3c841 Bumi Unit 1
3c841 Bumi Unit 1
3c841 Bumi Unit 1
BUMI ARMADA
Unit Number 1
Solar Turbines
A Caterpillar Company
Solar Turbines
A Caterpillar Company
FOREWORD
This technical manual contains manufacturing records and quality/test documentation for Gas Turbine Driven equipment
designed and manufactured by Solar Turbines Incorporated in San Diego, California.
The technical manual is provided in volume sets. The manual contains the approved Inspection and Test Plan, Package
Certificate of Conformance, required records, reports, data sheets and inspection and test reports. Each volume is complete
and described below.
BUMI ARMADA
Unit Number 1
Solar Turbines
A Caterpillar Company
Proprietary Notice
The contents of this technical data book are proprietary data of Solar Turbines Incorporated, a subsidiary
of Caterpillar Inc. Reproduction or use of any part for other than the operation and maintenance of Solar
equipment is permissible only if expressly authorized in writing by Solar. This software and accompanying
documentation are distributed only in accordance with and subject to the terms of the Solar Turbines
Incorporated Standard Terms and Conditions for the licenses of the software (the "Solar License"). The
software and accompanying documentation are copyrighted property of Solar Turbines Incorporated and
all rights are reserved. You may not copy, modify, transfer, sublicense, rent, lease, convey, translate,
convert to any programming language or format or decompile or disassemble the software or any copy,
modification or merged portion, in whole or part, except as expressly provided in the Solar License. A
violation of the Solar License will be prosecuted to the full extent of all applicable law, including, but not
limited to, United States Copyright, patent and trademark laws and regulations. Solar, Saturn, Centaur,
Mars, Mercury, Taurus, Titan, SoLoNOx, and Turbotronic are trademarks of Solar Turbines Incorporated.
Cat and Caterpillar are trademarks of Caterpillar Inc. Specifications are subject to change without notice.
Solar Turbines
A Caterpillar Company
The Table of Contents items for this project correspond to the ITP item numbers identified within each section of the
ITP (Inspection and Test Plan). These items are identified with an "X" in column A of the project ITP. A copy of the
Project ITP is supplied in the last section for reference.
BUMI, PD # 3C841
Table of Contents
ITEM
NUMBER
01.08 GENERATOR
1. Factory Acceptance Test
01.08 GENERATOR
2. Electrical Device List
01.08 GENERATOR
3. Electrical Device Certificates
01.08 GENERATOR
4. Abs Certificate
BUMI, PD # 3C841
Table of Contents, Continued
ITEM
NUMBER
01.11 COUPLING
Balance Data Report
ITEM
NUMBER
ITEM
NUMBER
ITEM
NUMBER
NOTES:
1 – Hayden Part Number :041551
S:\QA Data Books\#1 BOOKS OPEN TO WORK\3C841 BUMI\SECTIONS 00 - 10\Section 01 NEED\Hayden\Electrical Device 40670AKM.doc
Page 1
SECTION: 01.06
4. ABS CERTIFICATE
SECTION: 01.07
As Required by the Provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VIII, Division 1
1. Manufactured and certified by Filter Specialists, Inc., 2302 S. North Rd., Grand Island, Nebraska, 68803, USA
(Name and address of manufacturer)
2. Manufactured for Hydac, USA
(Name and address of purchaser)
3. Location of Installation Hydac Technology Corp., 2260 City Line Rd., Bethlehem, Pennsylvania, 18017, USA
(Name and address)
5. The chemical and physical properties of all parts meet the requirements of material specifications of the ASME BOILER AND PRESSURE VESSEL
CODE. The design, construction, and workmanship conform to ASME Rules, Section VIII, Division 1 2007 to 2007
N/A N/A (year) [Addenda (Date)]
(Code Case numbers) (Special Service per UG-120(d))
Min. design metal temp. -20 °F at 150 psi . Hydro, pneu., or comb. test pressure 195 psi
10. Nozzles, inspection and safety valve openings:
We certify that the statements made in this report are correct and that all details of design, material, construction, and workmanship of this vessel conform to the ASME BOILER
CERTIFICATE OF SHOP/FIELD COMPLIANCE
AND PRESSURE VESSEL CODE, Section VIII, Division 1. "U" Certificate of Authorization No. 19403 expires 08/26/2008
Date 02/28/2008 Co. name Filter Specialists, Inc. Signed
(Manufacturer) (Representative)
Vessel constructed by Filter Specialists, Inc. at 2302 S. North Rd., Grand Island, Nebraska, 68803, USA I, the
undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province NE
of employed by HSB CT of Lisle, IL
and have inspected the component described in this Manufacturer's Data Report on
February 28, 2008 and state that, to the best of my knowledge and belief, the Manufacturer has constructed this pressure vessel in accordance with ASME BOILER AND
PRESSURE VESSEL CODE, Section VIII, Division 1. By signing this certificate neither the Inspector nor his/her employer makes any warranty, expressed or implied, concerning
the pressure vessel described in this Manufacturer's Data Report. Furthermore, neither the Inspector nor his/her employer shall be liable in any manner for any personal injury or
property damage or a loss of any kind arising from or connected with this inspection.
GENERATOR
GENERATOR
GENERATOR
GENERATOR
4. ABS CERTIFICATE
SECTION: 01.11
COUPLING
2. ABS CERTIFICATE
SECTION: 01.13
2. ABS CERTIFICATE
SECTION: 02.01
PQR, WPS
SECTION: 02.02
WQR
SECTION: 02.03
SKID FABRICATION
TRAVELER
SECTION: 02.04
TRAVELER
SEE TRAVELER IN ITEM 02.03
SECTION: 02.05
TRAVELER
SEE TRAVELER IN ITEM 02.03
SECTION: 03.05
MANIFOLD RADIOGRAPHY
1. X-RAY REPORT
SECTION: 03.06
5 Console Wiring and This test is to insure that the console legal packet is complete,
Shortages and that the console components and wiring are in
accordance with the legal wiring diagram and Layout.
7 Switch and Jumper Verify that the switches and jumpers are set in accordance
Settings with the electrical schematic.
8 Horn/Hour Meter/Start To disable the alarm horn, hour meter, and start counter
Counter Disconnect during test.
10 Connect External DC To verify that the grounds are isolated from each other, there
Power are no "short" circuits and that each circuit breaker powers its
circuit/bus only per the electrical print.
12 Load Controller Software Connect the programming terminal (PC) to the controller and
load the project application software.
19 Load Display Program Load the display software into the control console display
(TT4000) terminal/computer.
21 PLC LED's All Green Verify no communication error exists between the Controller
and the display.
23 I/O Overview Configuration Verify that the I/O configuration is complete and correctly set
Verification up using the electrical schematic – vs. – the Controller.
25 Preliminary for I/O To create a reduced copy of the electrical schematic, and
hardware Checks provide information on how to perform a cross reference.
25A Discrete Inputs To verify that all Discrete Input I/O channels are functioning
properly in accordance with the legal electrical schematic
diagram.
25B Discrete Outputs To verify that all Discrete Output I/O channels are functioning
properly in accordance with the legal electrical schematic
diagram.
25C Frequency Inputs To verify that all Frequency Input I/O channels are functioning
properly in accordance with the legal electrical schematic
diagram.
25D Thermocouple / Milli-volt To verify that all Thermocouple / Milli-volt Input I/O channels
Inputs are functioning properly in accordance with the legal electrical
schematic diagram.
25E Analog Inputs To verify that all Analog Input I/O channels are functioning
properly in accordance with the legal electrical schematic
diagram.
25F Analog Outputs To verify that all Analog Output I/O channels are functioning
properly in accordance with the legal electrical schematic
diagram.
25H RTD Inputs To verify that all RTD Input I/O channels are functioning
properly in accordance with the legal electrical schematic
diagram.
27 Vibration Setup To verify the vibration system wiring from the vibration
modules to the end of the line.
28 Vibration Channel Fault To verify module fault alarm annunciation associated with the
Monitor Vibration Monitor.
Solar Turbines
A Caterpillar Company CONTROL CONSOLE Customer Witness 11/14/2008
30 Vibration - Accelerometer To verify the accuracy of the input for accelerometer vibration
channels.
31 Vibration - Displacement To verify the accuracy of the input for displacement vibration
channels.
32 Vibration - Thrust / Axial To verify the accuracy of the input for displacement vibration
channels.
49 Lamp Test To verify the lamps on the turbine control panel are
operational.
69 Controller Powerup To verify that the I/O modules communicate properly and a
fast stop shutdown occurs on initial Controller power up.
91 Relay Backup - Fire Signal Verify that in the event of a fire and a Controller failure, the
Control backup system activates the pre/post lube oil pump while the
roll down timer is timing.
92 Backup System Lube Verify that in the event of a Controller failure, the backup
Pump Control system will control the lube oil pumps for the duration of the
total post lube timer.
93 Watchdog Timer Verify that in the watchdog timer causes a backup system
active in case of Controller failure.
Solar Turbines
A Caterpillar Company CONTROL CONSOLE Customer Witness 11/14/2008
201 A/C Visual Inspection To verify the correct selection of the A/C meters and their
proper wiring.
202 A/C Simulator Hookup To provide a consistent and logical method for connecting the
A/C simulator.
203 CGCM Module Verification To verify that the CGCM is installed and functions properly.
204 A/C Metering Accuracy To verify the accuracy of the AC meters and the CRT
displayed AC parameters.
206 A/C Generator Control To verify statically the circuitry and operation of the CGCM
voltage regulator.
208 A/C Single Unit Auto Sync To verify the unit will automatically synchronize with a live Bus.
(Hot Bus)
209 A/C Single Unit Auto Sync The purpose of this operation is to verify statically that the
(Dead Bus) control console is tuned to automatically synchronize to a
dead bus.
157 Serial Number Record To record the serial numbers of specified components.
Solar Turbines
A Caterpillar Company CONTROL CONSOLE Customer Witness 11/14/2008
158 Set Console Timers To verify that all electrical timers are set per the legal drawing
and torque painted.
159 Post Test Visual The purpose of this operation is to compare the wiring of the
Inspection controls with the legal electrical drawing, log any
discrepancies discovered, and take the necessary corrective
action.
160 Final I/O Check To verify if new I/O modules or channels were added and
perform a hardware check on them.
161 Clear Open Discrepancies To verify all operations have been performed and the
Automated Test Log (ATL) is reviewed.
162 Legal Drawings Clear To verify all changes shown on the legal electrical drawing
have been performed and all pencil markings have been
removed.
164 Test Complete and To obtain authorization from test engineer to disconnect the
Authorized for Disconnect turbine controls and verify all test equipment and accessories
are disconnected.
SECTION: 04.03
Project 100 Project Test To perform a number of automated diagnostic checks on the project
software.
TE39
Project 105 Generate Test Reports To create all reports required for testing.
TE39
Project 110 Address Check and Scaling, To ensure addresses in the electrical schematic match those in the
Controller vs. Prints controller; to verify transmitter scaling in electrical schematic and hydro-
TE39
mechanical drawings match that in the controller.
Project 120 I/O Configuration for Sales- To verify the I/O module configuration is complete and correctly set for
Order Modules sales-order added modules.
TE39
Project 130 Sales Order Constants To verify the software constants are set correctly for the sales order
requirements.
TE39
Project 140 Review Project Creation Notes To verify issues listed in the Project Creation Notes have been properly
addressed by the DE.
TE39
Ancillary 020 Turbine Air Inlet Filter To verify the proper monitoring of the turbine air inlet filter transmitter.
Transmitter Monitoring TE39
Ancillary 200 Battery Charger Monitoring To verify the battery charger fail normally closed switch contact is
monitored for fault indication with alarm annunciation. The turbine is
TE39
shut down if the battery charger is faulted over an hour. The control 24
Vdc input is also monitored for low and high voltage conditions.
Ancillary 300 Provides control of on-crank To verify the control of the On-crank water wash valve and the status
water wash system indication that On-crank wash is active.
TE39
Ancillary 310 Provides control of on-line / To verify the control of the On-line water wash valve and the status
running water wash system indication that On-line wash is active.
TE39
Enclosure Enclosure Prestart To verify the prestart enclosure purge logic, where applicable and failure
010 logic for the enclosure fan(s) during this prestart purge will result in a unit
TE39
shutdown.
Enclosure Enclosure Temperature To verify the enclosure temperature measurement device (RTD) input is
020 Monitoring scaled and sent to the HMI. Along with RTD failure check and high
TE39
temperature alarm annunciated when the limits have been exceeded.
Enclosure Enclosure Exhaust Gas Sensor To verify the "Exhaust" combustible gas detection sensor transmitter
030 Monitoring input is scaled and sent to the HMI.
TE39
Enclosure Prestart Enclosure Exhaust Gas To verify enclosure Inlet Gas Detection Prestart Check While the engine
050 Detection is shut down and when the enclosure purge is almost complete, if the
TE39
exhaust gas sensor detects a high gas level, the unit will not be allowed
to start.
Enclosure Enclosure Door Position Switch To verify that the enclosure door position switch input is monitored.
070 Monitoring Alarm annunciated as required.
TE39
Enclosure Enclosure Ventilation To verify the proper function of vent fan actuation when package devices
075 are on or combustible gas is detected inside the enclosure. Fan
TE39
operation is locked out during a fire.
Enclosure Enclosure Vent Fan Operation To verify the logic of enclosure vent fan actuation when package devices
080 are on or combustible gas is detected inside the enclosure and that the
TE39
fan operation is locked out during a fire. To verify the (optional) fan
failure logic.
Enclosure Enclosure Filter DP Switch To verify that the turbine enclosure vent filter DP high switch input is
120 Monitoring monitored and alarm annunciates as required.
TE39
Enclosure Driven Equipment Enclosure To verify that the driven equipment enclosure vent filter DP high switch
130 Filter DP Switch Monitoring input is monitored and alarm annunciates as required
TE39
Enclosure Enclosure Low Pressure To verify that the enclosure low pressure input is monitored and an alarm
140_CF Monitoring and/or shutdown annunciates as required
TE39
Enclosure QP Configuration To verify the proper configuration of the Quantum Premier upon
170 initialization.
TE39
Enclosure Fire System Monitoring - QP To verify that the fire system inputs are examined and alarms and
180 shutdowns annunciates as required. Verifies auto configuration, Runtime
TE39
data storage and clock sync features.
Enclosure QP Clock Synchronization To verify the proper synchronization of the Quantum Premier clock
190 during either configuration or daily at midnight.
TE39
Enclosure QP Runtime Data To verify the correct Quantum Premier System runtime data.
200 TE39
Exhaust 100 Engine Purge To verify that the exhaust purge time and indication of purge duration
complete, along with indication of purge time remaining for display
TE39
purposes.
Fuel 010 Fuel Inputs - Annunciations To verify the proper annunciations of fuel input failures.
TE39
Fuel 016 T1 Temperature Averaging To verify the proper air inlet temperature signal averaging and filtering.
TE39
Fuel 020 Fuel Inputs - Dual Fuel To verify the proper calculation of the percent load on the turbine based
Generator Sets on the measured real power of the generator, measured T1 temperature,
TE39
and the site altitude.
Fuel 025 Fuel Inputs - Thermocouples To verify the proper scaling of and failure annunciations for the
thermocouples.
TE39
Fuel 040_CF Fuel Select To verify the proper auto and manual user selection of fuel type.
TE39
Fuel 050 Fuel Transfer Sequence To verify the sequencing logic for control of fuel valves during transfer.
TE39
Fuel 060 Gas Fuel Valve Check To verify the checks of gas fuel shutoff valves for shutoff integrity during
start and prior to transfer to gas fuel.
TE39
Fuel 065 Gas Fuel Vent To verify the proper performance of the gas fuel vent sequence.
TE39
Fuel 070 Gas Fuel Valve Control To verify the light off, start, and run sequence for gas fuel.
TE39
Fuel 090 Gas Fuel Pressure To verify the monitoring of gas fuel pressure.
TE39
Fuel 110 Liquid Fuel Purge To verify the control and sequence of the liquid fuel system during start,
purge crank, shutdown , and/or transfer.
TE39
Fuel 116 Liquid Fuel Filter Off-Skid To verify the proper monitoring of the off-skid liquid fuel filter transmitter
DP.
TE39
Fuel 118 Liquid fuel Coalescer Off-Skid To verify the proper monitoring of the off-skid liquid fuel coalescer
transmitter DP and level switch.
TE39
Fuel 120 Liquid Fuel Valve Control To verify the light off, start, and run sequence for liquid fuel.
TE39
Fuel 123 Liquid Manifold PCD Purge To verify the Liquid fuel manifold forward purge for dual fuel
configurations with two forward purge valves.
TE39
Fuel 124 Liquid Divider Block To verify the proper Monitoring of the liquid fuel injectors for posibble
clogging.
TE39
Fuel 150 Liquid Fuel Pressure To verify the monitoring of liquid fuel pressure.
TE39
Fuel 160 Corrected Speed To verify the proper calculation of corrected speed.
TE39
Fuel 190 NGP Error for Acceleration To verify the proper NGP error for acceleration from self-sustaining
speed to idle.
TE39
Fuel 195 NGP Average Acceleration Rate To verify the proper NGP average acceleration rate.
TE39
Fuel 197 NGP Acceleration Rate To verify the proper monitoring of the acceleration rate during start.
TE39
Fuel 200 NGP Load Control Error To verify the proper NGP load control error.
TE39
Fuel 205 NGP Max Continuous To verify the proper calculation of the maximum continuous Ngp and time-
delayed Ngp overspeed settings based on engine load.
TE39
Fuel 210 NGP Alarm and Shut Down To verify the proper alarm and shut down annunciation for the gas
producer.
TE39
Fuel 330 T5 Max Reference Temperature To verify the proper calculation of T5 maximum reference temperature.
TE39
Fuel 390 T5 Thermocouple Inputs Checks To verify the proper checks of T5 thermocouples.
TE39
Fuel 410 T5 Temperature Monitoring To verify the monitoring of the engine T5.
TE39
Fuel 450 T5 Max Control To verify the annunciation if maximum temperature exceeds pre-defined
limit above the average.
TE39
Fuel 460 T5 Spread To verify the proper calculation of the T5 spread from max to min for
display and data logging purposes.
TE39
Fuel 470 T5 Thermocouple Failure To verify the annunciation when thermocouple failure is detected and
that action is taken for multiple thermocouple failure.
TE39
Fuel 480 Lite Around Failure To Verify the monitoring of individual thermocouples during light off
sequence.
TE39
Fuel 500 T5 Set Point To verify the T5 control of the fuel control system.
TE39
Fuel 510 T5 Peak Offset To verify that the T5 temperature topping set point is offset for island
mode operation and sets the delayed shutdowns equal to the normal on-
TE39
grid topping limit.
Fuel 520 Start Ramp Suspend To verify the proper indication to suspend start ramp during acceleration.
TE39
Fuel 540 T5 Alarm and Shutdowns To verify the high T5 temperature protection as required.
TE39
Fuel 555 Gas Fuel Main Flow Calculated To verify the proper calculation of the gas fuel main flow.
TE39
Fuel 560 Gas Fuel DP Control To verify the gas fuel DP control of the gas fuel control system.
TE39
Fuel 590 Gas Fuel Start Ramp To verify the proper calculation of light off and start ramp signals for fuel
control during ignition and acceleration for gas fuel applications.
TE39
Fuel 600 Liquid Fuel Start Ramp To verify the proper calculation of light off and start ramp signals for fuel
control during ignition and acceleration for liquid fuel applications.
TE39
Fuel 610 Maximum Fuel Limiting To verify the proper calculation for maximum fuel limiting.
TE39
Fuel 630 Minimum Fuel To verify the proper calculation of minimum fuel.
TE39
Fuel 650 Fuel Min Max PI Control To verify the proper error and control mode selection.
TE39
Fuel 660 Fuel Control Mode Indication To verify the proper mode indication for fuel control.
TE39
Fuel 670 Fuel Control Signal To verify the proper determination of fuel control signal.
TE39
Fuel 675 Fuel Signal Compensation To verify the proper control of the gas fuel valve signal compensation.
TE39
Fuel 680 Gas Fuel High Force or Low To verify the proper control of the gas fuel high force, low force actuator
Force Actuator or CCC or CCC Controller.
TE39
Controller
Fuel 690 Liquid Fuel Valve To verify the proper interface for the liquid fuel valve.
TE39
Fuel 700 Fuel Signal Delta To verify the proper calculation of the difference in fuel command
between scans as well as between every six scans.
TE39
Fuel 840 Engine Guide Vane Control To verify the proper guide vane control during start and run modes.
TE39
Fuel 850 Inlet Guide Vane Control To verify the proper control of the inlet guide vane.
TE39
Fuel 870 Bleed Valve Control To verify the proper bleed valve control during start and run modes.
TE39
Fuel 880 Bleed Valve Actuator To verify the proper opening and closing of the bleed valve.
TE39
Fuel 890 Igniter and Torch To verify the proper control of Igniter and Torch.
TE39
Generator Generator Program Inputs (from To verify the CGCM inputs and appropriate annunciation on
010 CGCM's) communication failure.
TE39
Generator Switchgear Malfunction and To verify Switchgear Malfunction and Differential Or Ground Fault
020 Differential Or Ground Fault shutdowns annunciations are present.
TE39
Generator CGCM Read/Write To verify the CGCM’s configuration and unscheduled read/write
040 communication.
TE39
Generator Generator Load Speed modes To verify the proper selection of the generator load control modes.
080 TE39
Generator Load Control Mode Status To verify the proper load control mode status indication.
090 TE39
Generator Generator Percent KW To verify the proper calculation of Generator Percent KW.
100 TE39
Generator KW / Import / Export control To verify the proper function of KW / Import / Export options.
110 options TE39
Generator kW Load Control PI To verify the proper load control bias proportional integral control.
140 TE39
Generator Speed Droop Bias To verify the proper calculation of the speed droop bias offset.
150 TE39
Generator Generator Load Share Bias To verify the load share bias input from CGCM.
160 TE39
Generator Synchronize Bias To verify the proper calculation of the speed autosync bias offset.
180 TE39
Generator Load Control Initialize To verify the proper initialization of the load and speed set point for
190 control mode transfer.
TE39
Generator Load Set Point To verify the proper calculation of the load control speed set point.
200 TE39
Generator Protective relays To verify the proper function of the CGCM protection relays.
210 TE39
Generator kVAR Power Factor Set points To verify the proper adjustment of CGCM set points for power factor and
240 kVAR control modes.
TE39
Generator Excitation Control Set points To verify the Excitation control set points
250 TE39
Generator Voltage modes selection To verify the proper Voltage mode selection
260 TE39
Generator Voltage Regulator Excitation To verify the proper function of the excitation control.
270 Control TE39
Generator CGCM Fault Output To verify synchronization of CGCM configuration bits for fault detection
295 to CGCM outputs.
TE39
HMI 010 Common PGM Inputs To verify the proper function of the HMI inputs from other programs,
which are common to all applications.
TE39
HMI 020 Off Loc Aux Selection To verify the proper function of selection for Off, Local, Auxiliary, and
Remote operation.
TE39
HMI 025 Off Local Aux Remote Mode To verify the proper logic for Aux, Local, and Remote mode selection.
TE39
HMI 030 Off Skid Turbine Control Panel To verify the proper function of the Off Skid Turbine Control Panel Inputs.
Inputs TE39
HMI 040 On Skid Turbine Control Panel To verify the proper function of the On Skid Turbine Control Panel Inputs.
Inputs TE39
HMI 050 Turbine Control Panel To verify the proper function of processes IO common to Oil and Gas
Gen Sets with a local off skid Turbine Control Panel
TE39
HMI 055 TCP Off Skid GS Local To verify the proper function of processes IO common to Oil and Gas
Gen Sets with a Local on skid Turbine Control Panel
TE39
HMI 070 On-Skid Control Box To verify the proper temperature monitoring inside the on-skid control
Temperature box.
TE39
HMI 100 Terminal Common Commands To verify the proper function of the terminal common commands from
local, aux and remote displays.
TE39
HMI 110 Terminal Common Commands To verify the proper function of the terminal common driven commands
[Driven] from local, aux and remote displays.
TE39
HMI 160 Remote Hardwire Inputs To verify the proper function of the Remote hardwire Generator
Generator commands.
TE39
HMI 170 Remote Hardwire Voltage To verify the proper function of the Remote hardwire Voltage Adjust.
Adjust TE39
HMI 200 Start Hour Meter To verify the proper function of Start and Hour Meters.
TE39
HMI 210 Auto Start and Auto Sync To verify the proper function of the Auto-start/sync commands.
TE39
HMI 260 HMI commands To verify that operator commands affecting the generator program are
processed properly.
TE39
HMI 450 Starter VFD Configuration To verify the configuration request command for the Starter VFD can be
Command activated from the display.
TE39
HMI 460 Slow Roll Command To verify slow roll command(s) can be activated from the display.
TE39
HMI 516 Liquid PCD Fwd Purge To verify Commands for Liquid Fuel Manifold PCD Forward Purge
TE39
HMI 528 TCP Fuel Select Switch Local To verify functionality of the fuel select switch signal from an off skid
local turbine control panel in the controls system.
TE39
HMI 530 Dual Fuel Commands To verify the operator interface commands related to the dual fuel option.
TE39
HMI 540 Enclosure Driven Vent Fan To verify the proper processing of commands for selecting the active
Select enclosure driven vent fans.
TE39
HMI 550 Enclosure Vent Fan Select To verify proper processing of commands for selecting the active
enclosure vent fan.
TE39
HMI 560 On Crank Water Wash To verify proper processing of commands related to the On Crank Wash
Option.
TE39
600
500
400
300
200
100
0
0 2 4 6 8 10 12 14 16 18
TIME (MINUTES)
TEMPERATURE
100 MAXIMUM
80 TEMPERATURE
TEMPERATURE
(DEGREES F)
60
76.3
40
20
0
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00
TIME (MINUTES)
Part Number: 301504-101 Start Date: 22-Jul-08 First Pressure Reading: 797.6
Test Pressure (PSI): 780+/-20 PSI Start Time: 4:45 PM Last Pressure Reading: 792.3
Serial Number: JUL08-38870 Finish Date: 22-Jul-08 Maximum Test Pressure: 797.8
Time Between Measurements: 1 MINUTE Finish Time: 5:00 PM Minimum Test Pressure: 792.1
Operator: SABINO URIETA
Test Pressure Difference: 5.7
Comments:
2. X-RAY REPORT
THIS FUEL RING MANIFOLD DOES NOT CONTAIN
The following rotors and their supporting documents for Engine Serial # 0560B, PD #3C841, have been
reviewed to ensure that they are in accordance with Solar standards, drawings, specifications and
practices and Quality requirements.
Compressor Rotor
Mechanical/Electrical 05.04.A P/N 330171-100 S/N ROG08-46780
Balance 05.04.D P/N 330171-100 S/N ROG08-46780
GP Rotor
Mechanical/Electrical 05.04.B P/N 304498-100 S/N ROG08-46485
Balance 05.04.E P/N 304498-100 S/N ROG08-46485
SECTION: 05.04.A
INSPECTION DATA
Dimensional summary sheet for serial number: ROG08-46780
September 2, 2008
Page 1 of 1
Dimension Description Op# Result Minimum Maximum Red Badge Date Initials Red Sign Off
2AFTTOOL AFT HUB AROBOTEC DIA 0050 .0001 0 .0002 45917 02-AUG-08
2FWDTOOL FWD CONE AROBOTEC DIA 0050 .00015 0 .0002 45917 02-AUG-08
2RO0 STG 0 LAB SEAL R/O 0050 .0005 0 .003 45917 02-AUG-08
2RO00 STG 00 LAB SEAL R/O 0050 .0012 0 .003 45917 02-AUG-08
2RO00AN STG 00 ANGLE 0050 45 0 360 45917 02-AUG-08
2RO0AN STG 0 ANGLE 0050 45 0 360 45917 02-AUG-08
2RO1 STG 1 LAB SEAL R/O 0050 .0015 0 .003 45917 02-AUG-08
2RO10 STG 10 SPACER R/O 0050 .0019 0 .003 45917 02-AUG-08
2RO10AN STG 10 ANGLE 0050 45 0 360 45917 02-AUG-08
2RO11 STG 11 SPACER R/O 0050 .0014 0 .003 45917 02-AUG-08
2RO11AN STG 11 ANGLE 0050 90 0 360 45917 02-AUG-08
2RO12 AFT HUB SPACER R/O 0050 .0014 0 .003 45917 02-AUG-08
2RO12AN AFT HUB ANGLE 0050 0 0 360 45917 02-AUG-08
2RO1AN STG 1 ANGLE 0050 0 0 360 45917 02-AUG-08
2RO2 STG 2 LAB SEAL R/O 0050 .0009 0 .003 45917 02-AUG-08
2RO2AN STG 2 ANGLE 0050 0 0 360 45917 02-AUG-08
2RO3 STG 3 SPACER R/O 0050 .0017 0 .003 45917 02-AUG-08
2RO3AN STG 3 ANGLE 0050 90 0 360 45917 02-AUG-08
2RO4 STG 4 SPACER R/O 0050 .0012 0 .003 45917 02-AUG-08
2RO4AN STG 4 ANGLE 0050 0 0 360 45917 02-AUG-08
2RO5 STG 5 SPACER R/O 0050 .0015 0 .003 45917 02-AUG-08
2RO5AN STG 5 ANGLE 0050 45 0 360 45917 02-AUG-08
2RO6 STG 6 SPACER R/O 0050 .0026 0 .003 45917 02-AUG-08
2RO6AN STG 6 ANGLE 0050 0 0 360 45917 02-AUG-08
2RO7 STG 7 SPACER R/O 0050 .0019 0 .003 45917 02-AUG-08
2RO7AN STG 7 ANGLE 0050 0 0 360 45917 02-AUG-08
2RO8 STG 8 SPACER R/O 0050 .0011 0 .003 45917 02-AUG-08
2RO8AN STG 8 ANGLE 0050 0 0 360 45917 02-AUG-08
2RO9 STG 9 SPACER R/O 0050 .0018 0 .003 45917 02-AUG-08
2RO9AN STG 9 ANGLE 0050 45 0 360 45917 02-AUG-08
2ROCONE CONE 7" DIA R/O 0050 .001 0 .003 45917 02-AUG-08
2ROCONEAN CONE ANGLE 0050 315 0 360 45917 02-AUG-08
BRG1E FWD CONE ELECT R/O 0050 .02 0 .05 45917 02-AUG-08
BRG1M FWD CONE MECH R/O 0050 .0001 0 .0002 45917 02-AUG-08
BRG2E AFT HUB ELECT R/O 0050 .01 0 .05 45917 02-AUG-08
BRG2M AFT HUB MECH R/O 0050 .00005 0 .0002 45917 02-AUG-08
INSPECTION DATA
Dimensional summary sheet for serial number: ROG08-46485
September 2, 2008
Page 1 of 1
Dimension Description Op# Result Minimum Maximum Red Badge Date Initials Red Sign Off
BT1B BEARING JOURNAL DIA. 0005 3.4999 3.4997 3.5 27057 01-AUG-08
CT1B SHAFT SEAL DIA. 0005 4.365 4.363 4.367 27057 01-AUG-08
CT2B LABYRINTH SEAL DIA. 0005 8.3349 8.334 8.336 27057 01-AUG-08
CT3B LABYRINTH SEAL DIA. 0005 8.4749 8.474 8.476 27057 01-AUG-08
CT4B LABYRINTH SEAL DIA. 0005 8.615 8.614 8.616 27057 01-AUG-08
CT5B LABYRINTH SEAL DIA. 0005 8.7549 8.754 8.756 27057 01-AUG-08
CT6B LABYRINTH SEAL DIA. 0005 8.8948 8.894 8.896 27057 01-AUG-08
INCH MECHANICAL RUN-OUT 0005 .00015 0 .0002 44885 01-AUG-08
KTA CURVIC ADDEMDUM 0005 .0585 .057 .061 27978 01-AUG-08
VOLTS ELECTRICAL RUN-OUT 0005 .02 0 .05 44885 01-AUG-08
INSPECTION DATA
Dimensional summary sheet for serial number: ROG08-46780
September 2, 2008
Page 1 of 1
Dimension Description Op# Result Minimum Maximum Red Badge Date Initials Red Sign Off
AMTAFT2 AFTER GRIND AFT IMBALANCE 0055 3.01 0 6 45917 02-AUG-08
AMTFWD2 AFTER GRIND FWD IMBALANCE 0055 3.31 0 6 45917 02-AUG-08
ANGAFT2 HEAVY ANGLE 0055 63 0 360 45917 02-AUG-08
ANGFWD2 HEAVY ANGLE 0055 8 0 360 45917 02-AUG-08
INSPECTION DATA
Dimensional summary sheet for serial number: ROG08-46485
September 2, 2008
Page 1 of 1
Dimension Description Op# Result Minimum Maximum Red Badge Date Initials Red Sign Off
DEG-E ANGLE LOCATION 0050 95 0 360 27385 04-AUG-08
DEG-G ANGLE LOCATION 0050 120 0 360 27385 04-AUG-08
INCH-A RUNOUT STG 3 DISC 0050 .001 0 .003 26844 03-AUG-08
INCH-C RUNOUT STG 1 DISC 0050 .001 0 .003 26844 03-AUG-08
OZIN-E IMBALANCE STG #1 0050 .0985 0 .16 27385 04-AUG-08
OZIN-G IMBALANCE STG #3 0050 .0868 0 .16 27385 04-AUG-08
GEAR BOX
INSPECTION DATA
THE GEAR BOX IS DYNAMICALLY
TESTED WITH THE TURBINE
DURING PACKAGE TEST. ALL TEST
DATA IS LOCATED IN ITEM 05.07.
