Design Sup Fly 216+700 - 03.11.2015 PDF
Design Sup Fly 216+700 - 03.11.2015 PDF
Design Sup Fly 216+700 - 03.11.2015 PDF
AUTHORITY ENGINEER:
In
Joint Venture
with
CONTRACTOR:AFCONS INFRASTRUCTURELIMITED
PROJECT TITLE:
APPROVED
FOR APPROVAL OF Client Client
BY
LDS LDS
S.SUCHISMITA
MOHAPATRA
DESIGNER
JACOBS-CES
1. Design Data
4. Cable Profile
5. Stress Check
8 Transverse Analysis
BASIC DESIGN
DATA
Design of PSC Girder 34.35m span For FLYOVER AT CH.216+700
1. INNER GIRDER
a. MID SECTION
1450 1450
Individual section
950
Area
961962.5 mm2 240
0.962 m2 150
C.G. of section from bottom 75
1236.665 mm
353 353
Individual section
0
Area
678000 mm2 240
0.678 m2 0
C.G. of section from bottom 0
1130 mm
STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 07-Jul-15
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER MTON
JOINT COORDINATES
1008 0.0125 0 0; 2008 33.9275 0 0; 2009 16.97 0 0; 2010 1.795 0 0;
2011 3.795 0 0; 2012 32.145 0 0; 2013 30.145 0 0; 2123 7.9969 0 0;
2220 12.7691 0 0; 2221 21.1709 0 0; 2222 25.9431 0 0;
MEMBER INCIDENCES
1 1008 2010; 507 2009 2221; 508 2010 2011; 509 2011 2123; 510 2012 2008;
511 2013 2012; 638 2123 2220; 666 2013 2222; 668 2222 2221; 790 2009 2220;
DEFINE MATERIAL START
ISOTROPIC CONCRETE
E 2.21467e+006
POISSON 0.17
DENSITY 2.5
ALPHA 1e-005
DAMP 0.05
**********
END DEFINE MATERIAL
CONSTANTS
MATERIAL CONCRETE ALL
MEMBER PROPERTY AMERICAN
507 509 638 666 668 790 PRIS AX 0.962 IX 0.001 IY 0.001 IZ 0.7
1 510 PRIS AX 1.814 IX 0.001 IY 0.001 IZ 0.977
508 511 PRIS AX 1.388 IX 0.001 IY 0.001 IZ 0.838
SUPPORTS
1008 2008 PINNED
LOAD 1 LOADTYPE None TITLE DL
SELFWEIGHT Y -1 LIST ALL
PERFORM ANALYSIS
FINISH
Calculation of Dead Load during 2nd Stage & Shuttering Load
1.74t/m
34.35 m
A B
nd
(2 Stage Loading)
2.40t/m
34.35 m
A B
0.70t/m
34.35 m
A B
Calculation of bending moment and shear force (Shuttering Load) (Outer girder)
Shuttering Load
0.83t/m
34.35 m
A B
1 LANE 70R WHEEL MOST ECCENTRIC 802.00 1475.00 2395.00 2855.00 2891.00
1 LANE OF 70R TRACK MOST ECCENTRIC 658.00 1211.00 1971.00 2341.00 2358.00
1 LANE 70R WHEEL PLACED CENTRALLY ON IG 992.00 1695.00 2440.00 2594.00 1814.00
1 LANE 70R WHEEL PLACED(ONE WHEEL) ON IG 865.00 1518.00 2325.00 2522.00 2075.00
1 LANE 70R WHEEL MOST ECCENTRIC 408.00 354.00 276.00 200.00 241.00
1 LANE OF 70R TRACK MOST ECCENTRIC 333.00 290.00 232.00 170.00 207.00
INNER GIRDER{IG}
TYPE OF LOADING Deff (2m) L/8 (4.0m) L/4 (8.973m) 3L/7 (12.974m) L/2 (17.17m)
KNm KNm KNm KNm KNm
1 LANE 70R WHEEL PLACED CENTRALLY ON IG 470.00 365.00 242.00 256.00 373.00
1 LANE 70R WHEEL PLACED(ONE WHEEL) ON IG 425.00 348.00 245.00 216.00 305.00
1 LANE 70R WHEEL +70R PLACED AT 1.2m 70R 415.00 300.00 190.00 179.00 263.00
DISTANCE
70R 123.00 91.00 66.50 66.00 95.00
Location
SL. No. Item Deff from Span (L/8) Span (L/4) Span Span
support (3L/8) (L/2)
t-m t-m t-m t-m t-m
Bending Moments
1 Stage 1 Loading 76.1 146.0 258.0 334.0 355.0
Location
SL. No. Item Deff from Span (L/8) Span (L/4) Span Span
support (3L/8) (L/2)
t-m t-m t-m t-m t-m
Bending Moments
1 Stage 1 Loading 76.1 146.0 258.0 334.0 355.0
From STAAD
Output
5 SIDL W/C ( Moment) 16.8 31.6 55.1 69.4 71.5
From STAAD
Output
5 SIDL W/C ( Moment) 8.0 7.0 4.4 1.6 0.9
Cable No 2
Cable No 4
Fck 50 Mpa
Modulus of Elasticity (Conc) 14th Day 3.30E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 90th Day 3.51E+06 t/m2
Modulus of Elasticity (Strands) 1.95E+07 t/m2
Total Relaxation Loss at service condition (cl: 6.3.6 IRC 112) = 3 x (1000 hr. value)
Initial force after Friction, slip & ES loss = 898.46 t
Percentage of Initial force = 0.6854 UTS
Relaxation Loss at 1000hr. for low relaxation steel = 2.32 % of initial stress
Relaxation Loss at 1000hr. for low relaxation steel = 5.65 t/Cable
Immediate Loss i.e 1 hr. of stressing (Table 6.3 IRC:112) = 34 % of Total Loss
7 - 28 days Loss = 90 % of Total Loss
28 - 90 days Loss = 100 % of Total Loss
90 - a days Loss = 200 % of Total Loss
Immediate Loss i.e 1 hr. of stressing = 1.92 t/Cable
7 - 28 days Loss = 3.17 t/Cable
28 - 90 days Loss = 0.57 t/Cable
90 - a days Loss = 11.30 t/Cable
Strain due to differential shrinkage and creep 1.00E-04
Reduction factor due to differential creep 0.43
PSC BEAM AND RC SLAB STRUCTURE OF SIMPLY SUPPORTED SPAN
(OUTER GIRDER)
Item Unit 1 2 3 4 5
MEMBER NO
distance of Section from left support m 2.000 4.000 8.973 12.974 17.175
SIDL
Moments Tm 47.0 85.3 137.4 152.3 132.3
Shear T 21.0 16.0 8.6 5.6 11.0
Live Load (Sagging) (max Moment Case & max Positive Shear case)
Moments Tm 94.3 173.5 281.7 350.8 378.0
Shear T 48.0 41.6 32.5 24.8 29.7
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Area of the section m 1.8142 1.38808125 0.96196 0.961963 0.9619625
Depth of the section m 2.500 2.500 2.500 2.500 2.500
CG of section from bottom m 1.2752406 1.255953054 1.23667 1.236665 1.236665476
4
Inertia of section m 0.9769032 0.838329327 0.69976 0.699755 0.699755494
3
Top Section Modulus m 0.7976 0.6739 0.5539 0.5539 0.5539
3
Bottom Section Modulus m 0.7661 0.6675 0.5658 0.5658 0.5658
2
Area of the section m 2.6482 2.22208125 1.79596 1.795963 1.7959625
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.788899142 1.87905 1.879051 1.879051379
4
Inertia of section m 2.0141187 1.786355282 1.55859 1.558592 1.558591853
3
Top Section Modulus m 1.9343 1.8782 1.8103 1.8103 1.8103
3
Bottom Section Modulus m 1.1856 0.9986 0.8295 0.8295 0.8295
2
Area of the section m 2.6482 2.22208125 1.79596 1.795963 1.7959625
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.788899142 1.87905 1.879051 1.879051379
4
Inertia of section m 2.0141187 1.786355282 1.55859 1.558592 1.558591853
3
Top Section Modulus m 1.9343 1.8782 1.8103 1.8103 1.8103
3
Bottom Section Modulus m 1.1856 0.9986 0.8295 0.8295 0.8295
For Cable 1b
No of Tendons of 19T13 1.00 1.00 1.00 1.00 1.00
Prestressing Force (P1) T 239.82 240.90 253.17 255.80 253.66
CG of Tendons from Bottom m 0.6629 0.4950 0.1203 0.1200 0.1200
Eccentricity of Tendons m 0.6123 0.7609 1.1163 1.1167 1.1167
Prestressing Factor (Top) -0.2165 -0.4088 -0.9759 -0.9765 -0.9765
Prestressing Factor (Bottom) 1.3505 1.8604 3.0124 3.0130 3.0130
For Cable 1c
No of Tendons of 19T13 1.00 1.00 1.00 1.00 1.00
Prestressing Force (P1) T 245.44 246.52 249.19 257.76 258.28
CG of Tendons from Bottom m 1.0200 0.7996 0.2516 0.1200 0.1200
Eccentricity of Tendons m 0.2552 0.4563 0.9851 1.1167 1.1167
Prestressing Factor (Top) 0.2313 0.0433 -0.7389 -0.9765 -0.9765
Prestressing Factor (Bottom) 0.8843 1.4041 2.7805 3.0130 3.0130
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
For Cable 1d
No of Tendons of 19T13 0.68 0.68 0.68 0.68 0.68
Prestressing Force (P1) T 168.71 169.45 171.28 177.24 176.66
CG of Tendons from Bottom m 1.4170 1.1929 0.6355 0.3000 0.3000
Eccentricity of Tendons m -0.1418 0.0631 0.6011 0.9367 0.9367
Prestressing Factor (Top) 0.7289 0.6268 -0.0457 -0.6515 -0.6515
Prestressing Factor (Bottom) 0.3662 0.8150 2.1019 2.6949 2.6949
For Cable 1e
No of Tendons of 19T13 0.00 0.00 0.00 0.00 0.00
Prestressing Force (P1) T 0.00 0.00 0.00 0.00 0.00
CG of Tendons from Bottom m 0.0000 0.0000 0.0000 0.0000 0.0000
Eccentricity of Tendons m 1.2752 1.2560 1.2367 1.2367 1.2367
Prestressing Factor (Top) -1.0476 -1.1434 -1.1931 -1.1931 -1.1931
Prestressing Factor (Bottom) 2.2159 2.6020 3.2251 3.2251 3.2251
Dead Load Moments - Ist stage Tm 76.10 146.00 258.00 334.00 355.00
Eloss of cable (1a) for stressing of (1a) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1a) for stressing of (1b) T 6.04 6.04 6.04 6.04 6.04
Eloss of cable (1a) for stressing of (1c) T 5.50 5.50 5.50 5.50 5.50
Eloss of cable (1a) for stressing of (1d) T 2.98 2.98 2.98 2.98 2.98
Eloss of cable (1a) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1b) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1c) T 5.38 5.38 5.38 5.38 5.38
Eloss of cable (1b) for stressing of (1d) T 2.99 2.99 2.99 2.99 2.99
Eloss of cable (1b) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1c) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1d) T 2.94 2.94 2.94 2.94 2.94
