R4R 3 EN2700 B Pilot Valve Cartridge
R4R 3 EN2700 B Pilot Valve Cartridge
R4R 3 EN2700 B Pilot Valve Cartridge
DENISON HYDRAULICS
Pressure Reducer Valve R4R
Proportional Pressure Reducer Valve R4R . . . P2
FEATURES x High Performance: R4 valves are designed for a maximum pressure of 350 bar
and a flow capacity ranging from 90 l/min (3/8HH) to 600 l/min (11/4HH).
x Sensitive Control: The DENISON poppet design delivers the minimum possible
friction, superior hysteresis and optimum response to changes in operating con-
ditions.
x Wide Selection: In addition to the various mounting options for the main valve
body, or as cartridge for manifold applications, the ordering code offers a range
of control options for valves and accessories. A solenoid vent valve is available
(VV01).
X1 Y1 (ext. alternative)
Z
X
SYMBOL R4R
Y external
A B
R4R06
X1 Y1 (ext. alternative)
X Y
SYMBOL R4R . . . P2 Proportional
pilot valve P2
Y external
A B
R4R06 . . . P2
GENERAL DENISON Pressure Valves are pilot operated controls consisting of two or three
sections; either a high flow, poppet type seat valve section controlled by the low
flow, adjustable pilot mounted on top or in the case of the Proportional Pressure
Reducer Valve, the proportional section P2 sandwiched between the pilot stage
and the main body.
R4R Reducer Valves are used to control the pressure in the secondary part of a
hydraulic circuit, and to maintain this pressure as set by the control knob on the
pilot, or according to the current input on the R4R . . . P2.
The R4R can be vented electrically by means of an optional vent valve, VV01. This
valve is mounted between the pilot valve and the main body.
With the DENISON combined Seat Valve and Pilot design, and the range of springs
available, it is possible to achieve extremely precise pressure setting.
All valve components are subject to rigorous quality control, based on inter-
national standards, thus permitting worldwide operation and interchangeable
spare parts.
OPERATION With the secondary Port A unpressurized, the system pressure in Port B is applied
to the mini flow control valve of the pilot valve, to the pilot cone and seat (where
present also to the cone of the proportional pilot valve), and to the top surface Z
of the main poppet, which is held against the seat from the bottom side by the
comparatively weak spring force.
Below the setting pressure the pressure on Z lifts the main poppet downwards off
its seat and allows flow from Port B to Port A.
If the pressure in A exceeds the set point, the pressure in Z increases also to the
setting pressure and the pilot cone is lifted from its seat, releasing a small pilot flow
to tank 1).
This allows the pressure at the top of the main poppet to remain at the set point.
In the resulting float position only enough flow is passed from B to A to maintain the
outlet pressure in A, as determined by the pilot head setting.
If and when the pressure in the secondary Port A equals the pilot stage setting, the
main poppet closes. The small check valve in the main poppet prevents the
secondary system from exceeding the pilot setting by allowing excess pressure to
drain. This relief function has a very limited flow capacity up to 5 l/min.
1) The proportional valve P2 varies the pressure applied to the top of the main poppet,
in proportion to the current input to the solenoid.
The manual setting of the pilot stage determines the maximum pressure and
should be approximately 10 % higher than the max. adjustable pressure of the
proportional section (see also page 12).
omit
for version
without VV01
& without P2
1 2 3 4 5 6 7 8 0 1 2 3
1 Series 9
R4R = Pressure Reducer Valve
2 Size
03 = 3/8HH
06 = 3/4HH
10 = 11/4HH
3 Max. Pressure
0 = for cartridges only
5 = for body valves only k 350 bar
4 Body Mounting
Cartridge with pilot valve:
G = X1 + Y1 ports = G 1/4HH
E = X1 + Y1 ports = SAE-4 (7/16HH–20 UNF)
Subplate mounting:
9 = X1 + Y1 ports = G 1/4HH
7 = X1 + Y1 ports = SAE-4 (7/16HH–20 UNF)
Threaded body:
D = R4R06 = G 3/4HH; L-body; X1 + Y1 ports = G 1/4HH
B = R4R06 = SAE-12; L-body; X1 + Y1 ports = SAE-4 (7/16HH–20 UNF)
6 Type of Control
1 = Hand knob 32 mm dia.
2 = Hand knob 50 mm dia. (not for version with vent valve VV01 or P2)
3 = Acorn nut with lead seal
4 = Adjusting device with key lock, key order no. 700-70619-8
7 Drain Line
1 = external from the subplate or manifold (Y).
2 = external from the pilot head (Y1)
k k
W01 = 115 V / 60 Hz 1) G0R = 12 V
W02 = 230 V / 60 Hz G0Q = 24 V DC
AC
W06 = 115 V / 50 Hz G0H = 48 V
W07 = 230 V / 50 Hz 1 ) R4R with P2 = P2-G0R only
1 Design Letter
2 Seal Class
1 = NBR (Buna N) Standard
4 = EPDM
5 = FPM (Viton `)
3 Modifications
Minimum differential pressure between inlet & outlet pressure at various flow rates
R4R03 R4R06/10
R4R03 R4R06/10
0.6 kg 1.2 kg
X1 Y1 X1 Y1
1.8 dp.
Y X Y
X
B
B
A
3 / 8 HH-24
UNF or
M10; 20 lg.
Ports Function
B Pressure (inlet)
A Pressure (outlet)
X Internal pilot pressure
X1 Remote control or vent connection
Y, Y1 External drain
4 Mounting screws
Dimension Order-No.
3 /8 HH–24 UNF x 13 /4 HH lg. 359-15220-0
or
M10 x 45, DIN 912-12.9 700-71602-8
Weight: 2.7 kg
Panel opening
Ports Function
B Pressure (inlet)
A Pressure (outlet)
X1 Remote control or
vent connection
Y, Y1 external drain
M 0 or
3 / 8 HH-6 UNC
Block mounting face 6 lg.
Flatness 0.01 mm / 100 mm length
Surface finish CLA 1.27 ∑m
SUBPLATE Weight: 2 kg
7. (8 dp.)
Ports Function
B Pressure (inlet)
A Pressure (outlet)
X1 Remote control or
vent connection
Y, Y1 external drain
M 0 or
3 / 8 HH-6 UNC
18 lg.
Block mounting face
Flatness 0.01 mm / 100 mm length
Surface finish CLA 1.27 ∑m
7. (8 dp.)
Location hole
7.1 (8 dp.)
Location hole
Ports Function
B Pressure (inlet)
A Pressure (outlet)
X1 Remote control or
vent connection
Y, Y1 external drain
7. (8 dp.)
M 0 or
3 / 8 HH -6 UNC
18 lg.
Location hole
M 0
18 lg.
7. (8 dp.)
Weight: 3.3 kg
X1
Y1
Symbol
Note:
For full details of the proportional section refer to bulletin 3-EN 2200.
For additional installation with pilot operated control valves please consult DENISON.
X1 Y1
Symbols:
Pilot R4R Reducer Valve with Vent Valve VV01
valve
Main valve
11 B
or
12
Plug-in connector DIN 43650
X Y
A
09 B
Solenoid coil can be positioned:
– at 90 h intervals (AC) or
– in any position (DC) 10
AC Ù 149 X Y
DC = 160 A
Note:
For full details of the vent valve VV01
refer to bulletin 3-EN 215.
The product described is subject to continual development and the manufacturer reserves the right to change the specifications without notice.