SECTION: 05.07
NO DOCUMENTS REQUIRED
SECTION: 07.05
DIMENSIONAL CHECK
NO DOCUMENTS REQUIRED
SECTION: 10.01
Bumi Armada
This ITP was Prepared By: Larry Proctor, Quality Engineer
Equipment includes 2 Each, Taurus GS Package(s). Powered by Taurus 70-10301 turbine(s).
FOURTEEN (14) Working Days Notification Required For All Customer INSPECTION/OBSERVATION Items.
'O1' Indicates Customer, Third Party or Certifying Agency inspection on 100% of units, operations or tests on that project. Every
effort is made to have the inspector present when these operations are conducted. The inspection or test has not necessarily
been performed in advance, prior to the observation point. Should the inspector be unavailable at the time of the actual
inspection or test, production is not stopped. Review of verifying documents is included. Equipment in ITP Section 1.0 shall be
released if Customer's Inspector fails to respond or fails to appear.
'O2' Identical to 'O1', but performed on a sampling of units, operations or tests on that project (not necessarily 100%). Every effort is
made to have the inspector present when these operations are conducted. The inspection or test has not necessarily been
performed in advance, prior to the observation point. Should the inspector be unavailable at the time of the actual inspection or
test, production is not stopped. Notification requirements are the same as for '01'. Equipment in ITP Section 1.0 shall be
released if Customer's Inspector fails to respond or fails to appear.
'A1' Indicates Solar inspection or test on 100% of units, operations or tests on that project.
'A2' Indicates Solar inspection or test on only a sampling of units, operations or tests on that project.
'R1' Indicates an in-process document review is required on 100% of units on that project. The in-process review is to take place at
the operation or test location unless the document is included in the databook. A copy of the verifying document is not supplied
unless also identified with an 'X' in Solar's column 'A'.
'R2' Indicates an in-process document review is required on only a sample of units on that project. The in-process review is to take
place at the operation or test location unless the document is included in the databook. A copy of the verifying document is not
supplied unless also identified with an 'X' in Solar's column 'A'.
'M2' Indicates a sample monitoring of Solar's system is required. This monitoring will be on random equipment, and may not be
project specific.
'X' In Solar's column 'A' indicates a copy of the document will be supplied in the Project Quality Assurance Data Book. The
Databook contains a reference copy of the ITP. Individual documents are identified with the ITP Item number and are found in
the corresponding sections. The documents consist of supplier information and Solar information.
Note:
For Solar source inspections, only a Quality Engineer, Quality Manager, or Project Manager can waive
source inspection requirements.
For customer inspections, only the customer can waive source inspection requirements. All waivers must
be in writing (email or faxed).
0.0 ITP approval by Solar Project Management. 0.4 COLUMN C CONTACT INFORMATION:
Company:
DATE: Contact:
Ray Newson, Project Manager Phone #:
Newson_Ray_P@solarturbines.com
Fax #:
Eric Stallings, Project Engineer Cell/Pgr#
stallings_eric_a@solarturbines.com
Email:
lemke_fred_l@solarturbines.com Fax #:
Cell/Pgr#
Email:
01.01 RECEIVING INSPECTION - Inspect material per Solar Quality BAAN Material A2
Solar practices Management System
System
SUPPLIERS BELOW TO NOTE THE
Engineering
FOLLOWING:
Drawings
ALL DOCUMENTATION MARKED WITH 'X' IN
Purchase Order
COLUMN A SHALL BE PROVIDED TO SOLAR
WITHIN 14 CALENDAR DAYS OF
COMPLETION OF MANUFACTURING, AND/OR
FINAL SOLAR OR CUSTOMER INSPECTION.
DOCUMENTATION SHALL INCLUDE SOLAR
PO #, SOLAR PART NUMBER AND SOLAR
PROJECT NAME/NUMBER.
ELECTRONIC TRANSMITTAL OF
DOCUMENTS IS PREFERRED. SEND TO:
Solar_quality_documents@solarturbines.com
Purchase Order
Purchase Order
Purchase Order
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
3. Electrical R1 X
Device Certificates
4. ABS Certificate R1 X
Purchase Order
4. ABS Certificate R1 X
01.13 INTERNAL EQUIPMENT HANDLING SYSTEM Purchase Order 1. Proof Load Test R1 X O1
Records
ES2335
ABS Certified
Engineering 2. ABS Certificate R1 X
(Includes engine handling kit trolley beam(s), Drawings
engine handling kit external structure(s), start
motor removal kit trolley beam(s), start motor
removal external structure(s), hoists, jib crane,
and field tools, as applicable)
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
(TURBINE PACKAGE)
(TurboFab, Houston)
02.04 Lube Oil Tank - Pneumatic Leak Test TurboFab Quality Traveler A1 X O1
Management
System
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
03.06 Hydrostatic Pressure Test of Manifolds Solar Quality Hydro Test Log A1 X M2
Management
(1.5 times design pressure for 10 minutes System
minimum)
Engineering
Package manifolds are manufactured and leak Drawings
tested at Solar facilities in San Diego, CA & ASME B31.3
Tijuana, Mexico.
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
04.01 Visual Inspection of Control Console Wiring Project Electrical Control Console A1 X
Drawings Hardware Sheet in
04.02
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
05.03.A Compressor Case Leak Test Shop Floor Leak Test Chart A1 X O1
Information System
Cases are leak tested at the place of
manufacture. Cases are not assigned to a Engineering
specific project or a specific engine at the time of Drawings
leak testing.
05.03.B Combustor Case Leak Test Shop Floor Leak Test Chart A1 X O1
Information System
Cases are leak tested at the place of
manufacture. Cases are not assigned to a Engineering
specific project or a specific engine at the time of Drawings
leak testing.
05.03.C Engine Fuel Manifold Hydrostatic Test Shop Floor 1. Hydrostatic Test A1 X R1
Information System Chart
100% Radiography
ES 9-78 2. X-Ray Report R1 X
Manifolds are manufactured and leak tested at Engineering
Turbotec in Tijuana, Mexico. Drawings
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
05.04.D Balance Gas Producer Compressor Rotor Shop Floor Inspection Data A1 X O1
Information System
Engineering
Drawings
05.04.E Balance Gas Producer Turbine Rotor Shop Floor Inspection Data A1 X O1
Information System
Engineering
Drawings
Utilizing the Facility Test Stand and TMP & PSO Quality
Dynamometer to load engine Management
System
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
08.02 Enclosure Assembly Static Test Solar Quality Stamp Off Sheet A1 X O1
Management in 08.01
(Including simulated test of fire and combustible System
gas system (if present)).
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
09.05 Package Preservation And Preparation For Solar Quality OK to Ship QC Tag A1 O1 O1
Shipment Management
System
Shipping/Traffic
Functional Practices
ES 9-249
ES 9-248
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
B 06/16/08 Larry Proctor Revision B: Added O1's in items 02.03, 02.04, 04.02, 05.03.A, 05.03.B, 05.04.D, 05.04.E, 07.05, 08.02,
09.05. Added customer contact information in column B and D. Added radiography for liquid fuel
manifolds.
D 08/25/08 Larry Proctor Revision D: Removed DPS contact names from column B.
A1 SOLAR 100% INSP/TEST R1 100% DOCUMENT REVIEW O1 100% OBSERVE INSP/TEST X SOLAR SUBMIT
VERIFYING DOCUMENT
A2 SOLAR SAMPLE INSP/TEST R2 SAMPLE DOCUMENT REVIEW O2 SAMPLE OBSERVE INSP/TEST M2 MONITOR SYSTEM
- This device list contains electrical components associated with the turbine control console and turbine skid.
- Column headings:
"REF DES" The reference designator is used to identify each device as follows. The first 1 or 2
letters designates the type of component. (B = Motor, DS = Light) The number following
the letters indicates the location. (2 = Control boxes, 3 = Turbine skid)
"MANUFACTURER P/N" Part number specified by manufacturer or supplier as reference for certification.
"CERTIFICATION" Lists one or more of the certifying agencies, list number, file number, or certificate
number.
- Note 1: The RTD's, thermocouples and magnetic pickups are sealed units with wiring in rigid conduit and EP boxes. The RTD's monitoring
liquid temperature are in thermowells. RTD's, thermocouples and magnetic pickups are considered integral to the turbine package
and therefore included in the CSA LR35592 and LR26165 Certification series.
CSA
MANUFACTURER CERTIFICATION
ISA TAGS DESCRIPTION MANUFACTURER/ COMPANY CERT DIV 1 DIV 2 ORDINARY COMMENTS REV
P/N
CLASS
HORN/STROBE FIRE
YA8001 CLIFFORD AND SNELL MODEL YL60 UL: UGKZ.E161818 X
WARNING
MOTOR PRE/POST LUBE FRAME SIZE
M6010 RELIANCE ELECTRIC CSA: LR19467 4228-81 X
PUMP MOTOR, AC 184T
MODEL 36
M6020 MOTOR BACKUP LUBE OIL BALDOR ELECTRIC FRAME SIZE UL: PTDR.E6951 X
182
FRAME SIZE
M6110 MOTOR SCAVENGING SUPPLY BALDOR ELECTRIC CSA: LR6771 4228-81 X
56
FRAME SIZE
M6111 MOTOR SCAVENGING SUPPLY RELIANCE ELECTRIC CSA: LR63415 4228-01 X
56
FRAME SIZE
M5005 MOTOR STARTER RELIANCE ELECTRIC CSA: LR19467 4228-01 X
405T
MOTOR MAIN FUEL PUMP FRAME SIZE
M7530 RELIANCE ELECTRIC CSA: LR19467 4228-81 X
DRIVE 254
LIGHT SOURCE
SL8001 R. STAHL MODEL 6408 CSA: LR09948 3428-03 X
FLUORESCENT
SV7050 RELAY CONTROLLER ACTIVE VERSA PRODUCTS MODEL VOE26 UL: VAPT.E37068 X
SV7055 RELAY CONTROLLER ACTIVE BIFOLD MODEL FP10P CSA: LR215681 3228-81 X
SV7550 RELAY CONTROLLER ACTIVE VERSA PRODUCTS MODEL VOE26 CSA: LR45277 3228-01 X
S301XH16V3BC
SV7542 RELAY CONTROLLER ACTIVE GC VALVES UL: YTSX.E157477 X
3E
RELAY GROUND FUSE BLOWN S301XH16V3BD
SV7561 GC VALVES UL: YTSX.E157477 X
ALARM 5E
RELAY NO EMERGENCY
SV7540 VERSA PRODUCTS MODEL VOE23 UL: VAPT.E37068 X
SHUTDOWN SUMMARY
RELAY NO EMERGENCY
SV7560 VERSA PRODUCTS MODEL VOE53 UL: VAPT.E37068 X
SHUTDOWN SUMMARY
RELAY NO EMERGENCY
SV1001 VERSA PRODUCTS MODEL VOE23 UL: VAPT.E37068 X
SHUTDOWN SUMMARY
"# $! %&'(''
67 / 8
!% &9
% 8 % - &: & ; ; < %"= ; %
) * **
< 9
,
9 < ,19
. ,
9
09-. 3 . ) )< .
! !
" ! # $ % &' ( ' $ % &
) ) ( * ) ( ) )) )* # + , - ) . / ) * )
* * * $ % &. ' ' ' ) $ % &
) " ) " ( * ) ( ) )) )* + , - ) . / ) * ) *
* * $ % &. ' ' ' ) $ % &
) 0 ( * ) # - ) . / ) * ) * * * $ % &.
' ' ' ) $ % &
) 0 " ( * ) ( ) )) )* # + , - . / ) * ) *
* * $ % &' ' ' ) $ % &
" 0 ) * ( ) )) )* # + 1 ,- 2 3 /
! ! !* # $ % &. ' ' $ % &
! 0 " *
+ , ! " # ! ! ! # $ % &' ( ' $ % &
) ) ( * ) ( ) )) )* 1 ) . / ) * ) *
* * $ % &. ' ' ' ) $ % &
) " ) " ( * ) ( ) )) )* 1 ) . / ) * ) * *
* $ % &. ' ' ' ) $ % &
) 0 ) 0 ( * ) ) . / ) * ) * * * $ % &.
' ' ' ) $ % &
) ) ( * ) ( ) )) )* # + 1 , - ) . / ) * )
* * * $ % &. ' ' ' ) $ % &
) " ) " ( * ) ( ) )) )* + 1 , - ) . / ) * )
* * * $ % &. ' ' ' ) $ % &
) 0 ) 0 ( * ) # - ) . / ) * ) * * *
$ % &. ' ' ' ) $ % &
) " 0 ( * ) ( ) )) )* # + 1 , - . / ) * )
* * * $ % &' ' ' ) $ % &
) ) ) ) ) ) ) ) ) ) ( * ) ( ) )) )* #
- ) . / ) * ) * * * - - -) - -* - 2 2) 2* $ % &. ' '
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=YTSX.E157477&... 8/14/2006
YTSX.E157477 - Valves, Electric for Use in Hazardous Locations Page 2 of 2
' ) $ % & 5
) ) 0 ) 0 ) 0 ) 0 ) ) 0 ) 0 ) 0 ) 0 ( * ) # - )
. / >1 ) * ) * * * - - -) - -* - 2 2) 2* $ % &. ' ' ' )
$ % & 5
" 0 ( * ( ( ) )) )* # + 1 ,- 2 3 /
! ! !* # $ % &. ' ' $ % &
5 0 ?@ ?: &: ( 7( % 8 &&?;& $
<$ % )4 4
J % K ; ;& 8 67 ,$
$? 7( A <% B @ 9
%;C
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=YTSX.E157477&... 8/14/2006
WOYR2.E12252 - Switches, Special Use - Component Page 1 of 51
WOYR2.E12252
Switches, Special Use - Component
Page Bottom
L, M, N, P, R or S, f/b B, G
or W, f/b A, B, C or E, f/b
2 or 3, f/b A, B, C or E, f/b
f/b B, G, or W, f/b B, C, D,
E, F, H, J, K, L, M, R, S, T,
W or X, f/b 2, 3, 8 or 9,
f/b B, G or W, f/b A, B, C or
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 2 of 51
B, G, or W, f/b A, B, C or E,
f/b L93
f/b B thru H, K, L, M or P,
f/b L93
AML32F100-L93 L93
G or W, f/b A, B, C or E, f/b
L186 or L205.
W, f/b B, C, F, M or P, f/b 4
Q, T, V or X, ww/o numbers,
or L225
L, M, N, Q, S, T, V, W or X,
L17 or L33
ww/o B, D, K, L, N, Q, R, T,
-5R, ww/o B, D, L, N, P, Q,
BA-5R276-A2-L272 L272
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 3 of 51
B, D, L, M, N, P, Q, R, T, V
or L208
ww/o A, B, D, L, M, N, P, Q,
R, S, T, V or X, ww/o
R or W, f/b 1 thru 4
-1R, ww/o D, L, M, N, Q, S, T
BM-R252-L167 L167
A, B, D, L, M, N, Q, S, T, V or L268
L, M, N, P, Q, R, S, W, X or a
L, M, N, Q, R, S, T, W or X, or
letter A, B, D, K, P, PC, PP or
L96, or L233.
D, L, M, N, Q, S, T, W or X, or
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 4 of 51
letter A, B, D, K, P, PC, PP or
f/b D, L, M, N, Q, R, S, T or
W, or a combination of these
hyphenated letter A, B, D, K,
P, PC or PP, or T without a
D, L, M, N, Q, R, S, T, W or
X, or a combination of these
hyphenated letter A, B, D, K,
P, PC, PP or T, or TC without
hyphen)
L95 or L169.
S, T, W or X, or a combination of these
A, B, D, K, P, PC, PP or T, or TC without a
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 5 of 51
-3, f/b D, L, M, N, Q, R, S, T or W, or a
N, Q, S, T or W, or a combination of these
letter A, B, D, K, P, PC or PP, or T
BZ-R241 or BZ-R2418-A2 L4
f/b L4
BZ-R814-PP1-L189 L189
f/b L169
f/b D, K, L, M, N, Q, S, T,
W or X or a combination of
D, K, P, PC, PP or T or TC
f/b D, L, M, N, Q, S, T,
or W, or a combination of
D, K, P, PC, PP or T,
f/b D, L, M, N, Q, R, S, T,
W or X, or a combination of
D, K, P, PC or PP or T,
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 6 of 51
D, E, L, M, N, Q, R, S, T
or W, or a combination of
D, K, P, PC, or T, or TC
N, Q, S, T or W, or a
L180
Q, R, S, T or W, or a
letter A, B, D, K, P, PC or
N, Q, R, S, T or W, or a
letter A, B, D, K, P, PC or
L87
-7, f/b D, L, M, N, Q, R, S,
T or W, or a combination of
D, K, P, PC or PP, or T without
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 7 of 51
M, N, Q, R, S, T, W or X, or a
letter A, B, D, K, P, PC or
N, Q, S, T or V, ww/o numerals,
L, Q, N, S or V, ww/o numerals,
L, M, N, P or W, f/b 2 or 3, f/b
L, M, N, P or W, f/b 2 or 3, f/b
f/b L222
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 8 of 51
f/b F, G, H, K, M, P, R or W,
N, P or W, f/b 2 or 3, f/b AA
P, f/b A, B, C, K, L, M, N, P
L243
f/b A, B, C, K, L, M, N, P or
F, H, K, P, R or W, ww/o NC,
NY or XX, ww/o A, B or X,
L223
2 or 3
OP, Types AL, ALH, AR, ARH, CL, CLH, L1, L2, L4
OPD, Types AL, ALM, AR, ARH, CL, CLH, L10 or L59
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 9 of 51
11, 12, 21, 22, 23, 51, 101, L149, L150, L151
designation H, S or T, ww/o
V3- or V3L- f/b 1 thru 99, 201 L22, L29, L83, L86, L112, L116,
thru 299, 401 thru 499, 601 L118, L156, L251 or L259
V3- or V3L- f/b 101 thru 199, 301 L22, L29, L112, L116, L156,
L206 or L291
L112
Note: #Followed by 1, 2 or 3, f/b 0 thru 4, 7, 8, 9 or A, f/b D8, D9 , E7, E8, E9, P01 thru P99 or S6, ww/o numbers and/or letters.
V3-1055-L206 L206
V3- or V3L-, f/b 1101 thru 1199, L22, L29, L93, L112, L116, L131
V3-1909-D8-L228. L228
-L186 or V3L-1949-L186.
V3-, f/b 1981 or 1983, f/b -D8, f/b L86, L113 or L259
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 10 of 51
V3L-2100-L201 L201
V3- or V3L-, f/b 2101 thru 2199 or L22, L29, L99, L131 or L201
V3-2100-D963-L216 L216
V3-or V3L- f/b 2401 thru 2599#, f/b L22, L22, L109, L162,
V3L-2453-D8-L200 L200
V3- or V3L- f/b 3001 thru 3099, 3101 L22, L29, L83, L86,
f/b L226
f/b L232
V3L-73317-D8-L22 L22
V3L-70009-D9-L118 L118
V4-61-L4 L4
f/b L162
f/b L215
Note: #Followed by 1, 2 or 3, f/b 0 thru 4, 7, 8, 9 or A, f/b D8, D9, E7, E8, E9, P01 thru P99 or S6, ww/o numbers and/or letters.
Note: #Followed by 1, 2 or 3, f/b 0 thru 4, 7, 8, 9 or A, f/b D8, D9 , E7, E8, E9, P01 thru P99 or S6, ww/o numbers and/or letters.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 11 of 51
Note: #Followed by 1, 2 or 3, f/b 0 thru 4, 7, 8, 9 or A, f/b D8, D9 , E7, E8, E9, P01 thru P99 or S6, ww/o numbers and/or letters.
or S6,ww/o numbers
f/b L264
L242 or L258
B, D, L, N, P, Q,
T, V or X, OCO/TL, ww/o
numbers ww/o A, B, D,
WA-1RX123-A4-L22 L22
WM-1R11-L102 L102
D, L, M, N, Q, R, S, T
or W, or a combination of
letter A, B, D, K, P,
PC or PP, or T without
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 12 of 51
WZ-Refer to BZ Series —
for details
YZ(Refer to BZ Series —
for details
hyphenatedsuffix numbers,
f/b L305
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 13 of 51
1PB501-L4 L4
of up to 5 letters and/or
up to 5 letters and/or
and/or numerals,
f/b L192
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 14 of 51
2AC, 3AC, 4AC or 13AC f/b 1 thru L22, L83, L86, L116, L118,
f/b L25
2VP f/b 1 thru 999#, f/b L22, L83, L22, L83, L86, L112,
2VP48-L183 L183
Note: #Followed by 1, 2 or 3, f/b 0 thru 4, 7, 8, 9 or A, f/b D8, E7, E8, E9, P01 thru P99 or S6, ww/o numbers and/or letters.
f/b L22
4A, f/b 1 thru 99, f/b a letter, L4, L22, L171 or L285
G, R, S, W or Y, f/b J, K, L,
or L171.
numbers, f/b L4
L151
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 15 of 51
numbers, f/b L7
6AS-5, -13, -18, -21, -32, -34, L1, L4, L9, L22, L23, L58
L111
f/b L86
letter B, L, Q, R or V, f/b
L115
f/b L62
thru 7VP34
8AC29-UL L151
f/b L128
9SX1-H58 L7
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 16 of 51
L4 or L122
f/b L191
22AC, 23AC or 24AC f/b 1 thru 99, L22, L83, L86, L116, L118,
L163 or L195
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 17 of 51
41TB-5-3-L25 L25
f/b L62
f/b L191
f/b L191
402AC f/b 1 thru 99, ww/o suffix L22, L117, L156, L162, L163
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 18 of 51
590-096 L83
2 30 DC —
2 250 60 —
0.1 30 DC —
0.1 250 60 —
0.1 30 DC —
0.1 250 60 —
0.1 30 DC —
2 30 DC —
2 250 60 —
V9-16 16 125/250 60 —
B, C, D, E, F, H, P or S, Res 125/250 60 —
10.1
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 19 of 51
f/b A, B, C, D, F, H or S,
f/b D or W, f/b 1, 3 or 4,
— 125-250 60 1/2
311SM2-T, 311SM6-T 4 24 60 —
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 20 of 51
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 21 of 51
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 22 of 51
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 23 of 51
15.1A, 12UDC.
15.1A, 12UDC
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 24 of 51
0.1A, 30V, dc
L303 22A, 125-250-277V, ac; L311 10A, 277V, ac, 20A, 125V, ac
ZM1 6A 125/250 60 —
f/b -10,-50,-60;
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 25 of 51
Marking: Company name or tradenames "MICROSWITCH", "MICRO", "HONEYWELL", electrical rating, and UL Recognized Component Mark on switch. Catalog designation on
switch or smallest container.
L, M, N, P, R or S, f/b B, G
or W, f/b A, B, C or E, f/b
2 or 3, f/b A, B, C or E, f/b
Note 1. The switches are suitable for multiple circuit conditions where opposite polarity exists except switches having suffix "P".
f/b B, G, or W, f/b B, C, D,
E, F, H, J, K, L, M, R, S, T,
W or X, f/b 2, 3, 8 or 9,
f/b B, G or W, f/b A, B, C or
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 26 of 51
B, G, or W, f/b A, B, C or E,
f/b L93
f/b B thru H, K, L, M or P,
f/b L93
AML32F100-L93 85 2/1 PP 6K 2
Note 1. The switches are suitable for multiple circuit conditions where opposite polarity exists except switches having suffix "P".
G or W, f/b A, B, C or E, f/b
W, f/b B, C, F, M or P, f/b 4
Note 1. The switches are suitable for multiple circuit conditions where opposite polarity exists except switches having suffix "P".
or L225
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 27 of 51
L, M, N, Q, S, T, V, W or X,
L17 or L33
+When these switches are followed by suffix "TP", they should not exceed a temperature of 85 C, and if they are marked with letter "T" in a circle, they should not exceed a
temperature of 150 C.
ww/o B, D, K, L, N, Q, R, T,
-5R, ww/o B, D, L, N, P, Q,
+When these switches are followed by suffix "TP", they should not exceed a temperature of 85 C, and if they are marked with letter "T" in a circle, they should not exceed a
temperature of 150 C.
Note 2. Cat No. BA-2RV22-A2 was investigated for a special application requiring 100,000 operations, for a rating of 600 V ac, 1.2 A steady state, 8.9 A in rush. The switch
is not under follow-up for this rating or number of cycles. Cat No. BA-2R273-A2 was investigated for a A600 and R300 rating. Tests were conducted in accordance with the
Standard for Industrial Control Equipment (UL 508). No follow up tests are being conducted for this rating.
B, D, L, M, N, P, Q, R, T, V
or L208
R, S, T, V or X, ww/o
f/b A, B or S, f/b L, P,
R or W,f/b 1 thru 4
+When these switches are followed by suffix "TP", they should not exceed a temperature of 85 C, and if they are marked with letter "T" in a circle, they should not exceed a
temperature of 150 C. Those marked with the letter "H" in a circle, they should not exceed a temperature of 180 C.
@85 Deg. C except: 150 Deg. C. when "A" is in numbering system field 5.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 28 of 51
-1R, ww/o D, L, M, N, Q, S, T
A, B, D, L, M, N, Q, S, T, V
+ Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively. BM-1RD-D160
should not exceed 90 C.
# Representative of Cat No. BM-1R Series was initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
L, M, N, P, Q, R, S, W, X or a
+ Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively. BM-1RD-D160
should not exceed 90 C.
L, M, N, Q, R, S, T, W or X, or
letter A, B, D, K, P, PC, PP or
L96, or L233.
+. Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
D, L, M, N, Q, S, T, W or X, or
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 29 of 51
letter A, B, D, K, P, PC, PP or
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
f/b D, L, M, N, Q, R, S, T or
W, or a combination of these
hyphenated letter A, B, D, K,
P, PC or PP, or T without a
+. Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
D, L, M, N, Q, R, S, T, W or
X, or a combination of these
hyphenated letter A, B, D, K,
P, PC, PP or T, or TC without
hyphen)
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
L95 or L169.
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C, respectively.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 30 of 51
S, T, W or X, or a combination of these
A, B, D, K, P, PC, PP or T, or TC without a
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C, respectively.
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C, respectively.
or -2G ww/o, D, L, M, N, Q, S, T or W, or
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C, respectively.
f/b L4
f/b L169
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C, respectively.
f/b D, K, L, M, N, Q, S, T,
W or X or a combination of
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 31 of 51
D, K, P, PC, PP or T or TC
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
f/b D, L, M, N, Q, S, T,
or W, or a combination of
D, K, P, PC, PP or T,
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
f/b D, L, M, N, Q, R, S, T,
W or X, or a combination of
D, K, P, PC or PP or T,
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
D, E, L, M, N, Q, R, S, T See
or W, or a combination of Note 3
D, K, P, PC, or T, or TC
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
Note 3 - The switch Cat. No. BZ-R1433-A22 rated L111 was tested in a raised ambient of 250 F. The endurance test was conducted for 100,000 C, for a rating of 15 A, 240
V ac, resistive. The tests were conducted in accordance with our Standard for Temperature Indicating and Regulating Equipment (UL 873) Ninth Editions.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 32 of 51
N, Q, S, T or W, or a See Note 4
L180
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
Note 4. Shorting bar construction switches (-2A & -3A) are not intended for connection in the circuits where a condition of opposite polarity may exist between opposite
sides of the contact structure. These switches must be mounted on insulating material or with a suitable insulating barrier supplied between the switch terminals and the
mounting surface when it is metal.
Q, R, S, T or W, or a
letter A, B, D, K, P, PC or
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
N, Q, R, S, T or W, or a with suffix
letter A, B, D, K, P, PC or
L87
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
T or W, or a combination of
K, P, PC or PP, or T without a
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 33 of 51
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
M, N, Q, R, S, T, W or X, or a -PC2)
letter A, B, D, K, P, PC or
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
N, Q, S, T or V, ww/o numerals,
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
L, Q, N, S or V, ww/o numerals,
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
L, M, N, P or W, f/b 2 or 3, f/b
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 34 of 51
f/b L222
Note 5-The Cat No. MML21KK2BBKRSDR-001 may be provided with leads and a receptacle. The suitability of the leads and receptacle must be determined in accordance
with the end-use product standard.
f/b F, G, H, K, M, P, R or W,
L243
F, H, K, P, R or W, ww/o NC,
NY or XX, ww/o A, B or X,
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 35 of 51
L223
2 or 3
OPD, Types AL, ALM, AR, ARH, CL, CLH, 150+ 2/1 or 2 — 6K —
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
designation H, S or T, ww/o
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
V3- or V3L- f/b 1 thru 99, 201 90@ 1/1 or 2 — 6K(12K See Note 6
V3- or V3L- f/b 101 thru 199, 301 90@ 1/1 or 2 — 6K(12K See Note 6
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 36 of 51
L206 or L291
V3- or V3L- f/b 101E thru 199E or 90@ 1/1 or 2 — 6K(12K for See Note 6
L112
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 130 C or 150 C respectively.
+Certain switches were initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
Note 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is required.
V3- or V3L- f/b 601E thru 699E#, 90@ 1/1 or 2 — 6K(12K See Note 6
125Vac "L")
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 130 C or 150 C respectively.
+Certain switches were initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
Note 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is required.
V3- or V3L-, f/b 1101 thru 1199, 90@ 1/1 or 2 — 6K(12Kfor all See Note 6
V3- or V3L-, f/b 1101E thru 1199E, 90@ 1/1 or 2 — 6K(12K for 125V See Note 6
V3- or V3L-, f/b 1901 thru 1999#, 90@ 1/1 or 2 — 6K(12K for all See Note 6
@ - All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 130 C or 150 C respectively.
+ - Certain switches were initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
Note 6 - When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is
required.
-L186 or V3L-1949-L186.
V3-, f/b 1981 or 1983, f/b -D8, f/b 130 1/1 or 2 — 6K(12K for 125Vac See Note 6
V3- or V3L-, f/b 2101 thru 2199 or 90@ 1/1 or 2 — 6K(12K for 125Vac"L"), See Note 6
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 37 of 51
@ - All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 130 C or 150 C respectively.
+ - Certain switches were initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
Note 6 - When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is
required.
V3-or V3L- f/b 2401 thru 2599#, 90@ 1/1 — 6K See Note 6
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 180 C or 150 C, respectively.
Note 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is required.
V3- or V3L- f/b 3001 thru 90@; 1/1 — 6K(12K See Note 6
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 180 C or 150 C, respectively.
+Certain switches were initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
$Cat. Nos. V3L-f/b 3235, 3236 or 3238, f/b -D8 are follow-up tested at 100,000 cycles with ratings of 3A, 125/250 Vac.