Eloss of cable (1c) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1d) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1e) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Total Eloss for Stage 1 cables T 25.83 25.83 25.83 25.83 25.83
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Stress at CG of cable 1a T/m 694.50 990.24 1610.89 1660.84 1621.88
2
Stress at CG of cable 1b T/m 587.42 847.59 1610.66 1660.84 1621.88
2
Stress at CG of cable 1c T/m 489.34 728.40 1516.41 1660.84 1621.88
2
Stress at CG of cable 1d T/m 380.33 574.54 1240.73 1526.13 1493.12
2
Stress at CG of cable 1e T/m 769.46 1041.28 1697.05 1750.64 1707.72
2
Stress at CG of Stage 1 Cables T/m 518.13 753.06 1429.98 1541.35 1503.53
2
T/m
2
Average Stress at CG of Stage 1 Cables T/m 1254.65
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Dead Load Moments -IInd stage Tm 77.48 145.38 256.78 332.07 353.24
Stress Due to dead load
2
Top T/m 97.14 215.73 463.59 599.51 637.74
2
Bottom T/m -101.14 -217.80 -453.80 -586.85 -624.27
2
Stress at CG of GR I Tendons T/m -37.70 -111.62 -361.68 -513.88 -546.67
2
Stress at CG of GR II Tendons T/m 3671.93 -216.06 -450.13 -582.11 -619.23
Stresses due to C + S + R
2
Top T/m 0.84 1.62 3.15 3.64 3.64
2
T/m -0.15 0.17 0.84 1.20 1.20
2
Bottom T/m -10.53 -14.97 -23.17 -24.25 -24.25
2
Stress at CG of Tendon I T/m 467.23 616.29 999.63 938.50 864.64
2
Average Stress at CG of Tendon GRI T/m 841.27
2
Stress at CG of Gr I Tendons T/m -20.98 -56.18 -143.52 -168.59 -146.45
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Stress at CG of Tendon I T/m 373.71 446.33 646.44 540.81 489.08
2
Avg stress for each segment T/m 410.02 546.39 593.63 514.94 0.00
Segment length m 2.00 4.97 4.00 4.20 -17.18
length m 15.18
2
Average Stress at CG of Tendon GRI T/m 532.16
Moment Due to Live Load (Sagging) Tm 94.32 173.46 281.65 350.76 377.96
Stresses due to Live Load (Sagging)
2
Top of Deck Slab T/m 48.76 92.35 155.58 193.76 208.78
2
Top of Girder T/m 37.52 69.05 112.21 139.74 150.58
2
Bottom T/m -79.55 -173.71 -339.56 -422.88 -455.67
Stress at service with differential shrinkage and differential creep effect (without Live Load)
2
Top of Deck Slab T/m 19.52 36.46 61.46 60.70 45.58
2
Top of Girder T/m 246.68 407.35 605.17 766.52 846.83
2
Bottom T/m 433.47 458.97 651.05 526.02 465.64
Stress at service with differential shrinkage and differential creep effect (with 75% Live Load)
Top of Deck Slab T/m2 56.09 105.73 178.15 206.02 202.16
2
Top of Girder T/m 274.82 459.13 689.33 871.32 959.77
2
Bottom T/m 373.81 328.69 396.38 208.85 123.89
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Stress at Service with 75% Live Load (sag) + Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m 265.46 315.10 385.40 413.00 409.15
2
Top of Girder T/m 144.69 329.01 554.97 736.75 825.19
2
Bottom T/m 532.61 487.49 528.95 341.71 256.74
Stress at Service with 100% Live Load (sag) + 60% Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m 193.90 254.44 341.40 378.65 378.55
2
Top of Girder T/m 206.12 398.32 636.77 825.52 916.67
2
Bottom T/m 449.20 380.55 391.03 182.84 89.68
Stress at Service with 75% Live Load (sag) + 50% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m 160.78 210.41 281.78 309.51 305.66
2
Top of Girder T/m 209.76 394.07 622.15 804.04 892.48
2
Bottom T/m 453.21 408.09 462.66 275.28 190.31
Stress at Service with 20% Live Load (sag) + 60% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m 154.90 180.56 216.93 223.64 211.53
2
Top of Girder T/m 176.11 343.08 547.00 713.72 796.20
2
Bottom T/m 512.84 519.51 662.68 521.15 454.22
Stress at Service with 100% Live Load (sag) +60 % Temp Fall (RARE COMBINATION)
2
Top of Deck Slab T/m -112.84 -52.31 27.26 178.26 178.16
2
Top of Girder T/m 230.08 422.28 654.22 941.66 1032.81
2
Bottom T/m 288.35 219.69 232.83 26.33 -66.83
Stress at Service with 75% Live Load (sag) + 50% Temp Fall (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -94.85 -45.21 20.00 142.52 138.66
2
Top of Girder T/m 229.72 414.04 636.70 900.82 989.27
2
Bottom T/m 319.16 274.05 330.83 144.85 59.89
Stress at Service with 20% Live Load (sag) + 60% TempFall (FREQUENT COMBINATION)
Top of Deck Slab T/m2 -151.85 -126.19 -97.20 23.25 11.14
2
Top of Girder T/m 200.07 367.04 564.45 829.86 912.35
2
Bottom T/m 351.99 358.66 504.48 364.64 297.70
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Minimum Stress = -120.27 t/m < -350 t/m2
After Stage 2
2 2
Maximum Stress = 1073.89 t/m < 2400 t/m
2 2
Minimum Stress = 229.81 t/m < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (without Live Load)
2 2
Maximum Stress = 846.83 t/m < 2400 t/m
2
Minimum Stress = 246.68 < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (with Live Load)
2 2
Maximum Stress = 997.41 t/m < 2400 t/m
2 2
Minimum Stress = 9.97 t/m < 2400 t/m
Stress at Service with Live Load (sag) + Temp Rise (FREQUENT COMBINATION)
2
Maximum Stress = 892.48 t/m < 1800 t/m2
2 2
Minimum Stress = 176.11 t/m < -350 t/m
2 2
Minimum Stress = 59.89 t/m < -350 t/m
Stress at Service with Live Load (sag) + Temp Rise (Rare COMBINATION)
2 2
Maximum Stress = 916.67 t/m < 2400 t/m
2 2
Minimum Stress = 89.68 t/m < -350 t/m
Table 5.1.2 Ultimate forces at Sections:- Ultimate Force = 1.35xDL+1.75xSIDL+1.5xLL
fb = 41.44 N/mm2
2Ypo = 345 mm
Ypo/Yo = 0.69
Fbst/Pk = 0.124
Fbst = 0.12x2196.05
272.31 kN
754.21856 mm2
16 dia helix with 13 turns in 2Y0 region provided (Ast) 2613.805 mm2
Check for shear in flanged portion As per IRC: 112-2011 Clause 10.3.5.
Diffrence in stress (t/m2) 60.54
Length Ϫx (m) 2
θf 30
cotθf 1.73
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 5428.672 mm /m
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 3619.115 mm /m
Fck 50 Mpa
Modulus of Elasticity (Conc) 14th Day 3.30E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 90th Day 3.51E+06 t/m2
Modulus of Elasticity (Strands) 1.95E+07 t/m2
Total Relaxation Loss at service condition (cl: 6.3.6 IRC 112) = 3 x (1000 hr. value)
Initial force after Friction, slip & ES loss = 893.05 t
Percentage of Initial force = 0.6813 UTS
Relaxation Loss at 1000hr. for low relaxation steel = 2.27 % of initial stress
Relaxation Loss at 1000hr. for low relaxation steel = 5.49 t/Cable
Immediate Loss i.e 1 hr. of stressing (Table 6.3 IRC:112) = 34 % of Total Loss
7 - 28 days Loss = 90 % of Total Loss
28 - 90 days Loss = 100 % of Total Loss
90 - a days Loss = 200 % of Total Loss
Immediate Loss i.e 1 hr. of stressing = 1.87 t/Cable
7 - 28 days Loss = 3.08 t/Cable
28 - 90 days Loss = 0.55 t/Cable
90 - a days Loss = 10.99 t/Cable
Strain due to differential shrinkage and creep 1.00E-04
Reduction factor due to differential creep 0.43
PSC BEAM AND RC SLAB STRUCTURE OF SIMPLY SUPPORTED SPAN
(OUTER GIRDER)
Item Unit 1 2 3 4 5
MEMBER NO
distance of Section from left support m 2.000 4.000 8.973 12.974 17.175
SIDL
Moments Tm 47.0 85.3 137.4 152.3 132.3
Shear T 21.0 16.0 8.6 5.6 11.0
Live Load (Sagging) (max Moment Case & max Positive Shear case)
Moments Tm 94.3 173.5 281.7 350.8 378.0
Shear T 48.0 41.6 32.5 24.8 29.7
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Area of the section m 1.8142 1.38808125 0.96196 0.961963 0.9619625
Depth of the section m 2.500 2.500 2.500 2.500 2.500
CG of section from bottom m 1.2752406 1.255953054 1.23667 1.236665 1.236665476
4
Inertia of section m 0.9769032 0.838329327 0.69976 0.699755 0.699755494
3
Top Section Modulus m 0.7976 0.6739 0.5539 0.5539 0.5539
3
Bottom Section Modulus m 0.7661 0.6675 0.5658 0.5658 0.5658
2
Area of the section m 2.6482 2.22208125 1.79596 1.795963 1.7959625
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.788899142 1.87905 1.879051 1.879051379
4
Inertia of section m 2.0141187 1.786355282 1.55859 1.558592 1.558591853
3
Top Section Modulus m 1.9343 1.8782 1.8103 1.8103 1.8103
3
Bottom Section Modulus m 1.1856 0.9986 0.8295 0.8295 0.8295
2
Area of the section m 2.6482 2.22208125 1.79596 1.795963 1.7959625
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.788899142 1.87905 1.879051 1.879051379
