PDF p92096 en
PDF p92096 en
PDF p92096 en
Technical Remarks
■ Alternative compressed air connection on the back
■ numbers change color in the case of an error
■ Only round plug connectors with locking tube nuts may be used in explosive atmospheres.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 2010-09-07, © Bosch Rexroth AG, subject to change
Bosch Rexroth AG | Pneumatics
Type Oper- Protec- Output signal Compressed air Note Part No.
ating tion connection
pressure against
range overpres-
min./max. sure
[bar]
PE5-PP-DA04 0/6 1x PNP and 1x analog push-in fitting, Ø 4 Fig. 1 R412007982
PE5-PP-DA04 0 / 10 1x PNP and 1x analog push-in fitting, Ø 4 Fig. 1 R412007986
internal thread,
PE5-PP-G014 0/6 1x PNP and 1x analog Fig. 2 R412007983
G 1/4
internal thread,
PE5-PP-G014 0 / 10 1x PNP and 1x analog Fig. 2 R412007987
G 1/4
15 bar
PE5-NP-DA04 0/6 1x NPN and 1x analog push-in fitting, Ø 4 Fig. 1 R412007984
PE5-NP-DA04 0 / 10 1x NPN and 1x analog push-in fitting, Ø 4 Fig. 1 R412007988
internal thread,
PE5-NP-G014 0/6 1x NPN and 1x analog Fig. 2 R412007985
G 1/4
internal thread,
PE5-NP-G014 0 / 10 1x NPN and 1x analog Fig. 2 R412007989
G 1/4
analog output signal: switchable; 4 - 20 mA; 0 - 10 V DC
Fig. 1
00129830
1) Electrical connection
2) G 1/4 port (closed)
3) Mounting clips for holder and hat rail
4) Push-in fitting Ø 4 mm
Compressed air B1 B2 B3 B4 B5 B6 D1 D2 D3 D4 L1 L2
connection
push-in fitting 35 10.2 33 10.2 3 25 M12x1 4 7.5 G 1/4 67.3 50.5
Ø4
Compressed air L3 L4 T1
connection
push-in fitting 3.5 25 9.5
Ø4
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 2010-09-07, © Bosch Rexroth AG, subject to change
Bosch Rexroth AG | Pneumatics
Fig. 2
00129829
1) Electrical connection
2) G 1/4 port (closed)
3) Mounting clips for holder and hat rail
4) Port G 1/4
Compressed air B1 B2 B3 B4 B5 B6 D1 D2 D4 L1 L2 L4
connection
internal thread 35 10.2 33 10.2 3 25 M12x1 G 1/4 G 1/4 63.8 50.5 25
G 1/4
Compressed air T1 T2
connection
internal thread 9.5 9.5
G 1/4
00130369 00130370
1) Holder
2) Hat rail
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 2010-09-07, © Bosch Rexroth AG, subject to change
Bosch Rexroth AG | Pneumatics
Compressed air B7 H H1 L2 L5
connection
push-in fitting 30 9.2 7,5/15 50.5 35
Ø4
internal thread 30 9.2 7,5/15 50.5 35
G 1/4
00129833
00129831
Block diagram, 1x PNP and 1x analog Block diagram, 1x NPN and 1x analog
1 +24 V
2 Out2, analog
4 Out1
R L2 R L1
3 0V
5
NC
00129834
00129836
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 2010-09-07, © Bosch Rexroth AG, subject to change
Bosch Rexroth AG | Pneumatics
Hysteresis function: switching and resetting behavior dependent on pressure p and time t
[+ p]
[– p]
SP
rP
[t]
Out ( NO )
Out ( NC ) [t]
[t]
00129816
H: Hysteresis
SP = switching point
RP = resetting point
Out (NC): Switch output, break contact
Out (NO): Switch output, make contact
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 2010-09-07, © Bosch Rexroth AG, subject to change
Bosch Rexroth AG | Pneumatics
Delayed hysteresis function: switching and resetting behavior depending on pressure p and time t
[+ p]
[– p] 1 2 3
SP
rP
[t]
Out ( NO )
dS dS dr
1
Out ( NC ) [t]
[t]
00129814
H: Hysteresis
SP = switching point
RP = resetting point
Out (NC): switch output, break contact
Out (NO): switch output, make contact
dS: switching delay
dR = reset delay
1) period of pressure over the switching point < dS: pressure sensor does not switch
2) Period of pressure over the switching point > dS: pressure sensor switches
3) Period of pressure under the resetting point > dR: pressure sensor switches
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 2010-09-07, © Bosch Rexroth AG, subject to change
Bosch Rexroth AG | Pneumatics
Window function: switching and resetting behavior depending on pressure p and time t
[+ p]
[– p]
FH
FL
[t]
Out ( NO )
0
[t]
Out ( NC )
[t]
00129815
F: pressure window
FH: pressure band, upper value
FL: pressure band, lower value
Out (NC): switch output, break contact
Out (NO): switch output, make contact
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 2010-09-07, © Bosch Rexroth AG, subject to change