Note 6 — When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is
required.
V3- or V3L- f/b 3001E thru 3099E#, 90@ 1/1 or 2 — 6K(12K See Note 6
Vac "L")
V3- or V3L- f/b 4001 thru 4099#, 90@ 1/1 or 2 — 6K(12K See Note 6
Vac "L")
(100K)+
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 180 C or 150 C respectively.
+Certain switches were initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
Note: 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is
required.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 38 of 51
V3- or V3L- f/b 4501 thru 4599#, 90@ 1/1 — 6K(100K)+ See Note 6
f/b L226 or 2
V3- or V3L- f/b 41001 thru 41999#, 90@ 1/1 — 6K See Note 6
f/b L232 or 2
V3- or V3L- f/b 70001 thru 74999#, 90@ 1/1 — 6K(100K)+ See Note 6
or 2
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 180 C or 150 C respectively.
+Certain switches were initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
Note: 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is
required.
V4-61-L4L4 55 1/2 — 6K —
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 180 C or 150 C respectively.
Note: 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is
required.
7, 8, 9 or A, f/b D8, D9 , 7,
(100K)++
(100K)++
@-85 Deg. C except: 150 Deg. C when "A" is in numbering system digit 5.
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 39 of 51
f/b L292
@-85 Deg. C except: 150 Deg. C when "A" is in numbering system digit 5.
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
(100K)++
f/b L239
@85 Deg. C except: 150 Deg. C when "A" is in numbering system digit 5.
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
2 or 3, f/b 0 thru 4, 7, 8,
f/b L264
f/b L278
@85 Deg. C except: 150 Deg. C. when "A" is in numbering system field 5.
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 40 of 51
L242 or L258
B, D, L, N, P, Q, or 2 (12K for
numbers ww/o A, B, D,
+Cat. No. V10, f/b 1 thru 4, f/b E, with code L242 was initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
++When these switches are followed by suffix "TP", they should not exceed a temperature of 85 C, and if they are marked with letter "T" in a circle, they should not exceed
a temperature of 150 C.
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
Note 8-These switches are provided with a metal actuator with or without an actuator cover. The metal actuator is an uninsulated live part (one piece construction of
terminal, contact and actuator arm). When the cover is not provided, consideration should be given to the means of actuation and control with an uninsulated live part which
would normally be assumed to be a dead metal (grounded) part.
WA-1Rx123-A4-L22 82 1/1 or 2 — 6K —
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
D, L, M, N, Q, R, S, T -PC2)
or W, or a combination of
letter A, B, D, K, P,
PC or PP, or T without
WZ-Refer to BZ Series — — — — —
for details
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
YZ(Refer to BZ Series — — — — —
for details
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 41 of 51
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
+Representative samples of DM Type of switches rated L226, L229 and L230 were tested initially at 100,000 cycles. Follow-Up tested at 6000 cycles. For specific catalog
numbers, see the test records of the Report.
f/b L305
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 42 of 51
+Where the neoprene or fiber liner is depended upon for insulation, the max temperature on the materials should not exceed 60 C and 90 C respectively.
+. Cat. Nos. PL1 thru PL1000 and PL6700 thru PL6799 were initially tested at 100,000 Cycles and 30,000 Cycles respectively. Follow-Up tested at 6000 Cycles.
Note 9. Terminals designated by Suffix "H58" have been investigated for use with receptacles AMP, No. 61160-1, and the use with other terminals should be investigated in
the end-use product.
ww/o suffix of up to 5
f/b L191
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
ww/o suffix of up to 5
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 43 of 51
f/b L192
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
of up to 5 letters and/or
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
+Cat. No. 13AC9 was initially tested at 100,000 cycles. Follow-Up tested at 6000 cycles.
++Where the neoprene or fiber liner is depended upon for insulation, the maximum temperature on the materials should not exceed 60 C and 90 C respectively.
Note 11-These switches may employ a varnished impregnated fiberglass shield which has been subjected to Dielectric Strength Tests. For further details see Report.
f/b L25
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 44 of 51
2VP f/b 7000 thru 7999#, f/b L109 90@ 2/1 or 2 PP 6K See Note 6
@All switches marked with letter "H" or "T" in a circle above the rating should not exceed the temperature of 130 C or 150 C respectively.
Note 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is required.
3A, 3B, 3E, 3F, 3G, 3H, 3K or 3L, 55 1 or 2/1 or 2 PP 6K 2, See Note 12
f/b L22
Note 12. The switches may be "matrix" mounted. A glass filled polycarbonate is used for the connector. See Report (Test Record No. 1) for results of a temperature test
conducted. The use of the " matrix" mounting should be considered in the final application.
Note 9. Terminals designated by Suffix "H58" have been investigated for use with receptacles AMP, No. 61160-1, and the use with other terminals should be investigated in
the end-use product.
G, R, S, W or Y, f/b J, K, L,
or L171.
numbers, f/b L4
L151
numbers, f/b L7
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 45 of 51
Note 7. The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
Note 11. These switches may employ a varnished impregnated fiberglass shield which has been subjected to Dielectric Strength Tests. For further details see Report.
+Where the neoprene or fiber liner is depended upon for insulation, the maximum temperature on the materials should not exceed 60 C and 90 C respectively.
L111
+Where the neoprene or fiber liner is depended upon for insulation, the maximum temperature on the materials should not exceed 60 C and 90 C respectively.
f/b L86
+Where the neoprene or fiber liner is depended upon for insulation, the maximum temperature on the materials should not exceed 60 C and 90 C respectively.
++Switches marked with letter "T" in a circle above the rating should not exceed 150 C.
Note 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is required.
L115
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 46 of 51
8AC29-UL 65 2/2 PP 6K 11
+Cat. Nos. PL1 thru PL1000, PL6700 thru PL6799 were initially tested at 100,000 Cycles and 30,000 Cycles respectively. Follow-Up tested at 6000 Cycles.
Note 7-The case, actuator and plunger seals have not been evaluated for their sealing ability and should not be considered reliable for protection against contamination.
Note 11-These switches may employ a varnished impregnated fiberglass shield which has been subjected to Dielectric Strength Tests. For further details see Report.
f/b L128
+Where the neoprene or fiber liner is depended upon for insulation, the maximum temperature on the materials should not exceed 60 C and 90 C respectively.
Note 9-Terminals designated by Suffix "H58" have been investigated for use with receptacles AMP, No. 61160-1, and the use with other terminals should be investigated in
the end-use product.
311SX or 333SX
f/b L4 or L122
+. Cat. Nos. PL1 thru PL1000, PL6700 thru PL6799 were initially tested at 100,000 Cycles and 30,000 Cycles respectively. Follow-Up tested at 6000 Cycles.
++. Where the neoprene or fiber liner is depended upon for insulation, the maximum temperature on the materials should not exceed 60 C and 90 C respectively.
Note 13. These switches are equipped with an adjusting wheel which varies the contact air gap from a minimum of 0.006 in. to a maximum or 0.070 in. The adjusting wheel
is of melamine material.
Note 9. Terminals designated by Suffix "H58" have been investigated for use with receptacles AMP, No. 61160-1 and the use with other terminals should be investigated in
the end-use product.
11TS f/b 1, 11, 15, 85, 85 1/2 — 6K(12K for 5A, See Note 14
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 47 of 51
f/b L192
11TS f/b 15, 95 or 115, f/b number 1 thru 8, f/b L311 65 1/1,2 - 6K -
f/b L111
Note 13. These switches are equipped with an adjusting wheel which varies the contact air gap from a minimum or 0.006 in. to a maximum of 0.070 in. The adjusting wheel
is of melamine material.
Note 14. These switches may employ an external nylon or PVC sleeve over the actuating lever which have not been investigated for temperatures above 55C. These
switches may also employ rubber seals which have not been investigated for resistance to contamination or temperatures above 55C.
12TS f/b 15, 95 or 115, f/b number 1 thru 8, f/b L312 65 1/1,2 - 6K -
Note 14-These switches may employ an external nylon or PVC sleeve over the actuating lever which have not been investigated for temperatures above 55C. These switches
may also employ rubber seals which have not been investigated for resistance to contamination or temperatures above 55C.
or L23 or 2
L163 or L195
Note 11-These switches may employ a varnished impregnated fiberglass shield which has been subjected to Dielectric Strength Tests. For further details see Report.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 48 of 51
+Cat. No. 41SM1-T-L212 was initially tested for 30,000 cycles. Follow-Up tested for 6000 cycles.
Note 9-Terminals designated by Suffix "H58" have been investigated for use with receptacles AMP, No. 61160-1, and the use with other terminals should be investigated in
the end-use product.
with L25
+Representative Samples of DM Type of switches rated L226, L229, and L230 were tested initially at 100,000 cycles. Follow-Up tested at 6000 cycles. For specific catalog
numbers, see the records of the Report.
f/b L62
211TS or 511TS f/b 1, 11, 15, 85, 85 1/2 — 6K(12K for5A, See Note 14
f/b L191
+Cat. Nos. PL1 thru PL1000 and PL6700 thru PL6799 were initially tested at 100,000 Cycles and 30,000 Cycles respectively. Follow-Up tested at 6000 Cycles.
Note 14-These switches may employ an external nylon or PVC sleeve over the actuating lever which have not been investigated for temperatures above 55C. These switches
may also employ rubber seals which have not been investigated for resistance to contamination or temperatures above 55C.
311TS or 312TS f/b 1, 11, 15, 85, 85 1 or 2/2 PP 6K(12K See Note 14
311TS or 312TS f/b 1, 11, 15, 85, 85 1 or 2/2 PP 6K(12K See Note 14
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 49 of 51
f/b L191
Note 14-These switches may employ an external nylon or PVC sleeve over the actuating lever which have not been investigated for temperatures above 55C. These switches
may also employ rubber seals which have not been investigated for resistance to contamination or temperatures above 55C.
L235 or L236
Note 11-These switches may employ a varnished impregnated fiberglass shield which has been subjected to Dielectric Strength Tests. For further details see Report.
+Representative Samples of DM Type of switches rated L226, L229, and L230 were tested initially at 100,000 cycles. Follow-Up tested at 6000 cycles. For specific catalog
numbers, see the test records of the Report.
(12K for
125Vac,"L")
+Representative Samples of DM Type of switches rated L226, L229, and L230 were tested initially at 100,000 cycles. Follow-Up tested at 6000 cycles. For specific catalog
numbers, see the test records of the Report.
@All switches marked with letters "H" or "T" in a circle above the rating should not exceed the temperature of 130 C or 150 C respectively.
Note 6-When used with an external tooth lock washer, a 3/64 in. spacing to the normal mounting surface of the switch is not provided and an acceptable barrier is required.
UX30 f/b C — 6K —
Note 3: These switches have been investigated for use only in an ordinary environment. Switches should be evaluated for compliance with the end use product standard if
intended to be used in environment such as oil, freon, X-Ray, etc.
UM35C, D, E 65 1P/1 or 2T — 6K —
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 50 of 51
Note 3: These switches have been investigated for use only in an ordinary environment. Switches should be evaluated for compliance with the end use product standard if
intended to be used in environment such as oil, freon, X-Ray, etc.
6K, 100K —
100K —
100K —
100K —
f/b A, B, C, D, F, H or S,
f/b D or W, f/b 1, 3 or 4,
f/b -10,-50,-60;
f/b -90
Note 3: These switches have been investigated for use only in an ordinary environment. Switches should be evaluated for compliance with the end use product standard if
intended to be used in environment such as oil, freon, X-Ray, etc.
Note 9: Switch was tested w/wire size 16 AWG connected to Quick Connect Tab size #110.
Note 15: Cat. Nos. 311SM2-T and 311SM6-T were additionally tested with Overload Test parameters of 22 A, 26.4 V ac, 50 Cycles with a Power Factor of 65-75%.
Endurance Test parameters were 4 A, 24 V ac, 55,000 Cycles with a Power Factor of 98-100%. Refer to Test Record 32 of Report dated 2/25/1952 for further details.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
WOYR2.E12252 - Switches, Special Use - Component Page 51 of 51
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service.
Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or
Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from
the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "Copyright © 2006 Underwriters Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=WOYR2.E12252&ccnshorttitle=... 3/30/2006
UIRV.E19310 - Heat-automatic Fire Detectors for Use in Hazardous Locations Page 1 of 2
UIRV.E19310
Heat-automatic Fire Detectors for Use in Hazardous Locations
Page Bottom
See General Information for Heat-automatic Fire Detectors for Use in Hazardous Locations
-013
Electrical ratings: 5 amp, 125 v, ac; 0.5 amp, 125 v, dc; 2.0 amp, 24 v, dc; 1.0 amp, 48 v, dc.
This Listing applies to heat detectors only and not to wiring or other appliances of systems of which they form a part.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's
Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for
the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,
Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2008 Underwriters
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=UIRV.E19310&ccn... 4/1/2008
UIRV.E19310 - Heat-automatic Fire Detectors for Use in Hazardous Locations Page 2 of 2
Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=UIRV.E19310&ccn... 4/1/2008
QVAJ7.E199827 - Process Control Equipment for Use in Class I, Zone 0, 1 and 2 Hazardous Locations C... Page 1 of 2
-.+/0 112 0
! / :
!
! "#$#%&'( "#$#%&') "#$$#%##) "#$#%##" * +
# $ $ % * / 0 1 &- & &- & 2 2 &- - &- - &- " &- 3( &- 3( 2 2 &- 4 & &-
4 & &5 &- 4 & 2 2 &- 4 - &- 4 - &- 4 " &- 4 " 2 2 &- 4 3( &- , 2 &- , 2. &- , 2. &- 6 &- 6. 5 &.
5 &. 54 3. 54 3.7. 54. 2 &7 & &-/8. &- 79 5 &- 6 &- / &- 6. &- , 2.
&-.
&#$ 4 3, 54 &. 7./ 54 &.7.
/ 54 &. 54 &. & / 42 42 7 &-/8 .
7 &-/8 7/ ##& 3&" ##& &%(:
0 0 5
0 3 % 7 3$ %$ 7 : 0 0 , 0 : 0 0 2
3$$ 3$$
* , 2 0 1 % 9 " 9 - 9. 9 ? @ ) 9. 9 ? @ ( 9.
& 9? @ - 9. 9 ? @ ) 9. 9 ? @
( 9.& 9? @
* , 2 0 1 "6 )6 . 9 (6 .
& 9 (6 .
& 9 (6 .
& 9 &$ : 0 0 ,3$ ,33
+ , 2 7 2 7
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QVAJ7.E199827... 1/29/2008
QVAJ7.E199827 - Process Control Equipment for Use in Class I, Zone 0, 1 and 2 Hazardous Locations C... Page 2 of 2
+
# $ $ % * / 0 5 & 5 : 0 0 5
* ) * 2./ &-/8 2
7* &$$" $3 $"
K1 L 2 : ! *
* ! D &$$"7 0 E
** :* F : * 1 0 1 * 1 + 0 : 1 1 1 7F
7* + 4 * 1 0 ! 7 G 1 0 0 + 1 7F 7* + 5 G
G * 1
7 * : * 1 : 4 10H ! I3 61 :
! . ! ? @:1 0 * : !: 1 : *1 ? !@
& : J * : 4 * : :7 0 J :1 ** H
: * : :1 1 * ! ! : IJ * ! D &$$"7
0 EJ
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QVAJ7.E199827... 1/29/2008
QQPX2.E211190 - Power Supplies for Use in Hazardous Locations - Component Page 1 of 1
QQPX2.E211190
Power Supplies for Use in Hazardous Locations - Component
Page Bottom
See General Information for Power Supplies for Use in Hazardous Locations - Component
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's
Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for
the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,
Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2007 Underwriters
Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QQPX2.E211190... 12/6/2007
PTDR.E6951 - Motors for Use in Hazardous Locations Page 1 of 1
PTDR.E6951
Motors for Use in Hazardous Locations
Page Bottom
Class I, Group D; Class II, Groups E, F, and Gmotors with Listed brakes. The brakes in these explosion-proof and dust ignition proof assemblies are
intended essentially for holding purposes and may be used for stopping light inertia loads.
Class I, Group D; Class II, Groups F and Gmotors for use with pulse width modulated variable frequency inverter drives over the frequency range
of 6 to 90 HZ .
Class I, Group Dmotors for use with voltage source, current source and pulse width modulated variable frequency inverter drives over the frequency
range of 0 to 120 HZ .
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under
UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always
look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,
Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2007 Underwriters
Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=PTDR.E6951&... 11/15/2007
NWHP2.E224022 - Information Technology Equipment for Use in Hazardous Locations - Comp... Page 1 of 1
)* +"( "",-""
0 %
! = 8 8 , " BC # 7 -5 ' #
. /* $ 0$ )1 $ ) %.$ 2 B D)
) ! (1 !,
8E 7+BB E8 . )D7!
# !! " #"
$ ! %&
! " # $ % (
F G ( 1 0 ,#
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NWHP2.E... 3/6/2006
NWGQ8.E136709 - Information Technology Equipment Including Electrical Business Eq... Page 1 of 2
*+ ,-./ 012345
,9 @
@A
( 4& ,<47&
A,@
'47&<
47&
A,@
'4- 6=4 92 BC'
DA 4@<
46C '
49 6@
&'6, C '
4 BC'
DA 4@ &
@'7
' 7& ,4, ,
AD 4 4@
6 $+ ) %) *7 ) * 6) 8 E)
1 -
<
; % < E 0
*********
# *****+++ ,
# - .
$ % % %
# ,5 / 6/ 8 6 6
# ! " " % % %
% % % %
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=N... 3/6/2006
NWGQ8.E136709 - Information Technology Equipment Including Electrical Business Eq... Page 2 of 2
5 := & : 6,45 & E>,6,45 & >56,45 * % &5,4?>66,45 " &5,4?> 6,45 &5,4?>
76,45
@ 3>96,45 @3
F F 6,45 E" ">F,F 6,45 & - & 1 & >F5F 6,45 & >F6F 6,45 * & % & &5,4?>F2F 6,45
" &5,4?>F F 6,45 &5,4?>F F 6,45 5,4?>F7
F 6,45 3>F9F 6,45 3
. : 52 ,D=,6=,&
,6@&
,&
?'49G AD,424,A &@
&, 4,A F E) F F D& 6= &
. 6=C=F A '
94,@
'4,4 / 6 94'
H AD 4 4@ ,&
?7&
,4, ,
;, @ D ,@ 4 0
NC @
'4 O 1@
'6 7 '6,'
A & ,9 - D
D2&
'9=@I 4 &
:&'
@& ;,5 &
,@&
' <
46J
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=N... 3/6/2006
NWFN8.E182378 - Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations Certified for Canada - Component Page 1 of
UL Online Certifications Directory
NWFN8.E182378
Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations Certified for Canada - Component
Page Bottom
Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations Certified for Canada - Component
See General Information for Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations Certified for Canada - Component
Voltage limiters, for use with Listed or Recognized pilot lights, Type 80 100 01 74 0.
Marking: Company name, type designation and Recognized Component Mark for Canada .
Last Updated on 2006-05-11
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products
bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be
presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format:
"Copyright © 2006 Underwriters Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NWFN8.E182378&ccnshorttitle=Auxiliary+Dev... 10/19/2006
NWFN2.E182378 - Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations - Component Page 1 of
UL Online Certifications Directory
NWFN2.E182378
Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations - Component
Page Bottom
Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations - Component
See General Information for Auxiliary Devices for Use in Class I, Zone 0, 1 and 2 Hazardous Locations - Component
Voltage limiter, for use with Listed or Recognized pilot lights, Type 80 100 01 74 0.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products
bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be
presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format:
"Copyright © 2006 Underwriters Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NWFN2.E182378&ccnshorttitle=Auxiliary+Dev... 10/19/2006
NRAG.E198348 - Programmable Controllers for Use in Hazardous Locations Page 1 of 1
NRAG.E198348
Programmable Controllers for Use in Hazardous Locations
Page Bottom
See General Information for Programmable Controllers for Use in Hazardous Locations
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's
Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for
the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,
Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2008 Underwriters
Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NRAG.E198348&... 2/18/2008
NRAG7.E183151 - Programmable Controllers for Use in Hazardous Locations Certified for Canada Page 1 of 2
NRAG7.E183151
Programmable Controllers for Use in Hazardous Locations Certified for Canada
Page Bottom
See General Information for Programmable Controllers for Use in Hazardous Locations Certified for Canada
I/O communication modules, Models 1560-MBP, 1560-PDP, 3170-INTB, -INTB-4 , 3170-MBS, 3300-MBP, 3350-MBP, 3700-DEM, 3750-DEM.
Models 4101, 4102, 4104, 4105, 4106, 4107, 4127, 4201, 4202, 4204, 4205, 4206, 4207, 4210, 4301, 4302, 4303, 4304, 4305, 4306, 4307, 4310,
4502, 4506, 4507, 4601, 4602, 4604, 4605, 4606 or 4607 may be followed by additional characters.
Models 5101, 5102, 5104, 5105, 5106, 5107, 5127, 5201, 5202, 5204, 5205, 5206, 5207, 5210, 5301, 5302, 5303, 5304, 5305, 5306, 5307, 5310,
5502, 5506, 5507, 5601, 5602, 5604, 5605, 5606 or 5607.
Models 6101-WA, 6102-WA, 6104-WA, 6105-WA, 6106-WA, 6107-WA, 6127-WA, 6201-WA, 6202-WA, 6204-WA, 6205-WA, 6206-WA, 6207-WA, 6210-
WA, 6301-WA, 6302-WA, 6303-WA, 6304-WA, 6305-WA, 6306-WA, 6307-WA, 6310-WA, 6502-WA, 6506-WA, 6507-WA, 6601-WA, 6602-WA, 6604-WA,
6605-WA, 6606-WA and 6607-WA.
Logic units, Models 3100-CAS, 3100-CBM, 3100-DFM, 3100-EMC, 3100-FOX, 3100-GDF, 3100-GSI, 3100-HAR, 3100-IMP, 3100-LNG, 3100-LTQ, 3100-
MCM, 3100-MDA16, 3100-MDA4, 3100-MDA-USA, 3100-MTS, 3100-N2, 3100-PCX, 3100-ROC, 3100-SEA, 3100-SYS, 3100-YRK.
Programmable controllers, 7000-xxx, 7100-xxx, 7005-xxx, 7105-xxx, 7008-xxx, 7108-xxx, 7009-xxx, 7109-xxx, 7010-xxx, 7110-xxx, 7015-xxx,
7115-xxx, 7108-xxx, 7118-xxx, 7109-xxx, 7119-xxx.
Serial communication modules, Models MVI46-XXX, MVI56-XXX, MVI56-MBP, MVI71-XXX, MVI94-XXX, where XXX may be additional suffixes.
Models MVI56-XXXNET, MVI56-AFC, MVI56-DEM, MVI56-MBP, MVI56-PDPS, where XXX may be additional suffixes.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's
Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for
the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NRAG7.E183151... 2/25/2008
NRAG7.E183151 - Programmable Controllers for Use in Hazardous Locations Certified for Canada Page 2 of 2
Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2008 Underwriters
Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NRAG7.E183151... 2/25/2008
NITW8.E183955 - Industrial Control Panels Certified for Canada - Component Page 1 of 1
NITW8.E183955
Industrial Control Panels Certified for Canada - Component
Page Bottom
See General Information for Industrial Control Panels Certified for Canada - Component
Interface connectors for use in industrial control panels.Series BN, CX, DA, DB, DDB, DH, DM, DN, DP, DP1, EP, GF, RJ followed by additional
letters and/or numbers.
Marking: Company name, series designation and the Recognized Component Mark for Canada .
Last Updated on 2001-10-01
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's
Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for
the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,
Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2007 Underwriters
Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NITW8.E183955... 12/6/2007
File 032169-007, Class 6225-01 Page 1 of 1
Certification Record
l Fuseholder assemblies, segmented fuse blocks type for use with standard code cartridge fuses,
stack type blocks or 1-, 2- or 3-pole, 250V max, Cat Nos 1491-N122, 1491-R162, 600V, 1491-
N161, 30A.
l Cat Nos 1492-FB1C30, -FB2C30; FB3C30, -FB1C30-L, -FB2C30-L, -FB3C30-L, 30A max,
600V ac max, DIN rail mounting - NOT FOR DISCONNECT means - NOT FOR BRANCH
CIRCUIT protection/wiring.
l Fuseholder, segmented type blocks, for use with 1-1/2 in by 13/32 in dia cartridge fuses, single or
multi-pole, Class M. Part Nos 1491-R165, -R167, -R169, -R171, 30A max, 600V max.
l Cat Nos 1492-FB1M30; -L; -D1; -D2; 1492-FB2M30; -L; 1492-FB3M30; -L, 30A max, 600V ac
max, 90V dc max for miscellaneous and Class CC fuses respectively, DIN rail mounting - NOT
FOR DISCONNECT means.
l Fuseholder, extractor type; Cat Nos 1492-FB1J30; -L; -FB2J30; -L; -FB3J30; -L; 30A, 600V ac,
1492-FB1J60; -L; -FB2J60; -L; -FB3J60; -L, 60A, 600V ac.
Notes:
1. All fuseholders have pressure type (box) wire connector type terminals only, except for the 30A
fuseholders which may have terminals either of the wire binding screw type sems type, or the box
type (pressure connector).
2. All fuseholders are certified only as component parts of larger certified assemblies where the
suitability of the combination has been determined by the Canadian Standards Association.
/sp
http://directories.csa-international.org/xml_transform.asp?xml=certxml\6162-6225-01.xm... 12/11/2003
Page 1 of 1
Certification Record
Class I Division 2 Group D; Class I Zone 2 IIA; T3 Gas, Liquid, or Dual Fuel Turbine Driven Generator
Sets Models:
l "SATURN" 1.2 MW max, 6.6 KV max, 3 phase, 50 or 60 Hz; Control Circuit 24 V dc, 15 A max.
l "CENTAUR" 4.6 MW max, 13.8 KV max, 3 phase 50 or 60 Hz; Control Circuit 24 V dc, 15 A
max.
l "TAURUS 60" 5.2 MW max, 13.8 KV max, 3 phase, 50 or 60 Hz; Control Circuits 24 V dc, 15 A
max.
l "TAURUS 70" 6.9 MW max, 13.8 KV max, 3 phase, 50 or 60 Hz; Control Circuits 24 V dc, 15 A
max.
l "MARS" 10.7 MW max, 13.8 KV max, 3 phase, 50 or 60 Hz; Control Circuit 24 V dc, 15 A max.
l "TITAN 130", 12.8MW max, 3 phase, 13.8 KVmax, 50 or 60 Hz, Control Circuits 24 Vdc,
15Amax.
Notes:
dt
http://directories.csa-international.org/xml_transform.asp?xml=certxml\4454-4215-01.xml&xsl=xsl/certrec.xsl
... 11/1/2002
Page 1 of 1
Certification Record
dt
http://directories.csa-international.org/xml_transform.asp?xml=certxml\4454-9098-01.xml&xsl=xsl/certrec.xsl
... 11/1/2002
Page 1 of 1
Certification Record
l Turbine Control Consoles, 120 V ac, 20 A max or 24 V dc, 100 a max, may have Intrinsically
Safe output circuits per wiring diagram, free standing, or wall mounting.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\4454-3211-07.xml&xsl=xsl/certrec.xsl
... 11/1/2002
Page 1 of 1
Certification Record
l "SATURN" 1.2 MW max, 6.6 KV max, 3 phase, 50 or 60 Hz; Control Circuit 24 V dc, 15 A max.
l "CENTAUR" 4.6 MW max, 13.8 KV max, 3 phase 50 or 60 Hz; Control Circuit 24 V dc, 15 A
max.
l "TAURUS 60" 5.2 MW max, 13.8 KV max, 3 phase, 50 or 60 Hz; Control Circuits 24 V dc, 15 A
max.
l "TAURUS 70" 6.9 MW max, 13.8 KV max, 3 phase, 50 or 60 Hz; Control Circuits 24 V dc, 15 A
max.
l "MARS" 10.7 MW max, 13.8 KV max, 3 phase, 50 or 60 Hz; Control Circuit 24 V dc, 15 A max.
l "TITAN 130", 12.8MW max, 3 phase, 13.8 KVmax, 50 or 60 Hz, Control Circuits 24 Vdc,
15Amax.
Notes:
dt
http://directories.csa-international.org/xml_transform.asp?xml=certxml\4454-4218-01.xml&xsl=xsl/certrec.xsl
... 11/1/2002
Page 1 of 2
Certification Record
l Horns, resonating type, for outdoor use; Model 55, 110/120V, 60Hz, 0.75A and 250V, 60Hz,
0.3A.
l Horns vibrating type, Models 350, 6V, 1.9A; 12V, 0.9A, 12V, 1.8A; 24V, 0.9A;120V, 0.18A;
240V, 0.09A ac input. Model 350D, ac polarized, 120V, 0.16A.Models 450, dc, 4.4 - 9V, 0.25A;
6V, 1A; 9-15.6V, 0.125A; 12V, 0.5A; 18-31.2V,0.063 or 0.035A; 24V, .25A; 48V, 0.125A;
125V, 0.05A; 250V, 0.025A; 300V,.030A, dc input. Model 450D dc polarized horns, 4.4-9V,
.25A; 9-15.6V, 0.125A; 18-31.2V, 0.063 or 0.035A; 48V, 0.125A.
Note: Suffix letters CC, FB, NB, SF, PR, PR2, FBL or FG are used to indicate thy type of mounting
accessories. The suffix letter WB indicates a weatherproof back box for outdoor use.
l Bells, 4, 6, 10 in size, vibrating type, Models 500, 240V and less, 50/60Hz, 1.6A and less; 600,
250V dc and less,1.6A and less; single-stroke type, Models 700, 240V and less, 50/60Hz, 3.2A
and less; 800, 250V dc and less, 1.6A and less, with or without suffix letters CC, FB, FBL, FG,
NB, NBL or SF for indoor use and WB (back box) for outdoor use.
l Sirens, motor-driven, for outdoor use; Type A, 120V ac/dc, 1.25A; Type L, 120/125V ac/dc,
1.95A or 240/250V ac/dc, 1.0A; Type No 2, 220V, 60Hz, 12A, 2 hp, single-phase intermittent
duty; Type No 5, 220V, 60Hz, 60A, single-phase, 220V, 60Hz, 35A polyphase, 230V dc, 45A and
250V dc, 41A, 5 hp; "Thunderbolt" Models 1000* and 1003*, 220/440V or 550V, or 600V
(different models), 60Hz, 34/17A, or 14A, or 12A total respectively, 3-phase ac input; blower
motor, 7 hp; rotator motor, 1/3 hp; chopper motor, 2 hp.
l * Time rating 10 min "on"; 50 min "off".
l Siren control panel for indoor use; Model RCM-1 for use with siren, Model 1000 or 1003.
l Auxiliary tone-modulating control panel for indoor use; Model RCM-2 for use with siren, Model
1003 and control panel RCM-1 above.
l Amplified speakers/audible signals, for indoor or outdoor use,(Enclosure 3R): Model ASHP, 24V
dc, 0.55A or 120V, 50/60Hz, 0.28A; Model ASLP, 24V dc, 0.07A; Models 50GC and 50GCB,
24V, 50/60Hz, 0.22A or 24V dc, 0.07A or 120V, 50/60Hz, 0.033A or 230/240V, 50/60Hz, 0.02A;
Model 300D, 24V dc, 0.6A or 120V, 60Hz, 0.28A; Model 300GC, 24V, 50/60Hz, 1.25A or 24V
dc, 0.55A or 48V dc, 0.35A or 120V, 50/60Hz, 0.27A or 240V, 50/60Hz, 0.12A; Model 302GC,
24V, 2.5A or 24V dc, 1.1A or 120V, 50/60Hz, 0.5A or 240V, 50/60Hz, 0.2A; Model 300, 250V
dc, 0.072A.
l Plug-in modules, Models TM-1 through -11, -11A, -12, -13, -33; TC-BL, -BP, -HL, -HN, -ST, -
SW, -TW, -YP, -WL, -YW, UTM, PTCK25, PTCK70, AM25CK, AM70CK, 300CK, 300CKS,
for use with the above amplified speakers.
l Intercoms, Models 310-MV, (Type 4X), 310LD-MV, 310-MV-MNC, 24V dc or 120/240V,
50/60Hz, 0.26A max; microphone conversion kit K850A016 and slave conversion kit K850A017.
l Speakers, for indoor or outdoor use, (Enclosure 3R), 25 or 70V ac, Models AM300, SPHP, 0.5,
http://directories.csa-international.org/xml_transform.asp?xml=certxml\520-4812-04.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 2 of 2
1.0, 2.0, 7.0 and 15W power taps; AM302, 7, 15 and 30W power taps; indoor only, Models
AMR4, AMS4, AM50, 0.25, 0.5, 1.0 and 2.0 power taps; AMM1, 25V, 1.0W.
l Signal appliance amplifiers, indoor or outdoor, 120/240V, 50/60Hz, Models 3200, 3.5/1.625A;
3400, 6.5/3.25A.
l Telcom remote ringer devices, Models TELB 120, TELC 120, TELH 120, TELS 120, 120V,
50/60Hz, 0.24A max.