4
Inertia of section m 2.0141187 1.786355282 1.55859 1.558592 1.558591853
3
Top Section Modulus m 1.9343 1.8782 1.8103 1.8103 1.8103
3
Bottom Section Modulus m 1.1856 0.9986 0.8295 0.8295 0.8295
For Cable 1b
No of Tendons of 19T13 1.00 1.00 1.00 1.00 1.00
Prestressing Force (P1) T 239.82 240.90 253.17 255.80 253.66
CG of Tendons from Bottom m 0.6629 0.4950 0.1203 0.1200 0.1200
Eccentricity of Tendons m 0.6123 0.7609 1.1163 1.1167 1.1167
Prestressing Factor (Top) -0.2165 -0.4088 -0.9759 -0.9765 -0.9765
Prestressing Factor (Bottom) 1.3505 1.8604 3.0124 3.0130 3.0130
For Cable 1c
No of Tendons of 19T13 1.00 1.00 1.00 1.00 1.00
Prestressing Force (P1) T 245.44 246.52 249.19 257.76 258.28
CG of Tendons from Bottom m 1.0200 0.7996 0.2516 0.1200 0.1200
Eccentricity of Tendons m 0.2552 0.4563 0.9851 1.1167 1.1167
Prestressing Factor (Top) 0.2313 0.0433 -0.7389 -0.9765 -0.9765
Prestressing Factor (Bottom) 0.8843 1.4041 2.7805 3.0130 3.0130
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
For Cable 1d
No of Tendons of 19T13 0.68 0.68 0.68 0.68 0.68
Prestressing Force (P1) T 168.71 169.45 171.28 177.24 176.66
CG of Tendons from Bottom m 1.4170 1.1929 0.6355 0.3000 0.3000
Eccentricity of Tendons m -0.1418 0.0631 0.6011 0.9367 0.9367
Prestressing Factor (Top) 0.7289 0.6268 -0.0457 -0.6515 -0.6515
Prestressing Factor (Bottom) 0.3662 0.8150 2.1019 2.6949 2.6949
For Cable 1e
No of Tendons of 19T13 0.00 0.00 0.00 0.00 0.00
Prestressing Force (P1) T 0.00 0.00 0.00 0.00 0.00
CG of Tendons from Bottom m 0.0000 0.0000 0.0000 0.0000 0.0000
Eccentricity of Tendons m 1.2752 1.2560 1.2367 1.2367 1.2367
Prestressing Factor (Top) -1.0476 -1.1434 -1.1931 -1.1931 -1.1931
Prestressing Factor (Bottom) 2.2159 2.6020 3.2251 3.2251 3.2251
Dead Load Moments - Ist stage Tm 76.10 146.00 258.00 334.00 355.00
Eloss of cable (1a) for stressing of (1a) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1a) for stressing of (1b) T 7.34 7.34 7.34 7.34 7.34
Eloss of cable (1a) for stressing of (1c) T 6.65 6.65 6.65 6.65 6.65
Eloss of cable (1a) for stressing of (1d) T 3.59 3.59 3.59 3.59 3.59
Eloss of cable (1a) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1b) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1c) T 6.51 6.51 6.51 6.51 6.51
Eloss of cable (1b) for stressing of (1d) T 3.61 3.61 3.61 3.61 3.61
Eloss of cable (1b) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1c) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1d) T 3.54 3.54 3.54 3.54 3.54
Eloss of cable (1c) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1d) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1e) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Total Eloss for Stage 1 cables T 31.24 31.24 31.24 31.24 31.24
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Stress at CG of cable 1a T/m 859.07 1243.54 2045.52 2133.38 2093.21
2
Stress at CG of cable 1b T/m 723.07 1057.19 2045.21 2133.38 2093.21
2
Stress at CG of cable 1c T/m 598.52 901.48 1920.36 2133.38 2093.21
2
Stress at CG of cable 1d T/m 460.06 700.47 1555.16 1951.17 1917.07
2
Stress at CG of cable 1e T/m 954.28 1310.22 2159.66 2254.85 2210.64
2
Stress at CG of Stage 1 Cables T/m 636.91 938.25 1815.34 1984.58 1945.59
2
T/m
2
Average Stress at CG of Stage 1 Cables T/m 1599.94
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Dead Load Moments -IInd stage Tm 77.48 145.38 256.78 332.07 353.24
Stress Due to dead load
2
Top T/m 97.14 215.73 463.59 599.51 637.74
2
Bottom T/m -101.14 -217.80 -453.80 -586.85 -624.27
2
Stress at CG of GR I Tendons T/m -37.70 -111.62 -361.68 -513.88 -546.67
2
Stress at CG of GR II Tendons T/m 3671.93 -216.06 -450.13 -582.11 -619.23
Stresses due to C + S + R
2
Top T/m 1.07 2.06 4.00 4.63 4.63
2
T/m -0.20 0.21 1.07 1.52 1.52
2
Bottom T/m -13.37 -19.02 -29.44 -30.81 -30.81
2
Stress at CG of Tendon I T/m 584.06 798.45 1379.40 1375.62 1300.59
2
Average Stress at CG of Tendon GRI T/m 1181.58
2
Stress at CG of Gr I Tendons T/m -20.98 -56.18 -143.52 -168.59 -146.45
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Stress at CG of Tendon I T/m 475.43 604.78 982.53 930.20 877.29
2
Avg stress for each segment T/m 540.11 793.66 956.37 903.75 0.00
Segment length m 2.00 4.97 4.00 4.20 -17.18
length m 15.18
2
Average Stress at CG of Tendon GRI T/m 833.62
Moment Due to Live Load (Sagging) Tm 94.32 173.46 281.65 350.76 377.96
Stresses due to Live Load (Sagging)
2
Top of Deck Slab T/m 48.76 92.35 155.58 193.76 208.78
2
Top of Girder T/m 37.52 69.05 112.21 139.74 150.58
2
Bottom T/m -79.55 -173.71 -339.56 -422.88 -455.67
Stress at service with differential shrinkage and differential creep effect (without Live Load)
2
Top of Deck Slab T/m 21.49 40.32 68.94 69.35 54.23
2
Top of Girder T/m 248.35 381.21 493.25 620.84 701.55
2
Bottom T/m 582.26 677.30 1037.15 950.48 888.81
Stress at service with differential shrinkage and differential creep effect (with 75% Live Load)
Top of Deck Slab T/m2 58.06 109.58 185.63 214.67 210.82
2
Top of Girder T/m 276.49 433.00 577.40 725.65 814.48
2
Bottom T/m 522.60 547.02 782.48 633.32 547.06
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
Stress at Service with 75% Live Load (sag) + Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m 267.43 318.95 392.88 421.66 417.81
2
Top of Girder T/m 146.36 302.88 443.05 591.08 679.91
2
Bottom T/m 681.40 705.82 915.05 766.17 679.91
Stress at Service with 100% Live Load (sag) + 60% Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m 195.87 258.29 348.87 387.30 387.21
2
Top of Girder T/m 207.79 372.19 524.84 679.84 771.39
2
Bottom T/m 598.00 598.88 777.13 607.31 512.85
Stress at Service with 75% Live Load (sag) + 50% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m 162.74 214.27 289.25 318.16 314.31
2
Top of Girder T/m 211.42 367.94 510.23 658.36 747.20
2
Bottom T/m 602.00 626.42 848.76 699.74 613.48
Stress at Service with 20% Live Load (sag) + 60% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m 156.86 184.41 224.41 232.29 220.18
2
Top of Girder T/m 177.77 316.95 435.07 568.05 650.92
2
Bottom T/m 661.64 737.84 1048.78 945.61 877.39
Stress at Service with 100% Live Load (sag) +60 % Temp Fall (RARE COMBINATION)
2
Top of Deck Slab T/m -110.88 -48.45 34.74 186.91 186.81
2
Top of Girder T/m 231.75 396.15 542.30 795.99 887.53
2
Bottom T/m 437.14 438.02 618.93 450.80 356.34
Stress at Service with 75% Live Load (sag) + 50% Temp Fall (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -92.88 -41.36 27.48 151.17 147.32
2
Top of Girder T/m 231.39 387.90 524.77 755.15 843.98
2
Bottom T/m 467.96 492.38 716.93 569.32 483.06
Stress at Service with 20% Live Load (sag) + 60% TempFall (FREQUENT COMBINATION)
Top of Deck Slab T/m2 -149.89 -122.34 -89.72 31.90 19.79
2
Top of Girder T/m 201.73 340.91 452.53 684.19 767.07
2
Bottom T/m 500.78 576.99 890.58 789.10 720.88
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 8.973 12.974 17.175
2
Minimum Stress = -275.81 t/m < -350 t/m2
After Stage 2
2 2
Maximum Stress = 1515.01 t/m < 2400 t/m
2 2
Minimum Stress = 231.86 t/m < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (without Live Load)
2 2
Maximum Stress = 1037.15 t/m < 2400 t/m
2
Minimum Stress = 248.35 < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (with Live Load)
2 2
Maximum Stress = 852.13 t/m < 2400 t/m
2 2
Minimum Stress = 285.87 t/m < 2400 t/m
Stress at Service with Live Load (sag) + Temp Rise (FREQUENT COMBINATION)
2
Maximum Stress = 1048.78 t/m < 1800 t/m2
2 2
Minimum Stress = 177.77 t/m < -350 t/m
2 2
Minimum Stress = 201.73 t/m < -350 t/m
Stress at Service with Live Load (sag) + Temp Rise (Rare COMBINATION)
2 2
Maximum Stress = 915.05 t/m < 2400 t/m
2 2
Minimum Stress = 146.36 t/m < -350 t/m
Table 5.1.2 Ultimate forces at Sections:- Ultimate Force = 1.35xDL+1.75xSIDL+1.5xLL
fb = 41.44 N/mm2
2Ypo = 345 mm
Ypo/Yo = 0.69
Fbst/Pk = 0.124
Fbst = 0.12x2141.92
265.60 kN
735.62758 mm2
16 dia helix with 13 turns in 2Y0 region provided (Ast) 2613.805 mm2
Check for shear in flanged portion As per IRC: 112-2011 Clause 10.3.5.
