Gauge Pressure 264GS
Gauge Pressure 264GS
Gauge Pressure 264GS
5–year stability
2600T Pressure Transmitters
Model 264GS,
3000kPa 30kPa 150kPa – –50°C (–58°F); –20°C (–4°F) for Viton gasket.
U 30bar 0 abs 0.3bar 1.5bar
– –15°C (+5°F) for perfluoroelastomer gasket
435psi 4.35psi 21.7psi
10000kPa 100kPa Upper limit
100bar 1bar
R 1450psi 0 abs 14.5psi – Silicone oil, inert fluid and white oil: 121°C (250°F)
60000kPa 600kPa
600bar 6bar Storage
8700psi 87psi Lower limit: –50°C (–58°F); –40°C (–40°F) for LCD indicators
V 0 abs
Upper limit: +85°C (+185°F)
Note : Lower Range Limit (LRL) for 264AS is 0 abs for all ranges
Span limits
Maximum span = URL
IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR
CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS
POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS.
Turn on time
Operation within specification in less than 1s with minimum
damping.
Insulation resistance
> 100MΩ at 1000VDC (terminals to earth)
2
2600T Pressure Transmitters
Model 264GS,
– 0.5MPa, 5bar, 72.5psi for sensor code L Wet and dust-laden atmospheres
– 6MPa, 60bar, 870psi for sensor code U The transmitter is dust and sand tight and protected against immersion
effects as defined by EN60529 (1989) to IP 67 (IP 68 on request) or by
– 20MPa, 200bar, 2900psi for sensor code R NEMA to 4X or by JIS to C0920. IP65 with Harting Han connector.
– 90MPa, 900bar, 13050psi for sensor code V
Hazardous atmospheres
– 0.6MPa, 6bar, 87psi for perfluoroelastomer gasket
With or without output meter/integral display
Proof pressure – COMBINED ATEX (Intrinsic safety and flameproof), FM and CSA
ZELM approval. See below detailed classifications.
The transmitter can be exposed without leaking to line pressure of up to – COMBINED INTRINSIC SAFETY and FLAMEPROOF/EUROPE:
– 1MPa, 10bar, 145psi for sensor codes C, F ATEX/ZELM approval
II 1 GD T50°C, EEx ia IIC T6 (–40°C δ Ta δ+40°Χ)
– 0.5MPa, 5bar, 72.5psi for sensor code L T95°C, EEx ia IIC T4 (–40°C δ Ta δ+85°Χ)
II 1/2 GD T85°C, EEx d IIC T6 (–40°C δ Ta δ +75°C)
– 6MPa, 60bar, 870psi for sensor code U
– INTRINSIC SAFETY/EUROPE:
– 20MPa, 200bar, 2900psi for sensor code R ATEX/ZELM approval
II 1 GD T50°C, EEx ia IIC T6 (–40°C δ Ta δ+40°Χ)
– 90MPa, 900bar, 13050psi for sensor code V T95°C, EEx ia IIC T4 (–40°C δ Ta δ+85°Χ)
– 0.6MPa, 6bar, 87psi for perfluoroelastomer gasket – TYPE "N"/EUROPE:
ATEX/ZELM type examination (for HART)
II 3 GD T50°C, EEx nL IIC T6 (–40°C δ Ta δ+40°Χ)
Environmental limits
T95°C, EEx nL IIC T4 (–40°C δ Ta δ+85°Χ)
Electromagnetic compatibility (EMC) – FLAMEPROOF/EUROPE:
ATEX/CESI approval
Comply with EN 61000–6–3 for emission and EN 61000–6–2 for II 1/2 GD T85°C, EEx d IIC T6 (–40°C δ Ta δ +75°C)
immunity requirements and test; – CANADIAN STANDARDS ASSOCIATION and FACTORY MUTUAL:
– Explosionproof: Class I, Div. 1, Groups A, B, C, D
Radiated electromagnetic immunity level: 30V/m – Dust ignitionproof : Class II, Div. 1, Groups E, F, G
(according to IEC 1000–4–3, EN61000–4–3) – Suitable for : Class II, Div. 2, Groups F, G; Class III, Div. 1, 2
Conducted electromagnetic immunity level : 30V – Nonincendive: Class I, Div. 2, Groups A, B, C, D
(according to IEC 1000–4-6, EN 61000–4–6) – Intrinsically safe: Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G