/dlm
http://directories.csa-international.org/xml_transform.asp?xml=certxml\520-4812-04.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Flashing warning lights, outdoor use, Type 3R, Model 141, 120V, 60Hz, 40W; 141ST, 120V,
50/60Hz, 0.045A.
l Strobe lights, indoor/outdoor use, Type 3R, 4X; Models FB2PST, FB24ST and FB2MST, 12/24V
dc, 1.7/0.7A, or 120V, 50/60Hz, 0.25A, or 240V, 50/60Hz, 0.20A; Model 131ST, 120V, 50/60Hz,
0.6A or 240V, 50/60Hz, 0.3A; Models 131DST and 371DST, 12-24V dc, 3.0-1.9A or 120V,
50/60Hz, 0.6A, or 240V, 50/60Hz, 0.3A; VALS, 120/240V, 50/60Hz, 0.060/0.030A; 12/24V dc,
0.180/0.080A.
l Fire alarm control unit Model 300Z, 120V, 50/60Hz, 310mA; trouble and alarm contacts 24V dc,
2A (non-ind).
l Power supply/battery charger, Model PS150, 120/240V, 50/60Hz, 0.45/0.25A input; 24V dc, 1.2A
max output; trouble relay 125V ac, 0.4A, 24V dc, 1.25A.
l Rotating beacon lights, indoor or outdoor, Type 3R, 120V, 60Hz, Models 27S, 0.64A; 27SD,
0.77A; 121S, 0.33A; 225, 0.22A.
l Audio/Visual Signal Appliances, for indoor/outdoor use, Type 3R enclosure, Models AV1,
AV1LED, AV1ST, rated 120V ac, 60Hz, 0.27A, 0.10A, 0.15A; or 24V dc, 0.98A, 0.16A, 0.39A
l Visual Signal Appliance for indoor/outdoor use, Type 4X enclosure, Models LP3 and LP6 strobe,
rated 120V ac, 0.1A, 50/60Hz, 230-240V ac, 0.07A, 50/60Hz; or 12-48V dc, 0.44-0.1A; Model
LP3 (Incandescent) rated 12V dc, 1.04A; 24V dc, 0.67A; 120V ac, 50/60Hz, 0.13A; Model LP3
(LED), rated 24V ac/dc, 50/60Hz, 0.080A; 120V ac, 50/60Hz, 0.045A.
/mek
http://directories.csa-international.org/xml_transform.asp?xml=certxml\520-4812-05.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Bells, 4, 6, 10 in size, vibrating type, Models 500, 240V and less, 50/60Hz, 1.6A and less; 600,
250V dc and less,1.6A and less; single-stroke type, Models 700, 240V and less, 50/60Hz, 3.2A
and less; 800, 250V dc and less, 1.6A and less, with or without suffix letters CC, FB, FBL, FG,
NB, NBL or SF for indoor use and WB (back box) for outdoor use.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\520-4812-84.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Audio/Visual Signal Appliances, for indoor/outdoor use, Type 3R enclosure, Models AV1,
AV1LED, AV1ST, rated 120V ac, 60Hz, 0.27A, 0.10A, 0.15A or 24V dc, 0.98A, 0.16A, 0.39A.
l Visual Signal Appliance for indoor/outdoor use, Type 4X enclosure, Models LP3 and LP6 strobe,
rated 120V ac, 0.1A, 50/60Hz, 230-240V ac, 0.07A, 50/60Hz or 12-48V dc, 0.44-0.1A; Model
LP3 (Incandescent) rated 12V dc, 1.04A, 24V dc, 0.67A; 120V ac, 50/60Hz, 0.13A; Model LP3
(LED), rated 24V ac/dc, 50/60Hz, 0.080A; 120V ac, 50/60Hz, 0.045A.
l Rotating Beacon Lights, indoor/outdoor use, Type 4X, 120V, 50/60Hz, Models 371, 1.75A; 371L,
0.80A.
l Stackable visual or visual and audible signal system. "Litestak", Models LSB and LSBS (base
modules); light modules, Models LSL-024, LSLD-024,
24V dc, 3.8A (with five modules); LSL-120, LSLD-120, 120V ac, 1.13A (with five modules);
LSL-240, 240V ac, 0.6A (with five modules); sound modules, Models LSS-024, 24V dc, 0.170A,
LSS-120, 120V ac, 0.07A; LSH-024, 24V dc, 0.07A; LSH-120, 120V ac, 0.04; LSH-240, 240V
ac, 0.04A.
/mek
http://directories.csa-international.org/xml_transform.asp?xml=certxml\520-4812-85.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
Notes:
1. Suffix letters and numbers may be added to the above series designations to denote mechanical
variations.
2. Supplied only to manufacturers for the assembly of Certified electrical equipment.
l Pilot lights, Series AML41, incandescent; AML42, AML45, LED; AML43, neon.
l Low voltage LED type, pilot lights, Series MML41, 20mA, 3V max; MML44, 20mA, 2.5V max;
MML46, 60mA, 5V max.
l Neon lamp type, pilot light, Series MML43, 250V max.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6231-09.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Cat Nos 3MN1, 3MN6, 3MN8, 3MN17, 3MN19, 3MN241, open-type, single-pole, double-throw
manual motor controllers, rated 15A, 120, 240, 480 or 600V ac, 1/2 hp, 120V ac, 1 hp, 240V ac,
0.8A, 115V dc, 0.4A, 230V dc, pilot duty, 690VA, 600V ac max or B600.
Note: Open type controllers are Certified as components for use only in other Certified equipment where
the suitability of the final combination is to be determined by the Canadian Standards Association.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-3211-04.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Switches, Type WW, open types, 1-, 2- or 3-pole, single throw contacts. Rating Symbols: 1-pole:
A, E; 2-pole: A, C, D, E, F, G; 3-pole: C, D, E and H. Maximum Ratings:
l A 16A, 1/2 hp - 125/250V ac; 3A"L" 125V ac; 150VA pilot duty - 125/250V ac; 24V dc, 2A.
l B (1 pole) 16A (inductive) at 125/250V ac; 3/4 hp at 125/250V ac; 150VA pilot duty at 125/250V
ac, 3A"L", 125V ac.
l C 15A, 1/2 hp - 125V ac; 10A, 1/2 hp - 250V ac; 3A"L" - 125V ac; 150VA pilot duty - 125/250V
ac.
l D 15A, 1/2 hp - 125V ac; 10A, 1/2 hp - 250V ac; 3A"L" - 125V ac; 150VA pilot duty - 125/250V
ac; 0.1A - 125V ac/dc; 24V dc, 2A.
l E 0.1A - 125V ac/dc.
l F 16A, 1/2 hp - 125/250V ac; 3A"L" - 125V ac; 150VA pilot duty - 125/250V ac; 0.1A - 125V
ac/dc.
l G 5A, 125V ac; 24V dc, 2A.
l H 5A (inductive), 125V ac; 2A, 24V dc; 0.1A, 125V ac/dc.
Notes:
1. Suffix letters and/or numbers are added to type designation to indicate type of contact, circuitry,
mechanical variation, electrical ratings and terminal size.
2. For Type WW controllers, all ampere ratings have been tested to 100,000 operations endurance.
3. Open type switches are Certified as components for use only in other Certified equipment, where
the suitability of the combination is to be determined by the Canadian Standards Association.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-3211-05.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Illuminated pushbutton switches, Series 3 with suffix, 1 or 2 pole, single or double throw; with
suffix -A, -E, -F and -G, rated 125V ac, 5A, 28V dc, 3A or 5A resistive; with suffix -B, -H, -K
and -L, rated 125V ac, 0.1A.
Note: Certified for use only as a component of other certified equipment and in circuits where the power
is limited by a transformer, rectifier, voltage divider or similar devices (overload devices and fuses are
excluded) and where the short circuit limit between conductors and between conductors and ground is
1500V ac max and where a fire hazard will not result from a short circuit.
l Switches, Type 1DP with suffixes, open type, rated 14A (inductive), 250V ac 16A (inductive)
277V ac; 3/4 hp, 125/250V ac; 150VA pilot duty at 125/250V ac.
l Switches, type 2DP6 with suffixes, open type, two pole, single throw contacts, contacts rated cct.
No 1, 1A, 125V ac; cct No 2, 14A, 250V ac; 3/4 hp, 125/250V ac; 150VA, pilot duty 125/250V
ac.
Note: The Type 1DP and 2DP6 switches have been endurance tested for 100,000 operations.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-3211-07.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 6
Certification Record
l Code L54, 15A, 125-250V ac, 1/3 hp, 125V ac, 3/4 hp, 250V ac, 1/2A, 125V dc, 1/4A, 250V dc.
l Code L55, 15A, 125-250V ac, 1/2 hp, 125V ac, 1 hp, 250V ac, 1/2A, 125V dc, 1/4A, 250V dc.
l Code L191, 15A, 125-277V ac, 5A, 125V ac (tungsten), 1/2 hp, 125V ac, 1 hp, 250-277V ac.
l Code L192, 10A, 125-277V ac, 3A, 125V ac (Tungsten), 1/4 hp, 125V ac, 1/2 hp, 250-277V ac.
l Prefix numeral 2 (e.g. Cat No 212TS15-1), indicates a switch provided with a panel mounting
seal. Prefix numeral 5 (e.g. 512TS15-1) indicates a neoprene seal on the toggle. Suffix numeral 95
immediately following "11TS" or "12TS" indicates a switch with quick-disconnect type male
terminals to accept either "AMP" or "ARK-LES" female solderless quick-disconnect wire
connectors.
l Type XL, Cat No 37XL, 5V dc, 20mA dc; Cat No 47XL, 6 to 16V dc, 40mA dc.
l Type VX, 4.5 to 24V dc, 0.015A max.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6241-10.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 2 of 6
l Lighted pushbutton, Series 2 with suffixes, rating codes of component switches, Series 4,
followed by suffixes, Code L22, 1A, 125V ac; Code L4, 5A, 250V ac; Code L99, 10A, 1/4 hp,
125 or 250V ac.
l Types NR, NT, TP, TL, Code L191, 15A, 125/250/277V ac, 1/2 hp, 125V ac, 1 hp, 250V ac, 5A,
125V ac (tungsten); Code L192, 10A, 125/250/277V ac, 1/4 hp, 125V ac, 1/2 hp, 250V ac, 3A,
125V ac (tungsten).
l Type TW, Code L117, 5A, 125V ac.
l AML10 Series, electronic switch for use in business machines, lighted or unlighted, electrical
rating 40mA max, 16V dc max; pushbutton, ALM11, 12 with suffixes paddle or rocker, AML13,
14, 15, 16 with suffixes.
l AML20 Series lighted or unlighted, Code L173, 3A, 125V ac 2A, 250V ac, Code L203, 0.1A,
125V; pushbutton AML21, 22 with suffixes; paddle or rocker AML23, 24, 25, 26 with suffixes,
AML27, Code L173, 3A, 125V ac, 2A, 250V ac, Code L203, 0.1A, 125V dc.
l AML21 Series, Cat No AML21BBAZCD-001, lighted, with 2 poles rated code L173, 3A, 125V
ac, two poles rated code L203, 0.1A, 125V ac.
l AML30 Series, lighted or unlighted pushbutton AML31, 32 with suffixes, Code L29, 10A, 250V
ac, Code L93, 10A, 125-250V ac, 1/3 hp, 125-250V ac; paddle or rocker AML33, 34, 35, 36 with
suffixes, Code L186, 15A, 125-250V ac.
l Series MML31, MML83 with suffixes, 6A, 125-250V ac, 2A, 30V dc, 1A, 125V ac (tungsten),
1/10 hp, 125V ac.
l Series MML33 and MML34 with suffixes, single or double-pole, single-throw, 6A, 125V ac; 4A,
250V ac; 2A, 30V dc; 1A, 125V ac (tungsten); 1/10 hp, 125V ac.
l Series MML11, 5V sink.
l Series MML21, MML82 with suffixes silver contacts 1A, 125V ac, gold contacts 0.1A, 30V dc.
l Series MML23, MML24 with suffixes; silver contacts, 1A, 125V ac, gold contacts, 0.1A, 30V dc.
l Type AC, spdt Code No L195, 13A, 1/2 hp, 125 or 250V ac; 1/2A, 125V dc; 1/4A, 250V dc; 5A,
125V ac "L", Cat No 2AC, 3AC, 4AC, 22AC, 23AC, 24AC, with suffixes 1 to 99, with or without
suffix D with numerals, followed by suffix UL.
l Type TB with prefix and suffix numbers.
l Code L22, 1A, 125V ac. Code L25, 10A, 125-250V ac, 1/2 hp, 125V ac.
l Type V4.
l Code No L4, 5A, 250V ac, spdt; 5A, 125 or 250V ac, sp, Cat Nos V4-8 to V4-100, the various
catalogue numbers identify a particular variation of the basic switches, Cat Nos V4-12 (SPNO)
and V4-14 (SPDT), supplied only to manufacturers for assembly of Certified electrical equipment.
l Code L279, 1A, 125V ac; 0.1A, 30V dc, Cat No BZ-RD722-A2.
l Cat No BE-2R2423-P5 rated 30A, 125, 250 or 277V ac. Res: 25A, 125, 250 or 480V ac; 1 hp,
125V ac; 2 hp, 250 or 480V ac; pilot duty 750VA, 480V ac max; 30A res, 277V ac, 71C (30,000
ops).
l Type 1PL-6PL, 111PL; with suffix numbers 1-1000 and 6700-6799, sp with Code L62.
l Type 9PL, with suffix numbers 1-1000, dp, with Code L62 and L251.
l Type 14PL. with suffix numbers 1-1000, sp, with Code L81. Ratings:
l Code L62, 15A, 125-250V ac, 3/4 hp, 125V ac, 1-1/2 hp, 250V ac.
l Code L81, 22A, 125-250-277V ac, 3/4 hp, 125V ac, 1-1/2 hp, 250V ac.
l Code L251, 0.1A, 30V dc.
l Standard Types B, G and R.
l Code No L-1, 15A, 125, 250 or 480V ac.
l Code No L-8, 10A, 125, 250 or 480V ac.
l Code No L-9, 10A, 125, 250 or 480V ac, 1/2A, 125V dc, 1/4A, 250V dc.
l Code No L96, 15A, 125, 250 or 480V ac, 1/2A, 125V dc*, 1/4A, 250V dc*, 1/8 hp, 125V ac, 1/4
hp, 250V ac.
l Single-throw, Cat Nos G*, GC, GD*, GJ, GK, GP, GT*, R*, RC, RD*, RJ, RK, RP, RT*, double-
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6241-10.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 3 of 6
throw, Cat Nos B*, BC, BD*, BJ, BK, BP, BT*.
l Code No L-5, 17A, 125 or 250V ac, Cat No R-H.
l Code L-17, 20A, 125, 250 or 480V ac, 3/4 hp, 125V ac, 1-1/2 hp, 250V ac. Above catalogue
numbers may have suffix numbers and/or letters.
*Only those catalogue numbers marked with an asterisk and having 2, 3, 4, 5, 6, 7, 8, 9 as the first digit
of the suffix, or where "X" appears in the suffix are rated dc and/or ac. All others are rated ac only.
l Type A, single-pole**, single-throw, Cat Nos WA, WAC, WAD, WAE, WAF, WAJ, WAK,
WALK, WALM, WAP, WAT, WAV, YA, YAC, YAD, YAE, YAF, YAJ, YAK, YALK, YALM,
YAP, YAT, YV, followed by a numeral from 1-9 incl., or combination thereof. Single-pole**,
double-throw, Cat Nos BA, BAC, BAD, BAE, BAF, BAJ, BAK, BALK, BALN, BAP, BAT,
BAV, followed by numerals from 1-9 incl., or combination thereof. The catalogue numbers may
have suffix numerals or with one or more of the following suffix letters with or without any
combination of numerals, A, B, C, D, E, F, L, M, N, P, Q, R, S, T, TB, TC, TN, V, W, X.
l Code No L145, 2A, 600V ac, 20A, 125, 250 or 480V ac, 10A, 125V ac, (suitable for controlling
tungsten filament lamp loads), 1 hp, 125V ac, 2 hp, 250V ac, 1/2A, 125V dc, +A, 250V dc.
l Load L65, 15A, 125, 250 or 480V ac, 1/2 hp, 125V ac, 1 hp, 250V ac.
l Code No L50, 17A, 125, 250 or 480V ac, 1 hp, 125V ac, 2 hp, 250V ac, 10A, 125V ac (suitable
for controlling tungsten filament lamp loads), 1/2A, 125V dc, +A, 250V dc.
l Code No L58; 25A, 125, 250, or 480V ac; 3/4 hp, 125V ac; 1-1/2 hp, 250V ac; 1A, 125V dc;
0.5A, 250V dc. (Ref. Report -16).
l Code No L33, 20A, 125, 250 or 480V ac, 1 hp, 125V ac, 2 hp, 250V ac, 0.3A, 125V dc, 0.15A,
250V dc.
l Code No L23, 20A, 125, 250 or 480V ac, 10A, 125V ac (suitable for controlling tungsten filament
lamp loads), 1 hp, 125V ac, 2 hp, 250V ac, 1/2A, 125V dc, 1/4A, 250V dc.
l Code No L-19, 15A, 125, 250 or 480V ac, 3/4 hp, 125V ac, 1-1/2 hp, 250V ac, 1/2A, 125V dc,
1/4A, 250V dc.
l Code No L17, 20A, 125, 250 or 480V ac, 3/4 hp, 125V ac, 1-1/2 hp, 250V ac. Code No L15, 15A,
125, 250 or 480V ac, 10A, 125V ac (suitable for controlling tungsten filament lamp loads), 3/4 hp,
125V ac, 1-1/2 hp, 250V ac, 1/2A, 125V dc, 1/4A, 250V dc.
l Code No L97, 20A, 125, 250 or 480V ac, 10A, 125V ac (tungsten), 1/2A, 125V dc, 1/4A, 250V
dc, 1-1/2 hp, 125V ac, 2 hp, 250V ac.
l Code No L22, 1A, 125V ac.
l Code L178, 20A, 125, 250 or 277V ac, 3/4 hp, 125V ac, 1-1/2 hp, 250V ac.
l Code L179, 20A, 125, 250 or 277V ac, 15A, 480V ac, 5A, 125V ac (tungsten), 1 hp, 125V ac, 2
hp, 250V ac, 1/2A, 125V dc, 1/4A, 250V dc.
l Cat No 6AS216, Code L23, 20A, 125, 250, 480V dc, 10A, 125V ac (tungsten), 1 hp, 125V ac, 2
hp, 250V ac, 1/2A, 125V dc, 1/4A, 250V dc.
l Dpst, Cat Nos DO, DC; Code No L-59, 10A, 125 or 250V ac, 0.3A, 125V dc, 0.15A, 250V dc,
double-throw DT; supplied only to manufacturers for use in Certified factory wired assemblies
where suitable terminal lugs, or equivalent, will be used for terminal connections. Suffix numerals
with following suffix letters may be added to catalogue numbers, A-F incl., K-N incl., P-T incl.,
TB, TC, TN, V, W, X, with or without and combination of numerals.
l Type M, single-pole, single and double-throw, Code No L101, 22A, 125, 480V ac, 1/4 hp, 125V
ac, 1/2 hp, 250V ac, 1/2A, 125V dc, 1/4A, 250V dc; Code L102, 22A, 125-480V ac, 1/4 hp, 125V
ac, 1/2 hp, 250V ac; Code L161, 22A, 125, 250 or 480V ac, 1/2 hp, 125V ac, 1 hp, 250V ac; Code
L167, 22A, 125, 250 or 277V ac, 3/4 hp, 125V ac, 1-1/2 hp, 250V ac, Code L316, 15A, 480V ac,
22A, 125, 277V ac, 1/4 hp, 125V ac, 1/2 hp, 250V ac; Cat Nos BM, WM, YM, with or without
prefix letters D, E, F, T, V, or numeral 6, with suffixes A,B, D, E, L, M, N, P, Q, R, S, T, W or X
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6241-10.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 4 of 6
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6241-10.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 5 of 6
BZ-2R.
l Code L-189, 11A, 125, 250 or 480V ac, 1/8 hp; 125V ac, 1/4 hp, 250V ac, Cat No BZ-PP1.
l Code L-73, 15A, 125, 250 or 480V ac, 1/2 hp, 250V ac, 1/4 hp, 125V ac, 1A, 125V dc, 0.5A,
250V dc, Code L180, 15A, 125, 250, 480V ac, 2A, 600V ac, 1/4 hp, 125V ac, 1/2 hp, 250V ac,
1A, 125V dc, 0.5A, 250V dc, spst or spdt shorting bar switches Cat Nos BZ, BZD, BZE, BZF,
BZLN, BZT, BZV, WZ, WZD, WZE, WZF, WZLN, WZT, WZV, YZ, with or without additional
suffix number or letters. The switches are not intended for connection in a circuit where a
condition of opposite polarity may exist between opposite sides of the contact structure. Code L-
88, 15A, 125, 250, or 480V ac, 1/2A, 125V dc*, 1/4A, 250V dc*, 1/3 hp, 125 or 250V ac, Cat Nos
WZ-2R with or without additional letters or numbers. Code L22, 1A, 125V ac.
*Only those catalogue numbers marked with an asterisk and having 2, 3, 7, as the first digit of the suffix
except Cat Nos BZLN, WZLN, YZLN, or catalogue numbers where the letter "X" appears in the suffix
are rated dc and/or ac. All others are rated ac only.
l Types SM, 32SM, single-pole, single or double-throw, Cat No SM with prefix nos 1, 11, 12, 21,
22, 23, 41, 42, 142, 51, 54, 101, 111, 112, 121, 122, 141, 151, 301, 302, 311, 312, 321, 322, 341,
342, 401, 411, 412, 421, 422 with suffix nos 1 through 10,000 with or without designation T or H,
with or without numbers; those catalogue numbers with suffix D are supplied only to
manufacturers for use in factory wired assemblies or suitable terminal lugs of equivalent will be
used for terminal connections.
l Code L4, 5A, 250V ac.
l Code L22, 1A, 125V ac.
l Code L119, 4A, 250V ac.
l Code L149, 1A, 250V ac.
l Code L150, 5A, 250V ac, 1A, 30V dc.
l Code L151, 5A, 250V ac, 5A, 30V dc.
l Code L171, 0.1A, 125V ac, 0.1A, 30V dc.
l Code L172, 0.3A, 125V dc, 5A, 250V ac.
l Code L184, 1A, 125V ac, 1A, 30V dc.
l Code L185, 4A, 250V ac, 1/10 hp, 125V ac.
l Code L190, 11A 125/250V ac, 1/4 hp 125/250V ac, 5A, 30V dc.
l Code L212, 11A, 125/250V ac, 5A, 30V dc, 1/2A, 125V dc, 1/4 hp, 125/250V ac.
l Code L245, 1A resistive, 0.5A inductive, 30V dc.
l Television Type SM with prefixes and suffixes, Code TV-2, 2A, 120V ac.
l Type 5SM, single, single throw or double throw with suffixes 1 to 1000, 5A, 250V ac; 5A, 30V
dc.
** Suitable for 2A, 600V ac rating when properly installed in Certified electrical equipment.
Note: The above switches are supplied only to manufacturers for assembly of Certified electrical
equipment.
l Switches, open type, spdt, Cat No BE, spst, Cat Nos WE and YE, two single pole, single or
double-throw, Cat Nos 6AS112, 6AS132 and 6AS143, 6AS230; max ratings, 480V ac max, 25A
max, 480V ac max, 2 hp max, 480V ac max, 750VA max (pilot duty), with suffixes -1 or -2,
100,000 cycles, Cat No 6AS216, ratings 20A - 125/250/480V ac, 10A, 125V ac (tungsten); 1 hp-
125V ac, 2 hp-250V ac; 1/2A, 125V dc; 1/4A, 250V dc.
l Type 6AS5, Code L96, 15A, 125, 250 or 480V ac, 1/8 hp, 125V ac, 1/4 hp, 250V ac, 1/2A, 125V
dc, 1/4A, 250V dc.
l Type SX, single-pole, with prefixes and suffixes, with or without "T".
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6241-10.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 6 of 6
Notes:
1. For Cat No BE, suffix letters and numbers are added to the catalogue designation to denote the
contact break distance type of actuator are wire terminals, etc.
2. These switches are Certified for use only as components in other equipment where the
acceptability of the combination has been determined by the Canadian Standards Association.
3. Series 713 ribbon chrome labels can be used for markings.
/ns
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6241-10.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Switches, Type WW, open types, 1-, 2- or 3-pole, single throw contacts. Rating Symbols: 1-pole:
A, E; 2-pole: A, C, D, E, F, G; 3-pole: C, D, E and H. Maximum Ratings:
l A 16A, 1/2 hp - 125/250V ac; 3A"L" 125V ac; 150VA pilot duty - 125/250V ac; 24V dc, 2A.
l B (1 pole) 16A (inductive) at 125/250V ac; 3/4 hp at 125/250V ac, 150VA pilot duty at 125/250V
ac, 3A"L", 125V ac.
l C 15A, 1/2 hp - 125V ac; 10A, 1/2 hp - 250V ac; 3A"L" - 125V ac; 150VA pilot duty - 125/250V
ac.
l D 15A, 1/2 hp - 125V ac; 10A, 1/2 hp - 250V ac; 3A"L" - 125V ac; 150VA pilot duty - 125/250V
ac; 0.1A - 125V ac/dc; 24V dc, 2A.
l E 0.1A - 125V ac/dc.
l F 16A, 1/2 hp - 125/250V ac; 3A"L" - 125V ac; 150VA pilot duty - 125/250V ac; 0.1A - 125V
ac/dc.
l G 5A, 125V ac; 24V dc, 2A.
l H 5A (inductive), 125V ac; 2A, 24V dc; 0.1A, 125V ac/dc.
Notes:
1. Suffix letters and/or numbers are added to type designation to indicate type of contact, circuitry,
mechanical variation, electrical ratings and terminal size.
2. For Type WW controllers, all ampere ratings have been tested to 100,000 operations endurance.
3. Open type switches are Certified as components for use only in other Certified equipment, where
the suitability of the combination is to be determined by the Canadian Standards Association.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-3211-85.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Cat No BE-2R2423-P5 rated 30A, 125, 250 or 277V ac. Res: 25A, 125, 250 or 480V ac; 1 hp,
125V ac; 2 hp, 250 or 480V ac; pilot duty 750VA, 480V ac max; 30A res, 277V ac, 71C (30,000
ops).
http://directories.csa-international.org/xml_transform.asp?xml=certxml\397-6241-90.xml&xsl=xsl/certrec.xsl
... 12/3/2002
Page 1 of 1
Certification Record
l Gas Safety Control (pilot) Valve, rated up to 16BAR (232psig), -55ºC to +90ºC, typical control fluid is air or gases
1. Type FP10P valve body is evaluated for use with ‘Bifold Fluid Power Ltd.’ solenoid operator, FP Series, (refer to
CSA Report 1398692).
2. Suitability of mating the valve body with other CSA Certified, UL Listed operators is to be evaluated by CSA
International.
3. Not evaluated for fuel service.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\215681-3228-01.xml&xsl=xsl/certre... 3/4/2008
Page 1 of 1
Gas Safety Control (pilot) Valve, rated up to 16BAR (232psig), -55ºC to +90ºC, typical control fluid is air or gases
1. Type FP10P valve body is evaluated for use with ‘Bifold Fluid Power Ltd.’ solenoid operator, FP Series, (refer to
CSA Report 1398692).
2. Suitability of mating the valve body with other CSA Certified, UL Listed operators is to be evaluated by CSA
International.
3. Not evaluated for fuel service.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\215681-3228-81.xml&xsl=xsl/certre... 3/4/2008
Page 1 of 2
Appliance circuit protectors, open types, trip-free, thermally operated, manually reset, with or without manual switching
feature:
No Poles Rating
1 0.5-50A, 277V ac, 180V dc
2 0.5-50A, 480V ac, 360V dc
3 0.5-50A, 480V ac, 360V dc
4 0.5-50A, 480V/277V ac
Notes:
1. These devices are Certified as components for use only in other Certified equipment where the suitability of the
combination is to be determined by CSA International.
2. The circuit protectors were short circuit tested without series fuses at 5,000A, 277V ac, 1-ph; 5,000A, 480V ac, 3-
ph and 10,000A, 240V dc. Circuit protectors with short circuit ratings other than these are suitable for use in
circuits where they are protected by fuses rated not more than four times the full load current of the devices, except
the minimum fuse may be 15A.
3. Trip ratings are 125 percent of the full load current. The circuit protectors may be used to control motors having
full load motor currents not exceeding the main contact full load ratings.
4. The type designation is completed with letters and numbers indicating number of poles, tripping characteristics,
ampere rating, etc.
5. These devices have application codes as follows:
No. of Volts Amperes Tripping Current Overload Short
Poles Circuit
1 125V ac 0.5 - 50A TC1 OL0 U2, 10kA
1 277V ac 0.5 - 50A TC1 OL0 U2, 3kA
2, 3 240V ac 0.5 - 50A TC1 OL0 U2, 5kA
2, 3 480V ac 0.5 - 50A TC1 OL0 U2, 3kA
1, 2, 3, 4 65V dc (ac version) 0.5 - 50A TC1 OL0 U1, 2kA
1 120V dc 0.5 - 40A TC1 OL0 U1, 10kA
2 240V dc 0.5 - 40A TC1 OL0 U1, 10kA
http://directories.csa-international.org/xml_transform.asp?xml=certxml\166382-3215-30.xml&xsl=xsl/certr... 3/21/2008
Page 2 of 2
3 360V dc 0.5 - 40A TC1 OL0 U1, 10kA
1, 2 180V dc/360V dc 0.5 - 50A TC1 OL0 U1, 2kA
1 277V ac 0.5 - 50A TC1 OL0 U1, 5kA
2, 3 480V ac 0.5 - 50A TC1 OL0 U1, 5kA
1 240V ac 0.5 - 40A TC1 OL0 C1, 10kA
3 480V ac 0.5 - 40A TC1 OL0 C1, 10kA
/ka
http://directories.csa-international.org/xml_transform.asp?xml=certxml\166382-3215-30.xml&xsl=xsl/certr... 3/21/2008
Page 1 of 5
Class I, Division 2, Groups A, B, C and D; Class II & III, Division 1, Groups E, F and G, T4; Amb. -40°C to +85°C:
POINTEK Model CLS100 Series Capacitance Level Switch, Model Numbers CLS100 - abc-d; rated 10 - 33 Vdc,
4 to 20 mA, intrinsically safe with intrinsically safe probe when connected in accordance with Pointek Control
Drawing A10174R0.
Notes:
1. The above model numbers include suffixes designating indicator type, output signal, electrical connection, and
options.
2. The suitability of the final installation is to be determined by the local authorities having jurisdiction.
Class I, Groups A, B, C and D; Class II, Groups E, F and G; Class III; T4; Encl Type 4:
POINTEK CLS200 Series Capacitance Level Switches, Model Numbers CLS200 C2a-bcd-ef, rated 12 to 250
Vac/dc, 2 VA max; with intrinsically safe, Ex ia, probe for use in Hazardous Locations. Maximum working
pressure of 2517 kPa for rigid versions and 1034 kPa for cable versions.
