Technical CRGO
Technical CRGO
Technical CRGO
Grain oriented Electrical Steel CRGO is undoubtedly the most important soft magnetic
material in use today. Wheather in small transformer, distribution transformer or in large
transformer & generator, grain oriented electrical steel CRGO is a must for the production
of energy saving electrical machines.
Grain oriented Electrical Steels are iron-silicon alloys that provide low core loss and high
permeability needed for more efficient and economical electrical transformers. CRGO
Grain oriented grades of electrical steel are typically used for transformer cores and large
generators.
Non-oriented Electrical steel CRNGO fully processed steels are iron-silicon alloys with
varying silicon contents and have similar magnetic properties in all directions in plan of
the sheet. Non-oriented Electrical steel are principally used for motors, generators,
alternators, ballasts, small Transformers and a variety of other electromagnetic
applications.
The earliest soft magnetic material was iron, which contained many impurities.
Researchers found that the addition of silicon increased resistivity, decreased hysteresis
loss, increased permeability, and virtually eliminated aging.
Substantial quantities of Grain oriented Electrical steel CRGO are used, mainly in power
and distribution transformers. However, it has not supplanted non-oriented Electrical
steel, which is used extensively where a low-cost, low-loss material is needed,
particularly in rotating equipment. Mention should also be made of the relay steels, used
widely in relays, armatures, and solenoids. Relay steels contain 1.25 to 2.5% Si, and are
used in direct current applications because of better permeability, lower coercive force,
and freedom from aging.
M-0H 1 1.88
27ZH100 1 1.8
Thickness (mm)
3 Up to 0.23 15
0.27 to 0.30 15
0.35 20
7 Angle ± 5 Minutesw
Building factor
After several years of experience and determination for providing high quality products to our valued customers, we have been able to bring down the building factor in our production process.
Building factor (BF) is a very important factor used in determining the No Load Losses of a transformer. It is an empirically derived value based on previous experiences. It ranges from 1.08 to
1.35 for three phases, three limb cores. Generally, BF is dependent on various important factors like core geometry, quality of workmanship of core and grade of material being used.
Reducing the BF is a measure that we have incorporated over time by taking precautionary step like proper handling, maintaining appropriate parameters within the processes and controlling
burr and edge camber levels.
Dimension:
All Size Area In: MM
SR. SIZE A B C D E F G H I
9 33 NO 94 56 14 14 28 14 14 84 6.75
17 9 NO (9 X 12) 228.6 152.4 38.1 38.1 76.2 38.1 38.1 228.6 12.5
18 10 (101/2 X 14) 266.7 177.8 44.45 44.45 88.9 44.45 44.45 266.7 12.5
19 100 NO(12 X 16) 304.8 203.2 50.8 50.8 101.6 50.8 50.8 304.8 12.5
20 200 NO (15 X20) 381 254 63.5 63.5 127 63.5 63.5 381 12.5
40 mm 100 -0.0/+1 mm
Grade
M3 0.27 AT/CM at 1.5T/50Hz
MAGNETIC CHARACTERISTICS M4 0.29 AT/CM at 1.5T/50Hz
M5 0.34 AT/CM at 1.5T/50Hz
M6 0.40 AT/CM at 1.5T/50Hz
Comparative Chart
Toroidal core & C.T manufacturers need to know the B-H values of CRGO Materials after annealing over a wide range of Flux densities ranging from 100 Gauss to 19000 Gauss. We give below
the actual values obtained on a core of size 150 mm OD x 100 mm ID x 25 mm HT with a stacking factor of 95% and a frequency of 50Hz.
Comparative 8-h Curves Tabulated Values For Different Grades Of CRGO Toroidal Core of Size 150mm Od X 100 mm Id X 25 mm Ht
1.95 -- -- -- 1.35
TOLERANCE
0.18 +0.02
0.20 +0.02
150 0.23 +0.02
0.02 or under +0.20
or under 0.27 +0.03
0.30 +0.03
0.35 +0.03
0.18
+0.02 +0.02
0.20
+0.02
over 150 0.23 0.02
+0.03 +0.30
to 400 0.27 or under
+0.03
0.30
+0.03
0.35
0.04
1.0 or under
or under
0.18 +0.02
0.20 +0.02
over 400 0.23 +0.02 0.03
+0.50
to 750 0.27 +0.03 or under
0.30 +0.03
0.35 +0.03
0.18 +0.02
0.20 +0.02
0.23 +0.02 0.03 +0.6
over 750
0.27 +0.03 or under 0
0.30 +0.03
0.35 +0.03
Note : Stipulation of camber shall be applied only for the steel strips (width 75mm over).
Besides the Watt Losses at specific flux densities of 1.5 T and 1.7 T CRGO
manufacturers also give curves of indicating Watt Losses ad A.C. Magnetization at
various flux densities. These curves are of immense help to Transformer designers, and
available on request.