Diffrence in stress (t/m2) 62.42
Length Ϫx (m) 2
θf 30
cotθf 1.73
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 5428.672 mm /m
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 3619.115 mm /m
Cable No 2
Cable No 4
Fck 50 Mpa
Modulus of Elasticity (Conc) 14th Day 3.30E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 90th Day 3.51E+06 t/m2
Modulus of Elasticity (Strands) 1.95E+07 t/m2
Total Relaxation Loss at service condition (cl: 6.3.6 IRC 112) = 3 x (1000 hr. value)
Initial force after Friction, slip & ES loss = 825.82 t
Percentage of Initial force = 0.6891 UTS
Relaxation Loss at 1000hr. for low relaxation steel = 2.36 % of initial stress
Relaxation Loss at 1000hr. for low relaxation steel = 5.79 t/Cable
Immediate Loss i.e 1 hr. of stressing (Table 6.3 IRC:112) = 34 % of Total Loss
7 - 28 days Loss = 90 % of Total Loss
28 - 90 days Loss = 100 % of Total Loss
90 - a days Loss = 200 % of Total Loss
Immediate Loss i.e 1 hr. of stressing = 1.97 t/Cable
7 - 28 days Loss = 3.24 t/Cable
28 - 90 days Loss = 0.58 t/Cable
90 - a days Loss = 11.59 t/Cable
Strain due to differential shrinkage and creep 1.00E-04
Reduction factor due to differential creep 0.43
PSC BEAM AND RC SLAB STRUCTURE OF SIMPLY SUPPORTED SPAN
(INNER GIRDER)
Item Unit 1 2 3 4 5
MEMBER NO
distance of Section from left support m 2.000 4.000 6.090 12.180 16.970
SIDL
Moments Tm 23.5 42.1 87.0 141.3 191.3
Shear T 11.2 10.6 11.4 11.8 10.7
Live Load (Sagging) (max Moment Case & max Positive Shear case)
Moments Tm 129.2 203.6 292.8 318.8 293.9
Shear T 50.0 40.9 28.8 31.1 41.4
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Area of the section m 1.8142 1.38808125 0.96196 0.961963 0.9619625
Depth of the section m 2.500 2.500 2.500 2.500 2.500
CG of section from bottom m 1.2752406 1.255953054 1.23667 1.236665 1.236665476
4
Inertia of section m 0.9769032 0.838329327 0.69976 0.699755 0.699755494
3
Top Section Modulus m 0.7976 0.6739 0.5539 0.5539 0.5539
3
Bottom Section Modulus m 0.7661 0.6675 0.5658 0.5658 0.5658
2
Area of the section m 2.51 2.084 1.658 1.658 1.658
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.757873453 1.817 1.817 1.817
4
Inertia of section m 1.89 1.683 1.476 1.476 1.476
3
Top Section Modulus m 1.8151 1.7136 1.5991 1.5991 1.5991
3
Bottom Section Modulus m 1.1126 0.9574 0.8123 0.8123 0.8123
2
Area of the section m 2.51 2.084 1.658 1.658 1.658
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.757873453 1.817 1.817 1.817
4
Inertia of section m 1.89 1.683 1.476 1.476 1.476
3
Top Section Modulus m 1.8151 1.7136 1.5991 1.5991 1.5991
3
Bottom Section Modulus m 1.1126 0.9574 0.8123 0.8123 0.8123
For Cable 1b
No of Tendons of 19T13 0.95 0.95 0.95 0.95 0.95
Prestressing Force (P1) T 227.20 228.23 239.84 242.34 240.31
CG of Tendons from Bottom m 0.6629 0.4950 0.1203 0.1200 0.1200
Eccentricity of Tendons m 0.6123 0.7609 1.1163 1.1167 1.1167
Prestressing Factor (Top) -0.2165 -0.4088 -0.9759 -0.9765 -0.9765
Prestressing Factor (Bottom) 1.3505 1.8604 3.0124 3.0130 3.0130
For Cable 1c
No of Tendons of 19T13 0.95 0.95 0.95 0.95 0.95
Prestressing Force (P1) T 232.52 233.54 236.08 244.20 244.69
CG of Tendons from Bottom m 1.0200 0.7996 0.2516 0.1200 0.1200
Eccentricity of Tendons m 0.2552 0.4563 0.9851 1.1167 1.1167
Prestressing Factor (Top) 0.2313 0.0433 -0.7389 -0.9765 -0.9765
Prestressing Factor (Bottom) 0.8843 1.4041 2.7805 3.0130 3.0130
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
For Cable 1d
No of Tendons of 19T13 0.53 0.53 0.53 0.53 0.53
Prestressing Force (P1) T 129.77 130.34 131.75 136.34 135.89
CG of Tendons from Bottom m 1.4170 1.1929 0.6355 0.3000 0.3000
Eccentricity of Tendons m -0.1418 0.0631 0.6011 0.9367 0.9367
Prestressing Factor (Top) 0.7289 0.6268 -0.0457 -0.6515 -0.6515
Prestressing Factor (Bottom) 0.3662 0.8150 2.1019 2.6949 2.6949
For Cable 1e
No of Tendons of 19T13 0.00 0.00 0.00 0.00 0.00
Prestressing Force (P1) T 0.00 0.00 0.00 0.00 0.00
CG of Tendons from Bottom m 0.0000 0.0000 0.0000 0.0000 0.0000
Eccentricity of Tendons m 1.2752 1.2560 1.2367 1.2367 1.2367
Prestressing Factor (Top) -1.0476 -1.1434 -1.1931 -1.1931 -1.1931
Prestressing Factor (Bottom) 2.2159 2.6020 3.2251 3.2251 3.2251
Dead Load Moments - Ist stage Tm 76.10 146.00 258.00 334.00 355.00
Eloss of cable (1a) for stressing of (1a) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1a) for stressing of (1b) T 5.67 5.67 5.67 5.67 5.67
Eloss of cable (1a) for stressing of (1c) T 5.26 5.26 5.26 5.26 5.26
Eloss of cable (1a) for stressing of (1d) T 2.39 2.39 2.39 2.39 2.39
Eloss of cable (1a) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1b) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1c) T 5.20 5.20 5.20 5.20 5.20
Eloss of cable (1b) for stressing of (1d) T 2.39 2.39 2.39 2.39 2.39
Eloss of cable (1b) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1c) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1d) T 2.36 2.36 2.36 2.36 2.36
Eloss of cable (1c) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1d) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1e) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Total Eloss for Stage 1 cables T 23.27 23.27 23.27 23.27 23.27
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Stress at CG of cable 1a T/m 644.45 908.27 1453.05 1476.94 1438.51
2
Stress at CG of cable 1b T/m 542.73 776.76 1452.84 1476.94 1438.51
2
Stress at CG of cable 1c T/m 449.56 666.87 1368.94 1476.94 1438.51
2
Stress at CG of cable 1d T/m 346.01 525.02 1123.53 1360.33 1327.79
2
Stress at CG of cable 1e T/m 715.66 955.33 1529.75 1554.68 1512.32
2
Stress at CG of Stage 1 Cables T/m 482.69 695.85 1296.38 1370.45 1332.96
2
T/m
2
Average Stress at CG of Stage 1 Cables T/m 1192.76
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Dead Load Moments -IInd stage Tm 58.96 110.96 197.50 258.56 279.55
Stress Due to dead load
2
Top T/m 73.92 164.65 356.56 466.80 504.69
2
Bottom T/m -76.96 -166.23 -349.03 -456.95 -494.04
2
Stress at CG of GR I Tendons T/m -30.06 -88.02 -282.10 -402.10 -434.76
2
Stress at CG of GR II Tendons T/m 2643.11 -164.91 -346.21 -453.25 -490.04
Stresses due to C + S + R
2
Top T/m 0.96 1.69 3.24 3.71 3.71
2
T/m -0.03 0.29 1.08 1.42 1.42
2
Bottom T/m -10.42 -14.31 -21.48 -22.40 -22.40
2
Stress at CG of Tendon I T/m 439.79 584.11 952.65 890.96 818.20
2
Average Stress at CG of Tendon GRI T/m 824.12
2
Stress at CG of Gr I Tendons T/m -11.46 -29.19 -93.12 -159.74 -216.26
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Stress at CG of Tendon I T/m 355.38 444.36 662.74 517.68 388.39
2
Avg stress for each segment T/m 399.87 553.55 590.21 453.03 0.00
Segment length m 2.00 2.09 6.09 4.79 -16.97
length m 14.97
2
Average Stress at CG of Tendon GRI T/m 515.77
Moment Due to Live Load (Sagging) Tm 129.23 203.58 292.80 318.79 293.93
Stresses due to Live Load (Sagging)
2
Top of Deck Slab T/m 71.20 118.80 183.10 199.35 183.81
2
Top of Girder T/m 54.79 89.77 135.49 147.51 136.01
2
Bottom T/m -116.16 -212.64 -360.45 -392.44 -361.84
Stress at service with differential shrinkage and differential creep effect (without Live Load)
Top of Deck Slab T/m2 11.13 18.85 43.99 69.49 96.91
2
Top of Girder T/m 191.72 320.82 488.82 661.21 770.03
2
Bottom T/m 429.20 482.60 680.96 508.62 364.31
Stress at service with differential shrinkage and differential creep effect (with 75% Live Load)
2
Top of Deck Slab T/m 64.53 107.96 181.31 219.01 234.77
2
Top of Girder T/m 232.81 388.14 590.44 771.84 872.04
2
Bottom T/m 342.08 323.12 410.63 214.29 92.93
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Stress at Service with 75% Live Load (sag) + Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m -147.88 -104.45 390.99 428.68 444.45
2
Top of Girder T/m 360.41 515.74 458.09 639.49 739.68
2
Bottom T/m 186.07 167.11 540.82 344.48 223.12
Stress at Service with 100% Live Load (sag) + 60% Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m -45.12 10.21 352.90 394.65 406.53
2
Top of Girder T/m 323.06 487.15 544.90 729.31 826.63
2
Bottom T/m 219.44 176.35 398.63 194.30 80.58
Stress at Service with 75% Live Load (sag) + 50% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -41.68 1.75 286.15 323.84 339.61
2
Top of Girder T/m 296.61 451.94 524.26 705.67 805.86
2
Bottom T/m 264.08 245.11 475.72 279.39 158.02
Stress at Service with 20% Live Load (sag) + 60% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -102.07 -84.83 206.42 235.17 259.48
2
Top of Girder T/m 279.23 415.33 436.51 611.30 717.82
2
Bottom T/m 312.36 346.46 686.99 508.25 370.05
Stress at Service with 100% Live Load (sag) +60 % Temp Fall (RARE COMBINATION)
2
Top of Deck Slab T/m -95.63 -40.30 39.42 81.17 93.05
2
Top of Girder T/m 195.12 359.20 563.01 747.42 844.73
2
Bottom T/m 245.65 202.56 241.06 36.73 -76.99
Stress at Service with 75% Live Load (sag) + 50% Temp Fall (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -83.77 -40.34 24.92 62.61 78.38
2
Top of Girder T/m 189.99 345.32 539.35 720.76 820.95
2
Bottom T/m 285.92 266.95 344.42 148.08 26.71
Stress at Service with 20% Live Load (sag) + 60% TempFall (FREQUENT COMBINATION)
Top of Deck Slab T/m2 -152.59 -135.34 -107.06 -78.31 -53.99
2
Top of Girder T/m 151.29 287.38 454.61 629.41 735.92
2
Bottom T/m 338.57 372.67 529.42 350.68 212.48
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Minimum Stress = -68.20 t/m < -350 t/m2
After Stage 2
2 2
Maximum Stress = 1028.11 t/m < 2400 t/m
2 2
Minimum Stress = 182.26 t/m < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (without Live Load)
2 2
Maximum Stress = 770.03 t/m < 2400 t/m
2
Minimum Stress = 191.72 < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (with Live Load)
2 2
Maximum Stress = 906.04 t/m < 2400 t/m
2 2
Minimum Stress = 2.47 t/m < 2400 t/m
Stress at Service with Live Load (sag) + Temp Rise (FREQUENT COMBINATION)
2
Maximum Stress = 805.86 t/m < 1800 t/m2
2 2
Minimum Stress = 158.02 t/m < -350 t/m
2 2
Minimum Stress = 26.71 t/m < -350 t/m
Stress at Service with Live Load (sag) + Temp Rise (Rare COMBINATION)
2 2
Maximum Stress = 826.63 t/m < 2400 t/m
2 2
Minimum Stress = 80.58 t/m < -350 t/m
2 2
Minimum Stress = -76.99 t/m < -350 t/m
Table 5.1.2 Ultimate forces at Sections:- Ultimate Force = 1.35xDL+1.75xSIDL+1.5xLL
fb = 41.44 N/mm2
2Ypo = 345 mm
Ypo/Yo = 0.69
Fbst/Pk = 0.124
Fbst = 0.12x2092.46
259.46 kN
718.63874 mm2
16 dia helix with 13 turns in 2Y0 region provided (Ast) 2613.805 mm2
Check for shear in flanged portion As per IRC: 112-2011 Clause 10.3.5.