Where:
a = version
b = process connection
c = approvals
d = options
e = extended length
f = units
POINTEK CLS300 Series Capacitance Level Switch, Model Numbers CLS300 C3a-bcd-ef, rated 12 to 250
Vac/dc, 2 VA max; with intrinsically safe, Ex ia, probe for use in Hazardous Locations. Max working pressure of
3500 kPa for both the rigid version and for the cable version.
Series Capacitance Level Switches, POINTEK Model Numbers CLS300 C3a-bcd-ef, rated 12 to 250 Vac/dc, 2
VA max and Sitrans Model LC 300, rated 12-30 Vdc, 4-20 mA; with intrinsically safe, Ex ia, probe for use in
Hazardous Locations. Maximum working pressure of 3500 kPa for both rigid and cable versions.
Class II, Groups E, F and G; Class III; T4; Encl Type 4; Max Amb. 85°C:
POINTEK CLS300 Series Capacitance Level Switch, Model Numbers CLS300 C3a-bcd-ef, rated 12 to 250
Vac/dc, 2 VA max; with intrinsically safe, Ex ia, probe for use in Hazardous Locations. Max working pressure of
3500 kPa for both the rigid version and for the cable version.
file://C:\Temp\C1KL3EUB.htm 5/28/2008
Page 2 of 5
Where:
a = version
b = process connection
c = approvals
d = options
e = extended length
f = units
Series Capacitance Level Switches, POINTEK Model Numbers CLS300 C3a-bcd-ef, rated 12 to 250 Vac/dc, 2
VA max and Sitrans Model LC 300, rated 12-30 Vdc, 4-20 mA; with intrinsically safe, Ex ia, probe for use in
Hazardous Locations. Maximum working pressure of 3500 kPa for both rigid and cable versions.
Series Capacitance Level Switches, POINTEK Model Numbers CLS300 C3a-bcd-ef, rated 12 to 250 Vac/dc, 2
VA max and Sitrans Model LC 300, rated 12-30 Vdc, 4-20 mA; with probe for use Ordinary Locations. Max
working pressure of 3500 kPa for both rigid and cable versions.
Where:
a = version
b = process connection
c = approvals
d = options
e = extended length
f = units
POINTEK Model CLS 500 Series Capacitive Level and Flow Through Transmitter,
Model Numbers 7ML560a-bcde-1fA0 and 7ML5604-bAcd-gehf, rated 12 - 32 V, 4 - 20 mA, with solid state
output switch, rated 30 Vdc or ac, 100 mA.
SITRANS Model LC 500 Series Capacitive Level and Flow Through Transmitter, Model Numbers 7ML55a-bcd-
ef, rated 12 - 32 V, 4 - 20 mA, with solid state output switch, rated 30 Vdc or ac, 100 mA.
Enclosure Type 4, Ambient temperature -40 °C ... +85 °C, Temperature Class T4
Maximum working pressure for both the compact versions and for the cable versions - refer to instruction manual.
file://C:\Temp\C1KL3EUB.htm 5/28/2008
Page 3 of 5
POINTEK Model CLS 200 Series Capacitive Level Switch, Model No. 7ML5502-bbcde-0fgh-z and Model
No. 7ML550a-bbccd-efgh-z, with solid state output switch; input rated 30 Vdc; solid state output switch rated
33 V dc or ac, 100 mA..
- POINTEK Model CLS 300 Series Capacitive Level Switch, Model No. 7ML55aa-bbcde-fgAh-z and Model
No. 7MLaa-bbccd-egfh-z, with solid state output switch; input rated 30 Vdc; solid state output switch rated
33 V dc or ac, 100 mA..
SITRANS LC 300 Series Capacitive Level Transmitter, Model No. 7ML56aa-bcdde-fgA0, with solid state output switch;
input rated 30 Vdc; solid state output switch rated 33 V dc or ac, 100 mA..
Enclosure Type 4, Ambient temperature -40 °C ... +85 °C, Temperature Class T4 or T6
a = Product code 4 or 5
bb = Version 0X, 1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1K, 1L, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 3A,
cc = Process Connection, Size and Rating A1, A2, A3, B1, B2, B3, C1, C2, C3, D1, D2, D3, E1,
E2, E3, J4, J6, K4, K6, L4, L6, M4, M6, N4 or N6
d = Approvals 2 or 3
e = Enclosure 1 or 2
f = Additional options A, B, C, D, E, F, G or H
z = Additional information (not in code): Y15, A01, A02, A03, A04, A22, C12, A05 or A06.
bb = Version 0X, 1A, 1B, 1C, 1D, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 3A, 3B, 3C, 3D, 3E, 3F or 3G
cc = Process Connection A1, A2, A3, B1, B2, B3, C1, C2, C3, D1, D2, D3, E1, E2, E3, J4, J6, K4,
d = Approvals 2 or 3
file://C:\Temp\C1KL3EUB.htm 5/28/2008
Page 4 of 5
e = WHG approval 0 or 1
f = Enclosure A, B, C, D, 0, 1, 2 or 3
g = Options A or B
z = Additional information (not in code): Y01, Y15, A01, A02, A03, A04, A22, C12, A05 or A06.
aa = Threaded or Welded 25 or 26
c = Version A, B, C, D, E, F, G, or H
dd = Process Connection A0, B0, C0, D0, E0, F0, G0, H0, J0, K0, A1, A2, A3, B1, B2, B3, C1, C2, C3, D1,
D2, D3, E1, E2, E3, J4, J6, K4, K6, L4, L6, M4, M6, N4 or N6
e = Approvals 2 or 3
f = Thermal Isolator 0 or 1
g = Enclosure A, B, C, D
z = Additional information (not in code): Y01, Y15, A01, A02, A03, A04, A22, C12, A05 or A06.
Class I, Division 1, Explosion proof, Group A,B,C,D, Type 4, Tamb -40 °C to +70 °C, T4
Capacitance Level and Flow Measurement System, SITRANS LC500 and POINTEK CLS500 Series; rated 12-
30Vdc, 2 VA maximum; with Intrinsicaly Safe, Ex ia probe
- POINTEK Model CLS 500 Series Capacitive Level and Flow Through Transmitter,
Model Numbers 7ML560a-bcde-l fAO and 7ML5604-bAcd-gehf, rated 12 - 32 V, 4 - 20 mA, with solid state
output switch, rated 30 Vdc or ac, 100 mA.
- SITRANS Model LC 500 Series Capacitive Level and Flow Through Transmitter,
Model Numbers 7ML55a-bcd-ef, rated 12 - 32 V, 4 - 20 mA, with solid state output switch, rated 30 Vdc or
ac,100mA.
file://C:\Temp\C1KL3EUB.htm 5/28/2008
Page 5 of 5
c = process connection size and type and/or pressure rating (2 digits)
d =approvals (B)
e = variations not safety relevant (3 digits)
f= transmitter type; 0 =none, I = 3300 pF range
Enclosure Type 4, Ambient temperature -40°C ... +85 °C, Temperature Class T4
/gp
file://C:\Temp\C1KL3EUB.htm 5/28/2008
Page 1 of 15
CATEGORIES:
Programmable Controllers
Input/Output Modules
Communications Modules
Scanners - Memory Modules
Chassis Assemblies
Processors
Power Supplies
Programmers Industrial Work Stations
Notes:
1. These units are for use in programmable controller systems in conditions up to a 60C max ambient. A 120V ac
nominal input power is suitable for a range of 97 to 132V ac. A 220 or 240V ac nominal input power is suitable for
a range of 195 to 264V ac.
2. The units are Certified as components for use only in other Certified equipment where the suitability of the
combination is to be determined by CSA International.
3. The Catalogue numbers may be expressed in the format of "Catalogue Number" space "Letter" or "Catalogue
Number" series "Letter" or "Catalogue Number"/"Letter " or "Catalogue Number" or "Letter"; where the "Letter"
is the series designation if not specified, then the series is "A".
4. The Catalogue numbers may be followed by a "K" which indicates the unit has a conformal coating.
5. Khrones catalogue numbers may or may not be proceeded by the letter "K".
6. The prefix "TK" may be used in place of "TC" indicating that the unit has conformal coating.
7. All products evaluated to CSA C22.2 No. 213.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 5 of 15
1771-ACN B CSA C22.2 No. 142
1771-ACN15 B CSA C22.2 No. 142
1771-ACNR A CSA C22.2 No. 142
1771-ACNR B CSA C22.2 No. 142
1771-ACNR15 B CSA C22.2 No. 142
1771-AF A CSA C22.2 No. 142
1771-AF1 A CSA C22.2 No. 142
1771-ALX A CSA C22.2 No. 142
1771-ASB C CSA C22.2 No. 142
1771-ASB D CSA C22.2 No. 142
1771-ASB E CSA C22.2 No. 142
1771-ASB E CSA C22.2 No. 142
1771-CFM A CSA C22.2 No. 142
1771-CFM B CSA C22.2 No. 142
1771-CFM C CSA C22.2 No. 142
1771-DA A CSA C22.2 No. 142
1771-DMC A CSA C22.2 No. 142
1771-DMC1 A CSA C22.2 No. 142
1771-DMC4 A CSA C22.2 No. 142
1771-DRS A CSA C22.2 No. 142
1771-DRS1 A CSA C22.2 No. 142
1771-DRS4 A CSA C22.2 No. 142
1771-DTC A CSA C22.2 No. 142
1771-DXPS A CSA C22.2 No. 142
1771-IA A CSA C22.2 No. 142
1771-IA B CSA C22.2 No. 142
1771-IA C CSA C22.2 No. 142
1771-IAD D CSA C22.2 No. 142
1771-IB A CSA C22.2 No. 142
1771-IBD B CSA C22.2 No. 142
1771-IBN A CSA C22.2 No. 142
1771-IBN A CSA C22.2 No. 142
1771-IBN B CSA C22.2 No. 142
1771-IBN C CSA C22.2 No. 142
1771-IBN C CSA C22.2 No. 142
1771-ICD B CSA C22.2 No. 142
1771-ID16 A CSA C22.2 No. 142
1771-ID16 B CSA C22.2 No. 142
1771-ID16GM A CSA C22.2 No. 142
1771-ID16GM B CSA C22.2 No. 142
1771-IFE A CSA C22.2 No. 142
1771-IFE B CSA C22.2 No. 142
1771-IFE C CSA C22.2 No. 142
1771-IFF A CSA C22.2 No. 142
1771-IL D CSA C22.2 No. 142
1771-IQ16 A CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 6 of 15
1771-IQ16 B CSA C22.2 No. 142
1771-IQ16 C CSA C22.2 No. 142
1771-IR D CSA C22.2 No. 142
1771-IXE D CSA C22.2 No. 142
1771-IXHR C CSA C22.2 No. 142
1771-KRF A CSA C22.2 No. 142
1771-KRF B CSA C22.2 No. 142
1771-LI A CSA C22.2 No. 142
1771-LIA A CSA C22.2 No. 142
1771-LIA2 A CSA C22.2 No. 142
1771N-0LLLLLRRR C CSA C22.2 No. 142
1771N-0LLLLRRRR C CSA C22.2 No. 142
1771N-0LLLTTTTT C CSA C22.2 No. 142
1771N-0LLRRRRRR C CSA C22.2 No. 142
1771N-0LLRRTTTT C CSA C22.2 No. 142
1771N-0LLTTTTTT C CSA C22.2 No. 142
1771N-0NNRRTTVV C CSA C22.2 No. 142
1771N-0NNTTTTTT C CSA C22.2 No. 142
1771N-0PPPPPPVV C CSA C22.2 No. 142
1771N-0PPPPPTTT C CSA C22.2 No. 142
1771N-1FNNNNNNN C CSA C22.2 No. 142
1771N-2BDRRRRRT C CSA C22.2 No. 142
1771N-2DDLLLTTT C CSA C22.2 No. 142
1771N-2DDLLTTTT C CSA C22.2 No. 142
1771N-2DDPPRRRR C CSA C22.2 No. 142
1771N-2DFLNPRTV C CSA C22.2 No. 142
1771N-3FFFNNNNN C CSA C22.2 No. 142
1771N-3FFFNNNTT C CSA C22.2 No. 142
1771N-4BDBDRRRT C CSA C22.2 No. 142
1771N-4BDBDRRTT C CSA C22.2 No. 142
1771N-4DDDDLLLL C CSA C22.2 No. 142
1771N-4DDDDNNNN C CSA C22.2 No. 142
1771N-4DDDDRRTT C CSA C22.2 No. 142
1771N-4DDDFNNNN C CSA C22.2 No. 142
1771N-4DDFFLNRV C CSA C22.2 No. 142
1771N-4DDFFLPRT C CSA C22.2 No. 142
1771N-4DDFFNNPP C CSA C22.2 No. 142
1771N-4FFFFNNNN C CSA C22.2 No. 142
1771N-5BDBDDRRT C CSA C22.2 No. 142
1771N-6FFFFFFNN C CSA C22.2 No. 142
1771-NB4S C CSA C22.2 No. 142
1771-NB4T C CSA C22.2 No. 142
1771-NBRC C CSA C22.2 No. 142
1771-NBSC C CSA C22.2 No. 142
1771-NBTC C CSA C22.2 No. 142
1771-NBV1 C CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 7 of 15
1771-NBVC C CSA C22.2 No. 142
1771-NIS C CSA C22.2 No. 142
1771-NIV C CSA C22.2 No. 142
1771-NIV1 C CSA C22.2 No. 142
1771-NIVR C CSA C22.2 No. 142
1771-NIVT C CSA C22.2 No. 142
1771-NOC C CSA C22.2 No. 142
1771-NOV C CSA C22.2 No. 142
1771-NR C CSA C22.2 No. 142
1771-NT1 C CSA C22.2 No. 142
1771-NT2 C CSA C22.2 No. 142
1771N-XXXXXXXXX A CSA C22.2 No. 142 "X’ may be any letter A-Z or number 0-9
1771N-XXXXXXXXX B CSA C22.2 No. 142 "X’ may be any letter A-Z or number 0-9
1771N-XXXXXXXXX C CSA C22.2 No. 142 "X’ may be any letter A-Z or number 0-9
1771-OAD B CSA C22.2 No. 142
1771-OAD C CSA C22.2 No. 142
1771-OBD A CSA C22.2 No. 142
1771-OBD C CSA C22.2 No. 142
1771-OBDS B CSA C22.2 No. 142
1771-OBN A CSA C22.2 No. 142
1771-OBN B CSA C22.2 No. 142
1771-OBN B CSA C22.2 No. 142
1771-OD16 A CSA C22.2 No. 142
1771-OD16 B CSA C22.2 No. 142
1771-ODD B CSA C22.2 No. 142
1771-OFE1 B CSA C22.2 No. 142
1771-OFE2 B CSA C22.2 No. 142
1771-OFE3 B CSA C22.2 No. 142
1771-OQ16 B CSA C22.2 No. 142
1771-OQ16 C CSA C22.2 No. 142
1771-OVN B CSA C22.2 No. 142
1771-OW A CSA C22.2 No. 142
1771-OW16 B CSA C22.2 No. 142
1771-P4 A CSA C22.2 No. 142
1771-P5 A CSA C22.2 No. 1010-92
1771-P5E B CSA C22.2 No. 1010-92
1771-P7 D CSA C22.2 No. 142
1771-PSC A CSA C22.2 No. 142
1771-SDN A CSA C22.2 No. 142
1771-SDN B CSA C22.2 No. 142
1771-SN A CSA C22.2 No. 142
1771-SN B CSA C22.2 No. 142
1771-TCM D CSA C22.2 No. 142
1771-TCMR B CSA C22.2 No. 142
1771-VHSC B CSA C22.2 No. 142
1772-ME A CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 8 of 15
1772-ME16 A CSA C22.2 No. 142
1772-ME8 A CSA C22.2 No. 142
1772-SD A CSA C22.2 No. 142
1772-SD2 A CSA C22.2 No. 142
1784-CPCIDS A CSA C22.2 No. 142
1784-KTCS B CSA C22.2 No. 142
1784-KTCX15 A CSA C22.2 No. 142
1784-KTCX15 B CSA C22.2 No. 142
1784-PCIC A CSA C22.2 No. 142
1784-PCIC B CSA C22.2 No. 1010-92
1784-PCICS A CSA C22.2 No. 142
1784-PCICS B CSA C22.2 No. 1010-92
1784-PCID A CSA C22.2 No. 142
1784-PCIDS A CSA C22.2 No. 142
1784-PCIDS B CSA C22.2 No. 1010-92
1784-PKTCS B CSA C22.2 No. 1010-92
1785-BCM A CSA C22.2 No. 142
1785-BCM B CSA C22.2 No. 142
1785-BCM C CSA C22.2 No. 142
1785-BEM A CSA C22.2 No. 142
1785-BEM B CSA C22.2 No. 142
1785-CHBM A CSA C22.2 No. 142
1785-ENET B CSA C22.2 No. 142
1785-ENET C CSA C22.2 No. 142
1785-KE B CSA C22.2 No. 142
1785-KE C CSA C22.2 No. 142
1785-L11B E CSA C22.2 No. 142
1785-L20B E CSA C22.2 No. 142
1785-L20C E CSA C22.2 No. 142
1785-L20C15 F CSA C22.2 No. 142
1785-L20E E CSA C22.2 No. 142
1785-L20E F CSA C22.2 No. 142
1785-L26B E CSA C22.2 No. 142
1785-L30B E CSA C22.2 No. 142
1785-L40B E CSA C22.2 No. 142
1785-L40C E CSA C22.2 No. 142
1785-L40C15 F CSA C22.2 No. 142
1785-L40E E CSA C22.2 No. 142
1785-L40E F CSA C22.2 No. 142
1785-L40L E CSA C22.2 No. 142
1785-L46B E CSA C22.2 No. 142
1785-L46C15 F CSA C22.2 No. 142
1785-L60B E CSA C22.2 No. 142
1785-L60L E CSA C22.2 No. 142
1785-L66B C CSA C22.2 No. 142
1785-L66L C CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 9 of 15
1785-L80B E CSA C22.2 No. 142
1785-L80C E CSA C22.2 No. 142
1785-L80C15 F CSA C22.2 No. 142
1785-L80E E CSA C22.2 No. 142
1785-L80E F CSA C22.2 No. 142
1785-L86B E CSA C22.2 No. 142
1785-LT B CSA C22.2 No. 142
1785-LT2 A CSA C22.2 No. 142
1785-LT3 A CSA C22.2 No. 142
1785-LT4 A CSA C22.2 No. 142
1785-M100 A CSA C22.2 No. 142
1785-ME16 A CSA C22.2 No. 142
1785-ME32 A CSA C22.2 No. 142
1785-ME64 A CSA C22.2 No. 142
1785-MJ A CSA C22.2 No. 142
1785-MR A CSA C22.2 No. 142
1785-MS A CSA C22.2 No. 142
1785-PFB A CSA C22.2 No. 142
1785-RC A CSA C22.2 No. 142
1786-RPA A CSA C22.2 No. 142
1786-RPA B CSA C22.2 No. 1010-92
1786-RPCD A CSA C22.2 No. 142
1786-RPFM A CSA C22.2 No. 142
1786-RPFS A CSA C22.2 No. 142
1788-CN2DN A CSA C22.2 No. 142
1788-CNC A CSA C22.2 No. 142
1788-CNCR A CSA C22.2 No. 142
1788-CNF A CSA C22.2 No. 142
1788-CNFR A CSA C22.2 No. 142
1791-0A16 B CSA C22.2 No. 142
1791-0A32 B CSA C22.2 No. 142
1791-0B16 B CSA C22.2 No. 142
1791-0B32 B CSA C22.2 No. 142
1791-16A0 B CSA C22.2 No. 142
1791-16AC B CSA C22.2 No. 142
1791-16B0 B CSA C22.2 No. 142
1791-16BC B CSA C22.2 No. 142
1791-24AR B CSA C22.2 No. 142
1791-24B8 B CSA C22.2 No. 142
1791-24BR B CSA C22.2 No. 142
1791-32A0 B CSA C22.2 No. 142
1791-32B0 B CSA C22.2 No. 142
1791-8AC B CSA C22.2 No. 142
1791-8AR B CSA C22.2 No. 142
1791-8BC B CSA C22.2 No. 142
1791-8BR B CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 10 of 15
1791-IOBW A CSA C22.2 No. 142
1791-IOBX A CSA C22.2 No. 142
1791-IOVW A CSA C22.2 No. 142
1791-IOVX A CSA C22.2 No. 142
1791-N4C2 A CSA C22.2 No. 142
1791-N4V2 A CSA C22.2 No. 142
1791-NDC A CSA C22.2 No. 142
1791-NDV A CSA C22.2 No. 142
1792D-0B4D B CSA C22.2 No. 142
1792D-0B8D B CSA C22.2 No. 142
1792D-0VT16E B CSA C22.2 No. 142
1792D-12BVT4D B CSA C22.2 No. 142
1792D-16BVT0D B CSA C22.2 No. 142
1792D-2BV0D B CSA C22.2 No. 142
1792D-2BVA2D B CSA C22.2 No. 142
1792D-4BV0D B CSA C22.2 No. 142
1792D-4BVT4D B CSA C22.2 No. 142
1792D-8BIO8E B CSA C22.2 No. 142
1792D-8BV0D B CSA C22.2 No. 142
1792D-8BVT0D B CSA C22.2 No. 142
1792D-8BVT8D B CSA C22.2 No. 142
1792D-CB12 B CSA C22.2 No. 142
1792D-CB12JP B CSA C22.2 No. 142
1792D-CB18 B CSA C22.2 No. 142
1792D-CB18JP B CSA C22.2 No. 142
1792D-CB18P B CSA C22.2 No. 142
1792D-CB18PT B CSA C22.2 No. 142
1792D-CBFM B CSA C22.2 No. 142
1792-IB16A A CSA C22.2 No. 142
1792-IB16A B CSA C22.2 No. 142
1792-IB16S A CSA C22.2 No. 142
1792-IB16S B CSA C22.2 No. 142
1792-IB2XOB2EA A CSA C22.2 No. 142
1792-IB2XOB2EA B CSA C22.2 No. 142
1792-IB2XOB2ES A CSA C22.2 No. 142
1792-IB2XOB2ES B CSA C22.2 No. 142
1792-IB4A A CSA C22.2 No. 142
1792-IB4A B CSA C22.2 No. 142
1792-IB4S A CSA C22.2 No. 142
1792-IB4S B CSA C22.2 No. 142
1792-IB8A A CSA C22.2 No. 142
1792-IB8A B CSA C22.2 No. 142
1792-IB8S A CSA C22.2 No. 142
1792-IB8S B CSA C22.2 No. 142
1792-OB4EA A CSA C22.2 No. 142
1792-OB4EA B CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 11 of 15
1792-OB4ES A CSA C22.2 No. 142
1792-OB4ES B CSA C22.2 No. 142
1794-ACN A CSA C22.2 No. 142
1794-ACN15 C CSA C22.2 No. 142
1794-ACNR A CSA C22.2 No. 142
1794-ACNR15 C CSA C22.2 No. 142
1794-ADN B CSA C22.2 No. 142
1794-ASB D CSA C22.2 No. 142
1794-ASB E CSA C22.2 No. 142
1794-ASB2 C CSA C22.2 No. 142
1794-ASB2 D CSA C22.2 No. 142
1794-ASBLT D CSA C22.2 No. 142
1794-FLA A CSA C22.2 No. 1010-92
1794-IA8 A CSA C22.2 No. 142
1794-IA8I A CSA C22.2 No. 142
1794-IB10XOB6 A CSA C22.2 No. 142
1794-IB16 A CSA C22.2 No. 142
1794-IB8 A CSA C22.2 No. 142
1794-IB8S A CSA C22.2 No. 142
1794-IE4XOE2 B CSA C22.2 No. 142
1794-IE8 B CSA C22.2 No. 142
1794-IF2XOF2I A CSA C22.2 No. 142
1794-IF4I A CSA C22.2 No. 142
1794-IJ2 A CSA C22.2 No. 142
1794-IR8 A CSA C22.2 No. 142
1794-IRT8 A CSA C22.2 No. 142
1794-IRT8 B CSA C22.2 No. 142
1794-IT8 A CSA C22.2 No. 142
1794-IV16 A CSA C22.2 No. 142
1794-L33 A CSA C22.2 No. 1010-92
1794-L34 B CSA C22.2 No. 1010-92
1794-OA8 A CSA C22.2 No. 142
1794-OA8I A CSA C22.2 No. 142
1794-OB16 A CSA C22.2 No. 142
1794-OB16P A CSA C22.2 No. 142
1794-OB8 A CSA C22.2 No. 142
1794-OB8EP A CSA C22.2 No. 142
1794-OE4 B CSA C22.2 No. 142
1794-OF4I A CSA C22.2 No. 142
1794-OV16 A CSA C22.2 No. 142
1794-OV16 A CSA C22.2 No. 142
1794-OV16P A CSA C22.2 No. 142
1794-OW8 A CSA C22.2 No. 142
1794-TB2 A CSA C22.2 No. 142
1794-TB3 A CSA C22.2 No. 142
1794-TB3G A CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 12 of 15
1794-TB3GS A CSA C22.2 No. 142
1794-TB3S A CSA C22.2 No. 142
1794-TB3T A CSA C22.2 No. 142
1794-TB3TS A CSA C22.2 No. 142
1794-TBN A CSA C22.2 No. 142
1799D-0B4DAB A CSA C22.2 No. 142
1799D-0B4DAB B CSA C22.2 No. 142
1799D-0B8DAB A CSA C22.2 No. 142
1799D-0B8DAB B CSA C22.2 No. 142
1799D-0VT16EAB B CSA C22.2 No. 142
1799D-12BVT4DAB B CSA C22.2 No. 142
1799D-16BVT0DAB B CSA C22.2 No. 142
1799D-2BV0DAB A CSA C22.2 No. 142
1799D-2BV0DAB B CSA C22.2 No. 142
1799D-2BVA2DAB B CSA C22.2 No. 142
1799D-4BV0DAB B CSA C22.2 No. 142
1799D-4BVT4DAB B CSA C22.2 No. 142
1799D-8BVT0DAB B CSA C22.2 No. 142
1799D-8BVT8DAB B CSA C22.2 No. 142
96195833 NA CSA C22.2 No. 142
96196033 NA CSA C22.2 No. 142
96257434 NA CSA C22.2 No. 142
9900-16ADN A CSA C22.2 No. 142
9900-16IE4XOE2 B CSA C22.2 No. 142
9900-16OE4 A CSA C22.2 No. 142
9904-KTCX15 B CSA C22.2 No. 142
9904-PCIC A CSA C22.2 No. 142
9904-RPA A CSA C22.2 No. 142
9904-RPFM A CSA C22.2 No. 142
9904-RPFS A CSA C22.2 No. 142
D100-DTC A CSA C22.2 No. 142
K5745960021 D CSA C22.2 No. 142
K5745960021 E CSA C22.2 No. 142
K5745960022 A CSA C22.2 No. 142
K5745960027 A CSA C22.2 No. 142
K5745960028 A CSA C22.2 No. 142
K5745960032 B CSA C22.2 No. 142
K5745960033 B CSA C22.2 No. 142
K5745960048 A CSA C22.2 No. 142
K5745960051 A CSA C22.2 No. 142
K5745960053 A CSA C22.2 No. 142
K5745999582 C CSA C22.2 No. 142
K5745999622 B CSA C22.2 No. 142
K5745999626 B CSA C22.2 No. 142
P0-912DV A CSA C22.2 No. 142
P0-912DV C CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 13 of 15
RSD-CFACN A CSA C22.2 No. 142
RSD-CFACN B CSA C22.2 No. 1010-92
RSD-FC2CN3KM A CSA C22.2 No. 142
RSD-GW2CN C CSA C22.2 No. 142
S200-ACN A CSA C22.2 No. 142
S200-ACN15 A CSA C22.2 No. 142
S200-ACNR A CSA C22.2 No. 142
S200-ACNR15 A CSA C22.2 No. 142
S200-ADN A CSA C22.2 No. 142
S200-ANN A CSA C22.2 No. 142
S200-IA8 A CSA C22.2 No. 142
S200-IA8I A CSA C22.2 No. 142
S200-IB10XOB6 A CSA C22.2 No. 142
S200-IB16 A CSA C22.2 No. 142
S200-IB8 A CSA C22.2 No. 142
S200-IE4XOE2 A CSA C22.2 No. 142
S200-IE4XOE2 B CSA C22.2 No. 142
S200-IE8 B CSA C22.2 No. 142
S200-IF2XOF2I A CSA C22.2 No. 142
S200-IF4I A CSA C22.2 No. 142
S200-IR8 A CSA C22.2 No. 142
S200-IRT8 A CSA C22.2 No. 142
S200-IT8 A CSA C22.2 No. 142
S200-OA8 A CSA C22.2 No. 142
S200-OA8I A CSA C22.2 No. 142
S200-OB16 A CSA C22.2 No. 142
S200-OB16P A CSA C22.2 No. 142
S200-OB8EP A CSA C22.2 No. 142
S200-OE4 A CSA C22.2 No. 142
S200-OE4 B CSA C22.2 No. 142
S200-OF4I A CSA C22.2 No. 142
S200-OW8 A CSA C22.2 No. 142
S200-RPA A CSA C22.2 No. 142
S200-RPA B CSA C22.2 No. 1010-92
S200-RPCD A CSA C22.2 No. 142
S200-RPFM A CSA C22.2 No. 142
S200-TB2 A CSA C22.2 No. 142
S200-TB3 A CSA C22.2 No. 142
S200-TB3G A CSA C22.2 No. 142
S200-TB3S A CSA C22.2 No. 142
S200-TB3T A CSA C22.2 No. 142
S200-TBN A CSA C22.2 No. 142
TC-CCN013 A CSA C22.2 No. 142
TC-CCN014 A CSA C22.2 No. 1010-92
TC-CCR013 A CSA C22.2 No. 142
TC-CCR014 A CSA C22.2 No. 1010-92
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 14 of 15
TC-CDN011 A CSA C22.2 No. 142
TC-CEN021 A CSA C22.2 No. 1010-92
TC-FCCN01 C CSA C22.2 No. 142
TC-FCCR01 C CSA C22.2 No. 142
TC-FIAH81 B CSA C22.2 No. 142
TC-FID161 A CSA C22.2 No. 142
TC-FIDA81 A CSA C22.2 No. 142
TC-FIL081 A CSA C22.2 No. 142
TC-FIR081 A CSA C22.2 No. 142
TC-FOA041 B CSA C22.2 No. 142
TC-FOD161 A CSA C22.2 No. 142
TC-FODA81 A CSA C22.2 No. 142
TC-FOR081 A CSA C22.2 No. 142
TC-FPCXX2 C CSA C22.2 No. 1010-92
TC-FPDXX2 C CSA C22.2 No. 1010-92
TC-FPDXX3 A CSA C22.2 No. 142
TC-FTB301 A CSA C22.2 No. 142
TC-FTB3T1 A CSA C22.2 No. 142
TC-FXX042 A CSA C22.2 No. 142
TC-FXX072 A CSA C22.2 No. 142
TC-FXX102 A CSA C22.2 No. 142
TC-FXX132 A CSA C22.2 No. 142
TC-FXX172 A CSA C22.2 No. 142
TC-IAH061 A CSA C22.2 No. 142
TC-IAH081 A CSA C22.2 No. 1010-92
TC-IAH161 A CSA C22.2 No. 1010-92
TC-IDA161 A CSA C22.2 No. 142
TC-IDD161 A CSA C22.2 No. 142
TC-IDD321 A CSA C22.2 No. 142
TC-IDD321 B CSA C22.2 No. 142
TC-IDJ161 A CSA C22.2 No. 142
TC-IDK161 A CSA C22.2 No. 142
TC-IDW161 A CSA C22.2 No. 142
TC-IDX081 A CSA C22.2 No. 142
TC-IDX161 A CSA C22.2 No. 142
TC-IXL061 A CSA C22.2 No. 142
TC-IXL062 A CSA C22.2 No. 1010-92
TC-IXR061 A CSA C22.2 No. 142
TC-OAH061 A CSA C22.2 No. 142
TC-OAV041 A CSA C22.2 No. 1010-92 After 2007-08
TC-OAV061 A CSA C22.2 No. 142
TC-OAV081 A CSA C22.2 No. 1010-92 After 2007-08
TC-ODA161 A CSA C22.2 No. 1010-92
TC-ODD161 A CSA C22.2 No. 1010-92
TC-ODD321 A CSA C22.2 No. 1010-92
TC-ODJ161 A CSA C22.2 No. 142
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 15 of 15
TC-ODK161 A CSA C22.2 No. 142
TC-ODX081 A CSA C22.2 No. 142
TC-ODX161 A CSA C22.2 No. 142
TC-ORC081 A CSA C22.2 No. 142
TC-ORC161 A CSA C22.2 No. 142
TC-PAL1C1 A CSA C22.2 No. 142
TC-PAM1B1 A CSA C22.2 No. 142
TC-PAS1A1 A CSA C22.2 No. 142
TC-PCIC01 A CSA C22.2 No. 142
TC-PCIC02 A CSA C22.2 No. 1010-92
TC-RPA001 A CSA C22.2 No. 142
TC-RPA002 A CSA C22.2 No. 1010-92
TC-RPCXX1 A CSA C22.2 No. 1010-92
TC-RPDXX1 A CSA C22.2 No. 1010-92
TC-RPFM01 A CSA C22.2 No. 142
TC-RPFS01 A CSA C22.2 No. 142
TC-RPSCA2 A CSA C22.2 No. 1010-92
TC-ZAL1C1 A CSA C22.2 No. 142
TC-ZAM1B1 A CSA C22.2 No. 142
/jj
http://directories.csa-international.org/xml_transform.asp?xml=certxml\069960_C_000-2258-02.xml&xsl=x... 5/9/2008
Page 1 of 1
Baldor Model X34M, Frame Sizes 48 and 56, Baldor Designation 410, 413, 416, 424 and 428 with Suffix L
denoting single phase or Suffix M denoting 3 ph, rated 3/4 hp max, 240V, 60Hz max, single phase or 1 hp max,
600V max, 3 ph, 60Hz, 3450 rpm max, with or without over temperature protection.