Conventional CRGO materials (M4, M5, M6) are used regularly for cores in Transformers.
However recently due to environmental protection, energy savings are becoming a very
important factor and minimizing care loss in Transformers is becoming a must. Nippon
Steel Corporation has come out with low loss Hi-B materials, which guarantee low Watt
Losses at 1.5 Tesla flux density. Such materials are called Hi-B materials. Table 3 gives
magnetic properties of Hi-B material. Popular Hi-B grades used in India are 23 MOH & 27
MOH Watt.
Hi - B CRGO MATERIALS :
Core Loss Lamination Factor
Thickness
Max. Typical Typical Typical
Grade
W W W W
mm mil W (W/Kg) B (T) %
(W/Kg) (W/Kg) (W/Kg) (W/Kg)
Applications
Non oriented fully processed steels are iron-silicon alloys with varying silicon contents and have similar magnetic properties in all directions in the plan of the sheet. They are principally used for
motors, generators, alternators, ballasts, small transformers and a variety of other electromagnetic applications.
Flux Density v/s Losses : Digital Iron Loss Tester VDW 2065
These values are for reference only. All values are in Watt/kg @ 50 Hz. After manufacturing the watts
losses of finished product increases by 10% to 20% Approx Introduction
We at Sun Power Enterprise, use Veer manufactured Digital Iron Loss Tester VDW-2065
is portable & easy to use instrument which is very useful to find Watt loss of electrical
steel immediately. Internationally accepted standard method of testing is Epstein Frame
method but that method needs 30mm x 305 mm size & min. 250g weight of material.
Stamping, Laminations can not be tested on Epstein frame because of size.So, we have
designed a direct reading type Single Sheet Tester called Digital Iron Loss Tester VDW-
2065 which providers very fast testing of final products like Stamping, EI & Other
Laminations etc.
Theory of operation
The Probe is provided with two coils. One coil is for for excitation & second one is for
detection of magnetic flux. When you put Probe on test specimen, it completes magnetic
path. Watt meter measures iron loss if specimen & you can see iron Loss (Watt/Kg or
Watt/lb) immediately on Seven Segment Red digital on front panel. You can set
Thickness up to 0.65mm & Induction up 1.8 Tesla (18000 Gauss) using respective setting
knob.
Application
Transformer Lamination & Motor Stamping Manufacturer, Traders, suppliers, users etc.
Educational Institutes for Electrical/Metallurgy Department, Electrical Laboratories etc.
Transformer, Motor, Pump, Ups, Inverter, Battery Charger, Choke manufactures.
Specifications
Parameters VDW-2055 VDW-
(Standard) 2065E(Economy)
Flux Density M3 M4 M5 M6
23PHD85 27ZDKH90 27ZDKH95 23 MOH 27 MOH 30 MOH
(Tesla) 0.23 0.27 0.30 0.35
1.30 0.46 0.51 0.48 0.53 0.57 0.57 0.49 0.64 0.68 0.73
1.35 0.49 0.55 0.51 0.57 0.60 0.62 0.53 0.68 0.74 0.79
1.40 0.53 0.59 0.57 0.61 0.66 0.65 0.58 0.74 0.80 0.86
1.45 0.57 0.63 0.61 0.66 0.70 0.70 0.64 0.78 0.87 0.94
1.46 0.58 0.64 0.62 0.67 0.71 0.71 0.65 0.80 0.88 0.97
1.48 0.60 0.66 0.64 0.66 0.73 0.74 0.67 0.82 0.91 1.03
1.50 0.61 0.67 0.66 0.70 0.74 0.76 0.70 0.84 0.94 1.11
1.52 0.63 0.69 0.68 0.72 0.76 0.78 0.72 0.88 0.97 1.14
1.54 0.65 0.71 0.70 0.74 0.79 0.80 0.75 0.90 1.01 1.18
1.56 0.67 0.73 0.72 0.76 0.81 0.83 0.78 0.93 1.04 1.22
1.58 0.69 0.75 0.74 0.78 0.83 0.85 0.81 0.96 1.08 1.26
1.60 0.71 0.77 0.76 0.80 0.85 0.87 0.85 1.00 1.12 1.30
1.62 0.73 0.79 0.79 0.83 0.89 0.90 0.89 1.03 1.16 1.35
1.64 0.75 0.81 0.83 0.85 0.91 0.93 0.93 1.07 1.20 1.40
1.66 0.78 0.84 0.87 0.88 0.94 0.96 0.98 1.10 1.25 1.45
1.68 0.81 0.87 0.91 0.93 0.96 1.00 1.03 1.15 1.30 1.51
1.70 0.84 0.90 0.95 0.95 1.00 1.05 1.09 1.20 1.36 1.57
1.72 0.86 0.93 1.01 0.98 1.02 1.07 1.15 1.24 1.42 1.64