AEx ia IIC T6/T4, Zone 0 (FM)
Surge immunity level (with surge protector): 4kV – STANDARDS AUSTRALIA (SAA): TS Approval
(according to IEC 1000-4–5 EN 61000–4–5) - Intrinsically safe Ex ia IIC T4/T5 (–20°C δ Ta δ+80°Χ) only HART
- No sparking Ex n IIC T4/T6 (–20°C δ Ta δ+80°Χ) only HART
Fast transient (Burst) immunity level: 4kV - Flameproof Ex d IIC T4/T6 (–20°C δ Ta δ+80°Χ)
(according to IEC 1000–4–4 EN 61000–4–4) - Dust ignitionproof DIP A21 Ta T6 (–20°C δ Ta δ+80°Χ)
– INTRINSIC SAFETY/CHINA
Pressure equipment directive (PED) NEPSI approvalEx ia IIC T4-T6
Comply with 97/23/EEC Category III Module H. – FLAMEPROOF/CHINA
NEPSI approvalEx d IIC T6
– GOST (Russia), GOST (Kazakhstan), Inmetro (Brazil)
Humidity
based on ATEX
Relative humidity: up to 100% annual average
Condensing, icing: admissible
Vibration resistance
Accelerations up to 2g at frequency up to 1000Hz
(according to IEC 60068–2–6)
3
2600T Pressure Transmitters
Model 264GS,
For EEx ia and other intrinsically safe approval power supply must Two–wire 4 to 20mA, user-selectable for linear or 5th order or two 2nd
not exceed 30VDC. order switching point selectable programmable polynomial output.
(volts)
10.5 10.7 12.3 12.5 13.3 15.3
Load limitations
4 to 20mA and HART total loop resistance :
Supply voltage – min. operating voltage (VDC)
R(kΩ) = –––––––––––––––––––––––––––––––––––––––
22.5
A minimum of 250Ω is required for HART communication.
Optional indicators
Output meter
CoMeter and Prometer LCD :
5-digit (±99999 counts) programmable with 7.6mm. high (3in),
7-segment numeric characters plus sign and digital point for digital
indication of output value in percentage, current or engineer unit;
Integral display
LCD, 15 lines x 56 column dot matrix providing 2 lines indication as
– top: 5-digit (numeric) plus sign or 7-digit alphanumeric
– bottom: 7-digit alphanumeric
and additional 50-segment bargraph for indication of analog output
in percentage.
4
2600T Pressure Transmitters
Model 264GS,
Integral display
LCD, 15 lines x 56 column dot matrix providing 2 lines indication as Additional blocks
– top: 5-digit (numeric) plus sign or 7-digit alphanumeric 1 enhanced Resource block
and additional 50-segment bargraph for indication of output in 1 custom Advanced Diagnostics transducer block including Plugged
percentage of the analog input function block assigned to the primary Input Line Detection
variable.
1 custom Local Display transducer block
User-definable matrix display mode:
Number of link objects
– process variable in pressure units or 35
5
2600T Pressure Transmitters
Model 264GS,
Dynamic performance (according to IEC 61298–1 definition) Optional CoMeter and ProMeter ambient temperature
Dead time: 40ms Total reading error per 20K (36°F) change between the ambient limits
of –20 and +70°C (-4 and +158°F) :
Time constant (63.2% of total step change):
±0.15% of max span (16mA).
– 150 ms for all sensors
Response time (total) = dead time + time constant. Supply voltage
Within voltage/load specified limits the total effect is less than
Accuracy rating 0.005% of URL per volt.
% of calibrated span, including combined effects of terminal based
linearity, hysteresis and repeatability. Load
Within load/voltage specified limits the total effect is negligible.