DC permanent magnet electric motors, Models 34, 35 and 36 frame sizes 56C, 143TC, 145TC. Rated 250V dc
max, 3500 rpm max, 3 hp max, duty rated or continuous, Class A or F insulation. Temperature Coded T3C, T3B,
T4, T4A, T5 or T6.
DC shunt wound or compound wound electric motors, Model 36, frame sizes 56C, 182A and 184AT. Rated 250V
dc max, 3500 Rpm, 2 hp max, continuous, Class A, B or F insulation. Temperature Coded T3C or T3B.
Model Frame Size 3500 rpm 2400 rpm 1750 rpm 1150 rpm
34 56C 1-1/2 1 3/4 1/2
35 143TC, 145TC 3 2 1-1/2 1
36 56C, 182A, 184AT - 2 2 1
/sh
http://directories.csa-international.org/xml_transform.asp?xml=certxml\063415_0_000-4228-01.xml&xsl=... 1/18/2007
Page 1 of
Certification Record
l Model C7061C/R8466 Combustible Gas Detection system consisting of C7061C sensors (1 or 2) mounted in the Hazardous Locations, and R8466
controller mounted in a non-hazardous area. Controller rated 24V dc (nominal), 120V or 240V ac, max 18W input. Output relay contacts rated 3A
(non-inductive) at 24V dc, or 120/240V ac.
Class I, Div. 1, Groups B, C, D; Class I, Zone 1, Group IIB+H2 (T5); Class II, Div. 1, Groups E, F, G; Class III; Class I, Div. 2, Groups A, B, C, D
(T4A); Class I, Zone 2, Group IIC (T4);
"Controller" Model EQ300X Series (Class I, Div. 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed in a suitable CSA
Certified labeled Type rated enclosure) rated 18-30 Vdc, 24 Vdc nom., 12 W max. input; relay contacts rated 1 Amp resistive at 30 Vdc; transformer
isolated digital communication I/O ports.
"Power Distribution Module" Model EQ3800 Series (Class I, Div. 2, Groups A, B, C, D (T3A); Class I, Zone 2, Group IIC (T3) only when installed in
a suitable CSA Certified labeled Type rated enclosure) rated 18-30 Vdc, 24 Vdc nom., 10 Amps max. per input; 27.5 Vdc nom. output voltage; 10 Amps
max. alarm output current; 2 Amps max. standby output current; reference manual for device specific output ratings.
"Power Supply" Model EQ2110PS, EQ2130PS and EQ2175PS (Ordinary Locations only) rated 120/208/240 Vac, 50/60 Hz. Model EQ2110PS rated 4
Amps at 120Vac input; 10 Amps at 24 Vdc output. Model EQ2130PS rated 11 / 6 / 6 Amps at 120 / 208 / 240 Vac input; 30 Amps at 24 Vdc output.
Model EQ2175PS rated 24 / 15 / 12 Amps at 120 / 208 / 240 Vac input; 75 Amps at 24 Vdc output.
"Power Supply Monitor" Model EQ2100PSM (Ordinary Locations only) rated 18-30 Vdc, 24 Vdc nom., 2 Watts max. input; 240 Vac max. and 75
Amps max. measurement range; transformer isolated digital communication input/output.
"Direct Current Input/Output" Model EQ3700 Series (Class I, Div. 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed in a
suitable CSA Certified labeled Type rated enclosure) rated 18-30 Vdc, 24 Vdc nom., 16.2 Amps input current; 18-30 Vdc output voltage; reference
manual for output current; relay contacts rated 2 Amps resistive at 30 Vdc.; transformer isolated digital communication status input/output.
"Initiating Device Circuit" Models EQ22xxIDC & EQ22xxIDCGF Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts max. input; dual digital inputs
(sealed or unsealed switch or relay contacts); transformer isolated digital communication input/output. The Models EQ22EMIDC & EQ22EMIDCGF
are rated Class I, Division 2, Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
"Ultraviolet Flame Detector" Model EQ22xxUV Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts max. input; transformer isolated digital communication
input/output.
"Ultraviolet and Infrared Flame Detector" Model EQ22xxUVIR Series rated 24 Vdc nom., 5 Watts max. input; transformer isolated digital
communication input/output.
"High Temperature Ultraviolet Flame Detector Module" Model EQ22xxUVHT Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts max. input, transformer
isolated digital communication input/output, pulsed input from a CSA Certified Model C7050B Series Ultraviolet Flame Detector.
"Triple Infrared Flame Detector" Model X3301xxx14 Series (Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G; Class III; Class I, Div.
2, Groups A, B, C, D (T3C); Class II, Div. 2, Groups F and G (T3C); Enclosure Type 4X) rated 18-32 Vdc, 24 Vdc nom., 12 Watts max. input;
transformer isolated digital communication input/output.
"Infrared Hydrocarbon Gas Detector" Model PIRECLx4 Series (Class I, Div. 1, Groups B, C, D (T4); Class I, Div. 2, Groups A, B, C, D (T4)) rated
18-32 Vdc, 24 Vdc nom., 10 Watts max. input; transformer isolated digital communication input/output. Provides output for HART Communication per
Drawing 007283-001. May be used with Model PIRTB Series PointWatch Termination Box.
"Digital Communication Unit" Model EQ22xxDCUEX Series rated 24 Vdc nom., 6 Watts max. input; transformer isolated digital communication
input/output. For use with Model CGS Series Combustible Gas Sensor and Model STB Sensor Termination Box. The Model EQ22EMDCUEX is rated
Class I, Division 2, Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
"Digital Communication Unit" Model EQ22xxDCU series rated 24 Vdc nom., 6 Watts max. input; 4-20mA input signal, transformer isolated digital
communication input/output. For use with CSA Certified 4-20 mA output devices. The Model EQ22EMDCU is rated Class I, Division 2, Groups A, B,
C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
"Network Extender" Model EQ24xxNE series rated 24 Vdc nom., 2.7 Watts max. input; transformer isolated digital communication input/output. The
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-01.xml&xsl=xsl/certrec.xsl 2/13/2007
Page 2 of
Model EQ24EMNE is rated Class I, Division 2, Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
"Agent Release Module" Model EQ25xxARM Series rated 18-30 Vdc, 24 Vdc nom., 75 mA standby, 120 mA alarm input; dual release outputs rated
30 Vdc max., 2 Amps max.; transformer isolated digital communication status input/output. The Model EQ25EMARM is rated Class I, Division 2,
Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
"Signal Audible Module" Model EQ25xxSAM Series rated 18-30 Vdc, 24 Vdc nom., 60 mA standby, 120 mA alarm input; dual outputs rated 30 Vdc
max., 2 Amps max.; transformer isolated digital communication status input/output. The Model EQ25EMSAM is rated Class I, Division 2, Groups A, B,
C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
"Explosionproof Enclosure Solution" Model EQ3900E Series (For EQ3900ExA Series: Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F,
G; Class III; Class I, Div. 2, Groups A, B, C, D (T5); Class II, Div. 2, Groups F and G (T5); Enclosure Type 4 only) (For EQ3900ExB Series: Class I,
Div. 1, Groups C and D; Class II, Div. 1, Groups E, F, G; Class III; Class I, Div. 2, Groups A, B, C, D (T5); Class II, Div. 2, Groups F and G (T5);
Enclosure Type 4 only) rated 18-30 Vdc, 24 Vdc nom., 37 Amps max. input.
"NEMA/Type N Enclosure Solution" Model EQ3900N Series (Class I, Div. 2, Groups A, B, C, and D (T3A); Class I, Zone 2, Group IIC (T3) only)
rated 18-30 Vdc, 24 Vdc nom., 53 Amps max. input.
"Relay Module" Model EQ3720 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed in a suitable CSA
Certified labeled Type rated enclosure) rated 18-30Vdc, 24V dc nom., 4W, max input; relay contacts rated 2 Amps resistive at 30V dc; transformer
isolated digital communication input/output.
"Ultraviolet Flame Detector" Model X2200xxx14 Series (Class I, Div 1, Groups B, C, D; Class II, Div 1, Groups E, F, G; Class III; Class I, Div 2,
Groups A, B, C, D (T3); Class II, Div 2, Groups F and G (T3); Enclosure Type (4X) rated 18-30Vdc, 24V dc nom., 2.5Watts to 7.6 Watts max. Input;
transformer insolated digital communication input/output.
"Infrared Flame Detector" Model X9800xxx14 Series (Class I, Div 1, Groups B, C, D; Class II, div 1 Groups E, F, G; Class III; Class I, Div 2, Groups
A, B, C, D (T3); Class II, Div 2, Groups F and G (T3); Enclosure Type (4X) rated 18-30Vdc, 24V dc nom., 2.1Watts to 16.5 Watts max. Input;
transformer insolated digital communication input/output
Ultraviolet/Infrared Flame Detector" Model X5200xxx14Series (Class I, Div 1, Groups B, C, D; Class II, Div 1, Groups E, F, G; Class III; Class I, Div
2, Groups A, B, C, D (T3); Class II, Div 2, Groups F and G (T3); Enclosure Type (4X) rated 18-30Vdc, 24V dc nom., 2.8Watts to 17.5 Watts max.
Input; transformer insolated digital communication input/output.
"Ground Fault Monitor" Model EQ2220 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed in a
suitable CSA Certified labeled type rated enclosure) rated 18-30V dc, 24V dc nom., 1W max input; relay contacts rated 1A resistive at 30V dc;
transformer isolated digital communication input/output.
"Analog Input Module" Model EQ3710 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed in a
suitable CSA Certified labeled type rated enclosure) rated 18-30V dc, 24V dc nom., 6W max input; 18-30V dc output voltage; reference manual for
output current; relay contacts rated 2A resistive at 30V dc; transformer isolated digital communication input/output. For use with CSA Certified 4-
20mA output devices.
"HART" Interface Module" Model HIM P/N 008056-001 (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when
installed in a suitable CSA Certified labeled type rated enclosure) rated 18-30V dc, 24V dc nom., 1W max input.
"Intelligent Protection Module" Model EQ3740 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed
in a suitable CSA Certified labeled type rated enclosure) rated 18-30V dc, 24V dc nom., 7W max input; relay contacts rated 2A resistive at 30V dc;
transformer isolated digital communication input/output.
"LON Termination Module" Model LTM P/N 008990-001 (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when
installed in a suitable CSA Certified labeled Type rated enclosure). For use with EQ300X Controller LON COM only.
"Relay Module" Model EQ3720 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed in a suitable CSA
Certified labeled Type rated enclosure) rated 18-30V dc, 24V dc nom, 4W max input; relay contacts rated 2A resistive at 30V dc and 0.5A resistive at
125V ac; transformer isolated digital communication input/output.
"Physical Layer Repeater" Model EQ24xxPLR Series rated 18-30V dc, 24V dc nom, 2.7W max input; transformer isolated digital communication
input/output. The Model EQ24EMPLR is rated Class I, Div 2, Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type
rated enclosure.
"Enhanced Discrete Input/Output" Model EQ3730 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC (T4) only when installed
in a suitable CSA Certified labeled Type rated enclosure) rated 18-30V dc, 24V dc nom, 16.2A input current; 18-30V dc output voltage; reference
manual for output current; relay contacts rated 2A resistive at 30V dc; transformer isolated digital communication input/output. For use with CSA
Certified relay contact output devices.
l "Infrared Hydrocarbon Gas Monitor" Model PIRDUCT Series (Class I, Div. I, Groups B, C, D; Class I, Div 2, Groups A, B, C, D (T3C) rated 18
32V dc, 24V dc nom, 7W max input. May be used with Model EQ22xxDCU Series Module.
Notes:
1. This system is for operation with a computer and software as covered in the instruction manual.
2. Reference drawing 007546-001 for applicable area classification and installation details.
Class I, Div. 1, Groups B, C and D; Class II, Div. 1, Groups E, F and G; Class III:
Class I, Div. 2, Groups A, B, C and D (T4A); Class II, Div. 2, Groups F and G (T4A); Enclosure Type 4X:
a. "Local Control Unit" Controller, Model EQ2100LCU (Class I, Div. 2, Groups A, B, C and D (T4A only) rated 18-30 vDC, 24 vDC, nom., 0.4
Amps max. input; relays rated 5 Amps resistive at 30 Vdc; transformer digital communication I/O ports. Model EQ2101LCU (Class I, Div. 2
Groups A, B, C and D (T4A only) rated 18-30 Vdc, 24 Vdc, nom., 12 Amps max., input; 2.8 Amps max. system output, 8.0 Amps max. auxiliary
output, relays rated 5 Amps resistive at 30 Vdc.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-01.xml&xsl=xsl/certrec.xsl 2/13/2007
Page 3 of
b. "Local Control Unit Power Supply" Model EQ2100LCUPS (Ordinary Locations only) rated 120/240V ac, 50/60Hz, 2.5A Amps max input; 8
Amps at 24 Vdc max. output; digital communication input/output. With auxiliary power supply, 1 Amp at 24 Vdc max. output each.
c. "Power Supply" Model EQ2110PS, EQ2130PS and EQ2175PS (Ordinary Locations only) rated 120/208/240 Vac, 50/60 Hz. Model EQ2110PS
rated 4 Amps at 120Vac input; 10 Amps at 24 Vdc output. Model EQ2130PS rated 11/6 / 6 Amps at 120 / 208 / 240 Vac input; 30 Amps at 24
Vdc output. Model EQ2175PS rated 24 / 15 / 12 Amps at 120 / 208 / 240 Vac input; 75 Amps at 24 Vdc output.
d. "Power Supply Monitor" Model EQ2100PSM (Ordinary Locations only) rated 18-30 Vdc, 24 Vdc nom., 2 Watts max. input; 240 Vac max. and 75
Amps max. measurement range; transformer isolated digital communication input/output.
e. "Local Input/Output Unit" Model EQ2100LIOU (Ordinary Locations only). rated 18-30 Vdc nom., 30 Watts max input. Relay module contacts
rated 2 Amps resistive at 24 Vdc. Signal audible module output rated 2 Amps at 24 Vdc; digital communication input/output. Release module
outputs rated 2 Amps at 24 Vdc max., supervisory current 2.5 mA each circuit.
f. "Agent Release Module" Model EQ25xxARM Series rated 18-30 Vdc, 24 Vdc nom., 75 mA standby, 120 mA alarm input; dual release outputs
rated 30 Vdc max., 2 Amps max.; transformer isolated digital communication status input/output. The Model EQ25EMARM is rated Class I,
Division 2, Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
g. "Signal Audible Module" Model EQ25xxSAM Series rated 18-30 Vdc, 24 Vdc nom., 60 mA standby, 120 mA alarm input; dual outputs rated 30
Vdc max., 2 Amps max.; transformer isolated digital communication status input/output. The Model EQ25EMSAM is rated Class I, Division 2,
Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
h. "Initiating Device Circuit" Model EQ22xxIDC and EQ22xxIDCGF Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts max. input; dual digital inputs
(sealed or unsealed switch or relay contacts); transformer isolated digital communication input/output. The Models EQ22EMIDC and
EQ22EMIDCGF are rated Class I, Division 2, Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated
enclosure.
i. "Ultraviolet Flame Detector" Model EQ22xxUV Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts max. input; transformer isolated digital
communication input/output.
j. "Ultraviolet and Infrared Frame Detector" Model EQ22xxUVIR Series rated 24 Vdc nom., 5 Watts max. input; transformer isolated digital
communication input/output.
k. "High Temperature Ultraviolet Flame Detector Module" Model EQ22xxUVHT Series rated 18-30V dc, 24V dc nom., 4 Watts max input,
transfomer isolated digital communication input/output, pulsed input from a CSA Certified Model C7050B Series Ultraviolet Flame Detector.
l. "Digital Communication Unit" EQ22xxDCUEX Series rated 24V dc nom., 6 Watts max. input; transformer isolated digital communication
input/output. For use with Model CGS Series Combustible Gas Sensors. The Model EQ22EMDCUEX is rated Class I, Division 2, Groups A, B,
C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
m. "Digital Communication Unit" EQ22xxDCU Series rated 24V dc nom., 6 Watts max. input; 4-20mA input signal, transformer isolated digital
communication input/output. For use with CSA Certified 4-20 mA output devices. The Model EQ22EMDCU is rated Class I, Division 2,
Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
n. "Network Extender" EQ24xxNE series rated 24 Vdc nom., 2.7 Watts max. input; transformer isolated digital communication input/output. The
Model EQ24EMNE is rated Class I, Division 2, Groups A, B, C and D :(T4A) when installed in a suitable CSA Certified labeled Type rated
enclosures.
o. Ultraviolet and Infrared Flame Detector" Model X5200xxx24 Series (Class I, Div 1, Groups B, C, D; Class II, Div I, Groups E, F, G; Class III,;
Class I, Div 2, Groups A, B, C, D (T3); Class II, Div 2, Groups F, and G (T3); Enclosure Type 4X) rated 18-30Vdc, 24V dc nom., 2.8Watts to
17.5 Watts max. Input; transformer insolated digital communication input/output
p. "Ultraviolet Flame Detector" Model X2200xxx24 Series (Class I, div 1, Groups B, C, D; Class II, Div 1, Groups E, F, g; Class III; Class I, Div 2,
Groups A, B, C, D (T3); Class II, Div 2, Groups F, and G(T3); Enclosure Type 4X) rated 18-30Vdc, 24V dc nom., 2.5Watts to 7.6 Watts max.
Input; transformer insolated digital communication input/output.
Notes:
1. "xx" suffixes denote type of enclosure material, thread type and number of threaded entries or electronic module intended for use with a suitable
CSA Certified type rated enclosure.
2. This system is for operation with a computer and software as covered in the instruction manual.
3. Reference drawing 006793-001 for applicable area classification and installation details.
4. The 000821-xxx and 00824-xxx Series utilizes a CSA Certified explosion-proof enclosure to house the EQ2101LCU and a limited number of field
devices.
l Infinit Gas Transmitter Model U9500A Series with enclosure P/N 006264-XXX, input rated 24V dc nom., 6.5W max; operating temperature -
40ºC to +75ºC, contacts rated 30V dc/5A (resistive); for use with Model CGS Series Combustible Gas Sensors. Infiniti Gas Transmitter Model
U9500H Series input rated 24V dc nom., 10.1W max; contacts rated 30V dc/5A (non-inductive); for use with any CSA Certified 4-20mA stand
alone gas detection instruments. Class II, Groups E, F and G; Class III; Enclosure Type 4X CSA Certified when used with Sensor Separation Kit
P/N 226365-106 and 226365-113.
Note: Reference Drawing 006880-001 for applicable area classification and installation details.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-01.xml&xsl=xsl/certrec.xsl 2/13/2007
Page 4 of
4X CSACertified when used with Sensor Separation Kit P/N 226365-106 or 226365-113.
(d) Communication Module" Type EA2300CM Series rated 24V dc nom., 60mA (without transmitter), relay rated 5.0A resistive at 30V dc.
Type EA2300CM2 Series rated 24V dc nom., 60mA (without transmitter), relay rated 1.0A resistive at 120V dc. For use with CSA Certified 4-20mA
devices.
(e) "Network Extender" Type EA2400NE Series rated 24V dc nom., 135mA, digital input/output. For in extending loop capacity up to a
maximum of 250 nodes and 10,000 metres of wiring. Class I, Div 2, Groups A, B, C and D (T4); Class II, Div 2 Groups F and G(T4); Class III;
Enclosure Type 4X.
(f) "Relay Module" Type EA2500RM Series rated 24V dc nom., 80mA, relay rated 5.0A resistive at 30V dc. Type EA2500RM2 Series rated
24V dc nom., 80mA, relay rated 1.0A resistive at 120V ac. For use with CSA Certified relay output devices.
Notes:
1. This sytem is for operation with a computer and software as covered in the instruction manual.
2. Reference drawing 006794-001 for applicable area classificaiton and installation details.
Class I, Groups B, C and D; Class I, Div 2, Groups A, B, C and D (T4A); Class II, Groups E, F and G; Class II, Div 2, Groups F and G; Class III;
Enclosure Type 4X:
l Sensor Termination Box (STB) 226365 Series input rated 36V dc max, 0.5W or reference CSA Component Certified terminal block rating.
Note: For proper installation, reference sensor for individual hazardous location classification.
Class I, Groups B, C and D; Class II, Groups E, F and G; Class III; Enclosure Type 4X:
l The Model 505 Series Combustible Gas Transmitter rated 24V dc nom., 4.0W max. For use with Model CGS Series Combustible Gas Sensors.
Class II, Groups E, F and G; Class III; Enclosure Type 4X CSA Certified when used with Sensor Separation Kit P/N 226365-118 through 226365
125.
Note: Reference Drawing 006816-001 for applicable area classification and installation details.
l Model 500 stand alone Combustible Gas Detection Transmitter; 17 to 28V dc; 1.5W (with sensor). For use with Model CGS Series Combustible
Gas Sensors and any CSA Certified 4-20mA controller. Class II, Groups E, F and G; Class III; Enclosure Type 4X CSA Certified when used with
Sensor Separation Kit P/N 226365-102, -114, -116, -117, -126, -128.
l Model 1K/2K/8K stand alone Combustible Gas Detection Transmitter; 10 to 33V dc; 1.5W (with sensor). For use with Model CGS Series
Combustible Gas Sensors and any CSA Certified 4-20mA controller. Class II, Groups E, F and G; Class III; Enclosure Type 4X CSA Certified
when used with Sensor Separation Kit P/N 226365-102, -114, -116, -117, -126, -128.
l Model DE3698/R8466 Combustible Gas Detection system consisting of 1 or 2 DE3698 detector head assemblies. Enclosure Detronics P/N
226555-103*. Mounted in the Hazardous Locations, and an R8466 controller mounted in a non-hazardous area. Controller rated 24V dc
(nominal), 120V or 240V ac, max 18W input. Output relay contacts rated 3A (non-inductive) at 24V dc, or 120/240V ac.
Notes:
1. Installation of panel and rack mounted assemblies are subject to the acceptance of the local inspection authorities.
2. The above instruments were also checked for performance and have been found to be acceptable as indicators of the presence of the flammable
gases and vapors within the scope of the certification when used in accordance with the manufacturer's instructions.
3. \Units are marked with "C22.2 No 152-M1984" located adjacent to CSA Monogram.
4. *When Red Dot enclosures P/N 226555-001, -004 for Models 500, 1k, 2k and P/N 226555-003 for Model DE3698 are used, suitable for Class I,
Groups C and D only.
Class I, Div 1, Groups B, C, and D; Class I, Div 2, Groups A, B, C and D; Enclosure Type 4X:
l "PointWatch Termination Box" gas detector junction box, Model PIRTB Series, input voltage 18 to 32V dc, 24V dc nom, 0.5W max, - 40 Deg C
to + 75 Deg C ambient temperature limits. May be used with PointWatch gas detectors, Models PIR9400, PIRVOL, and PIRECL Series.
l "Point Watch" stand alone combustible infrared (IR) gas detector, Model PIR9400 Series, input voltage 18 to 32 V dc, 24V dc nom., 7.0W max,
output 4-20mA. May be used with Point Watch termination box, Type PIRTB.
l "Duct Watch Gas Monitor" stand alone combustible infrared (IR) gas detector, Model PIRDUCT Series, input voltage 18 to 32V dc, 24V dc nom.,
7.0W max, output 4-20mA. May be used with Point Watch Termination Box, Model PIRTB Series.
Note: The XXX for Model 006414-XXX represents the variations in material type ( aluminum or stainless steel), thread type, cover style (short or tall
(with window) ) and number of conduit entries (2, 3, 4, 5, or 6).
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-01.xml&xsl=xsl/certrec.xsl 2/13/2007
Page 5 of
l Combustible Gas Sensor, Model CGS Series, input voltage 3.5V dc, 1.21W max. Performance verified from -40C to +75C ambient temperature
limits. Sensors must be used in conjunction with Detector Electronics Corporation gas transmitter Models 1K/2K/8K, 500, 505, U9500,
EA2200DCUEX or EQ2200DCUEX Series.
Note: The model CGS Series has been explosion proof verified from -55C to + 125C (T3C) ambient temperature limits.
Class I, Div 1, Groups B, C and D (T4); Class I, Div 2, Groups A, B, C and D(T4):
l "PointWatch Eclipse" stand alone infrared (IR) hydrocarbon gas detector, Model PIRECL Series, input voltage 18 to 32 V dc, 24V dc nom, 10W
max, output 4-20 mA , - 40 Deg C to + 75 Deg C ambient temperature limits. Provides output for HART Communication per Drawing 007283-
001. May be used with PointWatch Termination Box, model PIRTB Series.
Ordinary Locations:
l Model 1000 single channel stand alone Combustible Gas Detection Controller (Ordinary Locations); input rated 120V ac/24V dc/220V ac
nominal; 8.9W max; signal output 4-20mA. For use with any CSA Certified 4-20mA combustible gas detection instruments.
l Model 2000 dual channel stand alone Combustible Gas Detection Controller (Ordinary Locations); input rated 120V ac/24V dc/220V ac nominal;
15.7W max; signal output 4-20mA. For use with any CSA Certified 4-20mA combustible gas detection instruments.
l Model 8000 eight channel stand alone Combustible Gas Detection Controller (Ordinary Locations); input rated 120V ac/24V dc/220V ac nominal;
6.9W per channel max (120V ac); 5.8W per channel max (24V dc); signal output 4-20mA. For use with any CSA Certified 4-20mA combustible
gas detection instruments.
l Model R8471Axxxx single channel stand alone controller (Ordinary Locations), rack mount, input rated 24V dc nominal; 4.0W; signal 4-20mA;
relay contacts rated 250V ac/30V dc, 5A (resistive). For use with any CSA Certified 4-20mA combustible gas detection instruments.
Note: "xxxx" suffixes denote models with or without relays, mounting configuration and range configuration.
/mer
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-01.xml&xsl=xsl/certrec.xsl 2/13/2007
Page 1 of 7
Model C7064C hydrogen sulphide gas detector, rated 24V dc nom, 4-20mA, Temp. Code T4A, intrinsically safe
when connected to CSA Certified zener barriers, MTL728 or 787S or 788 or 705 or DetTronics Controllers Model
U8800 or U8810. For use with or without sensor separation kit Part No 226365-104 when installed per drawing
No. 6089-001.
Toxic gas detector controllers, Models 1100, 2100 and 8100, for use with submittor's sensors. Controllers mounted
outside the hazardous area. 1100 and 2100 are rated 120V, 60Hz; or 24V dc, 12W input. Output contacts rated
120V ac/24V dc, 10A. Model 8100 rated 120V ac, 60Hz, or 24V dc, 35W max. Alarm contacts rated 120V ac/30V
dc, 3A resistive.
Sensor/transmitter (CL2) Model C7067E, rated 24V dc nom., output rated 4-20mA. Intrinsically safe when
installed per drawing No 006160-001.
Class I, Div. 1, Groups B, C, D; Class I, Zone 1, Group IIB+H2 (T5); Class II, Div. 1, Groups E, F, G; Class III;
Class I, Div. 2, Groups A, B, C, D (T4A); Class I, Zone 2, Group IIC (T4);
Class II, Div. 2, Groups F and G (T4A); Enclosure Type 4X
- "Controller" Model EQ3000, EQ3001 or EQ3005 Series (Class I, Div. 2, Groups A, B, C, D (T4); Class I,
Zone 2, Group IIC (T4) only when installed in a suitable CSA Certified labeled Type rated enclosure) rated
18-30 Vdc, 24 Vdc nom., 12 W max. input; relay contacts rated 1 Amp resistive at 30 Vdc; transformer
isolated digital communication I/O ports.
- "Power Distribution Module" Model EQ3800 Series (Class I, Div. 2, Groups A, B, C, D (T3A); Class I,
Zone 2, Group IIC (T3) only when installed in a suitable CSA Certified labeled Type rated enclosure) rated
18-30 Vdc, 24 Vdc nom., 10 Amps max. per input; 27.5 Vdc nom. output voltage; 10 Amps max. alarm
output current; 2 Amps max. standby output current; reference manual for device specific output ratings.
- "Power Supply" Model EQ2110PS, EQ2130PS and EQ2175PS (Ordinary Locations only) rated
120/208/240 Vac, 50/60 Hz. Model EQ2110PS rated 4 Amps at 120Vac input; 10 Amps at 24 Vdc output.
Model EQ2130PS rated 11 / 6 / 6 Amps at 120 / 208 / 240 Vac input; 30 Amps at 24 Vdc output. Model
EQ2175PS rated 24 / 15 / 12 Amps at 120 / 208 / 240 Vac input; 75 Amps at 24 Vdc output.
- "Power Supply Monitor" Model EQ2100PSM (Ordinary Locations only) rated 18-30 Vdc, 24 Vdc nom., 2
Watts max. input; 240 Vac max. and 75 Amps max. measurement range; transformer isolated digital
communication input/output.
- "Direct Current Input/Output" Model EQ3700 Series (Class I, Div. 2, Groups A, B, C, D (T4); Class I,
Zone 2, Group IIC (T4) only when installed in a suitable CSA Certified labeled Type rated enclosure) rated
18-30 Vdc, 24 Vdc nom., 16.2 Amps input current; 18-30 Vdc output voltage; reference manual for output
current; relay contacts rated 2 Amps resistive at 30 Vdc.; transformer isolated digital communication status
input/output.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-02.xml&xsl=... 2/13/2007
Page 2 of 7
- "Initiating Device Circuit" Models EQ22xxIDC & EQ22xxIDCGF Series rated 18-30 Vdc, 24 Vdc nom., 4
Watts max. input; dual digital inputs (sealed or unsealed switch or relay contacts); transformer isolated
digital communication input/output. The Models EQ22EMIDC & EQ22EMIDCGF are rated Class I,
Division 2, Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated
enclosure.
- "Ultraviolet Flame Detector" Model EQ22xxUV Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts max. input;
transformer isolated digital communication input/output.
- "Ultraviolet and Infrared Flame Detector" Model EQ22xxUVIR Series rated 24 Vdc nom., 5 Watts max.
input; transformer isolated digital communication input/output.
- "High Temperature Ultraviolet Flame Detector Module" Model EQ22xxUVHT Series rated 18-30 Vdc, 24
Vdc nom., 4 Watts max. input, transformer isolated digital communication input/output, pulsed input from a
CSA Certified Model C7050B Series Ultraviolet Flame Detector.