Diffrence in stress (t/m2) 55.33
Length Ϫx (m) 2
θf 30
cotθf 1.73
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 5428.672 mm /m
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 3619.115 mm /m
Fck 50 Mpa
Modulus of Elasticity (Conc) 14th Day 3.30E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 28th Day 3.40E+06 t/m2
Modulus of Elasticity (Conc) 90th Day 3.51E+06 t/m2
Modulus of Elasticity (Strands) 1.95E+07 t/m2
Total Relaxation Loss at service condition (cl: 6.3.6 IRC 112) = 3 x (1000 hr. value)
Initial force after Friction, slip & ES loss = 820.93 t
Percentage of Initial force = 0.6850 UTS
Relaxation Loss at 1000hr. for low relaxation steel = 2.31 % of initial stress
Relaxation Loss at 1000hr. for low relaxation steel = 5.63 t/Cable
Immediate Loss i.e 1 hr. of stressing (Table 6.3 IRC:112) = 34 % of Total Loss
7 - 28 days Loss = 90 % of Total Loss
28 - 90 days Loss = 100 % of Total Loss
90 - a days Loss = 200 % of Total Loss
Immediate Loss i.e 1 hr. of stressing = 1.92 t/Cable
7 - 28 days Loss = 3.16 t/Cable
28 - 90 days Loss = 0.56 t/Cable
90 - a days Loss = 11.27 t/Cable
Strain due to differential shrinkage and creep 1.00E-04
Reduction factor due to differential creep 0.43
PSC BEAM AND RC SLAB STRUCTURE OF SIMPLY SUPPORTED SPAN
(INNER GIRDER)
Item Unit 1 2 3 4 5
MEMBER NO
distance of Section from left support m 2.000 4.000 6.090 12.180 16.970
SIDL
Moments Tm 23.5 42.1 87.0 141.3 191.3
Shear T 11.2 10.6 11.4 11.8 10.7
Live Load (Sagging) (max Moment Case & max Positive Shear case)
Moments Tm 129.2 203.6 292.8 318.8 293.9
Shear T 50.0 40.9 28.8 31.1 41.4
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Area of the section m 1.8142 1.38808125 0.96196 0.961963 0.9619625
Depth of the section m 2.500 2.500 2.500 2.500 2.500
CG of section from bottom m 1.2752406 1.255953054 1.23667 1.236665 1.236665476
4
Inertia of section m 0.9769032 0.838329327 0.69976 0.699755 0.699755494
3
Top Section Modulus m 0.7976 0.6739 0.5539 0.5539 0.5539
3
Bottom Section Modulus m 0.7661 0.6675 0.5658 0.5658 0.5658
2
Area of the section m 2.51 2.084 1.658 1.658 1.658
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.757873453 1.817 1.817 1.817
4
Inertia of section m 1.89 1.683 1.476 1.476 1.476
3
Top Section Modulus m 1.8151 1.7136 1.5991 1.5991 1.5991
3
Bottom Section Modulus m 1.1126 0.9574 0.8123 0.8123 0.8123
2
Area of the section m 2.51 2.084 1.658 1.658 1.658
Depth of the section m 2.740 2.740 2.740 2.740 2.740
CG of section from bottom m 1.6987469 1.757873453 1.817 1.817 1.817
4
Inertia of section m 1.89 1.683 1.476 1.476 1.476
3
Top Section Modulus m 1.8151 1.7136 1.5991 1.5991 1.5991
3
Bottom Section Modulus m 1.1126 0.9574 0.8123 0.8123 0.8123
For Cable 1b
No of Tendons of 19T13 0.95 0.95 0.95 0.95 0.95
Prestressing Force (P1) T 227.20 228.23 239.84 242.34 240.31
CG of Tendons from Bottom m 0.6629 0.4950 0.1203 0.1200 0.1200
Eccentricity of Tendons m 0.6123 0.7609 1.1163 1.1167 1.1167
Prestressing Factor (Top) -0.2165 -0.4088 -0.9759 -0.9765 -0.9765
Prestressing Factor (Bottom) 1.3505 1.8604 3.0124 3.0130 3.0130
For Cable 1c
No of Tendons of 19T13 0.95 0.95 0.95 0.95 0.95
Prestressing Force (P1) T 232.52 233.54 236.08 244.20 244.69
CG of Tendons from Bottom m 1.0200 0.7996 0.2516 0.1200 0.1200
Eccentricity of Tendons m 0.2552 0.4563 0.9851 1.1167 1.1167
Prestressing Factor (Top) 0.2313 0.0433 -0.7389 -0.9765 -0.9765
Prestressing Factor (Bottom) 0.8843 1.4041 2.7805 3.0130 3.0130
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
For Cable 1d
No of Tendons of 19T13 0.53 0.53 0.53 0.53 0.53
Prestressing Force (P1) T 129.77 130.34 131.75 136.34 135.89
CG of Tendons from Bottom m 1.4170 1.1929 0.6355 0.3000 0.3000
Eccentricity of Tendons m -0.1418 0.0631 0.6011 0.9367 0.9367
Prestressing Factor (Top) 0.7289 0.6268 -0.0457 -0.6515 -0.6515
Prestressing Factor (Bottom) 0.3662 0.8150 2.1019 2.6949 2.6949
For Cable 1e
No of Tendons of 19T13 0.00 0.00 0.00 0.00 0.00
Prestressing Force (P1) T 0.00 0.00 0.00 0.00 0.00
CG of Tendons from Bottom m 0.0000 0.0000 0.0000 0.0000 0.0000
Eccentricity of Tendons m 1.2752 1.2560 1.2367 1.2367 1.2367
Prestressing Factor (Top) -1.0476 -1.1434 -1.1931 -1.1931 -1.1931
Prestressing Factor (Bottom) 2.2159 2.6020 3.2251 3.2251 3.2251
Dead Load Moments - Ist stage Tm 76.10 146.00 258.00 334.00 355.00
Eloss of cable (1a) for stressing of (1a) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1a) for stressing of (1b) T 6.89 6.89 6.89 6.89 6.89
Eloss of cable (1a) for stressing of (1c) T 6.37 6.37 6.37 6.37 6.37
Eloss of cable (1a) for stressing of (1d) T 2.89 2.89 2.89 2.89 2.89
Eloss of cable (1a) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1b) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1b) for stressing of (1c) T 6.29 6.29 6.29 6.29 6.29
Eloss of cable (1b) for stressing of (1d) T 2.89 2.89 2.89 2.89 2.89
Eloss of cable (1b) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1c) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1c) for stressing of (1d) T 2.84 2.84 2.84 2.84 2.84
Eloss of cable (1c) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1d) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1d) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Eloss of cable (1e) for stressing of (1e) T 0.00 0.00 0.00 0.00 0.00
Total Eloss for Stage 1 cables T 28.17 28.17 28.17 28.17 28.17
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Stress at CG of cable 1a T/m 798.54 1144.30 1854.02 1910.05 1870.53
2
Stress at CG of cable 1b T/m 668.95 971.36 1853.74 1910.05 1870.53
2
Stress at CG of cable 1c T/m 550.26 826.87 1741.43 1910.05 1870.53
2
Stress at CG of cable 1d T/m 418.34 640.34 1412.93 1749.81 1716.29
2
Stress at CG of cable 1e T/m 889.26 1206.17 1956.69 2016.88 1973.35
2
Stress at CG of Stage 1 Cables T/m 594.33 869.71 1654.36 1777.61 1739.06
2
T/m
2
Average Stress at CG of Stage 1 Cables T/m 1534.70
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Dead Load Moments -IInd stage Tm 58.96 110.96 197.50 258.56 279.55
Stress Due to dead load
2
Top T/m 73.92 164.65 356.56 466.80 504.69
2
Bottom T/m -76.96 -166.23 -349.03 -456.95 -494.04
2
Stress at CG of GR I Tendons T/m -30.06 -88.02 -282.10 -402.10 -434.76
2
Stress at CG of GR II Tendons T/m 2643.11 -164.91 -346.21 -453.25 -490.04
Stresses due to C + S + R
2
Top T/m 1.22 2.15 4.12 4.71 4.71
2
T/m -0.04 0.37 1.37 1.81 1.81
2
Bottom T/m -13.24 -18.18 -27.27 -28.45 -28.45
2
Stress at CG of Tendon I T/m 549.49 755.05 1305.43 1292.48 1218.66
2
Average Stress at CG of Tendon GRI T/m 1161.16
2
Stress at CG of Gr I Tendons T/m -11.46 -29.19 -93.12 -159.74 -216.26
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Stress at CG of Tendon I T/m 449.88 592.24 974.49 874.68 744.32
2
Avg stress for each segment T/m 521.06 783.36 924.58 809.50 0.00
Segment length m 2.00 2.09 6.09 4.79 -16.97
length m 14.97
2
Average Stress at CG of Tendon GRI T/m 814.13
Moment Due to Live Load (Sagging) Tm 129.23 203.58 292.80 318.79 293.93
Stresses due to Live Load (Sagging)
2
Top of Deck Slab T/m 71.20 118.80 183.10 199.35 183.81
2
Top of Girder T/m 54.79 89.77 135.49 147.51 136.01
2
Bottom T/m -116.16 -212.64 -360.45 -392.44 -361.84
Stress at service with differential shrinkage and differential creep effect (without Live Load)
Top of Deck Slab T/m2 13.40 22.91 51.75 78.37 105.79
2
Top of Girder T/m 189.14 292.43 383.28 527.43 636.61