For fieldbus versions SPAN refer to analog input function block outscale
range
Electromagnetic field
Model 264GS Total effect : less than 0.10% of span from 20 to 1000MHz and for
– ±0.075% for TD from 1:1 to 15:1 (10:1 for sensor C) field strengths up to 30V/m when tested with shielded conduit and
grounding, with or without meter.
6
2600T Pressure Transmitters
Model 264GS,
Sensor fill fluid Cleaning procedure for oxygen service (not for sensor V)
Silicone oil; inert fill (Carbon fluoride); white oil (FDA).
Test Certificates (test, design, calibration, material traceability)
Mounting bracket (**)
Tag and manual language
Zinc plated carbon steel with chrome passivation;
Communication connectors
AISI 316 L ss.
Process connections
Sensor housing
1
/2 – 14 NPT female or male; DIN EN837–1 G 1/2 B.
AISI 316 L ss.
Packing
Carton 26 x 26 x 18cm approx (10 x 10 x 7in).
(**) U-bolt material: AISI 400 ss; screws material: high-strength alloy steel or
AISI 316 ss.
7
2600T Pressure Transmitters
Model 264GS,
8
2600T Pressure Transmitters
Model 264GS,
L ES N
100 (3.94) C IO
Electronic Covers locking
CI R I R
CU
NS
!
side Terminal screw AN
ET QU GARD
ERKE L
E'T H E N
CER LE BIEN FUVECO VER TI GH
side W
RME P COTE
Integral display
housing
Output meter
housing
50 (1.97)
CH27
56 (2.20)
70 (2.75)
135 (5.31)
1
/2 – 14 NPT female connection
!
side screw AN
ET QU GARD
ERKE L
E'T H E N
Integral display W CER LE BIEN FUVECO VER TI GH
RME P COTE
housing
Output meter
housing
58 (2.28)
56 (2.20) CH22
G 1/2 B
135 (5.31)
9
2600T Pressure Transmitters
Model 264GS, 264AS SS/264GS/AS_6
Integral display
housing
Output meter
housing
55 (2.17)
56 (2.20) CH22
135 (5.31)
1
/2 – 14 NPT male connection
10
2600T Pressure Transmitters
Model 264GS,
Electrical connections
HART Version
Internal ground
termination point
Remote
indicator
-
6 7 8
5 9
4
23 40 60 10
M+
0 20 80
% 10
0
0
Kent-Taylor
-
Line load M
+
250 ohm min
+
+
Power GND
TEST COMM
source
External ground
- - 691HT
termination point
F1 F2 F3 F4
6 5 4
PV
SERIALLINK
1
-
REVIEW CONF
Optional 7
- +
TRIM
1 2 3
8 2 3
JKL
4
MNO
5
PQ R
6
Test points
Receiver ST U
7
VWX
8
YZ#
HART hand-held communicator may be connected at any wiring termination point in the loop, providing the minimum resistance
is 250 ohm. If this is less than 250 ohm, additional resistance should be added to allow communications
FIELDBUS Versions
2 4
M12 x 1 connector
Fieldbus line
2
(polarity independent)
3 1 BUS CONNECTIONS
External ground
termination point
PIN (male) IDENTIFICATION
FOUNDATION PROFIBUS
FieldbusPA
1FF-PA+
2FF+GROUND
3SHIELDPA–
4GROUNDSHIELD
11
2600T Pressure Transmitters
Model 264GS,
1
AISI 316 L ss /2 – 14 NPT female NACE B
AISI 316 L ss / – 14 NPT male
1 2 NACE T
AISI 316 L ss DIN EN837– 1 G 1/2 B NACE P
Hastelloy C276™ 1/2 – 14 NPT female NACE E
Hastelloy C276™ 1/2 – 14 NPT male NACE K
Hastelloy C276™ DIN EN837– 1 G 1/2 B NACE D
Gasket – 9th character
1
Aluminium alloy (Barrel version) /2 – 14 NPT A
Aluminium alloy (Barrel version) M20 x 1.5 (CM 20) B
Aluminium alloy (Barrel version) Pg 13.5 D
Aluminium alloy (Barrel version) 1/2 GK C
Aluminium alloy (Barrel version) Harting Han connector E
Aluminium alloy (Barrel version) Fieldbus connector (general purpose only) (Note 4) G