- "Infrared Flame Detector" Model X3301xxx14 Series (Class I, Div. 1, Groups B, C, D; Class II, Div. 1,
Groups E, F, G; Class III; Class I, Div. 2, Groups A, B, C, D (T3C); Class II, Div. 2, Groups F and G (T3C);
Enclosure Type 4X) rated 18-32 Vdc, 24 Vdc nom., 12 Watts max. input; transformer isolated digital
communication input/output.
- "Digital Communication Unit" Model EQ22xxDCU series rated 24 Vdc nom., 6 Watts max. input; 4-
20mA input signal, transformer isolated digital communication input/output. For use with CSA Certified 4-
20 mA output devices. The Model EQ22EMDCU is rated Class I, Division 2, Groups A, B, C and D (T4A)
when installed in a suitable CSA Certified labeled Type rated enclosure.
- "Network Extender" Model EQ24xxNE series rated 24 Vdc nom., 2.7 Watts max. input; transformer
isolated digital communication input/output. The Model EQ24EMNE is rated Class I, Division 2, Groups A,
B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
- "Agent Release Module" Model EQ25xxARM Series rated 18-30 Vdc, 24 Vdc nom., 75 mA standby, 120
mA alarm input; dual release outputs rated 30 Vdc max., 2 Amps max.; transformer isolated digital
communication status input/output. The Model EQ25EMARM is rated Class I, Division 2, Groups A, B, C
and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
- "Signal Audible Module" Model EQ25xxSAM Series rated 18-30 Vdc, 24 Vdc nom., 60 mA standby, 120
mA alarm input; dual outputs rated 30 Vdc max., 2 Amps max.; transformer isolated digital communication
status input/output. The Model EQ25EMSAM is rated Class I, Division 2, Groups A, B, C and D (T4A)
when installed in a suitable CSA Certified labeled Type rated enclosure.
- "Explosionproof Enclosure Solution" Model EQ3900E Series (For EQ3900ExA Series: Class I, Div. 1,
Groups B, C, D; Class II, Div. 1, Groups E, F, G; Class III; Class I, Div. 2, Groups A, B, C, D (T5); Class II,
Div. 2, Groups F and G (T5); Enclosure Type 4 only) (For EQ3900ExB Series: Class I, Div. 1, Groups C
and D; Class II, Div. 1, Groups E, F, G; Class III; Class I, Div. 2, Groups A, B, C, D (T5); Class II, Div. 2,
Groups F and G (T5); Enclosure Type 4 only) rated 18-30 Vdc, 24 Vdc nom., 37 Amps max. input.
- "NEMA/Type N Enclosure Solution" Model EQ3900N Series (Class I, Div. 2, Groups A, B, C, and D
(T3A); Class I, Zone 2, Group IIC (T3) only) rated 18-30 Vdc, 24 Vdc nom., 53 Amps max. input.
- "Relay Module" Model EQ3720 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2, Group IIC
(T4) only when installed in a suitable CSA Certified labeled Type rated enclosure) rated 18-30Vdc, 24V dc
nom., 4W, max input; relay contacts rated 2 Amps resistive at 30V dc; transformer isolated digital
communication input/output.
- "Ultraviolet Flame Detector" Model X2200xxx14 Series (Class I, Div 1, Groups B, C, D; Class II, Div 1,
Groups E, F, G; Class III; Class I, Div 2, Groups A, B, C, D (T3); Class II, Div 2, Groups F and G (T3);
Enclosure Type (4X) rated 18-30Vdc, 24V dc nom., 2.5 Watts to 7.6 Watts max. Input; transformer
insolated digital communication input/output.
- "Infrared Flame Detector" Model X9800xxx14 Series (Class I, Div 1, Groups B, C, D; Class II, div 1
Groups E, F, G; Class III; Class I, Div 2, Groups A, B, C, D (T3); Class II, Div 2, Groups F and G (T3);
Enclosure Type (4X) rated 18-30Vdc, 24V dc nom., 2.1Watts to 16.5 Watts max. Input; transformer
insolated digital communication input/output.
- Ultraviolet/Infrared Flame Detector" Model X5200xxx14 Series (Class I, Div 1, Groups B, C, D; Class II,
Div 1, Groups E, F, G; Class III; Class I, Div 2, Groups A, B, C, D (T3); Class II, Div 2, Groups F and G
(T3); Enclosure Type (4X) rated 18-30Vdc, 24V dc nom., 2.8 Watts to 17.5 Watts max. Input; transformer
insolated digital communication input/output.
- "Ground Fault Monitor" Model EQ2220 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2,
Group IIC (T4) only when installed in a suitable CSA Certified labeled type rated enclosure) rated 18-30V
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-02.xml&xsl=... 2/13/2007
Page 3 of 7
dc, 24V dc nom., 1W max input; relay contacts rated 1A resistive at 30V dc; transformer isolated digital
communication input/output.
- "Analog Input Module" Model EQ3710 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I, Zone 2,
Group IIC (T4) only when installed in a suitable CSA Certified labeled type rated enclosure) rated 18-30V
dc, 24V dc nom., 6W max input; 18-30V dc output voltage; reference manual for output current; relay
contacts rated 2A resistive at 30V dc; transformer isolated digital communication input/output. For use with
CSA Certified 4-20mA output devices.
- "HART" Interface Module" Model HIM P/N 008056-001 (Class I, Div 2, Groups A, B, C, D (T4); Class
I, Zone 2, Group IIC (T4) only when installed in a suitable CSA Certified labeled type rated enclosure) rated
18-30V dc, 24V dc nom., 1W max input.
- "Intelligent Protection Module" Model EQ3740 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I,
Zone 2, Group IIC (T4) only when installed in a suitable CSA Certified labeled type rated enclosure) rated
18-30V dc, 24V dc nom., 7W max input; relay contacts rated 2A resistive at 30V dc; transformer isolated
digital communication input/output.
- "Enhanced Discrete Input/Output" Model EQ3730 Series (Class I, Div 2, Groups A, B, C, D (T4); Class I,
Zone 2, Group IIC (T4) only when installed in a suitable CSA Certified labeled Type rated enclosure) rated
18-30V dc, 24V dc nom, 16.2A input current; 18-30V dc output voltage; reference manual for output
current; relay contacts rated 2A resistive at 30V dc; transformer isolated digital communication
input/output. For use with CSA Certified relay contact output devices.
Notes:
1. This system is for operation with a computer and software as covered in the instruction manual.
2. Reference drawing 007546-001 for applicable area classification and installation details.
Class I, Groups B, C and D; Class II, Groups E, F and G; Class III; Enclosure Type 4X:
Class I, Div. 2, Groups A, B, C and D (T4A); Class II, Div. 2, Groups F and G (T4A); Enclosure Type 4X:
(a) "Commmunication Gateway" controller Type EA2100CG Series (Ordinary Locations) rack mounted, rated 24V dc
nom., 325mA (1.0A start-up), relays rated 5.0A resistive at 30V dc.
(b) "Digital Communication Unit" Type EA2200DCUUNIV Series rated 24V dc nom., 180mA (500mA start-up), relay
rated 5.0A resistive at 30V dc. For use with CSA Certified 4-20mA output devices. Class II, Div. 1, Groups E, F and G;
Class II, Div. 2, Groups F and G (T4A); Class III; Enclosure Type 4X CSA Certified when used with Sensor Separation
Kit P/N 226365-106 or 226365-113.
(d) "Communication Module" Type EA2300CM Series rated 24V dc nom., 60mA (without transmitter), relay rated
5.0A resistive at 30V dc. Type EA2300CM2 Series rated 24V dc nom., 60mA (without transmitter), relay rated 1.0A
resistive at 120V ac. For use with CSA Certified 4-20mA devices.
(e) "Network Extender" Type EA2400NE Series rated 24V dc nom., 135mA, digital input/output. For use in extending
loop capacity up to a maximum of 250 nodes and 10,000 metres of wiring. Class I, Div 2, Groups A, B, C and D (T4);
Class II, Div 2, Groups F and G (T4); Class III; enclosure Type 4X.
(f) "Relay Module: Type EA2500RM Series rated 24V dc nom., 80mA, relay rated 5.0A resistive at 30V dc. Type
EA2500RM2 Series rated 24V dc nom., 60mA (without transmitter), relay rated 1.0A resistive at 120V ac. For use with
CSA Certified relay output devices.
Notes:
1. This system is for operation with a computer and software as covered in the instruction manual.
2. Reference drawing 006794-001 for applicable area classification and installation details.
Class I, Div. 1, Groups B, C and D; Class II, Div. 1, Groups E, F and G; Class III:
Class I, Div. 2, Groups A, B, C and (T4A); Class II, Div. 2, Groups F and G (T4A); Enclosure Type 4X:
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-02.xml&xsl=... 2/13/2007
Page 4 of 7
1. "Local Control Unit" Controller, Model EQ2100LCU and EQ2101LCU (Class I, Div. 2, Groups A, B, C and D
(T4A only) rated 18-30 vDC, 24 vDC, nom., 0.4 Amps max. input; relays rated 5 Amps resistive at 30 Vdc;
transformer digital communication I/O ports. Model EQ2101LCU (Class I, Div. 2 Groups A, B, C and D (T4A
only) rated 18-30 Vdc, 24 Vdc, nom., 12 Amps max., input; 2.8 Amps max. system output, 8.0 Amps max.
auxiliary output, relays rated 5 Amps resistive at 30 Vdc.
2. "Local Control Unit Power Supply" Model EQ2100LCUPS (Ordinary Locations only) rated 120/240V ac,
50/60Hz, 2.5A Amps max input; 8 Amps at 24 Vdc max. output; digital communication input/output. With
auxiliary power supply, 1 Amp at 24 Vdc max. output each.
3. "Power Supply" Model EQ2110PS, EQ2130PS and EQ2175PS (Ordinary Locations only) rated 120/208/240 Vac,
50/60 Hz. Model EQ2110PS rated 4 Amps at 120Vac input; 10 Amps at 24 Vdc output. Model EQ2130PS rated
11/6 / 6 Amps at 120 / 208 / 240 Vac input; 30 Amps at 24 Vdc output. Model EQ2175PS rated 24 / 15 / 12 Amps
at 120 / 208 / 240 Vac input; 75 Amps at 24 Vdc output.
4. "Power Supply Monitor" Model EQ2100PSM (Ordinary Locations only) rated 18-30 Vdc, 24 Vdc nom., 2 Watts
max. input; 240 Vac max. and 75 Amps max. measurement range; transformer isolated digital communication
input/output.
5. "Local Input/Output Unit" Model EQ2100LIOU (Ordinary Locations only). rated 18-30 Vdc nom., 30 Watts max
input. Relay module contacts rated 2 Amps resistive at 24 Vdc. Signal audible module output rated 2 Amps at 24
Vdc; digital communication input/output. Release module outputs rated 2 Amps at 24 Vdc max., supervisory
current 2.5 mA each circuit.
6. "Agent Release Module" Model EQ25xxARM Series rated 18-30 Vdc, 24 Vdc nom., 75 mA standby, 120 mA
alarm input; dual release outputs rated 30 Vdc max., 2 Amps max.; transformer isolated digital communication
status input/output. The Model EQ25EMARM is rated Class I, Division 2, Groups A, B, C and D (T4A) when
installed in a suitable CSA Certified labeled Type rated enclosure.
7. "Signal Audible Module" Model EQ25xxSAM Series rated 18-30 Vdc, 24 Vdc nom., 60 mA standby, 120 mA
alarm input; dual outputs rated 30 Vdc max., 2 Amps max.; transformer isolated digital communication status
input/output. The Model EQ25EMSAM is rated Class I, Division 2, Groups A, B, C and D (T4A) when installed
in a suitable CSA Certified labeled Type rated enclosure.
8. "Initiating Device Circuit" Model EQ22xxIDC and EQ22xxIDCGF Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts
max. input; dual digital inputs (sealed or unsealed switch or relay contacts); transformer isolated digital
communication input/output. The Models EQ22EMIDC and EQ22EMIDCGF are rated Class I, Division 2,
Groups A, B, C and D (T4A) when installed in a suitable CSA Certified labeled Type rated enclosure.
9. "Ultraviolet Flame Detector" Model EQ22xxUV Series rated 18-30 Vdc, 24 Vdc nom., 4 Watts max. input;
transformer isolated digital communication input/output.
10. "Ultraviolet and Infrared Frame Detector" Model EQ22xxUVIR Series rated 24 Vdc nom., 5 Watts max. input;
transformer isolated digital communication input/output.
11. "High Temperature Ultraviolet Flame Detector Module" Model EQ22xxUVHT Series rated 18-30V dc, 24V dc
nom., 4 Watts max. input, transformer isolated digital communication input/output, pulsed input from a CSA
Certified Model C7050B Series Ultraviolet Flame Detector.
12. "Digital Communication Unit" EQ22xxDCU Series rated 24V dc nom., 6 Watts max. input; 4-20mA input signal,
transformer isolated digital communication input/output. For use with CSA Certified 4-20 mA output devices.
The Model EQ22EMDCU is rated Class I, Division 2, Groups A, B, C and D (T4A) when installed in a suitable
CSA Certified labeled Type rated enclosure.
13. "Network Extender" EQ24xxNE series rated 24 Vdc nom., 2.7 Watts max. input; transformer isolated digital
communication input/output. The Model EQ24EMNE is rated Class I, Division 2, Groups A, B, C and D :(T4A)
when installed in a suitable CSA Certified labeled Type rated enclosures.
14. Ultraviolet and Infrared Flame Detector" Model X5200xxx24 Series (Class I, Div 1, Groups B, C, D; Class II, Div
I, Groups E, F, G; Class III,; Class I, Div 2, Groups A, B, C, D (T3); Class II, Div 2, Groups F, and G (T3);
Enclosure Type 4X) rated 18-30Vdc, 24V dc nom., 2.8Watts to 17.5 Watts max. Input; transformer insolated
digital communication input/output
15. "Ultraviolet Flame Detector" Model X2200xxx24 Series (Class I, div 1, Groups B, C, D; Class II, Div 1, Groups
E, F, g; Class III; Class I, Div 2, Groups A, B, C, D (T3); Class II, Div 2, Groups F, and G(T3); Enclosure Type
4X) rated 18-30Vdc, 24V dc nom., 2.5Watts to 7.6 Watts max. Input; transformer insolated digital communication
input/output
Notes:
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-02.xml&xsl=... 2/13/2007
Page 5 of 7
1. "xx" suffixes denote type of enclosure material, thread type and number of threaded entries or electronic module
intended for use with a suitable CSA Certified type rated enclosure.
2. This system is for operation with a computer and software as covered in the instruction manual.
3. Reference drawing 006793-001 for applicable area classification and installation details.
4. The 000821-xxx and 00824-xxx Series utilizes a CSA Certified explosion-proof enclosure to house the
EQ2101LCU and a limited number of field devices.
Infiniti Gas Transmitter Models U9500B20 Series, U9500C Series, U9500D Series, U9500E Series, U9500F
Series and U9500G Series, with enclosure P/N 006264-XXX, input rated 24V dc nom., 5.0W max; operating
temperature -40ºC to +75ºC, contacts rated 30V dc/5A (resistive); for use with any Certified 4-20mA stand alone
gas detection instruments. Class II, Groups E, F and G; Class III; Enclosure Type 4X CSA Certified when used
with Sensor Separation Kit P/N 226365-104 and 226365-111.
Note: Reference Drawing 006880-001 for applicable area classification and installation details.
Infiniti Gas Transmitter Models U9500B21 Series with enclosure P/N 006264-XXX, input rated 24V dc nom.,
6.5W max; operating temperature -40ºC to +75ºC, contacts rated 30V dc/5A (resistive); for use with Type 225629
MOS Hydrogen Sulfide Gas Sensor. Class II, Groups E, F and G; Class III; Enclosure Type 4X CSA Certified
when used with Sensor Separation Kit P/N 226365-104 and 226365-111.
Note: Reference Drawing 006880-001 for applicable area classification and installation details.
Class I, Groups B,C and D; Class I, Div 2, Groups A,B,C and D (T4A); Class II, Groups E, F and G; Class II, Div 2,
Groups F and G; Class III; Enclosure Type 4X:
Sensor Termination Box (STB) 226365 Series input rated 36V dc max, 0.5W or reference CSA Component
Certified terminal block rating.
Note: For proper installation, reference sensor for individual hazardous location classification.
Model U8800 H2S toxic gas controller/transmitter (explosion-proof), CSA Encl 4, rated 24V dc nom., 150mA;
signal 4-20mA; relay contacts 30V dc, 5A; provides intrinsically safe output for connection to Model C7064C
hydrogen sulphide gas detector. May be used with sensor separation kit Part No 226365-104 when installed per
drawing No. 6089-001.
Model U8810 H2S toxic gas controller/transmitter (explosion-proof), CSA Encl 4, rated 24V dc-50mA, signal 4-
20mA; provides intrinsically safe output for connection to Model C7064C H2S gas detector. May be used with
sensor separation kit Part No 226365-104 when installed per drawing No. 6089-001.
Model 415 N2S transmitter, CSA Encl. 4; input rated 24V dc-4W. May be used with sensor separation kit Part No
226365-107.
Series Infiniti toxic gas detector/controller, Models U9500 XXXXX, input rated 24V dc nom, 7.7W; contacts rated
30V dc/5A resistive. For use with sensors Models C7064C and C7067E. May be used with sensor separation kit
Part No 226365-104.
Note: XXXXX suffixes denote type of toxic sensor and models with or without relays.
Sensor/Transmitter Model C7064E5014 (H2S) input rated 24V dc nominal, output rated 4-20mA.
Note: These devices are Certified only for electrical safety and use in hazardous locations. Hazardous location testing
has been successfully completed on Model C7064E5014 from an ambient temperature range of -40°C to +75°C;
however, the detector label marking indicates -40°C to +50°C.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-02.xml&xsl=... 2/13/2007
Page 6 of 7
Class I, Div. 1, Groups C and D; Class I, Div. 2, Groups A, B, C and D (T4A):
Sensor/Transmitters Model C7064E Series (H2S), Model C7065E Series (O2), Model C7066E Series (CO), Model
C7068E Series (SO2), and Model C7069E Series (NO2) input rated 24V dc nominal, output rated 4-20mA.
Note: These devices are Certified only for electrical safety and use in hazardous locations. Hazardous location testing
has been successfully completed on the Model C7064E Series from an ambient temperature range of -40°C to +75°C;
however, the detector label marking indicates -40°C to +50°C.
Fixed hydrogen sulphide gas detection system, Model 710 comprising of the following: A control station, panel or
rack-mounted type with single or multi (6 max) plug-in module rack/frames, 120/240V ac, 60Hz or 12.5V dc,
10W (each plug-in module), alarm contact rating 120V ac, 60hz or 30V dc, 3A resistive, for installation in an
ordinary (non-hazardous) location, and remote detector head(s), Type 226115, for use in hazardous locations.
Fixed hydrogen sulphide gas detection system, Model 740 comprising of the following: A control station, panel or
rack-mounted type with single or multi (4 max), plug-in module rack frames (controller), 120V ac, 60Hz and/or
24V dc, 15W (each plug-in module), alarm contact rating 120V ac, 60Hz or 30V dc, 3A resistive, for installation
in non-hazardous locations, and a remote detector head(s), Model 704 enclosure P/N 225690-001 or P/N 225693-
102 for use in hazardous locations.
Notes:
1. Installation of panel and rack-mounted assemblies are subject to the acceptance of the local inspection authorities
having jurisdiction.
2. The above toxic gas detection system(s) are Certified for electrical safety and for use in hazardous locations only,
and not for performance.
Model 410, H2S Detector, CSA Encl. 4 input rated 24V dc, 4W; for use with P/N 225629 sensors.
Ordinary Locations:
Model R8471Bxxxx single channel controller (H2S) (Ordinary Locations), rack mount, input rated 24V dc nom.,
4.0W; signal 4-20mA; relay contacts rated 250V ac/30V dc, 5A (resistive). For use with any CSA Certified 4-
20mA H2S gas detection instruments.
Model R8471Cxxxx single channel controller (O2) (Ordinary Locations), rack mount, input rated 24V dc nom.,
4.0W; signal 4-20mA; relay contacts rated 250V ac/30V dc, 5A (resistive). For use with any CSA Certified 4-
20mA O2 gas detection instruments.
Model R8471Dxxxx single channel controle (CL2) (Ordinary Locations), rack mount, input rated 24V dc nom.,
4.0W; signal 4-20mA; relay contacts rated 250V ac/30V dc, 5A (resistive). For use with any CSA Certified 4-
20mA CL2 gas detection instruments.
Model R8471Exxxx single channel controller (CO) (Ordinary Locations), rack mount, input rated 24V dc nom.,
4.0W; signal 4-20mA; relay contacts rated 250V ac/30V dc, 5A (resistive). For use with any CSA Certified 4-
20mA CO gas detection instruments.
Model R8471Fxxxx single channel controller (SO2) (Ordinary Locations), rack mount, input rated 24V dc nom.,
4.0W; signal 4-20mA; relay contacts rated 250V ac/30V dc, 5A (resistive). For use with any CSA Certified 4-
20mA SO2 gas detection instruments.
Model R8471Gxxxx single channel controller (NO2) (Ordinary Locations), rack mount, input rated 24V dc nom.,
4.0W; signal 4-20mA; relay contacts rated 250V ac/30V dc, 5A (resistive). For use with any CSA Certified 4-
20mA NO2 gas detection instruments.
Note: "xxxx" suffixes denote models with or without relays, mounting configuration and range configuration.
MOS Hydrogen Sulfide Gas Sensor, Type 225629 Series, input voltage 4.5V dc maximum, 0.8W maximum.
Sensors -001 through -004 must be used in conjunction with Detector Electronics Corporation gas transmitter
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-02.xml&xsl=... 2/13/2007
Page 7 of 7
Models 410. Sensors -007, -008, - 009 and -010 must be used in conjunction with Detector Electronics
Corporation gas transmitter U9500B21 Series.
/mer
http://directories.csa-international.org/xml_transform.asp?xml=certxml\052532_C_000-4828-02.xml&xsl=... 2/13/2007
Page 1 of 2
Certification Record
Series A - Pneumatic or hydraulic service, pilot operated, 4-way with suffix "XX" max pressure 200 psi pneumatic, 300 psi hydraulic.
Series B - Pneumatic service only, pilot operated, 2 and 3-way with suffix "XX" max pressure 200 psi.
Series E - Pneumatic or hydraulic service, direct solenoid operated; 2 and 3-way directional and multi-directional. With suffix "XX"
max pressure 250 psi
Series K - Pneumatic service only, pilot operated, 2, 3, 4 or 5-way, 2, 3, 4 or 8 position. Suffix "XX" max pressure 175 psi.
Series M - Pneumatic service pilot operated, 2-way. Suffix "XX" max pressure 200 psi.
Series T - Hydraulic service only, pilot operated, 2, 3, 4, 5, 7 or 8-way. Suffix "XX" max pressure 500 psi
Series V - Pneumatic service only, 2, 3, 4, 5, 7 or 8-way. Suffix "XX" max pressure 200 psi
Series V(316)- Pneumatic service only, 3, 4, 5, 7 or 8-way. Suffix "XX" max pressure 200 psi.
Suffix "XX" rated 480 ac, 60Hz max, 120V dc max 12W max for Series 20 solenoid operators and rated 480V ac max, 50/60Hz, 5.6W
max, 6 to 250V ac 7.2W max for Series 50 solenoid operators.
Notes:
1. Prefix letters and numbers added to the valve series designation indicates valve type, port sizes, body and flow patterns etc
2. Additional suffix detail designations PC and PS, G5R, M, M5R, 3, B, ST, G, FS, HT and N indicate options on valve assemblies.
3. The additional suffix letters and/or numbers indicate minor external mechanical variation
4. All valves are Certified as component parts for use in other equipment where the suitability of the combination is to be determined
by CSA International
5. Series V(316) uses operators V0E51 through 56 only.
l Solenoid valve operators, 480V and less, 50/60Hz, 7.3W; 120V dc and less, 9.5W; Models VOE21, VOE22, VOEH22, VOE23,
VOE24, VOE25 and VOE26 with suffix letter CC followed by letter F, H, M, P or V with or without suffix letter B, with or
without additional suffix letters. Models VOE21, VOE22, VOEH22, VOE23, VOE24, VOE25 and VOE26 followed by letter Z
with a five digit number suffix followed by letters CC followed by letter F, H, M, P or V.
l Solenoid operators, Models VOE51, VOE52, VOE53, VOE54, VOE55 and VOE56, followed by letters CC, followed by letters
B, M or P, rated 12 to 480V, 50/60Hz, 5.6W max, 6 to 250V dc, 7.2W max.
l Solenoid operators, rated 12 to 240V, 60Hz, 1.8W, 5 to 120V dc, 1.8W:
Models VOEL51, VOEL52 and VOEL53 followed by letters C or CC, followed by letters B, H, M or P.
Models VOEL51, VOEL52 and VOEL53 followed by letter Z with a five digit number suffix, followed by letters CB, CH, CM
CP, CCB, CCH, CCM or CCP.
Notes:
1. All solenoid operators Series 20 and 50 are certified for use in other equipment where the suitability of the combination is to be
determined by CSA International.
2. Additional suffix detail designation for Series 20 and 50 solenoid operators: FS, PS, PC, HT, 3, ST, N.
Class I, Div 1, Groups C and D; Class II, Div 1, Groups E, F and G; Temperature Code T6; Type 4X and 6P:
Class I, Div 2, Groups C and D; Class II, Div 2, Groups E, F and G; Type 4X and 6P:
l Series E3SM-I-88-316-II-III-IV Solenoid Operated Valves for general purposes, supply input rated 24 VDC, 1.86 Watts or
12VDC, 0.85 Watt, Maximum Working Pressure 125 PSI, Factory Sealed, -20°C to +49°C ambient.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\045277_0_000-3228-01.xml&xsl=xsl/certrec.xsl 3/30/2006
Page 2 of 2
/gl
http://directories.csa-international.org/xml_transform.asp?xml=certxml\045277_0_000-3228-01.xml&xsl=xsl/certrec.xsl 3/30/2006
Page 1 of 2
Class Description
COVERAGE:
Electrically operated general purpose valves and safety valves intended for use in hazardous locations for the control of fluids (e.g. air,
gases, oils, refrigerants, steam, water) and rated 600 volts and less. Valves intended for use in other equipment are subject to additional
investigation with the equipment.
REQUIREMENTS:
The certified equipment appearing in this classification is judged to comply with the applicable requirements of the NFPA 70 National
Electrical Code (NEC), for use in hazardous locations.
MARKING:
l submittor's identification;
l model designation or equivalent;
l suitable words, numerals or symbols to identify a safety valve;
l maximum operating pressure differential rating, type of fluid, intended direction of flow;
l complete electrical rating;
l applicable hazardous locations designation;
l time rating if not continuous;
l cautions, warnings and additional markings as may be required;
l CSA Monogram.
In addition, equipment intended for display, sale or use in the USA, is required to include other information such as warning statements,
installation instructions, etc., as may be specified in the NEC.
/mkc
http://directories.csa-international.org/xml_transform.asp?xml=classxml/3228-01.xml&xsl=xsl/class.xsl 3/30/2006
Page 2 of 2
http://directories.csa-international.org/xml_transform.asp?xml=classxml/3228-01.xml&xsl=xsl/class.xsl 3/30/2006
Page 1 of 3
Certification Record
Class I, Group D:
l Model VG-2.0, with cast aluminum or stainless steel body, rated 30Vdc max 100W
- P/N 5001892, Temp Code T3A for use in 93ºC ambient.
l Fuel Metering Valve for Gas Turbines, Model VG2.0, rated 30Vdc max, 100W, or 50W
- P/N 71800317-X, Temp Code T3A for use in 93ºC ambient.
Note: Suffix numbers following the basic model designation denote calibrated fuel flow and designated supply pressure;
suffix letter after "G" denotes body material.
l Liquid Fuel Metering Valve for Gas Turbines, Model VL10000EP Series, rated 30V dc max, 25W max; Temp
Code T4, for use in 93°C max ambient.
Note: Suffix numbers to the "VL" designation denote fuel flow in pounds per hour. Valve is calibrated for suffix
numbers ranging from 8000 to 24000 inclusive.
l Fuel Metering Valve for Gas Turbines, Model VG-1.5; rated 30 Vdc max, 25 W max.
- P/N 5000812-X, Temp Code T4 for use in 82°C ambient.
- P/N 5001584-X, Temp Code T4 for use in 93°C ambient.
- P/N 5001945-X, Temp Code T4 for use in 93°C ambient.
- P/N 5001998-X, Temp Code T4 for use in 93°C ambient.
l Fuel Metering Valve for Gas Turbines, VL Series, rated 30V dc max, 25W max.
- P/N 5002006-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002421-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002220-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002433-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002456-X, Temp Code T4 for use in 93°C ambient.
l Fuel Metering Valve for Gas Turbines, VL Series, rated 30V dc max, 25W max.
- P/N 5002007-X, Temp Code T4 for use in 93°C ambient.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\043366_0_000-3228-01.xml&xsl=xs... 1/7/2008
Page 2 of 3
- P/N 5002450-X, Temp Code T4 for use in 93°C ambient.
l Servo-Electronic Controller, Model SEC25, 120 Vdc, 800 W Max, Operating Temperature Ambient -40ºC to
+93ºC.
l Electric Actuator, Model ACT 2100-XXXXP, 120 Vdc, 800 W Max, Operating Temperature Ambient -40ºC to
+150ºC.
l Electric Actuator, Model ACT2000-XXXXP, 120 Vdc, 800 W Max, Operating Temperature Ambient -40°C to
+93°C.
- Part Number 5002300-X
- Part Number 5002600-X.
l Electric Actuator, Model ACT2000-XXXXF, 120 Vdc, 800 W Max, Operating Temperature Ambient -40ºC to
+93ºC.
- Part Number 5002375-X.
- Part Number 5002601-X
l "High Force" Fuel Metering Valve, Model HFG 2.0 - XXXX, 120 Vdc, 800 W Max, Operating Temperature
Ambient -40ºC to +93ºC.
-Part Number 5002400-X (Aluminum)
-Part Number 5002415-X (Stainless Steel).
-Part Number 5002605-X (Aluminum)
-Part Number 5002610-X (Stainless Steel)
-Part Number 5002447-X (Stainless Steel or Aluminum)
l "Component Assembly", FMV 24V SMT pcb for use as an alternate pcb in CSA Certified Precision Engine
Control Fuel Metering Valves as listed below.
The following products are approved to use either the 5001814-001 (through hole) PCB or the 5002359-001 SMT
PCB. The two models are electrically identical. The only difference is in the construction where one utilizes
through hole and the other uses surface mount technology.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\043366_0_000-3228-01.xml&xsl=xs... 1/7/2008
Page 3 of 3
5002220-x
5002433-x
VL Series 5002007-x 1105081 Class I, Division 2, Groups A, B, C and D
5002450-x (LR 43366-1)
VG2.0 71800317-x LR 43366-2 Class I, Group D
5001892-x
VL10000EP LR 43366-4 Class I, Group D
Class I, Division 1, Groups B, C and D; T4 (Tamb = -40°C to +93°C); CSA Encl Type 4:
/gp
http://directories.csa-international.org/xml_transform.asp?xml=certxml\043366_0_000-3228-01.xml&xsl=xs... 1/7/2008
Page 1 of 3
Certification Record
l Liquid Fuel Metering Valve for Gas Turbines, Model VL10000EP Series, rated 30V dc max, 25W max; Temp
Code T4, for use in 93°C max ambient.
Note: Suffix numbers to the "VL" designation denote fuel flow in pounds per hour. Valve is calibrated for suffix
numbers ranging from 8000 to 24000 inclusive.
l Fuel Metering Valve for Gas Turbines, Model VG-1.5; rated 30 Vdc max, 25 W max.
- P/N 5000812-X, Temp Code T4 for use in 82°C ambient.
- P/N 5001584-X, Temp Code T4 for use in 93°C ambient.