2
Bottom T/m 567.48 685.05 1036.45 896.60 751.12
Stress at service with differential shrinkage and differential creep effect (with 75% Live Load)
2
Top of Deck Slab T/m 66.80 112.01 189.07 227.88 243.65
2
Top of Girder T/m 230.23 359.76 484.90 638.07 738.62
2
Bottom T/m 480.36 525.57 766.11 602.27 479.74
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
Stress at Service with 75% Live Load (sag) + Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m -145.61 -100.40 398.75 437.56 453.32
2
Top of Girder T/m 357.83 487.36 352.54 505.72 606.27
2
Bottom T/m 324.35 369.56 896.30 732.46 609.93
Stress at Service with 100% Live Load (sag) + 60% Temp rise (RARE COMBINATION)
2
Top of Deck Slab T/m -42.85 14.26 360.65 403.53 415.41
2
Top of Girder T/m 320.49 458.76 439.36 595.54 693.21
2
Bottom T/m 357.72 378.80 754.12 582.27 467.39
Stress at Service with 75% Live Load (sag) + 50% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -39.41 5.80 293.91 332.72 348.49
2
Top of Girder T/m 294.03 423.56 418.72 571.90 672.45
2
Bottom T/m 402.36 447.56 831.21 667.36 544.83
Stress at Service with 20% Live Load (sag) + 60% Temp rise (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -99.81 -80.78 214.17 244.05 268.36
2
Top of Girder T/m 276.66 386.95 330.97 477.53 584.40
2
Bottom T/m 450.64 548.91 1042.47 896.22 756.86
Stress at Service with 100% Live Load (sag) +60 % Temp Fall (RARE COMBINATION)
2
Top of Deck Slab T/m -93.36 -36.25 47.18 90.05 101.93
2
Top of Girder T/m 192.54 330.82 457.46 613.64 711.32
2
Bottom T/m 383.93 405.01 596.55 424.70 309.82
Stress at Service with 75% Live Load (sag) + 50% Temp Fall (FREQUENT COMBINATION)
2
Top of Deck Slab T/m -81.50 -36.29 32.68 71.49 87.25
2
Top of Girder T/m 187.41 316.94 433.81 586.98 687.53
2
Bottom T/m 424.20 469.40 699.90 536.06 413.52
Stress at Service with 20% Live Load (sag) + 60% TempFall (FREQUENT COMBINATION)
Top of Deck Slab T/m2 -150.32 -131.29 -99.30 -69.43 -45.12
2
Top of Girder T/m 148.71 259.00 349.07 495.63 602.51
2
Bottom T/m 476.85 575.12 884.90 738.65 599.29
Item Unit 1 2 3 4 5
Chainage of Section from left support m 2.000 4.000 6.090 12.180 16.970
2
Minimum Stress = -208.67 t/m < -350 t/m2
After Stage 2
2 2
Maximum Stress = 1434.96 t/m < 2400 t/m
2 2
Minimum Stress = 179.79 t/m < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (without Live Load)
2 2
Maximum Stress = 1036.45 t/m < 2400 t/m
2
Minimum Stress = 189.14 < 2400 t/m
Stress at service with differential shrinkage and differential creep effect (with Live Load)
2 2
Maximum Stress = 772.63 t/m < 2400 t/m
2 2
Minimum Stress = 243.93 t/m < 2400 t/m
Stress at Service with Live Load (sag) + Temp Rise (FREQUENT COMBINATION)
2
Maximum Stress = 1042.47 t/m < 1800 t/m2
2 2
Minimum Stress = 276.66 t/m < -350 t/m
2 2
Minimum Stress = 148.71 t/m < -350 t/m
Stress at Service with Live Load (sag) + Temp Rise (Rare COMBINATION)
2 2
Maximum Stress = 896.30 t/m < 2400 t/m
2 2
Minimum Stress = 320.49 t/m < -350 t/m
2 2
Minimum Stress = 144.59 t/m < -350 t/m
Table 5.1.2 Ultimate forces at Sections:- Ultimate Force = 1.35xDL+1.75xSIDL+1.5xLL
fb = 41.44 N/mm2
2Ypo = 345 mm
Ypo/Yo = 0.69
Fbst/Pk = 0.124
Fbst = 0.12x2043.49
253.39 kN
701.82088 mm2
16 dia helix with 13 turns in 2Y0 region provided (Ast) 2613.805 mm2
Check for shear in flanged portion As per IRC: 112-2011 Clause 10.3.5.
Diffrence in stress (t/m2) 57.11
Length Ϫx (m) 2
θf 30
cotθf 1.73
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 5428.672 mm /m
2
Area of the interface = 228000 mm2 ; Area of interface reinforcement: 3619.115 mm /m
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 3500 MPa As per IRC112-2011,Table No.-6.5
fctm = Mean value of axial tensile strength of concrete = 3.5 MPa As per IRC112-2011,Table No.-6.5
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 3.5
k= 1
Kc = 0.4
Act =0.5bd = 31640.63 mm2 (considering without reinforcement)
=
As.min 88.59375 mm2
Reinfoecement provided = 678.24 mm2 ok
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 3500 MPa As per IRC112-2011,Table No.-6.5
fctm = Mean value of axial tensile strength of concrete = 3.5 MPa As per IRC112-2011,Table No.-6.5
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 3.5
k= 1
Kc = 0.4
Act =0.5bd = 36975 mm2 (considering without reinforcement)
=
As.min 103.53 mm2
Reinfoecement provided = 226.08 mm2 ok
Minimum Reinfocement for crack control in WEB at mid section
Grade of concrete M 50
Grade of steel Fe 500
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 3500 MPa As per IRC112-2011,Table No.-6.5
fctm = Mean value of axial tensile strength of concrete = 3.5 MPa As per IRC112-2011,Table No.-6.5
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 3.5
k= 1
Kc = 0.4
Act =0.5bd = 343750 mm2 (considering without reinforcement)
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 3500 MPa As per IRC112-2011,Table No.-6.5
fctm = Mean value of axial tensile strength of concrete = 3.5 MPa As per IRC112-2011,Table No.-6.5
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 3.5
k= 1
Kc = 0.4
Act =0.5bd = 887500 mm2 (considering without reinforcement)
=
As.min 2485 mm2
Reinfoecement provided = 2939.04 mm2 ok
DESIGN OF CROSS GIRDER
ULS BASIC SLS RARE SLS QUASI
Intermediate Cross Girder DL 1.35 1 1
SIDL OTHERS 1.35 1 1
SIDL WC 1.750 1 1
LL 1.500 1 0
3.13 m 3.13 m Impact foctor 1.12
A B (SKW) C
UNFACORED ULS SLS RARE SLS QUASI
From STAAD output T-m T-m T-m T-m
= HOG 4.70 6.35 4.70 4.70
Max moment (DL)
= SAG 1.72 2.32 1.72 1.72
= HOG 68.50 92.48 68.50 68.50
Max Hogging moment (SIDL OTHERS)
= SAG 0.00 0.00 0.00 0.00
= HOG 0.03 0.05 0.03 0.03
Max Hogging moment (SIDL WC)
= SAG 0.50 0.88 0.50 0.50
Max Hogging Moment due to Footpath live load = HOG 0.00 0.00 0.00 0.00
only = SAG 0.00 0.00 0.00 0.00
Max Hogging Moment due to live load only = HOG 87.30 130.95 87.30 0.00
Max Sagging Moment due to live load only = SAG 145.00 217.5 145 0
Live Load Hogging Moment-Including Impact = HOG 97.78 146.66 97.78 0.00
Live Load Sagging Moment-Including Impact = SAG 162.40 243.60 162.40 0.00
Total Hogging moment (at top) = HOG 171.01 245.54 171.01 73.23
Total Sagging moment (at bottom) = SAG 164.62 246.80 164.62 2.22
2
Required Ast at top =Mu/(0.87*fy*Z) =171.01*10000/(0.87*500*100*1.3754) = 41.04 cm
2
i.e. 15.41 cm
2
In Next 0.6*D depth rest of the reinforcement will be distributed equally i.e. 25.63 cm
2
Provided Ast at bottom = 44.18 cm Thus OK
Minimum embedment from bottom face with a development length of (0.8*30*dia of bar)
= 600 mm
2
Required Ast per m length =16.8/3.127 = 10.77 cm /m
0.1 % of web area on either face with spacing not more then 450 mm.
2
Provided Ast = 11.00 cm
Thus OK
STRESS CHECK FOR SLS COMBINATION
The end cross girder is designed as a continuous deep beam for bearing replacement condition, continuous over knife supports at the jack locations.
The center line of jacks are taken to be 800 (SQ) mm from the center line of main girders.
Required Ast for max span Moment =Mu/(0.87*fy*Z) =0*10000/(0.87*500*100*1.62) = 0.00 cm2
=Mu/(0.87*fy*Z)
2
Required Ast for max support Moment =615*10000/(0.87*500*100*1.62) = 87 cm
2
In Next 0.6*D depth rest of the reinforcement will be distributed equally i.e. 58.28 cm
2
Required Ast per m width =38.4/0.863 = 44.5 cm /m
2
Provided Ast = 40.2 cm /m
Thus Not OK
0.1 % of web area on either face with spacing not more then 450 mm.
