroth Sp.zo.o.
Hviezdoslavova 5 Strojírenská 38 Angol utca 34 ul. Staszica 1
627 00 Brno 591 01 Zdar nad Sázavou 1149 Budapest 05-800 Pruszków
Tel.: +420 (0)5 48 126 358 Tel.: +420 566 64 3144 Tel.: +36 (1) 422 3200 Tel.: +48 22 738 18 00
Fax: +420 (0)5 48 126 112 Fax: +420 566 62 1657 Fax: +36 (1) 422 3201 – service: +48 22 738 18 46
Fax: +48 22 758 87 35
– service: +48 22 738 18 42
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive Service & Support 14-5
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
14-6 Service & Support Rexroth IndraDrive
USA East Region – Ost USA Northeast Region – Nordost USA West Region – West
Bosch Rexroth Corporation Bosch Rexroth Corporation Bosch Rexroth Corporation
Electric Drives & Controls Electric Drives & Controls 7901 Stoneridge Drive, Suite 220
Charlotte Regional Sales Office Northeastern Technical Center Pleasant Hill, California 94588
14001 South Lakes Drive 99 Rainbow Road
Charlotte, North Carolina 28273 East Granby, Connecticut 06026
Tel.: +1 704 5 83 97 62 Tel.: +1 860 8 44 83 77 Tel.: +1 925 227 10 84
+1 704 5 83 14 86 Fax: +1 860 8 44 85 95 Fax: +1 925 227 10 81
Canada East - Kanada Ost Canada West - Kanada West Mexico Mexico
Bosch Rexroth Canada Corporation Bosch Rexroth Canada Corporation Bosch Rexroth Mexico S.A. de C.V. Bosch Rexroth S.A. de C.V.
Burlington Division 5345 Goring St. Calle Neptuno 72 Calle Argentina No 3913
3426 Mainway Drive Burnaby, British Columbia Unidad Ind. Vallejo Fracc. las Torres
Burlington, Ontario Canada V7J 1R1 07700 Mexico, D.F. 64930 Monterrey, N.L.
Canada L7M 1A8
Tel.: +1 905 335 5511 Tel. +1 604 205 5777 Tel.: +52 55 57 54 17 11 Tel.: +52 81 83 65 22 53
Fax: +1 905 335 4184 Fax +1 604 205 6944 Fax: +52 55 57 54 50 73 +52 81 83 65 89 11
Hotline: +1 905 335 5511 Hotline: +1 604 205 5777 mariofelipe.hernandez@boschrexroth.com.mx +52 81 83 49 80 91
michael.moro@boschrexroth.ca david.gunby@boschrexroth.ca Fax: +52 81 83 65 52 80
mario.quiroga@boschrexroth.com.mx
Columbia - Kolumbien
Reflutec de Colombia Ltda.
Calle 37 No. 22-31
Santafé de Bogotá, D.C.
Colombia
Tel.: +57 1 368 82 67
+57 1 368 02 59
Fax: +57 1 268 97 37
reflutec@neutel.com.co
reflutec@007mundo.com
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Bosch Rexroth AG
Electric Drives and Controls
P.O. Box 13 57
97803 Lohr, Germany
Bgm.-Dr.-Nebel-Str. 2
97816 Lohr, Germany
Phone +49 93 52-40-50 60
Fax +49 93 52-40-49 4 1
service.svc@boschrexroth.de
www.boschrexroth.com
Printed in Germany
R911297319 DOK-INDRV*-GEN-**VRS**-WA01-EN-P