Aluminium alloy copper-free (Barrel version) 1/2 – 14 NPT (general purpose only) (Note 4) H
Aluminium alloy copper-free (Barrel version) M20 x 1.5 (CM 20) L
Aluminium alloy copper-free (Barrel version) Pg 13.5 N
Aluminium alloy copper-free (Barrel version) 1/2 GK M
Aluminium alloy copper-free (Barrel version) Harting Han connector P
Aluminium alloy copper-free (Barrel version) Fieldbus connector R
AISI 316 L ss (Barrel version) 1/2 – 14 NPT (general purpose only) (Note 4) S
AISI 316 L ss (Barrel version) M20 x 1.5 (CM20) (general purpose only) (Note 4) T
AISI 316 L ss (Barrel version) Pg 13.5 V
AISI 316 L ss (Barrel version) 1/2 GK U
AISI 316 L ss (Barrel version) Fieldbus connector Z
12
2600T Pressure Transmitters
Model 264GS,
XX XX XX XX XX XX XX XX XX XX XX XX XX
Electrical certification
ATEX Group II Category 1 GD – Intrinsic Safety EEx ia E1
ATEX Group II Category 1/2 GD – Flameproof EEx d (Note 2) E2
ATEX Group II Category 3 GD – Type of protection "N" EEx nL design compliance (Note 7) E3
Canadian Standard Association (CSA) (only 1/2– 14NPT, M20 and Pg 13.5 electrical connection) - (Note 8) E4
Standards Australia SAA (Not Ex d; Not Ex ia and Ex n for PROFIBUS PA and FOUNDATION Fieldbus) E5
Factory Mutual (FM) approval (only with 1/2– 14NPT, M20 and Pg 13.5 electrical connection) - (Note 8) E6
Combined ATEX - Intrinsic Safety and Flameproof (Note 2) E7
Combined ATEX, FM and CSA (only with 1/2– 14NPT, M20 and Pg 13.5 electrical connection) (Notes 7,8) EN
NEPSI (China) - Intrinsic Safety Ex ia EY
NEPSI (China) - Flameproof Ex d (Note 2) EZ
GOST (Russia) EEx ia W1
GOST (Russia) EEx d (Note 2) W2
GOST (Kazakhstan) EEx ia W3
GOST (Kazakhstan) EEx d (Note 2) W4
Inmetro (Brazil) EEx ia W5
Inmetro (Brazil) EEx d (Note 2) W6
Inmetro (Brazil) EEx nL W7
Metrologic (Russia) WC
Metrologic (Kazakhstan) WD
Output meter
Integral LCD
Digital LCD integral display L1
Operating manual
German M1
Italian M2
Spanish M3
French M4
Configuration
Standard – Pressure = inH2O/psi at 20° C; Temperature = deg. F N2
Standard – Pressure = inH2O/psi at 4° C; Temperature = deg. F N3
Standard – Pressure = inH2O/psi at 20° C; Temperature = deg.C N4
Standard – Pressure = inH2O/psi at 4° C; Temperature = deg. C N5
Custom N6
Preparation procedure
Oxygen service cleaning (only available with inert fill and Viton gasket) – Pmax =21MPa/210bar/3045psi; Tmax = 60° C/140° F P1
Certificates
Inspection certificate EN 10204– 3.1 of calibration (9-point) C1
Certificate of compliance with the order EN 10204– 2.1 of instrument design C6
Material traceability
Certificate of compliance with the order EN 10204– 2.1 of process wetted parts H1
Inspection certificate EN 10204– 3.1 of process wetted parts H3
Connector
Fieldbus 7/8 (Recommended for FOUNDATION Fieldbus) - (supplied loose without mating female plug) (Notes 6, 9) U1
Fieldbus M12x1 (Recommended for PROFIBUS PA) - (supplied loose without mating female plug) (Notes 6, 9) U2
Harting Han – straight entry (Notes 5, 9) U3
Harting Han – angle entry (Notes 5, 9) U4
13
2600T Pressure Transmitters
Model 264GS,
THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'S
RESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING.
14