2
Provided Ast = 28.15 cm
Thus OK
STAAD INPUT FOR END CROSS GIRDER
STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 03-Nov-15
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER MTON
JOINT COORDINATES
1 9.1686 0 -23.2; 2 7.9969 0 -20.3; 3 6.8252 0 -17.4; 4 5.6535 0 -14.5;
5 4.4818 0 -11.6; 6 3.3101 0 -8.7; 7 2.1384 0 -5.8; 8 0.9667 0 -2.9;
9 -0.205 0 0; 10 9.9866 0 -25.225; 11 -1.023 0 2.025;
12 8.84538 0 -22.4; 13 7.67368 0 -19.5; 14 6.50198 0 -16.6;
15 5.33028 0 -13.7; 16 4.15858 0 -10.8; 17 2.98688 0 -7.90003;
18 1.81518 0 -5.00003; 19 0.643484 0 -2.10003; 20 8.32014 0 -21.1;
21 7.14844 0 -18.2; 22 5.97674 0 -15.3; 23 4.80504 0 -12.4;
24 3.63334 0 -9.50003; 25 2.46164 0 -6.60003; 26 1.28994 0 -3.70003;
27 0.118239 0 -0.800027;
MEMBER INCIDENCES
1 1 12; 2 2 13; 3 3 14; 4 4 15; 5 5 16; 6 6 17; 7 7 18; 8 8 19; 9 10 1;
10 9 11; 11 12 20; 12 13 21; 13 14 22; 14 15 23; 15 16 24; 16 17 25;
17 18 26; 18 19 27; 19 20 2; 20 21 3; 21 22 4; 22 23 5; 23 24 6;
24 25 7; 25 26 8; 26 27 9;
DEFINE MATERIAL START
ISOTROPIC CONCRETE
E 2.21467e+006
POISSON 0.17
DENSITY 2.40262
ALPHA 1e-005
DAMP 0.05
TYPE CONCRETE
STRENGTH FCU 2812.28
END DEFINE MATERIAL
MEMBER PROPERTY
1 TO 26 PRIS YD 1 ZD 1
CONSTANTS
MATERIAL CONCRETE ALL
SUPPORTS
10 11 PINNED
LOAD 1 LOADTYPE None TITLE 1.35 DL+1.35 SIDL CB+1.75SIDL WC
JOINT LOAD
1 9 FY -167.5
2 TO 8 FY -161
12 TO 27 FY 91.4
***
LOAD 2 LOADTYPE None TITLE 1.0 DL+1.0 SIDL CB+1.0SIDL WC
JOINT LOAD
1 9 FY -121
2 TO 8 FY -117
12 TO 27 FY 66.3
PERFORM ANALYSIS
FINISH
Transverse analysis
Staad Input
STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 01-Dec-09
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER MTON
JOINT COORDINATES
1 0 0 0; 2 27.25 0 0; 3 2.025 0 0; 4 4.925 0 0; 5 7.825 0 0; 6 10.725 0 0;
7 13.625 0 0; 8 16.525 0 0; 9 19.425 0 0; 10 22.325 0 0; 11 25.225 0 0;
12 2.5 0 0; 13 5.4 0 0; 14 8.3 0 0; 15 11.2 0 0; 16 14.1 0 0; 17 17 0 0;
18 19.9 0 0; 19 22.8 0 0; 20 25.7 0 0; 21 4.45 0 0; 22 7.35 0 0; 23 10.25 0 0;
24 13.15 0 0; 25 16.05 0 0; 26 18.95 0 0; 27 21.85 0 0; 28 24.75 0 0;
29 1.55 0 0; 30 4.26 0 0; 31 7.16 0 0; 32 10.06 0 0; 33 12.96 0 0;
34 15.86 0 0; 35 18.76 0 0; 36 21.66 0 0; 37 24.56 0 0; 38 2.69 0 0;
39 5.59 0 0; 40 8.49 0 0; 41 11.39 0 0; 42 14.29 0 0; 43 17.19 0 0;
44 20.09 0 0; 45 22.99 0 0;
MEMBER INCIDENCES
1 1 29; 2 3 12; 3 4 13; 4 5 14; 5 6 15; 6 7 16; 7 8 17; 8 9 18; 9 10 19;
10 11 20; 11 12 38; 12 13 39; 13 14 40; 14 15 41; 15 16 42; 16 17 43; 17 18 44;
18 19 45; 19 20 2; 20 21 4; 21 22 5; 22 23 6; 23 24 7; 24 25 8; 25 26 9;
26 27 10; 27 28 11; 28 29 3; 29 30 21; 30 31 22; 31 32 23; 32 33 24; 33 34 25;
34 35 26; 35 36 27; 36 37 28; 37 38 30; 38 39 31; 39 40 32; 40 41 33; 41 42 34;
42 43 35; 43 44 36; 44 45 37;
START GROUP DEFINITION
MEMBER
_DEFF 37 TO 44
END GROUP DEFINITION
DEFINE MATERIAL START
ISOTROPIC CONCRETE
E 2.21466e+006
POISSON 0.17
DENSITY 2.5
ALPHA 5.5e-006
DAMP 0.05
END DEFINE MATERIAL
MEMBER PROPERTY AMERICAN
1 TO 44 PRIS YD 0.24 ZD 1
CONSTANTS
MATERIAL CONCRETE ALL
SUPPORTS
3 TO 11 PINNED
LOAD 1
MEMBER LOAD
37 UNI GY -18.71 0 0.2
11 UNI GY -18.71 0 0.19
2 UNI GY -18.71 0 0.475
28 UNI GY -18.71 0 0.475
1 UNI GY -18.71 1.43 1.55
20 UNI GY -7.9 0 0.37
29 UNI GY -7.9 0 0.19
37 UNI GY -7.9 0.67 1.57
LOAD 2
MEMBER LOAD
37 UNI GY -8.79 0 0.7
11 UNI GY -8.79 0 0.19
2 UNI GY -8.79 0 0.475
28 UNI GY -8.79 0.38 0.475
3 UNI GY -10.36 0 0.395
20 UNI GY -10.36 0 0.475
29 UNI GY -10.36 0 0.19
37 UNI GY -10.36 1.17 1.57
LOAD 3
MEMBER LOAD
37 UNI GY -7.41 0 1.2
11 UNI GY -7.41 0 0.19
2 UNI GY -7.41 0.405 0.475
38 UNI GY -16.9 0 0.23
12 UNI GY -16.9 0 0.19
3 UNI GY -16.9 0 0.475
20 UNI GY -16.9 0 0.475
29 UNI GY -16.9 0.1 0.19
LOAD 4
MEMBER LOAD
29 UNI GY -7.24 0 0.13
37 UNI GY -7.24 0.24 1.57
38 UNI GY -8.65 0 0.73
12 UNI GY -8.65 0 0.19
3 UNI GY -8.65 0 0.475
20 UNI GY -8.65 0.41 0.475
LOAD 5
MEMBER LOAD
20 UNI GY -8.1 0 0.44
29 UNI GY -8.1 0 0.19
37 UNI GY -8.1 0.74 1.57
38 UNI GY -7.37 0 1.23
12 UNI GY -7.37 0 0.19
3 UNI GY -7.37 0.435 0.475
LOAD 6
MEMBER LOAD
3 UNI GY -11.66 0 0.465
20 UNI GY -11.66 0 0.475
29 UNI GY -11.66 0 0.19
37 UNI GY -11.66 1.24 1.57
30 UNI GY -7.26 0 0.16
38 UNI GY -7.26 0.27 1.57
LOAD 7
MEMBER LOAD
38 UNI GY -13.9 0 0.3
12 UNI GY -13.9 0 0.19
3 UNI GY -13.9 0 0.475
20 UNI GY -13.9 0 0.475
29 UNI GY -13.9 0.17 0.19
21 UNI GY -8.19 0 0.47
30 UNI GY -8.19 0 0.19
38 UNI GY -8.19 0.77 1.57
LOAD 8
MEMBER LOAD
38 UNI GY -8.37 0 0.8
12 UNI GY -8.37 0 0.19
3 UNI GY -8.37 0.00499964 0.475
13 UNI GY -12.4 0 0.0199995
4 UNI GY -12.4 0 0.475
21 UNI GY -12.4 0 0.475
30 UNI GY -12.4 0 0.19
38 UNI GY -12.4 1.27 1.57
LOAD 9
MEMBER LOAD
38 UNI GY -7.3 0 1.3
12 UNI GY -7.3 0.0299997 0.19
39 UNI GY -12.95 0 0.33
13 UNI GY -12.95 0 0.19
4 UNI GY -12.95 0 0.475
21 UNI GY -12.95 0.0100002 0.475
LOAD 10
MEMBER LOAD
21 UNI GY -7.32 0 0.04
30 UNI GY -7.32 0 0.19
38 UNI GY -7.32 0.34 1.57
39 UNI GY -8.26 0 0.83
13 UNI GY -8.26 0 0.19
4 UNI GY -8.26 0.0349998 0.475
LOAD 11
MEMBER LOAD
4 UNI GY -8.45 0 0.0649996
21 UNI GY -8.45 0 0.475
30 UNI GY -8.45 0 0.19
38 UNI GY -8.45 0.84 1.57
39 UNI GY -7.27 0 1.33
13 UNI GY -7.27 0.0599995 0.19
LOAD 12
MEMBER LOAD
13 UNI GY -14.63 0 0.0900002
4 UNI GY -14.63 0 0.475
21 UNI GY -14.63 0 0.475
30 UNI GY -14.63 0 0.19
38 UNI GY -14.63 1.34 1.57
22 UNI GY -7.35 0 0.0700002
31 UNI GY -7.35 0 0.19
39 UNI GY -7.35 0.369999 1.57
LOAD 13
MEMBER LOAD
39 UNI GY -11.23 0 0.4
13 UNI GY -11.23 0 0.19
4 UNI GY -11.23 0 0.475
21 UNI GY -11.23 0.0799999 0.475
5 UNI GY -8.57 0 0.0949998
22 UNI GY -8.57 0 0.475
31 UNI GY -8.57 0 0.19
39 UNI GY -8.57 0.87 1.57
LOAD 14
MEMBER LOAD
39 UNI GY -8.04 0 0.9
13 UNI GY -8.04 0 0.19
4 UNI GY -8.04 0.105 0.475
14 UNI GY -15.9 0 0.119999
5 UNI GY -15.9 0 0.475
22 UNI GY -15.9 0 0.475
31 UNI GY -15.9 0 0.19
39 UNI GY -15.9 1.37 1.57
LOAD 15
MEMBER LOAD
39 UNI GY -7.22 0 1.4
13 UNI GY -7.22 0.13 0.19
40 UNI GY -10.65 0 0.429999
14 UNI GY -10.65 0 0.19
5 UNI GY -10.65 0 0.475
22 UNI GY -10.65 0.109999 0.475
LOAD 16
MEMBER LOAD
22 UNI GY -7.44 0 0.14
31 UNI GY -7.44 0 0.19
39 UNI GY -7.44 0.44 1.57
40 UNI GY -7.95 0 0.93
14 UNI GY -7.95 0 0.19
5 UNI GY -7.95 0.134999 0.475
LOAD 17
MEMBER LOAD
5 UNI GY -8.88 0 0.164999
22 UNI GY -8.88 0 0.475
31 UNI GY -8.88 0 0.19
39 UNI GY -8.88 0.94 1.57
40 UNI GY -7.21 0 1.43
14 UNI GY -7.21 0.159998 0.19
LOAD 18
MEMBER LOAD
14 UNI GY -20.17 0 0.189999
5 UNI GY -20.17 0 0.475
22 UNI GY -20.17 0 0.475
31 UNI GY -20.17 0 0.19
39 UNI GY -20.17 1.44 1.57
23 UNI GY -7.48 0 0.17
32 UNI GY -7.48 0 0.19
40 UNI GY -7.48 0.469998 1.57
LOAD 19
MEMBER LOAD
40 UNI GY -9.97 0 0.499999
14 UNI GY -9.97 0 0.19
5 UNI GY -9.97 0 0.475
22 UNI GY -9.97 0.180001 0.475
6 UNI GY -9.03 0 0.195001
23 UNI GY -9.03 0 0.474999
32 UNI GY -9.03 0 0.19
40 UNI GY -9.03 0.97 1.57
LOAD 20
MEMBER LOAD
40 UNI GY -7.77 0 1
14 UNI GY -7.77 0 0.19
5 UNI GY -7.77 0.205 0.475
41 UNI GY -22.9 0 0.0300004
15 UNI GY -22.9 0 0.19
6 UNI GY -22.9 0 0.475
23 UNI GY -22.9 0 0.474999
32 UNI GY -22.9 0 0.19
40 UNI GY -22.9 1.47 1.57
LOAD 21
MEMBER LOAD
40 UNI GY -7.19 0.0400004 1.5
41 UNI GY -9.75 0 0.53
15 UNI GY -9.75 0 0.19
6 UNI GY -9.75 0 0.475
23 UNI GY -9.75 0.209999 0.474999
LOAD 22
MEMBER LOAD
24 UNI GY -7.82 0 0.34
33 UNI GY -7.82 0 0.19
41 UNI GY -7.82 0.640001 1.57
42 UNI GY -7.51 0 1.13
16 UNI GY -7.51 0 0.190001
7 UNI GY -7.51 0.335002 0.475
LOAD 29
MEMBER LOAD
7 UNI GY -10.12 0 0.365001
24 UNI GY -10.12 0 0.474998
33 UNI GY -10.12 0 0.19
41 UNI GY -10.12 1.14 1.57
34 UNI GY -7.2 0 0.0599998
42 UNI GY -7.2 0.170001 1.57
LOAD 30
MEMBER LOAD
42 UNI GY -18.71 0 0.2