- P/N 5001945-X, Temp Code T4 for use in 93°C ambient.
- P/N 5001998-X, Temp Code T4 for use in 93°C ambient.
l Fuel Metering Valve for Gas Turbines, VL Series, rated 30V dc max, 25W max.
- P/N 5002006-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002421-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002220-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002433-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002456-X, Temp Code T4 for use in 93°C ambient.
l Fuel Metering Valve for Gas Turbines, VL Series, rated 30V dc max, 25W max.
- P/N 5002007-X, Temp Code T4 for use in 93°C ambient.
- P/N 5002450-X, Temp Code T4 for use in 93°C ambient.
l Servo-Electronic Controller, Model SEC25, 120 Vdc, 800 W Max, Operating Temperature Ambient -40ºC to
+93ºC.
- Part Number 5003222-XXX
- Part Number 5003218-XXX (Power harness)
- Part Number 5003219-XXX (control harness)
http://directories.csa-international.org/xml_transform.asp?xml=certxml\043366_0_000-3228-81.xml&xsl=xs... 1/7/2008
Page 2 of 3
l Electric Actuator, Model ACT 2100-XXXXP, 120 Vdc, 800 W Max, Operating Temperature Ambient -40ºC to
+150ºC.
- Part Number 5003221-XXX
- Part Number 5003218-XXX (Power harness)
- Part Number 5003219-XXX (control harness)
l Electric Actuator, Model ACT2000-XXXXP, 120 Vdc, 800 W Max, Operating Temperature Ambient -40°C to
+93°C.
- Part Number 5002300-X
- Part Number 5002600-X.
l Electric Actuator, Model ACT2000-XXXXF, 120 Vdc, 800 W Max, Operating Temperature Ambient -40ºC to
+93ºC.
- Part Number 5002375-X.
- Part Number 5002601-X
l "High Force" Fuel Metering Valve, Model HFG 2.0 - XXXX, 120 Vdc, 800 W Max, Operating Temperature
Ambient -40ºC to +93ºC.
-Part Number 5002400-X (Aluminum)
-Part Number 5002415-X (Stainless Steel).
-Part Number 5002605-X (Aluminum)
-Part Number 5002610-X (Stainless Steel)
-Part Number 5002447-X (Stainless Steel or Aluminum)
l "Component Assembly", FMV 24V SMT pcb for use as an alternate pcb in CSA Certified Precision Engine
Control Fuel Metering Valves as listed below.
The following products are approved to use either the 5001814-001 (through hole) PCB or the 5002359-001 SMT
PCB. The two models are electrically identical. The only difference is in the construction where one utilizes
through hole and the other uses surface mount technology.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\043366_0_000-3228-81.xml&xsl=xs... 1/7/2008
Page 3 of 3
Class I, Division 1, Groups B, C and D; T4 (Tamb = -40°C to +93°C); CSA Encl Type 4:
/gp
http://directories.csa-international.org/xml_transform.asp?xml=certxml\043366_0_000-3228-81.xml&xsl=xs... 1/7/2008
Page 1 of 1
Certification Record
l Pressure-operated switches, Cat Nos 1950 (weatherproof Encl. 3), 1951 and 1952, with suffixes*, rated 10A or 15A, 125, 250 or
480V ac, 1/8 hp, 125V ac, 1/4 hp, 250V ac, or 1A, 125V ac.
*Suffix numbers and letters are added to the catalogue designation to indicate pressure range, switch type, and minor mechanical
features.
l Pressure operated switches Cat No 1950G, with input rating of 12Vdc/ 1.1 W; 24Vdc/ 3W; 24Vac/ 6W; 120Vac/ 4W; 240Vac/
11W; with suffixes indicating pressure ranges, switch type and relay contact electrical ratings.
/ka
http://directories.csa-international.org/xml_transform.asp?xml=certxml\042749_0_000-3238-01.xml&xsl=xsl/certrec.xsl 5/5/2006
Page 1 of 1
Certification Record
Vehicles
l Fluorescent, surface mounted, for rapid start lamps, Cat Nos 199, 179, for 1-6WT5 lamp; 101, 111, 141, *161,
171, 191, for 1-8WT5 lamp; 112, 130, *162, 172, 180, for 2-8WT5 lamps; 125, 173, for 1-13WT5 lamp, 126, 174,
for 2-13WT5 lamps; 103, 115, 143, 193, for 1-15WT8 lamp; 116, 134, 190, for 2-15WT8 lamps; 105, 145, 195 for
1-18WT8 lamp; 151, for 1-20WT12 lamp, 107, 147, 197, for 1-30WT8 lamp; 153, for 1-40WT12 lamp; 109, for
1-22W circline lamp; 110, for 1-32W circline lamp, P293 for 1-15W/T8 lamp; Cat Nos 941, 943, for 5-8 W lamp;
945, 947, 949, for PL7-13 W lamp; 951, for PL18 W lamp; 953 for PL24-30 W lampl 957, 958 or PL32-40 W
lamp.
l Fluorescent, recessed types, for rapid-start lamps, Cat Nos 711, for 1-8WT5 lamp; 712, 732, for 2-8WT5 lamps;
715, for 1-15WT8 lamp; 716, 736, for 2-15WT8 lamps; 713, for 1-20WT12 lamp; 714, for 2-20WT12 lamps; 717,
for 1-30WT8 lamp; 718, for 2-30WT8 lamps; Cat No 742, 2-8 W/T5 lamps; Cat No 746, 2-15 W/T8 lamps.
Notes:
1. *For wall mount only. Note: The above equipment is Certified for use in Recreational Vehicles where the
acceptability of the combination is to be determined by the Canadian Standards Association.
2. Prefix, suffix with Cat No may be provided for product category and customer code.
sr
http://directories.csa-international.org/xml_transform.asp?xml=certxml\038177_0_000-3429-01.xml&xsl... 12/20/2007
Page 1 of 3
Certification Record
ACCESSORIES FOR USE ON SUBMITTOR'S SKID PACKAGES Class I, Division 2, Group D; Class IZone 2 IIA
l Phone Jack; for use with Intrinsically Safe Voice Powered Pones
l Servo Actuator; P/N 190508Cx, (MOOG) when connected to a Certified 28 V 300 Ohm Safety Barrier per Drwg 190508
l Velocity Vibration Transducer; P/N 120649-x (CEC 4-131) when connected to CSA Certified safety barriers MTL761 or Stahl
8901 per Instruction Drawing No 613771
l COAX Y-Tap Connectors, Allen-Bradley, Model numbers, 1786-TPR Series A and B; 1786-TPS Series A and B; 1786-TPYR
Series A and B; 1786-TYPS Series A and B; 9904-TPR Series A and B; 9904-TPS Series A and B; 9904-TPYR Series A and B;
9904-TPYS Series A and B.
l Solar 1020458-3, 1020458-4 Isothermal thermocouple reference PCB, 32 Volts max
l Temperature Probe Assembly, Thermocouples, deemed suitable for installation in intrinsically safe or non-incendive systems as
simple devices:
P/N 1013027, type K P/N 1029426, type K P/N 186167-x, type K
http://directories.csa-international.org/xml_transform.asp?xml=certxml\035592_0_000-9098-01.xml&xsl=xsl/certrec.xsl 3/27/2006
Page 2 of 3
l Temperature Probe Assembly, platinum RTD, P/N 916144Cx, P/N 120702 Type K Thermocouple, RTD P/N 1069160.
Ex d IIB, T6
Class I, Groups C & D; Temperature Code T6; Enclosure Type 4X
l Solar Model 200133-xxxx Industrial Gas Turbine Ignition System rated 10-32 Vdc input (26 Vdc Nominal at 2.5 A); 18 KV,
0.40A output. . Ambient temperature range –20º C to +70ºC. Temperature Code T6.
Model Number Nomenclature 200133-xxxx
Where xxxx = 1000 Aluminum enclosure 1061367-100 with 919340-C2 ignition cable
1100 Aluminum enclosure 1061367-100 with 120710-1-ignition cable
1200 Aluminum enclosure 1061367-100 with 945106-C2-ignition cable
1300 Steel enclosure 1061374-100 with 919340-C2-ignition cable
1400 Steel enclosure 1061374-100 with 120710-1-ignition cable
1500 Steel enclosure 1061374-100 with 945106-C2-ignition cable
Note: This equipment is certified as a component for use in the submitters certified equipment.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\035592_0_000-9098-01.xml&xsl=xsl/certrec.xsl 3/27/2006
Page 3 of 3
http://directories.csa-international.org/xml_transform.asp?xml=certxml\035592_0_000-9098-01.xml&xsl=xsl/certrec.xsl 3/27/2006
Page 1 of 2
Certification Record
Class I, Div. 2; Groups A, B, C and D, Class II, Groups E, F and G; Class III:
Notes:
1. Switches have been tested for 100,000 operations, ac heavy pilot duty.
2. Unless the switches are provided with an acceptable grounding means, the switches are Certified as components
http://directories.csa-international.org/xml_transform.asp?xml=certxml\024226_0_000-3218-06.xml&xsl=... 12/6/2007
Page 2 of 2
only for use with other equipment, where the suitability of the combination shall be determined by CSA
International.
3. The switches are suitable for installation in (or through the wall of) a suitable enclosures with provision for
connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction.
/vem
http://directories.csa-international.org/xml_transform.asp?xml=certxml\024226_0_000-3218-06.xml&xsl=... 12/6/2007
Page 1 of 4
Certification Record
Class I, Div. 1, and/or Div 2, Groups C, D; Class II, Div. 1 and/or Div 2, Groups E, F, G:
l Alternating current motors, squirrel cage, 2300V max a.c., 250 Hz max, fixed frequency, 0 to 120Hz variable
frequency, single or polyphase, Class A, B, F or H insulation, continuous or intermittent duty as follows:
Notes:
1. The motor frame designation may have suffixes and prefixes added which identify mechanical construction
variations.
2. Also Class I, Group C and D and Class II, Groups E, F, G motors with CSA Certified or UL listed brakes. The
brakes in these explosion-proof and dust-ignition-proof assemblies are intended essentially for holding purposes
and may be used for stopping light inertia loads.
3. Motors are suitable for use with certified inverts; Type PWM, VSI, VVI or CSI.
4. Motors for use with inverter drives are suitable for continous duty only with Class B, F, or H insulation.
5. Alternate IEC Frame Designation to Nema Frame designation stated above are as follows:
http://directories.csa-international.org/xml_transform.asp?xml=certxml\019467_0_000-4228-01.xml&xsl... 11/19/2007
Page 2 of 4
215T 132S, 132M 210T
254T --- 250T
256T 160M, 160L 250T
284T --- 280T
286T 180M, 180L 280T
324T --- 320T
326T 200M, 200L 320T
364T --- 360T
365T 225S, 225M 360T
404T --- 400T
405T 250S, 250M 400T
444T --- 440T
445T 280S, 280M 440T
447T 280K 440T
449T 280H 440T
(+) - IEC frames are identical to the NEMA frames except for mounting dimensions and may be marked with a kilowatt
rating corresponding to the NEMA horsepower rating such that HP (0.746) = KW.
l Alternating current, squirrel cage Induction Motors, Type "XE", rated 2300V ac max; Horsepower as tabulated
below; 2 or 4 pole, 1.0 Service Factor, single or polyphase. Class B, F or H insulation for Frames 320 through
365T; Class H insulation for Frame 405T, for use with Pulse Width Modulated (PWM) variable frequency drives.
Notes:
l Alternating current motors submersible in water and sewage, squirrel cage, 600V ac, 120Hz max fixed frequency,
0 to 120Hz variable frequency, single or polyphase, Class A, B, F or H insulation continuous or intermittent duty
as follows:
http://directories.csa-international.org/xml_transform.asp?xml=certxml\019467_0_000-4228-01.xml&xsl... 11/19/2007
Page 3 of 4
320TY 75
360TY 135
440TY 460
Note: Motors are suitable for use with certified inverters, Types PWM, VSI, VVI or CSI, continous duty only with Class
B, for H insulation.
Class I, Div 1 and/or Div 2, Group D, Class II, Div 1 and/or Div 2, Groups E, F and G:
l Shaker duty motors, Frames 182T, 184T, 213T, 215T, 254T, 256T, 284T and 286T, 600V ac max, polyphase,
60Hz max fixed frequency, 0 to 120Hz variable frequency 15 hp max, 3600 rpm max Insulation Class B or F,
continuous or intermittent duty. Motor frame designation may have suffixes and prefixes added which identify
mechanical construction variations.
Class I, Div 2, Groups A, B, C, D; Class II, Div 2, Groups F and G; Class III, Div 2; Temperature Coded:
Alternate
Type Max Max Temp. Frame IEC***
Designation Hp * Volt Code** Frame Size Design. Encl. Type Frame
Notes:
1. ***IEC frames are identical to the NEMA frames except for mounting dimensions and may be marked with a
kilowatt rating corresponding to the NEMA horsepower rating.
2. # Temperature Code: T4, T3C, T3, T2.
3. *Motors may be marked in kW ratings instead o or in addition to horsepower.
4. ** T4 motors may alternatively be marked T3C - T2; T3C motors may alternatively be marked T3B - T2; T3
motors may alternatively be marked T2D - T2.
5. Enclosure Code:
A - DP Drip-proof
B - G Guarded
C- WP Weatherproof or Weather Protected
D - TEFC Totally-Enclosed Fan-Cooled
E - TFNV Totally-Enclosed Non-Ventilated
6. Enclosure Types: "Drip-proof" (DP), "Guarded" (G), and "Weatherproof" (WP) are suitable for Class I, Div 2,
http://directories.csa-international.org/xml_transform.asp?xml=certxml\019467_0_000-4228-01.xml&xsl... 11/19/2007
Page 4 of 4
Groups A, B, C, and D only.
7. Frame size designation may be followed with suffix letter(s), to denote minor mechanical variations.
Class I, Div 2, Groups A, B, C, D; Class II, Div 2, Groups F and G; Class III, Div 2; Temperature Coded:
l AC Induction Motors, Single or three phases, for use with PWM Inverter Duty as tabulated below:
Temperature Code***
CHP 60- VT CT CT*
90 0-60 30-60 0-60
HZ HZ HZ HZ
P, PM, PR 182-184T 180T 112M 1000 5 T4 T4 T4 T3C
P, PM, PR 213-215T 210T 132S, 132M 1000 10 T4 T4 T4 T3C
P, PM, PR 254-256T 250T 160M, 160L 1000 20 T3C T3C T3C T3A
P, PM, PR 284-286T 280T 180M, 180L 1000 30 T3C T3C T3C T3A
P, PM, PR 324-326T 320T 200M, 200L 1000 50 T3C T3C T3C T3A
P, PM, PR 364-365T 360T 225S, 225M 1000 75 T3A T3A T3A T3A
P, PM, PR 404-405T 400T 250S, 250M 1000 100 T3A T3A T3A T3A
P, PM, PR 444-445T 440T 280S, 280M 2300 150 T3A T3A T3A T3A
P, PM, PR 447-449T 440T 280K, 280E 2300 300 T3A T3A T3A T3A
P, PM, PR L449-4412T 440T 280H 2300 450 T3 T3A T2D T2D
**IEC frames are identical to the NEMA frames except for mounting dimensions and may be marked with a
kilowatt rating corresponding to the NEMA horsepower rating.
*** T4 motors may alternatively be marked T3C - T2; T3C motors may alternatively be marked T3B - T2;
T3 motors may alternatively be marked T2D - T2.
Notes:
1. Enclosure Type:
TEFC - Totally-Enclosed Fan-Cooled
2. Frame size designation may be followed with suffix letter(s), to denote minor mechanical variations.
3. PWM carrier frequency shall be 2 kHz or higher.
/ka
http://directories.csa-international.org/xml_transform.asp?xml=certxml\019467_0_000-4228-01.xml&xsl... 11/19/2007
Page 1 of 2
Certification Record
l Frames 48 and 56, 600V ac max, 25-120Hz, single or polyphase, 7200 rpm max; 3/4 hp max, 75C temperature
rise.
l Frames 48 and 56; 600V ac max, 6-120Hz single or polyphase, 7200 rpm max: 3/4 hp max, 75C temperature rise.
l Frames 56, 61, 143, 145, 180, 182 and 184, 600V ac max 6-120Hz, single or polyphase, 7200 rpm max: 5 hp max,
75C temperature rise.
l Frame 56, 250V dc max, 3500 rpm max 1-1/2 hp max, 95C temperature rise.
1. Notes: Class I, Groups D and Class II, Groups E, F and G motors with brakes, The Type M disc brakes in
explosion-proof assemblies are intended essentially for holding purposes and may be used for stopping light inertia
loads. The Type D brakes which are induction type in the explosion-proof and dust-tight motor assemblies are
intended esentially for stopping light inertia loads.
2. Motors may be used with Variable Voltage Inverters (VVI), Current Source Inverters (CSI), and Pulse Width
Modulated Inverters (PWM) 3 hp max.
Class I, Group D:
l Frame 56 motors rated 115/230V ac, 1 ph, Class B insulation; Models E78V8415N (3/4 hp, 60Hz), E78V8416N
(1/2 hp, 60Hz) and E78V9473N (1/2 hp, 50Hz); for use with Timer Controller P.N. 79334-29-A. Timer is
intrinsically safe when connected to motor per Drawing D-14789. Temperature Code T3C.
Note: Timer is Certified as a component for installation in a suitable enclosure as acceptable to the Local Inspection
Authority having jurisdiction.
l Frame 56, 61, 143 or 145 motors, single phase, rated 115/230V ac, 60Hz, 80C temperature rise, horsepower rating
not to exceed 1 hp for 115V ac motors or 2 hp for 230V ac motors; for use with timer controller P/N 79334-29-B.
Timer is intrinsically safe when connected to motor per Drawing D-14789, Temp Code T3C. Note: Timer is
Certified, as a component, for installation in a suitable enclosure as acceptable to the local inspection authority
having jurisdiction.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\006771_0_000-4228-01.xml&xsl=... 1/15/2008
Page 2 of 2
Class I, Group D; Class II, Groups F and G:
l Frame 56, 61, 143 or 145 motors, single phase; rated 115/230V ac, 60Hz, 80C temperature rise, horsepower rating
not to exceed 1hp for 115V ac motors or 2 hp for 230V ac motors; for use with timer controller P/N 79334-32-A or
P/N 79334-32-D. Timer is intrinsically safe when connected to motor per Dwg D-14832. Temperature Code T3C.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\006771_0_000-4228-01.xml&xsl=... 1/15/2008
Page 1 of 2
Certification Record
l Frames 48 and 56, 600V ac max, 25-120Hz, single or polyphase, 7200 rpm max; 3/4 hp max, 75C temperature
rise.
l Frames 48 and 56; 600V ac max, 6-120Hz single or polyphase, 7200 rpm max: 3/4 hp max, 75C temperature rise.
l Frames 56, 61, 143, 145, 180, 182 and 184, 600V ac max 6-120Hz, single or polyphase, 7200 rpm max: 5 hp max,
75C temperature rise.
l Frame 56, 250V dc max, 3500 rpm max 1-1/2 hp max, 95C temperature rise.
Notes:
1. Class I, Groups D and Class II, Groups E, F and G motors with brakes, The Type M disc brakes in explosion-proof
assemblies are intended essentially for holding purposes and may be used for stopping light inertia loads. The
Type D brakes which are induction type in the explosion-proof and dust-tight motor assemblies are intended
esentially for stopping light inertia loads.
2. Motors may be used with Variable Voltage Inverters (VVI), Current Source Inverters (CSI), and Pulse Width
Modulated Inverters (PWM) 3 hp max.
Class I, Group D:
l Frame 56 motors rated 115/230V ac, 1 ph, Class B insulation; Models E78V8415N (3/4 hp, 60Hz), E78V8416N
(1/2 hp, 60Hz) and E78V9473N (1/2 hp, 50Hz); for use with Timer Controller P.N. 79334-29-A. Timer is
intrinsically safe when connected to motor per Drawing D-14789. Temperature Code T3C. Note: Timer is
Certified as a component for installation in a suitable enclosure as acceptable to the Local Inspection Authority
having jurisdiction.
l Frame 56, 61, 143 or 145 motors, single phase, rated 115/230V ac, 60Hz, 80C temperature rise, horsepower rating
not to exceed 1 hp for 115V ac motors or 2 hp for 230V ac motors; for use with timer controller P/N 79334-29-B.
Timer is intrinsically safe when connected to motor per Drawing D-14789, Temp Code T3C.
Note: Timer is Certified, as a component, for installation in a suitable enclosure as acceptable to the local inspection
http://directories.csa-international.org/xml_transform.asp?xml=certxml\006771_0_000-4228-81.xml&xsl=... 1/15/2008
Page 2 of 2
authority having jurisdiction.
l Frame 56, 61, 143 or 145 motors, single phase; rated 115/230V ac, 60Hz, 80C temperature rise, horsepower rating
not to exceed 1hp for 115V ac motors or 2hp for 230V ac motors; for use with timer controller P/N 79334-32-A or
P/N 79334-32-D. Timer is intrinsically safe when connected to motor per Dwg D-14832. Temperature Code T3C.
http://directories.csa-international.org/xml_transform.asp?xml=certxml\006771_0_000-4228-81.xml&xsl=... 1/15/2008
NOIV.E189693 - Auxiliary Devices for Use in Hazardous Locations Page 1 of 1
NOIV.E189693
Auxiliary Devices for Use in Hazardous Locations
Page Bottom Print-friendly version Questions? Previous Page
Guide Information
Timer modules.
Models KOP118J7, -128J7, -141J7 , -160J7 followed by additional letters and/or number.
This page and all contents are Copyright © 2004 by Underwriters Laboratories Inc.®
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed
and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following
conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material.
In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2004 Underwriters
Laboratories Inc.®"
file://S:\ccerts\UL\CRT-E189693-EN.htm 12/16/2004
NOIV7.E189693 - Auxiliary Devices for Use in Hazardous Locations Certified for Canada Page 1 of 1
NOIV7.E189693
Auxiliary Devices for Use in Hazardous Locations Certified for
Canada
Page Bottom Print-friendly version Questions? Previous Page
Guide Information
Timer modulesModels KOP118J7, -128J7, -141J7 , -160J7 followed by additional letters and/or
number.
This page and all contents are Copyright © 2004 by Underwriters Laboratories Inc.®
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed
and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following
conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material.
In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2004 Underwriters
Laboratories Inc.®"
file://S:\ccerts\UL\showpage.htm 12/16/2004
VAPT.E37068 - Solenoids, For Use in Hazardous Locations Page 1 of 1
VAPT.E37068
Solenoids, For Use in Hazardous Locations
Page Bottom Questions? Previous Page
Guide Information
Class I, Groups C and D; Class I, Div 2, Groups A, B, C and D ; Class II, Groups E, F and G.
This page and all contents are Copyright © 2003 by Underwriters Laboratories Inc.®
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed
and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any
manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission
from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must
include a copyright notice in the following format: "Copyright © 2003 Underwriters Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=VAPT.E37068&ccnshorttit
8/7/2003
Page 1 of 2
Certification Record
l Synchronous generators, Type Coded xPy-z, Rated, 13800V max, 3 phases, 50 and/or 60 Hz , 6000
kVA max (TEAAC machines); 11250 kVA max (ODP machines); 8125 kVA max (WPII machines);
temperature rise B and/or F, class F insulated, maximum output per frame as given below versus
generator enclosure type:
4P7 -- -- -- 1750
4P8.1/6.6 -- -- -- --
4P9.1/9.6 -- -- -- --
4P10.7 7875 -- -- --
4P63.5 -- -- -- --
Note 1: The maximum outputs are giving for 60Hz application - Multiply by 0.875 for 50Hz maximum output at 40°C
ambient air
Note 2: For a cooling air above 40°C, de-rate (Multiply) the output by 0.94 for a cooling air less or equal to 45°C, and
de-rate by 0.89 for a cooling air between 45°C and 50°C.
Ex nA II A & II B + H2, T3 :
l Synchronous generators, Type Code xPy-z; Rated, 13800V max, 3 phases, 50 and/or 60 Hz , 8125
kVA max (ODP & WPII machines); temperature rise B and/or F, class F insulated, maximum output
per frame as given below versus generator enclosure type:
http://directories.csa-international.org/xml_transform.asp?xml=certxml\009868_S_000-4228-01.xml&xsl=... 2/19/2008
Page 2 of 2
Maximum Output (kVA) at 60Hz (See Note 1)
4P7 -- -- -- --
4P8.1/6.6 -- -- -- --
4P9.1/9.6 -- -- -- --
4P10.7 -- -- -- --
4P11/12 -- -- -- --
4P63.5 -- -- -- --
Note 1: The maximum outputs are giving for 60Hz application - Multiply by 0.875 for 50Hz maximum output at 40°C
ambient air
Note 2: For a cooling air above 40°C, de-rate (Multiply) the output by 0.94 for a cooling air less or equal to 45°C, and
de-rate by 0.89 for a cooling air between 45°C and 50°C.
/mer
http://directories.csa-international.org/xml_transform.asp?xml=certxml\009868_S_000-4228-01.xml&xsl=... 2/19/2008
Page 1 of 2
Certification Record
l Synchronous generators, Type Coded xPy-z, Rated, 13800V max, 3 phases, 50 and/or 60 Hz , 6000
kVA max (TEAAC machines); 11250 kVA max (ODP machines); 8125 kVA max (WPII machines);
temperature rise B and/or F, class F insulated, maximum output per frame as given below versus
generator enclosure type:
4P7 -- -- -- 1750
4P8.1/6.6 -- -- -- --
4P9.1/9.6 -- -- -- --
4P10.7 7875 -- -- --
4P63.5 -- -- -- --
Note 1: The maximum outputs are giving for 60Hz application - Multiply by 0.875 for 50Hz maximum output at 40°C
ambient air
Note 2: For a cooling air above 40°C, de-rate (Multiply) the output by 0.94 for a cooling air less or equal to 45°C, and
de-rate by 0.89 for a cooling air between 45°C and 50°C.
l Synchronous generators, Type Code xPy-z; Rated, 13800V max, 3 phases, 50 and/or 60 Hz , 8125
kVA max (ODP & WPII machines); temperature rise B and/or F, class F insulated, maximum output
per frame as given below versus generator enclosure type:
http://directories.csa-international.org/xml_transform.asp?xml=certxml\009868_S_000-4228-81.xml&xsl=... 2/19/2008
Page 2 of 2
Maximum Output (kVA) at 60Hz (See Note 1)
4P7 -- -- -- --
4P8.1/6.6 -- -- -- --
4P9.1/9.6 -- -- -- --
4P10.7 -- -- -- --
4P11/12 -- -- -- --
4P63.5 -- -- -- --
Note 1: The maximum outputs are giving for 60Hz application - Multiply by 0.875 for 50Hz maximum output at 40°C
ambient air
Note 2: For a cooling air above 40°C, de-rate (Multiply) the output by 0.94 for a cooling air less or equal to 45°C, and
de-rate by 0.89 for a cooling air between 45°C and 50°C.
/mer
http://directories.csa-international.org/xml_transform.asp?xml=certxml\009868_S_000-4228-81.xml&xsl=... 2/19/2008
Page 1 of 2
Certification Record
l Snap switch, Cat No 057-0030, 057-0690 and 057-0696, spdt; and 057-0057, 057-0691 and 057-0697, dpdt; all
rated 11A, 1/4 hp, 125 or 250V ac; 3A inductive or 5A resistive, 28V dc max, 0.5A, 125V dc, leads factory sealed.
l Snap switch, Cat Nos. 057-0130, 057-0692 and 057-0698, spdt; and 057-0157, 057-0693 and 057-0699, dpdt; all
rated 1A, 125 or 250V ac; 0.5A inductive or 1.0A resistive, leads factory sealed.
l Snap Switches,
Cat. No. 057-0760, spdt, 11 A, 0.25hp, 125/250 V, 60Hz; 5 A resistive at 30 Vdc; 0.5 A resistive at 125 Vdc
Cat. No. 057-0761, dpdt, 11 A, 0.25hp, 125/250 V, 60Hz; 5 A resistive at 30 Vdc; 0.5 A resistive at 125 Vdc
Cat. No. 057-0762, spst, 1 A, 125 V, 60Hz.; 1 A resistive, 0.5 A inductive, 30 Vdc
Cat. No. 057-0763, dpdt, 1 A, 125 V, 60Hz.; 1 A resistive, 0.5 A inductive, 30 Vdc
Cat. No. 057-0770, spdt, 11 A, 0.25hp, 125/250 V, 60Hz; 5 A resistive at 30 Vdc; 0.5 A resistive at 125 Vdc
Cat. No. 057-0771, dpdt, 11 A, 0.25hp, 125/250 V, 60Hz; 5 A resistive at 30 Vdc; 0.5 A resistive at 125 Vdc
Cat. No. 057-0772, spdt, 1 A, 125 V, 60Hz.; 1 A resistive, 0.5 A inductive, 30 Vdc
Cat. No. 057-0773, dpdt, 1 A, 125 V, 60Hz.; 1 A resistive, 0.5 A inductive, 30 Vdc.
Class I, Division 2, Groups A, B, C, and D, Class II, Groups E, F, and G, Class III
l Snap Switch
Cat. No. 057-0826, dpdt, 1 A, 125V, 60Hz.; 1 A resistive, 0.5 A inductive, 30 Vdc.
Note: The grounding of the metal body of Cat. No. 057-0826 is to be evaluated in the final installation by the inspection
authority having jurisdiction.
Class I, Groups B, C, D; Class II, Groups E, F, G; Class III; Encl. Type 4X and 13:
http://directories.csa-international.org/xml_transform.asp?xml=certxml\034146_0_000-6248-01.xml&xsl=xs... 2/1/2008
Page 2 of 2
l Series 100P Explosion proof Pressure Switches, adjustable, 100P-xxxxxxx; Enclosure Type: 4X, 13; Relay
contacts rated: (i) 15A, 125/250/480Vac; 0.5A, 125 Vdc (ii) 11A, 125/250Vac; 0.5A, 125V dc (iii) 15A,
125/250/480Vac; 1A, 125 Vdc (iv) 1A, 125Vac. Maximum operating ambient: 75C. Max operating pressure:
3000 psi for all ranges except range one which is 600 psi.
l 100P, 110P and 160P Series pressure switches, rated 11A, 1/4 hp, 125/250Vac; 5A, 125/250 Vac, 5A resistive, 3A
inductive, 28Vdc; 0.5A resistive, 125V dc; "M" option: 1A resistive, 0.5A inductive, 125Vac. Temperature Code:
T4, max ambient temp: 74°C.
l 200P Series Pressure Switches, rated 11A, 1/4 hp, 125/ 250Vac; 5A, 125/250 Vac, 5A resistive, 3A inductive,
28Vdc; 5A resistive, 125Vdc; "M" option: 1A resistive, 0.5A inductive, 125Vac. Temperature Code: T4, max
ambient: 74C°; Encl. Type: 4X, 13.
/ka
http://directories.csa-international.org/xml_transform.asp?xml=certxml\034146_0_000-6248-01.xml&xsl=xs... 2/1/2008
Page 1 of 1
Certification Record
Class I, Groups B, C, D; Class II, Groups E, F, G; Class III; Enclosure Type 4X and 13.
/mg
http://directories.csa-international.org/xml_transform.asp?xml=certxml\034146_0_000-4658-01.xml&xsl=xs... 2/1/2008
WOYR2.E78925 - Switches, Special Use - Component Page 1 of 2
% &'( ) * + , -./
0 1
# 2 # # & !
! " %34567
865 % " 9' 9:%
%; 0 <: +% % =>353? 	
3- - A
- 6 3- - 5
- > 8- - 5
6 66 88 85 2 +
- 8- - 5
633C'C
3 - A
- 6 3 - 5
9@3 - A 77 -
6 B 8D B
- > 8 - 5
6 66 88 85 - >8/
- 8 - 5
; 76? !73 77 - B 8D 6
!" #
! $!
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=... 11/11/2008
WOYR2.E78925 - Switches, Special Use - Component Page 2 of 2
) I + 0 "
E 6>>4& ' F
" (
&'( * !& # < &' '
&'( * !& # 9
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=... 11/11/2008
SECTION: 10.03