16 UNI GY -18.71 0 0.190001
7 UNI GY -18.71 0 0.475
24 UNI GY -18.71 0 0.474998
33 UNI GY -18.71 0.0699998 0.19
25 UNI GY -7.9 0 0.370001
34 UNI GY -7.9 0 0.19
42 UNI GY -7.9 0.670001 1.57
LOAD 31
MEMBER LOAD
42 UNI GY -8.79 0 0.7
16 UNI GY -8.79 0 0.190001
7 UNI GY -8.79 0 0.475
24 UNI GY -8.79 0.380001 0.474998
8 UNI GY -10.36 0 0.395002
25 UNI GY -10.36 0 0.474998
34 UNI GY -10.36 0 0.19
42 UNI GY -10.36 1.17 1.57
LOAD 32
MEMBER LOAD
42 UNI GY -7.41 0 1.2
16 UNI GY -7.41 0 0.190001
7 UNI GY -7.41 0.405002 0.475
43 UNI GY -16.9 0 0.230001
17 UNI GY -16.9 0 0.190001
8 UNI GY -16.9 0 0.475
25 UNI GY -16.9 0 0.474998
34 UNI GY -16.9 0.0999998 0.19
LOAD 33
MEMBER LOAD
34 UNI GY -7.24 0 0.13
42 UNI GY -7.24 0.240001 1.57
43 UNI GY -8.65 0 0.730001
17 UNI GY -8.65 0 0.190001
8 UNI GY -8.65 0 0.475
25 UNI GY -8.65 0.410002 0.474998
LOAD 34
MEMBER LOAD
25 UNI GY -8.1 0 0.440001
34 UNI GY -8.1 0 0.19
42 UNI GY -8.1 0.740001 1.57
43 UNI GY -7.37 0 1.23
17 UNI GY -7.37 0 0.190001
8 UNI GY -7.37 0.435003 0.475
LOAD 35
MEMBER LOAD
8 UNI GY -11.66 0 0.465002
25 UNI GY -11.66 0 0.474998
34 UNI GY -11.66 0 0.19
42 UNI GY -11.66 1.24 1.57
35 UNI GY -7.26 0 0.16
43 UNI GY -7.26 0.270002 1.57
LOAD 36
MEMBER LOAD
43 UNI GY -13.9 0 0.300001
17 UNI GY -13.9 0 0.190001
8 UNI GY -13.9 0 0.475
25 UNI GY -13.9 0 0.474998
34 UNI GY -13.9 0.17 0.19
26 UNI GY -8.19 0 0.470001
35 UNI GY -8.19 0 0.19
43 UNI GY -8.19 0.770002 1.57
LOAD 37
MEMBER LOAD
43 UNI GY -8.37 0 0.800001
17 UNI GY -8.37 0 0.190001
8 UNI GY -8.37 0.00500298 0.475
18 UNI GY -12.4 0 0.0200024
9 UNI GY -12.4 0 0.475
26 UNI GY -12.4 0 0.474998
35 UNI GY -12.4 0 0.19
43 UNI GY -12.4 1.27 1.57
LOAD 38
MEMBER LOAD
43 UNI GY -7.3 0 1.3
17 UNI GY -7.3 0.0300026 0.190001
44 UNI GY -12.95 0 0.330001
18 UNI GY -12.95 0 0.190001
9 UNI GY -12.95 0 0.475
26 UNI GY -12.95 0.0100021 0.474998
LOAD 39
MEMBER LOAD
26 UNI GY -7.32 0 0.0400009
35 UNI GY -7.32 0 0.19
43 UNI GY -7.32 0.340002 1.57
44 UNI GY -8.26 0 0.829999
18 UNI GY -8.26 0 0.190001
9 UNI GY -8.26 0.0350037 0.475
LOAD 40
MEMBER LOAD
9 UNI GY -8.45 0 0.0650024
26 UNI GY -8.45 0 0.474998
35 UNI GY -8.45 0 0.19
43 UNI GY -8.45 0.839999 1.57
44 UNI GY -7.27 0 1.33
18 UNI GY -7.27 0.0600033 0.190001
LOAD 41
MEMBER LOAD
18 UNI GY -14.63 0 0.0900021
9 UNI GY -14.63 0 0.475
26 UNI GY -14.63 0 0.474998
35 UNI GY -14.63 0 0.19
43 UNI GY -14.63 1.34 1.57
27 UNI GY -7.35 0 0.0700016
36 UNI GY -7.35 0 0.19
44 UNI GY -7.35 0.370002 1.57
LOAD 71 DEAD LOAD
SELFWEIGHT Y -1
LOAD 72 SIDL CRASH BARRIER
MEMBER LOAD
1 CON GY -1 0
19 CON GY -1 1.55
LOAD 73 SIDL WEARING COARSE
MEMBER LOAD
1 TO 44 UNI GY -0.2
PERFORM ANALYSIS
FINISH
Force Summary for intermediate span
SLSQUASI ULS BASIC SLS RARE
PERMANENTCOM COMB. COMB.
ULS BASIC COMB. SLS RARE COMB. B. (Favourable) (Favourable)
Factor
DL & SIDL 1.35 1 1 1
SURFACING 1.75 1.2 1.2 1 1
LIVE LOAD (LEADING) 1.5 1 0
(FOR ACCOMPANYING ) 1.15 0.75 0
2.025 m
Moment at the face of support due to live load =5.836*1.125 = 6.566 tm/m
Design forces
Grade of concrete M 35 ULS bending moment = 145 kNm (FACE OF SUPPORT)
Grade of steel Fe 500 ULS design shear force = 162 kN (at effective depth)
SLS bending moment = 97 kNm (RARE COMBINATION)
SLS design shear force = 109 kN (RARE COMBINATION) (at effective depth)
SLS bending moment =6 kNm (QUASI COMBINATION)
SLS design shear force = 10 kN (QUASI COMBINATION)
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 32000 MPa As per IRC112-2011,Table No.-6.5
Modular ratio = 15.00 Modular ratio = 6.25
Max strain in concrete = 0.0035 Min strain in steel = 0.0042
fctm = Mean value of axial tensile strength of concrete = 2.8 MPa As per IRC112-2011,Table No.-6.5
Minimum Area of Distribution steel 0.2% of R/F required for bending 414.164875
Area of Distribution steel provided 10 @ 150 c/c 523.60 mm2 Hence O.K.
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 2.9
k= 1
Kc = 0.4
Act =0.5bd = 120000 mm2 (considering without reinforcement)
=
As.min 278.4 mm2
Reinfoecement provided = 2234.02 mm2 ok
Design of slab AT SPAN
Design forces
Grade of concrete M 35 ULS bending moment = 102 kNm (FACE OF SUPPORT)
Grade of steel Fe 500 SLS bending moment = 69 kNm (RARE COMBINATION)
SLS bending moment =8 kNm (QUASI COMBINATION)
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 32000 MPa As per IRC112-2011,Table No.-6.5
Modular ratio = 15.00 Modular ratio = 6.25
Max strain in concrete = 0.0035 Min strain in steel = 0.0042
fctm = Mean value of axial tensile strength of concrete = 2.8 MPa As per IRC112-2011,Table No.-6.5
Minimum Area of Distribution steel 0.2% of R/F required for bending 270.982739
Area of Distribution steel provided 10 @ 150 c/c 523.60 mm2 Hence O.K.
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 2.9
k= 1
Kc = 0.4
Act =0.5bd = 120000 mm2 (considering without reinforcement)
=
As.min 278.4 mm2
Reinfoecement provided = 1745.33 mm2 ok
Design of cantilever slab (transverse direction)
Design forces
Grade of concrete M 35 ULS bending moment = 149 kNm (FACE OF SUPPORT)
Grade of steel Fe 500 SLS bending moment = 103 kNm (RARE COMBINATION)
SLS bending moment = 37 kNm (QUASI COMBINATION)
Section dimensions Reinforcement details
Width of the section = 1000 mm Clear cover = 40 mm
Depth of the section = 240 mm Dia of transverse bars = 16 mm
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 32000 MPa As per IRC112-2011,Table No.-6.5
Modular ratio = 15.00 Modular ratio = 6.25
Max strain in concrete = 0.0035 Min strain in steel = 0.0042
fctm = Mean value of axial tensile strength of concrete = 2.8 MPa As per IRC112-2011,Table No.-6.5
Minimum Area of Distribution steel 0.2% of R/F required for bending 403.21873
Area of Distribution steel provided 10 @ 150 c/c 523.60 mm2 Hence O.K.
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 2.9
k= 1
Kc = 0.4
Act =0.5bd = 120000 mm2 (considering without reinforcement)
=
As.min 278.4 mm2
Reinfoecement provided = 2234.02 mm2 ok
DESIGN OF DECK SLAB BEYOND DIAPHRAGM :
20 t
0.400 m
0.916 m
0.36 m
0.263 m
Cantilever slab projection beyond diaphragm has been checked for 40t boggie load,for the wheel placing
as shown as above.
SPAN= 0.916m
= 6.57 t-m/m
= 0.420 t-m/m
= 0.06 t-m/m
= 0.42 t-m/m
Load case
MOMENT (kN-
m)
DL 4.20
SIDL CRASH BARRIER 4.20
SIDL W/C SURFACING 0.63
LIVE LOAD 65.7
vehicle max(+) LLMAX 65.69
FOR ULS BASIC COMBINATION B.M (kN-m)
DL+SIDL+LL 111.0
FOR SLS RARE COMBINATION B.M (kN-m)
DL+SIDL+LL 74.83
FOR SLS QUASI PERMANENT COMBINATION B.M (kN-m)
DL+SIDL 9.15
Design of cantilever slab (longitudinal direction)
Design forces
Grade of concrete M 35 ULS bending moment = 111 kNm (FACE OF SUPPORT)
Grade of steel Fe 500 SLS bending moment = 75 kNm (RARE COMBINATION)
SLS bending moment =9 kNm (QUASI COMBINATION)
Section dimensions Reinforcement details
Width of the section = 1000 mm Clear cover = 40 mm
Depth of the section = 400 mm Dia of transverse bars = 16 mm
Miscellaneous details
E of reinforcement = 200 GPa Ecm of concrete = 32000 MPa As per IRC112-2011,Table No.-6.5
Modular ratio = 15.00 Modular ratio = 6.25
Max strain in concrete = 0.0035 Min strain in steel = 0.0042
fctm = Mean value of axial tensile strength of concrete = 2.8 MPa As per IRC112-2011,Table No.-6.5
Minimum Area of Distribution steel 0.2% of R/F required for bending 149.467776
Area of Distribution steel provided 10 @ 150 c/c 523.60 mm2 Hence O.K.
σs = fyk = Fe 500
fct,eff = max(fctm ,2.9) = 2.9
k= 1
Kc = 0.4
Act =0.5bd = 200000 mm2 (considering without reinforcement)
=
As.min 464 mm2
Reinfoecement provided = 1340.41 mm2 ok